B13322_FLRPLAN.pdf
PDF 529 KB Posted
- Solicitation number
- FA461026Q0049
About this file
This document is a set of architectural drawings for the repair and renovation of the interior and exterior of Building 13322, a dormitory facility at Vandenberg Space Force Base.
The project scope includes comprehensive repairs and upgrades to the first and second floors of the dormitory, with work organized around typical residential modules containing bedrooms, bathrooms, kitchens, laundry areas, and common spaces. Specific product and material requirements include: installation of electronic key card systems compatible with existing infrastructure at exterior swinging doors and interior bedroom doors; 36" x 34" shower bases with textured bottoms and chrome 42 Series Parisa fixtures; Cadet Flowise right-height 1.28 GPF toilets; Rise and Shine solid plastic closed front vanities with undercounter-mounted sinks; American Standard Ovalyn undercounter sinks (Model 0495.300) and Price Pfister 42 Series Parisa faucets (Model J42-AMFC); KitchenAid ceramic glass electric ranges (Model KECC056RBL) with Kenmore Elite convection microhood oven combinations (Model 86013); American Standard kitchen sinks (Model 7504.000) with American Standard Arch single control faucets (Model 4101.350); Basco frameless shower enclosures (Series 135S Infinity) with tempered glass and rain-pattern finish; and full-width mirrors above vanities. Construction requirements specify 3 5/8" metal studs with R-19 sound insulation, 5/8" gypsum board, 6" x 24" continuous shafts for bathroom venting and plumbing, sprinkler fire protection systems compliant with NFPA requirements, and compliance with UFC standards for antiterrorism, energy conservation, HVAC systems, and mold prevention. All work must adhere to Air Force standards and design criteria as specified in the referenced technical documents.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B13121_FLRPLAN.pdf | ||
| B13122_FLRPLAN.pdf | ||
| B13135_FLRPLAN.pdf | ||
| B13321_B13323_FLRPLAN.pdf | ||
| Aerial View.pdf | ||
| B13120_B13121_FLRPLAN.pdf | ||
| B13123_FLRPLAN.pdf | ||
| B13320_FLRPLAN.pdf | ||
| Combo RFQ_UH WiFi_v4.pdf | ||
| UHWiFi_RFI.pdf | ||
| VSFB Dorm Addresses.pdf | ||
| B13321_FLRPLAN.pdf | ||
| B13323_FLRPLAN.pdf | ||
| Combo RFQ_UH WiFi_v3.pdf | ||
| Combo RFQ_UH WiFi_v2.pdf | ||
| Atch01_SOW DORM WIFI 27 MAY 20261.pdf | ||
| Atch03_SCA WD 2015-5647 Rev 28_17Aug2026.pdf | ||
| Atch04_Clauses and Provisions.pdf | ||
| Combo RFQ_UH WiFi.pdf | ||
| Atch02_PricingSheet.xlsx | XLSX spreadsheet |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D A
TE
D
ES
C
RI
PT
IO
N
O F
RE
V
IS
IO
N
SY
M
BO
L
PROJECT #
SHEET #
DRAWING #
D A
TE
OF
SC
A
LE
D
RA
W
IN
G T
ITL
E
PR
O
JE
C
T
TIT
LE
D
RA
W
N
RE
V
IE
W
ED
D
ES
IG
N
ED
F O
R
O
F F
I C
I A
L
U
S E
O
N L
Y
I N
F O
R M
A T
I O
N
S
A F
E G
U A
R D
I N
G
I
R
Q
U I R
T h e i n f o r m a t i o n c o n t a i n d o t h i s d r a w i n g s h a l l r e m a u d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r f n c t i o n a t a l l t i m e s f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a t a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n g l e a s e d i s c l o s u r d a y p a r t y b e y o e o r i g i n a l r e q u e s t a t e n d p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e
U p o n c o m p l e t i o n o f t h e u t h e d a c n t a i n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n d e s t r o y e r e c t a n y q u e s t i o n s e
E n g i n e e r i n g
S u p p o r t
E l e m e n t
C
E S
C
E C
B a t
I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r
A
F M
A N
A
F I
D a x e c u t i v d e r w h e n a p p l i c a b l e
D O
N O
T D
U
PL
IC
A
TE
T
H
IS
D R
A W
IN
G
O
R T
H E
D A
TA
C
O N
TA
IN
ED
O
N
IT
09-1249B / B1
A-101
M
A Y
A
S N
O
TE
D
KR
G
RE
PA
IR
IN
TE
RI
O R/
EX
TE
RI
O
R O
F D
O
RM
, B
LD
G
FI
RS
T
S
EC
O N
D F
LO
O
R
PL
A N
, B
LD
G
TY
PI
C A
L M
O D
UL
E
FL
O
O R
PL
A
N
REFERENCE NOTES 15KEY PLAN 65
13323
13321
0 13
SCALE: NOT TO SCALE
NORTH
PROJECT
TYPICAL MODULE FLOOR PLAN
SCALE: 1/4" = 1'-0"
BEDROOM
207B
164.7 SF
BEDROOM
207C
164.7 SF
KITCHEN
LA
UN
D
RY
CLOSET
BATH BATH
BATH BATH
CLOSET CLOSET
CLOSET
D
C
A
B
C
A
B
BB
C
C C
C
C C
CARPET / VINYL
CARPET / VINYL
VINYL / CARPET
VINYL / CARPET
V
IN
YL
C A
RP
ET
V
IN
YL
C A
RP
ET
C A
RP
ET
V
IN
YL
VINYL / CARPET
CARPET / VINYL
C A
RP
ET
V
IN
YL
50'-8" (TYPICAL MODULE)
4" 3'-1 1/2" 5'-6" 4'-0 1/2" 12'-4" 12'-4"
7' -4
" T
YP
IC
A
L M
O D
UL
E
'-8
" T
YP
IC
A
L M
O D
UL
E
'-2
/2
5'
-3
/4
4' -1
/4
2'
-1
4' -0
4' -0
7'
-1
1/ 2"
3' -4
/2
" 3'-8" 3'-1 1/2" 9'-9 1/2"
1'-0"
3'-6 1/2"
3' -0
/2
3'
-2
/2
1' -9
4'-1 1/2"
1'-0"
6' -4
/2
BEDROOM
106A
169.4 SF
BEDROOM
106B
164.7 SF
BEDROOM
106D
169.4 SF
BEDROOM
106C
164.7 SF
BEDROOM
107A
169.4 SF
BEDROOM
107B
164.7 SF
BEDROOM
107D
169.4 SF
BEDROOM
107C
164.7 SF
BEDROOM
108A
169.4 SF
BEDROOM
108B
164.7 SF
BEDROOM
108D
169.4 SF
BEDROOM
108C
164.7 SF
BATH
BATH
BATH
BATH
KITCHEN
CLOSETCLOSET
CLOSET CLOSET
PATIO
LAUNDRY
BATH
BATH
BATH
BATH
KITCHEN
CLOSETCLOSET
CLOSET CLOSET
PATIO
LAUNDRY
BATH
BATH
BATH
BATH
KITCHEN
CLOSETCLOSET
CLOSET CLOSET
PATIO
LAUNDRY
BATH
BATH
BATH
BATH
KITCHEN
CLOSETCLOSET
CLOSET CLOSET
PATIO
LAUNDRY
BATH
BATH
BATH
BATH
KITCHEN
CLOSETCLOSET
CLOSET CLOSET
PATIO
LAUNDRY
BATH
BATH
BATH
BATH
KITCHEN
CLOSETCLOSET
CLOSET CLOSET
PATIO
LAUNDRY
BEDROOM
206A
169.4 SF
BEDROOM
206B
164.7 SF
BEDROOM
206D
169.4 SF
BEDROOM
206C
164.7 SF
BEDROOM
207A
169.4 SF
BEDROOM
207B
164.7 SF
BEDROOM
207D
169.4 SF
BEDROOM
207C
164.7 SF
BEDROOM
208A
169.4 SF
BEDROOM
208B
164.7 SF
BEDROOM
208D
169.4 SF
BEDROOM
208C
164.7 SF
FIRST FLOOR PLAN, BLDG 13322
SCALE: 1/8" = 1'-0" 54 SECOND FLOOR PLAN, BLDG 13322
SCALE: 1/8" = 1'-0" 44
NORTH
PROJECT
NORTH
TRUE
NORTH
PROJECT
NORTH
TRUE
NORTH
PROJECT
NO
RT
H
TR
UE
1. PAINT AND REINSTALL AS NEEDED REFURBISHED METAL HANDRAILS, GUARDRAILS
AND METAL COLUMNS TYPICAL.
2. PATCH AND PAINT ALL EXTERIOR PLASTER SURFACES ON (E) STAIRS.
3. 5/8" GYPSUM BOARD ON 7/8" FURRING HAT CHANNELS AT ALL (E) CONCRETE
MASONRY WALLS TYPICAL.
4. 36" x 48" FIBERGLASS SHOWER PAN WITH CERAMIC TILE SURROUND; SHOWER
CURB TO BE A MINIMUM OF 4" TYPICAL; PROVIDE A HEAVY-DUTY HAND-HELD
SHOWERHEAD CONNECTED TO A FLEXIBLE HOSE THAT FITS INTO AN ADJUSTABLE
HEIGHT HOLDER MOUNTED ON A VERTICAL ROD.
4.1. AMERICAN STANDARD ACRYLUX 48" x 34" SHOWER BASE, TEXTURED BOTTOM, WHITE
4.2. PRICE PFISTER 16 SERIES HANDHELD SHOWER, CHROME WITH 42 SERIES, PARISA
SHOWER FAUCET, CHROME
5. LOW-FLOW TOILET TO BE AMERICAN STANDARD CADET FLOWISE RIGHT HEIGHT
ELONGATED PRESSURE-ASSISTED TOILET 1.1 GPF TOILET, WHITE
5.1. SEAT: AMERICAN STANDARD 5324.019 RISE AND SHINE SOLID PLASTIC CLOSED
FRONT SEAT WITH COVER
6. 36"w PLASTIC LAMINATE WOOD CABINET w/ UNDERCOUNTER MOUNTED SINK;
COUNTER TOP SHALL BE 30" ABOVE FINISH FLOOR; PROVIDE A MINIMUM OF (2)
8"w x 3"dp DRAWERS WITH REMAINING AREA UNDER THE VANITY AS STORAGE
WITH CABINET DOORS.
7. RECESSED MEDICINE CABINET w/ MIRROR, NOMINALLY 20"w x 26"h x 5"dp
ADJACENT TO VANITY, HINGED NEXT TO MIRROR WITH (3) ADJUSTABLE INTERIOR
SHELVES; KOHLER SINGLE DOOR ALUMINUM CABINET K-CB-CLC2026FS
8. SHELF AND POLE AT +66" AFF ON (2) WALLS AS SHOWN
9. 6" x 36" CONTINUOUS SHAFT FOR DRYER VENTING TYPICAL
10. 6" x 24" CONTINUOUS SHAFT FOR RANGE VENTING TYPICAL
11. 6" x 24" CONTINUOUS SHAFT FOR POWER/COMMUNICATION LINES AS NEEDED
12. 6" x 18" CONTINUOUS SHAFT FOR POWER/COMMUNICATION LINES AS NEEDED
13. COUNTERTOP AT +36" AFF w/ SUPPORTING WALL BELOW TYPICAL
14. WASHER TYPICAL (NIC); PROVIDE HOT/COLD WATER CONNECTIONS, POWER
AND DRAIN LINE
15. DRYER TYPICAL (NIC); PROVIDE GAS LINE, 220v OUTLET AND DRYER VENT IN
SHAFT PROVIDED
16. PROVIDE (2) BURNER ELECTRIC RANGE TYPICAL; KITCHENAID KECC056RBL,
CERAMIC GLASS SURFACE; PROVIDE MICROHOOD CONVECTION OVEN
COMBINATION; KENMORE ELITE 86013;VENT RANGE HOOD TO SHAFT PROVIDED.
17. PROVIDE 54"w PLASTIC LAMINATE WOOD CABINET w/ INSULATED STAINLESS STEEL
SINK TYPICAL; SINK TO BE AMERICAN STANDARD 7504.000 UNDERCOUNTER
MOUNT, STAINLESS STEEL WITH DISPOSAL; FAUCET TO BE AMERICAN STANDARD
4101.350 ARCH SINGLE CONTROL KITCHEN FAUCET WITH PULL-OUT SPRAY.
18. PROVIDE 36"w SPACE FOR REFRIGERATOR (NIC); PROVIDE ELECTRICAL OUTLET
AND WATER CONNECTION FOR ICE MAKER
19. INFILL (E) OPENINGS IN CMU WALL w/ STEEL STUD, INSULATION, EXTERIOR PLASTER ON EXTERIOR FACE AND 5/8" GYPSUM BOARD ON ALL INTERIOR FACES FLUSH w/
FURRED WALL OR ADJACENT INTERIOR WALL
20. TYPICAL INTERIOR WALL CONSTRUCTION SHALL BE 3 5/8" METAL STUDS w/ R-19
SOUND INSULATION AND 5/8" GYPSUM BOARD EACH SIDE
21. 6" x 24" CONTINUOUS SHAFT FOR BATHROOM VENTING AND PLUMBING
22. PROVIDE TEMPERED GLASS SHOWER ENCLOSURE WITH TEMPERED GLASS
SHOWER DOOR (30" MINIMUM CLEAR) WITH INTEGRAL 24"w TOWEL BAR ON
DOOR AS MANUFACTURED BY BASCO SHOWER ENCLOSURES, SERIES 135S
INFINITY, FRAMELESS DOOR, CONTINUOUS HINGE; VERIFY CLEARANCE BETWEEN
DOOR SWING AND TOILET BOWL; GLASS PATTERN SHALL BE "RAIN" OR SIMILAR
FINISH.
23. 14"w x 36"h PLASTIC LAMINATE WOOD CABINET w/ DRAWER, DOOR AND
COUNTERTOP TO MATCH KITCHEN CABINETS.
24. INFILL (E) OPENING IN CMU WALL TO ACCEPT NEW DOOR OR WINDOW.
25. INFILL (E) SHAFT OPENING NOT USED THROUGH EACH FLOOR IN (E) CONCRETE
SLAB TYPICAL
26. (E) PATIO WALLS AND WALKWAYS TO REMAIN TYPICAL; CLEAN, PATCH, REPAIR
AND PAINT TO MATCH; SEE SITE PLAN FOR ADDITIONAL INFORMATION.
27. PROVIDE A FULL WIDTH MIRROR ABOVE THE VANITY, WITH TOP OF MIRROR A
MINIMUM OF 72" ABOVE THE FINISH FLOOR; BOTTOM OF THE MIRROR SHALL
EXTEND TO THE TOP OF THE BACK SPLASH.
28. 36"w OR 42"w PLASTIC LAMINATE WOOD VANITY BASE CABINET w/
UNDERCOUNTER MOUNTED SINK; VERIFY WIDTH WITH LOCATION; COUNTER TOP
SHALL BE 30" ABOVE FINISH FLOOR; PROVIDE A MINIMUM OF (2) 8"w x 3"dp
DRAWERS WITH REMAINING AREA UNDER THE VANITY AS STORAGE ACCESSED BY
CABINET DOORS.
29. PROVIDE FOR INSTALLATION OF ELECTRONIC KEY CARD SYSTEM AT EXTERIOR
SWINGING DOORS AND INTERIOR BEDROOM DOORS TYPICAL; SYSTEM SHALL BE
COMPATIBLE WITH (E) SYSTEM.
30. PROVIDE 18"x60" MIRROR ON THE INSIDE OF THE CLOSET DOOR OR BATHROOM
DOOR AS SHOWN.
31. PROVIDE (2) TOWEL BARS, EACH AT LEAST 24" LONG, WITH (1) INTEGRAL TO
SHOWER DOOR AS NOTED AND THE OTHER AT LOCATION INDICATED TYPICAL.
32. PROVIDE (1) ROBE HOOK ON THE BATHROOM SIDE OF THE BATHROOM DOOR.
33. PROVIDE WALL MOUNTED 30"w x 24"h x 8"dp PLASTIC LAMINATE WOOD
STORAGE CABINET WITH DOORS AND (1) ADJ SHELF OVER THE WAINSCOT OVER
EACH WATER CLOSET TYPICAL; FINISH TO MATCH BATHROOM VANITY CABINET.
34. PROVIDE HEAVY DUTY TOILET TISSUE HOLDER AT SIDE OF BATHROOM VANITY.
35. LAVATORY SINK (UNDERCOUNTER MOUNTED) WITH FAUCET.
35.1. AMERICAN STANDARD OVALYN UNDERCOUNTER SINK 0495.300, WHITE
35.2. PRICE PFISTER, 42 SERIES, PARISA, 4" CENTERSET LAVATORY FAUCET, J42-AMFC,
POLISHED CHROME
36. INSTALL FLOOR MOUNTED DOOR STOPS AS NEEDED TO PREVENT DOORS FROM
DAMAGING ADJACENT SURFACES (GENERALLY IN SAME LOCATIONS AS THOSE
REMOVED).
37. PROVIDE CABINET MOUNTED FIRE EXTINGUISHER UNDER SINK IN APPROPRIATE
LOCATION.
38. PROVIDE INDIVIDUAL THERMOSTATS IN EACH BEDROOM AND COMMON SPACE.
TYPICAL NOTES 14
A. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH REQUIREMENTS AS
OUTLINED IN UFC 4-010-01/02 MINIMUM ANTITERRORISM STANDARDS FOR DOD
BUILDINGS.
B. PROVIDE APPROPRIATE HVAC SYSTEM AS REQUIRED PER THE FOLLOWING:
-- UFC 3-400-01 ENERGY CONSERVATION
-- UFC 3-401-01FA UTILITY MONITORING & CONTROL SYSTEMS
-- UFC 3-410-01FA HVAC
-- ETL 04-3 : DESIGN CRITERIA FOR PREVENTION OF MOLD IN AF FACILITIES
-- UNACCOMPANIED HOUSING GUIDE, US AIR FORCE
C. SEE FINISH, DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION.
D. INSTALL SPRINKLER FIRE PROTECTION SYSTEM THROUGHOUT FACILITY COMPLIANT
WITH NFPA REQUIREMENTS.
E. CONTRACTOR SHALL PATCH AND REPAIR ALL CONCRETE SLABS TO BE
STRUCTURALLY SOUND WHERE (E) UTILITY CHASES ARE REMOVED AND NOT USED.
F. ALL NEW COMMUNICATIONS WIRING, PANELS AND EQUIPMENT TO INCLUDE
TELEVISION CABLE, TELEPHONE, WI-FI WIRING AND ALARM PANEL WIRING SHALL
MEET CURRENT STANDARDS AS DETERMINED BY 30 SPACE COMMUNICATIONS
SQUADRON.
G. ALL INTERIOR WALLS AND INFILL PANELS SHALL CONTAIN A MINIMUM OF R-19
SOUND INSULATION TYPICAL.
DOOR SCHEDULE
SYMBOL SIZE TYPE REMARKS
A 3070 METAL, SOLID CORE 1616 TEMPERED GLAZING, BLAST RESISTANT
B 3070 WOOD, SOLID CORE PAINT GRADE
C 2870 WOOD, SOLID CORE PAINT GRADE
D 8070 TEMPERED GLASS SLIDER (2) FIXED PANELS, (1) SLIDER FIT TO OPENING,
BLAST RESISTANT
WINDOW SCHEDULE
SYMBOL SIZE TYPE REMARKS
1 8046 DUAL GLAZED, SLIDER BLAST RESISTANT
2 5046 DUAL GLAZED, SLIDER FIELD VERIFY SIZE, BLAST RESISTANT
SCHEDULES 24
4 5 31
16 17 18
38 38
38 38
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
A101
NOTE: TYPICAL MODULE FLOOR PLAN ROTATED;
REFER TO OVERALL FLOOR PLAN FOR PROPER
ORIENTATION.
A
TE
D
ES
C
RI
PT
IO
N
O F
RE
V
IS
IO
N
SY
M
BO
L
PROJECT #
SHEET #
DRAWING #
D A
TE
OF
SC
A
LE
D
RA
W
IN
G T
ITL
E
PR
O
JE
C
T
TIT
LE
D
RA
W
N
RE
V
IE
W
ED
D
ES
IG
N
ED
F O
R
O
F F
I C
I A
L
U
L
Y
I N
F O
R M
A T
I O
N
S
A F
E G
U A
R D
I N
G
Q
U I R
T f o r m a t i o n c o n t a i n t h i s d r a w i n g s h a l l r e m a d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r n c t i o n a t a l l t i m e f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n l e a s e d i s c l o s u d a y p a r t y b e y o e o r i g i n a l r e q u e s t a t e n d p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e
U o n c o m p l e t i o n o f t h e u t h e d a c n t a i n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n d e s t r o y e r e c t a n y q u e s t i o n s e
E n g i n e e r i n g
S u p p o r t
E l e m e n t
C
E S
C
E C
B a t
I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r
A
F M
A N
A
F I
D a x e c u t i v d e r w h e n a p p l i c a b l e
D O
N O
T D
U
PL
IC
A
TE
T
H
IS
D R
A W
IN
G
O
R T
H E
D A
TA
C
O N
TA
IN
ED
O
N
IT
09-1249B / B1
A102
M
A Y
A
S N
O
TE
D
KR
G
RE
PA
IR
IN
TE
RI
O R/
EX
TE
RI
O
R O
F D
O
RM
, B
LD
G
FI
RS
T
S
EC
O N
D F
LO
O
R
PL
A N
, B
LD
G
TY
PI
C A
L M
O D
UL
E
FL
O
O R
PL
A
N
THIRD FLOOR PLAN, BLDG 13322
SCALE: 1/8" = 1'-0"
44 ROOF PLAN, BLDG 13322
SCALE: 1/8" = 1'-0"
NORTH
PROJECT
NORTH
TRUE
SEE SHEET A-101, FIRST & SECOND FLOOR PLAN AND TYPICAL
MODULE PLAN FOR ADDITIONAL INFORMATION.
NORTH
PROJECT
NORTH
TRUE
KEY PLAN 65
13323
13321
0 13
SCALE: NOT TO SCALE
NORTH
PROJECT
BATH
BATH
BATH
BATH
KITCHEN
CLOSETCLOSET
CLOSET CLOSET
PATIO
LAUNDRY
BATH
BATH
BATH
BATH
KITCHEN
CLOSETCLOSET
CLOSET CLOSET
PATIO
LAUNDRY
BATH
BATH
BATH
BATH
KITCHEN
CLOSETCLOSET
CLOSET CLOSET
PATIO
LAUNDRY
BEDROOM
306A
169.4 SF
BEDROOM
306B
164.7 SF
BEDROOM
306D
169.4 SF
BEDROOM
306C
164.7 SF
BEDROOM
307A
169.4 SF
BEDROOM
307B
164.7 SF
BEDROOM
307D
169.4 SF
BEDROOM
307C
164.7 SF
BEDROOM
308A
169.4 SF
BEDROOM
308B
164.7 SF
BEDROOM
308D
169.4 SF
BEDROOM
308C
164.7 SF
SLOPE
5:12 TYP.
SLOPE
5:12 TYP.
SLOPE
5:12 TYP
MIN SLOPE
1/4" PER FT TYP
42SCHEMATIC INTERIOR ELEVATIONS
SCALE: 1/4" = 1'-0"
KITCHEN (TYPICAL) LAUNDRY (TYPICAL) BATHROOM - 209A BATHROOM - 209B
(209D SIMILAR) (209C SIMILAR)
12 13 14 15
25 26 27 2728 28 26
31 31
REFERENCE NOTES 35
1. REPLACE AND REPAIR ANY (E) CONCRETE ROOF TILES, SUPPORTING STRUCTURE
(i.e. CLEATS) & BUILDING PAPER AS DISCOVERED DURING DEMOLITION
OPERATIONS. INSPECT PLYWOOD SHEATHING FOR ANY DAMAGE AND/OR NEED
TO REPAIR OR REPLACE. TYPICAL AT ALL CONCRETE TILE ROOF AREAS.
2. INSTALL (N) BUILT-UP ROOF AREA AT ALL AREAS WITH BUILT-UP ROOFING TYPICAL;
INSTALL WITH SLOPES AS SHOWN; PROVIDE 1/4" PER FT SLOPE MINIMUM AND
CRICKETS AS SHOWN.
3. PROVIDE ALL FLASHING AND COUNTER FLASHING AS REQUIRED BY CODE AND
RECOMMENDED BY MANUFACTURER.
4. NOT USED.
5. PROVIDE ALL (N) CONTINUOUS GUTTERS, DOWNSPOUTS, SCUPPERS AND
OVERFLOW SCUPPERS; ALL METALS SHALL BE PRE-FINISHED OR, IF PRE-FINISHED
MATERIAL IS NOT AVAILABLE, PAINTED TO MATCH BUILDING PAINT COLORS.
6. (N) ROOF DRAIN w/ INTEGRAL OVERFLOW INSTALLED AS INDICATED.
7. NOT USED.
8. APPROXIMATE LOCATION OF VENTILATION HOODS FOR VARIOUS SPACES IN
BUILDING; TYPICAL OF (9) SHOWN; ADDITIONAL VENT HOODS MAY BE REQUIRED;
PROVIDE EQUIPMENT COMPLIANT w/ HVAC STANDARDS ON G001.
9. LOUVERED ATTIC VENTILATION OPENING; SIZE TO BE CALCULATED AS REQUIRED
BY INTERNATIONAL BUILDING CODE; TYPICAL OF (14) SHOWN.
10. 30"w x 36"h ATTIC SPACE ACCESS DOOR; TYPICAL OF (3) SHOWN.
11. REPLACE ALL ROOF ACCESS HATCHES WITH SAME SIZE ACCESS DOORS; FIELD
VERIFY QUANTITY AND LOCATION TYPICAL.
12. REFRIGERATOR (NOT IN CONTRACT); PROVIDE 36"w BY 68"h CLEAR SPACE AS
SHOWN.
13. DRAWER BANK TYPICAL; PROVIDE (4) DRAWERS AS SHOWN.
14. PROVIDE CABINET WITH DOORS AND FIXED DRAWER PANEL AT SINK AREA.
15. PROVIDE CABINET WITH DOORS, FIXED DRAWER PANEL AND FIXED SHELF AT
RANGE AREA.
16. PROVIDE SOLID MATERIAL COUNTERTOP (CORIAN OR EQUIVALENT) AT +36" AFF
TYPICAL WITH MINIMUM 4" BACKSPLASH AT ALL COUNTERTOP AREA TYPICAL.
17. PROVIDE MICROHOOD CONVECTION OVEN COMBINATION; KENMORE ELITE
86013;VENT RANGE HOOD TO SHAFT PROVIDED; PROVIDE MINIMUM CLEARANCE
AS REQUIRED BY MANUFACTURER.
18. PROVIDE FULL OVERHEAD CABINET OVER MICROHOOD CONVECTION OVEN
WITH FIXED SHELF AS SHOWN; SIZE ACCORDING TO REQUIRED CLEARANCES AND
MINIMUM DUCT SIZING FOR HOOD.
19. PROVIDE FULL OVERHEAD CABINET WITH FIXED SHELF OVER SINK AREA WITH
BUILT-IN CONCEALED LIGHT FIXTURE UNDER CABINET; PROVIDE MINIMUM
CLEARANCE.
20. PROVIDE FULL OVERHEAD CABINET WITH (2) FIXED SHELVES AS SHOWN TYPICAL;
B.O. OF CABINET AT +18" ABOVE COUNTERTOP TYPICAL.
21. PROVIDE FULL OVERHEAD CABINET AS SHOWN TYPICAL; SIZE SET BY CLEARANCES
REQUIRED BY REFRIGERATOR (SEE NOTE 12).
22. OPEN TO BEYOND.
23. PROVIDE (3) EQUAL CABINETS WITH FIXED SHELF OVER AREA FOR WASHER AND
DRYER; SET BOTTOM OF CABINETS AT MINIMUM OF 68" AFF TYPICAL.
24. PROVIDE CABINET WITH DOOR AND DRAWER AS SHOWN TYPICAL.
25. WASHER AND DRYER (NOT IN CONTRACT); PROVIDE MINIMUM 60" CLEAR AREA
AS SHOWN.
26. 36" x 48" FIBERGLASS SHOWER PAN WITH CERAMIC TILE SURROUND AND
TEMPERED GLASS SHOWER ENCLOSURE; SHOWER CURB TO BE A MINIMUM OF 4"
TYPICAL; SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.
27. DRAWER BANK TYPICAL; PROVIDE (3) DRAWERS AS SHOWN.
28. PROVIDE CABINET WITH DOOR AND FIXED DRAWER PANEL AT SINK AREA.
29. PROVIDE A FULL WIDTH MIRROR ABOVE THE VANITY, WITH TOP OF MIRROR A
MINIMUM OF 72" ABOVE THE FINISH FLOOR; BOTTOM OF THE MIRROR SHALL
EXTEND TO THE TOP OF THE BACK SPLASH.
30. PROVIDE SOLID MATERIAL COUNTERTOP (CORIAN OR EQUIVALENT) AT +30" AFF
TYPICAL WITH MINIMUM 4" BACKSPLASH AT ALL COUNTERTOP AREA TYPICAL.
31. LOW FLOW TOILET TYPICAL; SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.
TYPICAL NOTES 55
A. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH REQUIREMENTS AS
OUTLINED IN UFC 4-010-01/02 MINIMUM ANTITERRORISM STANDARDS FOR DOD
BUILDINGS.
B. PROVIDE APPROPRIATE HVAC SYSTEM AS REQUIRED PER THE FOLLOWING:
-- UFC 3-400-01 ENERGY CONSERVATION
-- UFC 3-401-01FA UTILITY MONITORING & CONTROL SYSTEMS
-- UFC 3-410-01FA HVAC
-- ETL 04-3 : DESIGN CRITERIA FOR PREVENTION OF MOLD IN AF FACILITIES
-- UNACCOMPANIED HOUSING GUIDE, US AIR FORCE
C. SEE FINISH, DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION.
D. INSTALL SPRINKLER FIRE PROTECTION SYSTEM THROUGHOUT FACILITY COMPLIANT
WITH NFPA REQUIREMENTS.
E. CONTRACTOR SHALL PATCH AND REPAIR ALL CONCRETE SLABS TO BE
STRUCTURALLY SOUND WHERE (E) UTILITY CHASES ARE REMOVED AND NOT USED.
F. ALL NEW COMMUNICATIONS WIRING, PANELS AND EQUIPMENT TO INCLUDE
TELEVISION CABLE, TELEPHONE, WI-FI WIRING AND ALARM PANEL WIRING SHALL
MEET CURRENT STANDARDS AS DETERMINED BY 30 SPACE COMMUNICATIONS
SQUADRON.
G. ALL INTERIOR WALLS AND INFILL PANELS SHALL CONTAIN A MINIMUM OF R-19
SOUND INSULATION TYPICAL.
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF