20100823 AB1141 091085 ANDERSON SWALE 12.18.09.pdf

PDF 724 KB Posted

Attached to
Restore CEMIRT Parking Area
Solicitation number
FA481921R0023
Issued by

About this file

This solicitation notice is for the Restore CEMIRT Parking Area contract at Tyndall Air Force Base, Florida. The contract will be a single award, firm-fixed price contract to provide all professional services, permits, equipment, labor, tools, materials, and ancillary items necessary to complete tasks defined in the Statement of Work. The period of performance is 365 calendar days after notice to proceed. The contractor must adhere to guidance including Unified Facilities Criteria 325-001, 325-003, and 36-0001 as well as Air Force standards, DOD directives, Florida statutes, FDOT requirements, Tyndall AFB regulations, and OSHA and EPA regulations. The North American Industry Classification System code is 238990 with a $16.5 million size standard. This requirement is set aside as a 100% Service-Disabled Veteran-Owned Small Business. The solicitation will be issued electronically on or about June 2, 2021 using the Lowest Price Technically Acceptable source selection procedure.

View the file

Other files

File Type Posted
Attachment 11 General Financial Info.pdf PDF
Attachment 5 AF Form 66.xls XLS spreadsheet
Attachment 3 SOW Appendix B.pdf PDF
Attachment 6 AF Form 3000.pdf PDF
Attachment 10 Other Contract Requirements.pdf PDF
Attachment 4 Wage Determination (Highway).pdf PDF
Attachment 8 AF 3065.pdf PDF
Attachment 7 AF 3064.pdf PDF
Attachment 9 Sample RFI.PDF PDF
Amendment FA481921R00230005 SF 30.pdf PDF
Attachment 1 SOW XLWU 208174 revised 29JUL21.pdf PDF
Amendment FA481921R00230004 SF 30.pdf PDF
Additional RFIs Answered.docx DOCX document
FA481921R00230003 SF 30.pdf PDF
Solicitation Amendment FA481921R00230002 SF 30.pdf PDF
20130430 - AB1142 Asbuilt Bldg 1142.pdf PDF
Amendment FA481921R00230001 SF 30.pdf PDF
AF Form 813 CEMIRT Facilities.pdf PDF
CEMIRT RFI Answers.xlsx XLSX spreadsheet
20071218 - AB1142 Xplan.pdf PDF
20100823 AB1141 091085 C1 2.pdf PDF
20110214 - AB1144 2012 May - Asbuilt Bldg 1144.pdf PDF
20100427 AB1141 Asbuilt Bldg 1141.pdf PDF
20100823 - AB1141 091085-E1.pdf PDF
20100823 AB1141 091085-A1.pdf PDF
20080116 AB1142 Asbuilt Bldg 1142.pdf PDF
Attachment 2 - SOW Appendix A - Revised 6-30-21.pdf PDF
Restore CEMIRT Parking Area.zip ZIP file
Synopsis CEMIRT Parking.docx DOCX document
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FDOT 1-hr Swale Treatment Rainfall=2.65"Swale Treatment Printed 12/17/2009Prepared by Anderson Engineers, P.A.

Page 1HydroCAD� 9.00 s/n 02740 � 2009 HydroCAD Software Solutions LLC

Time span=0.00-12.00 hrs, dt=0.05 hrs, 241 points Runoff by SCS TR-20 method, UH=SCS

Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method

Runoff Area=56,700 sf 66.49% Impervious Runoff Depth=0.89"Subcatchment 1S: MAAS Storage Pad Tc=10.0 min CN=78 Runoff=3.00 cfs 0.096 af

Peak Elev=0.74' Storage=0.096 af Inflow=3.00 cfs 0.096 afPond 1P: Treatment Swale Outflow=0.00 cfs 0.000 af

Total Runoff Area = 1.302 ac Runoff Volume = 0.096 af Average Runoff Depth = 0.89" 33.51% Pervious = 0.436 ac 66.49% Impervious = 0.865 ac

FDOT 1-hr Swale Treatment Rainfall=2.65"Swale Treatment Printed 12/17/2009Prepared by Anderson Engineers, P.A.

Page 2HydroCAD� 9.00 s/n 02740 � 2009 HydroCAD Software Solutions LLC

Summary for Subcatchment 1S: MAAS Storage Pad

Existing Site:

The existing site is cleared of trees and underbrush and is comprised of Resota Fine Sands with moderate established grass covering. No pre-development model or runoff totals were calculated since the proposed treatment facility will have no discharge offsite.

Proposed Drainage System:

The proposed concrete pad and immediate ground within the limits of construction denoted with silt fencing surrounding construction limits will be treated via swale system treatment. Off-site flows will temain undesturbed and will sheet drain south via the existing roadside drainage ditch system.

Design Guidelines:

Stormwater quantity treatment volumes were calculated based on FDOT rainfall 3 year / 1 hour distribution = 2.65 inches. per ERP AH Volumne II, Chapter 9

Runoff= 3.00 cfs @ 0.73 hrs, Volume= 0.096 af, Depth=0.89"

Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-12.00 hrs, dt= 0.05 hrs FDOT 1-hr Swale Treatment Rainfall=2.65"

Area (sf)CN Description

* 37,700 98CONCRETE PAD, HSG A

19,000 39>75% Grass cover, Good, HSG A 56,700 78Weighted Average 19,000 33.51% Pervious Area 37,700 66.49% Impervious Area

TcLength SlopeVelocityCapacityDescription (min)(feet)(ft/ft)(ft/sec) (cfs)

10.0 Direct Entry, Tc Min.

Subcatchment 1S: MAAS Storage Pad

Runoff

Hydrograph

Time (hours)

1211109876543210

F l o w c f s

FDOT

1-hr Swale Treatment

Rainfall=2.65"

Runoff Area=56,700 sf

Runoff Volume=0.096 af

Runoff Depth=0.89"

Tc=10.0 min

CN=78

3.00 cfs @ 0.73 hrs

FDOT 1-hr Swale Treatment Rainfall=2.65"Swale Treatment Printed 12/17/2009Prepared by Anderson Engineers, P.A.

Page 3HydroCAD� 9.00 s/n 02740 � 2009 HydroCAD Software Solutions LLC

Summary for Pond 1P: Treatment Swale

Treatment Facility:

The treatment facility will consist of a 12" deep dry swale system with typical side slopes of 6:1 and no greater than 3:1. Following the completion of all construction and basin stabilization measures are complete, excess soil and undesirable material must be carefully excavated and removed from the swale so that all accumulated silts, clays, organics, and other fine sediment material has been removed from the facility area. Once cleared of excess material, swale bottoms must be raked and loosened for optimal infiltration. Once properly prepared, bottom and sides must be stabilized with permanent vegetative cover via hydroseeding or sod. All construction methods and activities must comply with the approved procedures outlined in the NWFWMD ERP AH Volume II, Part V �Best Management Practices, Section 5.0.

Infiltration Rate:

Site is comprised of Reosta fine sand, 0 to 5 percent slopes with a Ksat Rating of 1476.9950 micrometers per second. Using FS=2, the infiltration rate =

17.5 in/hr. per USDA Natural Resources Conservation Service, Web Soil Survey

Inflow Area = 1.302 ac,66.49% Impervious, Inflow Depth = 0.89" for Swale Treatment event Inflow = 3.00 cfs @ 0.73 hrs, Volume= 0.096 af Outflow= 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 100%, Lag= 0.0 min Discarded= 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Stor-Ind method, Time Span= 0.00-12.00 hrs, dt= 0.05 hrs Peak Elev= 0.74' @ 1.60 hrs Surf.Area= 0.208 ac Storage= 0.096 af

Plug-Flow detention time= (not calculated: initial storage excedes outflow) Center-of-Mass det. time= (not calculated: no outflow)

Volume InvertAvail.StorageStorage Description #1 0.00' 0.156 af 3.00'W x 750.00'L x 1.00'H Swale w/ 6:1 Side Slopes Z=6.0

DeviceRouting InvertOutlet Devices #1Discarded 0.00' 17.500 in/hr Exfiltration over Surface area Conductivity to Groundwater Elevation = 0.00'

Discarded OutFlowMax=0.00 cfs @ 0.00 hrs HW=0.00' (Free Discharge) 1=Exfiltration( Controls 0.00 cfs)

FDOT 1-hr Swale Treatment Rainfall=2.65"Swale Treatment Printed 12/17/2009Prepared by Anderson Engineers, P.A.

Page 4HydroCAD� 9.00 s/n 02740 � 2009 HydroCAD Software Solutions LLC

Pond 1P: Treatment Swale

Inflow

Discarded

Hydrograph

Time (hours)

1211109876543210

F l o w c f s

Inflow Area=1.302 ac

Peak Elev=0.74'

Storage=0.096 af

3.00 cfs @ 0.73 hrs

DISCHARGE= 0.00 cfs @ 0.00 hrs

QUANTITY TREATMENT VIA EXFILTRATION

6'-0" 6'-0" 6'-0"

E.

G.

E.

G.

E.

G.

+2

.0

3:1

E.

G.

-1.

