Attachment 1a - Line Drawings.pdf
PDF 2 MB Posted
- Attached to
- Uninterruptible Power Supply (UPS) System Install and Maintenance/Sustainment Service – WOSB Set-Aside
- Solicitation number
- FA461324Q1016
About this file
This solicitation requests quotes for an uninterruptible power supply system installation and maintenance services contract. The 90th Contracting Squadron is seeking a contractor to provide all necessary equipment, labor, management and transportation to remove an old UPS system and install a new system at Francis E. Warren Air Force Base in Wyoming. The contractor will also be responsible for maintenance and sustainment services over the potential five-year period of performance. Quotes are due no later than February 29, 2024 and should include pricing for the base year installation as well as fixed monthly rates for maintenance in the base year and four option years. The award will be a fixed-price commercial contract for a Women-Owned Small Business.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M O
TO
R
R
ATED
TO
G
G
LE
S M
30/3/ "30
"3"1 EN
C
LO
SED
C
IR
C
U
IT BR
EAKER
D
EN
O
TES TH
E AM
PER
E R
ATIN
G
D
EN
O
TES TH
E N U
M
BER
O
F PO
LES.
D
EN
O
TES TH
E EN
C
LO
SU
R
E'S N
EM
A R
ATIN
G
C B
ED
EXH
AU
ST D
AM
PER
(SEE M
EC
H
AN
IC
AL)
ID
IN
TAKE D
AM
PER
(SEE M
EC
H
AN
IC
AL)
FAC
FIR
E ALAR
M C
O N
TR
O
L PAN
EL (SEE FIR
E ALAR
M
FAT
FIR
E ALAR
M
TR
AN
SC
EIVER
(SEE FIR
E ALAR
M
D
D C
D
IR
EC
T D
IG
ITAL C
O N
TR
O
L (SEE M
EC
H
AN
IC
AL)
JAC
JAVA APPLIC
ATIO
N
C O
N
TR
O
L EN
G
IN
E (SEE M
EC
H
AN
IC
AL)
SIM
PLEX N
EM
A 5-20R
R
EC
EPTAC
LE. M
H = 18", U
O N
P C
AM
ER
A PO
W
ER
SU
PPLY
30/3/N
F/1 SU
PPLEM
EN
TAL PO
W
ER
LEG
EN
D
"W C
"G
FI"
"TV"
"W P"
M O
TO
R
STAR
TER
"30" "3" "N
F"
"1"
M O
TO
R
R
ATED
TO
G
G
LE SW
ITC
H
JU
N
C
TIO
N
BO
X, W
ALL M
O U
N
TED
. H
EIG
H
T AS IN
D
IC
ATED
M O
TO
R
D
ISC
O N
N
EC
T/SAFETY SW
ITC
H . D
ISC
O
N N
EC
TS SH
ALL
BE R
ATED
"30/3/N
F/1" W H
ER
E LO
C
ATED
IN
D
O O
R
S AN
D
"30/3/N F/3R
" W H
ER
E LO
C
ATED
O U
TD
O
O R
S, U O
I.
D
EN
O
TES TH
E AM
PER
E R
ATIN
G
D
EN
O
TES TH
E N
U M
BER
O
F PO
LES.
D
EN
O
TES N
O N
-FU
SED
("F" D
EN
O
TES FU
SED
; FU
SE
R
ATIN
G
S SH
ALL BE IN
AC
C
O R
D
AN
C E W
ITH
TH
E M
AN
U
FAC
TU
R
ER
'S R
EC
O M
M
EN
D
ATIO
N S).
D
EN
O
TES TH
E EN
C
LO
SU
R E'S N
EM
A R
ATIN
G
D U
PLEX/Q
U
AD
20A R
EC
EPTAC
LE. M
H
= 18", U O
N . R
EC
EPTAC
LES
IN
R
EPAIR
BAYS AN
D
M
AIN
TEN
AN
C
E AR
EAS SH
ALL BE M
O U
N
TED
AT 36", U
N
. SU
BSC
R
IPTS AD
JAC
EN
T TO
R
EC
EPTAC
LES SH
ALL
D
EN
O
TE TH
E FO
LLO
W
IN
G
D
EN
O
TES ELEC
TR
IC
W
ATER
C O
O
LER
(W C
). C O
O R
D
IN
ATE
R
EC
EPTAC
LE M
O
U N
TIN
G
H
EIG
H
T/LO
C
ATIO
N W
ITH
EW
C
IN
STALLER
. PR
O
VID
E G
FC
I C
IR
C U
IT BR
EAKER
S FO
R
C
IR
C U
ITS SER
VIN
G
EW
C R
EC
EPTAC
LES.
D
EN
O
TES G
R O
U N
D
FAU
LT C
IR
C U
IT IN
TER
R U
PTER
(G
FC
I).
D
EN
O
TES FO
R
TELEVISIO
N . C
O O
R D
IN
ATE M
O U
N
TIN
G W
ITH
TV O
U
TLET LO
C
ATIO
N
D
EN
O
TES U
L LISTED
FO
R W
ET LO
C
ATIO
N
& W H
ILE-IN
-U
SE
C
O
VER
. W
EATH
ER
PR
O O
F R
EC
EPTAC
LES SH
ALL ALSO
BE
G
FC
I R
EC
EPTAC
LES.
SPEC
IAL PU
R
PO
SE R
EC
EPTAC
LE.
S
TO
JU
N
C
TIO
N
BO
X, H
EIG
H
T AS IN
D
IC
ATED
J
ABBR
EVIATIO
N
S FO
R
SPEC
IAL PU
R
PO
SE R
EC
EPTAC
LES AN
D
JU
N
C
TIO
N
BO
XES. TAG
S
AD
JAC
EN
T TO
R
EC
EPTAC
LES AN
D
JU
N C
TIO
N
BO
XES SH
ALL D
EN
O
TE TH
E FO
LLO
W
IN
G
R
EC
EPTAC
LE/JU
N C
TIO
N
BO
X D
EFIN
ITIO
N S:
+42" M
O U
N
TIN
G H
EIG
H
T TO
BO
TTO
M
O F R
EC
EPTAC
LE W
H
EN
O
TH
ER
TH
AN
18".
AFI
AR
C
FAU
LT IN
TER
R
U
PTER
R
EC
EPTAC
LE.
G
FC
I G
R O
U N
D
FAU
LT C
IR
C U
IT IN
TER
R U
PTER
R
EC
EPTAC
LE.
IVC
IN
C
ID
EN
T C O
M M
AN
D
VEH
IC
LE R
EC
EPTAC
LE.
U
PS
O R
AN
G
E D U
PLEX, 20A R
EC
EPTAC
LE C
O N
N
EC
TED
TO
U
PS PO
W
ER
W
P W
EATH
ER
-PR
O
O
F EN
C
LO
SU
R
E.
EQ
U
IPM
EN
T D
EFIN
ITIO
N
S:
C
F C
O
FFEE M
AC
H
IN
E
C T
C O
O
K TO
P D
D R
YER
(clothes)
D W
D
ISH
W
ASH
ER
G
D G
AR
BAG
E D
ISPO
SAL
H
D H
AN
D
D R
YER
IC
E
IC
E M
AC
H
IN
E
KC
P
KEYLESS C
O N
TR
O
L PAN
EL
M W
M
IC
R O
W
AVE
O
VEN
D O
U
BLE O
VEN
R
F R
EFR
IG
ER
ATO
R
TV
TELEVISIO
N
W W
ASH
IN
G M
AC
H
IN
E (clothes)
W C
W
ATER
C O
O
LER
EQ
U
IPM
EN
T TAG
S D
EFIN
ITIO
N S:
R
O O
M N
U M
BER
W
H
ER
E EQ
U
IPM
EN
T IS LO
C
ATED
R
O O
M N
U M
BER
W
H
ER
E EQ
U
IPM
EN
T IS LO
C
ATED
-EQ
U
IPM
EN
T N
U M
BER
J
R
EC
ESSED
FLO
O R
R
EC
EPTAC
LE.
