Attachment_3_Past_Performance_Summary_Sheet_(PPSS).pdf

PDF 16 KB Posted

Attached to
Base Operations Support Services, Avon Park AFR, Florida Federal contract opportunity
Solicitation number
FA4814-16-R-0004
Issued by
Department of the Air Force Air Mobility Command

About this file

Attachment Past Performance Summary Sheet

View the file

Other files for this federal contract opportunity

Other files attached to Base Operations Support Services, Avon Park AFR, Florida, newest first.
File Type Posted
RFI_Response_Sheet.pdf PDF
2_Appendix_A-Workload.pdf PDF
FA4814-16-R-0004-0003.pdf PDF
9_AF_Real_Property_Report_7115_ASPR.pdf PDF
1_PWS_30_March_2016.pdf PDF
8_AF_Real_Property_Report_7115_ASPQ.pdf PDF
3_Appendix_A-5_Target_Maintenance_Historical_Data.pdf PDF
4_Appendix_D_-_Facilities_Systems_Equipment.pdf PDF
7_Pesticide_Product_Summary.pdf PDF
6_Int_Pest_Management_Plan.pdf PDF
5_EESOH-MIS.pdf PDF
FA4814-16-R-0004-0002.pdf PDF
Sign_In_Sheet.pdf PDF
Avon_Park_Request_for_Information.docx DOCX document
FA4814-16-R-0004-0001.pdf PDF
Attachment_1_PPQ.pdf PDF
Attachment_2_PPI_Tool_Instructions.pdf PDF
Appendix_I_-_Minimum_Essential_Level_Vehicles.pdf PDF
Appendix_F_-_Support_Agreements _MOAs_and_Contracts.pdf PDF
Appendix_C_-_GOVERNMENT_FURNISHED_PROPERTY.pdf PDF
FA4814-16-R-0004.pdf PDF
Appendix_H_-_ABBREVIATIONS_and_ACRONYMS.pdf PDF
1_PWS_BOS_Services.pdf PDF
3_Service_Contract_Act_Wage_Determination.pdf PDF
2_QASP_BOS_Avon_Park.pdf PDF
Appendix_D_-_Facilities_Systems_Equip_for_Ops_Maint_Eng.pdf PDF
4_Davis_Bacon_Wage_Determination.pdf PDF
Appendix_G_-_Contractor_Employee_Certifications.pdf PDF
Appendix_J_-_Forms _Reports _Submittals _and_Technical_Letters.pdf PDF
Appendix_E_-_Applicable_Publications.pdf PDF
Appendix_B_-_Maps_and_Site_Plans.pdf PDF
Appendix_A_-_Workload.pdf PDF
DRAFT Appendix D - Facilities Systems Equip for Ops Maint Eng.pdf PDF
DRAFT Appendix B - Maps and Site Plans.pdf PDF
DRAFT Appendix G - Contractor Employee Certifications.pdf PDF
DRAFT Appendix E - Applicable Publications_Updated.pdf PDF
DRAFT Appendix A - Workload.pdf PDF
DRAFT Appendix H - ABBREVIATIONS and ACRONYMS.pdf PDF
DRAFT Performance Work Statement.pdf PDF
DRAFT Appendix J - Forms Reports Submittals and Technical Letters.pdf PDF
DRAFT Appendix C - GOVERNMENT FURNISHED PROPERTY.pdf PDF
https //www.fbo.gov/utils/view id 4062ba4be1dfcf0903f51bcf7b0ec97e —
DRAFT Appendix I - Minimum Essential Level Vehicles.pdf PDF
DRAFT Appendix F - Support Agreements MOAs and Contracts.pdf PDF
Show all 44

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 3, Past Performance Summary Sheet (PPSS)

1. Contractor:

2. Applicable Solicitation Subfactor (environmental, O&M, etc.,):

3. PPSS # ( ):

4. Past Performance Requirement:

5. Past Performance Location:

6. Start Date:

7. Completion Date:

8. Client Organization:

9. Facility Owner Organization:

a. Facility Owner Point of Contact:

b. Facility Owner Phone Number:

c. Facility Owner email Address:

10. Acted as Prime Contractor? (Yes/No)

11. Past Performance Description (scope, manpower, equipment, management)

Attachment 3, Past Performance Summary Sheet (PPSS) (SAMPLE)

1. Contractor: Gemini LLC

2. Applicable Solicitation Subfactor (environmental, O&M, etc.,): Subfactor 2 O&M

3. PPSS # (F high voltage distribution):

A. Past Performance Requirement: 2 years of experience within the last 5 years of operations, maintenance, and minor repair of a high voltage electrical distribution system rate at over 5 megawatts. This will include a substation, overhead distribution, underground distribution, switching, transformers, and lighting.

4. Past Performance Location: Keflavik Naval Air station

5. Start Date: Sept 2011

6. Completion Date: Aug 2014

7. Client Organization: 57 FIS

a. Point of Contact: Lt CMDR John Doe

b. Facility Owner Phone Number: 01-327-988-0897

c. Facility Owner email Address: Doe.john.5@us.navy.mil

8. Acted as Prime Contractor? (Yes/No): Yes

9. Past Perfromance Description (scope, manpower, equipment, management):

Through a NAVFAC $1.8M annual contract we provided all operations, maintenance, and repair for a 7.5 megawatt diesel power plant and 13.8KV power distribution system. Components included: substation, switch gear, 34 transformers, over 4 miles of overhead distribution, 1.2 miles of underground distribution, and street lights covering 2.3 miles of roadway. Our 13 man contract team included generator operators and electricians qualified for both high and low voltage system maintenance and repairs. We employed two high reach trucks and provided all vehicles, equipment, materials and parts to keep the system operational, provide new services and disconnect old services no longer needed. System achieved a

99.99% reliability rate with only one major outage in the duration of our 3 year contract.