Attachment 6_Supporting Docs.pdf

PDF 47 MB Posted

Attached to
PKA-Giant Voice Equipment -6 CS (Amendment 6)
Solicitation number
FA481426Q0072
Issued by

About this file

This is a supporting documentation file (Attachment 6) containing manufacturer product specifications and technical interface documentation for the MacDill AFB Base Emergency Response Notification System project.

The attachment includes detailed product specifications for fiber optic cable infrastructure components, including Corning 12-strand single-mode loose tube gel-free cable (part number 012ESF-T4101D20) with riser rating suitable for aerial, duct, and indoor applications; Corning buffer tube fan-out kits for field termination; Panduit LC OptiCam pre-polished fiber optic connectors with zirconia ceramic ferrules compatible with 9/125mm single-mode fiber; and various fiber adapter panels and cabling infrastructure. The documentation also contains installation instructions for Edwards ANS25MD/ANS50MD/ANS100MD voice evacuation interface systems, specifying 25-100 watt amplifier outputs, battery backup requirements (24V 7AH to 24AH), and detailed wiring diagrams for Class A and Class B speaker circuit configurations. Additionally, the file includes an Interface Specification document (Revision A, dated April 10, 2017) defining operational requirements between the Edwards Hyperspike high-powered speaker array and Monaco BT-X WAC mass notification communicator, covering status monitoring via eight auxiliary relay zones, live voice activation through line-level audio connections, and pre-recorded message triggering capabilities. A pole-mount bracket assembly drawing and bill of materials for Ultra Electronics USSI mounting kit components are also provided. Email correspondence from Edwards representatives confirms amplifier efficiency exceeding 90%, total harmonic distortion below 0.1%, and frequency response capabilities from 100Hz to 20KHz, meeting system performance requirements for the Giant Voice replacement project at MacDill AFB.

View the file

Other files

File Type Posted
Giant Voice Solicitation FA481426Q0072 Questions and Answers.docx DOCX document
Notice to Offerors_Solicitation Reopening and Scope Revision.pdf PDF
Attachment 6_Technical Reference Materials.pdf PDF
Attachment 2_Provisions and Clauses_FA481426Q0072.pdf PDF
Attachment 5_Supporting Pictures.pdf PDF
Attachment 4_Previous Q_A (for reference only).pdf PDF
Attachment 3_WD_No 2015_571_Rev_No31.pdf PDF
Combined Synopsis Soliciation FA481426Q0072 Amendment 6.pdf PDF
Attachment 1_Statement of Work (SOW) _Giant Voice System_10Sept2026 (Final).pdf PDF
Notice to Offerors_Solicitation Reopening and Scope Revision.pdf PDF
Attachment 4_Questions and Answers (Final-updated).pdf PDF
Attachment 1 - Statement of Work SOW - MacDill Giant Voice System-5Mar20226 -_Amended_25 Jun 26.pdf PDF
Combined Synopsis Soliciation FA481426Q0072 Amendment 5.pdf PDF
Combined Synopsis Soliciation FA481426Q0072 Amendment 4.pdf PDF
Attachment 5_Pictures.pdf PDF
Attachment 4_Questions and Answers (Final).pdf PDF
Combined Synopsis Soliciation RFQ FA481426Q0072 - Amendment 3.pdf PDF
Attachment 4 - Vendors Questions - PKA-Giant Voice Equipment -6 CS -FA481426Q0072.pdf PDF
Combined Synopsis Soliciation RFQ FA481426Q0072 - Amendment 2.pdf PDF
Vendor Questions - PKA-Giant Voice Equipment -6 CS -FA481426Q0072.pdf PDF
Attachment 3 - Davis-Bacon Act WD - FL20260208.pdf PDF
Combined Synopsis Soliciation RFQ FA481426Q0072 - Amendment 2.pdf PDF
Attachment 2 - Provision and Clauses - FA481426Q0072_2.pdf PDF
Attachment 1 - Statement of Work SOW - MacDill Giant Voice System-5Mar20226 - Amendment 2.pdf PDF
Combined Synopsis Soliciation RFQ FA481426Q0072_ Amendment 1.pdf PDF
1 Statement of Work (SOW) - MacDill Giant Voice System-5Mar20226.pdf PDF
Combined Synopsis Soliciation RFQ FA481426Q0072.pdf PDF
Provision and Clauses_FA481426Q0072.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 4

1. Fiber & Conductors

2. Giant Voice Equipment Cut Sheet

3. MNS Control Centers

4. RPR SUS Base Emergency Response Notification Syst As-Builts

5. E-603 RPR SUS Base Emergency Response Notification Syst As-Builts

Manufacturer / Part Number Item Description

Corning / 012ESF-T4101D20 12 Strand SM Loose Tube

Corning / FAN-BT25-12 Corning Fan Out Kit SM

Panduit / FLCSSCBUY LC Panduit SM Fiber Optic Connector

Panduit / FWME2 Wall Mount Fiber LIU

Panduit / FAP12WBULCZ 12 Port SM LC Fiber Adapter Panel

Comtran / 38600 Category 6 Plenum Cabling Blue

Hubbell / ISB2W Surface Mount Box 2-Port White

Hubbell / HXJ6W Category 6 Jack White

Submittal Table of Contents

MacDill AFB - Mass Notification

Part Number: 012ESF-T4101D20

Cross Section of Part Number: 012ESF-T4101D20

FR / UV-Resistant Outer Jacket

Ripcord

Fiber

Buffer Tube

Dielectric Strength Members

Corning FREEDM® LST™ gel -free cables are flame -retardant, indoor/outdoor, riser -rated cables designed for interbuilding and intrabuilding backbones in aerial, duct and riser applications. With a riser rating, there is no need for a transition splice when entering the build-ing. Available in a compact design, these cables are protected against water penetration by innovative wa-terblocking tapes and yarns that swell to absorb water.

Waterblocking without the use of messy gels provides more efficient and craft -friendly cable preparation, allows easier cable access and simplifies the use of buffer tube fan -out kits. The buffer tubes and fibers in each tube are color coded for quick, easy identification.

Note: This cable is available in 12 different jacket colors

– blue, orange, green, brown, slate, white, red, black, yel-low, violet, rose and aqua. The colored jacket allows for easy visual identification of the cables while still providing all of the required environmental protection of an indoor/ outdoor cable jacket. Black is the standard jacket color using the part numbers shown here. Contact Customer Care at 1 -800 -743 -2675 to order other color options.

Features and Benefits Riser rating No transition splices when entering buildings

Gel-free waterblocking technology Craft-friendly cable preparation

Color-coded fibers Quick and easy identification

All-dielectric construction Requires no grounding or bonding

UV-resistant, flame-retardant jacket Rugged, durable and easy to strip

Standards Approvals and Listings National Electrical Code®

(NEC®) OFNR, CSA OFN

FT-4

Common Installations Outdoor lashed aerial and duct; indoor vertical riser and general purpose hori-zontal according to National Electrical Code (NEC) Article 770

FREEDM® LST™ Loose-Tube, Gel-Free Cable, Riser 12 F, Single-mode (OS2)

Product Specification 012ESF-T4101D20_NAFTA_AEN Page 1 | Revision date 2015-06-18 jhenderson

Rectangle

Standards Design and Test Criteria ANSI/ICEA S-104-696

Specifications

General Specifications Environment Indoor/Outdoor Cables

Application Aerial, Direct Buried, Duct, General Purpose Horizontal, (Vertical Riser)

Cable Type Loose Tube

Product Type Dielectric

Flame Rating Riser (OFNR)

Fiber Category Single-mode (OS2)

Temperature Range Storage -40 °C to 70 °C (-40 °F to 158 °F)

Installation -10 °C to 60 °C (14 °F to 140 °F)

Operation -40 °C to 70 °C (-40 °F to 158 °F)

