2012 MATOC Atch 10 Fairchild AFB Architectural Compatibility Plan.pdf

PDF 9 MB Posted

Attached to
Multiple Award Task Order Contract (MATOC) at Fairchild AFB WA Federal contract opportunity
Solicitation number
FA4620-12-R-B002
Issued by
Department of the Air Force Air Mobility Command

About this file

Atch 10 Fairchild AFB Architectural Compatibility Plan

View the file

Other files for this federal contract opportunity

Other files attached to Multiple Award Task Order Contract (MATOC) at Fairchild AFB WA, newest first.
File Type Posted
Amendment 03 - Q A.pdf PDF
SOW REVISED 29 May 2012 Repair Fire Sprinklers Corner Tower Stairs.pdf PDF
Appendix B Haz Mat Survey Revised 29 May 2012.pdf PDF
FA4620-12-R-B002 FINAL.pdf PDF
Amendment 01 - 2012 Matoc.pdf PDF
2012 MATOC Atch 8d WD Residential 6Apr12 - Spokane County.pdf PDF
2012 MATOC Solicitation.pdf PDF
2012 MATOC Atch 11 Fairchild AFB Operational Climatic Data Summary.pdf PDF
2012 MATOC Atch 7 Subcontractor Release.pdf PDF
2012 MATOC Atch 1 MATOC Specs Rev 3 May 12.pdf PDF
2012 MATOC Atch 4 Past Performance Info 1 May 12.pdf PDF
2012 MATOC Atch 2 Seed Proj 10-0184 SOW Repair Fire Sprinklers Dated 16 Mar 12 with Attachments.pdf PDF
2012 MATOC Atch 5 Past Perf cover letter.pdf PDF
2012 MATOC Atch 6 SOW for Orientation Seminar.pdf PDF
2012 MATOC Atch 2 MATOC Seed Project TORFP Cover Ltr.pdf PDF
2012 MATOC Atch 5 Past Perf Questionnaire rev 3 May 12.pdf PDF
2012 MATOC Atch 3 MATOC Seed Proj Price Schedule.pdf PDF
2012 MATOC Atch 8b WD Heavy 6Apr12 —
2012 MATOC Atch 8c WD Highway 4May12 - Statewide.pdf PDF
2012 MATOC Atch 8a WD Building 6Apr12 - Spokane County.pdf PDF
2012 MATOC Atch 9 Base Design Standards 2012.pdf PDF
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fairchild Air Force Base architectural compatibility plan an architecture of community

Vision

An Architecture of Community is the long-range vision for Fairchild Air Force Base.

This is a vision of excellence displayed in a high-quality corporate image for facilities, the landscape, and the environment. It is expressive of the architectural character, climatic factors, and cultural influences typically associated with eastern Washington.

Architectural compatibility and Community can be achieved by understanding the vision for the base and by refining its design vocabulary. Successful examples of high quality facilities, landscaping, and streetscapes are presented in this Architec-tural Compatibility Plan (ACP). These examples depict the design standards that will ensure compatibility and achieve the vision of excellence.

table of contents table of contents

Introduction

Design Standards

Basewide

Buildings

Wall Systems

Roof Systems

Entrances

Windows and Doors

Ancillary Structures

Screens and Enclosures

Landscaping

Walkways and Paths

Roads

Parking

Signs

Site Furnishings

Lighting

Utilities

Flightline / Industrial

Family Housing

Implementation

Appendices

Materials and Colors..................................A1

Exterior Color Applications......................A2

Landscape Materials..................................A3

Related Plans and Guidelines.................A4

ACRB Project Checklist...........................A5

Index .... .........................................................A6

Notes.... .........................................................A7

2 3architectural compatibility plan - Fairchild Air Force Base

The Architectural Compatibility Plan (ACP) defines a clear design vo cab u lary to be used throughout the base, providing specific standards for all aspects of exterior design. Compatible architecture is ac com plished with similar buildings, using common design forms, details, materials, site features, landscaping, and streetscapes.

Quality and compatibility are achieved through creating a unified visual environment that is based on an Architec-ture of Community, similar to a campus or small town.

The principal design goal is to direct de vel op ment at Fairchild AFB toward a livable, attractive, and cohesive installation.

The ACP provides the design standards that will help to build com pat i ble facilities and a quality environment.

Implementation of the stan dards will result in the creation of community.

introduction

Purpose

The pur pose of the ACP is to de fine de-sign stan dards for build ings, site de vel -op ment, and streetscapes that serve to in te grate the vi su al char ac ter through out the base.

The ACP will help en sure con sis tent qual i ty de sign de ci sions by com mand ers, plan ners, ar chi tects, en gi neers, main te -nance staff, and res i dents. It pro motes clear, con cise com mu ni ca tion be tween the Fairchild AFB personnel and de sign professionals.

This plan ap plies to self-help in i ti a tives, small projects, and op er a tions and main te nance activities as well as large con struc tion efforts.

The ACP is ref er enced from and sup ports the Fairchild AFB Gen er al Plan as a key com po nent plan.

introduction

Review Board (ACRB). The Implementa-tion Section defines methods to facilitate the coordination and approval of design submittals.

Finally, the Appendices provide ad di -tion al information including an index; a list of building materials, site amenities, colors, and landscape materials; and a checklist for the ACRB and project per-sonnel. Use the Ap pen di ces in conjunc-tion with the general text of the ACP as a quick ref er ence to specific materials and color specifications.

A post er is avail able upon re quest that dis plays pho to graph ic ex am ples of the Fairchild AFB community.

How to Use This Plan

The ACP de fines three architectural set-tings: Basewide, Flightline / In dus tri al, and Fam i ly Hous ing (see the map be low).

