Attachment 16- Recology- Waste-Acceptance-Criteria-2023.07.31.pdf
PDF 112 KB Posted
- Attached to
- Replace Utility Well #9 Beale AFB
- Solicitation number
- FA468624R0006
About this file
This document outlines the Sampling Requirements and Acceptance Criteria for waste materials accepted at the Recology Hay Road and Recology Ostrom Road facilities. It provides details on the sampling frequency, required analytical testing, and acceptance criteria for various contaminants and waste types, including petroleum hydrocarbons, metals, and other potentially toxic substances. The document serves as a guideline for generators to follow when preparing waste materials for delivery to the Recology facilities. It specifies the maximum allowable concentrations for contaminants based on California regulations, and outlines the procedures for additional testing if threshold levels are exceeded. The document does not appear to be directly related to a federal contract opportunity, but rather provides general operational guidelines for the Recology facilities.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sampling Requirements and
Acceptance Criteria
Recology Hay Road
6426 Hay Road
Vacaville, CA 95687
Recology Ostrom Road
5900 Ostrom Road
Wheatland, CA 95692
Revised: 7/31/2023
Recology™
WASTE ZERO
Sampling Requirements and Acceptance Criteria
Page 2 of 3 Rev: 7/2023
Sampling Requirements
Project Size Cubic Yards per 4:1 Composite Sample
0 cy - 2,500 cy 1 sample per each 250 cy
2,501 cy – 5,000 cy
10 samples for first 2,500 cy + 1 sample per each additional 500 cy
5,001 cy – 8,000 cy
15 samples for first 5,000 cy + 1 sample per each additional 750 cy
8,001 cy - 10,000 cy
19 samples for first 8,000 cy + 1 sample per each additional 1,000 cy
>10,001 cy
21 samples for first 10,000 cy + 1 sample per each additional 2,500 cy
Discrete samples are assigned a sampling frequency of two times the composite sampling frequency. The sampling frequency for 4:1 composite samples is found on the table above. Recology reserves the right to require the generator to perform additional analytical testing for any potential hazardous waste pursuant to the guidelines outlined in Chapter 11 of CCR Title 22. Please contact Recology to confirm sampling requirements and required testing.
Analytical results must originate from a CELAP certified laboratory.
Soil Analysis Guidelines
Contaminant Required Analyses EPA Methods
Gasoline, Leaded
TPH – Gasoline
BTEX
Total Lead
EPA 5030/8015
EPA 8020/8260
TTLC-Lead
Gasoline, Unleaded
TPH – Gasoline
BTEX
EPA 5030/8015
EPA 8020/8260
Diesel TPH – Diesel
BTEX
EPA 3550/8015
EPA 8020/8260
Jet Fuel
(A, A-1, B, JP-
1,4,5,6,8)
TPH - Jet Fuel (A, A-1, B, JP- 1,4,5,6,8)
BTEX
EPA 3550 or 5030/8015
EPA 8020/8260
Motor Oil TPH – Motor Oil
BTEX
EPA 3550/8015
EPA 8020/8260
Hydraulic Oil TPH – Hydraulic Oil
BTEX
EPA 3550/8015
EPA 8020/8260
Bunker Oil TPH – Bunker Oil
BTEX
EPA 3550/8015
EPA 8020/8260
Fuel Oil TPH – Fuel Oil
BTEX
EPA 3550/8015
EPA 8020/8260
Kerosene TPH – Kerosene
BTEX
EPA 3550/8015
EPA 8020/8260
Waste Oil
TPH – Waste Oil TPH – Diesel TPH – Gasoline VOC’s SVOC’s Luft 5 Metals (Cd, Cr, Pb, Ni, Zn) PCB’s Dioxins (if PCP’s are detected)
EPA 3550/8015
EPA 3550/8015
EPA 5030/8015
EPA 8260
EPA 8270
TTLC – Metals
EPA 8080
EPA 8280
This document serves as a guideline only. Additional testing may be required.
Please contact Recology to obtain waste stream specific sampling requirements.