Cable Design Fiber Count 12

Fiber Coloring Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua

Fibers per Tube 12

Number of Tube Positions 1

Number of Active Tubes 1

Tensile Strength Elements and/or Armoring - Layer 1 Dielectric strength members

Tensile Strength Elements and/or Armoring - Layer 2 Water-swellable dielectric strength members

Number of Ripcords 1

Outer Jacket Material Flame-Retardant, UV-Resistant

Outer Jacket Color Black

Page 2 | Revision date 2015-06-18

Mechanical Characteristics Cable Weight 56 kg/km (38 lb/1000 ft)

Nominal Outer Diameter 7.4 mm (0.29 in)

Max. Tensile Strength, Short-Term 1350 N (300 lbf)

Max. Tensile Strength, Long-Term 400 N (90 lbf)

Min. Bend Radius Installation 111 mm (4.4 in)

Min. Bend Radius Operation 37 mm (1.5 in)

Chemical Characteristics

RoHS Free of hazardous substances according to RoHS 2002/95/

EG

Fiber Specifications

Optical Characteristics (cabled) Fiber Name Single-mode (OS2)

Fiber Category G.652.D

Fiber Code E

Performance Option Code 01

Wavelengths 1310 nm / 1383 nm / 1550 nm

Maximum Attenuation 0.4 dB/km / 0.4 dB/km / 0.3 dB/km

Ordering Information Part Number 012ESF-T4101D20

Product Description FREEDM® LST™ Single-Tube, Gel-Free Cable, 12 F, Single-mode (OS2)

EAN Code 4042673236894

Page 3 | Revision date 2015-06-18

Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA 800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcomm A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks.

All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified.

© 2015 Corning Optical Communications. All rights reserved.

Buffer Tube Fan-Out Kits A LANscape® Solutions Product

Applications

• Field termination of loose tube cables at indoor or outdoor cross-connects

Description Corning Cable Systems Indoor and Outdoor Buffer Tube Fan-Out Kits are specifically designed for the termination of 6- and 12-fiber buffer tubes. These buffer tube fan-out kits provide the ultimate solution for those users who want to field-install connectors. The kits provide the most compact, easy-to-install fan-out solution requiring no additional hard-ware or space than that required for terminating tight-buffered cables.

Indoor and outdoor kits feature a 900 µm fan-out assembly that is color-coded to match the fiber color scheme. The fan-out assembly is available with 6- or 12-fiber units in lengths of 25 or 47 inches. These different lengths provide the installer the flexibility needed for a variety of hardware options.

Features / Benefits

• Eliminates strain on fibers by isolating them from tensile forces

• Colored fan-out tubing

• Snap-together furcation unit eliminates epoxy for indoor kits

• Compact design

• Quick and easy to install

• Optimized for field termination of cables

• Excellent fiber routing capabilities

• Bend radius protection designed into each unit

• Outdoor kits include additional elements that compensate for wider temperature fluctuations common in outdoor environments

Buffer Tube Fan-Out Kit | Photo LAN365

Corning Cable Systems

Product Specifications

Buffer Tube Fan-Out Kit | Photo LAN49

• Indoor temperature range 0˚ to +70˚C Outdoor temperature range -40˚ to +70˚C

Buffer Tube Fan-Out Kits A LANscape® Solutions Product

To order a buffer tube fan-out kit, first determine the length of tubing required for connector termination, either 25 or 47 inches. Next, determine the number of fibers to furcate.

Length of Number of Fibers Part Number Tubing per Buffer Tube1

Indoor Buffer Tube Fan-Out Kits FAN-BT25-06 25 inches 6 FAN-BT47-06 47 inches 6 FAN-BT25-12 25 inches 12 FAN-BT47-12 47 inches 12

Outdoor Buffer Tube Fan-Out Kits FAN-OD25-06 25 inches 6 FAN-OD47-06 47 inches 6 FAN-OD25-12 25 inches 12 FAN-OD47-12 47 inches 12 Notes 1Refer to cable specifications.

Tool Kit and Tool Kit Consumables Part Number Description TKT-FANBT-A Buffer Tube Fan-Out Assembly Tool Kit includes buffer tube fan-out assembly fixture and buffer tube fan-out kit instructions TKT-FANBT-C Buffer Tube Fan-Out Assembly Consumables Kit includes buffer tube fan-out procedure instructions, buffer tube fan-out clamp, MSDS 411 adhesive, Loctite 411 adhesive, Kimwipes, alcohol wipes, and MSDS alcohol wipes

Corning Cable Systems

Corning Cable Systems LLC • PO Box 489 • Hickory, NC 28603-0489 USA 1-800-743-2675 • FAX: +1-828-901-5973 • International: +1-828-901-5000 • http://www.corning.com/cablesystems Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. Discovering Beyond Imagination is a trade-mark of Corning Incorporated. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified.

© 2000, 2005 Corning Cable Systems. All rights reserved. Published in the USA. LAN-103-EN / June 2005 / pdf

Bottom

Fan-Out AssemblyFurcation Unit

Top

44.5 mm (1.75 in)

7.7 mm (0.303 in)

11.3 mm (0.446 in) 20.1 mm

(0.791 in)

Kit Components | Drawing CPC-220/2/1 Completed Kit Dimensions | Drawing CPC-220/2/2 www.panduit .com

LC OptiCam® Pre-Polished Fiber Optic Connectors S P E C I F I C A T I O N S H E E T

LC OptiCam® Pre-Polished Connectors with Zirconia Ceramic Ferrules 10Gig™ 50/125μm (laser optimized) simplex: FLCSMCXAQY▲ 10Gig™ 50/125μm (laser optimized)

duplex:FLCDMCXAQY
50/125μm simplex:FLCSMC5BLY▲
50/125μm duplex:FLCDMC5BLY
62.5/125μm simplex:FLCSMC6BLY▲
62.5/125μm duplex:FLCDMC6BLY
9/125μm simplex:FLCSSCBUY▲

9/125μm duplex: FLCDSCBUY OptiCam® 1.6/2.0mm Boots 10Gig™multimode

(aqua):FMCBT2AQ-X*
Multimode (black):FMCBT2BL-X
Singlemode (blue):FSCBT2BU-X

OptiCam® 3.0mm Boots 10Gig™multimode

(aqua):FMCBT3AQ-X*
Multimode (black):FMCBT3BL-X
Singlemode (blue):FSCBT3BU-X

*X = Bag of 10 Boots; 100 per carton.

OptiCam® Termination Tooling OptiCam® Termination Kit: FCAMKIT OptiCam® Conversion Kit (upgrades Opti-Crimp® Kit to also terminate OptiCam® Connectors): FPPKIT-CVY Field Polish Kit Upgrade (upgrades Field Polish Kit to also terminate

OptiCam® Connectors):FIELDKITUPG
LC cradles (2 per pkg.):FLCC

LC Fiber Optic Adapters

10Gig™multimode:FADJLCAQ-L*
Multimode:FADJLCEI-L
Singlemode:FADJLCZBU-L

*L = Bag of 50 adapters; 100 per carton.

Mini-Com® LC Adapter Modules

10Gig™multimode:CMDJAQLC**
Multimode:CMDJEILC**
Singlemode:CMDJLCZBU

**Substitute for module color: EI = Electric Ivory, BU = Blue, BL = Black, IW = Off White, AW = Arctic White Opticom® LC Fiber Adapter Panels 6 duplex MM adapters: FAP6WEIDLC 6 duplex SM adapters: FAP6WBUDLCZ 12 duplex MM adapters: FAP12WEIDLC 12 simplex SM adapters: FAP12WBULCZ Opti-Core ® LC Patch Cords

Duplex LC to LC:F^E10-10M‡Y
Simplex LC to LC:F^F10-10M‡Y
Duplex SC to LC:F^E3-10M‡Y
Simplex SC to LC:F^F3-10M‡Y

LC Lock-in Duplex Clip LC lock-in duplex clip: FLCCLIW-X ▲Add -C to simplex connector part numbers for bulk packs of 100 connectors.