Gen er al and spe cif ic de sign stan dards for all build ings are in clud ed in the Basewide set ting. Basewide stan dards shall be ap plied to all projects, including the Air National Guard Campus. When a project is lo cat ed in the Flightline / In-dus tri al or Fam i ly Hous ing set ting, more spe cif ic stan dards from those Sec tions of the ACP shall be applied.

The Im ple men ta tion Sec tion of the ACP out lines key el e ments to en sure suc cess in designing and constructing excellent facilities. It discusses the traditional design process, highlights the im por -tance of site analysis, and describes the role of the Architectural Compatibility

Basewide

Flightline / In dus tri al

Family Housing

Brown Brick Area

Architectural Settings

4 5architectural compatibility plan - Fairchild Air Force Base design stan dards

Design standards for buildings and supporting elements are outlined in this section. These standards encourage architectural compatibility using common forms, materials, colors, and architectural details.

The goal is to design ex cel lent facilities that satisfy all of these priorities. The first priority is to achieve architectural compatibility for Fairchild Air Force Base as a whole. The second priority is compatibility within an architectural setting or sub-area. Outstanding designs for individual buildings or facilities are the third priority.

design standards - basewide

Fairchild AFB has a foundation for architectural unity. The existing architecture depicts a predominant materials palette and a consistency of material detailing. The following design standards are applicable to the entire installation, to both host and tenant organizations.

Site planning and site development issues contribute significantly to the architectural context. Building setbacks and the scale and definition of space are as fundamental to creating architectural compatibility as consistent facade designs. Develop exterior spaces to promote pedestrian use and activity and to connect buildings and the land-scape. Use the landscape with other visual elements to create greater continuity.

BUILDINGS

Achieving com pat i bil i ty among build ings is es sen tial in cre at ing an Ar chi tec ture of Com mu ni ty. De vel op fa cil i ties with a com mon de sign theme and char ac ter to en hance ar chi tec tur al com pat i bil i ty.

Unity is the goal, not conformity.

Style / Form n Emphasize horizontal pro por tions on building elements.

n Rectangular elements are the stan-dard for major building masses. Use clean, simple, contemporary forms and avoid curves or angular elements in plan.

n Develop a strong relationship be-tween buildings and exterior spaces.

n Articulate building facades to create areas of shade and shadow.

n Use masonry detailing as accents in walls combined with sloped roofs and modest eaves.

Scale / Massing n Reduce the monumental ap pear ance of large structures by de vel op ing smaller massing components.

n Combine functions whenever pos-sible to avoid a proliferation of small independent structures.

n Break up the mass of large struc-tures to allow for slope roofs to the max i mum extent.

Existing Buildings n Match the existing materials for addition / alteration projects unless a significant change to the exterior envelope is included.

n Whenever possible bring existing facilities into compliance.

basewide

6 7architectural compatibility plan - Fairchild Air Force Base

WALL SYSTEMS

Walls provide the principal details and architectural features for buildings.

These contribute significantly to the character of the base. Limit the pal-ette of materials that is to be used and integrate landscape berming when it is appropriate. Consistent use of colors and materials will bind the base together and reduce visual clutter caused by too much diversity.

Brick n Use red brick in a running bond pat-tern with tooled joints.

n The brown brick area follows the basewide standards unless specifi-cally noted.

n Brick may be used when appropriate for lintels or sills. Detailing should emulate bearing wall construction.

n Conceal expansion joints with down-spouts or locate them at transitions in the wall such as at pilasters or reveals.

n Use natural color portland cement mortar.

n Efflorescence in masonry work is unacceptable. All materials shall be classified as low-efflorescence.

Architectural Precast n Precast is permitted in the brown brick areas for administrative and community facilities.

n Precast is appropriate for lintels, sills, belt courses, and friezes.

n Other facade elements made of precast should be used sparingly to ensure that brick remains the promi-nent material.

n Natural is the standard color for precast concrete.

n Detailed designs and patterns may be cast into the pieces to create an indi-vidual character for a single facility or complex.

n Site-cast components are acceptable per ACRB approval.

design standards - basewide

Other Materials n Limit pre-finished metal wall panels to large industrial / flightline facilities and special applications only with ACRB approval.

n Factory finish all exposed metals with a powder-coat application such as Kynar-500.

n Joint sealants in brick shall match mortar color. When adjacent sur-faces are the same color use a darker joint sealant in the same color.

Accents / Detailing n Facilities shall demonstrate a greater application of detailing.

n Architectural accents such as lintels, sills, belt courses, pilasters, and col-umns or other contextual details are encouraged to break up flat facades and add visual interest.

Wall Components n Organize and coordinate placement of all mechanical, electrical, lighting, communication and other building components.

n Integrate vertical components such as downspouts and control joints into the overall organization.

n Do not expose conduits, cables, and piping on walls.

n All gas meters, fire bells, vents, lou-vers, and electrical / communication boxes shall match the wall surface color on which the equipment is mounted.

8 9architectural compatibility plan - Fairchild Air Force Base

ROOF SYSTEMS

Roof color, material, and form are promi-nent features and play a significant role in architectural compatibility. Ensure these are comparable in shape, slope, material, and color throughout the base.

Configuration n Use a combination of gabled and hipped roofs as the primary building form for all facility types.

n Open gabled elements may be used to accent entries. Gabled end walls may also be used.

n Flat roofs with continuous parapet walls are discouraged and should be limited to special use facilities when approved by the ACRB.

n Use overhangs proportional to the size and height of the building.

n Low-sloped roofs are only allowed for larger structures in combination with hipped roofs, or to match existing conditions on renovation / alteration projects.

n Divert water away from building entrances.

n Protect entrances from falling snow and ice. Use snow guards at en-trances and when sidewalks are next to a building.

