This document is a set of architectural drawings for the repair and renovation of the interior and exterior of Building 13322, a dormitory facility at Vandenberg Space Force Base.

The project scope includes comprehensive repairs and upgrades to the first and second floors of the dormitory, with work organized around typical residential modules containing bedrooms, bathrooms, kitchens, laundry areas, and common spaces. Specific product and material requirements include: installation of electronic key card systems compatible with existing infrastructure at exterior swinging doors and interior bedroom doors; 36" x 34" shower bases with textured bottoms and chrome 42 Series Parisa fixtures; Cadet Flowise right-height 1.28 GPF toilets; Rise and Shine solid plastic closed front vanities with undercounter-mounted sinks; American Standard Ovalyn undercounter sinks (Model 0495.300) and Price Pfister 42 Series Parisa faucets (Model J42-AMFC); KitchenAid ceramic glass electric ranges (Model KECC056RBL) with Kenmore Elite convection microhood oven combinations (Model 86013); American Standard kitchen sinks (Model 7504.000) with American Standard Arch single control faucets (Model 4101.350); Basco frameless shower enclosures (Series 135S Infinity) with tempered glass and rain-pattern finish; and full-width mirrors above vanities. Construction requirements specify 3 5/8" metal studs with R-19 sound insulation, 5/8" gypsum board, 6" x 24" continuous shafts for bathroom venting and plumbing, sprinkler fire protection systems compliant with NFPA requirements, and compliance with UFC standards for antiterrorism, energy conservation, HVAC systems, and mold prevention. All work must adhere to Air Force standards and design criteria as specified in the referenced technical documents.

View the file

Other files

File Type Posted
B13121_FLRPLAN.pdf PDF
B13122_FLRPLAN.pdf PDF
B13135_FLRPLAN.pdf PDF
B13321_B13323_FLRPLAN.pdf PDF
Aerial View.pdf PDF
B13120_B13121_FLRPLAN.pdf PDF
B13123_FLRPLAN.pdf PDF
B13320_FLRPLAN.pdf PDF
Combo RFQ_UH WiFi_v4.pdf PDF
UHWiFi_RFI.pdf PDF
VSFB Dorm Addresses.pdf PDF
B13321_FLRPLAN.pdf PDF
B13323_FLRPLAN.pdf PDF
Combo RFQ_UH WiFi_v3.pdf PDF
Combo RFQ_UH WiFi_v2.pdf PDF
Atch01_SOW DORM WIFI 27 MAY 20261.pdf PDF
Atch03_SCA WD 2015-5647 Rev 28_17Aug2026.pdf PDF
Atch04_Clauses and Provisions.pdf PDF
Combo RFQ_UH WiFi.pdf PDF
Atch02_PricingSheet.xlsx XLSX spreadsheet
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D A

TE

D

ES

C

RI

PT

IO

N

O F

RE

V

IS

IO

N

SY

M

BO

L

PROJECT #

SHEET #

DRAWING #

D A

TE

OF

SC

A

LE

D

RA

W

IN

G T

ITL

E

PR

O

JE

C

T

TIT

LE

D

RA

W

N

RE

V

IE

W

ED

D

ES

IG

N

ED

F O

R

O

F F

I C

I A

L

U

S E

O

N L

Y

I N

F O

R M

A T

I O

N

S

A F

E G

U A

R D

I N

G

I

R

Q

U I R

T h e i n f o r m a t i o n c o n t a i n d o t h i s d r a w i n g s h a l l r e m a u d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r f n c t i o n a t a l l t i m e s f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a t a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n g l e a s e d i s c l o s u r d a y p a r t y b e y o e o r i g i n a l r e q u e s t a t e n d p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e

U p o n c o m p l e t i o n o f t h e u t h e d a c n t a i n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n d e s t r o y e r e c t a n y q u e s t i o n s e