^Substitute for fiber type: 6 = 62.5/125μm OM1, 5 = 50/125μm OM2, X = 10Gig™ 50/125μm OM3/OM4 or 9 = 9/125μm OS1/OS2.

‡Substitute for length in meters: 1, 2, 3, 5 or 10.Contact Customer Service for other available lengths.

a p p l i c a t i o n s LC fiber optic connectors are widely used in fiber optic backbone and horizontal applications for high-speed data transmission. Typical applications for LC OptiCam® Connectors include maintenance or emergency restoration of fiber networks and retrofit/initial install in both behind-the-wall (BTW) and in the permanent side of panelized interconnect and cross-connect. LC OptiCam®

Connectors eliminate the need for end face polishing and adhesive providing easier, faster installation, especially in remote areas and confined spaces.

The hand-held OptiCam® Termination Tool gives installers the flexibility to terminate in very close proximity to the application without having to switch tools or find benchtop space.

t e c h n i c a l i n f o r m a t i o n Standards requirements: TIA/EIA-604 FOCIS-10 compatible; exceeds

TIA/EIA-568-B.3 requirements

Fiber compatibility: 62.5/125μm OM1, 50/125μm OM2, 10Gig™ 50/125μm laser optimized OM3/OM4 and 9/125μm OS1/OS2

Fiber cable type: 900μm tight-buffered cable only

Fiber cable size: 1.6mm – 2.0mm and 3.0mm jacketed cable with optional boots

Ferrule type: Zirconia ceramic with a pre-polished fiber stub

Insertion loss: Ceramic: 0.3dB average (multimode and singlemode)

Return loss: Ceramic: >20dB (multimode), >26dB (10Gig™ multimode), >50dB (singlemode) s p e c i f i c a t i o n s LC small form factor (SFF) pre-polished connectors with rear pivot latch shall be TIA/EIA-604 FOCIS-10 compatible and contain a factory-terminated fiber, eliminating field polishing and adhesive. LC pre-polished connectors shall have an average insertion loss of 0.3dB per mated pair for multimode and singlemode fiber. LC pre-polished connectors shall captivate fiber and buffer in one action allowing for up to two re-terminations with no degradation in performance.

k e y f e a t u r e s a n d b e n e f i t s LC OptiCam ® Connectors

Factory pre-polished fiber stub endface

Eliminates inconsistent and time-consuming field polishing to deliver required optical performance; reduces termination time (less than half the time of field polish connectors) and the number of installation tools required

Dual cam design with fiber and buffer clamps

Secures both the fiber and the buffer during the camming step to facilitate consistent termination results; reduces the termination time compared to conventional termination methods Allows up to two re-terminations to achieve optimum termination results; reduces the number of rejected connectors and terminations to provide yield rates approaching 100% for lower installed costs

Translucent housing assembly

Facilitates inspection of the fiber termination quality; results in rapid installations, improved termination yields, and lower installed costs

Non-optical disconnect Maintains data transmission under tensile loads for jacketed cable

Mechanical cable retention Consistently provides higher than industry standard cable retention;

requires no adhesive, speeding installation

Zirconia ceramic ferrules Provide the highest durability for repeated matings

OptiCam® Termination Tool Universal termination tool Secures both fiber and buffer in one action for all OptiCam® Connectors with connector specific cradles (included); ensures fast, consistent, and optimal terminations

Integrated visual termination indicator (VTI)

Provide the highest durability for repeated matings

2.23 [56.6]

.25 [6.35]

[56.6]

(56.6) 2.23

(56.6)

.25 (6.35)

©2015 Panduit Corp.

ALL RIGHTS RESERVED.

FBSP19--WW-ENG

3/2015

LC OptiCam® Pre-Polished Fiber Optic Connectors

WORLDWIDE SUBSIDIARIES AND SALES OFFICES

For a copy of Panduit product warranties, log on to www.panduit.com/warranty

PANDUIT CANADA

Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300

PANDUIT EUROPE LTD.

London, UK cs-emea@panduit.com Phone: 44.20.8601.7200

PANDUIT JAPAN

Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000

PANDUIT SINGAPORE PTE. LTD.

Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575

PANDUIT AUSTRALIA PTY. LTD.

Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020

PANDUIT LATIN AMERICA

Guadalajara, Mexico cs-la@panduit.com Phone: 52.33.3777.6000

Contact Customer Service by email: cs@panduit.com or by phone: 800.777.3300

Visit us at www.panduit.com For more information

Dimensions are in inches [Dimensions in brackets are in millimeters].

p e r f o r m a n c e i n f o r m a t i o n

Simplex Connector

Duplex Connector OptiCam® Termination Tool LC Lock-In Duplex Clip

Test Parameter Description Result

Qualification test suite (TIA/EIA-568-B.3 requirements)

Complete testing protocol per TIA/EIA-568-B.3 using TIA/EIA FOTPs that include mechanical, environ-mental and optical test sequences

Exceeds TIA/EIA-568-B.3 requirements

Connector intermatability Dimensional and material compliance to TIA/EIA standards

All connectors are FOCIS compatible with

TIA/EIA-604-10

Repeated mating 500 mate/unmate cycles Max. insertion loss: 0.75dB Min. return loss: 20dB

Exceeds TIA/EIA-568-B.3 test requirements:

<0.1dB additional insertion loss

Cable retention (straight pull):

900μm tight-buffered fiber

Jacketed cable

TIA/EIA-568-B.3 requirement:

0.5 lbs. load applied with <0.5dB increase in insertion loss after test

11.24 lbs. load applied with <0.5dB increase in insertion loss after test

Exceeds TIA/EIA-568-B.3 requirements:

1.0 lbs. avg. load applied with <0.2dB increase in insertion loss after test

11.24 lbs. load applied with <0.1dB increase in insertion loss after test*

*All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-FOTP-171.

s e l e c t i o n i n f o r m a t i o n Part Number Connector

Type Ferrule Material

Fiber Ferrule Finish

Backbone Color

Boot

Average Insertion Loss**

Return Loss

FLCSMCXAQY Simplex Zirconia Ceramic

10 GbE 50/125μm (laser optimized)

OM3/OM4

SPC Aqua Aqua 0.3dB >26dB

FLCDMCXAQY Duplex

FLCSMC5BLY Simplex Zirconia Ceramic 50/125μm OM2 SPC Black Black 0.3dB >20dB

FLCDMC5BLY Duplex

FLCSMC6BLY Simplex Zirconia Ceramic 62.5/125μm OM1 SPC Electric

Ivory Black 0.3dB >20dB

FLCDMC6BLY Duplex

FLCSSCBUY Simplex Zirconia Ceramic 9/125μm OS1/OS2 UPC Blue Blue 0.3dB >50dB

FLCDSCBUY Duplex

FLCSMC***Y FLCDMC***Y OCTT

(Patch cords available separately or in termination kits)

FLCCLIW-X

Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.

PHYSICAL INFRASTRUCTURE SYSTEMS

A.

System

Overview

B.

Copper

Systems

C.

Fiber Optic

Systems

D.

Power over Ethernet

E.

Zone

Cabling

F.

Wireless

G.

Outlets

H.

Media

Distribution

I.

Physical

Infrastructure Management

J.

Overhead & Underfloor

Routing

K.

Surface

Raceway

L.

Cabinets, Racks &

Cable

M.

Grounding &

Bonding

N.

Industrial

O.

Labeling &

Identification

P.

Cable

Accessories

Q.

