4 7/8"
1A
2 1/8"
BOTTOM OF EXISTING
ROOF DECK
CEILING AS SCHEDULED
5/8" GWB
1 1/2" 'Z' FURRING
@ 16" O.C.
EXISTING WALL
BASE AS SCHEDULED
FLOORING AS SCHEDULED
EXISTING FLOOR LINE
4" MI
N.
6 5/8"
CEILING AS
SCHEDULED
5/8" GWB
6" METAL
STUD
FRAMING
@ 16" O.C.
BASE AS
SCHEDULED
FLOORING AS
SCHEDULED
EXISTING
FLOOR LINE
4" MI
N.
3A 3B
BASE AS SCHEDULED
FLOORING AS SCHEDULED
EXISTING FLOOR LINE
5/8" GWB EACH SIDE
3 5/8" METAL STUD
FRAMING @ 16" O.C.
BOTTOM OF EXISTING
ROOF DECK
BATT INSULATION
AT 3A ONLY
WALL TO STRUCTURE
CEILING AS SCHEDULED
4 7/8"
4A 4B
BASE AS
SCHEDULED
FLOORING AS
SCHEDULED
EXISTING
FLOOR LINE
5/8" GWB EACH SIDE
3 5/8" METAL STUD
FRAMING @ 16" O.C.
BATT INSULATION
AT 4A ONLY
CEILING AS
SCHEDULED
4" MI
N.
1B
RIGID INSULATION
AT 1A ONLY
4 1/4"
5A 5B
BASE AS
SCHEDULED
FLOORING AS
SCHEDULED
EXISTING
FLOOR LINE
5/8" GWB
3 5/8" METAL STUD
FRAMING @ 16" O.C.
BATT INSULATION
AT 5A ONLY
CEILING AS
SCHEDULED
4" MI
N.
SPRAY FOAM INSULATION
AT 1A ONLY
5/8"
CEILING AS
SCHEDULED
5/8" GWB
EXISTING WALL
BASE AS
SCHEDULED
FLOORING AS
SCHEDULED
EXISTING
FLOOR LINE
4" MI
N.
7 1/4"
BASE AS
SCHEDULED
FLOORING AS
SCHEDULED
EXISTING
FLOOR LINE
5/8" GWB
EACH SIDE
6" METAL STUD
FRAMING @ 16" O.C.
BATT INSULATION
CEILING AS
SCHEDULED
4" MI
N.
+- 16'-10"
3 1/8"
CEILING AS
SCHEDULED
5/8" GWB
2 1/2" METAL STUD
FRAMING @ 16" O.C.
EXISTING WALL
BASE AS
SCHEDULED
FLOORING AS
SCHEDULED
EXISTING
FLOOR LINE
4" MI
N.
6 1/8"
BASE AS SCHEDULED
FLOORING AS SCHEDULED
EXISTING FLOOR LINE
2 LAYERS OF
5/8" GWB EACH
SIDE
3 5/8" METAL STUD
FRAMING @ 16" O.C.
BOTTOM OF EXISTING
ROOF DECK
BATT INSULATION
WALL TO STRUCTURE
CEILING AS SCHEDULED
10'-0"
+- 16'-10"
BOTTOM OF EXISTING
ROOF DECK
WALL TO STRUCTURE
AT 7A ONLY
7A
3/4" FIRE-STOP
SEALANT EACH SIDE
AT FIRE-RATED AND
SMOKE-RATED WALLS
ONLY
8" x 18-GA SHEET
METAL PLATE AT
FIRE-RATED WALLS
ONLY
FILL DECK VOIDS WITH
SAFING INSULATION AT
FIRE-RATED WALLS
ONLY
3/4" FIRE-STOP
SEALANT EACH SIDE
AT FIRE-RATED AND
SMOKE-RATED WALLS
ONLY
8" x 18-GA SHEET
METAL PLATE AT
FIRE-RATED WALLS
ONLY
FILL DECK VOIDS
WITH SAFING
INSULATION AT
FIRE-RATED WALLS
ONLY
3/4" FIRE-STOP
SEALANT EACH SIDE
AT FIRE-RATED AND
SMOKE-RATED
WALLS ONLY
8" x 18-GA SHEET
METAL PLATE AT
FIRE-RATED WALLS
ONLY
FILL DECK VOIDS WITH
SAFING INSULATION AT
FIRE-RATED WALLS
ONLY
AT BEAMS, BAR JOISTS AND