Recology™
WASTE ZERO
Sampling Requirements and Acceptance Criteria
Page 3 of 3 Rev: 7/2023
Metals Acceptance Criteria (CCR Title 22)
METAL
TTLC
(mg/kg)
STLC
Threshold (10x STLC)
STLC
(mg/l)
TCLP
(mg/l)
Antimony (Sb) 500 150 15 -
Arsenic (As)* 500 50 5 5
Barium (Ba)* 10,000 1,000 100 100
Beryllium (Be) 75 7.5 0.75 -
Cadmium (Cd)* 100 10 1 1
Chromium (Cr)* 2,500 50 560/5 5
Cobalt (Co) 8,000 800 80 -
Copper (Cu) 2,500 250 25 -
Lead (Pb)* 1,000 50 5 5
Mercury (Hg)* 20 2 0.2 0.2
Molybdenum (Mo) 3,500 3,500 350 -
Nickel (Ni) 2,000 200 20 -
Selenium (Se)* 100 10 1 1
Silver (Ag)* 500 50 5 5
Thallium (Tl) 700 70 7 -
Vanadium (Va) 2,400 240 24 -
Zinc (Zn) 5,000 2,500 250 -
Total concentrations cannot equal or exceed TTLC values. If total concentrations equal or exceed 10x STLC, a WET (Waste Extraction Test) is required. WET results cannot equal or exceed the STLC values. *If total concentrations equal or exceed 20x TCLP, a TCLP is required. TCLP results cannot equal or exceed the TCLP values.
Total Petroleum Hydrocarbons Acceptance Criteria
TPH Range Threshold
Gasoline 8,000 mg/kg
Diesel 8,000 mg/kg
Jet Fuel 8,000 mg/kg
Motor Oil 25,000 mg/kg
Hydraulic Oil 25,000 mg/kg
Bunker Oil 25,000 mg/kg
Fuel Oil 25,000 mg/kg
TRPH 25,000 mg/kg
Oil & Grease 25,000 mg/kg
Ignitability and toxicity testing are required if the constituents above exceed the listed threshold.
RCI & Toxicity Acceptance Criteria (CCR Title 22)
Non-Reactive (Reactivity) pH > 2.0 or pH < 12.5 (Corrosivity)
Flash Point ≥140°F (60°C) (Ignitability)
Acute Aquatic 96-hour
LC50 ≥ 500mg/L
(Toxicity)
Potentially Toxic Substances (CCR Title 22)
Substance
TCLP
(mg/l)
STLC
(mg/l)
TTLC
(mg/kg)
Aldrin N/A 0.14 1.4 Benzene 0.5 N/A N/A Carbon tetrachloride 0.5 N/A N/A Chlordane 0.03 0.25 2.5 Chlorobenzene 100 N/A N/A Chloroform 6.0 N/A N/A Cresol 200 N/A N/A
DDT, DDE,DDD N/A 0.1 1
2,4-Dichlorophenoxyacetic Acid
10 10 100
1,4-Dichlorobenzene 7.5 N/A N/A 1,2-Dichloroethane 0.5 N/A N/A 1,1-Dicholorethylene 0.7 N/A N/A Dieldrin N/A 0.8 8 2,4-Dinitrotoluene 0.13 N/A N/A Dioxin (2,3,7,8,-TCDD) N/A 0.001 0.01 Endrin 0.02 0.02 0.2 Heptachlor 0.008 0.47 4.7 Hexachlorobenzene 0.13 N/A N/A Hexachlorobutadiene 0.5 N/A N/A Hexachloroethane 3.0 N/A N/A Kepone N/A 2.1 21 Lead Compounds, Organic N/A N/A 13 Lindane 0.4 0.4 4 Methoxychlor 10 10 100 Methyl ethyl ketone (MEK) 200 N/A N/A Mirex N/A 2.1 21 Nitrobenzene 2.0 N/A N/A Pentachlorophenol 100 1.7 17 PCB's (all Aroclors) N/A 5 50 Pyridine 5.0 N/A N/A Tetrachloroethylene 0.7 N/A N/A Toxaphene 0.5 0.5 5 Trichloroethylene (TCE) 0.5 204 2040 2,4,5-Trichlorophenol 400 N/A N/A 2,4,6-Trichlorophenol 2.0 N/A N/A 2,4,5- Trichlorophenoxypropionic Acid
1 1 10
2,4,5-TP (Silvex) 1.0 N/A N/A Vinyl chloride 0.2 N/A N/A
Total concentrations cannot equal or exceed TTLC values. If total concentrations equal or exceed 20x TCLP, a TCLP is required. If total concentrations equal or exceed 10x STLC, a STLC is required Soluble concentration from the WET cannot equal or exceed STLC values.
TCLP results cannot equal or exceed the TCLP values.
Special Acceptance Provisions
Soil must be > 50% solids with no free liquids
Contact special waste acceptance team for sulfide and cyanide acceptance.
Sludge from a wastewater treatment plant must be >15% solids for secondary treated sludge and >20% solids for primary treated sludge.
File details come from the government source that posted it. Updated .