Diagram Legend
View the file
Other files
| File | Type | Posted |
|---|---|---|
| T-401.pdf | ||
| T-601.pdf | ||
| T-101.pdf | ||
| T-102.pdf | ||
| 649_Floor_Plan.pdf | ||
| T-502.pdf | ||
| T-103.pdf | ||
| Questions_and_Answers_v3.pdf | ||
| TYNDALL_AFB_FL-B216UPS-oneline.pdf | ||
| Questions_and_Answers_v1.pdf | ||
| Fiber_Install_route-2.pdf | ||
| Fiber_Install_route-4.pdf | ||
| Fiber_Install_route-3.pdf | ||
| RAPCON_Equipment_Layout.pdf | ||
| RAPCON_Power_Distribution_9_apr.pdf | ||
| Fiber_Install_route-1.pdf | ||
| RAPCON_Move_RFQ.pdf | ||
| Cannopies_layout..pdf | ||
| Fiber_Install_route-5.pdf | ||
| Tyndall_RAPCON_Move_SOW_Final.pdf |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K J Z
M A
P
J C
L E
G E
N D
A
B B
R E
V I A
T I O
N S
T E
L E
C O
M M
U N
I C
A T
I O
N S
T-001
E A
F
COMMUNICATIONS OUTLET, ONE VOICE AND ONE DATA JACK, MOUNTED
18" AFF UIO (NIPR), C=FLUSH CEING MOUNT, SEE DETAIL 2/T-503.
COMMUNICATIONS OUTLET, ONE VOICE JACK, MOUNT 60" AFF UIO.
SEE DETAIL 3/T-503.
FLOOR BOX FLUSH MOUNTED IN RAISED FLOOR, WITH TWO BARRIERED
COMPARTMENTS. ONE COMPARTMENT WITH ONE DUPLEX RECEPTACLE
CATV OUTLET, MOUNT 7'-6" AFF UIO
SEE DETAIL 4/T-503.
ABOVE CEILING CABLE TRAY.
BELOW RAISED FLOOR CABLE TRAY.
A B C D
A B C D
I S
O
S h e e t
F i l e a m e
S o l i c i t a t i o n
N u m b e r
E F G H
Number:
I
Reference
Sheet
R e v i e w e d
B y
C h e c k e d
B y
D e s i g n e d
B y
D r a w n y
D a t e
F i l o
E F G H I
A P
R I L
T d w g
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
M O
B I L
E
A
L A
B A
M A
P a r k w a y
L a n e
S u i t
N o r c r o s s
G
A
P h o n e
F a x
W e b w w w p o n d c o c o m
100% FINAL SUBMITTAL
F Y
A
I R
C
O N
T R
L
S
Q U
A D
R O
N
O P
E R
A T
I O
S
T
A
I N
I N
G
C
O M
P L
E X
T Y
N D
A L
L
A
I
F
R
E
S
E
F
L O
R I D
A
P R
O J E
T
D R
A W
I N
G
R
E V
I S
I O
N S
R E
V
D E
S C
R I P
T I O
N A
P R
V D
D
A T
E P
R E
P
B
Y
CEILING OR WALL MOUNTED JUNCTION BOX
RACEWAY CONCEALED IN WALLS AND/OR ABOVE CEILING
RACEWAY CONCEALED BELOW SLAB OR GRADE
RACEWAY EXPOSED
PULL OR JUNCTION BOX
GROUND CONNECTION
COMMUNICATIONS OUTLET AND RECESSED WEATHERPROOF TELEPHONE
ENCLOSURE MOUNTED 60" AFF UIO, WITH ONE RJ-45 VOICE JACK.
EMPTY 4" SQUARE BOX WITH SINGLE GANG PLASTER RING FOR FUTURE
GFGI USER LAN JACK, MOUNTED 18" AFF UIO, SEE DETAIL 6/T-503.
COMMUNICATIONS OUTLET, ONE VOICE AND THREE DATA JACKS, MOUNTED
18" AFF UIO (NIPR), SEE DETAIL 1/T-503.
COMMUNICATIONS OUTLET, ONE DATA JACK, MOUNTED 18" AFF UIO (NIPR),
C= FLUSH CEILING MOUNT. SEE DETAIL 3/T-503.
COMMUNICATIONS OUTLET, TWO MT-RJ MULTI-MODE DUPLEX FIBER OPTIC
ADAPTERS MOUNTED 18" AFF UIO (SIPR), SEE DETAIL 5/T-503.
AND ONE COMPARTMENT WITH TWO RJ-45 NIPR JACKS AND SPACE FOR
FLOOR BOX FLUSH MOUNTED IN CONCRETE FLOOR SLAB, WITH THREE
BARRIERED COMPARTMENTS, ONE COMPARTMENT WITH ONE DUPLEX
RECEPTACLE, ONE COMPARTMENT WITH TWO RJ-45 NIPR JACKS AND TWO
MT-RJ MULTI-MODE DUPLEX FIBER OPTIC SIPR ADAPTERS, AND ONE EMPTY.
COMPARTMENT FOR FUTURE GFGI LAN JACKS. SEE DETAIL 8/T-503.
FLOOR BOX FLUSH MOUNTED IN CONCRETE FLOOR SLAB, WITH THREE
BARRIERED COMPARTMENTS, ONE COMPARTMENT WITH ONE DUPLEX
RECEPTACLE, ONE COMPARTMENT WITH TWO RJ-45 NIPR JACKS, AND ONE
EMPTY COMPARTMENT FOR FUTURE GFGI LAN JACKS. SEE DETAIL 9/T-503.
FLOOR BOX FLUSH MOUNTED IN CONCRETE FLOOR SLAB, WITH TWO BARRIERED
COMPARTMENTS. ONE COMPARTMENT WITH ONE DUPLEX RECEPTACLE
AND ONE COMPARTMENT WITH TWO RJ-45 NIPR JACKS. SEE DETAIL 10/T-503.
FUTURE GFGI NETWORK CONNECTORS. SEE DETAIL 7/T-503.
FLOOR BOX FLUSH MOUNTED IN CONCRETE FLOOR SLAB, WITH TWO BARRIERED
COMPARTMENTS. ONE COMPARTMENT WITH ONE DUPLEX RECEPTACLE
AND ONE COMPARTMENT WITH TWO RJ-45 NIPR JACKS AND TWO MT-RJ
MULTI-MODE DUPLEX FIBER OPTIC SIPR ADAPTERS. SEE DETAIL 1/T-501.
FLOOR BOX FLUSH MOUNTED IN RAISED FLOOR, WITH TWO BARRIERED
COMPARTMENTS. ONE COMPARTMENT WITH ONE DUPLEX RECEPTACLE
AND ONE COMPARTMENT WITH ONE RJ-45 NIPR JACKS AND SPACE FOR
FUTURE GFGI NETWORK CONNECTORS. SEE DETAIL 11/T-503.
GENERAL NOTES (APPLY TO THIS SHEET ONLY):
1. ALL TELECOMMUNICATIONS SYSTEMS AND EQUIPMENT SHALL
MEET THE REQUIREMENTS OF UFC 3-580-01
TELECOMMUNICATION BUILDING CABLING SYSTEMS PLANNING
AND DESIGN, HQ AETC FIRST 400 FEET STANDARD GUIDANCE
AT ALL AETC BASES, AND ETL 02-12 COMMUNICATIONS AND
INFORMATION SYSTEMS CRITERIA FOR AIR FORCE FACILITIES.
2. CONTRACTOR SHALL PROVIDE RED/BLACK SEPARATION OF
POWER CABLES, UNCLASSIFIED (NIPRNET AND TELEPHONE)
CABLES AND CLASSIFIED COMMUNICATIONS CABLES IN
ACCORDANCE WITH AFSS1 7702.
R E
C O
A
W I N
G
N
O
C
O R
R E
C T
I O
N S
M A
P
K
J Z
R D
THE RECORD DRAWING HAS BEEN PREPARED BY THE DESIGN
PROFESSIONAL BASED UPON INFORMATION FURNISHED BY
THE CONTRACTOR. THE DESIGN PROFESSIONAL CANNOT
ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR
THE ACCURACY OR THIS RECORD DRAWING OR ANY ERRORS
OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO IT AS
A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE
ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS
ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE.
File details come from the government source that posted it.