E n g i n e e r i n g

S u p p o r t

E l e m e n t

C

E S

C

E C

B a t

I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r

A

F M

A N

A

F I

D a x e c u t i v d e r w h e n a p p l i c a b l e

D O

N O

T D

U

PL

IC

A

TE

T

H

IS

D R

A W

IN

G

O

R T

H E

D A

TA

C

O N

TA

IN

ED

O

N

IT

09-1249B / B1

A-101

M

A Y

A

S N

O

TE

D

KR

G

RE

PA

IR

IN

TE

RI

O R/

EX

TE

RI

O

R O

F D

O

RM

, B

LD

G

FI

RS

T

S

EC

O N

D F

LO

O

R

PL

A N

, B

LD

G

TY

PI

C A

L M

O D

UL

E

FL

O

O R

PL

A

N

REFERENCE NOTES 15KEY PLAN 65

13323

13321

0 13

SCALE: NOT TO SCALE

NORTH

PROJECT

TYPICAL MODULE FLOOR PLAN

SCALE: 1/4" = 1'-0"

BEDROOM

207B

164.7 SF

BEDROOM

207C

164.7 SF

KITCHEN

LA

UN

D

RY

CLOSET

BATH BATH

BATH BATH

CLOSET CLOSET

CLOSET

D

C

A

B

C

A

B

BB

C

C C

C

C C

CARPET / VINYL

CARPET / VINYL

VINYL / CARPET

VINYL / CARPET

V

IN

YL

C A

RP

ET

V

IN

YL

C A

RP

ET

C A

RP

ET

V

IN

YL

VINYL / CARPET

CARPET / VINYL

C A

RP

ET

V

IN

YL

50'-8" (TYPICAL MODULE)

4" 3'-1 1/2" 5'-6" 4'-0 1/2" 12'-4" 12'-4"

7' -4

" T

YP

IC

A

L M

O D

UL

E

'-8

" T

YP

IC

A

L M

O D

UL

E

'-2

/2

5'

-3

/4

4' -1

/4

2'

-1

4' -0

4' -0

7'

-1

1/ 2"

3' -4

/2

" 3'-8" 3'-1 1/2" 9'-9 1/2"

1'-0"

3'-6 1/2"

3' -0

/2

3'

-2

/2

1' -9

4'-1 1/2"

1'-0"

