About this file

This document appears to be a government file related to a federal contract opportunity. The key details are:

The federal contract opportunity is for the demolition and abatement of multiple buildings at Shaw Air Force Base, including the Base Theatre, Aerospace Physiology, Maintenance Hangar, Palmetto Heights Gate House, Locomotive Barn, and Picnic Shelter. The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for the demolition and abatement.

The solicitation number is FA480324R0040 and the opportunity is being issued by the Department of the Air Force, Air Combat Command. No further details are provided regarding response dates, award dates, pricing terms, set asides, incumbents, or other salient information.

View the file

Other files

File Type Posted
Version 2 - Site Visit sign in - Project Multi-Building Demo.pdf PDF
B202 2024-08-26.pdf PDF
Solicitation Amendment - FA480324R00400006.pdf PDF
B1724 2024-12-11.pdf PDF
B115 2024-08-26.pdf PDF
Base Map.pdf PDF
Version 2 -Questions and Answers.pdf PDF
01 SOW VLSB 23-0010 Demo Theater and Others 2024-12-11.pdf PDF
Version 1 - Questions and Answers - 26 Aug 24.pdf PDF
Solicitation Amendment FA480324R00400006 SF 30.pdf PDF
Version 1 - Site Visit - 7 Aug 24.pdf PDF
B1413 Theater Multiple Asbuilts.pdf PDF
B396 Asbuilts.pdf PDF
B1724.pdf PDF
B1047 Asbuilts addition 94.pdf PDF
B5237 Slab and Sign.pdf PDF
Wage determination Rev 23.pdf PDF
Solicitation Amendment - FA480324R00400005.pdf PDF
Version 1 - Questions and Answers - 26 Aug 24.docx DOCX document
B1908HWST.pdf PDF
B1047 Asbuilts addition 71.pdf PDF
01 SOW VLSB 23-0010 Demo Theater and Others 2024-11-05.pdf PDF
Solicitation Amendment FA480324R00400005 SF 30.pdf PDF
B212 Pavilion.pdf PDF
Solicitation Amendment FA480324R00400004 SF 30.pdf PDF
Solicitation Amendment - FA480324R00400004.pdf PDF
Solicitation Amendment FA480324R00400003 SF 30.pdf PDF
Solicitation Amendment - FA480324R00400003.pdf PDF
Building 202.pdf PDF
_Building 115 AsBuilts.pdf PDF
01 SOW 2024-08-26.docx DOCX document
B1047 2024-08-26.pdf PDF
Questions and Answers CE.docx DOCX document
Site visit sign in sheet.pdf PDF
Solicitation Amendment FA480324R00400002 SF 30.pdf PDF
Solicitation Amendment - FA480324R00400002.pdf PDF
Shaw AFB Contractor Request Template (2024) (WORK PURPOSES).docx DOCX document
Site visit SIGNED.pdf PDF
Solicitation Amendment FA480324R00400001 SF 30.pdf PDF
B1047 AsBuilts 1of3.pdf PDF
Building 202.pdf PDF
B1102 2024-07-01.pdf PDF
Wage Determination.pdf PDF
Solicitation - FA480324R0040.pdf PDF
B5004 2024-07-12.pdf PDF
Asbestos Survey 01047.pdf PDF
B1047 Asbuilts addition 3of3.pdf PDF
Asbestos Survey - BLDG 1413 1991 R.pdf PDF
Building 5004.pdf PDF
01 SOW VLSB 23-0010 Demo Theater and Others 2024-08-01.docx DOCX document
Show 40 more

Latest 50 of 55 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Viewer Map

Communication Antenna Communication Access Point Communication Amplifier Communication Attenuator Communication Device Communication Ground Point Communication Terminal Communication Terminator Communication Speaker Communication Splice

Abandoned Communication Lines Abandoned Proposed Abandoned/Removed Removed Out of Service

Segmented Communication Cable Other/TBD Proposed/Temporary Under Repair/Construction In Service

Communication Service Loop Other/TBD Proposed/Temporary Under Repair/Construction In Service Electrical Cathodic Protection Anode Electrical Cathodic Protection Bond Junction Electrical Cathodic Protection Rectifier Electrical Cathodic ProtectionTest Point Electrical Cathodic Protection Bond Wire Electrical Cathodic Protection Rectifier Cable

