Attachment 6_Technical Reference Materials.pdf
PDF 47 MB Posted
- Attached to
- PKA-Giant Voice Equipment -6 CS (Amendment 6)
- Solicitation number
- FA481426Q0072
About this file
Summary
This attachment contains technical reference materials for the MacDill Air Force Base Mass Notification System (Project No. NVZR 16-0065), serving as supporting documentation for the PKA-Giant Voice Equipment solicitation. The materials include detailed product specifications, installation instructions, and interface requirements for the integrated emergency response notification system.
The attachment provides comprehensive technical specifications for key system components: Corning FREEDM LST 12-strand single-mode fiber optic cable (Part No. 012ESF-T4101D20) with riser rating and gel-free waterblocking technology; Corning buffer tube fan-out kits (Part No. FAN-BT25-12) for field termination of loose tube cables; Panduit LC OptiCam pre-polished fiber optic connectors with zirconia ceramic ferrules and factory-terminated fiber stubs eliminating field polishing; and wall-mount fiber LIU panels. The documentation includes installation instructions for Walter Kidde ANS25MD2/ANS50MD2/ANS100MD*2 voice evacuation interface systems (25W, 50W, and 100W models respectively), which function as self-contained amplifiers with tone generators, digital message repeaters, and supervisory interfaces compatible with UL-listed Fire Alarm Control Panels. Critical specifications detail electrical ratings (120 VAC @ 60 Hz input), battery requirements (24V 7AH to 24AH), speaker output options (25/70 Vrms selectable), frequency response (400-4000 Hz), output protection, and wiring configurations for Class A and Class B installations. The interface specification document (Rev A, April 10, 2017) defines the operational interface between Edwards Hyperspike high-powered speaker array (Edwards HPSA) and Monaco BT-X WAC Wide-Area Mass Notification Communicator, specifying status monitoring via eight auxiliary relay contacts, live voice activation protocols, pre-recorded message triggering through relay boards, system integration requirements including NEMA1 enclosure provisions, 24VDC power sourcing with battery backup, and D-21 system capability upgrades. Additional documentation includes engineering drawings for pole-mount brackets and electronics control cabinet (UTC MN-HSECCPM1Z) with detailed bill of materials and assembly specifications.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 4
1. Fiber & Conductors
2. Giant Voice Equipment Cut Sheet
3. MNS Control Centers
4. RPR SUS Base Emergency Response Notification Syst As-Builts
5. E-603 RPR SUS Base Emergency Response Notification Syst As-Builts
Manufacturer / Part Number Item Description
Corning / 012ESF-T4101D20 12 Strand SM Loose Tube
Corning / FAN-BT25-12 Corning Fan Out Kit SM
Panduit / FLCSSCBUY LC Panduit SM Fiber Optic Connector
Panduit / FWME2 Wall Mount Fiber LIU
Panduit / FAP12WBULCZ 12 Port SM LC Fiber Adapter Panel
Comtran / 38600 Category 6 Plenum Cabling Blue
Hubbell / ISB2W Surface Mount Box 2-Port White
Hubbell / HXJ6W Category 6 Jack White
Submittal Table of Contents
MacDill AFB - Mass Notification
Part Number: 012ESF-T4101D20
Cross Section of Part Number: 012ESF-T4101D20
FR / UV-Resistant Outer Jacket
Ripcord
Fiber
Buffer Tube
Dielectric Strength Members
Corning FREEDM® LST™ gel -free cables are flame -retardant, indoor/outdoor, riser -rated cables designed for interbuilding and intrabuilding backbones in aerial, duct and riser applications. With a riser rating, there is no need for a transition splice when entering the build-ing. Available in a compact design, these cables are protected against water penetration by innovative wa-terblocking tapes and yarns that swell to absorb water.
Waterblocking without the use of messy gels provides more efficient and craft -friendly cable preparation, allows easier cable access and simplifies the use of buffer tube fan -out kits. The buffer tubes and fibers in each tube are color coded for quick, easy identification.
Note: This cable is available in 12 different jacket colors
– blue, orange, green, brown, slate, white, red, black, yel-low, violet, rose and aqua. The colored jacket allows for easy visual identification of the cables while still providing all of the required environmental protection of an indoor/ outdoor cable jacket. Black is the standard jacket color using the part numbers shown here. Contact Customer Care at 1 -800 -743 -2675 to order other color options.
Features and Benefits Riser rating No transition splices when entering buildings
Gel-free waterblocking technology Craft-friendly cable preparation
Color-coded fibers Quick and easy identification
All-dielectric construction Requires no grounding or bonding
UV-resistant, flame-retardant jacket Rugged, durable and easy to strip
Standards Approvals and Listings National Electrical Code®
(NEC®) OFNR, CSA OFN
FT-4
Common Installations Outdoor lashed aerial and duct; indoor vertical riser and general purpose hori-zontal according to National Electrical Code (NEC) Article 770
FREEDM® LST™ Loose-Tube, Gel-Free Cable, Riser 12 F, Single-mode (OS2)
Product Specification 012ESF-T4101D20_NAFTA_AEN Page 1 | Revision date 2015-06-18 jhenderson
Rectangle
Standards Design and Test Criteria ANSI/ICEA S-104-696
Specifications
General Specifications Environment Indoor/Outdoor Cables
Application Aerial, Direct Buried, Duct, General Purpose Horizontal, (Vertical Riser)
Cable Type Loose Tube
Product Type Dielectric
Flame Rating Riser (OFNR)
Fiber Category Single-mode (OS2)
Temperature Range Storage -40 °C to 70 °C (-40 °F to 158 °F)
Installation -10 °C to 60 °C (14 °F to 140 °F)
Operation -40 °C to 70 °C (-40 °F to 158 °F)
Cable Design Fiber Count 12
Fiber Coloring Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua
Fibers per Tube 12
Number of Tube Positions 1
Number of Active Tubes 1
Tensile Strength Elements and/or Armoring - Layer 1 Dielectric strength members
Tensile Strength Elements and/or Armoring - Layer 2 Water-swellable dielectric strength members
Number of Ripcords 1
Outer Jacket Material Flame-Retardant, UV-Resistant
Outer Jacket Color Black
Page 2 | Revision date 2015-06-18
Mechanical Characteristics Cable Weight 56 kg/km (38 lb/1000 ft)
Nominal Outer Diameter 7.4 mm (0.29 in)
Max. Tensile Strength, Short-Term 1350 N (300 lbf)
Max. Tensile Strength, Long-Term 400 N (90 lbf)
Min. Bend Radius Installation 111 mm (4.4 in)
Min. Bend Radius Operation 37 mm (1.5 in)
Chemical Characteristics
RoHS Free of hazardous substances according to RoHS 2002/95/
EG
Fiber Specifications
Optical Characteristics (cabled) Fiber Name Single-mode (OS2)
Fiber Category G.652.D
Fiber Code E
Performance Option Code 01
Wavelengths 1310 nm / 1383 nm / 1550 nm
Maximum Attenuation 0.4 dB/km / 0.4 dB/km / 0.3 dB/km
Ordering Information Part Number 012ESF-T4101D20
Product Description FREEDM® LST™ Single-Tube, Gel-Free Cable, 12 F, Single-mode (OS2)
EAN Code 4042673236894
Page 3 | Revision date 2015-06-18
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA 800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcomm A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks.
All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified.
© 2015 Corning Optical Communications. All rights reserved.