0'

3'-0"

21'-0"

ALL DISTURBED SURFACES TO

BE SODDED W/ BERMUDA UPON

COMPLETION (TYP)

PROPOSED 6" CONCRETE

MAAS STORAGE PAD (SEE A-1

FOR CONC. & REINF. DETAILS)

ALL COMPACTED FILL TO BE SODDED

W/ BERMUDA UPON COMPLETION (TYP)

SEE SHEET C-1 FOR

TREATMENT FACILITY

PREPARATION NOTES

E.

G.

-3

E.

G.

-1.

0'6:1 max 6:1 max

FLAT

FLAT

TOP OF DITCH CHECK ELEVATION

(SEE PLANS FOR LOCATIONS &

DETAIL C/C-2 FOR CROSS-SECTION)

6:1 (MIN. 3:1)

S W

A L E

C E N T E R L

IN

E

E.

G.

6.0' (TYP.)

E.G.

E.

G.

-12

TY

P)

ALL DISTURBED SURFACES TO

BE SODDED W/ BERMUDA UPON

COMPLETION (TYP)

6:1 (MIN. 3:1)

6.0' (TYP.)

W

TOP OF SWALE= E.G.

BOTTOM OF SWALE= E.G.-1.0'

6:1 (MIN. 3:1) 3:1

4'-6" 1'-0" 3'-0"

E.

G.

-3

ALL DISTURBED SURFACES TO

BE SODDED W/ BERMUDA UPON

COMPLETION (TYP)

SEE SHEET C-1 FOR TREATMENT

FACILITY PREPARATION NOTES

TYNDALL A.F.B., FL. 32403

325th CIVIL ENGINEERING SQUADRON

Task Order No.

SHEET:

PROJ. NO.

SCALE:

DATE:

Sheet Title

DRAWN BY:

DESIGNED BY:

TYNDALL A.F.B., FL. 32403

MTNT/MPI Job No.

C-4

CONSTRUCT MAAS

STORAGE PAD

CEMERT

0002STORMWATER & EROSION CONTROL

A. WHITTEMORE

A. KRINER

17 DEC 09

AS NOTED

09-1085

4 6

A APPROVED PER CE 18 FEB 10 AAK

B AS BUILTS 16 AUG 10 AAK

SWALE TREATMENT HYDRAULIC ANALYSIS SUMMARY

AutoCAD SHX Text Not Valid Without Signature and Raised Seal of Licensed Engineer

AutoCAD SHX Text

ANDERSON ENGINEERS, P.A.

AutoCAD SHX Text 78 Ricker Avenue

AutoCAD SHX Text Santa Rosa Beach, Florida

AutoCAD SHX Text

PHONE: (850) 231-4540

AutoCAD SHX Text

FAX: (850) 231-7980

AutoCAD SHX Text Certificate of Authorization: # 25932

AutoCAD SHX Text

NOT FOR CONSTRUCTION

AutoCAD SHX Text

OF

AutoCAD SHX Text

NO.

AutoCAD SHX Text M

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text O

AutoCAD SHX Text M

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text O

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text D

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

SHT. REF. NO.

AutoCAD SHX Text Terry L. Anderson, P.E. Florida Reg. No. 33553

AutoCAD SHX Text C-2

AutoCAD SHX Text A

AutoCAD SHX Text 1/2" = 1'-0"

AutoCAD SHX Text

TREATMENT SWALE TYPICAL CROSS SECTION

AutoCAD SHX Text C-2

AutoCAD SHX Text B

AutoCAD SHX Text 1/2" = 1'-0"

AutoCAD SHX Text

CONVEYANCE SWALE TYPICAL CROSS SECTION

AutoCAD SHX Text C-2

AutoCAD SHX Text C

AutoCAD SHX Text 1/2" = 1'-0"

AutoCAD SHX Text

DITCH CHECK TYPICAL CROSS SECTION

AutoCAD SHX Text

TRENCH

AutoCAD SHX Text

4" WIDE

AutoCAD SHX Text 8"

AutoCAD SHX Text 28"

AutoCAD SHX Text 36"

AutoCAD SHX Text

LAND SURFACE

AutoCAD SHX Text

POST (TYPICAL)

AutoCAD SHX Text 2"x4" WOODEN

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

LAND SURFACE

AutoCAD SHX Text

12" MINIMUM

AutoCAD SHX Text

(FDOT 985 SPEC)

AutoCAD SHX Text

FILTER FABRIC

AutoCAD SHX Text

4' MINIMUM

AutoCAD SHX Text

6' MAXIMUM

AutoCAD SHX Text C-2

AutoCAD SHX Text D

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

TYPICAL SILT FENCE ERECTION DETAIL

Sheets and Views
20100823 - AB1141 091085-ANDERSON SWALE 12-18-09-C-4

File details come from the government source that posted it. Updated .