U S Arm y C orps of Engineers ® O m aha D istrict
SHEET
US ARMY CORPS OF ENGINEERS
DCBA
MW BUILDING 250
FE WARREN AFB, WYOMING
GHLN 09-1011
EP001 POWER SUPPLIMENTAL LEGEND AND
NOTES
RENOVATE WING COMMAND POST 90,
OMAHA DISTRICT
OMAHA, NEBRASKA
G
EN
ER
AL PO
W
ER
N O
TES:
(APPLIC
ABLE TO
ALL EP SH
EETS)
1.ALL W
IR
IN
G
SH
ALL C
O
M
PLY W
ITH
N
FPA 70-2014, N
ATIO
N
AL ELEC
TR
IC
AL C
O
D E.
2.PR
O
VID
E N
AM
EPLATES O
N
TH
E EXTER
IO
R O
F ALL ELEC
TR
IC
AL PAN
ELS AN
D
EN
C
LO
SU
R
ES AS FO
LLO
W
S: D
EVIC
E ID
D
EVIC
E R
ATIN
G
, AN
D
PO
W
ER
SO
U
R C
E. PR
O
VID
E LABEL IN
D
IC
ATIN
G
"AR
C
FLASH
H
AZAR
D
3.M
IN
IM
U
M
SIZE C
O N
D U
IT W
ILL BE 3/4" FO
R
ELEC
TR
IC
AL C
IR
C U
ITS AN
D
1" C O
N D
U
ITS FO
R
TELEC
O M
M U
N
IC
ATIO
N
S C
IR
C
U
ITS.
4.M
IN
IM
U
M
SIZE PO
W
ER
C O
N D
U C
TO
R
S TO
BE U
SED
SH
ALL BE #12 AW
G
U N
LESS O
TH
ER
W
ISE N
O
TED
. R
EC
EPTAC
LE
C
IR
C
U
ITS SH
ALL BE 2-#12,#12G
M
IN
IM
U M
5.PO
W
ER
SU
PPLIES FO
R
VAV BO
XES SH
ALL FEED
A M
AXIM
U
M O
F 6 VAV BO
XES.
6.M
ETAL C
LAD
(M
C ) C
ABLE APPLIC
ATIO
N
-M C
C
ABLE SH
ALL N
O
T BE U
SED
FO
R
H O
M E R
U N
C
ABLIN
G . H
O M
E R U
N C
ABLIN
G
SH
ALL IN
STALLED
IN
C O
N D
U
IT.
-M C
C
ABLE SH
ALL N
O
T BE U
SED
FO
R
EXPO
SED
C
IR
C U
ITIN
G
. EXPO
SED
C
IR
C U
ITIN
G
SH
ALL IN
STALLED
IN
C O
N D
U
IT.
-M C
C
ABLE SH
ALL N
O
T BE U
SED
IN
D
ED
IC
ATED
R
EC
EPTAC
LE BR
AN
C H
C
IR
C U
ITS (C
IR
C U
ITS W
ITH
O N
LY O
N
E R
EC
EPTAC
LE).
-M
C C
ABLE SH
ALL N
O
T BE U
SED
IN
C
IR
C U
ITS W
ITH
TH
R
EE-PH
ASE LO
AD
S.
-M C
C
ABLE SH
ALL N
O
T BE U
SED
IN
C
IR
C
U
ITS W
ITH
SIN
G
LE-PH
ASE LO
AD
S LISTED
O
N
EP602-EP603.
-M C
C
ABLE SH
ALL N
O
T BE U
SED
IN
FEED
ER
S BETW
EEN
M
C C
'S, PAN
ELBO
AR
D
S, SW
ITC
H
BO
AR
D
S, AN
D
TR
AN
SFO
R
M
ER
S.
-M
C C
ABLE M
AY BE U
SED
IN
LIG
H
TIN
G
BR
AN
C H
C
IR
C U
ITS EXC
EPT AS O
TH
ER
W
ISE PR
O H
IBITED
-M C
C
ABLE M
AY BE U
SED
IN
G
EN
ER
AL R
EC
EPTAC
LE BR
AN
C
H C
IR
C
U
ITS EXC
EPT AS O
TH
ER
W
ISE PR
O
H
IBITED
7.PO
W
ER
/C
O M
M U
N
IC
ATIO
N
S SEPAR
ATIO
N R
EQ
U
IR
EM
EN
TS:
-PR
O
VID
E 2" BETW
EEN
M
C C
ABLE R
U
N N
IN
G
IN
PAR
ALLEL W
ITH
A C O
M M
U N
IC
ATIO
N S W
IR
EW
AY.
-C
R O
SSO
VER
S BETW
EEN
M C
C
ABLES AN
D C
O M
M U
N
IC
ATIO
N
S W
IR
EW
AYS SH
ALL BE PER
PEN
D
IC
U
LAR
TO
EAC
H O
TH
ER
W
ITH
TH
E M
C C
ABLE R
O
U
TED
BELO
W
C O
M M
U N
IC
ATIO
N S W
IR
EW
AY.
8.M O
U N
TIN
G
H
EIG
H
TS SH
ALL BE AS SH
O
W N
IN
EP501 U
N
LESS O
TH
ER
W
ISE N
O
TED
9.M O
U N
T O U
TLET BO
XES SO
TH
AT N
O N
E O C
C U
R R
EC
ESSED
BAC
K TO
BAC
K IN
W
ALLS.
10.M
EC
H
AN
IC
AL EQ
U
IPM
EN
T IS SH
O W
N
IN
APPR
O
XIM
ATE LO
C
ATIO
N
S. FO
R
EXAC
T LO
C
ATIO
N
S O F M
EC
H
AN
IC
AL
EQ
U
IPM
EN
T AN
D
PIPIN
G
, SEE M
EC
H
AN
IC
AL D
R
AW
IN
G
S. PR
O
VID
E D
ISC
O N
N
EC
T SW
ITC
H
ES AS R
EQ
U
IR
ED
BY TH
E
N
ATIO
N
AL ELEC
TR
IC
AL C
O
D
E EVEN
IF N
O
T IN
D
IC
ATED
O N
TH
E ELEC
TR
IC
AL D
R
AW
IN
G S. D
ISC
O
N N
EC
TS AR
E SH
O
W N
AT
O
R O
N A W
ALL N
EAR
AN
TIC
IPATED
EQ
U
IPM
EN
T LO
C
ATIO
N
. LO
C
ATE D
ISC
O
N N
EC
TS IN
AC
C
O R
D
AN
C E W
ITH
N
FPA 70.
PR
O
VID
E LO
C
KABLE D
ISC
O N
N
EC
T W H
ER
E D
IC
TATED
PER
N
FPA 70 AR
TIC
LE 430.102 AN
D
440.14 FO
R
R
EM
O
TE LO
C
ATIO
N S.
10.C O
M
BIN
ATIO
N
D
ISC
O N
N
EC
T SW
ITC
H
ES AN
D M
O
TO
R
STAR
TER
S M
AY BE PR
O
VID
ED
IN
LIEU
O
F PR
O
VID
IN
G
SEPAR
ATE
D
EVIC
ES.
11.C O
N D
U C
TO
R
AN
D
C O
N D
U
IT SIZES AR
E BASED
O
N C
O
PPER
C O
N D
U C
TO
R
S W
ITH
TH
W
N
IN
SU
LATIO
N
IN
EM
T C
O N
D U
IT.
C
IR
C
U
IT BR
EAKER
S, TER
M
IN
ALS, ETC
. SH
ALL BE R
ATED
AN
D
M
AR
KED
FO
R 75 D
EG
R
EES M
IN
IM
U
M
. TH
E C O
N
TR
AC
TO
R
SH
ALL AD
JU
ST C
O
N D
U
IT SIZES BASED
O N
AC
TU
AL TYPE O
F C
O N
D U
C
TO
R
S AN
D C
O N
D U
IT IN
STALLED
12.W H
ER
E C
IR
C
U
IT N
U M
BER
S AR
E SH
O
W N
AD
JAC
EN
T TO
ELEC
TR
IC
AL D
EVIC
ES, W
IR
IN
G
SH
ALL BE IN
AC
C O
R D
AN
C
E W
ITH
TH
E M
AN
U
FAC
TU
R
ER
S R
EC
O
M M
EN
D
ATIO
N
S AN
D
/O R
R
EQ
U
IR
EM
EN
TS.
13.ALL W
IR
IN
G
SH
ALL BE C
O N
C
EALED
U N
LESS EXPLIC
ITLY IN
D
IC
ATED
O
TH
ER
W
ISE. JU
N C
TIO
N
BO
XES, D
EVIC
ES,
BAC
KBO
XES, AN
D
ASSO
C
IATED
C
O N
D U
IT LO
C
ATED
O
N
PR
EC
AST, C
O N
C R
ETE, C
O
N C
R
ETE BLO
C K W
ALLS, AN
D
STEEL
M
EM
BER
S SH
ALL BE SU
R
FAC
E M O
U N
TED
. JU
N C
TIO
N
BO
XES, D
EVIC
ES, BAC
KBO
XES, AN
D
ASSO
C
IATED
C O
N D
U
IT SH
ALL
BE R
EC
ESS M
O U
N
TED
O N
G
YPSU
M W
ALLS.
14.U N
LESS O
TH
ER
W
ISE N
O
TED
, EM
T C O
N D
U
IT SH
ALL BE IN
STALLED
IN
EXPO
SED
D
R
Y AR
EAS W
ITH
SC
R
EW
FITTIN
G S.
C O
N D
U
IT SH
ALL BE IN
STALLED
IN
AC
C O
R D
AN
C
E W
ITH
TH
E SPEC
IFIC
ATIO
N
S. EXPO
SED
O
U
TLET BO
XES SH
ALL BE C
AST
M
ETAL W
ITH
TH
R
EAD
ED
FITTIN
G
S AN
D
C O
VER
S TH
AT FIT FLU
SH
W
ITH
TH
E ED
G
ES O
F TH
E O
U
TLET BO
XES.
15.R
EVISE PAN
ELBO
AR
D
SC
H
ED
U
LES O
N
AS-BU
ILT-D
R
AW
IN
G
AN
D
PAN
EL D
IR
EC
TO
R
IES TO
R
EFLEC
T FIN
AL
IN
STALLATIO
N C
O N
D
ITIO
N S.
16.SEAL PEN
ETR
ATIO
N
S TH
R
O U
G H
FLO
O
R S O
R
FIR
E W
ALLS TO
M
AIN
TAIN
TH
E IN
TEG
R
ITY O
F TH
E FIR
E AN
D
AC
O
U
STIC
R
ATIN
G S O
F TH
E W
ALLS AN
D
FLO
O
R S.
17.C O
M
PO
N
EN
TS W
H
IC
H
C O
N
STITU
TE AN
ELEC
TR
IC
AL SYSTEM
SH
ALL BE FU
LLY C
O M
PATIBLE W
ITH
O N
E AN
O
TH
ER
AN
D
SH
ALL BE APPR
O
VED
BY TH
E VAR
IO
U
S M
AN
U
FAC
TU
R
ER
S FO
R U
SE W
ITH
ALL O
TH
ER
C
O M
PO
N
EN
TS W
ITH
IN
TH
E
SYSTEM
. (O
N
E EXAM
PLE O
F AN
ELEC
TR
IC
AL SYSTEM
IS TH
E BU
ILD
IN
G
LIG
H
TIN
G
SYSTEM
C O
M
PR
ISED
O
F FIXTU
R
ES,
LAM
PS, SW
ITC
H
ES, BALLASTS, O
C C
U
PAN
C
Y SEN
SO
R
S, AN
D
D
IM
M
IN
G
EQ
U
IPM
EN
T).
18.LO
C
ATE ALL R
AC
EW
AYS TO
AVO
ID
IN
TER
FER
EN
C E W
ITH
D
U C
TS, PIPES, M
EC
H
AN
IC
AL EQ
U
IPM
EN
T, D
O O
R S
(IN
C
LU
D
IN
G
O
VER
H
EAD
C O
ILIN
G
D O
O R
S), W
ITH
R
EM
O
VAL O
F C
EILIN
G
TILES, O
R W
ITH
AC
C
ESS TO
EQ
U
IPM
EN
T W H
IC
H
R
EQ
U
IR
ES PER
IO
D
IC
AD
JU
STM
EN
T O R
M
AIN
TEN
AN
C E.
19.FO
R
D
ISC
O N
N
EC
T SW
ITC
H
AN
D M
O
TO
R
STAR
TER
LABELS, TH
E TO
P LIN
E SH
ALL BE TH
E N
AM
E/D
ESIG
N
ATIO
N O
F TH
E
EQ
U
IPM
EN
T BEIN
G
FED
BY TH
E SW
ITC
H
/STAR
TER
20.PR
O
VID
E SEPAR
ATE N
EU
TR
ALS FO
R
EAC
H C
IR
C
U
IT U
TILIZIN
G
A N
EU
TR
AL C
O N
D U
C
TO
R (D
O N
O T C
O M
BIN
E
N
EU
TR
ALS).
21.TH
E IN
TER
R
U
PTIN
G R
ATIN
G
O
F TH
E PAN
ELBO
AR
D
S AN
D
ELEC
TR
IC
AL EQ
U
IPM
EN
T SH
ALL BE IN
C
R
EASED
TO
TH
E N
EXT
AVAILABLE R
ATIN
G W
H
ER
E TH
ER
E IS N
O
T A R
ATIN
G
TH
AT IS EQ
U
AL TO
TH
E EQ
U
IPM
EN
TS LISTED
SH
O R
T C
IR
C U
IT
R
ATIN
G
22.PR
O
VID
E G
R O
U N
D
IN
G C
O N
D U
C
TO
R
S IN
ALL C
O
N D
U
ITS. ALL R
AC
EW
AYS SH
ALL H
AVE A SEPAR
ATE EQ
U
IPM
EN
T
G R
O U
N D
IN
G
/BO
N
D
IN
G C
O N
D U
C
TO
R . R
AC
EW
AY SH
ALL N
O
T BE U
SE AS TH
E SO
LE G
R
O U
N D
IN
G
/BO
N
D
IN
G
PATH
23.R
AC
EW
AYS C
R O
SSIN
G
STR
U
C
TU
R
AL EXPAN
SIO
N
JO
IN
TS O
R
SEISM
IC
JO
IN
TS SH
ALL BE PR
O
VID
ED
W
ITH
SU
ITABLE
EXPAN
SIO
N
FITTIN
G
S O R
O
TH
ER
SU
ITABLE M
EAN
S TO
C
O M
PEN
SATE FO
R
TH
E BU
ILD
IN
G
EXPAN
SIO
N
AN
D C
O N
TR
AC
TIO
N
AN
D
TO
PR
O
VID
E FO
R
C O
N
TIN
U
ITY O
F G R
O U
N D
IN
G
24.R
EC
EPTAC
LES TH
AT H
AVE G
FC
I PR
O
TEC
TIO
N
AR
E TO
BE W
IR
ED
SU
C H
TH
AT TH
E LO
SS O
F PO
W
ER
O
N O
N E
R
EC
EPTAC
LE D
O
ES N
O
T AFFEC
T D O
W N
STR
EAM
R
EC
EPTAC
LES.
25.TELEC
O
M R
AC
K D
ED
IC
ATED
PO
W
ER
O U
TLETS SH
ALL BE M
O U
N
TED
TO
R
AC
KS IN
LO
W
ER
LEFT AS FAC
IN
G
TH
E R
EAR
O
F R
AC
K.
26.EAC
H
PU
LL R
O
PE SH
ALL BE LABELED
W
ITH
A U
N
IQ
U
E ID
EN
TIFIER
TAG
G
ED
O
N
EAC
H
EN
D
. TH
E U
SER
EN
D
O
F TH
E
PU
LL R
O
PE SH
ALL ALSO
IN
D
IC
ATE TH
E SO
U
R C
E LO
C
ATIO
N
AN
D
VIC
E VER
SA.
G
EN
ER
AL PO
W
ER
N O
TES C
O
N
TIN
U
ED
(APPLIC
ABLE TO
ALL EP SH
EETS)
27.D O
N O
T PEN
ETR
ATE STR
U
C
TU
R
AL C
O
LU
M N
S, BEAM
S, AN
D
TR
U
SSES. ATTAC
H D
EVIC
ES AN
D R
AC
EW
AY W
ITH
BEAM
C
-C
LAM
PS, BR
AC
KETS, C
LIPS, U
N
ISTR
U
T, AN
D O
TH
ER
N O
N
-PEN
ETR
ATIN
G
AN
D N
O N
- AD
H
ESIVE H
AR
D W
AR
E.
28 C O
O R
D
IN
ATE PO
W
ER
R
EC
EPTAC
LES W
ITH
TELEC
O
M M
U N
IC
ATIO
N S O
U
TLETS. SPAC
IN
G
SH
ALL BE N
G R
EATER
TH
AN
12" C
EN
TER
TO
C
EN
TER
29.C O
N D
U
IT AN
D C
O N
D U
C
TO
R
SIZES LISTED
AR
E M
IN
IM
U M
SIZES. C
IR
C U
ITS M
AY BE C
O M
BIN
ED
IN
TO
C O
M M
O N
C O
N D
U
IT. C
O N
TR
AC
TO
R
IS R
ESPO
N
SIBLE FO
R R
ESIZIN
G
C O
N D
U
ITS PER
N
FPA 70 FILL R
ATIO
R
EQ
U
IR
EM
EN
TS.
30.LIN
E VO
LTAG
E AN
D
LO
W
VO
LTAG
E W
IR
IN
G
SH
ALL BE PR
O
VID
ED
IN
SEPAR
ATE C
O
N D
U
ITS/R
AC
EW
AYS.
31.M
EC
H
AN
IC
AL SYSTEM
C O
IL VALVES, AC
TU
ATO
R
S, AN
D
D
AM
PER
S AR
E PO
W
ER
ED
BY 24VD
C
FR
O
M
TH
E D D
C
SYSTEM
. R
EFER
EN
C
E SC
H
ED
U
LES, SC
H
EM
ATIC
S, AN
D
N O
TES O
N
M
-703 AN
D M
-704. SH
O
U
LD
TH
E C
O N
TR
AC
TO
R
D
EVIATE FR
O M
TH
IS D
ESIG
N
BASIS AN
D
PR
O
VID
E C
O N
TR
O
LS R
EQ
U
IR
IN
G
AD
D
ITIO
N
AL 120VAC
LO
C
AL SU
PPLY IN
LIEU
O
F 24VD
C
FR
O M
A D D
C
PAN
EL, TH
E PO
W
ER
C
IR
C U
ITS SH
ALL BE PR
O
VID
ED
AT N
O
AD
D
ITIO
N
AL C
O
ST TO
TH
E G
O
VER
N M
EN
T. TH
E SO
U
R C
E FO
R
SU
C
H C
IR
C
U
ITS SH
ALL BE FR
O
M
TH
E C
LO
SEST "M
L" PAN
EL W
ITH
AVAILABLE SPAR
E BR
EAKER
S.
32.C O
O R
D
IN
ATE FIN
AL ELEC
TR
IC
AL C
O
N N
EC
TIO
N S, C
O N
D U
C
TO
R S, R
AC
EW
AY, C
IR
C U
IT BR
EAKER
, AN
D
D
ISC
O N
N
EC
TIN
G
D
EVIC
ES AN
D
SIZES W
ITH
M
AN
U
FAC
TU
R
ER
R
EC
O
M M
EN
D
ATIO
N
S FO
R
AC
TU
AL EQ
U
IPM
EN
T
PR
O
VID
ED
. TH
ESE PR
O
PER
TIES H
AVE BEEN
C
O O
R D
IN
ATED
FO
R
EQ
U
IPM
EN
T SH
O
W N
BY O
TH
ER
D
ISC
IPLIN
ES
IN
C
LU
D
ED
IN
TH
IS C
O
N
TR
AC
T SET. TH
E C O
N
TR
AC
TO
R
IS R
ESPO
N
SIBLE FO
R
AD
JU
STIN
G
ELEC
TR
IC
AL
C O
N N
EC
TIO
N
S AN
D D
ISC
O
N N
EC
TIN
G D
EVIC
ES FO
R
EQ
U
IPM
EN
T VAR
IATIO
N
S D
EVIATIN
G
FR
O M
TH
ESE PLAN
S.
33.W
IR
E AN
D
C O
N D
U
IT IS BASED
O N
TH
H
N
/TH
W N
- 2 C O
PPER
C
O N
D U
C
TO
R S W
ITH
75°C
AM
PAC
ITIES, EXC
EPT 60°C
AM
PAC
ITIES W
ER
E U
SED
FO
R
#1 AN
D
SM
ALLER
MARK DESCRIPTION DATE
Attachment 1a - Line Drawings
FA461324Q1016
U P
J
EO
C CHIEF
B07
UNISEX
B06
STO
RAG
E B08
L1-21
4' 0" AFF
L1-41
7' 0" AFF
L1-41
4' 0" AFF
L1-43
7' 0" AFF
L1-43
VAV-02
VAV-01
VAV
EW
H
-2
4' 0" AFF
L1-47
7' 0" AFF
L1-47
O
PEN O
FFICE
B00
L1-13
4' 0" AFF
L1-45
7' 0" AFF
L1-45
4' 0" AFF
L1-49
7' 0" AFF
L1-49
4' AFF
G
FC
I
L1-20
L1-17
L1-16
L1-11
L1-10
L1-15 L1-14 L1-12
U S Arm y C orps of Engineers ® O m aha D istrict
SHEET
US ARMY CORPS OF ENGINEERS
DCBA
MW BUILDING 250
FE WARREN AFB, WYOMING
GHLN 09-1011
EP101 POWER FLOOR PLAN AREA A
RENOVATE WING COMMAND POST 90,
OMAHA DISTRICT
OMAHA, NEBRASKA
3/16" = 1'-0"
EP101
PO
W
ER
FLO
O
R
PLAN
AR
EA A
AR
EA "A"
KEYPLAN-BASEM
EN
T FLO
O
R
PLAN
N
O R
TH
4'
8' 12'
MARK DESCRIPTION DATE
G B
GB
ENTRAPM
ENT
AREA
B01
G
UARD
SHACK
B02
EA CELL
B04 M
AIN CO
M
M B13
STO
RAG
E B12
KITCHENETTE
B10
CO
M
M B09
UPS
B11
G
FC
I
L1-22
L1-23
L1-42
L1-26
L1-30 L1-29
L1-25
L1H
L1-32
FITNESS
B20
SUPERINTENDENT
& C2 O
PS
O
FFICE
B23
CP CHIEF
O
FFICE
B22
CO
RRIDO
R
CO
R-1
TRAINING
B21
O
FFICE
B21A
W O
M
EN
B19
NCO
IC CP
O
PS
B18
JANITO
R
B16
STO
RAG
E B15
M
EN
B17
4' 0" AFF
L1-39
7' 0" AFF
L1-39
4' 0" AFF
L1-41
VAV-04
VAV-05
VAV-06
AH
U
-1
ER
U
-1
U H
-1
EF-1
M U
-1
T-3
M D
P-3
EW
H
-1
D X-2
D X-1
R C
FC
-09
L1-27
L1-28
M
ECHANICAL
M
ECH-1 STAIRS
ST-2
FC
-10
EXISTIN
G
G R
O U
N D
IN
G
C
ABIN
ET:
IN
STALL N
EW
1/0 BAR
E C
PPER
C
N
D U
C
TO
R
BETW
EEN
O U
N D
IN
G
C
ABIN
ETS
L1-5 L1-56
L1-54
L1-52
N
EW
G R
O U
N D
BAR
: C
O N
N
EC
T
TO
EXISTIN
G
G R
O U
N D
IN
SYSTEM
W
ITH
1/0 C O
N D
U C
TO
R
L1-18
L1-6
D X-3
M U
-2
L1
L1-7
G
LO
BAL
ASNT.
ANTENNA
EQ
UIP. RM
B03
O
PEN O
FFICE
B00
CO
NFERENCE
RO
O M
B05
FC
-08
L1-31
G
FC
I G
FC
I
4' AFF
G
FC
4' AFF
G
FC
I
G
FC
I
L1-19
L1-9
P-1
L1-58
L1-60
L1-62
U S Arm y C orps of Engineers ® O m aha D istrict
SHEET
US ARMY CORPS OF ENGINEERS
DCBA
MW BUILDING 250
FE WARREN AFB, WYOMING
GHLN 09-1011
EP102 POWER FLOOR PLAN AREA B
RENOVATE WING COMMAND POST 90,
OMAHA DISTRICT
OMAHA, NEBRASKA
3/16" = 1'-0"
EP102
PO
W
ER
FLO
O
R
PLAN
AR
EA B
AR
EA "B"
KEYPLAN-BASEM
EN
T FLO
O
R
PLAN
N
O R
TH
4'
8' 12'
O R
IG
IN
AL PAN
ELS, R
EC
EPTAC
LES AN
O
U N
D
IN
G
EQ
U
IPM
EN
T AR
E TO
R
EM
AIN
PLAC
E AN
D
FU
N C
TIO
N
AL D
U
R
IN
G C
O N
STR
U
C
TIO
N
ALL C
O
M M
U N
IC
ATIO
N S R
EC
EPTAC
LES,
EQ
U
IPM
EN
T, C
ABLES, C
ABLE TR
AY TO
R
EM
AIN
PLAC
E AN
D
FU
N C
TIO
N
AL D
U
R
IN
G C
O N
STR
U
C
TIO
N
ECHANICAL
M
ECH-2
CO
RRIDO
R
L1-51
L1-38
L1-33
L1-36
CRISIS
ACTIO
N
TEAM
B24
CM
DR
O
FFICE
B25
7' 0" AFF
L1-44
4' 0" AFF
L1-44
7' 0" AFF
L1-44
4' 0" AFF
L1-46
7' 0" AFF
L1-46
4' 0" AFF
L1-46 7' 0" AFF
L1-48
4' 0" AFF
L1-48
7' 0" AFF
L1-50
4' 0" AFF
L1-50
ER
U
-2
FC
-07
FC
-06
FC
-02
FC
FC
-03
L1-34
EXISTIN
G
G R
O U
N D
IN
G
C
ABIN
ET:
IN
STALL N
EW
1/0 BAR
E C
PPER
N
D U
C
TO
R
BETW
EEN
O U
N D
IN
G
C
ABIN
ETS
L1-35
FC
-04
FC
-05
L1-37 L1-40
P-2
U S Arm y C orps of Engineers ® O m aha D istrict
SHEET
US ARMY CORPS OF ENGINEERS
DCBA
MW BUILDING 250
FE WARREN AFB, WYOMING
GHLN 09-1011
EP103 POWER FLOOR PLAN AREA C
RENOVATE WING COMMAND POST 90,
OMAHA DISTRICT
OMAHA, NEBRASKA
3/16" = 1'-0"
EP103
PO
W
ER
FLO
O
R
PLAN
AR
EA C
AR
EA "C
KEYPLAN-BASEM
EN
T FLO
O
R
PLAN
N
O R
TH
4'
8' 12'
ILLW
O R
K W
/ BAC
KSPLASH
R
EC
EPTAC
LE
R
EC
EPTAC
LE
D
ATA C
ABLE O
U
TLET
SEE
AR
C H
ITEC
TU
R
AL
M
ILLW
O R
K ELEV.
C
ABIN
ET
6"
M
ILLW
O R
K W /O
BAC
KSPLASH
D
ATA C
ABLE O
U
TLET
3"
LIG
H
T SW
ITC
H
LIG
H
T SW
ITC
H
BAC
KSPLASH
4'-0"
6'-0"
W
ALL TELEPH
O N
E
TELEPH
O
N E/D
ATA,
O
R
TV O
U
TLET
M
AN
U
AL FIR
E
ALAR
M
PU
LL
STATIO
N
D
EVIC
ES SH
O
W N
AT C
O
U N
TER
S
W
ITH
O U
T M
ILLW
O R
K BELO
W
M O
U N
TED
AT TH
IS ELEVATIO
N
D U
PLEX
ELEC
O
U
TLET
SIN
G
LE G
AN
G W
ALL SW
ITC
H
18"
FIR
M U
LTI-G
AN
G W
ALL
SW
ITC
H
& D
IM
M
ER
FAC
EPLATE
I
FIR
E ALAR
M
VISU
AL
FIR
E ALAR
M
AU
D
IO
/VISU
AL
RE F
FIR
E
SPEAKER
VO
LU
M
E C
O N
TR
O
L
IN
TER
C
O M
STATIO
N
TV PO
ER
EC
EPTAC
LE
AN
D
D
ATA O
U
TLET
(SPAC
E 0'-6" APAR
T)
N O
TES:
1. TH
ESE M
O
U N
TIN
G
H
EIG
H
TS APPLY U
N
LESS SPEC
IFIED
O
R N
O
TED
O
TH
ER
W
ISE O
N
D R
AW
IN
G S.
2. AD
JU
ST M
O
U N
TIN
G
H
EIG
H
TS IN
C M
U C
O N
STR
U
C
TIO
N
AS R
EQ
U
IR
ED
TO
AVO
ID
C
U
TTIN
G M
O R
E TH
AN
O N
E BLO
C
K.
3. C
O O
R D
IN
ATE D
EVIC
E LO
C
ATIO
N S W
ITH
M
ILLW
O
R
K AN
D O
W N
ER
4. O U
TLET D
EVIC
ES SH
ALL N
O
T BE IN
STALLED
BAC
K TO
BAC
K, A 6" M
IN
IM
U
M O
FFSET.