Buffer Tube Fan-Out Kits A LANscape® Solutions Product
Applications
• Field termination of loose tube cables at indoor or outdoor cross-connects
Description Corning Cable Systems Indoor and Outdoor Buffer Tube Fan-Out Kits are specifically designed for the termination of 6- and 12-fiber buffer tubes. These buffer tube fan-out kits provide the ultimate solution for those users who want to field-install connectors. The kits provide the most compact, easy-to-install fan-out solution requiring no additional hard-ware or space than that required for terminating tight-buffered cables.
Indoor and outdoor kits feature a 900 µm fan-out assembly that is color-coded to match the fiber color scheme. The fan-out assembly is available with 6- or 12-fiber units in lengths of 25 or 47 inches. These different lengths provide the installer the flexibility needed for a variety of hardware options.
Features / Benefits
• Eliminates strain on fibers by isolating them from tensile forces
• Colored fan-out tubing
• Snap-together furcation unit eliminates epoxy for indoor kits
• Compact design
• Quick and easy to install
• Optimized for field termination of cables
• Excellent fiber routing capabilities
• Bend radius protection designed into each unit
• Outdoor kits include additional elements that compensate for wider temperature fluctuations common in outdoor environments
Buffer Tube Fan-Out Kit | Photo LAN365
Corning Cable Systems
Product Specifications
Buffer Tube Fan-Out Kit | Photo LAN49
• Indoor temperature range 0˚ to +70˚C Outdoor temperature range -40˚ to +70˚C
Buffer Tube Fan-Out Kits A LANscape® Solutions Product
To order a buffer tube fan-out kit, first determine the length of tubing required for connector termination, either 25 or 47 inches. Next, determine the number of fibers to furcate.
Length of Number of Fibers Part Number Tubing per Buffer Tube1
Indoor Buffer Tube Fan-Out Kits FAN-BT25-06 25 inches 6 FAN-BT47-06 47 inches 6 FAN-BT25-12 25 inches 12 FAN-BT47-12 47 inches 12
Outdoor Buffer Tube Fan-Out Kits FAN-OD25-06 25 inches 6 FAN-OD47-06 47 inches 6 FAN-OD25-12 25 inches 12 FAN-OD47-12 47 inches 12 Notes 1Refer to cable specifications.
Tool Kit and Tool Kit Consumables Part Number Description TKT-FANBT-A Buffer Tube Fan-Out Assembly Tool Kit includes buffer tube fan-out assembly fixture and buffer tube fan-out kit instructions TKT-FANBT-C Buffer Tube Fan-Out Assembly Consumables Kit includes buffer tube fan-out procedure instructions, buffer tube fan-out clamp, MSDS 411 adhesive, Loctite 411 adhesive, Kimwipes, alcohol wipes, and MSDS alcohol wipes
Corning Cable Systems
Corning Cable Systems LLC • PO Box 489 • Hickory, NC 28603-0489 USA 1-800-743-2675 • FAX: +1-828-901-5973 • International: +1-828-901-5000 • http://www.corning.com/cablesystems Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. Discovering Beyond Imagination is a trade-mark of Corning Incorporated. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified.
© 2000, 2005 Corning Cable Systems. All rights reserved. Published in the USA. LAN-103-EN / June 2005 / pdf
Bottom
Fan-Out AssemblyFurcation Unit
Top
44.5 mm (1.75 in)
7.7 mm (0.303 in)
11.3 mm (0.446 in) 20.1 mm
(0.791 in)
Kit Components | Drawing CPC-220/2/1 Completed Kit Dimensions | Drawing CPC-220/2/2 www.panduit .com
LC OptiCam® Pre-Polished Fiber Optic Connectors S P E C I F I C A T I O N S H E E T
LC OptiCam® Pre-Polished Connectors with Zirconia Ceramic Ferrules 10Gig™ 50/125μm (laser optimized) simplex: FLCSMCXAQY▲ 10Gig™ 50/125μm (laser optimized)
| duplex: | FLCDMCXAQY |
| 50/125μm simplex: | FLCSMC5BLY▲ |
| 50/125μm duplex: | FLCDMC5BLY |
| 62.5/125μm simplex: | FLCSMC6BLY▲ |
| 62.5/125μm duplex: | FLCDMC6BLY |
| 9/125μm simplex: | FLCSSCBUY▲ |
9/125μm duplex: FLCDSCBUY OptiCam® 1.6/2.0mm Boots 10Gig™multimode
| (aqua): | FMCBT2AQ-X* |
| Multimode (black): | FMCBT2BL-X |
| Singlemode (blue): | FSCBT2BU-X |
OptiCam® 3.0mm Boots 10Gig™multimode
| (aqua): | FMCBT3AQ-X* |
| Multimode (black): | FMCBT3BL-X |
| Singlemode (blue): | FSCBT3BU-X |
*X = Bag of 10 Boots; 100 per carton.
OptiCam® Termination Tooling OptiCam® Termination Kit: FCAMKIT OptiCam® Conversion Kit (upgrades Opti-Crimp® Kit to also terminate OptiCam® Connectors): FPPKIT-CVY Field Polish Kit Upgrade (upgrades Field Polish Kit to also terminate
| OptiCam® Connectors): | FIELDKITUPG |
| LC cradles (2 per pkg.): | FLCC |
LC Fiber Optic Adapters
| 10Gig™multimode: | FADJLCAQ-L* |
| Multimode: | FADJLCEI-L |
| Singlemode: | FADJLCZBU-L |
*L = Bag of 50 adapters; 100 per carton.
Mini-Com® LC Adapter Modules
| 10Gig™multimode: | CMDJAQLC** |
| Multimode: | CMDJEILC** |
| Singlemode: | CMDJLCZBU |
**Substitute for module color: EI = Electric Ivory, BU = Blue, BL = Black, IW = Off White, AW = Arctic White Opticom® LC Fiber Adapter Panels 6 duplex MM adapters: FAP6WEIDLC 6 duplex SM adapters: FAP6WBUDLCZ 12 duplex MM adapters: FAP12WEIDLC 12 simplex SM adapters: FAP12WBULCZ Opti-Core ® LC Patch Cords
| Duplex LC to LC: | F^E10-10M‡Y |
| Simplex LC to LC: | F^F10-10M‡Y |
| Duplex SC to LC: | F^E3-10M‡Y |
| Simplex SC to LC: | F^F3-10M‡Y |
LC Lock-in Duplex Clip LC lock-in duplex clip: FLCCLIW-X ▲Add -C to simplex connector part numbers for bulk packs of 100 connectors.
^Substitute for fiber type: 6 = 62.5/125μm OM1, 5 = 50/125μm OM2, X = 10Gig™ 50/125μm OM3/OM4 or 9 = 9/125μm OS1/OS2.
‡Substitute for length in meters: 1, 2, 3, 5 or 10.Contact Customer Service for other available lengths.
a p p l i c a t i o n s LC fiber optic connectors are widely used in fiber optic backbone and horizontal applications for high-speed data transmission. Typical applications for LC OptiCam® Connectors include maintenance or emergency restoration of fiber networks and retrofit/initial install in both behind-the-wall (BTW) and in the permanent side of panelized interconnect and cross-connect. LC OptiCam®
Connectors eliminate the need for end face polishing and adhesive providing easier, faster installation, especially in remote areas and confined spaces.
