New North
Server
Room
Rm
South
Office
Addition
21 3
Generator External NEMA
Enclosure 1
External NEMA
Enclosure 2
External NEMA
Enclosure 3
External NEMA
Enclosure 4
UNCLASS
Comm
N
Mech
RoomNEMA
Enclosure
SECURE
NEMA
Enclosure
UNCLASS
Internal
NEMA 1
Internal
NEMA 2
Internal
NEMA 3
Internal
NEMA 4
Rm
Internal
NEMA 5
Diagram 1
Under raised floor cable trays
Under raised floor cable trays
Above ceiling space cable trays
Under raised floor cable trays
Comm
Handhole
Roof mount external NEMA enclosure
UNCLASSUNCLASS
30'-10 1/2"
/2
/2
4'-3"
26'-0"
/2
Power Requirements:
Racks 1-8 “EACH”
Qty 2: L530
Qty 2: L630
UPS Model:
HP R5500 VA 3U (L630P)
APC Smart-UPS XL 3000VA RM 3U
(L530P)
111111
1 1
NEMA 4
Wall 4x 115VAC1
Floor 4x 115VAC
NEMA 3NEMA 2
NEMA 1
Conduits to GCS pad
Data
Cabinets require 36" maintenance access on at least 2 sides, preferably all sides.
Diagram 2
Rm 106
6ft above raised floor
4x 115VAC
UNCLASS
Conduit leading thru
NEMA enclosure to roof top NEMA enclosure for radio antenna
4x CAT 6e STP Plenum
6x RG6 BNC
12str ST MM
4x CAT 6e STP Plenum
6x RG6 BNC
12str ST MM
6ft above raised floor
2x CAT 6e STP Plenum
2x RG6 BNC
4str ST MM
6ft above raised floor
2x CAT 6e STP Plenum
2x RG6 BNC
4str ST MM
Blue security light maryjo.wheeler Text Box New West Server Room
Floor 4x 115VAC
12 str Red ST MM
Terminate rack 3
3x CAT 6e plenum
6 str Green ST MM
Terminate rack 1
4 str Yellow SC MM
Terminate rack 2
6ft above raised floor
4x 115VAC
6ft above raised floor
2 str Red ST MM
Terminate rack 3
6ft above floor
2 str Green ST MM
Terminate rack 1
6ft above floor
2 str Yellow SC MM
Terminate rack 2
BLDG 703 South office addition
NS
E
W
6 7
N E
M A
B o x
13'-10 3/16" 36'-10 3/4"
Data Cabinets require 36" maintenance access on at least 2 sides, preferably 4.
Diagram 3
Blue security light
Storage Storage StorageStorage
Work Bench Work Bench
LN40C67 0
26'-0"
/2
LN40C67 0
55IN 1080P55IN 1080P 55IN 1080P
Additional Requirements:
Drop down projector screens will remain in place, existing projector audio/video cables routed to three single gang boxes.
Diagram 4 maryjo.wheeler Text Box Diagram 4 maryjo.wheeler Rectangle
| B703 Renovation Comm Plan 26May.vsd |
| B703 Site Plan |
| B703 Server Room & Rm106 Ops Floor |
| B703 South Office Addition |
| Ops Floor |