SEC
U
R
ITY AC
C
ESS
C
AR
D R
EAD
ER
ALIG
N
W
ITH
C
EN
TER
LIN
E O
F D
O O
R
FO
R W
ALL
M
O U
N
TIN
GFIN
ISH
ED
FLO
O R
8"
6'-8"
4'-6"
U S Arm y C orps of Engineers ® O m aha D istrict
SHEET
US ARMY CORPS OF ENGINEERS
DCBA
MW BUILDING 250
FE WARREN AFB, WYOMING
GHLN 09-1011
EP501 MOUNTING HEIGHT DETAIL
RENOVATE WING COMMAND POST 90,
OMAHA DISTRICT
OMAHA, NEBRASKA
LIG
H
T SW
ITC
H
L11-24
PAN
EL PO
SITIO
N
N U
M
BER
PAN
EL D
ESIG
N
ATIO
N
ELEC
TR
IC
AL R
EC
EPTAC
LE
C O
VER
LABELS
ALL C
O
VER
S SH
ALL BE PR
O
VID
E W
ITH
AN
ID
EN
TIFIER
. TH
E PO
W
ER
D
EVIC
E
C O
VER
LABELIN
G M
U
ST BE D
O N
E IAW
TH
E FO
LLO
W
IN
G G
U
ID
ELIN
ES:
1. R
EC
EPTAC
LES AN
D
SW
ITC
H
ES SH
ALL BE ID
EN
TIFIED
W
ITH
TH
E PAN
EL AN
PO
SITIO
N
O
F TH
E C
IR
C U
IT BR
EAKER
U
SED
TO
SH
U T O
FF PO
W
ER
TO
TH
E
D
EVIC
E.
2. O U
TLET BO
XES U
SED
FO
R C
IR
C
U
IT EXTEN
SIO
N
TO
SYSTEM
S FU
R
N
ITU
R E
SH
ALL H
AVE ALL C
IR
C U
ITS W
ITH
IN
TH
E BO
X LISTED
O N
TH
E C
O
VER
3. SW
ITC
H
ES, O
C C
U
PAN
C
Y SEN
SO
R
S, AN
D
D
AYLIG
H
TIN
G C
O N
TR
LS, IN
M M
O N
SPAC
ES H
AVIN
G
D
EVIC
ES O
N
D
IFFER
EN
T SW
ITC
H
LEG
S, IN
C
LU
D E
TH
E SW
ITC
H
LEG
D
ESIG
N
ATIO
N
4. W H
ER
E ITEM
3 APPLIES: O
C
C U
PAN
C
Y SEN
SO
R
S AN
D D
AYLIG
H
TIN
N
TR
O
L D
EVIC
ES SH
ALL H
AVE A LABEL PLAC
ED
O N
TH
E AD
JAC
EN
T C
EILIN
O N
TH
E EXPO
SED
BO
X W H
EN
N
O
T PLAC
ED
IN
A C
EILIN
G
H 11-14a
H 11-14a SW
ITC
H
LEG
O N
FINISHED FLO
O
R
9"
12"
G R
O U
N D
W
IR
E TO
ETAL C
O N
D
ITS IN
O M
G R
O U
N D
W
IR
E TO
EXPO
SED
BU
ILD
LU
M N
IN
R
O
IF PR
ESEN
T.
STAN
D
-O
FF
IN
SU
LATO
R
M O
U
TED
TO
ALL. TYPIC
AL
FO
R
TW
O
LO
C
ATIO
N
S.
C O
PPER
G
B SIZE: 4"
H
IG
H
BY 1/4" TH
IC
K BY
24" LO
N G
M
IN
IM
U
M
G R
O U
N D
W
IR
E
EXISTIN
O U
N D
SYSTEM
ETAIL 1 N
O
TES:
1. SEE EG
601 FO
R G
R O
U N
D C
O N
D U
C
TO
R
SIZES.
2. PR
O
VID
E TW
O -H
O
LE BO
LTED
C
O N
N
EC
TO
R
S W
ITH
G R
O U
N D
ATED
BELLEVILLE W
ASH
ER
S BETW
EEN
BU
S AN
D C
O N
N
EC
TO
R
. PR
O
VID
E
C O
N D
U C
TIVE G
R
EASE BETW
EEN
BU
S AN
D C
O N
N
EC
TIO
N
S. PR
O
VID
E
FU
LL W
R
AP STR
AP C
O
N N
EC
TO
R S. C
LAM
PIN
G O
F TH
E STR
APS SH
ALL
BE W
ITH
FU
LL SU
R
FAC
E C
LAM
PIN
G
TO
O
L TO
IN
SU
E EVEN
M
PR
ESSIO
N
AR
O
U N
D
TH
E C
ABLE.
SEE D
ETAIL N
O
TE 2
1. G R
O U
N D
C O
N D
U C
TO
R
SIZES AR
E ID
EN
TIFIED
AS M
IN
IM
U
M
S. PR
O
VID
E
AC
TU
AL C
ABLE SIZE BASED
O
N
AC
TU
AL C
ABLE R
O
U
TIN
G
AN
D
AN
SI
J-STD
-607A STAN
D
AR
D
S IF LAR
G
ER
2. ALL G
R
O U
N D
C
ABLES SH
ALL BE LABELED
AT BO
TH
EN
D S.
3. ALL G
R
O U
N D
IN
G
C O
N D
U C
TO
R
S AR
E N
O
T SH
O W
N
. SEE PLAN
S AN
D
SPEC
IFIC
ATIO
N
S FO
R
AD
D
ITIO
N
AL G
R
O U
N D
IN
G
C O
N D
U C
TO
R
S O R
R
EQ
U
IR
EM
EN
TS.
4. PR
O
VID
E EXO
TH
ER
M
IC
W
ELD
C O
N N
EC
TIO
N
S AN
D
BO
LTED
LU
G C
O N
N
EC
TIO
N
S AT G
R
O U
N D
BAR
S AS PER
SPEC
IFIC
ATIO
N
S.
G
EN
ER
AL D
ETAIL N
O
TES
G R
O U
N D
W
IR
E TO
EQ
U
IPM
EN
T
STAN
D
-O
FF IN
SU
LATO
R M
O U
N
TED
TO
W
ALL
G R
O U
N D
W
IR
E TO
EQ
U
IPM
EN
T
1/4" TH
IC
K BY 24"
LO
N G
C O
PPER
G
R O
U N
D
BU
S
W
ALL
SU
PPO
R
T BR
AC
KET
U S Arm y C orps of Engineers ® O m aha D istrict
SHEET
US ARMY CORPS OF ENGINEERS
DCBA
MW BUILDING 250
FE WARREN AFB, WYOMING
GHLN 09-1011
EP502 ELECTRICAL DETAILS
RENOVATE WING COMMAND POST 90,
OMAHA DISTRICT
OMAHA, NEBRASKA
N
TS
EP502
EXISTIN
G
G R
O U
N D
IN
G
C
ABIN
ET
N
TS
EP502
D
EVIC
E AN
D
O U
TLET LABELS
MARK DESCRIPTION DATE
N
TS
EP502
G R
O U
N D
BAR
D
ETAIL
N
TS
EP502
G
R O
U N
D
BAR
SID
E VIEW
O
TE: PO
W
ER
TR
AN
SFO
R M
ER
SC
H
ED
U
LE
D O
ES N
O
T C O
VER
D
R
IVE ISO
LATIO
TR
SFO
R M
ER
S.
O A = O
IL TO
AIR
IN
SU
LATED
D
T = IM
PLIES D
R
Y TYPE TR
AN
SFO
R M
ER
TR
AN
SFO
R
PR
IM
AR
Y / SEC
O N
D
AR
Y
SIZE
(KVA)
D
ESIG
N
ATO
R
D
TYPE
480 -208Y/120
VO
LT
PH
ASE
M O
U N
TIN
G
PAD
M
O U
N
TED
, EXISTIN
G
-TO
BE R
EM
O
VED
400AT
3P 100A
3P 40A
3P 175A
M D
P-3 (EXISTIN
G
) 277/480 VO
LT 3 PH
ASE 225A
T1
3P 30A
SPAC
E
3P 40A
FR
O
M
PAN
EL
ED
P
3P 15A
SPAC
E
T1 T2
AIR
C
O
LLED
C O
N D
EN
SER
(AAC
-D
1) EXISTIN
G
D
480 -208Y/120
PAD
M
O U
N
TED
, EXISTIN
G
-TO
BE
R
EM
O
VED
T2
3P 225A3P
225A
EN
C
LO
SED
C
IR
C
U
IT BR
EAKER
(EXISTIN
G
U
PS C
ABIN
IT (EXISTIN
G
H
L1
100A 225A
T3
D
480 -208Y/120
PAD
T3
FEED
ER
SC
H
ED
U
LE
G R
O U
N D
N
D U
C
TO
R
4 -#1
C O
N D
U C
TO
R
N U
M
BER
-SIZE
FEED
IR
C U
IT R
ATIN
#8 1 1/2"
C O
N D
U
IT SIZE
N O
TE
110N G
3 -#1
N /A
1 1/2" 110A
4 -#2/0
#6 2"
175N G
175N G
110N G
110A
R
EM
O
VE EXISTIN
TR
SFO
R
M
ER
S, FEED
ER
S AN
D
BR
EAKER
S
U S Arm y C orps of Engineers ® O m aha D istrict
SHEET
US ARMY CORPS OF ENGINEERS
DCBA
MW BUILDING 250
FE WARREN AFB, WYOMING
GHLN 09-1011
EP601 ONE-LINE DIAGRAM
RENOVATE WING COMMAND POST 90,
OMAHA DISTRICT
OMAHA, NEBRASKA
S Arm y C orps of Engineers ® O m aha D istrict
SHEET
US ARMY CORPS OF ENGINEERS
DCBA
MW BUILDING 250
FE WARREN AFB, WYOMING
GHLN 09-1011
EP602 PANEL SCHEDULES
RENOVATE WING COMMAND POST 90,
OMAHA DISTRICT
OMAHA, NEBRASKA
Notes:
Spare
13200 VA
50.00%
6600 VA
H
VAC
1330 VA
90.00%
1197 VA
Total Est. Dem and Current:
51 A
P Pow er
12000 VA
100.00%
12000 VA
Total Conn. Current:
54 A
LM
Largest M otor
11650 VA
125.00%
14563 VA
Total Est. Dem and:
42301 VA
L Lighting
5740 VA
125.00%
7175 VA
Total Conn. Load:
44775 VA
H H
VAC
3466 VA
90.00%
3119 VA
Load Classification Connected Load
Dem and Factor
Estim ated Dem and Panel Totals
Legend:
Total Am ps:
54 A
55 A 53 A
Total Load:
14846 VA
15174 VA
14764 VA
SPAR
E
20 A
2200 VA
0 VA
SPAC
E O N
LY
SPAR
E
20 A
2200 VA
0 VA
SPAC
E O N
LY
SPAR
E
20 A
2200 VA
0 VA
SPAC
E O N
LY
4000 VA
2200 VA
20 A
SPAR
E
4000 VA
2200 VA
20 A
SPAR
E
EW
H -1
P...
20 A
4000 VA
2200 VA
20 A
SPAR
E
ER
U
-2 H
20 A
665 VA
1785 VA
20 A L...
B20, B23, B24, B25, B26 LIG
H
TIN
G
ER
U
-1 H
20 A
665 VA
2195 VA
20 A L...
B01, B02, B03, B04, B05, B06 LIG
H
TIN
G
P-2 H
20 A
900 VA
1761 VA
20 A L...
B01 B02 B10 B12 B14 B15 B16 B17 B18 B19 C O
R -1...
950 VA
3883 VA
950 VA
3883 VA
EF-1
H
20 A
950 VA
3883 VA
20 A L...
P-1
C...
LO
AD
LT
CB
P
A B
C P
CB
LT
LO
AD
C...
Notes:
Enclosure:
Type 1 Sections:
M
CB Rating:
100 A
M ounting:
Surface W ires:
Fram e Rating:
400 A Supply From
M
D P-3
Phases:
M ains Type:
M C
B Location:
M
EC
H
AN
IC
AL M
EC
H
-1 Volts:
480/277 W ye
Fault Duty (M in.):
10 KAIC
Branch Panel:H1
Notes:
Total Est. Dem and Current:
123 A Spare
11000 VA
50.00%
5500 VA
Total Conn. Current:
189 A R
R eceptacle
44320 VA
61.28%
27160 VA
Total Est. Dem and:
44478 VA
P Pow er
4100 VA
100.00%
4100 VA
Total Conn. Load:
67995 VA
H
H
VAC
8576 VA
90.00%
7718 VA
Load Classification
Connected Load Dem and Factor Estim ated Dem and
Panel Totals
Legend:
Total Am ps:
182 A
188 A 199 A
Total Load:
21790 VA
22465 VA
23740 VA
SPAC
E O N
LY
0 VA
0 VA
SPAC
E O N
LY
SPAC
E O N
LY
0 VA
0 VA
SPAC
E O N
LY
SPAC
E O N
LY
0 VA
0 VA
SPAC
E O N
LY
SPAR
E
20 A
1000 VA
0 VA
SPAC
E O N
LY
SPAR
E
20 A
1000 VA
0 VA
SPAC
E O N
LY
SPAR
E
20 A
1000 VA
0 VA
SPAC
E O N
LY
SPAR
E
20 A
1000 VA
1000 VA
20 A
SPAR
E
SPAR
E
20 A
1000 VA
1000 VA
20 A
SPAR
E
SPAR
E
20 A
1000 VA
1000 VA
20 A
SPAR
E
SPAR
E
20 A
1000 VA
250 VA
20 A
P...
R
C P-1
SPAR
E
20 A
1000 VA
100 VA
20 A H
U
H -1
FC
-06, FC
-08, FC
-09, FC
-10 H
20 A
293 VA
1920 VA
20 A R
R
R eceptacle
FC
-01, FC
-02, FC
-03, FC
-04, FC
-05
H
20 A
350 VA
1920 VA
20 A
R
R R eceptacle
VAV-4, VAV-5, VAV-6, VAV-7
P...
20 A
200 VA
1920 VA
20 A R
R
R eceptacle
VAV-1, VAV-2, VAV-3
P...
20 A
150 VA
1920 VA
20 A
R
PEP R
eceptacle
EW
H
-2 P...
40 A
3500 VA
1920 VA
20 A
R
BC
P R eceptacle
B26 R eceptacle R
20 A
800 VA
1920 VA
20 A R
KSR
R eceptacle
B00 M onitor R eceptacle R
20 A
400 VA
400 VA
20 A R
B24 M onitor R eceptacle
B00 M onitor R eceptacle R
20 A
400 VA
400 VA
20 A R
B24 M onitor R eceptacle
B00 M onitor R eceptacle R
20 A
400 VA
600 VA
20 A R
B24 M onitor R eceptacle
B00 M onitor R eceptacle R
20 A
400 VA
600 VA
20 A R
B24 M onitor R eceptacle
B00 M onitor R eceptacle R
20 A
400 VA
1000 VA
20 A R
B24 R eceptacle
B00 M onitor R eceptacle
R
20 A
400 VA
800 VA
20 A
R
B24 R eceptacle
B24 R eceptacle
R
20 A
800 VA
800 VA
20 A
R
B24 R eceptacle
B24 R eceptacle
R
20 A
800 VA
800 VA
20 A
R
B24 R eceptacle
B24 R eceptacle
R
20 A
800 VA
800 VA
20 A
R
B24 R eceptacle
B23 R eceptacle
R
20 A
600 VA
1000 VA
20 A
R
B24 R eceptacle
B21, B21A R eceptacle
R
20 A
1200 VA
600 VA
20 A
R
B22 R eceptacle
B20 R eceptacles
R
20 A
400 VA
400 VA
20 A
R
B20 R eceptacles
B18 R eceptacle
R
20 A
800 VA
400 VA
20 A
R
B20 R eceptacle
C O
R 1, B15, B16 R eceptacle R
20 A
1200 VA
1000 VA
20 A R
B17, B19 R eceptacles
B07 R eceptacle R
20 A
600 VA
800 VA
20 A R
B12, B13 R eceptacle
B05 R eceptacle R
20 A
1200 VA
200 VA
20 A R
B06 R eceptacle
B00, B08 R eceptacle R
20 A
600 VA
800 VA
20 A R
B00 R eceptacle
B00 R eceptacle R
20 A
800 VA
800 VA
20 A R
B00 R eceptacle
B00 R eceptacle R
20 A
600 VA
800 VA
20 A R
B00 R eceptacle
B00 R eceptacle R
20 A
800 VA
800 VA
20 A R
B00 R eceptacle
B00 R eceptacles R
20 A
1200 VA
800 VA
20 A R
B00 R eceptacle
B00 R eceptacle R
20 A
800 VA
800 VA
20 A R
B00 R eceptacle
B00 R eceptacle R
20 A
600 VA
400 VA
20 A R
B00 R eceptacle
2650 VA
1275 VA
M
U -1, D
X-1, D X-2
H
25 A
2650 VA
1275 VA
20 A
H
M U
-2, D X-3
CKT
LO
AD
LT
CB
P A
B C
P
CB
LT
LO
AD
CKT
Notes:
Enclosure:
Type 1 Sections:
M
CB Rating:
175 A
M ounting:
Surface W ires:
Fram e Rating:
225 A Supply From
T-3
Phases:
M ains Type:
M C
B Location:
M
EC
H
AN
IC
AL M
EC
H
-1 Volts:
208Y/120 Fault Duty (M in.):
10 KAIC
Branch Panel:L1
S Arm y C orps of Engineers ® O m aha D istrict
SHEET
US ARMY CORPS OF ENGINEERS
DCBA
MW BUILDING 250
FE WARREN AFB, WYOMING
GHLN 09-1011
EP603 MECHANICAL EQUIPMENT ELECTRICAL
CONNECTION SCHEDULE
RENOVATE WING COMMAND POST 90,
OMAHA DISTRICT
OMAHA, NEBRASKA
M
EC
H
AN
IC
AL EQ
U
IPM
EN
T - ELEC
TR
IC
AL C
O
N N
EC
TIO
N
SC
H
ED
U
LE
E.Q . I.D
. TAG
PAN
EL
C
KT. N
U
M
VO
LT
S
PH
H P
FLA
M
C A
PKG
U
N
IT
N
EM
A
EN
C L.
D
ISC
O N
N
EC
T D
ISC
O
N N
EC
T
STAR
TER
O C
R
ATIN
G
SU
PPLY C
IR
C U
IT
R
EM
AR
KS
TYPE
SIZE
FU
SE
TYPE
SIZE
AH
U -1
M D
P-3 2,4,6
480 V
5.5 hp
8.2 A
10 A Yes
SPST
20 A 3 #12, #12G
, 3/4"C D
X-1 L1
1,3 208 V
0.13 hp
0.8 A
1 A
Yes
SPST
20 A
3 #12, #12G , 3/4"C
D
X-1 SH
ALL BE PO
W
ER
ED
FR
O
M M
U -1
D X-2
L1 1,3
208 V
0.13 hp
0.8 A
1 A Yes
SPST
20 A 2 #12, #12G
, 3/4"C D
X-2 SH
ALL BE PO
W
ER
ED
FR
O M
M U
-1 D
X-3 L1
2,4 208 V
0.13 hp
0.8 A
1 A
Yes
SPST
20 A
2 #12, #12G , 3/4"C
D
X-3 SH
ALL BE PO
W
ER
ED
FR
O
M M
U -2
EF-1
H
1,3,5
480 V
2 hp
3.4 A
5 A Yes
SPST
20 A 2 #12, #12G
, 3/4"C
ER
U -1
H
277 V
0.75 hp
2.4 A
5 A
Yes
SPST
20 A
3 #12, #12G , 3/4"C
ER
U
-2 H
277 V
0.75 hp
2.4 A
5 A Yes
SPST
20 A 2 #12, #12G
, 3/4"C
FC
-01 L1
120 V
0.22 hp
3.1 A
4 A
Yes
SPST
20 A
2 #12, #12G , 3/4"C
FC
-02
L1
120 V
0.22 hp
3.1 A
4 A Yes
SPST
20 A 2 #12, #12G
, 3/4"C
FC
-03 L1
120 V
0.22 hp
3.1 A
4 A
Yes
SPST
20 A
2 #12, #12G , 3/4"C
FC
-04
L1
120 V
0.22 hp
3.1 A
4 A Yes
SPST
20 A 2 #12, #12G
, 3/4"C
FC
-05 L1
120 V
0.22 hp
3.1 A
4 A
Yes
SPST
20 A
2 #12, #12G , 3/4"C
FC
-06
L1
120 V
0.22 hp
3.1 A
4 A Yes
SPST
20 A 2 #12, #12G
, 3/4"C
FC
-07 L1
120 V
0.22 hp
3.1 A
4 A
Yes
SPST
20 A
2 #12, #12G , 3/4"C
FC
-08
L1
120 V
0.22 hp
3.1 A
4 A Yes
SPST
20 A 2 #12, #12G
, 3/4"C
FC
-09 L1
120 V
0.22 hp
3.1 A
4 A
Yes
SPST
20 A
2 #12, #12G , 3/4"C
FC
-10
L1
120 V
0.22 hp
3.1 A
4 A Yes
SPST
20 A 2 #12, #12G
, 3/4"C M
U -1
L1 1,3
208 V
2 hp 21 A
25 A Yes
SPST
25 A 2 #10, #10G
, 3/4"C M
U -2
L1 2,4
208 V
2 hp 21 A
25 A Yes
SPST
25 A 2 #10, #10G
, 3/4"C P-1
H
2,4,6 480 V
10 hp
14 A 18 A
Yes
SPST
30 A
20 A 3 #12, #12G
, 3/4"C P-2
H
277 V
0.75 hp
3.2 A
4 A
Yes
SPST
20 A
2 #12, #12G , 3/4"C
U H
-1 L1
120 V
0.13 hp
0.8 A
1 A
Yes
SPST
20 A
2 #12, #12G , 3/4"C
30 A N
/A 30 A
N /A
N /A
30 A N
/A 30 A
N /A
30 A N
/A 30 A
N /A
30 A N
/A 30 A
N /A
30 A N
/A 30 A
N /A
30 A N
/A 30 A
N /A
30 A N
/A 30 A
N /A
30 A N
/A 30 A
N /A
30 A N
/A 30 A
N /A
30 A N
/A
MARK DESCRIPTION DATE
30 A N
/A
30 A
/A
| Pages from FE98 - BLDG 250 - CONTRACT AWARD DRAWINGS_Redacted |
| UPS Install 2004_Redacted |
File details come from the government source that posted it. Updated .