Attachment 1 Generator Salient Characteristics.docx
DOCX document 28 KB Posted
- Attached to
- Nitrogen Generator with Training
- Solicitation number
- FA466126Q0078
About this file
This is a Salient Characteristics document outlining the technical specifications and deliverables for a containerized high-pressure nitrogen generator system required by the Department of the Air Force Global Strike Command under Solicitation Number FA466126Q0078.
The primary deliverable is a skid-mounted or trailer-mounted nitrogen generation system that must produce a minimum flow rate of 26 scfm at 95.5% nitrogen purity with adjustable output. The system must maintain a minimum storage pressure of 500 psig and discharge pressure of at least 400 psig, powered by 480VAC, three-phase, 60Hz electricity. The unit must be designed with an air compressor feeding nitrogen membranes connected to a nitrogen booster compressor, incorporating 900 scf onboard storage capacity. Dimensional constraints require the equipment to fit within 156" long by 78" wide by 74" tall, with a maximum weight of 5,000 pounds, and the system must operate continuously for a minimum of 24 hours without interruption. The contractor must complete onsite installation and delivery within 120 days at Dyess Air Force Base, excluding delays from payment, parts availability, or force majeure events. Additional requirements include eight-hour unit acceptance testing at the contractor's facility to verify all production specifications, provision of electronic operational and vendor manuals, onsite training by a system subject matter expert for a minimum of three days, and a one-year warranty covering parts, workmanship, and performance of the onsite equipment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Q and A For Nitrogne Generator 17 Sep (Amendment 3).docx | DOCX document | |
| Q and A For Nitrogne Generator 17 Sep.docx | DOCX document | |
| RFQ FA466126Q0078 - Nitrogen Generator 17 Sep 26.docx | DOCX document | |
| Attachment 1 Salient Characteristics - updated 17 Sep.docx | DOCX document | |
| Attachment 1 Salient Characteristics - updated 16 Sep.docx | DOCX document | |
| Attachment 2 FA466126Q0078 T C.pdf | ||
| RFQ FA466126Q0078 - Nitrogen Generator.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ITEM
NUMBER
| Description |
| QUANTITY |
| UNIT |
| 0001 |
| Scope: |
Containerize high pressure nitrogen compressor system meeting the following specifications
| 1 |
| EA |
| 0001.1 |
| Skid Mounted or Trailer Mounted |
| 1 |
| EA |
| 0001.2 |
| This is the minimum Flow rate: 26 scfm @ 95.5% Nitrogen & be adjustable |
| 1 |
| EA |
| 0001.3 |
| Storage Pressure must meet a minimum 500psig |
| 1 |
| EA |
| 0001.4 |
| Discharge Pressure must be at a minimum of 400psig |
| 1 |
| EA |
| 0001.5 |
| Power: 480vac, 3ph, 60hz |
| 1 |
| EA |
| 0001.6 |
| Product must fit within the following Dimensions: 156” long x 78” wide x 74” tall |
| 1 |
| EA |
| 0001.7 |
| Weight: must not exceed 5,000 pounds |
| 1 |
| EA |
| 0001.8 |
| Design: Air Compressor feed to N2 Membranes to N2 Booster Compressor. Storage capacity @ 900 scf on board. |
| 1 |
| EA |
| 0001.9 |
| Self-generating nitrogen cart must be able to run sufficiently without any interruptions for a minimum of 24 hours |
| 1 |
| EA |
| 0002 |
| Testing: |
Unit acceptance testing will be operated for 8 hours meeting all production specifications without issue. Preliminary testing will be required for system adjustments and tuning. Testing will be at Simpro’s facility.
| 1 |
| EA |
| 0003 |
| Manuals and documentation: |
Manuals will be electronic versions, including operational manuals and manuals supplied by vendors. This will also include CD’s if the vendor supplied.
| 1 |
| EA |
| 0004 |
| Provide onsite installation within 120 days ready for testing, excluding payment delays, parts available, and force majeure. |
| 1 |
| EA |
| 0005 |
| Company will provide a system matter expert/trainer to complete onsite training for a minimum of 3 days at Dyess Air Force Base |
| 1 |
| EA |
| 0006 |
| Provide a minimum one-year warranty for parts, workmanship, and performance of onsite equipment at Dyess Air Force Base |
| 1 |
| EA |