Index

Opticom® Wall Mount Enclosures

• Holds Opticom ® Fiber Adapter Panels (FAPs)

• Rugged all metal construction for fiber protection and secure mounting

• Compact design allows installation in tight areas

• Separate doors for service side and user side with optional keyed locks for added security

• Include fiber optic cable routing kit (grommets, cable ties, spools, strain relief bracket and ID/caution labels) for various cable management solutions

FWME2

FWME4

FWME8

All product color is black.

*MTP is a registered trademark of US Conec Ltd.

Part Number Part Description

Std.

Pkg.

Qty.

Fiber Wall Mount Enclosures

FWME2 Holds up to two QuickNet™ Cassettes, FAP, or FMP panels.

Dimensions: 12.00"W x 10.18"H x 2.32"D (304.8mm x 258.6mm x 59.1mm)

FWME4 Holds up to four QuickNet™ Cassettes, FAP, or FMP panels.

Dimensions: 16.11"W x 12.25"H x 3.52"D (409.2mm x 311.0mm x 89.4mm)

FWME8 Holds up to eight QuickNet™ Cassettes, FAP, or FMP panels.

Dimensions: 16.11"W x 16.11"H x 5.00"D (409.2mm x 409.2mm x 127.0mm)

Fiber Accessories

FELS Fiber enclosure lock for service side. 1

FELU Fiber enclosure lock for user side. 1

LC Fiber Optic Adapters k e y f e a t u r e s a n d b e n e f i t s a p p l i c a t i o n s t e c h n i c a l i n f o r m a t i o n s p e c i f i c a t i o n s LC small form factor (SFF) fiber optic adapters with integrated panel retention clips are TIA/EIA-604 FOCIS-10 compatible. Each LC simplex adapter shall connect one LC connector pair in one module space.

Each LC duplex adapter shall connect two LC connector pairs in one module space. LC adapters and adapter modules shall include phosphor bronze split sleeves for multimode applications or zirconia ceramic split sleeves for singlemode applications.

Standards requirements: TIA/EIA-604 FOCIS-10 compatible; exceeds TIA/EIA-568-B.3 requirements

Split sleeve material: Phosphor bronze or zirconia ceramic (required for singlemode applications)

Insertion loss: .1dB average (multimode and singlemode); supports the performance of FOCIS-10 compliant connectors/patch cords

Return loss: Supports singlemode (>40dB for SPC and >55dB for UPC) and multimode (>20dB) connector polish performance

Panduit LC SFF Fiber Optic Adapters can be used with Mini-Com® Modules, Patch Panels, Faceplates and Surface Mount Boxes for a complete LC system solution. LC adapters provide a rugged solution for LANs, public networks, storage area networks and fiber-to-the-desk applications. The high-density design and 1.25mm ferrules double the port density (compared to SC connectors) to reduce space requirements on racks, enclosures, panels and faceplates. LC adapters can also be mounted in high-density applications within Opticom® QuickNet™ Pre-Terminated MTP* Cassettes and Fiber Enclosures, and Opticom®

Fiber Adapter Panels (FAPs) and Enclosures.

HDCRT Connector Removal Tool can be used to simplify removal of connectors in high-density applications.

Integrated panel No metal clips to become bent, damaged or lost; simplex adapter retention clips clips automatically adjust for FOCIS-10 compliant panel thickness variations for improved mounting

Superior weld strength Provides a more durable product under stress for improved reliability and increased life

LC duplex adapters fit Doubles the density in the same rack space; substitute simplex SCs SC simplex adapter openings with duplex LCs to increase connectivity 100%

Short flange design Improved modularity and higher density usage

Choice of phosphor bronze or Provides an adapter split sleeve material option to fit specific zirconia ceramic split sleeves network requirements

Adapters available in System flexibility; modules are interchangeable within Panduit ®

Mini-Com ® Modules Mini-Com® Outlets, Boxes and Patch Panels

Adapters available in patch Provides a complete LC system solution panels, fiber adapter panels (FAPs) and Opticom ® QuickNet ™

Pre-Terminated MTP* Cassettes

Modules available in Allows color-coding for network segregation multiple colors

*MTP is a registered trademark of US Conec Ltd.

LC Sr./Jr. Fiber Optic Adapters

Duplex MM: FADJLCEI-L Duplex 10Gig™: FADJLCAQ-L Simplex 10Gig™ (zirc.): FASJLCZAQ-L Duplex 10Gig™ (zirc.): FADJLCZAQ-L Simplex SM (zirc.): FASJLCZBU-L Duplex SM (zirc.): FADJLCZBU-L L = Bag of 50 adapters; 100 per carton.

Mini-Com ® LC Sr./Sr. Adapter Modules Duplex MM: CMDSLC** Duplex 10Gig™: CMDSAQLCBL Duplex 10Gig™ (zirc.): CMDSAQLCZBL Duplex SM (zirc.): CMDSLCZ**

Mini-Com ® LC Sr./Jr. Adapter Modules Duplex MM: CMDJLC** Duplex 10Gig™: CMDJAQLCBL Duplex 10Gig™ (zirc.): CMDJAQLCZBL Duplex SM (zirc.): CMDJLCZ**

Opticom® LC Fiber Adapter Panels 6 duplex MM: FAP6WEIDLC 6 duplex 10Gig™ (zirc.): FAP6WAQDLCZ 6 duplex SM (zirc.): FAP6WBUDLCZ 12 duplex MM: FAP12WEIDLC 12 simplex SM (zirc.): FAP12WBULCZ

Opticom® QuickNet™ Pre-Terminated MTP* Cassettes 6 LC to MTP* (12f): FC^-12-10 12 LC to 2 MTP* (24f): FC^-24-10

LC Simplex Fiber Optic Connectors Multimode: FLCSMEI Singlemode: FLCSSBU

LC Duplex Fiber Optic Connectors Multimode (1.6 – 2mm): FLCDMEI Singlemode (1.6 – 2mm): FLCDSBU Multimode (900µm): FLCDM900EI Singlemode (900µm): FLCDS900BU

Opti-Core ® Fiber Optic Patch Cords Duplex LC to LC: F^E10-10M‡ Simplex LC to LC: F^F10-10M‡ Simplex LC to pigtail: F^B10-NM‡

HD Connector Removal Tool For LC and SC HDCRT

**Substitute for module color:

EI = Electric Ivory BU = Blue IG = International Gray WH = White TG = Technical Gray BL = Black AW = Arctic White IW = Off White EW = European White

^Substitute for fiber type:

X (OM3/OM4 – 10Gig™ 50/125µm), 5 (OM2 – 50/125µm), 6 (OM1 – 62.5/125µm) or 9 (OS1 – 9/125µm).

‡Substitute for length in meters: 1, 2, 3, 5 or 10 for patch cords, and 1, 2 or 3 for pigtails; singlemode patch cords are also available in 12, 15, 25 or 30 meter lengths. Contact Customer Service for other available lengths.

LC Sr./Sr. Fiber Optic Adapters

Duplex MM: FADSLCEI-L Duplex 10Gig™: FADSLCAQ-L Simplex 10Gig™ (zirc.): FASSLCZAQ-L Duplex 10Gig™ (zirc.): FADSLCZAQ-L Simplex SM (zirc.): FASSLCZBU-L Duplex SM (zirc.): FADSLCZBU-L L = Bag of 50 adapters; 100 per carton.

Panduit LC Connector/Adapter connection• www.panduit .com

SPECIFICATION SHEET

LC Fiber Optic Adapters

©2009 Panduit Corp.

ALL RIGHTS RESERVED.

WW-FBSP14

9/2009

Dimensions are in inches [Dimensions in brackets are in millimeters].

For a copy of PANDUIT product warranties, log on to www.panduit.com/warranty

Contact Customer Service by email: cs@panduit.com or by phone: 800-777-3300 and reference FBSP14

Visit us at www.panduit.com For more information d e s i g n i n f o r m a t i o n LC Adapter Type Description Application Type

Sr./Sr.

