B13121_FLRPLAN.pdf

PDF 431 KB Posted

Attached to
Commercial Internet Services for Unaccompanied Housing (UH) Dormitories
Solicitation number
FA461026Q0049
Issued by

About this file

This document is an architectural drawing set for the repair of the interior and exterior of Building 13121, a dormitory facility at what appears to be a U.S. Air Force installation (Vandenberg Space Force Base, based on contact information referencing 30 CES/CECB at 805-606-4716).

The project encompasses comprehensive renovations to first, second, and third floor layouts with typical module floor plans containing four bedrooms ranging from 164.7 to 169.4 square feet each, common areas of approximately 462.6 square feet, kitchens, laundry facilities, and multiple bathrooms. Key construction requirements include: installation of new HVAC systems compliant with UFC 3-400-01, 3-401-01FA, 3-410-01FA, and ETL 04-3 mold prevention standards; sprinkler fire protection systems meeting NFPA requirements; exterior doors and windows compliant with UFC 4-010-01/02 antiterrorism standards with blast-resistant specifications; electronic key card systems at exterior and interior bedroom doors; R-19 sound insulation in interior walls; and various mechanical systems including washer/dryer connections, range hood venting, and plumbing infrastructure. Interior finishes include specific cabinetry, countertops at designated heights, fixtures such as American Standard sinks and Price Pfister faucets, tile shower surrounds, and full-width mirrors. Roof work involves replacement of concrete tile roofing, installation of built-up roofing with specified slopes, gutters, downspouts, and drain systems. All work must comply with information safeguarding requirements per AFMAN 37-104, AFI 33-332, DOD Regulation 5400.11, and Executive Order 12958.

View the file

Other files

File Type Posted
Combo RFQ_UH WiFi_v4.pdf PDF
UHWiFi_RFI.pdf PDF
VSFB Dorm Addresses.pdf PDF
B13321_FLRPLAN.pdf PDF
B13323_FLRPLAN.pdf PDF
Aerial View.pdf PDF
B13120_B13121_FLRPLAN.pdf PDF
B13123_FLRPLAN.pdf PDF
B13320_FLRPLAN.pdf PDF
B13322_FLRPLAN.pdf PDF
B13122_FLRPLAN.pdf PDF
B13135_FLRPLAN.pdf PDF
B13321_B13323_FLRPLAN.pdf PDF
Combo RFQ_UH WiFi_v3.pdf PDF
Combo RFQ_UH WiFi_v2.pdf PDF
Atch01_SOW DORM WIFI 27 MAY 20261.pdf PDF
Combo RFQ_UH WiFi.pdf PDF
Atch02_PricingSheet.xlsx XLSX spreadsheet
Atch03_SCA WD 2015-5647 Rev 28_17Aug2026.pdf PDF
Atch04_Clauses and Provisions.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DNUP DNUP

DN

DNUP

D A

TE

D

ES

C

RI

PT

IO

N

O F

RE

V

IS

IO

N

SY

M

BO

L

PROJECT #

SHEET #

DRAWING #

D A

TE

OF

SC

A

LE

D

RA

W

IN

G T

ITL

E

PR

O

JE

C

T

TIT

LE

D

RA

W

N

RE

V

IE

W

ED

D

ES

IG

N

ED

F O

R

O

F F

I C

I A

L

U

S E

O

N L

Y

I N

F O

R M

A T

I O

N

S

A F

E G

U A

R D

I N

G

I

R

Q

U I R

D

T h e i n f o r m a t i o n c o n t a i n d o t h i s d r a w i n g s h a l l r e m a u d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r f n c t i o n a t a l l t i m e s f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a t a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n g l e a s e d i s c l o s u r d a y p a r t y b e y o e o r i g i n a l r e q u e s t a t e n d p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e

U p o n c o m p l e t i o n o f t h e u t h e d a c n t a i n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n d e s t r o y e r e c t a n y q u e s t i o n s e

E n g i n e e r i n g

S u p p o r t

E l e m e n t

C

E S

C

E C

B a t

I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r

A

F M

A N

A

F I

D a x e c u t i v d e r w h e n a p p l i c a b l e

D O

N O

T D

U

PL

IC

A

TE

T

H

IS

D R

A W

IN

G

O

R T

H E

D A

TA

C

O N

TA

IN

ED

O

N

IT

09-1255B

A-101

D

EC

A S

N O

TE

D

KR

G

KR

G

KR

G

RE

PA

IR

IN

TE

RI

O R/

EX

TE

RI

O

R O

F D

O

RM

, B

LD

G

FI

RS

T

S

EC

O N

D F

LO

O

R

PL

A N

, B

LD

G

TY

PI

C A

L M

O D

UL

E

FL

O

O R

PL

A

N

SECOND FLOOR PLAN, BLDG 13121

SCALE: 1/8" = 1'-0"

44 TYPICAL NOTES 14

FIRST FLOOR PLAN, BLDG 13121

SCALE: 1/8" = 1'-0" 42

TYPICAL MODULE FLOOR PLAN 13

REFERENCE NOTES 15

A. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH REQUIREMENTS AS

OUTLINED IN UFC 4-010-01/02 MINIMUM ANTITERRORISM STANDARDS FOR DOD

BUILDINGS.

B. PROVIDE APPROPRIATE HVAC SYSTEM AS REQUIRED PER THE FOLLOWING:

-- UFC 3-400-01 ENERGY CONSERVATION

-- UFC 3-401-01FA UTILITY MONITORING & CONTROL SYSTEMS

-- UFC 3-410-01FA HVAC

-- ETL 04-3 : DESIGN CRITERIA FOR PREVENTION OF MOLD IN AF FACILITIES

-- UNACCOMPANIED HOUSING GUIDE, US AIR FORCE

C. SEE FINISH, DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION.

D. INSTALL SPRINKLER FIRE PROTECTION SYSTEM THROUGHOUT FACILITY COMPLIANT

WITH NFPA REQUIREMENTS.

E. CONTRACTOR SHALL PATCH AND REPAIR ALL CONCRETE SLABS TO BE

STRUCTURALLY SOUND WHERE (E) UTILITY CHASES ARE REMOVED AND NOT USED.

F. ALL NEW COMMUNICATIONS WIRING, PANELS AND EQUIPMENT TO INCLUDE

TELEVISION CABLE, TELEPHONE, WI-FI WIRING AND ALARM PANEL WIRING SHALL

MEET CURRENT STANDARDS AS DETERMINED BY 30 SPACE COMMUNICATIONS

SQUADRON.

G. ALL INTERIOR WALLS AND INFILL PANELS SHALL CONTAIN A MINIMUM OF R-19

SOUND INSULATION TYPICAL.

1. PAINT AND REINSTALL AS NEEDED REFURBISHED METAL HANDRAILS, GUARDRAILS

AND METAL COLUMNS TYPICAL.

2. PATCH AND PAINT ALL EXTERIOR PLASTER SURFACES ON (E) STAIRS.

3. 5/8" GYPSUM BOARD ON 7/8" FURRING HAT CHANNELS AT ALL (E) CONCRETE

MASONRY WALLS TYPICAL.

4. 36" x 48" FIBERGLASS SHOWER PAN WITH FIBERGLASS SURROUND; SHOWER CURB

TO BE A MINIMUM OF 4" TYPICAL; PROVIDE A HEAVY-DUTY HAND-HELD

SHOWERHEAD CONNECTED TO A FLEXIBLE HOSE THAT FITS INTO AN ADJUSTABLE

HEIGHT HOLDER MOUNTED ON A VERTICAL ROD.

4.1. AMERICAN STANDARD ACRYLUX 48" x 34" SHOWER BASE, TEXTURED BOTTOM, WHITE

4.2. PRICE PFISTER 16 SERIES HANDHELD SHOWER, CHROME WITH 42 SERIES, PARISA

SHOWER FAUCET, CHROME

5. LOW-FLOW TOILET TO BE AMERICAN STANDARD CADET FLOWISE RIGHT HEIGHT

ELONGATED VALVE TYPE TOILET 1.1 GPF TOILET, WHITE

5.1. SEAT: AMERICAN STANDARD 5324.019 RISE AND SHINE SOLID PLASTIC CLOSED

FRONT SEAT WITH COVER

6. 36"w PLASTIC LAMINATE WOOD CABINET w/ UNDERCOUNTER MOUNTED SINK;

COUNTER TOP SHALL BE 30" ABOVE FINISH FLOOR; PROVIDE A MINIMUM OF (2)

8"w x 3"dp DRAWERS WITH REMAINING AREA UNDER THE VANITY AS STORAGE

WITH CABINET DOORS.

7. RECESSED MEDICINE CABINET w/ MIRROR, NOMINALLY 20"w x 26"h x 5"dp

ADJACENT TO VANITY, HINGED NEXT TO MIRROR WITH (3) ADJUSTABLE INTERIOR

SHELVES; KOHLER SINGLE DOOR ALUMINUM CABINET K-CB-CLC2026FS WITH

BUMPER TAB

8. SHELF AND POLE AT +66" AFF ON (2) WALLS AS SHOWN

9. 6" x 36" CONTINUOUS SHAFT FOR DRYER VENTING TYPICAL

10. 6" x 24" CONTINUOUS SHAFT FOR RANGE VENTING TYPICAL

11. 6" x 24" CONTINUOUS SHAFT FOR POWER/COMMUNICATION LINES AS NEEDED

12. 6" x 18" CONTINUOUS SHAFT FOR POWER/COMMUNICATION LINES AS NEEDED

13. COUNTERTOP AT +36" AFF w/ SUPPORTING WALL BELOW TYPICAL

14. WASHER TYPICAL (NIC); PROVIDE HOT/COLD WATER CONNECTIONS, POWER

AND DRAIN LINE

15. DRYER TYPICAL (NIC); PROVIDE GAS LINE, 220v OUTLET AND DRYER VENT IN

SHAFT PROVIDED. MINIMIZE BENDS AND PROVIDE REMOVABLE SCREENS FOR

CLEANOUT.

16. PROVIDE (2) BURNER ELECTRIC RANGE TYPICAL; KITCHENAID KECC056RBL,

CERAMIC GLASS SURFACE; PROVIDE MICROHOOD CONVECTION OVEN

COMBINATION; KENMORE ELITE 86013;VENT RANGE HOOD TO SHAFT PROVIDED.

17. PROVIDE 54"w PLASTIC LAMINATE WOOD CABINET w/ INSULATED STAINLESS STEEL

SINK TYPICAL; SINK TO BE AMERICAN STANDARD 7504.000 UNDERCOUNTER

MOUNT, STAINLESS STEEL WITH DISPOSAL; FAUCET TO BE AMERICAN STANDARD

4101.350 ARCH SINGLE CONTROL KITCHEN FAUCET WITH PULL-OUT SPRAY.

18. PROVIDE 36"w SPACE FOR REFRIGERATOR (NIC); PROVIDE ELECTRICAL OUTLET

AND WATER CONNECTION FOR ICE MAKER

19. INFILL (E) OPENINGS IN CMU WALL w/ STEEL STUD, INSULATION, EXTERIOR PLASTER ON EXTERIOR FACE AND 5/8" GYPSUM BOARD ON ALL INTERIOR FACES FLUSH w/

FURRED WALL OR ADJACENT INTERIOR WALL

20. TYPICAL INTERIOR WALL CONSTRUCTION SHALL BE 3 5/8" METAL STUDS w/ R-19

SOUND INSULATION AND 5/8" GYPSUM BOARD EACH SIDE

21. 6" x 24" CONTINUOUS SHAFT FOR BATHROOM VENTING AND PLUMBING

22. PROVIDE BOBRICK HEAVY DUTY 1" STAINLESS STEEL CURTAIN ROD BOB 6107X W/

FOCUS HOOKLESS SHOWER CURTAIN OR APPROVED EQUAL.

23. 14"w x 36"h PLASTIC LAMINATE WOOD CABINET w/DOOR AND COUNTERTOP TO

MATCH KITCHEN CABINETS.

24. INFILL (E) OPENING IN CMU WALL TO ACCEPT NEW DOOR OR WINDOW.

25. INFILL (E) SHAFT OPENING NOT USED THROUGH EACH FLOOR IN (E) CONCRETE

SLAB TYPICAL

26. SEAL ALL WALLS WITH APPROPRIATE WATERPROOF FINISH, CLEAN ALL FLOOR

SURFACES, REPLACE FLOOR DRAIN(S), AND GENERALLY CLEAN AREA TO RECEIVE

(N) BOILER(S), ELECTRICAL AND COMMUNICATIONS PANELS

27. 24"w FULL HT PLASTIC LAMINATE WOOD CABINET FOR RESTROOM STORAGE

28. INSTALL (N) HANDRAIL AT +34" ABV. NOSE OF (E) STAIR TYPICAL; HANDRAIL TO BE

1 1/2" PIPE RAIL, PAINTED.

29. CLEAN ALL CONCRETE TO PREPARE AREA FOR INSTALLATION OF (N) EQUIPMENT.

30. REMOVE AND REPLACE ALL FLOOR DRAINS TYPICAL; FIELD VERIFY CONDITION OF

(E) DRAIN LINES AND REPAIR AS NEEDED.

31. LINE OF (E) SOFFIT IN DORM MGR OFFICE FOR LINES (POWER, COMMUNICATIONS

AND BOILER LINES); ENSURE EVERY EFFORT IS MADE TO MINIMIZE INTRUSION INTO

DORM MGR's OFFICE WITH SOFFIT.

32. (N) 4" REINFORCED CONCRETE SLAB IN UTILITY AREA; SLOPE TO DRAIN TOWARDS

GATE TYPICAL.

33. (N) 8" CMU WALL AT 9'-4"h TYPICAL AT UTILITY AREA; PROVIDE 6' CLEAR OPENING w/ LOCKABLE GATE AS SHOWN. GATE TO BE METAL FRAME w/ SYNTHETIC WOOD

BOARDS ATTACHED TO FACE OF METAL FRAME.

34. (E) TRANSFORMER AND ELECTRICAL CABINET TO REMAIN; PAINT CABINET TO

MATCH BUILDING COLOR.

35. SEE ROOF PLAN FOR INFORMATION ON ALL ROOF AND COVERED AREAS.

36. (E) PATIO WALLS AND WALKWAYS TO REMAIN TYPICAL; CLEAN, PATCH, REPAIR

AND PAINT TO MATCH; SEE SITE PLAN FOR ADDITIONAL INFORMATION.

37. PROVIDE A FULL WIDTH MIRROR ABOVE THE VANITY, WITH TOP OF MIRROR A

MINIMUM OF 72" ABOVE THE FINISH FLOOR; BOTTOM OF THE MIRROR SHALL

EXTEND TO THE TOP OF THE BACK SPLASH.

38. 36"w OR 42"w PLASTIC LAMINATE WOOD VANITY BASE CABINET w/

UNDERCOUNTER MOUNTED SINK; VERIFY WIDTH WITH LOCATION; COUNTER TOP

SHALL BE 30" ABOVE FINISH FLOOR; PROVIDE A MINIMUM OF (2) 8"w x 3"dp

DRAWERS WITH REMAINING AREA UNDER THE VANITY AS STORAGE ACCESSED BY

CABINET DOORS.

39. PROVIDE FOR INSTALLATION OF ELECTRONIC KEY CARD SYSTEM AT EXTERIOR

SWINGING DOORS AND INTERIOR BEDROOM DOORS TYPICAL; SYSTEM SHALL BE

COMPATIBLE WITH (E) SYSTEM.

40. REINSTALL (E) ECM EQUIPMENT AND ASSOCIATED COMMUNICATIONS LINES ON

(N) BOILER(S) TYPICAL; COORDINATE EFFORT WITH 30 CES/CEAOI FOR SPECIFIC

DIRECTION AND INSTALLATION REQUIREMENTS.

41. PROVIDE CHAIN LINK MESH AND SUPPORTING STRUCTURE WITH ADEQUATE

SUPPORT TO ENSURE NO SAGGING INSTALLED HORIZONTALLY OVER EQUIPMENT

ENCLOSURE TO COMPLY WITH CURRENT ANTITERRORISM STANDARDS AND

ALLOW FOR EQUIPMENT REMOVAL.

42. PROVIDE 18"x60" MIRROR ON THE INSIDE OF THE CLOSET DOOR OR BATHROOM

DOOR AS SHOWN.

43. Not used.

44. PROVIDE (2) TOWEL BARS, EACH AT LEAST 24" LONG, WITH (1) INTEGRAL TO

SHOWER DOOR AS NOTED AND THE OTHER AT LOCATION INDICATED TYPICAL.

45. PROVIDE (1) ROBE HOOK ON THE BATHROOM SIDE OF THE BATHROOM DOOR.

46. PROVIDE WALL MOUNTED 30"w x 24"h x 8"dp PLASTIC LAMINATE WOOD

STORAGE CABINET WITH DOORS AND (1) ADJ SHELF OVER THE WAINSCOT OVER

EACH WATER CLOSET TYPICAL; FINISH TO MATCH BATHROOM VANITY CABINET.

47. PROVIDE HEAVY DUTY TOILET TISSUE HOLDER AT SIDE OF BATHROOM VANITY.

48. LAVATORY SINK (UNDERCOUNTER MOUNTED) WITH FAUCET

48.1. AMERICAN STANDARD OVALYN UNDERCOUNTER SINK 0495.300, WHITE

48.2. PRICE PFISTER, 42 SERIES, PARISA, 4" CENTERSET LAVATORY FAUCET, J42-AMFC,

POLISHED CHROME

49. INSTALL WALL MOUNTED DOOR STOPS AS NEEDED TO PREVENT DOORS FROM

DAMAGING ADJACENT SURFACES .

50. PROVIDE DOOR THRESHOLD SWEEPS AT EXTERIOR DOORS

51. PROVIDE CABINET MOUNTED FIRE EXTINGUISHER UNDER SINK IN APPROPRIATE

LOCATION.

52. PROVIDE INDIVIDUAL THERMOSTATS IN EACH BEDROOM AND COMMON SPACE.

53. PROVIDE (N) DOOR IN (E) CMU WALL; PROVIDE ALL NECESSARY STRUCTURAL

IMPROVEMENTS TO SUPPORT (E) STRUCTURE.

54. NEW CMU WALL TO MATCH EXISTING.

KEY PLAN 65

13123

13121

0 13

SCALE: NOT TO SCALE

NORTH

PROJECT

SEE TYPICAL MODULE FLOOR PLAN FOR

TYPICAL NOTES. ALL NOTES SHOWN ON THIS

DRAWING ARE NOT TYPICAL.

SCHEDULES 24

A101

E

LAUNDRY

BATH

BATHBATH

BATH

KITCHEN

CLOSET

CLOSET

CLOSET

CLOSET

BEDROOM

109A

169.4 SF

BEDROOM

109B

164.7 SF

BEDROOM

109C

164.7 SF

BEDROOM

109D

169.4 SF

PATIO PATIO

DAYROOM

109.1

434.5 SF

MECHANICAL

109.2

404.4 SF

A

LAUNDRY

SEE TYPICAL MODULE FLOOR PLAN FOR

TYPICAL NOTES. ALL NOTES SHOWN ON THIS

DRAWING ARE NOT TYPICAL.

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

6'-8"11'-4"

A301

A301

BEDROOM

210A

169.4 SF

BEDROOM

210B

164.7 SF

BEDROOM

210C

164.7 SF

BEDROOM

210D

169.4 SFKITCHEN LA

UN

D

RY

BATH

BATH

BATH

BATH BATH

BATHBATH

BATH

KITCHEN

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

BEDROOM

209A

169.4 SF

BEDROOM

209B

164.7 SF

BEDROOM

209C

164.7 SF

BEDROOM

209D

169.4 SF

PATIO PATIO

LA

UN

D

RY

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

A301

A301

'-0

8'-7"

BEDROOM

209B

164.7 SF

BEDROOM

209C

164.7 SF

KITCHEN LAUNDRY

CLOSET

BATHBATH

BATHBATH

CLOSETCLOSET

CLOSET

C

A

B

C

A

B

B B

C

CC

C

C C

15161718

CARPET / VINYL

CARPET / VINYL

VINYL / CARPET

VINYL / CARPET

V

IN

YL / C

A

RPET

V

IN

YL / C

A

RPET

C A

RPET / V

IN

YL

VINYL/CARPET

C A

RPET / V

IN

YL

50'-8" (TYPICAL MODULE)

4"3'-1 1/2"5'-6"4'-0 1/2"12'-4"12'-4"

7' -4

" T

YP

IC

A

L M

O D

UL

E

'-8

" T

YP

IC

A

L M

O D

UL

E

'-4

/2

5'

-3

/4

4' -1

/4

2'

-1

4' -0

3' -4

7'

-8

/4

3' -7

/4

3'-6"11'-4 1/2" 4'-1"

3' -0

/2

5'-4"

4'-1 1/2"

1'-0"

6' -4

/2

C A

RPET / V

IN

YL

C A

RPET / V

IN

YL

COMMON AREA

462.6 SF

47 19

CARPET / VINYL

RESTROOM

109.3

77.6 SF

WINDOW SCHEDULE

SYMBOL SIZE TYPE REMARKS

1 8046 DUAL GLAZED, SLIDER BLAST RESISTANT (INCLUDING GI Java)

2 5046 DUAL GLAZED, SLIDER FIELD VERIFY SIZE, BLAST RESISTANT

(INCLUDING GI Java)

DOOR SCHEDULE

SYMBOL SIZE TYPE REMARKS

A 3070 METAL, SOLID CORE 1616 TEMPERED GLAZING, BLAST RESISTANT

B 3070 WOOD, SOLID CORE PAINT GRADE

C 2870 WOOD, SOLID CORE PAINT GRADE

D 8070 TEMPERED GLASS SLIDER (2) FIXED PANELS, (1) SLIDER FIT TO OPENING,

BLAST RESISTANT, AT GI Java

E 6070 FIBERGLASS DOUBLE DOOR MECHANICAL ROOM DOOR ONLY

C

D

BATH

BATHBATH

BATH

KITCHEN

CLOSET

CLOSET

CLOSET

CLOSET

BEDROOM

110A

169.4 SF

BEDROOM

110B

164.7 SF

BEDROOM

110C

164.7 SF

BEDROOM

110D

169.4 SF

NORTH

PROJECT

NORTH

TRUE

NORTH

PROJECT

NORTH

TRUE

5:12

5:12

5:12

5:12

5:12

5:12

5:12

5:125:12

5:12

5:125:12

5:12

D A

TE

D

ES

C

RI

PT

IO

N

O F

RE

V

IS

IO

N

SY

M

BO

L

PROJECT #

SHEET #

DRAWING #

D A

TE

OF

SC

A

LE

D

RA

W

IN

G T

ITL

E

PR

O

JE

C

T

TIT

LE

D

RA

W

N

RE

V

IE

W

ED

D

ES

IG

N

ED

F O

R

O

F F

I C

I A

L

U

L

Y

I N

F O

R M

A T

I O

N

S

A F

E G

U A

R D

I N

G

Q

U I R

T f o r m a t i o n c o n t a i n t h i s d r a w i n g s h a l l r e m a d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r n c t i o n a t a l l t i m e f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n l e a s e d i s c l o s u d a y p a r t y b e y o e o r i g i n a l r e q u e s t a t e n d p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e

U o n c o m p l e t i o n o f t h e u t h e d a c n t a i n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n d e s t r o y e r e c t a n y q u e s t i o n s e

E n g i n e e r i n g

S u p p o r t

E l e m e n t

C

E S

C

E C

B a t

I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r

A

F M

A N

A

F I

D a x e c u t i v d e r w h e n a p p l i c a b l e

D O

N O

T D

U

PL

IC

A

TE

T

H

IS

D R

A W

IN

G

O

R T

H E

D A

TA

C

O N

TA

IN

ED

O

N

IT

09-1255B

A102

D

EC

A S

N O

TE

D

KR

G

KR

G

KR

G

RE

PA

IR

IN

TE

RI

O R/

EX

TE

RI

O

R O

F D

O

RM

, B

LD

G

FI

RS

T

S

EC

O N

D F

LO

O

R

PL

A N

, B

LD

G

TY

PI

C A

L M

O D

UL

E

FL

O

O R

PL

A

N

ROOF PLAN, BLDG 13121

SCALE: 1/8" = 1'-0"

THIRD FLOOR PLAN, BLDG 13121

SCALE: 1/8" = 1'-0"

REFERENCE NOTES 35

1. REPLACE AND REPAIR ANY (E) CONCRETE ROOF TILES, SUPPORTING STRUCTURE

(i.e. CLEATS) & BUILDING PAPER AS DISCOVERED DURING DEMOLITION

OPERATIONS. INSPECT PLYWOOD SHEATHING FOR ANY DAMAGE AND/OR NEED

TO REPAIR OR REPLACE. TYPICAL AT ALL CONCRETE TILE ROOF AREAS.

2. INSTALL (N) BUILT-UP ROOF AREA AT ALL AREAS WITH BUILT-UP ROOFING TYPICAL;

INSTALL WITH SLOPES AS SHOWN; PROVIDE 1/4" PER FT SLOPE MINIMUM AND

CRICKETS AS SHOWN.

3. PROVIDE ALL FLASHING AND COUNTER FLASHING AS REQUIRED BY CODE AND

RECOMMENDED BY MANUFACTURER.

4. PROVIDE ROOF VENTING AS NEEDED w/ PROPER FLASHING/COUNTER FLASHING

FOR ALL (N) EQUIPMENT IN MECHANICAL ROOM.

5. PROVIDE ALL (N) CONTINUOUS GUTTERS, DOWNSPOUTS, SCUPPERS AND

OVERFLOW SCUPPERS; ALL METALS SHALL BE PRE-FINISHED OR, IF PRE-FINISHED

MATERIAL IS NOT AVAILABLE, PAINTED TO MATCH BUILDING PAINT COLORS.

6. (N) ROOF DRAIN w/ INTEGRAL OVERFLOW INSTALLED AS INDICATED.

7. PROVIDE CHAIN LINK MESH AND SUPPORTING STRUCTURE WITH ADEQUATE

SUPPORT TO ENSURE NO SAGGING INSTALLED HORIZONTALLY OVER EQUIPMENT

ENCLOSURE TO COMPLY WITH CURRENT ANTITERRORISM STANDARDS, UFC

4-010-01 MINIMUM ANTITERRORISM STANDARDS FOR DOD BUILDINGS.

8. APPROXIMATE LOCATION OF VENTILATION HOODS FOR VARIOUS SPACES IN

BUILDING; TYPICAL OF (6) SHOWN; ADDITIONAL VENT HOODS MAY BE REQUIRED;

PROVIDE EQUIPMENT COMPLIANT w/ HVAC STANDARDS ON G001.

9. LOUVERED ATTIC VENTILATION OPENING; SIZE TO BE CALCULATED AS REQUIRED

BY INTERNATIONAL BUILDING CODE; TYPICAL OF (14) SHOWN.

10. 30"w x 36"h ATTIC SPACE ACCESS DOOR; TYPICAL OF (2) SHOWN.

11. REPLACE ALL ROOF ACCESS HATCHES WITH SAME SIZE ACCESS DOORS; FIELD

VERIFY QUANTITY AND LOCATION TYPICAL.

12. REFRIGERATOR (NOT IN CONTRACT); PROVIDE 36"w BY 68"h CLEAR SPACE AS

SHOWN.

13. DRAWER BANK TYPICAL; PROVIDE (4) DRAWERS AS SHOWN.

14. PROVIDE CABINET WITH DOORS AND FIXED DRAWER PANEL AT SINK AREA.

15. PROVIDE CABINET WITH DOORS, FIXED DRAWER PANEL AND FIXED SHELF AT

RANGE AREA.

16. PROVIDE SOLID MATERIAL COUNTERTOP (CORIAN OR EQUIVALENT) AT +36" AFF

TYPICAL WITH MINIMUM 4" BACKSPLASH AT ALL COUNTERTOP AREA TYPICAL.

17. PROVIDE MICROHOOD CONVECTION OVEN COMBINATION; KENMORE ELITE

86013;VENT RANGE HOOD TO SHAFT PROVIDED; PROVIDE MINIMUM CLEARANCE

AS REQUIRED BY MANUFACTURER.

18. PROVIDE FULL OVERHEAD CABINET OVER MICROHOOD CONVECTION OVEN

WITH FIXED SHELF AS SHOWN; SIZE ACCORDING TO REQUIRED CLEARANCES AND

MINIMUM DUCT SIZING FOR HOOD.

19. PROVIDE FULL OVERHEAD CABINET WITH FIXED SHELF OVER SINK AREA WITH

BUILT-IN CONCEALED LIGHT FIXTURE UNDER CABINET; PROVIDE MINIMUM

CLEARANCE.

20. PROVIDE FULL OVERHEAD CABINET WITH (2) FIXED SHELVES AS SHOWN TYPICAL;

B.O. OF CABINET AT +18" ABOVE COUNTERTOP TYPICAL.

21. PROVIDE FULL OVERHEAD CABINET AS SHOWN TYPICAL; SIZE SET BY CLEARANCES

REQUIRED BY REFRIGERATOR (SEE NOTE 12).

22. OPEN TO BEYOND.

23. PROVIDE (3) EQUAL CABINETS WITH FIXED SHELF OVER AREA FOR WASHER AND

DRYER; SET BOTTOM OF CABINETS AT MINIMUM OF 68" AFF TYPICAL.

24. PROVIDE CABINET WITH DOOR AND DRAWER AS SHOWN TYPICAL.

25. WASHER AND DRYER (NOT IN CONTRACT); PROVIDE MINIMUM 60" CLEAR AREA

AS SHOWN.

26. 36" x 48" FIBERGLASS SHOWER PAN WITH CERAMIC TILE SURROUND AND

TEMPERED GLASS SHOWER ENCLOSURE; SHOWER CURB TO BE A MINIMUM OF 4"

TYPICAL; SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.

27. DRAWER BANK TYPICAL; PROVIDE (3) DRAWERS AS SHOWN.

28. PROVIDE CABINET WITH DOOR AND FIXED DRAWER PANEL AT SINK AREA.

29. PROVIDE A FULL WIDTH MIRROR ABOVE THE VANITY, WITH TOP OF MIRROR A

MINIMUM OF 72" ABOVE THE FINISH FLOOR; BOTTOM OF THE MIRROR SHALL

EXTEND TO THE TOP OF THE BACK SPLASH.

30. PROVIDE SOLID MATERIAL COUNTERTOP (CORIAN OR EQUIVALENT) AT +30" AFF

TYPICAL WITH MINIMUM 4" BACKSPLASH AT ALL COUNTERTOP AREA TYPICAL.

31. LOW FLOW TOILET TYPICAL; SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.

KEY PLAN 65

13123

13121

0 13

SCALE: NOT TO SCALE

NORTH

PROJECT

SEE TYPICAL MODULE FLOOR PLAN FOR

TYPICAL NOTES. ALL NOTES SHOWN ON THIS

DRAWING ARE NOT TYPICAL.

SEE TYPICAL MODULE FLOOR PLAN FOR

TYPICAL NOTES. ALL NOTES SHOWN ON THIS

DRAWING ARE NOT TYPICAL.

TYPICAL NOTES 55

A. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH REQUIREMENTS AS

OUTLINED IN UFC 4-010-01/02 MINIMUM ANTITERRORISM STANDARDS FOR DOD

BUILDINGS.

B. PROVIDE APPROPRIATE HVAC SYSTEM AS REQUIRED PER THE FOLLOWING:

-- UFC 3-400-01 ENERGY CONSERVATION

-- UFC 3-401-01FA UTILITY MONITORING & CONTROL SYSTEMS

-- UFC 3-410-01FA HVAC

-- ETL 04-3 : DESIGN CRITERIA FOR PREVENTION OF MOLD IN AF FACILITIES

-- UNACCOMPANIED HOUSING GUIDE, US AIR FORCE

C. SEE FINISH, DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION.

D. INSTALL SPRINKLER FIRE PROTECTION SYSTEM THROUGHOUT FACILITY COMPLIANT

WITH NFPA REQUIREMENTS.

E. CONTRACTOR SHALL PATCH AND REPAIR ALL CONCRETE SLABS TO BE

STRUCTURALLY SOUND WHERE (E) UTILITY CHASES ARE REMOVED AND NOT USED.

F. ALL NEW COMMUNICATIONS WIRING, PANELS AND EQUIPMENT TO INCLUDE

TELEVISION CABLE, TELEPHONE, WI-FI WIRING AND ALARM PANEL WIRING SHALL

MEET CURRENT STANDARDS AS DETERMINED BY 30 SPACE COMMUNICATIONS

SQUADRON.

G. ALL INTERIOR WALLS AND INFILL PANELS SHALL CONTAIN A MINIMUM OF R-19

SOUND INSULATION TYPICAL.

42SCHEMATIC INTERIOR ELEVATIONS

SCALE: 1/4" = 1'-0"

KITCHEN AND LAUNDRY (TYPICAL) BATHROOM - 209A BATHROOM - 209B

(209D SIMILAR) (209C SIMILAR)

BEDROOM

310A

169.4 SF

BEDROOM

310B

164.7 SF

BEDROOM

310C

164.7 SF

BEDROOM

310D

169.4 SFKITCHEN

LAUNDRY

BATH

BATH

BATH

BATH BATH

BATHBATH

BATH

KITCHEN

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

BEDROOM

309A

169.4 SF

BEDROOM

309B

164.7 SF

BEDROOM

309C

164.7 SF

BEDROOM

309D

169.4 SF

PATIO PATIO

LAUNDRY

COMMON AREA

462.6 SF

COMMON AREA

462.6 SF

A301

A301

5 5

A301

A301

NORTH

PROJECT

NORTH

TRUE

26 27 2728 28 26

31 3112 13 14 15

NORTH

PROJECT

NORTH

TRUE

File details come from the government source that posted it. Updated .