Materials and Color n Use standing seam metal roofing on sloped roofs. 16" wide panels with a 1 1/2 " high seam is the standard.

n Roofing shall be Weathered Copper color. Soffits shall match the roof color.

n Roof flashing shall match the roof material and color.

n Stepped flashing at the intersection of roofs and walls shall match roof color.

n Membrane roofing for low-sloped roofs may be used only with ACRB approval. A warranted minimum slope of 1/2 : 12 is required.

n Mill finish may be used on low sloped roofs that are not visible.

design standards - basewide

Fascias, Gutters, and Downspouts n Incorporate continuous metal fascias that are proportional to match the scale of the roof.

n Fascia finish shall match the roof color when occurring with metal roofing.

n Properly proportioned turn-down standing seam metal fascias are permitted with ACRB approval.

n Gutters on sloped roofs are required for entrances and shall be factory finished to match the roof color.

n Integrate open-face downspouts with architectural details and match their color with that of the roof on brick buildings.

n On painted buildings paint down-spouts to match the wall color.

n Interior roof drains and open scup-pers are allowed only with approval of the ACRB. Do not use internal gutters.

n Provide concrete splash blocks at grade draining or connected directly to the storm drainage system.

Roof Vents and Elements n Minimize, consolidate, and organize roof penetrations on the least visible side of the building.

n Ridge vents are preferred. Louver grilles at gabled end walls are acceptable.

n PVC pipes and other utility elements shall be screened or finished to match the roof color.

n Do not use rooftop mechanical units.

When required, minimize the nega-tive visual effects with screening to match the roof color. Mechanical roof pits are not allowed.

n Consider the use of dormer vents to conceal and screen exhaust fans.

n Make mechanical vent sizes and shapes consistent with architectural elements.

n Avoid roof-mounted antennas.

10 11architectural compatibility plan - Fairchild Air Force Base

ENTRANCES

Entrances act as a transitional element from exterior to interior and provide opportunities to create a focal point on a façade. They establish a user’s first im-pression and delineate the importance of the building by the size and architectural detailing of the entrance structure.

General n Ensure the building entrance is clearly visible and highlighted as a prominent feature.

n Projected entrance features with gabled or hipped roof forms are preferred.

n Create enclosed vestibules and weather-protected transition spaces at entrances.

n Integrate handicapped ramps into designs.

n Provide indirect lighting at building entrances integrated into the design.

Primary Entrances n Provide overhead enclosure for weather protection.

n Use accent pavers or colored con-crete in approach walkways or at entry plazas.

n Locate newspaper, vending ma-chines, and similar elements out of view to avoid visual clutter.

Secondary Entrances n Reflect subtly the character of the pri-mary entrances but with lesser detail.

n Recessed entries are acceptable to provide areas of shade and weather protection.

Service Entrances and Emergency Egress n Minimize visual impact with proper siting and access.

n Provide unobtrusive service entrances that are physically and visually separated from primary and secondary entrances.

n Incorporate egress structures such as stair towers into design.

n Use landscaping and screen walls to screen and separate loading docks.

n Do not use canopies at emergency egress doorways.

Arcades n These may be used as an extension of the building’s entrance.

n Integrate arcades with the building’s form, materials, and detailing.

Drop-offs and Porte-cocheres n Limit to special, high profile facilities and embellish corresponding amenities, design accents, and landscaping.

n Design as an integral part of the building entrance using the same style, form, and materials.

Handrails n Finish railings dark bronze anodized to match roof color.

n Integrate handrail designs with the facility design.

Plazas and Courtyards n The use of plazas and courtyards is encouraged at primary and second-ary entries.

n Use concrete surfacing with special joint patterns and/or brick or similarly colored concrete accent pavers with ACRB approval.

n Incorporate landscaping and lighting into the design.

design standards - basewide

WINDOWS AND DOORS

Windows and doors create a compliment in the facade and must be considered as individual details and for overall arrangement, order, and scale.

Openings n Use window type, size, placement and mullion pattern to emphasize overall architectural design.

n Set windows back at least 3” from the building facade.

n Incorporate operable windows with screens where possible.

n Transom windows / elements above doors / windows are encouraged.

Doors and Frames n Use dark bronze anodized aluminum storefront systems with thermal-break construction.

n Door, frame, and hardware colors shall match and be dark bronze anodized.

n Limit hollow metal frames to security doors, utility rooms, and outlying sites.

n All emergency egress and service doors and frames shall match adjacent surfaces.

n Sealants applied adjacent to windows and doors shall match frame color.

Glazing n Use dark bronze tinted, dual-pane insulated glass.

n Mirrored and plastic glazing shall not be used.

n Translucent fiberglass insulated panels are acceptable. Use clear glazing on outside and white glazing on inside with dark bronze frames.

n Ribbon windows may be used beneath eaves as an architectural feature.

Clerestories and Skylights n Integrate clerestories or low-profile skylights with building design.

n Clerestory windows shall be either glass or translucent insulated panels.

Security Screens n Electronic security systems or secu-rity glazing is preferred to physical screens or bars.

n Where physical barriers are required, develop simple rectangular designs that are unobtrusive.

12 13architectural compatibility plan - Fairchild Air Force Base

ANCILLARY STRUCTURES

Consistency in the color, materials, and form of ancillary structures provides con-tinuity in the outdoor spaces on the base and reduces overall visual clutter.

General n Coordinate the siting of all ancillary structures with each other and adjacent buildings.

n Use non-weathering, corrosion-resis-tant permanent materials.

n Landscape ancillary structures con-sistent with larger structures.

n Integrate the structure with land-scaping, and other site elements.

n Do not use temporary buildings.

n Minimize the use and number of storage buildings, and consolidate in low-visibility areas.

Pavilions n Locate pavilions centrally among sev-eral facilities to create multipurpose use.

n Construct new pavilions with brick columns and low-sloped gable, stand-ing seam dark brown metal roofs at high-visibility locations.

n Use manufactured pavilions in low-visibility locations with ACRB ap-proval only.

n Wood gazebos are not allowed.

Passenger Waiting Shelters n Use brick walls and standing seam metal roofs.

n Provide glazing front and back to al-low for views and wind protection for the user.

n Use brick pavers or scored pavement patterns as accent.

Kiosks n Locate kiosks at high public use ar-eas such as shopping areas, housing areas, and recreation areas.

n Design kiosks with metal roofs, brick, and precast concrete details com-patible with surrounding architecture.

design standards - basewide

SCREENS AND ENCLOSURES

Screens and enclosures help to minimize the visual impact of undesirable features and provide separation and security where necessary. Both architectural and landscape screens – separately and in combination – can be applied to achieve visual continuity throughout the base.

General n Where possible, use landscaping instead of walls for screening.

n Use landscaping to soften walls, fences, and screen dumpsters.

n Locate utility components in the least visible area with adequate access to minimize the need for screening and enclosures.

n Ensure screens are high enough to conceal equipment, vending ma-chines, and utilities.

Walls n Use brick with brick-cap units when adjacent to or within 30 feet of a building to follow base design standards.

n Generally, do not attach screen walls to buildings.

n Do not place screen walls imme-diately adjacent to roadways or sidewalks.

n Walls adjacent to building shall match the material.

n Integral color CMU walls are only al-lowed in flightline/industrial areas.

Fences n Use wrought iron fencing for high visibility sites.

n Use standard brick columns for screening.

n Black vinyl-covered chain link fence in industrial and low-visibility sites is allowed with ACRB approval.

n Perimeter fencing shall respond to the site context and use combi-nations of vinyl-covered chain link, decorative metal, or brick per ACRB direction.

n Wood or white vinyl is allowed only in the Family Housing setting.

Dumpster Enclosures n Locate dumpsters to minimize visual impact; follow base design standards.

n Use brick with a brick cap unit for wall construction.

n In high-visibility locations provide dark brown metal gates to screen dumpsters.

n Provide 6" concrete filled dark brown protective bollards.

n Provide concrete pads and access aprons.

n Include landscaping areas and provi-sions for pedestrian access.

Force Protection n Integrate security walls with the build-ing architecture.

n Use a combination of walls, bollards, and tension cables with landscape beds.

n Minimize the visibility of all force protection devices with landscaping and integral designs.

n Jersey Barriers are allowed only with ACRB approval. Do not paint.

14 15architectural compatibility plan - Fairchild Air Force Base

LANDSCAPING

Use landscaping to enhance facilities and to unify the base. Organize land-scape features to connect individual facilities to walkways, roadways, and open spaces.

Maintenance n Establish a maintenance program.

n Use only approved planting materials as specified on the Landscape Materi-als listing Appendix A3.

n Allow shrubs to mass naturally and avoid ornamental pruning.

n Use shredded softwood or rock mulch with landscaping fabric to in-crease moisture retention and control weed growth.

n Provide sprinkler systems in planting areas.

Edging n Provide concrete edging at planting beds as the standard.

n Raised planting beds constructed of brick may be used in pedestrian areas.

Landscape Screens n Where possible, use landscaping and berming instead of walls for screening.

n Reduce the negative visual impacts of parking areas and unsightly features with landscape screening.

n Use a three-tier landscaped screen that combines ground covers, shrubs, and small trees.

Roadways n Primary roadways use same species, deciduous and coniferous street trees equally spaced to coordinate with light standards.

n Secondary and access roadways use a more random spacing of mixed spe-cies in clusters and / or groupings at focal points.

n Plant street trees on the building side of sidewalks.

design standards - basewide

Parking Areas n Reduce the visual impact of large parking areas with landscape buffers, berming, and parking islands.

n Use street trees in medians and islands to create shade and interest.

n Fill in between trees with low shrubs, flowers, and ground covers. Allow areas for pedestrian cross circulation.

n Use shrubs in groupings around the perimeter of parking areas to soften views from the street.

n Avoid the use of hedges outlining parking areas.

n Use shrubs and landscaped berms to soften the impact of parking areas.

Facility n Use landscaping elements that compliment building architectural features and proportions.

n Provide a soft transition from the horizontal ground plane to the plane of the building.

n Highlight building entries and architectural features and screen unattractive building features such as utility risers or service areas.

n Mix evergreen and deciduous palette of shrubs for seasonal interest.

n Design randomly spaced plant-ings and tree massing to fill areas between facilities.

n Use ground covers within planting beds.

Open Spaces n Use turf for all recreation areas, pa-rade grounds, lawns, and open fields.

n Create undeveloped natural areas using native grasses.

n Incorporate maintenance-free ground cover materials in areas of steep slope or areas that are difficult to maintain.

16 17architectural compatibility plan - Fairchild Air Force Base

WALKWAYS AND PATHS

Develop a consistent pedestrian circula-tion system of walkways and paths to enhance the community. Connect pas-senger waiting shelters, outdoor plazas, parks, and other pedestrian gathering sites into the overall circulation network.

Sidewalks n Provide walkways a minimum of 5 feet wide along all primary, sec-ondary, and access roadways.

n Maintain a minimum 3-foot wide landscaped parkway between curb and sidewalk.

n Provide curvilinear walks for dormi-tory and housing areas.

n Size sidewalks appropriately for the visual scale of the facility and the amount of pedestrian traffic volume.

n Use natural colored concrete with a broom finish and troweled edges.