Electrical Access Point Manhole Handhole Junction Box Pull Box Vault Electrical Dyn Protective Device

Electrical Exterior Light Apron Light Parking Lot Light Recreation Field Light Security Light Street Light Traffic Light Electrical Generator Electrical Meter Electrical Structure Support Electrical Substation Electrical Surface Structure

Electrical Switch Primary Meter Other Electrical Transformer

Electrical Conduit System Proposed/Temporary Under Repair/Construction In Service

Electrical Counterpoise System Proposed/Temporary Under Repair/Construction In Service

Abandoned Electrical Overhead Primary Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Electrical Overhead Secondary Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Electrical Underground Primary Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Electrical Underground Secondary Abandoned Proposed Abandoned/Removed Removed Out of Service

Electrical Guy Wire Proposed/Temporary Under Repair/Construction In Service

Electrical Overhead Primary Proposed/Temporary Under Repair/Construction In Service

Electrical Overhead Secondary Proposed/Temporary Under Repair/Construction In Service

Electrical Underground Primary Proposed/Temporary Under Repair/Construction In Service

Electrical Underground Secondary Proposed/Temporary Under Repair/Construction In Service Electrical Outage and Repair Fuel Cathodic Protection Anode Fuel Cathodic Protection Bond Junction Fuel Cathodic Protection Rectifier Fuel Cathodic ProtectionTest Point Fuel Cathodic Protection Bond Wire Fuel Cathodic Protection Rectifier Cable Fuel Air Eliminator Fuel Control Valve Fuel Filter Strainer Fuel Fitting

Fuel Hydrant Airport Hydrant Building Hydrant Dry Barrel Freeze Proof Fuel Hydrant Other/TBD Wash Rack Hydrant Water Hydrant Wet Barrel Yard Hydrant Fuel Meter Fuel Oil Water Seperator Fuel Pump Fuel Pump Station Fuel Pump Station Area

Abandoned Fuel Installation Pipeline Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Fuel Line Defueling Abandoned Proposed Abandoned/Removed Removed Out of Service

Fuel Installation Pipeline Proposed/Temporary Under Repair/Construction In Service

Fuel Line Defueling Proposed/Temporary Under Repair/Construction In Service Fuel Outage and Repair Natural Gas Cathodic Protection Anode Natural Gas Cathodic Protection Bond Junction Natural Gas Cathodic Protection Rectifier Natural Gas Cathodic Protection Test Point Natural Gas Cathodic Protection Bond Wire Natural Gas Cathodic Protection Rectifier Cable Natural Gas Control Valve Natural Gas Drip Pot

Natural Gas Fitting Other Short Stop Three Way Tee Natural Gas Meter Natural Gas Regulator

Abandoned Natural Gas Distribution Line Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Natural Gas Service Line Abandoned Proposed Abandoned/Removed Removed Out of Service

Natural Gas Distribution Line Proposed/Temporary Under Repair/Construction In Service

Natural Gas Service Line Proposed/Temporary Under Repair/Construction In Service Natural Gas Outage and Repair Sewer Cathodic Protection Anode Sewer Cathodic Protection Bond Junction Sewer Cathodic Protection Rectifier Sewer Cathodic Protection Test Point Sewer Cathodic Protection Bond Wire Sewer Cathodic Protection Rectifier Cable Sewer Clean Out Sewer Fitting Sewer Grease Trap Sewer Manhole Sewer Oil Water Seperator Sewer Pump Sewer Pump Station Sewer Septic Tank Sewer Treatment Plant

Abandoned Sewer Gravity Main Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Sewer Gravity Service Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Sewer Pressurized Main Abandoned Proposed Abandoned/Removed Removed Out of Service

Sewer Gravity Main Proposed/Temporary Under Repair/ Construction In Service

Sewer Gravity Service Proposed/Temporary Under Repair/Construction In Service

Sewer Pressurized Main Proposed/Temporary Under Repair/Construction In Service Sewer Septic Tank Area Sewer Treatment Plant Area Stormwater Control Valve Stormwater Discharge Stormwater Erosion Control Stormwater Inlet Stormwater Manhole Stormwater Pump

Abandoned Stormwater Culvert Line Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Stormwater Gravity Line Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Stormwater Open Drainage Line Abandoned Proposed Abandoned/Removed Removed Out of Service

Stormwater Culvert Line Proposed/Temporary Under Repair/ Construction In Service

Stormwater Gravity Line Proposed/Temporary Under Repair/Construction In Service

Stormwater Open Drainage Line Proposed/Temporary Under Repair/Construction In Service Stormwater Storage Reservoir Thermal Cathodic Protection Anode Thermal Cathodic Protection Bond Junction Thermal Cathodic Protection Rectifier Thermal Cathodic Protection Test Point Thermal Cathodic Protection Bond Wire Thermal Cathodic Protection Rectifier Cable Thermal Control Valve Thermal Fitting Thermal Junction Thermal Pump Thermal Pump Station Area Thermal Regulator

Abandoned Thermal Chilled Water Return Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Thermal Chilled Water Supply Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Thermal Conventional High Temp Return Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Thermal Conventional High Temp Supply Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Thermal Conventional Return Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Thermal Conventional Supply Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Thermal Steam Trap Return Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Thermal Steam Trap Supply Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Thermal Condensing Return Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Thermal Condensing Supply Abandoned Proposed Abandoned/Removed Removed Out of Service

Thermal Chilled Water Return Proposed/Temporary Under Repair/Construction In Service

Thermal Chilled Water Supply Proposed/Temporary Under Repair/Construction In Service

Thermal Conventional High Temp W Return Proposed/Temporary Under Repair/Construction In Service

Thermal Conventional High Temp W Supply Proposed/Temporary Under Repair/Construction In Service

Thermal Conventional Return Proposed/Temporary Under Repair/Construction In Service

Thermal Conventional Supply Proposed/Temporary Under Repair/Construction In Service

Thermal Steam Trap Return Proposed/Temporary Under Repair/Construction In Service

Thermal Steam Trap Supply Proposed/Temporary Under Repair/Construction In Service

Thermal Condensing Return Proposed/Temporary Under Repair/Construction In Service

Thermal Condensing Supply Proposed/Temporary Under Repair/Construction In Service Thermal Outage and Repair Water Cathodic Protection Anode Water Cathodic Protection Bond Junction Water Cathodic Protection Rectifier Water Cathodic Protection Test Point Water Cathodic Protection Bond Wire Water Cathodic Protection Rectifier Cable Water Control Valve

Operational Water Fire Hydrant Classes Unknown Red Cap (Less than 500 GPM) Orange Cap (500-999 GPM) Green Cap (1000-1499 GPM) Blue Cap (1500 GPM or greater) Water Fitting Water Hydrant Water Meter Water Pump Water Pump Station Water Source Water Treatment Point

Abandoned Water Main Line Abandoned Proposed Abandoned/Removed Removed Out of Service

Abandoned Water Service Line Abandoned Proposed Abandoned/Removed Removed Out of Service

Water Main Line In Service Raw Water In Service Fire Protection In Service Non Potable Water In Service Potable Water

Water Service Line In Service Fire Protection In Service Non Potable Water In Service Potable Water Operational Status Other Fire Protection Water Water Treatment Water Well Resource Water Outage and Repair Building Label Building Airfield Label Road Label Airfield Surface Road Installation Boundary

July 1, 2024 0 50 10025 ft

0 10 205 m

1:564

1608931534C Callout Primary Elec to Remain

1608931534C Callout Transformer to Remain

1608931534C Callout Remove Water Service Back to Main

1608931534C Callout Water Main

1608931534C Callout Storm Drainage Cap at building

1608931534C Callout Remove Sign

1608931534C Callout Fire Hydrant to Remain

1608931534C Callout Exist. Elec. Service for Parking Lot to be Removed During Demolition and Reset after Completion.

1608931534C Callout Remove all HVAC

1608931534C Callout Exist. Parking Lots to Remain, Do Not Disturb

1608931534C Line

1608931534C Callout Remove Bldg Elec Service and Conduit Back to Transformer.

1608931534C Callout Cap Gas Line, Return Regulator to Gov.

1608931534C Text Box Revised 26 Aug 2024 (added sheet)

Bldg Elec. Service

1608931534C

Parking Lot Elec. Service to be Relocated

B1413

Building Label Building Installation Boundary

August 23, 2024 0 50 10025 ft

0 10 205 m

1:564

Polygon

1608931534C Callout Remove Sidewalk.

Preserve Exist. Curb

1608931534C Callout Remove All Sidewalk Along North Side

1608931534C Callout Remove Exist Sidewalk.

Preserve Exist Curb.