OTHER PENETRATIONS:
- AT FIRE AND SMOKE-RATED
WALLS, SEAL AROUND
PENETRATIONS WITH
FIRESTOPPING SEALANT
- AT OTHER WALLS EXTEND
GWB TO WITHIN 1 INCH OF ALL
PENETRATIONS
AT BEAMS, BAR JOISTS AND
OTHER PENETRATIONS:
- AT FIRE AND SMOKE-RATED
WALLS, SEAL AROUND
PENETRATIONS WITH
FIRESTOPPING SEALANT
- AT OTHER WALLS EXTEND
GWB TO WITHIN 1 INCH OF ALL
PENETRATIONS
+- 16'-10"
AT BEAMS, BAR JOISTS
AND OTHER PENETRATIONS:
- AT FIRE AND SMOKE-RATED
WALLS, SEAL AROUND
PENETRATIONS WITH
FIRESTOPPING SEALANT
- AT OTHER WALLS EXTEND
GWB TO WITHIN 1 INCH OF
ALL PENETRATIONS
VWC-4
WOOD BASE; SEE 2A/A-604
WOOD TRIM;
SEE 2B/A-604
VWC-4
P-9
P-9VWC-4
VWC-4
PLAN VIEW
P-9
VWC-4 VWC-4
2'-9 1/4" - F.V.
TO MATCH
ADJACENT
EXISTING
CORRIDORS
P-9
A-601
R O
O M
F
I N
I S
H
S
C H
E D
U L E
A
N D
W
L L
T
Y P
E S
G R
A N
D
F
O R
K S
B
N
D
C O
N T
R A
C T
S
E
L E
M E
N T
C
I V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
A B C
D E F G
Sheet of
NUMBER
REFERENCE
SHEET
A
R
M
B
I L
I T
Y
C
O M
M A
N D
D E
P A
R T
M E
T
T
H
R
C E
D R
A W
I N
G
N
U M
B E
R
P L O
T
S
C A
L E
T
O
F
S
I Z
E
P L O
T
D
A T
E
C H
K
B
Y
D W
N
B
Y
D E
S I G
N E
D
B
Y
F I L
M
E
D A
T E
S y m b o l D e s c r i p t i o n D a t e
A p p r o v e d S y m b o l A p p r o v e d D a t e
D e s c r i p t i o n
O
C
G J H
G J H
K L M
O
I S
S U
B
O N
S T
R U
C T
I O
N
NOTES
ROOM FINISH SCHEDULE
NO. DESCRIPTION FLOOR BASE
NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING
MAT. FIN. MAT. FIN. HEIGHTMAT. FIN. MAT. FIN. MAT. FIN.
C102 CORRIDOR CPT-4 EX WD EX GWB EX GWB EX GWB EX GWB EX ATC
C103 CORRIDOR CPT-4 WD GWB NOTE 1 GWB NOTE 1 GWB NOTE 1 GWB NOTE 1 ATC-1/GWB P-9 VARIES
C104 CORRIDOR CPT-4 WD GWB NOTE 1 GWB NOTE 1 GWB NOTE 1 GWB NOTE 1 ATC-1/GWB P-9 VARIES
C105 CORRIDOR CPT-4 WD GWB NOTE 1 GWB NOTE 1 GWB NOTE 1 GWB NOTE 1 ATC-1/GWB P-9 VARIES
C107 CORRIDOR EX CONC -- EX CMU -- GWB NOTE 2 EX CMU -- EX CMU -- EXP -- --
C108 CORRIDOR CPT-4 WD GWB NOTE 1 GWB NOTE 1 GWB NOTE 1 GWB NOTE 1 ATC-1/GWB P-9 VARIES
C108A CORRIDOR EX CONC -- GWB NOTE 2 EX CMU -- -- -- EX CMU -- EXP -- --
C111 CORRIDOR EX CONC -- EX CMU NOTE 2 EX CMU -- EX CMU -- -- -- EXP -- --
300 VESTIBULE CPT-5 RB-1 GWB P-8 GWB P-8 GWB P-8 GWB P-8 ATC-2 -- 10'-0"
301 BREAK ROOM VT-1 RB-1 GWB P-8 GWB P-8 GWB P-8 GWB P-2 ATC-1 -- 9'-0"
302 CORRIDOR CPT-2 RB-1 -- -- GWB P-8 GWB P-8 -- -- ATC-1 -- 9'-10"
303 STORAGE VCT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ATC-1 -- 9'-0"
304 OPEN OFFICE CPT-2 RB-1 GWB VWC-1 GWB P-8 -- -- GWB P-8 ATC-1 -- 9'-10"
305 SIPR CPT-2 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ATC-1 -- 9'-0"
306 OFFICE 2 CPT-2 RB-1 GWB P-8 GWB P-3 GWB P-8 GWB P-8 ATC-1 -- 9'-0"
307 OFFICE 1 CPT-2 RB-1 GWB P-8 GWB P-3 GWB P-8 GWB P-8 ATC-1 -- 9'-0"
308 COMMANDER CPT-1 RB-1 GWB VWC-2 GWB VWC-2 GWB VWC-2 GWB VWC-2 ATC-1 -- 9'-0"
309 STORAGE VCT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ATC-1 -- 9'-0"
310 OFFICE 4 CPT-2 RB-1 GWB P-3 GWB P-8 GWB P-8 GWB P-8 ATC-1 -- 9'-0"
311 OFFICE 3 CPT-2 RB-1 GWB P-8 GWB P-8 GWB P-3 GWB P-8 ATC-1 -- 9'-0"
312 CORRIDOR CPT-2 RB-1 GWB P-2 -- -- GWB P-8 GWB P-8 ATC-1 -- 9'-10"
313 OFFICE 5 CPT-2 RB-1 GWB P-8 GWB P-8 GWB P-8 GWB P-3 ATC-1 -- 9'-0"
314 OFFICE 6 CPT-2 RB-1 GWB P-8 GWB P-3 GWB P-8 GWB P-8 ATC-1 -- 9'-0"
315 CONFERENCE CPT-1 RB-1 GWB P-8 GWB VWC-3 GWB P-8 GWB P-8 ATC-1/GWB P-8 VARIES
316 CONFERENCE STORAGE VCT-1 RB-1 GWB P-8 GWB P-8 GWB P-8 GWB P-8 ATC-1 -- 9'-0"
317 OPEN OFFICE CPT-3 RB-1 GWB P-2 GWB P-8 GWB P-8 GWB P-8 ATC-1 -- 9'-0"
318 OFFICE B CPT-3 RB-1 GWB P-8 GWB P-8 GWB P-2 GWB P-8 ATC-1 -- 9'-0"
319 OFFICE A CPT-3 RB-1 GWB P-2 GWB P-8 GWB P-8 GWB P-8 ATC-1 -- 9'-0"
320 CORRIDOR CPT-2 RB-1 -- -- GWB P-8 GWB P-8 GWB P-8 ATC-1 -- 9'-10"
321 TRAINING OFFICE CPT-2 RB-1 GWB P-8 GWB P-2 GWB P-8 GWB P-8 ATC-1 -- 9'-0"
322 OPEN OFFICE CPT-3 RB-1 GWB P-3 GWB P-2 GWB P-8 GWB P-8 ATC-1 -- 9'-0"
323 OFFICE CPT-3 RB-1 GWB P-8 GWB P-2 GWB P-8 GWB P-8 ATC-1 -- 9'-0"
324A ELECTRICAL EX CONC -- GWB P-1 GWB P-1 EX CMU P-1 EX CMU P-1 EXP -- --
ATC ACOUSTICAL TILE CEILING
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CPT CARPET
EX EXISTING
EXP EXPOSED
GWB GYPSUM WALLBOARD
P PAINT
RB RUBBER BASE
SC SPECIAL COATING
VCT VINYL COMPOSITION TILE
VT VINYL TILE
VWC VINYL WALLCOVERING
WD WOOD
ROOM FINISH SCHEDULE LEGEND
ROOM FINISH SCHEDULE NOTES
1. SEE DETAIL 2/A-601 FOR WALL FINISHES IN THIS CORRIDOR.
2. PAINT TO MATCH EXISTING.
NOTE: FINISHES AT ALL ROOMS SHOWN ON FLOOR PLAN BUT NOT LISTED ON THIS SCHEDULE ARE EXISTING TO REMAIN.
SCALE: 3/4" = 1'-0" 2'1'0 4'
WALL TYPES
SCALE: 3/4" = 1'-0" 2'1'0 4'
TYPICAL CORRIDOR WALL ELEVATION
NOTE: REFER TO COLOR SCHEDULE IN SPEC. SECTION 09 06 90 FOR ALL
INTERIOR FINISHES.
C