6' -4

/2

BEDROOM

106A

169.4 SF

BEDROOM

106B

164.7 SF

BEDROOM

106D

169.4 SF

BEDROOM

106C

164.7 SF

BEDROOM

107A

169.4 SF

BEDROOM

107B

164.7 SF

BEDROOM

107D

169.4 SF

BEDROOM

107C

164.7 SF

BEDROOM

108A

169.4 SF

BEDROOM

108B

164.7 SF

BEDROOM

108D

169.4 SF

BEDROOM

108C

164.7 SF

BATH

BATH

BATH

BATH

KITCHEN

CLOSETCLOSET

CLOSET CLOSET

PATIO

LAUNDRY

BATH

BATH

BATH

BATH

KITCHEN

CLOSETCLOSET

CLOSET CLOSET

PATIO

LAUNDRY

BATH

BATH

BATH

BATH

KITCHEN

CLOSETCLOSET

CLOSET CLOSET

PATIO

LAUNDRY

BATH

BATH

BATH

BATH

KITCHEN

CLOSETCLOSET

CLOSET CLOSET

PATIO

LAUNDRY

BATH

BATH

BATH

BATH

KITCHEN

CLOSETCLOSET

CLOSET CLOSET

PATIO

LAUNDRY

BATH

BATH

BATH

BATH

KITCHEN

CLOSETCLOSET

CLOSET CLOSET

PATIO

LAUNDRY

BEDROOM

206A

169.4 SF

BEDROOM

206B

164.7 SF

BEDROOM

206D

169.4 SF

BEDROOM

206C

164.7 SF

BEDROOM

207A

169.4 SF

BEDROOM

207B

164.7 SF

BEDROOM

207D

169.4 SF

BEDROOM

207C

164.7 SF

BEDROOM

208A

169.4 SF

BEDROOM

208B

164.7 SF

BEDROOM

208D

169.4 SF

BEDROOM

208C

164.7 SF

FIRST FLOOR PLAN, BLDG 13322

SCALE: 1/8" = 1'-0" 54 SECOND FLOOR PLAN, BLDG 13322

SCALE: 1/8" = 1'-0" 44

NORTH

PROJECT

NORTH

TRUE

NORTH

PROJECT

NORTH

TRUE

NORTH

PROJECT

NO

RT

H

TR

UE

1. PAINT AND REINSTALL AS NEEDED REFURBISHED METAL HANDRAILS, GUARDRAILS

AND METAL COLUMNS TYPICAL.

2. PATCH AND PAINT ALL EXTERIOR PLASTER SURFACES ON (E) STAIRS.

3. 5/8" GYPSUM BOARD ON 7/8" FURRING HAT CHANNELS AT ALL (E) CONCRETE

MASONRY WALLS TYPICAL.

4. 36" x 48" FIBERGLASS SHOWER PAN WITH CERAMIC TILE SURROUND; SHOWER

CURB TO BE A MINIMUM OF 4" TYPICAL; PROVIDE A HEAVY-DUTY HAND-HELD

SHOWERHEAD CONNECTED TO A FLEXIBLE HOSE THAT FITS INTO AN ADJUSTABLE

HEIGHT HOLDER MOUNTED ON A VERTICAL ROD.

4.1. AMERICAN STANDARD ACRYLUX 48" x 34" SHOWER BASE, TEXTURED BOTTOM, WHITE

4.2. PRICE PFISTER 16 SERIES HANDHELD SHOWER, CHROME WITH 42 SERIES, PARISA

SHOWER FAUCET, CHROME

5. LOW-FLOW TOILET TO BE AMERICAN STANDARD CADET FLOWISE RIGHT HEIGHT

ELONGATED PRESSURE-ASSISTED TOILET 1.1 GPF TOILET, WHITE

5.1. SEAT: AMERICAN STANDARD 5324.019 RISE AND SHINE SOLID PLASTIC CLOSED

FRONT SEAT WITH COVER

6. 36"w PLASTIC LAMINATE WOOD CABINET w/ UNDERCOUNTER MOUNTED SINK;

COUNTER TOP SHALL BE 30" ABOVE FINISH FLOOR; PROVIDE A MINIMUM OF (2)

8"w x 3"dp DRAWERS WITH REMAINING AREA UNDER THE VANITY AS STORAGE

WITH CABINET DOORS.

7. RECESSED MEDICINE CABINET w/ MIRROR, NOMINALLY 20"w x 26"h x 5"dp

ADJACENT TO VANITY, HINGED NEXT TO MIRROR WITH (3) ADJUSTABLE INTERIOR

SHELVES; KOHLER SINGLE DOOR ALUMINUM CABINET K-CB-CLC2026FS

8. SHELF AND POLE AT +66" AFF ON (2) WALLS AS SHOWN

9. 6" x 36" CONTINUOUS SHAFT FOR DRYER VENTING TYPICAL

10. 6" x 24" CONTINUOUS SHAFT FOR RANGE VENTING TYPICAL

11. 6" x 24" CONTINUOUS SHAFT FOR POWER/COMMUNICATION LINES AS NEEDED

12. 6" x 18" CONTINUOUS SHAFT FOR POWER/COMMUNICATION LINES AS NEEDED

13. COUNTERTOP AT +36" AFF w/ SUPPORTING WALL BELOW TYPICAL

14. WASHER TYPICAL (NIC); PROVIDE HOT/COLD WATER CONNECTIONS, POWER

AND DRAIN LINE

15. DRYER TYPICAL (NIC); PROVIDE GAS LINE, 220v OUTLET AND DRYER VENT IN

SHAFT PROVIDED

16. PROVIDE (2) BURNER ELECTRIC RANGE TYPICAL; KITCHENAID KECC056RBL,

CERAMIC GLASS SURFACE; PROVIDE MICROHOOD CONVECTION OVEN

COMBINATION; KENMORE ELITE 86013;VENT RANGE HOOD TO SHAFT PROVIDED.

17. PROVIDE 54"w PLASTIC LAMINATE WOOD CABINET w/ INSULATED STAINLESS STEEL

SINK TYPICAL; SINK TO BE AMERICAN STANDARD 7504.000 UNDERCOUNTER

MOUNT, STAINLESS STEEL WITH DISPOSAL; FAUCET TO BE AMERICAN STANDARD

4101.350 ARCH SINGLE CONTROL KITCHEN FAUCET WITH PULL-OUT SPRAY.

18. PROVIDE 36"w SPACE FOR REFRIGERATOR (NIC); PROVIDE ELECTRICAL OUTLET

AND WATER CONNECTION FOR ICE MAKER

19. INFILL (E) OPENINGS IN CMU WALL w/ STEEL STUD, INSULATION, EXTERIOR PLASTER ON EXTERIOR FACE AND 5/8" GYPSUM BOARD ON ALL INTERIOR FACES FLUSH w/

FURRED WALL OR ADJACENT INTERIOR WALL

20. TYPICAL INTERIOR WALL CONSTRUCTION SHALL BE 3 5/8" METAL STUDS w/ R-19

SOUND INSULATION AND 5/8" GYPSUM BOARD EACH SIDE

21. 6" x 24" CONTINUOUS SHAFT FOR BATHROOM VENTING AND PLUMBING

22. PROVIDE TEMPERED GLASS SHOWER ENCLOSURE WITH TEMPERED GLASS

SHOWER DOOR (30" MINIMUM CLEAR) WITH INTEGRAL 24"w TOWEL BAR ON

DOOR AS MANUFACTURED BY BASCO SHOWER ENCLOSURES, SERIES 135S

INFINITY, FRAMELESS DOOR, CONTINUOUS HINGE; VERIFY CLEARANCE BETWEEN

DOOR SWING AND TOILET BOWL; GLASS PATTERN SHALL BE "RAIN" OR SIMILAR

FINISH.

23. 14"w x 36"h PLASTIC LAMINATE WOOD CABINET w/ DRAWER, DOOR AND

COUNTERTOP TO MATCH KITCHEN CABINETS.

24. INFILL (E) OPENING IN CMU WALL TO ACCEPT NEW DOOR OR WINDOW.

25. INFILL (E) SHAFT OPENING NOT USED THROUGH EACH FLOOR IN (E) CONCRETE

SLAB TYPICAL

26. (E) PATIO WALLS AND WALKWAYS TO REMAIN TYPICAL; CLEAN, PATCH, REPAIR

AND PAINT TO MATCH; SEE SITE PLAN FOR ADDITIONAL INFORMATION.

27. PROVIDE A FULL WIDTH MIRROR ABOVE THE VANITY, WITH TOP OF MIRROR A

MINIMUM OF 72" ABOVE THE FINISH FLOOR; BOTTOM OF THE MIRROR SHALL

EXTEND TO THE TOP OF THE BACK SPLASH.

28. 36"w OR 42"w PLASTIC LAMINATE WOOD VANITY BASE CABINET w/

UNDERCOUNTER MOUNTED SINK; VERIFY WIDTH WITH LOCATION; COUNTER TOP

SHALL BE 30" ABOVE FINISH FLOOR; PROVIDE A MINIMUM OF (2) 8"w x 3"dp

DRAWERS WITH REMAINING AREA UNDER THE VANITY AS STORAGE ACCESSED BY

CABINET DOORS.

29. PROVIDE FOR INSTALLATION OF ELECTRONIC KEY CARD SYSTEM AT EXTERIOR

SWINGING DOORS AND INTERIOR BEDROOM DOORS TYPICAL; SYSTEM SHALL BE

COMPATIBLE WITH (E) SYSTEM.

30. PROVIDE 18"x60" MIRROR ON THE INSIDE OF THE CLOSET DOOR OR BATHROOM

DOOR AS SHOWN.

31. PROVIDE (2) TOWEL BARS, EACH AT LEAST 24" LONG, WITH (1) INTEGRAL TO

SHOWER DOOR AS NOTED AND THE OTHER AT LOCATION INDICATED TYPICAL.

32. PROVIDE (1) ROBE HOOK ON THE BATHROOM SIDE OF THE BATHROOM DOOR.

33. PROVIDE WALL MOUNTED 30"w x 24"h x 8"dp PLASTIC LAMINATE WOOD

STORAGE CABINET WITH DOORS AND (1) ADJ SHELF OVER THE WAINSCOT OVER

EACH WATER CLOSET TYPICAL; FINISH TO MATCH BATHROOM VANITY CABINET.

34. PROVIDE HEAVY DUTY TOILET TISSUE HOLDER AT SIDE OF BATHROOM VANITY.

35. LAVATORY SINK (UNDERCOUNTER MOUNTED) WITH FAUCET.

35.1. AMERICAN STANDARD OVALYN UNDERCOUNTER SINK 0495.300, WHITE

35.2. PRICE PFISTER, 42 SERIES, PARISA, 4" CENTERSET LAVATORY FAUCET, J42-AMFC,

POLISHED CHROME

36. INSTALL FLOOR MOUNTED DOOR STOPS AS NEEDED TO PREVENT DOORS FROM

DAMAGING ADJACENT SURFACES (GENERALLY IN SAME LOCATIONS AS THOSE

REMOVED).

37. PROVIDE CABINET MOUNTED FIRE EXTINGUISHER UNDER SINK IN APPROPRIATE

LOCATION.

38. PROVIDE INDIVIDUAL THERMOSTATS IN EACH BEDROOM AND COMMON SPACE.

TYPICAL NOTES 14

A. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH REQUIREMENTS AS

OUTLINED IN UFC 4-010-01/02 MINIMUM ANTITERRORISM STANDARDS FOR DOD

BUILDINGS.

B. PROVIDE APPROPRIATE HVAC SYSTEM AS REQUIRED PER THE FOLLOWING:

-- UFC 3-400-01 ENERGY CONSERVATION

-- UFC 3-401-01FA UTILITY MONITORING & CONTROL SYSTEMS

-- UFC 3-410-01FA HVAC

-- ETL 04-3 : DESIGN CRITERIA FOR PREVENTION OF MOLD IN AF FACILITIES

-- UNACCOMPANIED HOUSING GUIDE, US AIR FORCE

C. SEE FINISH, DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION.

D. INSTALL SPRINKLER FIRE PROTECTION SYSTEM THROUGHOUT FACILITY COMPLIANT

WITH NFPA REQUIREMENTS.

E. CONTRACTOR SHALL PATCH AND REPAIR ALL CONCRETE SLABS TO BE

STRUCTURALLY SOUND WHERE (E) UTILITY CHASES ARE REMOVED AND NOT USED.

F. ALL NEW COMMUNICATIONS WIRING, PANELS AND EQUIPMENT TO INCLUDE

TELEVISION CABLE, TELEPHONE, WI-FI WIRING AND ALARM PANEL WIRING SHALL

MEET CURRENT STANDARDS AS DETERMINED BY 30 SPACE COMMUNICATIONS

SQUADRON.

G. ALL INTERIOR WALLS AND INFILL PANELS SHALL CONTAIN A MINIMUM OF R-19

SOUND INSULATION TYPICAL.

DOOR SCHEDULE

SYMBOL SIZE TYPE REMARKS

A 3070 METAL, SOLID CORE 1616 TEMPERED GLAZING, BLAST RESISTANT

B 3070 WOOD, SOLID CORE PAINT GRADE

C 2870 WOOD, SOLID CORE PAINT GRADE

D 8070 TEMPERED GLASS SLIDER (2) FIXED PANELS, (1) SLIDER FIT TO OPENING,

BLAST RESISTANT

WINDOW SCHEDULE

SYMBOL SIZE TYPE REMARKS

1 8046 DUAL GLAZED, SLIDER BLAST RESISTANT

2 5046 DUAL GLAZED, SLIDER FIELD VERIFY SIZE, BLAST RESISTANT

SCHEDULES 24

4 5 31

16 17 18

38 38

38 38

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

A101

NOTE: TYPICAL MODULE FLOOR PLAN ROTATED;

REFER TO OVERALL FLOOR PLAN FOR PROPER

ORIENTATION.

A

TE

D

ES

C

RI

PT

IO

N

O F

RE

V

IS

IO

N

SY

M

BO

L

PROJECT #

SHEET #

DRAWING #

D A

TE

OF

SC

A

LE

D

RA

W

IN

G T

ITL

E

PR

O

JE

C

T

TIT

LE

D

RA

W

N

RE

V

IE

W

ED

D

ES

IG

N

ED

F O

R

O

F F

I C

I A

L

U

L

Y

I N

F O

R M

A T

I O

N

S

A F

E G

U A

R D

I N

G

Q

U I R

T f o r m a t i o n c o n t a i n t h i s d r a w i n g s h a l l r e m a d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r n c t i o n a t a l l t i m e f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n l e a s e d i s c l o s u d a y p a r t y b e y o e o r i g i n a l r e q u e s t a t e n d p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e

U o n c o m p l e t i o n o f t h e u t h e d a c n t a i n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n d e s t r o y e r e c t a n y q u e s t i o n s e

E n g i n e e r i n g

S u p p o r t

E l e m e n t

C

E S

C

E C

B a t

I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r

A

F M

A N

A

F I

D a x e c u t i v d e r w h e n a p p l i c a b l e

D O

N O

T D

U

PL

IC

A

TE

T

H

IS

D R

A W

IN

G

O

R T

H E

D A

TA

C

O N

TA

IN

ED

O

N

IT

09-1249B / B1

A102

M

A Y

A

S N

O

TE

D

KR

G

RE

PA

IR

IN

TE

RI

O R/

EX

TE

RI

O

R O

F D

O

RM

, B

LD

G

FI

RS

T

S

EC

O N

D F

LO

O

R

PL

A N

, B

LD

G

TY

PI

C A

L M

O D

UL

E

FL

O

O R

PL

A

N

THIRD FLOOR PLAN, BLDG 13322

SCALE: 1/8" = 1'-0"

44 ROOF PLAN, BLDG 13322

SCALE: 1/8" = 1'-0"

NORTH

PROJECT

NORTH

TRUE

SEE SHEET A-101, FIRST & SECOND FLOOR PLAN AND TYPICAL

MODULE PLAN FOR ADDITIONAL INFORMATION.

NORTH

PROJECT

NORTH

TRUE

KEY PLAN 65

13323

13321

0 13

SCALE: NOT TO SCALE

NORTH

PROJECT

BATH

BATH

BATH

BATH

KITCHEN

CLOSETCLOSET

CLOSET CLOSET

PATIO

LAUNDRY

BATH

BATH

BATH

BATH

KITCHEN

CLOSETCLOSET

CLOSET CLOSET

PATIO

LAUNDRY

BATH

BATH

BATH

BATH

KITCHEN

CLOSETCLOSET

CLOSET CLOSET

PATIO

LAUNDRY

BEDROOM

306A

169.4 SF

BEDROOM

306B

164.7 SF

BEDROOM

306D

169.4 SF

BEDROOM

306C

164.7 SF

BEDROOM

307A

169.4 SF

BEDROOM

307B

164.7 SF

BEDROOM

307D

169.4 SF

BEDROOM

307C

164.7 SF

BEDROOM

308A

169.4 SF

BEDROOM

308B

164.7 SF

BEDROOM

308D

169.4 SF

BEDROOM

308C

164.7 SF

SLOPE

5:12 TYP.

SLOPE

5:12 TYP.

SLOPE

5:12 TYP

MIN SLOPE

1/4" PER FT TYP

42SCHEMATIC INTERIOR ELEVATIONS

SCALE: 1/4" = 1'-0"

KITCHEN (TYPICAL) LAUNDRY (TYPICAL) BATHROOM - 209A BATHROOM - 209B

(209D SIMILAR) (209C SIMILAR)

12 13 14 15

25 26 27 2728 28 26

31 31

REFERENCE NOTES 35

1. REPLACE AND REPAIR ANY (E) CONCRETE ROOF TILES, SUPPORTING STRUCTURE

(i.e. CLEATS) & BUILDING PAPER AS DISCOVERED DURING DEMOLITION

OPERATIONS. INSPECT PLYWOOD SHEATHING FOR ANY DAMAGE AND/OR NEED

TO REPAIR OR REPLACE. TYPICAL AT ALL CONCRETE TILE ROOF AREAS.

2. INSTALL (N) BUILT-UP ROOF AREA AT ALL AREAS WITH BUILT-UP ROOFING TYPICAL;

INSTALL WITH SLOPES AS SHOWN; PROVIDE 1/4" PER FT SLOPE MINIMUM AND

CRICKETS AS SHOWN.

3. PROVIDE ALL FLASHING AND COUNTER FLASHING AS REQUIRED BY CODE AND

RECOMMENDED BY MANUFACTURER.

4. NOT USED.

5. PROVIDE ALL (N) CONTINUOUS GUTTERS, DOWNSPOUTS, SCUPPERS AND

OVERFLOW SCUPPERS; ALL METALS SHALL BE PRE-FINISHED OR, IF PRE-FINISHED

MATERIAL IS NOT AVAILABLE, PAINTED TO MATCH BUILDING PAINT COLORS.

6. (N) ROOF DRAIN w/ INTEGRAL OVERFLOW INSTALLED AS INDICATED.

7. NOT USED.

8. APPROXIMATE LOCATION OF VENTILATION HOODS FOR VARIOUS SPACES IN

BUILDING; TYPICAL OF (9) SHOWN; ADDITIONAL VENT HOODS MAY BE REQUIRED;

PROVIDE EQUIPMENT COMPLIANT w/ HVAC STANDARDS ON G001.

9. LOUVERED ATTIC VENTILATION OPENING; SIZE TO BE CALCULATED AS REQUIRED

BY INTERNATIONAL BUILDING CODE; TYPICAL OF (14) SHOWN.

10. 30"w x 36"h ATTIC SPACE ACCESS DOOR; TYPICAL OF (3) SHOWN.

11. REPLACE ALL ROOF ACCESS HATCHES WITH SAME SIZE ACCESS DOORS; FIELD

VERIFY QUANTITY AND LOCATION TYPICAL.

12. REFRIGERATOR (NOT IN CONTRACT); PROVIDE 36"w BY 68"h CLEAR SPACE AS

SHOWN.

13. DRAWER BANK TYPICAL; PROVIDE (4) DRAWERS AS SHOWN.

14. PROVIDE CABINET WITH DOORS AND FIXED DRAWER PANEL AT SINK AREA.

15. PROVIDE CABINET WITH DOORS, FIXED DRAWER PANEL AND FIXED SHELF AT

RANGE AREA.

16. PROVIDE SOLID MATERIAL COUNTERTOP (CORIAN OR EQUIVALENT) AT +36" AFF

TYPICAL WITH MINIMUM 4" BACKSPLASH AT ALL COUNTERTOP AREA TYPICAL.

17. PROVIDE MICROHOOD CONVECTION OVEN COMBINATION; KENMORE ELITE

86013;VENT RANGE HOOD TO SHAFT PROVIDED; PROVIDE MINIMUM CLEARANCE

AS REQUIRED BY MANUFACTURER.

18. PROVIDE FULL OVERHEAD CABINET OVER MICROHOOD CONVECTION OVEN

WITH FIXED SHELF AS SHOWN; SIZE ACCORDING TO REQUIRED CLEARANCES AND

MINIMUM DUCT SIZING FOR HOOD.

19. PROVIDE FULL OVERHEAD CABINET WITH FIXED SHELF OVER SINK AREA WITH

BUILT-IN CONCEALED LIGHT FIXTURE UNDER CABINET; PROVIDE MINIMUM

CLEARANCE.

20. PROVIDE FULL OVERHEAD CABINET WITH (2) FIXED SHELVES AS SHOWN TYPICAL;

B.O. OF CABINET AT +18" ABOVE COUNTERTOP TYPICAL.

21. PROVIDE FULL OVERHEAD CABINET AS SHOWN TYPICAL; SIZE SET BY CLEARANCES

REQUIRED BY REFRIGERATOR (SEE NOTE 12).

22. OPEN TO BEYOND.

23. PROVIDE (3) EQUAL CABINETS WITH FIXED SHELF OVER AREA FOR WASHER AND

DRYER; SET BOTTOM OF CABINETS AT MINIMUM OF 68" AFF TYPICAL.

24. PROVIDE CABINET WITH DOOR AND DRAWER AS SHOWN TYPICAL.

25. WASHER AND DRYER (NOT IN CONTRACT); PROVIDE MINIMUM 60" CLEAR AREA

AS SHOWN.

26. 36" x 48" FIBERGLASS SHOWER PAN WITH CERAMIC TILE SURROUND AND

TEMPERED GLASS SHOWER ENCLOSURE; SHOWER CURB TO BE A MINIMUM OF 4"

TYPICAL; SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.

27. DRAWER BANK TYPICAL; PROVIDE (3) DRAWERS AS SHOWN.

28. PROVIDE CABINET WITH DOOR AND FIXED DRAWER PANEL AT SINK AREA.

29. PROVIDE A FULL WIDTH MIRROR ABOVE THE VANITY, WITH TOP OF MIRROR A

MINIMUM OF 72" ABOVE THE FINISH FLOOR; BOTTOM OF THE MIRROR SHALL

EXTEND TO THE TOP OF THE BACK SPLASH.

30. PROVIDE SOLID MATERIAL COUNTERTOP (CORIAN OR EQUIVALENT) AT +30" AFF

TYPICAL WITH MINIMUM 4" BACKSPLASH AT ALL COUNTERTOP AREA TYPICAL.

31. LOW FLOW TOILET TYPICAL; SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.

TYPICAL NOTES 55

A. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH REQUIREMENTS AS

OUTLINED IN UFC 4-010-01/02 MINIMUM ANTITERRORISM STANDARDS FOR DOD

BUILDINGS.

B. PROVIDE APPROPRIATE HVAC SYSTEM AS REQUIRED PER THE FOLLOWING:

-- UFC 3-400-01 ENERGY CONSERVATION

-- UFC 3-401-01FA UTILITY MONITORING & CONTROL SYSTEMS

-- UFC 3-410-01FA HVAC

-- ETL 04-3 : DESIGN CRITERIA FOR PREVENTION OF MOLD IN AF FACILITIES

-- UNACCOMPANIED HOUSING GUIDE, US AIR FORCE

C. SEE FINISH, DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION.

D. INSTALL SPRINKLER FIRE PROTECTION SYSTEM THROUGHOUT FACILITY COMPLIANT

WITH NFPA REQUIREMENTS.

E. CONTRACTOR SHALL PATCH AND REPAIR ALL CONCRETE SLABS TO BE

STRUCTURALLY SOUND WHERE (E) UTILITY CHASES ARE REMOVED AND NOT USED.

F. ALL NEW COMMUNICATIONS WIRING, PANELS AND EQUIPMENT TO INCLUDE

TELEVISION CABLE, TELEPHONE, WI-FI WIRING AND ALARM PANEL WIRING SHALL

MEET CURRENT STANDARDS AS DETERMINED BY 30 SPACE COMMUNICATIONS

SQUADRON.

G. ALL INTERIOR WALLS AND INFILL PANELS SHALL CONTAIN A MINIMUM OF R-19

SOUND INSULATION TYPICAL.

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

File details come from the government source that posted it. Updated .