Crosswalks and Ramps n Ensure that all paths lead to the saf-est crossing point possible, and cross roadways at 90-degree angles.

n Incorporate ADA accessible curb ramps and crosswalk markings into all crosswalks.

n Crosswalks should be designated with striping.

n Construct all concrete curb ramps with a waffle stamp pattern and flared curb ramps.

n Provide for adequate drainage away from the ramp or by drainage grates.

Recreation Trails n Provide a minimum 6-foot paved width in a free form configuration that follows the contours or other natural features.

n Separate the trail system from vehicu-lar traffic by a minimum of 10 feet.

n Take advantage of natural environ-ments such as the natural wildlife area.

n Incorporate activity generators, interpretive signs, and recreation opportunities.

n Provide a 5-foot by 10-foot paved rest area approximately every mile.

Include a bench and litter receptacle at each location.

n Use asphaltic concrete for the trail system. In highly natural settings use compacted, crushed fines.

Plazas and Courtyard Paving n Use standard brick pavers or colored concrete as a unifying theme for plazas and courtyard paving.

n Concrete may be stamped to accent the design.

n Use manufacturer standard patterns for concrete pavers.

n Brick pavers shall be red. Refer to the Appendix for specs.

design standards - basewide

ROADS

Develop the transportation network to provide a consistent experience through-out the base. An organized system of primary, secondary, and tertiary arteries must provide sequential order with each hierarchy of roadway being designed consistently.

Primary n Primary roadways are developed as boulevards and contain two lanes of traffic in each direction often with planted medians.

n Minimize stops and turns, and elimi-nate on-street parking.

n Parking and service access curb cuts are discouraged.

n Keep parking areas and buildings away from the road edge.

Secondary n Secondary roadways are feeder streets from access roads to primary roads.

n On-street parking is discouraged.

n Keep off-street parking areas away from the road edge.

n Minimize the number of curb cuts from driveways and area entrances.

Tertiary n Tertiary roadways are the narrow-est and slowest public streets and provide access to individual sites or parking areas.

n On-street parking and curb-cuts for driveways, parking lot entrances, and services drive entrances are allowed.

n Maintain capability for large vehicles such as fire trucks and moving vans.

Service Drives n Service drives provide access for service vehicles to certain parts of a building or site.

n Combine service drives for several facilities where possible.

n Sidewalks can double as service drives; size and design accordingly.

n Maintain a setback between the building and service drive.

n Minimize the visual impact of service drives through correct placement of drives and landscape screening.

Paving n Use asphalt paving for all primary, secondary, and access roadways.

n Use concrete paving in loading areas, dumpster enclosures, and sites used by heavy vehicles.

n Gravel surfacing may be used on patrol roads and outlying sites only.

n Incorporate a concrete apron where gravel roads meet paved roads.

n All patching shall match adjacent materials.

Curb and Gutter n Comply with base CE standards for all 6-inch integrated concrete curb and gutter for all roadways in developed areas.

n Patrol roads and service drives in outlying areas may not require curb and gutter, with ACRB approval.

n Wheel stops in lieu of curbs are not allowed.

n Do not paint concrete curbs.

18 19architectural compatibility plan - Fairchild Air Force Base

PARKING

Develop functional lots with clear circulation and a positive appearance that complements the facility. Provide a pleasant transition from the parking area to the facility.

General n Reduce large parking areas with land-scaped islands and planting strips.

n Combine parking areas for adjacent facilities.

n Parking layout must address accessi-bility, maintenance, snow removal, and safety issues.

n Avoid parking directly in front of primary building entrances.

n Provide spacing between parking lots and buildings in compliance with force protection standards.

n Avoid parking on roads or within 40 feet of an intersection.

n Use the 90-degree parking configu-ration when possible.

n Provide 4" wide white striping for all pavement markings.

n Do not paint handicapped parking symbols on the asphalt.

Medians and Islands n Provide planting medians for every four rows of vehicles and paver islands for every 20 stalls. Coordinate with snow removal operations.

n Coordinate layout for light poles with the islands and minimize their number to provide the required illumination.

n Provide designated areas for pedes-trian cross traffic.

Reserved Parking n Minimize number of reserved spaces.

n Designate spaces by rank or title with curb-mounted signs.

Paving n Asphalt paving is the standard.

n Use concrete where required for heavy vehicles, motorcycle parking, and where fuel spills may occur.

Curb and Gutter n Use concrete curbs and gutters for parking areas.

n Asphalt curbs, wood timbers, and precast wheel stops are prohibited.

n Do not paint concrete curbs.

design standards - basewide

SIGNS

Signs are an important and positive element in the overall base appearance.

Their purpose is to clearly communicate necessary or helpful information for directions, identification, and customer service without adding visual clutter.

General n Use concise, clear signing in ac-cordance with Air Force, AMC, and Fairchild AFB Sign Standards.

n Minimize the number of signs used for each facility.

n Signs must be consistent in style, placement, color, and language.

n Avoid mottoes, super graphics, or individual titles on buildings or identi-fication signs.

Color n Use dark brown for backgrounds with reflective white lettering on metal placards unless otherwise noted.

n Use dark brown square metal posts.

n Finish back of sign and fastening devices dark brown.

Identification Signs n Limit the use of monument signs to entry gates, headquarters buildings, housing neighborhoods, and special use areas / facilities with ACRB approval.

n Limit the use of mottoes, individual titles, or insignia.

n Incorporate landscaping, accent lighting, and / or paving.

n Facility identification signs with street addresses are generally free standing and not applied to facility facades.

n Display facility numbers in one location - at the back or side corner of buildings, coordinated with architectural features.

n Building-mounted signs or individual letters with corporate logos are al-lowed for commercial facility signs only with ACRB approval.

Direction Signs n Use to identify highly frequented or special interest destinations and street names.

n Display the Air Mobility Command logo decal on the left of all street name signs.

Regulation Signs n Use for traffic control, parking, and base warnings.

n Traffic control signs must follow the Manual on Uniform Traffic Control Devices administered by the Federal Highway Administration for color and display requirements.

n Handicapped parking signs must fol-low AMC Exterior Sign Standards for color and display requirements.

n Base warning signs must adhere to the Air Force Sign Standard for color and display requirements.

20 21architectural compatibility plan - Fairchild Air Force Base

SITE FURNISHINGS

The common use and style of site ameni-ties will further unify the base, provid-ing a recognizable theme of continuity throughout. Reflect the basewide stan-dard regardless of where site furnishings are placed.

General n Select site furnishings from the list on page A1.

n Use the base-standard metal bench.

Seating / Benches n Provide seating along walkways, near building entries, and in courtyards and plazas.

n Place benches within a paved area.

Litter / Ash Receptacles n Place surface-mounted or portable litter and ash receptacles at building entrances, pathways, outdoor seat-ing, and picnic areas.

n Locate these to be functional, yet visually unobtrusive.

Planters n Minimize the use of freestanding planters.

n When used, locate planters in con-junction with other exterior elements.

n Use planters that match ash and litter receptacles in design.

Bike Racks n Provide bicycle-parking areas for all facilities. Combine areas for densely sited buildings.

n Place bike racks on concrete pads in accessible locations near established bike routes and near secondary building entrances.

n Increase the numbers of available bike racks in residential and recreational areas.

n Screen bicycle parking areas with landscaping or screen walls.

n Align bollards at sites having multiple racks.

Barbecue Grills n Limit built-in grills to recreational areas, dormitories, and fire stations.

n Use materials that complement adjacent facilities.

n Placement and design of built-in grills must be approved by the ACRB.

design standards - basewide

Picnic Tables n Use factory finished, recycled plastic picnic tables with metal frames.

n Do not use at administration yard areas or industrial facilities.

n Provide mid-morning to late-after-noon shade for all picnic tables.

n Limit tables to outdoor picnic or dining areas; and group to allow for large parties or individual family outings.

Bollards n Use bollards to protect buildings, equipment, and people from vehicle impact and to restrict access.

n Use a 6-inch diameter, factory fin-ished dark bronze aluminum, domed-top bollard as the standard.

n Use same style bollard with single-function luminaire at pedestrian areas, pathways, and entrances.

n For force protection use a 6-inch diameter, concrete filled, steel pipe.

Cap lighted force protection bollards with a pre-manufactured, domed-top, single luminaire.

n For bollards protecting equipment or buildings from vehicle damage, paint to match adjacent surfaces.

n Use reflective beads in paint on bollards used in auto traffic areas.

Tree Grates n Use natural cast iron tree grates at all formal plazas and courtyards set into concrete paving. Accent with brick pavers.

Playground Equipment n Provide consistent-style pre-manu-factured play equipment at parks, family housing areas, child develop-ment centers, community centers, recreational areas, and TLF's.

n Place equipment with safe ground surfacing, benches, litter receptacles, and landscaping for shade.

n Provide adequate pedestrian circu-lation paths to play areas.

Flag Poles n Use a brushed aluminum pole, mounted on a concrete base.

n Create a sense of place at flag pole locations with landscape or plaza design.

22 23architectural compatibility plan - Fairchild Air Force Base

LIGHTING

Exterior lighting is a system that directly impacts the visual qualities of the base.

By day, the fixtures and poles add visual character and rhythm to the streetscape.

By night these amenities contribute to the perception of safety and comfort.

Use common components throughout the base.

General n Use underground utility service to lighting fixtures.

n Use metal halide lamps for all applications.

n Photometrics are required for all applications.

Streets n All classifications of roadways will use the same luminaries, poles, and mounting height.

n Use clear aluminum poles with co-bra-head luminaries and poles for all roadways.

n Equally space poles on alternating sides of all roadways

Parking Areas n Use arm-mounted, square, shoebox-type luminaries in factory finished dark brown. Use aluminum, round-tapered, dark bronze poles.

n Use multiple luminaries on a single pole to reduce clutter.

n Coordinate pole placement with park-ing island locations.

Walkways and Paths n Provide pedestrian-scaled lighting fixtures throughout housing area and along recreation trails and sidewalks not adjacent to roadways.

n Equally space light fixtures for side-walks on same side of walk.

n Use arm-mounted shoebox fixtures.

Mounting Heights n Control spillover light near residential areas.

n Keep mounting heights low and consistent. Any lights mounted over 30 feet high require special review by the ACRB.

Architectural and Accent n Incorporate recessed, wall-mounted luminaries to wash light across plaza, paving, and stairs.

n Minimize and integrate into the build-ing design the use of building-mount-ed fixtures for general illumination of service yards and outdoor spaces.

n Uplight architectural, landscaping, and building entrance features to emphasize importance and hierarchy.

design standards - basewide

UTILITIES

Use consistent utility components and place electrical services and building feeds underground to reduce overhead visual clutter.

Utility Lines n Place all utility lines underground.

n Do not cut pavements to install utilities.

Utility Structures n Avoid free standing utility structures where possible.

n Use underground vaults for equip-ment where possible.

n Locate pad-mounted equipment in less visible areas and screen with landscaping or screen walls.

Fire Hydrants n Locate fire hydrants at least 5 feet away from other structures. Maintain a 30-inch clear area.

n Paint hydrants Spanish Moss.

Utility Components n Carefully place and organize equip-ment and services.

n Locate mechanical equipment on the least public side of the building.

n Screen mechanical equipment with landscaping materials or screen walls.

n If equipment is placed within 10 feet of a building, paint Spanish Moss unless within 10 feet of a light-colored surface, then match the wall color.

n Minimize the use of all externally at-tached meters and control devices. If used, paint to match the wall color.

n Exterior surface-mounted utility con-duits, lines, or equipment are NOT allowed (except meters and control devices).

n In remote locations, paint freestand-ing pipes and above-ground utility system components Spanish Moss.

Communications n Collocate coaxial and telephone exte-rior components and entry points.

n Align all communication components with one another on the horizontal and vertical plane.

24 25

The flightline encompasses aircraft hangars and maintenance facili-ties. Buildings should be designed with forms, materials, and color palettes similar to those of the Basewide area, but with simplified de-tailing more befitting their function. Large buildings – common to this area – require careful design and orientation to avoid unappealing monolithic facades.

flightline / industrial architectural compatibility plan - Fairchild Air Force Base

BUILDINGS

n Observe all horizontal and vertical safety restrictions along the flightline.

n Consolidate functions where pos-sible to eliminate smaller, individual buildings.

n Integrate large masses and volumes with smaller ones to minimize the scale.

n Only use pavement to buildings when necessary.

n Lower the apparent height of hangars and warehouses by modulating build-ing elevations with submasses, clere-stories, openings, material changes, and architectural detailing.

n Avoid large, flat facades.

n All industrial facilities require curbs and bollard protection.

WALL SYSTEMS

n Use brick or a combination of brick and CMU or metal panels on smaller administrative facilities.

n Do not use metal panels as the sole material for any structure.

n Integral color CMU may be used as a sole material for facilities with ACRB approval.

n Cap brick parapet walls with metal or precast concrete coping.

n On larger facilities use a combination of brick and flat metal panels.

n Use a horizontal expression of metal panels.

n Locate visible vents and louvers as planned design elements; avoid ran-dom placement.

n Vents and louvers are to match the color of adjacent surfaces.

design standards - flightline

ROOF SYSTEMS

n All structures must use hipped or gabled roof forms.

n Low-slope roofs are allowed only for very large volumes or accent sub-masses with ACRB approval.

n Metal roofing for large industrial buildings may be of the minimum slope recommended by the manufacturer.

n Use membrane roofing where mini-mal-slope roofs are permitted with ACRB approval.

n Lower appendages and entries shall have hipped or gabled roofs.

WINDOWS AND DOORS

n Clerestory windows are encouraged to increase natural light and to break up the mass of the facade.

n Windows, doors, and frames must be dark bronze anodized on CMU structures with thermal break construction.

n Primary personnel entrance doors and storefronts with medium style doors shall have full glass panels or glass sidelights.

n Secondary-use doors, such as service and exit-only doors shall match adja-cent wall surfaces.

n Large hangar doors must match the wall color.

LANDSCAPING

n Use landscaping to soften and re-duce the scale of larger facilities.

n Minimize the use of deciduous trees and shrubs to prevent leaf buildup along the apron and runway.

n Reduce the density of landscaping by grouping landscape elements at entries and high-visibility areas.

SCREENS AND ENCLOSURES

n Integrate physical security measures into the architectural design process.

n Coordinate security walls with the design of adjacent facilities or the immediate context.

n Use screen walls and defined road-ways in selected locations to direct and limit facility access.

n Painting of Jersey barriers is prohibited.

26 27

Residential architectural settings should express a neighborhood image that distinguishes them from the remainder of the base.

Achieving architectural compatibility within the setting relies on the use of consistent building materials, site furnishings, and landscaping. Residents are afforded some opportunities to use the standards creatively to express individual pride of place in and around their homes.

family housing architectural compatibility plan - Fairchild Air Force Base

GENERAL

n Organize units into cohesive neigh-borhoods with defined public space along the street. Minimize the use of cul-de-sacs.

n Match the existing styles in housing renovation alteration projects.

n Construct new community facilities following the basewide design standards.

WALL SYSTEMS

n Use trim and brick accents that are compatible with the field colors and that highlight significant building features.

n Alternate exterior color schemes randomly using the paint and siding colors specified on page A1.

ROOF SYSTEMS

n Use roof configuration and color to link the Family Housing setting to the rest of the installation.

n Use gabled or hipped roofs with pitches between 4:12 and 5:12.

n Consider the use of dormers.

n Use shingles with an architectural profile to unify the neighborhood scheme.

n Use fascias, gutters, downspouts, and soffits finished to match the trim.

n Use factory-finished, corrosion resistant materials.

ANCILLARY STRUCTURES

n Use passenger waiting shelters that are sized to accommodate the num-ber of people using them.

n Use the base standards for materials and form.

design standards - family housing

LANDSCAPING

n Use mixed species and informal land-scaping to integrate new with existing housing areas and to improve the overall community setting.

n Add plantings for shade and privacy and develop foundation plantings.

n Use randomly spaced plantings and tree massing.

n Landscape the perimeter edges of recreational and common areas.

n Use landscaped berms to soften major arterial roads and screen undesirable views.

n All self-help landscape materials are to follow the ACRB's approved material list.

n Develop a street tree program.

SCREENS AND ENCLOSURES

n Use wood or white vinyl fencing for privacy in backyards for screening.

n Use vinyl-coated chain link fencing around the base boundary of the housing area.