(Senior/Senior)

Has a FOCIS-10 senior adapter interface (without keyway) at each end.

Both ends accept FOCIS-10 compatible senior LC connectors (non-keyed; spring loaded ferrules).

Typically used for patch panel and outlet applications, including behind the wall applications.

Sr./Jr.

(Senior/Junior)

Has a FOCIS-10 senior adapter interface (without keyway) at one end and a FOCIS-10 compatible junior adapter interface (with keyway) at the other end.

Both ends accept all FOCIS-10 compatible senior LC connectors (non-keyed; spring loaded ferrules).

Junior end also accepts FOCIS-10 compatible junior LC connectors (keyed; fixed ferrule/springless).

Shorter profile of junior end accommodates tighter applications behind the wall, allowing easier access to FOCIS-10 compatible junior (shorter) LC connectors terminated on 900µm buffered fiber.

Panduit ® Opticom® Fiber Adapter Panels and QuickNet™ Pre-Terminated Cassettes include Sr./Jr. Adapters.

LC Sr./Sr. Simplex Adapter (SM)

LC Sr./Jr. Simplex Adapter (SM)

Opticom ® LC Duplex Fiber Adapter Panel

Mini-Com ® LC Sr./Jr.

Adapter Module

LC Sr./Jr.

Duplex Adapter

.46 [11.6]

.27 [6.8]

.51 [12.9]

.46 [11.6] .37

[9.3] .37 [9.3]

.51 [12.9]

.71 [18.0]

.62 [15.8] 1.37

[34.8]

1.05 [26.6]

1.08 [27.4]

1.02 [25.8]

1.15 [29.1]

.27 [6.8]

HDCRT

Opticom ® QuickNet™

Cassettes HDCRT Connector

Removal Tool

LC Sr./Sr.

Duplex Adapter

Sr./Sr.

Part Number Adapter Type

Split Sleeve Material

Adapter

Module

Average Insertion Loss^

Return Loss^

^Panduit LC Connector/Adapter connection.

**For other colors, replace suffix EI or BU with EI (Electric Ivory), BU (Blue), IG (International Gray), WH (White), TG (Technical Gray), BL (Black), AW (Arctic White), IW (Off White) or EW (European White).

FADSLCEI-L Multimode Duplex Phosphor Bronze Electric Ivory N/A

.1dB

>20dB

>40dB

FADSLCAQ-L 10Gig™ Multimode Duplex Phosphor Bronze Aqua N/A

FASSLCZAQ-L 10Gig™ Multimode Simplex Zirconia Ceramic Aqua N/A

FADSLCZAQ-L 10Gig™ Multimode Duplex Zirconia Ceramic Aqua N/A

FASSLCZBU-L Singlemode Simplex Zirconia Ceramic Blue N/A

FADSLCZBU-L Singlemode Duplex Zirconia Ceramic Blue N/A

LC Adapter Modules

.1dB >20dB

>40dB

CMDSLCEI Multimode Duplex Phosphor Bronze Electric Ivory Various**

CMDSAQLCBL 10Gig™ Multimode Duplex Phosphor Bronze Aqua Black

Black

Various**

CMDSAQLCZBL 10Gig™ Multimode Duplex Zirconia Ceramic Aqua

CMDSLCZBU

Sr./Jr.

Part Number

FADJLCEI-L

FADJLCAQ-L

FASJLCZAQ-L

FADJLCZAQ-L

FASJLCZBU-L

FADJLCZBU-L

CMDJLCEI

CMDJAQLCBL

CMDJAQLCZBL

CMDJLCZBU Singlemode Duplex Zirconia Ceramic Blue

LC Adapters s e l e c t i o n i n f o r m a t i o n

3.91 [99.4]

WORLDWIDE SUBSIDIARIES AND SALES OFFICES

PANDUIT CANADA

Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300

PANDUIT EUROPE LTD.

London, UK cs-emea@panduit.com Phone: 44.20.8601.7200

PANDUIT JAPAN

Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000

PANDUIT SINGAPORE PTE. LTD.

Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575

PANDUIT AUSTRALIA PTY. LTD.

Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020

PANDUIT LATIN AMERICA

Jalisco, Mexico cs-la@panduit.com Phone: 52.33.3777.6000

DRAWING REV. DATE DRWN. APP. REMARKS

38601

38601 .16 8/22/13 BAL JB Removed Tape Seperator

Comtran Cable LLC 330A Turner Street South Attleboro, MA 02703-7714

(P) 508-399-7004

(F) 508-399-7360 www.ComtranCorp.com

Design Specification Category 6 Plenum UTP

Construction: Compliance:

* Conductors: 23 AWG Solid Bare Copper per ASTM B-3 * ETL Verified ANSI/TIA-568-C.2 Cat 6

* Insulation: Fluoropolymer * UL Subject 444 Communications Cables

* Pair Assembly: Color Coded Conductors twisted to varying lays * UL Listed type CMP

* Cable Assembly: 4 Pairs cabled to form a round core * NFPA 262 Plenum Flame Test (UL910)

* Jacket: Color Coded Plenum PVC * NEC Article 800

Nominal OD = .190” * c(UL) Type CMP

*Ripcord: Ripcord provided under jacket * ICEA S-102-700

(Increasing/Decreasing Footage Markers Provided) * California State Fire Marshal

* RoHS Compliant

Features: Common Applications:

* Superior 4 pair balance for increased margins * Gigabit Ethernet (1000Base-T)

* Low skew and Propagation delay * Multimedia & ISDN

* Small compact round design * High speed Voice/Data applications

* Extended Bandwidth (increased Headroom) * 1.2 Gbps Ethernet

* Excellent Cross Talk characteristics * Broadband Video

* Custom Print legends, Put-up’s and Special colors per request * Desktop Publishing

* Video Conferencing/Imaging

Category 6 Electricals (per ANSI/TIA 568-C.2)

(Information Subject to change without notice)

Part# Color

34277 Green

34481 Yellow

34932 Gray

35334 Red

35675 Violet

38600 Blue

38601 White

Char. Impedance Return Loss Attenuation NEXT PSNEXT ACRF PSACRF

Freq. (Ohms) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB/100m)

(MHz.) (+/-15) (Min) (Max) (Min) (Min) (Min) (Min)

1 100 20 2 74.3 72.3 67.8 64.8

4 100 23 3.8 65.3 63.3 55.7 52.7

8 100 24.5 5.3 60.8 58.8 49.7 46.7

10 100 25 6 59.3 57.3 47.8 44.8

16 100 25 7.6 56.3 54.3 43.7 40.7

20 100 25 8.5 54.8 52.8 41.7 38.7

25 100 24.3 9.5 53.3 51.3 39.8 36.8

31.25 100 23.6 10.7 51.9 49.9 37.9 34.9

62.5 100 21.5 15.4 47.4 45.4 31.8 28.8

100 100 20.1 19.8 44.3 42.3 27.8 24.8

125 100 19.4 22.4 42.9 40.9 25.8 22.8

155.52 100 18.8 25.2 41.4 39.4 23.9 20.9

175 100 18.4 26.9 40.7 38.7 22.9 19.9

200 100 18 29 39.8 37.8 21.7 18.7

250 100 17.3 32.8 38.3 36.3 19.8 16.8

Mutual Cap. = 14pf/ft DC Res.= 7.1 Ω/100m

Propagation Delay Skew: 45 ns/100m (max)

Operating Temperature: -10c to 75c

ACR (min) @ 100 MHz = 24.1dB/100m

ACR (min) @ 200 MHz = 10.0 dB/100m

Nominal Velocity of Propagation (NVP) = 70%

Hubbell’s Surface Mount Boxes are designed to facilitate today’s most demanding workstation outlet needs. The ISB1 and ISB2 are single and 2-port versions allowing for a wide variety of Hubbell data, audio/video and fiber connectivity.

The surface mount boxes are ideal for open office, compact surface mount environments, and retrofits to support data, voice, and multimedia applications. All surface mount boxes can be mounted with supplied surface mounting screws or double-sided adhesive tape.

www.hubbell-premise.com

FEATURES

Low-profile design
Accepts Hubbell HJ and HXJ jacks and audio/

video keystone connectors

Available in five color options
ADA compliant
Ability to mount to multiple surfaces:
Standard electrical boxes
Hubbell Raceway
RE-BOX®
CP enclosure
Rack rail
Desktops, walls, and modular furniture

STANDARDS

UL and cUL listed
ANSI/TIA/EIA-606A compliant

Surface Mounting

Accepts Standard Jacks, Fiber and AV Connections

ADA Compliant

RoHS Compliant

Flexibility Easy cover latches allow for simple moves, adds and changes

Safety Tamper resistant screw located behind the faceplate label field

Installation Ease Bases include tie-wrap anchor points at all cable entrances

APPLICATIONS

Open office environments
Compact surface mount environments
Retrofits to support data, voice, and multimedia applications

Surface Mount Boxes, 1- and 2-Port

POLYTRAK® Raceway Compatibility Chart

Series PP PB

ISB1 *

ISB2 *

*Use PB3REDA transition fitting.

SPECIFICATIONS

Provided with double-sided tape and mounting screws for easy installation

Constructed with a high impact resistant, flame retardant polymer

Base includes tie wrap anchors at rear cable entry point for 4" cable ties (included)

Surface box cover features easy-to-remove knockouts to accommodate Hubbell Raceway

ISB1OW

(loaded)

ISB2OW

(loaded)

HUBBELL PREMISE WIRING COPPER

HUBBELL PREMISE WIRING COPPER

DIMENSIONSORDERING INFORMATION

RELATED PRODUCT

ISB Surface Mount Boxes, 1- and 2-port Color 1-Port 2-Port

Almond ISB1AL ISB2AL

Black ISB1BK ISB2BK

Electric Ivory ISB1EI ISB2EI

Gray ISB1GY ISB2GY

Office White ISB1OW ISB2OW

White ISB1W ISB2W

Premise Wiring www.hubbell-premise.com

Hubbell Premise Wiring • Hubbell Incorporated (Delaware) • 23 Clara Drive • Suite 103 • Mystic, CT 06355 • Phone (800) 626-0005 • FAX (860) 535-8328 Printed in U.S.A. Specifications subject to change without notice.

® is a registered trademark of Hubbell Incorporated. PLDC012 03/12

2.38

0.55 1.30

0.18 0.42

(1.77)

1.05 1.08

0.22

0.68

0.36 0.36 0.58

1.77

0.43 0.18

2.38

1.36

0.39

2.30

0.24

1.82

0.67

0.24

0.42

0.68

0.22

1.081.05

0.37 0.58 0.370.580.39

HJ and HXJ Jacks Category 6, 6A and 5e

UOM Category 5e Category 6 Category 6A

1 per bag/carton of 25 HXJ5Exx* HXJ6xx* HJ6Axx**

25 per bag/carton of 1 HXJ5Exx25 HXJ6xx25 HJ6Axx25** xx = Color: AL (Almond), BK (Black), B (Blue), BN (Brown), EI (Electric Ivory), GL (Gold), GY (Gray), GN (Green), LA (Light Almond), OW (Office White), OR (Orange), P (Purple), R (Red), TI (Telco Ivory), W (White) and Y (Yellow).

Light Almond is the same color as Office White.

*Brown, Gold and Purple available as 25-pack only.

**Not available in Telco Ivory.

Patch Cords Category 6, 6A and 5e

UOM Category 5e Category 6 Category 6A

1 patch cord HC5Exxyy HC6xxyy HC6Axxyy xx = Color: BK (Black), B (Blue), GY (Gray), GN (Green), OR (Orange), P (Purple), R (Red), W (White) and Y (Yellow). See color chart in technical section.

yy = Standard Length: 01 (1'), 03 (3'), 05 (5'), 07 (7'), 10 (10'), 15 (15'), 20 (20').

MTO lengths: 25', 30', 35', 40', 45', 50', 55', 60', 75', 80', 85', 90', 95', and 100'.

1-Port

2-Port

VELCRO® is a registered trademarks of Velcro Industries B.V.

C24206RHPL

MAC DILL BASE

EMERGENCY RESPONSE

JUNCTION BOX FOR

HOUSING BTXWAC

PADLOCK

DEVICE

James

James

Line

Robert A. Rolley, P.E.

MacDill Air Force Base

EMERGENCY RESPONSE NOTIFICATION SYSTEM

(NVZR 16-0065)

Prepared for:

R.M. Williams Construction

504 S. Moddy Ave.

Tampa, Florida 33609-3342

By:

7759 West Waters Ave.

Tampa, Florida 33615

SUBSTITUTION REQUEST

EST – HYPERSPIKE SPEAKER ARRAYS

Resubmitted April 11, 2017

Table of Contents

TAB 1

TAB 2

EST Hyperspike “HPSA” Cutsheets .............................................................................................. 1 - 1

“Crown” Amplifier Cutsheets ...................................................................................................... 1 - 7

“Crown” Amplifier Specifications............................................................................................... 1 – 9

Edwards ANS25MD*2 Audio Message Storage Unit Cutsheets ................................................ 1 - 10

Interface Specification – Edwards Hyperspike Interface with Monaco BT-XWAC..................... 1 - 18

Mounting Detail – Pole Mount Bracket, ECC – UTC ................................................................... 1 - 22

Mounting Detail – HS-Series Emitter Pole Mount ..................................................................... 1 - 24

American Signal E-Class HPSA Cutsheets ...................................................................................... 2 - 1

TAB 3

EST Hyperspike vs American Signal Comparison .......................................................................... 3 - 1

TAB 4

TAB 5

Sound Pressure Level (SPL) Mapping ............................................................................................ 4 - 1

Drawing ES101 – Giant Voice Tower Locations......................................................................... ES101

Drawing ES102 – Proposed Sound Level dBA Map.................................................................... ES102

Drawing ES103 – Proposed Intelligibility Level STI Map............................................................ ES103

EST Hyperspike “HPSA” -Technical Guide ................................................................................... 5 - i

TAB 1

EST Hyperspike “HPSA” Cutsheets ................................................Pages 1 - 6 "Crown" Amplifier Cutsheets ............................................................Pages 7 - 8 "Crown" Amplifier Specifications ......................................................Page 9 Edwards ANS25MD*2 Audio Message Storage Unit Cutsheets......Pages 10 - 17 Interface Specification - Edwards Hyperspike Interface with Monaco BT-XWAC...............................................................Pages 18 - 21 Mounting Detail – Pole Mount Bracket, ECC – UTC.........................Pages 22 - 23 Mounting Detail – HS-Series Emitter Pole Mount ............................Pages 24 - 25

D A T A S H E E T 85001-0637

11-08-13

EST Catalog u EST3-Sixty -- Mass Notification

Lightweight High Power Speaker Arrays HS Series

Overview EST brand HS Series High Power Speaker Arrays (HPSA) em-ploy exclusive HyperSpike® technology to deliver lightweight and acoustically sophisticated solutions for for outdoor Emergency Communication Systems/Mass Notification Systems/Life Safety Systems (ECS/MNS/LSS) installations. These rugged outdoor-rated units are among the industry's smallest in physical size, yet they reproduce some of the clearest (up to 0.91 STI, source-dependant) and loudest (up to 138 dBA-fast @ 1m) audio signals available. Loudspeaker heads are as small as 13.2" (33.52 cm) in diameter and 25.25” (64.13 cm) in height. A single panel unit weighs as little as 16 lb (7.3 kg).

HS Series loudspeakers are available in a number of different con-figurations, from one panel configurations that provide a relatively narrow sound dispersion, to five-panel configurations with full 360° sound projection.

The unique design of HS Series loudspeakers allow for a 100 percent up-time duty cycle — when powered from an AC source, they can be powered and ready to perform 24/7. This makes them ideally suited for daily activation, as well as emergency use.

HS Series HPSAs can he permanently installed, or can be con-figured for portable use. Units come standard with an internal inverter/charger system that can operate the HPSA from the 24 VDC battery compliment.

Each HS Series HPSA loudspeaker has a remotely-mounted Electronics Control Cabinet (ECC) that can be installed indoors or outdoors. These house the audio power amplifiers as well as control and power equipment. The lockable reinforced fiberglass cabinets are rated NEMA 3, 3R, 3S, 4, 4X, 12, 12K and 13. They come ready to interface with the EST3-Sixty Emergency Commu-nication Platform.

Standard Features

• Intelligible audio performance (up to 0.91 STI)

• 24/7/365 duty cycle

• 360, 230, 185 and 120 degree dispersion pattern options

• 320 to 6400 watt configurations

• Easy installation – mounts to standard 2-inch diameter mast

• Lightweight loudspeaker heads – as low as 16 pounds (7.3 kg)

• Rugged outdoor construction

• Reliable and supervised interfaces to the EST3-Sixty platform

• Includes a 8 ft (2.44 m) flexible weathertight wiring conduit

1 - 1

Application Any outdoor facilities, such as:

• Universities, Colleges & High Schools

• Health care campuses

• Quads

• Parking lots

• Military bases

• Force protection

• Large ships

• Piers

• Docks

• Industrial complexes

• Refineries

• Power plants

• Air fields

• Stadiums

• Golf Courses

• Camp Grounds

• Amusement parks

• Open mines

• Weather warning systems

• Flood warning systems

• Civil defense

Installation For optimal performance and safety when installing in permanent locations, High Power Speaker Arrays (HPSAs) loudspeakers should be mounted 35 to 55 feet (10.7 to 16.8 m) above grade on a pole, building or other structure. For portable or vehicle-mounted applications, the loudspeaker head should be at least 20 feet (6.1 m) above grade and away from people. For all installations, it is also key to have clear, open space around the speaker head.

HPSA output is best via line-of-sight.

The factory assembled and tested Electronics Control Cabinets (ECCs) contain the HPSA interface terminals, transient protectors, and components to support easy, clean, and supervised connec-tion to the EST3-Sixty platform. This makes for simple and intuitive control of the units from a single control point or multiple locations.

The ECCs contain the power amplifier(s), digital signal processor, and power inverter system. Batteries are maintained in a Ready State by a temperature-compensated charging system.

The ECCs can be mounted inside or outside. Mounting options include pole, flange (wall), or pedestal. Heaters and ventilation units can also be ordered when required. When outdoor mounting, ECC and battery cabinets can be mounted below the loudspeaker head for easy access, but high enough to prevent vandalism. The ECC can hold one or two replaceable power amplifiers. Cabinets are equipped with tamper switches.

Internal displays and diagnostic LEDs simplify maintenance. HPSA status is also transmitted to the EST3-Sixty platform. A GFCI-pro-tected convenience outlet is provided with ECCs to aid in servic-ing. All ECC power is protected with circuit breakers. Exterior wiring to and from the ECC is protected by transient protectors.

Typically, the HS Series HPSA provides the EST3-Sixty platform with the following signals:

• Activation Confirmation

• Incoming AC failure

• Inverted AC failure

• Audio failure

• DC failure

• Door tamper

Units come standard with a one year warranty. An optional second year of additional coverage may be purchased at the time of the initial order. Warranties exclude batteries, which carry a 90-day warranty.

US Military Specifications Loudspeaker Head

Random vibration MIL-STD 810F, Method 514.4 Shipboard vibration MIL-STD 167-1A Shipboard shock MIL-STD-910D, Class 1 SRS shock MIL-STD-810F, Method 516.5 Rain MIL-STD-810F, Method 506.4 Operating Humidity MIL-STD-810F, Method 507.4 Salt fog MIL-STD-810F, Method 509.4

1 - 2

Typical Deployment

Specifications Loudspeakers

Speaker Panels Sound Dispersion 1600 Class 3200 Class 6400 Class

Output

5 Panel Array 360° 1600 Watts 3200 Watts 6400 Watts 3 Panel Array 230° 960 Watts 1920 Watts 3840 Watts 2 Panel Array 185° 640 Watts 1280 Watts 2560 Watts 1 Panel Array 120° 320 Watts 640 Watts 1280 Watts

Weight

5 Panel Array 360° 48 lb. (21.77 kg) 96 lb (43.55 kg) 192 lb (87.09 kg) 3 Panel Array 230° 31 lb (14.06 kg) 62 lb (28.12 kg) 124 lb (56.25 kg) 2 Panel Array 185° 24 lb (10.89 kg) 48 lb (21.77 kg) 96 lb (43.55 kg) 1 Panel Array 120° 16 lb (7.26 kg) 32 lb (14.52 kg) 64 lb (29.03 kg)

Dimensions Each Diameter 13.2" (33.52 cm) 13.2" (33.52 cm) 13.2" (33.52 cm) Each Height 25.25" (64.13 cm) 40.50" (102.87 cm) 81" (205.74 cm)

Environmental Operating temperature: -40 °F to 167 °F (-40 °C to 75 °C); Humidity: 0% to 95% (non-condensing).

Electronics Control Cabinet

Dimensions 70" x 30" x 12"

177.8 x 76.2 x 30.5 cm 70" x 30" x 12"

177.8 x 76.2 x 30.5 cm 70" x 60" x 12"

177.8 x 152.4 x 30.5 cm Weight (without batteries) 242 lb (109.8 kg) 248 lb (112.5 kg) 496 lb (225.0 kg)

Sound Dispersion Patterns

5-Panel Array 360° Sound Dispersion

Structure

3-Panel Array 230° Sound Dispersion

S tr uc tu re

2-Panel Array 185° Sound Dispersion

Structure

1-Panel Array 120° Sound Dispersion

NEMA 4X

Enclosures

AC Mains

Can be mounted indoors or outdoors

HS Series Speaker Head

Outdoor use only

Audio from EST3-Sixty

Control from EST3-Sixty/ FireWorks

Connection Media/Method

Electronic Control Cabinet

(ECC)

Battery Cabinet

(24 VDC)

1 - 3

High Power Speaker Array Assemblies HPSA Assemblies are AC powered with DC backup. They come with a lockable NEMA 4 Electronics Control Cabinet (ECC) that holds the amplifier and battery charger, and a lockable NEMA 4 battery enclosure. Enclosures are equipped with tamper switches. Loudspeak-ers come pre-assembled with an eight foot (2.4 meter) ¾-inch liquid-tite flexible conduit whip and wire leads. Batteries and battery enclosures are ordered separately.

High Power Speaker Array Assemblies

Model Number Output Sound Dispersion Active Panels

Speaker Head ColorWith 230V/50Hz inverter/charger With 230V/50Hz inverter/charger

1600 Watt Class

MN-HS16T5P MN-HS16T5P-E 1600 Watts 360° 5 of 5

Tan MN-HS16T3P MN-HS16T3P-E 960 Watts 230° 3 of 5 MN-HS16T2P MN-HS16T2P-E 640 Watts 185° 2 of 5 MN-HS16T1P MN-HS16T1P-E 320 Watts 120° 1 of 5 MN-HS16G5P MN-HS16G5P-E 1600 Watts 360° 5 of 5

Gray MN-HS16G3P MN-HS16G3P-E 960 Watts 230° 3 of 5 MN-HS16G2P MN-HS16G2P-E 640 Watts 185° 2 of 5 MN-HS16G1P MN-HS16G1P-E 320 Watts 120° 1 of 5

3200 Watt Class

MN-HS32T5P MN-HS32T5P-E 3200 Watts 360° 5 of 5

MN-HS32T3P MN-HS32T3P-E 1920 Watts 230° 3 of 5 MN-HS32T2P MN-HS32T2P-E 1280 Watts 185° 2 of 5 MN-HS32T1P MN-HS32T1P-E 640 Watts 120° 1 of 5 MN-HS32G5P MN-HS32G5P-E 3200 Watts 360° 5 of 5

MN-HS32G3P MN-HS32G3P-E 1920 Watts 230° 3 of 5 MN-HS32G2P MN-HS32G2P-E 1280 Watts 185° 2 of 5 MN-HS32G1P MN-HS32G1P-E 640 Watts 120° 1 of 5

6400 Watt Class

MN-HS64T5P MN-HS64T5P-E 6400 Watts 360° 5 of 5

MN-HS64T3P MN-HS64T3P-E 3840 Watts 230° 3 of 5 MN-HS64T2P MN-HS64T2P-E 1280 Watts 185° 2 of 5 MN-HS64T1P MN-HS64T1P-E 640 Watts 120° 1 of 5 MN-HS64G5P MN-HS64G5P-E 6400 Watts 360° 5 of 5

MN-HS64G3P MN-HS64G3P-E 3840 Watts 230° 3 of 5 MN-HS64G2P MN-HS64G2P-E 1280 Watts 185° 2 of 5 MN-HS64G1P MN-HS64G1P-E 640 Watts 120° 1 of 5

Protective Covers MN-HS16GPC Gray HS Series 1600 Watt class optional protective cover.

MN-HS32GPC Gray HS Series 3200 Watt class optional protective cover MN-HS64GPC Gray HS Series 6400 Watt class optional protective cover MN-HS16TPC Tan HS Series 1600 Watt class optional protective cover.

MN-HS32TPC Tan HS Series 3200 Watt class optional protective cover MN-HS64TPC Tan HS Series 6400 Watt class optional protective cover

Warranty Programs MN-HS16EXWARR2 HS Series 1600 Watt class extended warranty - 2 years total. Must be ordered when HPSA is ordered.

MN-HS32EXWARR2 HS Series 3200 Watt class extended warranty - 2 years total. Must be ordered when HPSA is ordered.

MN-HS64EXWARR2 HS Series 6400 Watt class extended warranty - 2 years total. Must be ordered when HPSA is ordered.

Batteries and Solar Charging MN-HSBATT140 HS Series ECC Standard Battery set. 140 AH SLA. 2 batteries required for each ECC. Replace in pairs.

MN-HSBHK1X

HS Series Battery compliment heating blankets (set of 2) for use with MN-HSBX1 Extended Battery Enclosure. 120 VAC.

Requires MN-HSECCH1.

MN-HSBHK1S HS Series Battery compliment heating blankets (set of 2). 120 VAC. Requires MN-HSECCH1. Two used for MN-HS64 Series.

MN-HSBX1

HS Series ECC Battery Extension enclosure (without batteries). Includes tamper switch, battery shelf and cabling. Can be mounted to the side or below the ECC primary battery enclosure.

Accessories

1 - 4

Amplifiers

MN-HSECC1

MN-HS16 Class lockable NEMA 4 amplifier, 110V/60Hz. inverter/battery charger and electronics enclosure, lockable NEMA 4 battery enclosure (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup. Batteries and accessories are ordered separately.

MN-HSECC2

MN-HS32 Class lockable NEMA 4 amplifier, 110V/60Hz. inverter/battery charger and electronics enclosure, lockable NEMA 4 battery enclosure (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup. Batteries

MN-HSECC4

MN-HS64 Class lockable NEMA 4 amplifier, 110V/60Hz. inverter/battery charger and electronics enclosures, lockable NEMA 4 battery enclosures (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup.

Batteries and accessories are ordered separately.

MN-HSECC1-E

MN-HS16 Class lockable NEMA 4 amplifier, 230V/50Hz. inverter/battery charger and electronics enclosure, lockable NEMA 4 battery enclosure (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup. Batteries

MN-HSECC2-E

MN-HS32 Class lockable NEMA 4 amplifier, 320V/50Hz. inverter/battery charger and electronics enclosure, lockable NEMA 4 battery enclosure (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup. Batteries

MN-HSECC4-E

MN-HS64 Class lockable NEMA 4 amplifier, 230V/50Hz. inverter/battery charger and electronics enclosures, lockable NEMA 4 battery enclosures (w/o batteries). Enclosures equipped with tamper switches. AC powered amplifier with DC backup.

Batteries and accessories are ordered separately.

Heating and Ventilation MN-HSECCFAN1 HS Series ECC Top-mount ventilation fan system with side louvers. 115 VAC. Changes ECC rating to NEMA 3R MN-HSECCFAN1-E HS Series ECC Top-mount ventilation fan system with side louvers. 230 VAC. Changes ECC rating to NEMA 3R

MN-HSECCH1

HS Series ECC Cabinet heater system kit (120 VAC). Provides terminals for battery heater blanket kits. One used for MN-HS16 & MN-HS32 Series. Two used for MN-HS64 Series.

MN-HSECCH1-E

HS Series ECC Cabinet heater system kit (230 VAC). Provides terminals for battery heater blanket kits. One used for MN-HS16 & MN-HS32 Series. Two used for MN-HS64 Series.

MN-HSECCPED1

HS Series ECC Housekeeping Pedestal Mount Kit (4"). Used when wall-mounting MN-HS16 or MN-HS32 Series ECC. 2 required if wall-mounting MN-HS64 Series ECCs.

Audio Sofware MN-AUDSOF1 HS Series audio optimization software package

Modeling Services

MN-HSEMD12

HS Series EASE modeling exterior direct/reflected energy. Up to (12) 3D buildings overlaid on Google earth map or provided PDF/CAD site topology drawing. Modeling based on 125-2Khz band and provide medium resolution graphics with 3dB steps in propagation for up to (6) acoustic device/array locations onto chloropleth map. Scale limit of this offer is for 4 million square feet venue.

MN-HSEMDNB

HS Series EASE modeling exterior direct energy only (no 3D buildings) overlaid on Google earth map or on provided PDF/CAD site topology drawing. Modeling based on 125-2Khz band and provide medium resolution graphics with 3dB steps in propagation or up to (4) acoustic device/array locations onto chloropleth map. Scale limit of this service is in 2 million square feet increments.

MNHSEMDQ

HS Series Ease modeling exterior direct/reflected energy. Over 12 3D buildings overlaid on Google earth map or provided PDF/CAD site topology drawing. Modeling based on 125-2Khz band and provide medium resolution graphics with 3dB steps in propagation for system required acoustic device/array locations onto chloropleth map. Contact Edwards Customer Service for quote.

MN-HSEMN12

HS Series EASE modeling interior direct/reflected energy. Up to (12) interior 3D substructures overlaid on provided PDF/CAD plan view drawing. Modeling based on 125-2Khz band and provide medium resolution graphics with 3dB steps in propagation for up to (10) acoustic device/array locations onto chloropleth map. Scale limit of this offer is for 250,000 square foot venue.

MN-HSEMN24

HS Series EASE modeling interior direct/reflected energy. Up to (24) interior 3D substructures overlaid on provided PDF/CAD plan view drawing. Modeling based on 125-2Khz band and provide medium resolution graphics with 3dB steps in propagation for up to (16) acoustic device/array locations onto chloropleth map. Scale limit of this offer is for 500,000 square foot venue.

MN-HSEMNQ

HS Series EASE modeling interior direct/reflected energy. Over 24 interior 3D substructures overlaid on provided PDF/CAD plan view drawing.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .