T-502.pdf

PDF 395 KB Posted

Attached to
Movement of RAPCON System
Solicitation number
FA4819-1-9-Q-3010
Issued by

About this file

Comm Infrastructure Diagram 5

View the file

Other files

File Type Posted
T-102.pdf PDF
649_Floor_Plan.pdf PDF
T-001.pdf PDF
T-401.pdf PDF
T-601.pdf PDF
T-103.pdf PDF
Questions_and_Answers_v3.pdf PDF
T-101.pdf PDF
Questions_and_Answers_v1.pdf PDF
TYNDALL_AFB_FL-B216UPS-oneline.pdf PDF
Fiber_Install_route-2.pdf PDF
Fiber_Install_route-4.pdf PDF
Fiber_Install_route-3.pdf PDF
RAPCON_Power_Distribution_9_apr.pdf PDF
Fiber_Install_route-1.pdf PDF
RAPCON_Move_RFQ.pdf PDF
Cannopies_layout..pdf PDF
Fiber_Install_route-5.pdf PDF
Tyndall_RAPCON_Move_SOW_Final.pdf PDF
RAPCON_Equipment_Layout.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

K J Z

M V

C

J C

R A

I S

E D

F

L O

O R

G

O

U N

D I N

G

D

E T

A I L S

T-502

E A

F

SCALE:

T-502

TYPICAL COPPER STRAND CABLE

GROUND CONNECTION

NOT TO SCALE

SCALE:

T-502

TYPICAL RAISED FLOOR PEDESTAL

GROUND CONNECTION

NOT TO SCALE

SCALE:

T-502

TYPICAL INTERIOR COLUMN

GROUND CONNECTION

NOT TO SCALE

SCALE:

T-502

TYPICAL COPPER STRAND CABLE

TYPICAL SIGNAL REFERENCE GRID (SRG)

NOT TO SCALE

T-502

T-502

A B C D

A B C D

I S

O

S h e e t

F i l e

N a m e

S o l i c i t a t i o n

N u m b e r

E F G H

Number:

I

Reference

Sheet

R e v i e w e d

B y

C h e c k e d

B y

D e s i g n e d

B y

D r a w n

B y

D a t e

F i l o

E F G H I

A P

R I L

T d w g

U S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

M O

B I L

E

A

L A

B A

M A

P a r k w a y

L a n e

S u i t

N o r c r o s s

G

A

P h o n e

F a x

W e b w w w p o n d c o c o m

100% FINAL SUBMITTAL

F Y

A

I

C

N

T R

L

S

Q U

A D

R O

N

O P

E R

A T

I O

S

T

A

I N

I N

G

C

O M

P L

E X

T Y

N D

A L

L

A

I

F

R

E

B

A S

E

F

L O

R I D

A

P R

O J E

T

D R

A W

I N

G

R

E V

I S

I O

N S

R E

V

D E

S C

R I P

T I O

N A

P R

V D

D

A T

E P

R E

P

B

Y

TELECOMMUNICATIONS MAIN GROUNDING BUSBAR LOCATED IN ENTRANCE

FACIILITY 169. SEE 2/T-401 AND 5/T-502.

TELECOMMUNICATIONS GROUNDING BUSBAR LOCATED IN SERVER ROOM 134.

SEE 1/T-401 AND 5/T-502.

BUILDING STEEL LOCATED AS CLOSE AS POSSIBLE TO TMGB.

BUILDING STEEL LOCATED AS CLOSE AS POSSIBLE TO TGB.

PROVIDE "CAD WELD" CONNECTION AT BUILDING STEEL.

#6 COPPER BOND CONDUCTOR IN 3/4" EMT.

#350 COPPER BONDING CONDUCTOR IN 3/4" EMT.

#3/0 COPPER BONDING CONDUCTOR IN 3/4" EMT.

PROVIDE ADDITIONAL BONDING CONNECTIONS IN ROOM 169 FROM TMGB TO

CABLE RUNWAYS, EQUIPMENT RACKS, SURGE PROTECTORS, AND ENTRANCE

CONDUIT.

PROVIDE ADDITIONAL BONDING CONNECTIONS IN ROOM 134 FROM TGB TO

CABLE RUNWAYS, EQUIPMENT RACKS, AND PATHWAYS.

TELECOMMUNICATIONS GROUNDING BUSBAR LOCATED IN ROOM 116. SEE 1/T-101

AND 5/T-502.

PROVIDE A #6 AWG COPPER CABLE FROM CABINET GROUNDING CONNECTOR TO

TELECOMMUNICATIONS GROUNDING BUSBAR (TGB), WITH DOUBLE LUG CLAMP

FOR CONNECTION TO TGB.

SCALE:

T-502

TELECOMMUNICATIONS GROUNDING SYSTEM

NOT TO SCALE

TYPICAL TMGB DRILLED HOLE DIMENSIONS

COMPRESSION

CONNECTOR W/

VIEWING WINDOW

TYPICAL TGB DRILLED HOLE DIMENSIONS

" NOMINAL

INSULATOR

STAINLESS STEEL

STANDOFF BRACKET

ELECTRO-TIN PLATED

COPPER GROUND BAR

" TYP.

" TYP.

TYPE

TMGB

TMGB

TMGB

TMGB

TGB

TGB

TGB

TGB

12"

16"

20"

24"

12"

16"

20"

24"

WIDTH

4"

4"

4"

4"

2"

2"

2"

2"

THICKNESS

1/4"

1/4"

1/4"

1/4"

1/4"

1/4"

1/4"

1/4"

MINIMUM

LENGTH

MINIMUM NUMBER OF

PAIRS OF 5/16"

DIAMETER HOLES

MINIMUM NUMBER OF

PAIRS OF 7/16"

DIAMETER HOLES

TELCOMMUNICATIONS MAIN GROUND BAR (TMGB) &

TELECOMMUNICATIONS GROUND BAR (TGB) SCHEDULE

1"

1 2

SCALE:

T-502

TELECOMMUNICATIONS TGB & TMGB GROUND BAR DETAIL

NOT TO SCALE

(APPLIES TO 6/T-502 ONLY)

R E

C O

A

W I N

G

N

O

C

O R

R E

C T

I O

N S

M A

P

K

J Z

R D

THE RECORD DRAWING HAS BEEN PREPARED BY THE DESIGN

PROFESSIONAL BASED UPON INFORMATION FURNISHED BY

THE CONTRACTOR. THE DESIGN PROFESSIONAL CANNOT

ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR

THE ACCURACY OR THIS RECORD DRAWING OR ANY ERRORS

OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO IT AS

A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE

ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS

ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE.

File details come from the government source that posted it.