T-401.pdf

PDF 162 KB Posted

Attached to
Movement of RAPCON System
Solicitation number
FA4819-1-9-Q-3010
Issued by

About this file

Comm Infrastructure Diagram 4

View the file

Other files

File Type Posted
T-601.pdf PDF
T-102.pdf PDF
649_Floor_Plan.pdf PDF
T-001.pdf PDF
T-502.pdf PDF
T-103.pdf PDF
Questions_and_Answers_v3.pdf PDF
T-101.pdf PDF
Questions_and_Answers_v1.pdf PDF
TYNDALL_AFB_FL-B216UPS-oneline.pdf PDF
Fiber_Install_route-2.pdf PDF
Fiber_Install_route-4.pdf PDF
Fiber_Install_route-3.pdf PDF
RAPCON_Power_Distribution_9_apr.pdf PDF
Fiber_Install_route-1.pdf PDF
RAPCON_Move_RFQ.pdf PDF
Cannopies_layout..pdf PDF
Fiber_Install_route-5.pdf PDF
Tyndall_RAPCON_Move_SOW_Final.pdf PDF
RAPCON_Equipment_Layout.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B

A

A

RACK 2 4

RACK 1 4

TMGB

RACK 3 4

11 11

B

LC-13 LC-14 LC-15

UA

TYPICAL OF 16

RACK 4

RACK 5

RACK 6

TGB

C

CD

D

9 10

UDP

UB

UPS-B

BYPASS-B

UPS-A

BYPASS-A

UB-1

UB-3

UB-5

CABLE TRAYS LOCATED BELOW RAISED

FLOOR NOT SHOWN FOR CLARITY.

K J Z

M V

C

J C

E N

L A

R G

E D

P

L A

N S

T E

L E

C O

M M

U N

I C

A T

I O

N S

T-401

E A

F

A B C D

A B C D

I S

O

S h e e t

F i l e

N a m e

S o l i c i t a t i o n

N u m b e r

E F G H

Number:

I

Reference

Sheet

R e v i e w e d

B y

C h e c k e d

B y

D e s i g n e d

B y

D r a w n y

D a t e

F i l o

E F G H I

A P

R I L

T d w g

U S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

M O

B I L

E

A

L A

B A

M A

P a r k w a y

L a n e

S u i t

N o r c r o s s

G

A

P h o n e

F a x

W e b w w w p o n d c o c o m

100% FINAL SUBMITTAL

F Y

A

I R

C

O N

T R

L

S

Q U

A D

R O

N

O P

E R

A T

I O

S

T

A

I N

I N

G

C

O M

P L

E X

T Y

N D

A L

L

A

I

F

R

E

A S

E

F

L O

R I D

A

P R

O J E

T

D R

A W

I N

G

R

E V

I S

I O

N S

R E

V

D E

S C

R I P

T I O

N A

P R

V D

D

A T

E P

R E

P

B

Y

PROVIDE 8' HIGH FIRE RATED PLYWOOD BACKBOARD ON WALLS INDICATED,

BOTTOM OF PLYWOOD 6" AFF. PAINT BACKBOARD WITH TWO COATS OF LIGHT

GRAY FIRE RETARDANT PAINT, ON ALL SIDES INCLUDING EDGES. DO NOT PAINT

OVER PLYWOOD RATING STAMP.

TWO STACKED WIRE BASKET CABLE TRAYS. LOWER TRAY SHALL BE FOR NIPRNET

AND SHALL BE 2" x 16". UPPER TRAY SHALL BE FOR FUTURE USER CABLES AND

SHALL BE 2" x 6". PROVIDE 6" CLEARANCE BETWEEN TRAYS. COORDINATE EXACT

ELEVATION OF TRAYS WITH GOVERNMENT. SUPPORT TRAY IN ACCORDANCE WITH

MANUFACTURER'S RECOMMENDATIONS.

4" CONDUIT SLEEVE THROUGH WALL.

BOLT RACKS TO FLOOR.

LABEL ALL RACKS, CONDUITS, BACKBOARDS, CABLES AND PATCH PANELS IN

ACCORDANCE WITH ANSI TIA/EIA 606A.

TWO 2" X 6" WIRE BASKET CABLE TRAYS LOCATED ABOVE ACCESSIBLE CEILING.

GFGI EQUIPMENT CABINETS.

UPS.

GFGI INTRUSION DETECTION SYSTEM (IDS) CONTROLLER IN GFCI ENCLOSURE.

GFGI CARD ACCESS SYSTEM (CAS) CONTROLLER IN GFCI ENCLOSURE.

TERMINATE CONDUIT TIGHT AGAINST WALL, TOP 4" AFF. PROVIDE PLASTIC

BUSHING ON CONDUIT.

EMPTY 2" CONDUIT WITH PULL STRING TO EXISTING CATV PEDESTAL ON BEACON

BEACH ROAD.

FOUR, 4" CONDUITS TO EXISTING MANHOLE 334. PROVIDE TWO CONDUITS EACH

WITH FOUR 1 1/4" FABRIC INNERDUCTS.

NEMA 5-30R FOR EACH RACK.

2" X 8" WIRE BASKET CABLE TRAY LOCATED ABOVE ACCESSIBLE CEILING.

2" X 6" WIRE BASKET CABLE TRAY LOCATED ABOVE ACCESSIBLE CEILING.

THREE 2" X 6" WIRE BASKET CABLE TRAYS LOCATED ABOVE ACCESSIBLE CEILING.

THREE STACKED WIRE BASKET CABLE TRAYS. LOWER TRAY SHALL BE NIRPNET

AND SHALL BE 2" x 12". MIDDLE TRAY SHALL BE FUTURE USER CABLES AND SHALL

BE 2" x 6". TOP TRAY SHALL BE FOR SIPRNET AND SHALL BE 2" x 6". PROVIDE 6"

CLEARANCE BETWEEN TRAYS. COORDINATE EXACT ELEVATION OF TRAYS WITH

GOVERNMENT. SUPPORT TRAYS IN ACCORDANCE WITH MANUFACTURER'S

RECOMMENDATIONS.

2" x 6" NIPR CABLE TRAY BELOW RAISED FLOOR.

2" x 6" USER LOCAL LAN CABLE TRAY BELOW RAISED FLOOR.

PROVIDE VERTICAL LADDER RACK TO ROUTE CABLES FROM 4" CONDUIT SLEEVES

THROUGH WALL, TO WIRE BASKET CABLE TRAYS.

THREE 4" CONDUITS, BELOW SLAB, FROM ROOM 169 TO ROOM 134.

TWO 4" CONDUITS, BELOW SLAB, FROM ROOM 134 TO ROOM 116.

KEY NOTES:

T-401

ENLARGED SERVER ROOM 134

T-401

ENLARGED COMM ROOM 169

SCALE: 1/2" = 1'-0"

SCALE: 1/2" = 1'-0"

2 0 2 4

SCALE: 1/2" = 1'-0"

R E

C O

A

W I N

G

N

O

C

O R

R E

C T

I O

N S

M A

P

K

J Z

R D

THE RECORD DRAWING HAS BEEN PREPARED BY THE DESIGN

PROFESSIONAL BASED UPON INFORMATION FURNISHED BY

THE CONTRACTOR. THE DESIGN PROFESSIONAL CANNOT

ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR

THE ACCURACY OR THIS RECORD DRAWING OR ANY ERRORS

OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO IT AS

A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE

ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS

ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE.

File details come from the government source that posted it.