The hand-held OptiCam® Termination Tool gives installers the flexibility to terminate in very close proximity to the application without having to switch tools or find benchtop space.
t e c h n i c a l i n f o r m a t i o n Standards requirements: TIA/EIA-604 FOCIS-10 compatible; exceeds
TIA/EIA-568-B.3 requirements
Fiber compatibility: 62.5/125μm OM1, 50/125μm OM2, 10Gig™ 50/125μm laser optimized OM3/OM4 and 9/125μm OS1/OS2
Fiber cable type: 900μm tight-buffered cable only
Fiber cable size: 1.6mm – 2.0mm and 3.0mm jacketed cable with optional boots
Ferrule type: Zirconia ceramic with a pre-polished fiber stub
Insertion loss: Ceramic: 0.3dB average (multimode and singlemode)
Return loss: Ceramic: >20dB (multimode), >26dB (10Gig™ multimode), >50dB (singlemode) s p e c i f i c a t i o n s LC small form factor (SFF) pre-polished connectors with rear pivot latch shall be TIA/EIA-604 FOCIS-10 compatible and contain a factory-terminated fiber, eliminating field polishing and adhesive. LC pre-polished connectors shall have an average insertion loss of 0.3dB per mated pair for multimode and singlemode fiber. LC pre-polished connectors shall captivate fiber and buffer in one action allowing for up to two re-terminations with no degradation in performance.
k e y f e a t u r e s a n d b e n e f i t s LC OptiCam ® Connectors
Factory pre-polished fiber stub endface
Eliminates inconsistent and time-consuming field polishing to deliver required optical performance; reduces termination time (less than half the time of field polish connectors) and the number of installation tools required
Dual cam design with fiber and buffer clamps
Secures both the fiber and the buffer during the camming step to facilitate consistent termination results; reduces the termination time compared to conventional termination methods Allows up to two re-terminations to achieve optimum termination results; reduces the number of rejected connectors and terminations to provide yield rates approaching 100% for lower installed costs
Translucent housing assembly
Facilitates inspection of the fiber termination quality; results in rapid installations, improved termination yields, and lower installed costs
Non-optical disconnect Maintains data transmission under tensile loads for jacketed cable
Mechanical cable retention Consistently provides higher than industry standard cable retention;
requires no adhesive, speeding installation
Zirconia ceramic ferrules Provide the highest durability for repeated matings
OptiCam® Termination Tool Universal termination tool Secures both fiber and buffer in one action for all OptiCam® Connectors with connector specific cradles (included); ensures fast, consistent, and optimal terminations
Integrated visual termination indicator (VTI)
Provide the highest durability for repeated matings
2.23 [56.6]
.25 [6.35]
[56.6]
(56.6) 2.23
(56.6)
.25 (6.35)
©2015 Panduit Corp.
ALL RIGHTS RESERVED.
FBSP19--WW-ENG
3/2015
LC OptiCam® Pre-Polished Fiber Optic Connectors
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADA
Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK cs-emea@panduit.com Phone: 44.20.8601.7200
PANDUIT JAPAN
Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020
PANDUIT LATIN AMERICA
Guadalajara, Mexico cs-la@panduit.com Phone: 52.33.3777.6000
Contact Customer Service by email: cs@panduit.com or by phone: 800.777.3300
Visit us at www.panduit.com For more information
Dimensions are in inches [Dimensions in brackets are in millimeters].
p e r f o r m a n c e i n f o r m a t i o n
Simplex Connector
Duplex Connector OptiCam® Termination Tool LC Lock-In Duplex Clip
Test Parameter Description Result
Qualification test suite (TIA/EIA-568-B.3 requirements)
Complete testing protocol per TIA/EIA-568-B.3 using TIA/EIA FOTPs that include mechanical, environ-mental and optical test sequences
Exceeds TIA/EIA-568-B.3 requirements
Connector intermatability Dimensional and material compliance to TIA/EIA standards
All connectors are FOCIS compatible with
TIA/EIA-604-10
Repeated mating 500 mate/unmate cycles Max. insertion loss: 0.75dB Min. return loss: 20dB
Exceeds TIA/EIA-568-B.3 test requirements:
<0.1dB additional insertion loss
Cable retention (straight pull):
900μm tight-buffered fiber
Jacketed cable
TIA/EIA-568-B.3 requirement:
0.5 lbs. load applied with <0.5dB increase in insertion loss after test
11.24 lbs. load applied with <0.5dB increase in insertion loss after test
Exceeds TIA/EIA-568-B.3 requirements:
1.0 lbs. avg. load applied with <0.2dB increase in insertion loss after test
11.24 lbs. load applied with <0.1dB increase in insertion loss after test*
*All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-FOTP-171.
s e l e c t i o n i n f o r m a t i o n Part Number Connector
Type Ferrule Material
Fiber Ferrule Finish
Backbone Color
Boot
Average Insertion Loss**
Return Loss
FLCSMCXAQY Simplex Zirconia Ceramic
10 GbE 50/125μm (laser optimized)
OM3/OM4
SPC Aqua Aqua 0.3dB >26dB
FLCDMCXAQY Duplex
FLCSMC5BLY Simplex Zirconia Ceramic 50/125μm OM2 SPC Black Black 0.3dB >20dB
FLCDMC5BLY Duplex
FLCSMC6BLY Simplex Zirconia Ceramic 62.5/125μm OM1 SPC Electric
Ivory Black 0.3dB >20dB
FLCDMC6BLY Duplex
FLCSSCBUY Simplex Zirconia Ceramic 9/125μm OS1/OS2 UPC Blue Blue 0.3dB >50dB
FLCDSCBUY Duplex
FLCSMC***Y FLCDMC***Y OCTT
(Patch cords available separately or in termination kits)
FLCCLIW-X
Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
PHYSICAL INFRASTRUCTURE SYSTEMS
A.
System
Overview
B.
Copper
Systems
C.
Fiber Optic
Systems
D.
Power over Ethernet
E.
Zone
Cabling
F.
Wireless
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure Management
J.
Overhead & Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets, Racks &
Cable
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Accessories
Q.
Index
Opticom® Wall Mount Enclosures
• Holds Opticom ® Fiber Adapter Panels (FAPs)
• Rugged all metal construction for fiber protection and secure mounting
• Compact design allows installation in tight areas
• Separate doors for service side and user side with optional keyed locks for added security
• Include fiber optic cable routing kit (grommets, cable ties, spools, strain relief bracket and ID/caution labels) for various cable management solutions
FWME2
FWME4
FWME8
All product color is black.
*MTP is a registered trademark of US Conec Ltd.
Part Number Part Description
Std.
Pkg.
Qty.
Fiber Wall Mount Enclosures
FWME2 Holds up to two QuickNet™ Cassettes, FAP, or FMP panels.
Dimensions: 12.00"W x 10.18"H x 2.32"D (304.8mm x 258.6mm x 59.1mm)
FWME4 Holds up to four QuickNet™ Cassettes, FAP, or FMP panels.
Dimensions: 16.11"W x 12.25"H x 3.52"D (409.2mm x 311.0mm x 89.4mm)
FWME8 Holds up to eight QuickNet™ Cassettes, FAP, or FMP panels.
Dimensions: 16.11"W x 16.11"H x 5.00"D (409.2mm x 409.2mm x 127.0mm)
Fiber Accessories
FELS Fiber enclosure lock for service side. 1
FELU Fiber enclosure lock for user side. 1
LC Fiber Optic Adapters k e y f e a t u r e s a n d b e n e f i t s a p p l i c a t i o n s t e c h n i c a l i n f o r m a t i o n s p e c i f i c a t i o n s LC small form factor (SFF) fiber optic adapters with integrated panel retention clips are TIA/EIA-604 FOCIS-10 compatible. Each LC simplex adapter shall connect one LC connector pair in one module space.
Each LC duplex adapter shall connect two LC connector pairs in one module space. LC adapters and adapter modules shall include phosphor bronze split sleeves for multimode applications or zirconia ceramic split sleeves for singlemode applications.
Standards requirements: TIA/EIA-604 FOCIS-10 compatible; exceeds TIA/EIA-568-B.3 requirements
Split sleeve material: Phosphor bronze or zirconia ceramic (required for singlemode applications)
Insertion loss: .1dB average (multimode and singlemode); supports the performance of FOCIS-10 compliant connectors/patch cords
Return loss: Supports singlemode (>40dB for SPC and >55dB for UPC) and multimode (>20dB) connector polish performance
Panduit LC SFF Fiber Optic Adapters can be used with Mini-Com® Modules, Patch Panels, Faceplates and Surface Mount Boxes for a complete LC system solution. LC adapters provide a rugged solution for LANs, public networks, storage area networks and fiber-to-the-desk applications. The high-density design and 1.25mm ferrules double the port density (compared to SC connectors) to reduce space requirements on racks, enclosures, panels and faceplates. LC adapters can also be mounted in high-density applications within Opticom® QuickNet™ Pre-Terminated MTP* Cassettes and Fiber Enclosures, and Opticom®
Fiber Adapter Panels (FAPs) and Enclosures.
HDCRT Connector Removal Tool can be used to simplify removal of connectors in high-density applications.
Integrated panel No metal clips to become bent, damaged or lost; simplex adapter retention clips clips automatically adjust for FOCIS-10 compliant panel thickness variations for improved mounting
Superior weld strength Provides a more durable product under stress for improved reliability and increased life
LC duplex adapters fit Doubles the density in the same rack space; substitute simplex SCs SC simplex adapter openings with duplex LCs to increase connectivity 100%
Short flange design Improved modularity and higher density usage
Choice of phosphor bronze or Provides an adapter split sleeve material option to fit specific zirconia ceramic split sleeves network requirements
Adapters available in System flexibility; modules are interchangeable within Panduit ®
Mini-Com ® Modules Mini-Com® Outlets, Boxes and Patch Panels
Adapters available in patch Provides a complete LC system solution panels, fiber adapter panels (FAPs) and Opticom ® QuickNet ™
Pre-Terminated MTP* Cassettes
Modules available in Allows color-coding for network segregation multiple colors
*MTP is a registered trademark of US Conec Ltd.
LC Sr./Jr. Fiber Optic Adapters
Duplex MM: FADJLCEI-L Duplex 10Gig™: FADJLCAQ-L Simplex 10Gig™ (zirc.): FASJLCZAQ-L Duplex 10Gig™ (zirc.): FADJLCZAQ-L Simplex SM (zirc.): FASJLCZBU-L Duplex SM (zirc.): FADJLCZBU-L L = Bag of 50 adapters; 100 per carton.
Mini-Com ® LC Sr./Sr. Adapter Modules Duplex MM: CMDSLC** Duplex 10Gig™: CMDSAQLCBL Duplex 10Gig™ (zirc.): CMDSAQLCZBL Duplex SM (zirc.): CMDSLCZ**
Mini-Com ® LC Sr./Jr. Adapter Modules Duplex MM: CMDJLC** Duplex 10Gig™: CMDJAQLCBL Duplex 10Gig™ (zirc.): CMDJAQLCZBL Duplex SM (zirc.): CMDJLCZ**
Opticom® LC Fiber Adapter Panels 6 duplex MM: FAP6WEIDLC 6 duplex 10Gig™ (zirc.): FAP6WAQDLCZ 6 duplex SM (zirc.): FAP6WBUDLCZ 12 duplex MM: FAP12WEIDLC 12 simplex SM (zirc.): FAP12WBULCZ
Opticom® QuickNet™ Pre-Terminated MTP* Cassettes 6 LC to MTP* (12f): FC^-12-10 12 LC to 2 MTP* (24f): FC^-24-10
LC Simplex Fiber Optic Connectors Multimode: FLCSMEI Singlemode: FLCSSBU
LC Duplex Fiber Optic Connectors Multimode (1.6 – 2mm): FLCDMEI Singlemode (1.6 – 2mm): FLCDSBU Multimode (900µm): FLCDM900EI Singlemode (900µm): FLCDS900BU
Opti-Core ® Fiber Optic Patch Cords Duplex LC to LC: F^E10-10M‡ Simplex LC to LC: F^F10-10M‡ Simplex LC to pigtail: F^B10-NM‡
HD Connector Removal Tool For LC and SC HDCRT
**Substitute for module color:
EI = Electric Ivory BU = Blue IG = International Gray WH = White TG = Technical Gray BL = Black AW = Arctic White IW = Off White EW = European White
^Substitute for fiber type:
X (OM3/OM4 – 10Gig™ 50/125µm), 5 (OM2 – 50/125µm), 6 (OM1 – 62.5/125µm) or 9 (OS1 – 9/125µm).
‡Substitute for length in meters: 1, 2, 3, 5 or 10 for patch cords, and 1, 2 or 3 for pigtails; singlemode patch cords are also available in 12, 15, 25 or 30 meter lengths. Contact Customer Service for other available lengths.
LC Sr./Sr. Fiber Optic Adapters
Duplex MM: FADSLCEI-L Duplex 10Gig™: FADSLCAQ-L Simplex 10Gig™ (zirc.): FASSLCZAQ-L Duplex 10Gig™ (zirc.): FADSLCZAQ-L Simplex SM (zirc.): FASSLCZBU-L Duplex SM (zirc.): FADSLCZBU-L L = Bag of 50 adapters; 100 per carton.
Panduit LC Connector/Adapter connection• www.panduit .com
SPECIFICATION SHEET
LC Fiber Optic Adapters
©2009 Panduit Corp.
ALL RIGHTS RESERVED.
WW-FBSP14
9/2009
Dimensions are in inches [Dimensions in brackets are in millimeters].
For a copy of PANDUIT product warranties, log on to www.panduit.com/warranty
Contact Customer Service by email: cs@panduit.com or by phone: 800-777-3300 and reference FBSP14
Visit us at www.panduit.com For more information d e s i g n i n f o r m a t i o n LC Adapter Type Description Application Type
Sr./Sr.
(Senior/Senior)
Has a FOCIS-10 senior adapter interface (without keyway) at each end.
Both ends accept FOCIS-10 compatible senior LC connectors (non-keyed; spring loaded ferrules).
Typically used for patch panel and outlet applications, including behind the wall applications.
Sr./Jr.
(Senior/Junior)
Has a FOCIS-10 senior adapter interface (without keyway) at one end and a FOCIS-10 compatible junior adapter interface (with keyway) at the other end.
Both ends accept all FOCIS-10 compatible senior LC connectors (non-keyed; spring loaded ferrules).
Junior end also accepts FOCIS-10 compatible junior LC connectors (keyed; fixed ferrule/springless).
Shorter profile of junior end accommodates tighter applications behind the wall, allowing easier access to FOCIS-10 compatible junior (shorter) LC connectors terminated on 900µm buffered fiber.
Panduit ® Opticom® Fiber Adapter Panels and QuickNet™ Pre-Terminated Cassettes include Sr./Jr. Adapters.
LC Sr./Sr. Simplex Adapter (SM)
LC Sr./Jr. Simplex Adapter (SM)
Opticom ® LC Duplex Fiber Adapter Panel
Mini-Com ® LC Sr./Jr.
Adapter Module
LC Sr./Jr.
Duplex Adapter
.46 [11.6]
.27 [6.8]
.51 [12.9]
.46 [11.6] .37
[9.3] .37 [9.3]
.51 [12.9]
.71 [18.0]
.62 [15.8] 1.37
[34.8]
1.05 [26.6]
1.08 [27.4]
1.02 [25.8]
1.15 [29.1]
.27 [6.8]
HDCRT
Opticom ® QuickNet™
Cassettes HDCRT Connector
Removal Tool
LC Sr./Sr.
Duplex Adapter
Sr./Sr.
Part Number Adapter Type
Split Sleeve Material
Adapter
Module
Average Insertion Loss^
Return Loss^
^Panduit LC Connector/Adapter connection.
**For other colors, replace suffix EI or BU with EI (Electric Ivory), BU (Blue), IG (International Gray), WH (White), TG (Technical Gray), BL (Black), AW (Arctic White), IW (Off White) or EW (European White).
FADSLCEI-L Multimode Duplex Phosphor Bronze Electric Ivory N/A
.1dB
>20dB
>40dB
FADSLCAQ-L 10Gig™ Multimode Duplex Phosphor Bronze Aqua N/A
FASSLCZAQ-L 10Gig™ Multimode Simplex Zirconia Ceramic Aqua N/A
FADSLCZAQ-L 10Gig™ Multimode Duplex Zirconia Ceramic Aqua N/A
FASSLCZBU-L Singlemode Simplex Zirconia Ceramic Blue N/A
FADSLCZBU-L Singlemode Duplex Zirconia Ceramic Blue N/A
LC Adapter Modules
.1dB >20dB
>40dB
CMDSLCEI Multimode Duplex Phosphor Bronze Electric Ivory Various**
CMDSAQLCBL 10Gig™ Multimode Duplex Phosphor Bronze Aqua Black
Black
Various**
CMDSAQLCZBL 10Gig™ Multimode Duplex Zirconia Ceramic Aqua
CMDSLCZBU
Sr./Jr.
Part Number
FADJLCEI-L
FADJLCAQ-L
FASJLCZAQ-L
FADJLCZAQ-L
FASJLCZBU-L
FADJLCZBU-L
CMDJLCEI
CMDJAQLCBL
CMDJAQLCZBL
CMDJLCZBU Singlemode Duplex Zirconia Ceramic Blue
LC Adapters s e l e c t i o n i n f o r m a t i o n
3.91 [99.4]
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT CANADA
Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK cs-emea@panduit.com Phone: 44.20.8601.7200
PANDUIT JAPAN
Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020
PANDUIT LATIN AMERICA
Jalisco, Mexico cs-la@panduit.com Phone: 52.33.3777.6000
DRAWING REV. DATE DRWN. APP. REMARKS
38601
38601 .16 8/22/13 BAL JB Removed Tape Seperator
Comtran Cable LLC 330A Turner Street South Attleboro, MA 02703-7714
(P) 508-399-7004
(F) 508-399-7360 www.ComtranCorp.com
Design Specification Category 6 Plenum UTP
Construction: Compliance:
* Conductors: 23 AWG Solid Bare Copper per ASTM B-3 * ETL Verified ANSI/TIA-568-C.2 Cat 6
* Insulation: Fluoropolymer * UL Subject 444 Communications Cables
* Pair Assembly: Color Coded Conductors twisted to varying lays * UL Listed type CMP
* Cable Assembly: 4 Pairs cabled to form a round core * NFPA 262 Plenum Flame Test (UL910)
* Jacket: Color Coded Plenum PVC * NEC Article 800
Nominal OD = .190” * c(UL) Type CMP
*Ripcord: Ripcord provided under jacket * ICEA S-102-700
(Increasing/Decreasing Footage Markers Provided) * California State Fire Marshal
* RoHS Compliant
Features: Common Applications:
* Superior 4 pair balance for increased margins * Gigabit Ethernet (1000Base-T)
* Low skew and Propagation delay * Multimedia & ISDN
* Small compact round design * High speed Voice/Data applications
* Extended Bandwidth (increased Headroom) * 1.2 Gbps Ethernet
* Excellent Cross Talk characteristics * Broadband Video
* Custom Print legends, Put-up’s and Special colors per request * Desktop Publishing
* Video Conferencing/Imaging
Category 6 Electricals (per ANSI/TIA 568-C.2)
(Information Subject to change without notice)
Part# Color
34277 Green
34481 Yellow
34932 Gray
35334 Red
35675 Violet
38600 Blue
38601 White
Char. Impedance Return Loss Attenuation NEXT PSNEXT ACRF PSACRF
Freq. (Ohms) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB/100m)
(MHz.) (+/-15) (Min) (Max) (Min) (Min) (Min) (Min)
1 100 20 2 74.3 72.3 67.8 64.8
4 100 23 3.8 65.3 63.3 55.7 52.7
8 100 24.5 5.3 60.8 58.8 49.7 46.7
10 100 25 6 59.3 57.3 47.8 44.8
16 100 25 7.6 56.3 54.3 43.7 40.7
20 100 25 8.5 54.8 52.8 41.7 38.7
25 100 24.3 9.5 53.3 51.3 39.8 36.8
31.25 100 23.6 10.7 51.9 49.9 37.9 34.9
62.5 100 21.5 15.4 47.4 45.4 31.8 28.8
100 100 20.1 19.8 44.3 42.3 27.8 24.8
125 100 19.4 22.4 42.9 40.9 25.8 22.8
155.52 100 18.8 25.2 41.4 39.4 23.9 20.9
175 100 18.4 26.9 40.7 38.7 22.9 19.9
200 100 18 29 39.8 37.8 21.7 18.7
250 100 17.3 32.8 38.3 36.3 19.8 16.8
Mutual Cap. = 14pf/ft DC Res.= 7.1 Ω/100m
Propagation Delay Skew: 45 ns/100m (max)
Operating Temperature: -10c to 75c
ACR (min) @ 100 MHz = 24.1dB/100m
ACR (min) @ 200 MHz = 10.0 dB/100m
Nominal Velocity of Propagation (NVP) = 70%
Hubbell’s Surface Mount Boxes are designed to facilitate today’s most demanding workstation outlet needs. The ISB1 and ISB2 are single and 2-port versions allowing for a wide variety of Hubbell data, audio/video and fiber connectivity.
The surface mount boxes are ideal for open office, compact surface mount environments, and retrofits to support data, voice, and multimedia applications. All surface mount boxes can be mounted with supplied surface mounting screws or double-sided adhesive tape.
www.hubbell-premise.com
FEATURES
| Low-profile design |
| Accepts Hubbell HJ and HXJ jacks and audio/ |
video keystone connectors
| Available in five color options |
| ADA compliant |
| Ability to mount to multiple surfaces: |
| Standard electrical boxes |
| Hubbell Raceway |
| RE-BOX® |
| CP enclosure |
| Rack rail |
| Desktops, walls, and modular furniture |
STANDARDS
| UL and cUL listed |
| ANSI/TIA/EIA-606A compliant |
Surface Mounting
Accepts Standard Jacks, Fiber and AV Connections
ADA Compliant
RoHS Compliant
Flexibility Easy cover latches allow for simple moves, adds and changes
Safety Tamper resistant screw located behind the faceplate label field
Installation Ease Bases include tie-wrap anchor points at all cable entrances
APPLICATIONS
| Open office environments |
| Compact surface mount environments |
| Retrofits to support data, voice, and multimedia applications |
Surface Mount Boxes, 1- and 2-Port
POLYTRAK® Raceway Compatibility Chart
Series PP PB
ISB1 *
ISB2 *
*Use PB3REDA transition fitting.
SPECIFICATIONS
Provided with double-sided tape and mounting screws for easy installation
Constructed with a high impact resistant, flame retardant polymer
Base includes tie wrap anchors at rear cable entry point for 4" cable ties (included)
Surface box cover features easy-to-remove knockouts to accommodate Hubbell Raceway
ISB1OW
(loaded)
ISB2OW
(loaded)
HUBBELL PREMISE WIRING COPPER
HUBBELL PREMISE WIRING COPPER
DIMENSIONSORDERING INFORMATION
RELATED PRODUCT
ISB Surface Mount Boxes, 1- and 2-port Color 1-Port 2-Port
Almond ISB1AL ISB2AL
Black ISB1BK ISB2BK
Electric Ivory ISB1EI ISB2EI
Gray ISB1GY ISB2GY
Office White ISB1OW ISB2OW
White ISB1W ISB2W
Premise Wiring www.hubbell-premise.com
Hubbell Premise Wiring • Hubbell Incorporated (Delaware) • 23 Clara Drive • Suite 103 • Mystic, CT 06355 • Phone (800) 626-0005 • FAX (860) 535-8328 Printed in U.S.A. Specifications subject to change without notice.
® is a registered trademark of Hubbell Incorporated. PLDC012 03/12
2.38
0.55 1.30
0.18 0.42
(1.77)
1.05 1.08
0.22
0.68
0.36 0.36 0.58
1.77
0.43 0.18
2.38
1.36
0.39
2.30
0.24
1.82
0.67
0.24
0.42
0.68
0.22
1.081.05
0.37 0.58 0.370.580.39
HJ and HXJ Jacks Category 6, 6A and 5e
UOM Category 5e Category 6 Category 6A
1 per bag/carton of 25 HXJ5Exx* HXJ6xx* HJ6Axx**
25 per bag/carton of 1 HXJ5Exx25 HXJ6xx25 HJ6Axx25** xx = Color: AL (Almond), BK (Black), B (Blue), BN (Brown), EI (Electric Ivory), GL (Gold), GY (Gray), GN (Green), LA (Light Almond), OW (Office White), OR (Orange), P (Purple), R (Red), TI (Telco Ivory), W (White) and Y (Yellow).
Light Almond is the same color as Office White.
*Brown, Gold and Purple available as 25-pack only.
**Not available in Telco Ivory.
Patch Cords Category 6, 6A and 5e
UOM Category 5e Category 6 Category 6A
1 patch cord HC5Exxyy HC6xxyy HC6Axxyy xx = Color: BK (Black), B (Blue), GY (Gray), GN (Green), OR (Orange), P (Purple), R (Red), W (White) and Y (Yellow). See color chart in technical section.
yy = Standard Length: 01 (1'), 03 (3'), 05 (5'), 07 (7'), 10 (10'), 15 (15'), 20 (20').
MTO lengths: 25', 30', 35', 40', 45', 50', 55', 60', 75', 80', 85', 90', 95', and 100'.
1-Port
2-Port
VELCRO® is a registered trademarks of Velcro Industries B.V.
C24206RHPL
MAC DILL BASE
EMERGENCY RESPONSE
JUNCTION BOX FOR
HOUSING BTXWAC
PADLOCK
DEVICE
James
James
Line
Robert A. Rolley, P.E.
MacDill Air Force Base
EMERGENCY RESPONSE NOTIFICATION SYSTEM
(NVZR 16-0065)
Prepared for:
R.M. Williams Construction
504 S. Moddy Ave.
Tampa, Florida 33609-3342
By:
7759 West Waters Ave.
Tampa, Florida 33615
SUBSTITUTION REQUEST
EST – HYPERSPIKE SPEAKER ARRAYS
Resubmitted April 11, 2017
Table of Contents
TAB 1
TAB 2
EST Hyperspike “HPSA” Cutsheets .............................................................................................. 1 - 1
“Crown” Amplifier Cutsheets ...................................................................................................... 1 - 7
“Crown” Amplifier Specifications............................................................................................... 1 – 9
Edwards ANS25MD*2 Audio Message Storage Unit Cutsheets ................................................ 1 - 10
Interface Specification – Edwards Hyperspike Interface with Monaco BT-XWAC..................... 1 - 18
Mounting Detail – Pole Mount Bracket, ECC – UTC ................................................................... 1 - 22
Mounting Detail – HS-Series Emitter Pole Mount ..................................................................... 1 - 24
American Signal E-Class HPSA Cutsheets ...................................................................................... 2 - 1
TAB 3
EST Hyperspike vs American Signal Comparison .......................................................................... 3 - 1
TAB 4
TAB 5
Sound Pressure Level (SPL) Mapping ............................................................................................ 4 - 1
Drawing ES101 – Giant Voice Tower Locations......................................................................... ES101
Drawing ES102 – Proposed Sound Level dBA Map.................................................................... ES102
Drawing ES103 – Proposed Intelligibility Level STI Map............................................................ ES103
EST Hyperspike “HPSA” -Technical Guide ................................................................................... 5 - i
TAB 1
EST Hyperspike “HPSA” Cutsheets ................................................Pages 1 - 6 "Crown" Amplifier Cutsheets ............................................................Pages 7 - 8 "Crown" Amplifier Specifications ......................................................Page 9 Edwards ANS25MD*2 Audio Message Storage Unit Cutsheets......Pages 10 - 17 Interface Specification - Edwards Hyperspike Interface with Monaco BT-XWAC...............................................................Pages 18 - 21 Mounting Detail – Pole Mount Bracket, ECC – UTC.........................Pages 22 - 23 Mounting Detail – HS-Series Emitter Pole Mount ............................Pages 24 - 25
D A T A S H E E T 85001-0637
11-08-13
EST Catalog u EST3-Sixty -- Mass Notification
Lightweight High Power Speaker Arrays HS Series
Overview EST brand HS Series High Power Speaker Arrays (HPSA) em-ploy exclusive HyperSpike® technology to deliver lightweight and acoustically sophisticated solutions for for outdoor Emergency Communication Systems/Mass Notification Systems/Life Safety Systems (ECS/MNS/LSS) installations. These rugged outdoor-rated units are among the industry's smallest in physical size, yet they reproduce some of the clearest (up to 0.91 STI, source-dependant) and loudest (up to 138 dBA-fast @ 1m) audio signals available. Loudspeaker heads are as small as 13.2" (33.52 cm) in diameter and 25.25” (64.13 cm) in height. A single panel unit weighs as little as 16 lb (7.3 kg).
HS Series loudspeakers are available in a number of different con-figurations, from one panel configurations that provide a relatively narrow sound dispersion, to five-panel configurations with full 360° sound projection.
The unique design of HS Series loudspeakers allow for a 100 percent up-time duty cycle — when powered from an AC source, they can be powered and ready to perform 24/7. This makes them ideally suited for daily activation, as well as emergency use.
HS Series HPSAs can he permanently installed, or can be con-figured for portable use. Units come standard with an internal inverter/charger system that can operate the HPSA from the 24 VDC battery compliment.
Each HS Series HPSA loudspeaker has a remotely-mounted Electronics Control Cabinet (ECC) that can be installed indoors or outdoors. These house the audio power amplifiers as well as control and power equipment. The lockable reinforced fiberglass cabinets are rated NEMA 3, 3R, 3S, 4, 4X, 12, 12K and 13. They come ready to interface with the EST3-Sixty Emergency Commu-nication Platform.
Standard Features
• Intelligible audio performance (up to 0.91 STI)
• 24/7/365 duty cycle
• 360, 230, 185 and 120 degree dispersion pattern options
• 320 to 6400 watt configurations
• Easy installation – mounts to standard 2-inch diameter mast
• Lightweight loudspeaker heads – as low as 16 pounds (7.3 kg)
• Rugged outdoor construction
• Reliable and supervised interfaces to the EST3-Sixty platform
• Includes a 8 ft (2.44 m) flexible weathertight wiring conduit
1 - 1
Application Any outdoor facilities, such as:
• Universities, Colleges & High Schools
• Health care campuses
• Quads
• Parking lots
• Military bases
• Force protection
• Large ships
• Piers
• Docks
• Industrial complexes
• Refineries
• Power plants
• Air fields
• Stadiums
• Golf Courses
• Camp Grounds
• Amusement parks
• Open mines
• Weather warning systems
• Flood warning systems
• Civil defense
Installation For optimal performance and safety when installing in permanent locations, High Power Speaker Arrays (HPSAs) loudspeakers should be mounted 35 to 55 feet (10.7 to 16.8 m) above grade on a pole, building or other structure. For portable or vehicle-mounted applications, the loudspeaker head should be at least 20 feet (6.1 m) above grade and away from people. For all installations, it is also key to have clear, open space around the speaker head.
HPSA output is best via line-of-sight.
The factory assembled and tested Electronics Control Cabinets (ECCs) contain the HPSA interface terminals, transient protectors, and components to support easy, clean, and supervised connec-tion to the EST3-Sixty platform. This makes for simple and intuitive control of the units from a single control point or multiple locations.
The ECCs contain the power amplifier(s), digital signal processor, and power inverter system. Batteries are maintained in a Ready State by a temperature-compensated charging system.
The ECCs can be mounted inside or outside. Mounting options include pole, flange (wall), or pedestal. Heaters and ventilation units can also be ordered when required. When outdoor mounting, ECC and battery cabinets can be mounted below the loudspeaker head for easy access, but high enough to prevent vandalism. The ECC can hold one or two replaceable power amplifiers. Cabinets are equipped with tamper switches.
Internal displays and diagnostic LEDs simplify maintenance. HPSA status is also transmitted to the EST3-Sixty platform. A GFCI-pro-tected convenience outlet is provided with ECCs to aid in servic-ing. All ECC power is protected with circuit breakers. Exterior wiring to and from the ECC is protected by transient protectors.
Typically, the HS Series HPSA provides the EST3-Sixty platform with the following signals:
• Activation Confirmation
• Incoming AC failure
• Inverted AC failure
• Audio failure
• DC failure
• Door tamper
Units come standard with a one year warranty. An optional second year of additional coverage may be purchased at the time of the initial order. Warranties exclude batteries, which carry a 90-day warranty.
US Military Specifications Loudspeaker Head
Random vibration MIL-STD 810F, Method 514.4 Shipboard vibration MIL-STD 167-1A Shipboard shock MIL-STD-910D, Class 1 SRS shock MIL-STD-810F, Method 516.5 Rain MIL-STD-810F, Method 506.4 Operating Humidity MIL-STD-810F, Method 507.4 Salt fog MIL-STD-810F, Method 509.4
1 - 2
Typical Deployment
Specifications Loudspeakers
Speaker Panels Sound Dispersion 1600 Class 3200 Class 6400 Class
Output
5 Panel Array 360° 1600 Watts 3200 Watts 6400 Watts 3 Panel Array 230° 960 Watts 1920 Watts 3840 Watts 2 Panel Array 185° 640 Watts 1280 Watts 2560 Watts 1 Panel Array 120° 320 Watts 640 Watts 1280 Watts
Weight
5 Panel Array 360° 48 lb. (21.77 kg) 96 lb (43.55 kg) 192 lb (87.09 kg) 3 Panel Array 230° 31 lb (14.06 kg) 62 lb (28.12 kg) 124 lb (56.25 kg) 2 Panel Array 185° 24 lb (10.89 kg) 48 lb (21.77 kg) 96 lb (43.55 kg) 1 Panel Array 120° 16 lb (7.26 kg) 32 lb (14.52 kg) 64 lb (29.03 kg)
Dimensions Each Diameter 13.2" (33.52 cm) 13.2" (33.52 cm) 13.2" (33.52 cm) Each Height 25.25" (64.13 cm) 40.50" (102.87 cm) 81" (205.74 cm)
Environmental Operating temperature: -40 °F to 167 °F (-40 °C to 75 °C); Humidity: 0% to 95% (non-condensing).
Electronics Control Cabinet
Dimensions 70" x 30" x 12"
177.8 x 76.2 x 30.5 cm 70" x 30" x 12"
177.8 x 76.2 x 30.5 cm 70" x 60" x 12"
177.8 x 152.4 x 30.5 cm Weight (without batteries) 242 lb (109.8 kg) 248 lb (112.5 kg) 496 lb (225.0 kg)
Sound Dispersion Patterns
5-Panel Array 360° Sound Dispersion
Structure
3-Panel Array 230° Sound Dispersion
S tr uc tu re
2-Panel Array 185° Sound Dispersion
Structure
1-Panel Array 120° Sound Dispersion
NEMA 4X
Enclosures
AC Mains
Can be mounted indoors or outdoors
HS Series Speaker Head
Outdoor use only
Audio from EST3-Sixty
Control from EST3-Sixty/ FireWorks
Connection Media/Method
Electronic Control Cabinet
(ECC)
Battery Cabinet
(24 VDC)
1 - 3
High Power Speaker Array Assemblies HPSA Assemblies are AC powered with DC backup. They come with a lockable NEMA 4 Electronics Control Cabinet (ECC) that holds the amplifier and battery charger, and a lockable NEMA 4 battery enclosure. Enclosures are equipped with tamper switches. Loudspeak-ers come pre-assembled with an eight foot (2.4 meter) ¾-inch liquid-tite flexible conduit whip and wire leads. Batteries and battery enclosures are ordered separately.
High Power Speaker Array Assemblies
Model Number Output Sound Dispersion Active Panels
Speaker Head ColorWith 230V/50Hz inverter/charger With 230V/50Hz inverter/charger
1600 Watt Class
MN-HS16T5P MN-HS16T5P-E 1600 Watts 360° 5 of 5
Tan MN-HS16T3P MN-HS16T3P-E 960 Watts 230° 3 of 5 MN-HS16T2P MN-HS16T2P-E 640 Watts 185° 2 of 5 MN-HS16T1P MN-HS16T1P-E 320 Watts 120° 1 of 5 MN-HS16G5P MN-HS16G5P-E 1600 Watts 360° 5 of 5
Gray MN-HS16G3P MN-HS16G3P-E 960 Watts 230° 3 of 5 MN-HS16G2P MN-HS16G2P-E 640 Watts 185° 2 of 5 MN-HS16G1P MN-HS16G1P-E 320 Watts 120° 1 of 5
3200 Watt Class
MN-HS32T5P MN-HS32T5P-E 3200 Watts 360° 5 of 5
MN-HS32T3P MN-HS32T3P-E 1920 Watts 230° 3 of 5 MN-HS32T2P MN-HS32T2P-E 1280 Watts 185° 2 of 5 MN-HS32T1P MN-HS32T1P-E 640 Watts 120° 1 of 5 MN-HS32G5P MN-HS32G5P-E 3200 Watts 360° 5 of 5
MN-HS32G3P MN-HS32G3P-E 1920 Watts 230° 3 of 5 MN-HS32G2P MN-HS32G2P-E 1280 Watts 185° 2 of 5 MN-HS32G1P MN-HS32G1P-E 640 Watts 120° 1 of 5
6400 Watt Class
MN-HS64T5P MN-HS64T5P-E 6400 Watts 360° 5 of 5
MN-HS64T3P MN-HS64T3P-E 3840 Watts 230° 3 of 5 MN-HS64T2P MN-HS64T2P-E 1280 Watts 185° 2 of 5 MN-HS64T1P MN-HS64T1P-E 640 Watts 120° 1 of 5 MN-HS64G5P MN-HS64G5P-E 6400 Watts 360° 5 of 5
MN-HS64G3P MN-HS64G3P-E 3840 Watts 230° 3 of 5 MN-HS64G2P MN-HS64G2P-E 1280 Watts 185° 2 of 5 MN-HS64G1P MN-HS64G1P-E 640 Watts 120° 1 of 5
Protective Covers MN-HS16GPC Gray HS Series 1600 Watt class optional protective cover.
MN-HS32GPC Gray HS Series 3200 Watt class optional protective cover MN-HS64GPC Gray HS Series 6400 Watt class optional protective cover MN-HS16TPC Tan HS Series 1600 Watt class optional protective cover.
MN-HS32TPC Tan HS Series 3200 Watt class optional protective cover MN-HS64TPC Tan HS Series 6400 Watt class optional protective cover
Warranty Programs MN-HS16EXWARR2 HS Series 1600 Watt class extended warranty - 2 years total. Must be ordered when HPSA is ordered.
MN-HS32EXWARR2 HS Series 3200 Watt class extended warranty - 2 years total. Must be ordered when HPSA is ordered.
MN-HS64EXWARR2 HS Series 6400 Watt class extended warranty - 2 years total. Must be ordered when HPSA is ordered.
Batteries and Solar Charging MN-HSBATT140 HS Series ECC Standard Battery set. 140 AH SLA. 2 batteries required for each ECC. Replace in pairs.
MN-HSBHK1X
HS Series Battery compliment heating blankets (set of 2) for use with MN-HSBX1 Extended Battery Enclosure. 120 VAC.
Requires MN-HSECCH1.
MN-HSBHK1S HS Series Battery compliment heating blankets (set of 2). 120 VAC. Requires MN-HSECCH1. Two used for MN-HS64 Series.
MN-HSBX1
HS Series ECC Battery Extension enclosure (without batteries). Includes tamper switch, battery shelf and cabling. Can be mounted to the side or below the ECC primary battery enclosure.
Accessories
1 - 4
Amplifiers
MN-HSECC1
MN-HS16 Class lockable NEMA 4 amplifier, 110V/60Hz. inverter/battery charger and electronics enclosure, lockable NEMA 4 battery enclosure (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup. Batteries and accessories are ordered separately.
MN-HSECC2
MN-HS32 Class lockable NEMA 4 amplifier, 110V/60Hz. inverter/battery charger and electronics enclosure, lockable NEMA 4 battery enclosure (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup. Batteries
MN-HSECC4
MN-HS64 Class lockable NEMA 4 amplifier, 110V/60Hz. inverter/battery charger and electronics enclosures, lockable NEMA 4 battery enclosures (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup.
Batteries and accessories are ordered separately.
MN-HSECC1-E
MN-HS16 Class lockable NEMA 4 amplifier, 230V/50Hz. inverter/battery charger and electronics enclosure, lockable NEMA 4 battery enclosure (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup. Batteries
MN-HSECC2-E
MN-HS32 Class lockable NEMA 4 amplifier, 320V/50Hz. inverter/battery charger and electronics enclosure, lockable NEMA 4 battery enclosure (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup. Batteries
MN-HSECC4-E
MN-HS64 Class lockable NEMA 4 amplifier, 230V/50Hz. inverter/battery charger and electronics enclosures, lockable NEMA 4 battery enclosures (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup.
Batteries and accessories are ordered separately.
Heating and Ventilation MN-HSECCFAN1 HS Series ECC Top-mount ventilation fan system with side louvers. 115 VAC. Changes ECC rating to NEMA 3R MN-HSECCFAN1-E HS Series ECC Top-mount ventilation fan system with side louvers. 230 VAC. Changes ECC rating to NEMA 3R
MN-HSECCH1
HS Series ECC Cabinet heater system kit (120 VAC). Provides terminals for battery heater blanket kits. One used for MN-HS16 & MN-HS32 Series. Two used for MN-HS64 Series.
MN-HSECCH1-E
HS Series ECC Cabinet heater system kit (230 VAC). Provides terminals for battery heater blanket kits. One used for MN-HS16 & MN-HS32 Series. Two used for MN-HS64 Series.
MN-HSECCPED1
HS Series ECC Housekeeping Pedestal Mount Kit (4"). Used when wall-mounting MN-HS16 or MN-HS32 Series ECC. 2 required if wall-mounting MN-HS64 Series ECCs.
Audio Sofware MN-AUDSOF1 HS Series audio optimization software package
Modeling Services
MN-HSEMD12
HS Series EASE modeling exterior direct/reflected energy. Up to (12) 3D buildings overlaid on Google earth map or provided PDF/CAD site topology drawing. Modeling based on 125-2Khz band and provide medium resolution graphics with 3dB steps in propagation for up to (6) acoustic device/array locations onto chloropleth map. Scale limit of this offer is for 4 million square feet venue.
MN-HSEMDNB
HS Series EASE modeling exterior direct energy only (no 3D buildings) overlaid on Google earth map or on provided PDF/CAD site topology drawing. Modeling based on 125-2Khz band and provide medium resolution graphics with 3dB steps in propagation or up to (4) acoustic device/array locations onto chloropleth map. Scale limit of this service is in 2 million square feet increments.
MNHSEMDQ
HS Series Ease modeling exterior direct/reflected energy. Over 12 3D buildings overlaid on Google earth map or provided PDF/CAD site topology drawing. Modeling based on 125-2Khz band and provide medium resolution graphics with 3dB steps in propagation for system required acoustic device/array locations onto chloropleth map. Contact Edwards Customer Service for quote.
MN-HSEMN12
HS Series EASE modeling interior direct/reflected energy. Up to (12) interior 3D substructures overlaid on provided PDF/CAD plan view drawing. Modeling based on 125-2Khz band and provide medium resolution graphics with 3dB steps in propagation for up to (10) acoustic device/array locations onto chloropleth map. Scale limit of this offer is for 250,000 square foot venue.
MN-HSEMN24
HS Series EASE modeling interior direct/reflected energy. Up to (24) interior 3D substructures overlaid on provided PDF/CAD plan view drawing. Modeling based on 125-2Khz band and provide medium resolution graphics with 3dB steps in propagation for up to (16) acoustic device/array locations onto chloropleth map. Scale limit of this offer is for 500,000 square foot venue.
MN-HSEMNQ
HS Series EASE modeling interior direct/reflected energy. Over 24 interior 3D substructures overlaid on provided PDF/CAD plan view drawing.