ROADS

n Enhance streetscapes with landscaping, walkways, and site furnishings.

n Use road features such as smaller radius corners and narrow street widths to reduce traffic speeds.

WALKWAYS AND PATHS

n Emphasize pedestrian and bicycle circulation within housing areas and connect to community facilities.

n Provide seating and other basewide site furnishings along walkways.

n Use concrete paving for patios.

NEIGHBORHOOD ENTRIES

n Construct neighborhood entrance signs reflecting the architectural character of the setting.

n Provide accent landscaping, lighting, and concrete paving.

LIGHTING AND UTILITIES

n Provide pedestrian-scale lighting fixtures throughout housing areas.

n Utility elements such as transformers shall be factory-finished dark brown to blend with surroundings.

28 29architectural compatibility plan - Fairchild Air Force Base

The ACP is a multipurpose tool that shall be used throughout the entire planning, programming, and design process, from inception to project completion for any project on base.

The ACP is implemented by the Base Civil Engineer.

While architectural designers are the primary users of the plan, it must also be used by project managers, pro gram mers, planners, engineers, maintenance and operations personnel, self-help personnel, SABER per-sonnel and the Architectural Compatibility Review Board

(ACRB).

Any items purchased for the exterior of buildings

– including those purchased with impact cards – must conform to the requirements prescribed in the ACP.

In the next three pages, key elements in the implementa-tion process are highlighted.

implementation implementation

Key Elements

Adhering to key elements of the im ple -men ta tion process leads to success in designing excellent facilities that will be compatible with and a part of the whole community.

n Distribute the ACP.

n Establish the Architectural Com pat i -bil i ty Review Board (ACRB).

n Hire good designers.

n Respect the General Plan.

n Process proper submittals.

n Cross-reference all planning and design documents to the ACP.

Distribute the ACP

Distribution of the plan should be as wide as possible. On base, provide cop-ies to commanders of all major units and tenants, the civil engineering squadron commander, operations, branch chiefs, base architect, and community planner.

Provide copies to the major command and headquarters representatives.

Establish the ACRB

The ACRB is the installation approval au-thority for all designs and visual features on the installation.

n The ACRB is organized by the Base Civil Engineer (BCE).

n The chair per son as appointed.

n Members include the base architect, community planner, engineering flight chief, operations flight chief, project manager, and others as deter-mined by the chair per son.

n The base architect, engineering disciplines, and project manager review designs regardless of ACRB involvement.

n The ACRB meets as required.

n Most projects, regardless of size, must be approved by the ACRB. (The chairperson makes the de ter mi na tion on review requirements).

n Design projects are submitted to the ACRB by the base-assigned project manager (see project checklist on page A5 for submittal re quire ments).

ACRB Project Checklist

All projects and service contracts are to be reviewed by the ACRB using the checklist on page A5. The Base project manager is responsible for providing the design checklist to the ACRB for com ple tion.

30 31architectural compatibility plan - Fairchild Air Force Base

Hire Good Designers

Ensure the involvement of design oriented personnel in the A-E selection process.

n Select A-E firms that are sensitive to and understand architectural compatibility.

n The AF project manager provides cop-ies of the ACP to the designer before design begins.

Respect the General Plan

All new projects must agree with the goals and objectives outlined in the in-stallation master plan to ensure that the siting of new projects is compatible with adjacent facilities.

Process Proper Submittals

All architecturally sensitive design projects are reviewed by the ACRB. This includes Requirements Documents, Concept Design, and Final Design submittals.

Submittals shall include the required information and data at the appropri-ate times, and the process shall allow adequate review time.

Requirements Document

In the initial submittal, the A-E defines

– with the help of the AF – the require-ments for the project. It may explore potential solutions, but more importantly, it includes bubble diagrams depicting the relationships of major functional elements and site / facility development options. This submittal is reviewed by the ACRB.

Each submitted package will comprise the following:

n Scope / Programming Requirements n Project Description n Goals and Objectives n Sub-area Development Plans n Site Inventory / Site Analysis n Spatial Relationship Analysis (i.e., relationship to site) n Adjacent Facilities and Project Site Photos

Site Inventory / Site Analysis includes (but is not limited to): vehicular traffic patterns, view, climatic conditions, envi-ronmental, safety, utility constraints, and geographic conditions. Refer to sketch.

implementation

Develop site plans, floor plans, roof plans, and building elevations concur-rently to ensure the proposed solution is a comprehensive design. Floor plans must be developed with consideration of the site and building massing.

The ACRB will review concept submit-tals. If the initial submittal is rejected, or if there are significant concerns or com-ments, a resubmission is required prior to proceeding to the next design stage.

Each submittal package shall include:

n Concise Verbalized Design Concept n Systems Description n Adjacent Facilities and Site Photos n Site Plans (colored) n Floor Plans n Composite Elevations (with color and shadows) n Mechanical / Electrical Communica-tions Entrances and Equipment Locations and Configurations.

n Building Sections n Roof Plan n Massing or Perspective Sketches n Study Model (as required) n Cost Estimate

Final Design

The final design shall remain consistent with the approved concept design. It includes highly developed drawings that further refine and detail the visual and functional quality of the design.

As a minimum, each submittal package shall include the following:

n Formal Colored Rendering (early in this phase) n Material / Color Boards (interior and exterior) n Catalog Cuts (photos) n Design Analysis n Cost Estimate n Contract Documents

Contract Documents (CDs)

Contract documents must be in Auto- CAD and include comprehensive draw-ings and specifications to meet all of the standards defined by the ACP.

All civil, mechanical, and electrical drawings must be consistent with the ar-chitectural drawings. All utility elements such as light fixtures, transformers, panels, grilles, vents, piping, etc., must be shown on the architectural drawings.