Attachment 1 Salient Characteristics - updated 17 Sep.docx

DOCX document 38 KB Posted

Attached to
Nitrogen Generator with Training
Solicitation number
FA466126Q0078
Issued by

About this file

This is a Salient Characteristics document outlining the specifications and requirements for a containerized high pressure nitrogen generator system to be delivered to Dyess Air Force Base for the Department of the Air Force Global Strike Command under Solicitation Number FA466126Q0078.

The primary deliverable is a skid-mounted or trailer-mounted nitrogen generator system capable of producing a minimum flow rate of 26 scfm at 95.5% nitrogen purity with adjustable output. The system must maintain a minimum storage pressure of 500 psig and discharge pressure of 400 psig, operate on 480VAC, 3-phase, 60Hz power, and fit within dimensions of 156 inches long by 78 inches wide by 74 inches tall while not exceeding 5,000 pounds. The design shall incorporate an air compressor feeding nitrogen membranes connected to a nitrogen booster compressor with 900 cubic feet of onboard storage capacity, enabling continuous operation for a minimum of 24 hours without interruption. The contractor must complete preliminary testing and system adjustments prior to delivery, followed by eight-hour acceptance testing at Simpro's facility demonstrating full compliance with production specifications. Delivery must occur within 120 days, with onsite installation, testing, and training to be completed within 14 days thereafter. The contractor shall provide a system matter expert/trainer for a minimum of three days of onsite training at Dyess Air Force Base, supply electronic operational manuals including vendor documentation, and furnish a minimum one-year warranty covering parts, workmanship, and equipment performance.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ITEM

NUMBER

Description
QUANTITY
UNIT
0001
Scope:

Containerize high pressure nitrogen compressor system meeting the following specifications

1
EA
0001.1
Skid Mounted or Trailer Mounted
1
EA
0001.2
This is the minimum Flow rate: 26 scfm @ 95.5% Nitrogen & be adjustable
1
EA
0001.3
Storage Pressure must meet a minimum 500psig
1
EA
0001.4
Discharge Pressure must be at a minimum of 400psig
1
EA
0001.5
Power: 480vac, 3ph, 60hz
1
EA
0001.6
Product must fit within the following Dimensions: 156” long x 78” wide x 74” tall
1
EA
0001.7
Weight: must not exceed 5,000 pounds
1
EA
0001.8
Design: Air Compressor feed to N2 Membranes to N2 Booster Compressor. Storage capacity @ 900 scf on board.
1
EA
0001.9
Self-generating nitrogen cart must be able to run sufficiently without any interruptions for a minimum of 24 hours
1
EA
0002
Testing:

Unit acceptance testing will be operated for 8 hours meeting all production specifications without issue.

Preliminary testing will be required for system adjustments and tuning. Testing will be at Simpro’s facility.

Preliminary testing should be completed by the manufacture prior to arrival, this is required for system adjustments and fine tuning, prior to delivery.

Testing and acceptance by the unit will be conducted at the unit after setup and before training.

1
EA
0003
Manuals and documentation:

Manuals will be electronic versions, including operational manuals and manuals supplied by vendors. This will also include CD’s if the vendor supplied.

1
EA
0004
Provide onsite delivery within 120 days.

Provide onsite installation, testing and training within 14 days after delivery:

*Company will provide a system matter expert/trainer to complete onsite training for a minimum of 3 days at Dyess Air Force Base

1
EA
0005
Provide a minimum one-year warranty for parts, workmanship, and performance of onsite equipment at Dyess Air Force Base
1
EA