This document is an architectural drawing set for the repair of the interior and exterior of Building 13121, a dormitory facility at what appears to be a U.S. Air Force installation (Vandenberg Space Force Base, based on contact information referencing 30 CES/CECB at 805-606-4716).
The project encompasses comprehensive renovations to first, second, and third floor layouts with typical module floor plans containing four bedrooms ranging from 164.7 to 169.4 square feet each, common areas of approximately 462.6 square feet, kitchens, laundry facilities, and multiple bathrooms. Key construction requirements include: installation of new HVAC systems compliant with UFC 3-400-01, 3-401-01FA, 3-410-01FA, and ETL 04-3 mold prevention standards; sprinkler fire protection systems meeting NFPA requirements; exterior doors and windows compliant with UFC 4-010-01/02 antiterrorism standards with blast-resistant specifications; electronic key card systems at exterior and interior bedroom doors; R-19 sound insulation in interior walls; and various mechanical systems including washer/dryer connections, range hood venting, and plumbing infrastructure. Interior finishes include specific cabinetry, countertops at designated heights, fixtures such as American Standard sinks and Price Pfister faucets, tile shower surrounds, and full-width mirrors. Roof work involves replacement of concrete tile roofing, installation of built-up roofing with specified slopes, gutters, downspouts, and drain systems. All work must comply with information safeguarding requirements per AFMAN 37-104, AFI 33-332, DOD Regulation 5400.11, and Executive Order 12958.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Combo RFQ_UH WiFi_v4.pdf | ||
| UHWiFi_RFI.pdf | ||
| VSFB Dorm Addresses.pdf | ||
| B13321_FLRPLAN.pdf | ||
| B13323_FLRPLAN.pdf | ||
| Aerial View.pdf | ||
| B13120_B13121_FLRPLAN.pdf | ||
| B13123_FLRPLAN.pdf | ||
| B13320_FLRPLAN.pdf | ||
| B13322_FLRPLAN.pdf | ||
| B13122_FLRPLAN.pdf | ||
| B13135_FLRPLAN.pdf | ||
| B13321_B13323_FLRPLAN.pdf | ||
| Combo RFQ_UH WiFi_v3.pdf | ||
| Combo RFQ_UH WiFi_v2.pdf | ||
| Atch01_SOW DORM WIFI 27 MAY 20261.pdf | ||
| Combo RFQ_UH WiFi.pdf | ||
| Atch02_PricingSheet.xlsx | XLSX spreadsheet | |
| Atch03_SCA WD 2015-5647 Rev 28_17Aug2026.pdf | ||
| Atch04_Clauses and Provisions.pdf |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DNUP DNUP
DN
DNUP
D A
TE
D
ES
C
RI
PT
IO
N
O F
RE
V
IS
IO
N
SY
M
BO
L
PROJECT #
SHEET #
DRAWING #
D A
TE
OF
SC
A
LE
D
RA
W
IN
G T
ITL
E
PR
O
JE
C
T
TIT
LE
D
RA
W
N
RE
V
IE
W
ED
D
ES
IG
N
ED
F O
R
O
F F
I C
I A
L
U
S E
O
N L
Y
I N
F O
R M
A T
I O
N
S
A F
E G
U A
R D
I N
G
I
R
Q
U I R
D
T h e i n f o r m a t i o n c o n t a i n d o t h i s d r a w i n g s h a l l r e m a u d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r f n c t i o n a t a l l t i m e s f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a t a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n g l e a s e d i s c l o s u r d a y p a r t y b e y o e o r i g i n a l r e q u e s t a t e n d p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e
U p o n c o m p l e t i o n o f t h e u t h e d a c n t a i n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n d e s t r o y e r e c t a n y q u e s t i o n s e
E n g i n e e r i n g
S u p p o r t
E l e m e n t
C
E S
C
E C
B a t
I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r
A
F M
A N
A
F I
D a x e c u t i v d e r w h e n a p p l i c a b l e
D O
N O
T D
U
PL
IC
A
TE
T
H
IS
D R
A W
IN
G
O
R T
H E
D A
TA
C
O N
TA
IN
ED
O
N
IT
09-1255B
A-101
D
EC
A S
N O
TE
D
KR
G
KR
G
KR
G
RE
PA
IR
IN
TE
RI
O R/
EX
TE
RI
O
R O
F D
O
RM
, B
LD
G
FI
RS
T
S
EC
O N
D F
LO
O
R
PL
A N
, B
LD
G
TY
PI
C A
L M
O D
UL
E
FL
O
O R
PL
A
N
SECOND FLOOR PLAN, BLDG 13121
SCALE: 1/8" = 1'-0"
44 TYPICAL NOTES 14
FIRST FLOOR PLAN, BLDG 13121
SCALE: 1/8" = 1'-0" 42
TYPICAL MODULE FLOOR PLAN 13
REFERENCE NOTES 15
A. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH REQUIREMENTS AS
OUTLINED IN UFC 4-010-01/02 MINIMUM ANTITERRORISM STANDARDS FOR DOD
BUILDINGS.
B. PROVIDE APPROPRIATE HVAC SYSTEM AS REQUIRED PER THE FOLLOWING:
-- UFC 3-400-01 ENERGY CONSERVATION
-- UFC 3-401-01FA UTILITY MONITORING & CONTROL SYSTEMS
-- UFC 3-410-01FA HVAC
-- ETL 04-3 : DESIGN CRITERIA FOR PREVENTION OF MOLD IN AF FACILITIES
-- UNACCOMPANIED HOUSING GUIDE, US AIR FORCE
C. SEE FINISH, DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION.
D. INSTALL SPRINKLER FIRE PROTECTION SYSTEM THROUGHOUT FACILITY COMPLIANT
WITH NFPA REQUIREMENTS.
E. CONTRACTOR SHALL PATCH AND REPAIR ALL CONCRETE SLABS TO BE
STRUCTURALLY SOUND WHERE (E) UTILITY CHASES ARE REMOVED AND NOT USED.
F. ALL NEW COMMUNICATIONS WIRING, PANELS AND EQUIPMENT TO INCLUDE
TELEVISION CABLE, TELEPHONE, WI-FI WIRING AND ALARM PANEL WIRING SHALL
MEET CURRENT STANDARDS AS DETERMINED BY 30 SPACE COMMUNICATIONS
SQUADRON.
G. ALL INTERIOR WALLS AND INFILL PANELS SHALL CONTAIN A MINIMUM OF R-19
SOUND INSULATION TYPICAL.
1. PAINT AND REINSTALL AS NEEDED REFURBISHED METAL HANDRAILS, GUARDRAILS
AND METAL COLUMNS TYPICAL.
2. PATCH AND PAINT ALL EXTERIOR PLASTER SURFACES ON (E) STAIRS.
3. 5/8" GYPSUM BOARD ON 7/8" FURRING HAT CHANNELS AT ALL (E) CONCRETE
MASONRY WALLS TYPICAL.
4. 36" x 48" FIBERGLASS SHOWER PAN WITH FIBERGLASS SURROUND; SHOWER CURB
TO BE A MINIMUM OF 4" TYPICAL; PROVIDE A HEAVY-DUTY HAND-HELD
SHOWERHEAD CONNECTED TO A FLEXIBLE HOSE THAT FITS INTO AN ADJUSTABLE
HEIGHT HOLDER MOUNTED ON A VERTICAL ROD.
4.1. AMERICAN STANDARD ACRYLUX 48" x 34" SHOWER BASE, TEXTURED BOTTOM, WHITE
4.2. PRICE PFISTER 16 SERIES HANDHELD SHOWER, CHROME WITH 42 SERIES, PARISA
SHOWER FAUCET, CHROME
5. LOW-FLOW TOILET TO BE AMERICAN STANDARD CADET FLOWISE RIGHT HEIGHT
ELONGATED VALVE TYPE TOILET 1.1 GPF TOILET, WHITE
5.1. SEAT: AMERICAN STANDARD 5324.019 RISE AND SHINE SOLID PLASTIC CLOSED
FRONT SEAT WITH COVER
6. 36"w PLASTIC LAMINATE WOOD CABINET w/ UNDERCOUNTER MOUNTED SINK;
COUNTER TOP SHALL BE 30" ABOVE FINISH FLOOR; PROVIDE A MINIMUM OF (2)
8"w x 3"dp DRAWERS WITH REMAINING AREA UNDER THE VANITY AS STORAGE
WITH CABINET DOORS.
7. RECESSED MEDICINE CABINET w/ MIRROR, NOMINALLY 20"w x 26"h x 5"dp
ADJACENT TO VANITY, HINGED NEXT TO MIRROR WITH (3) ADJUSTABLE INTERIOR
SHELVES; KOHLER SINGLE DOOR ALUMINUM CABINET K-CB-CLC2026FS WITH
BUMPER TAB
8. SHELF AND POLE AT +66" AFF ON (2) WALLS AS SHOWN
9. 6" x 36" CONTINUOUS SHAFT FOR DRYER VENTING TYPICAL
10. 6" x 24" CONTINUOUS SHAFT FOR RANGE VENTING TYPICAL
11. 6" x 24" CONTINUOUS SHAFT FOR POWER/COMMUNICATION LINES AS NEEDED
12. 6" x 18" CONTINUOUS SHAFT FOR POWER/COMMUNICATION LINES AS NEEDED
13. COUNTERTOP AT +36" AFF w/ SUPPORTING WALL BELOW TYPICAL
14. WASHER TYPICAL (NIC); PROVIDE HOT/COLD WATER CONNECTIONS, POWER
AND DRAIN LINE
15. DRYER TYPICAL (NIC); PROVIDE GAS LINE, 220v OUTLET AND DRYER VENT IN
SHAFT PROVIDED. MINIMIZE BENDS AND PROVIDE REMOVABLE SCREENS FOR
CLEANOUT.
16. PROVIDE (2) BURNER ELECTRIC RANGE TYPICAL; KITCHENAID KECC056RBL,
CERAMIC GLASS SURFACE; PROVIDE MICROHOOD CONVECTION OVEN
COMBINATION; KENMORE ELITE 86013;VENT RANGE HOOD TO SHAFT PROVIDED.
17. PROVIDE 54"w PLASTIC LAMINATE WOOD CABINET w/ INSULATED STAINLESS STEEL
SINK TYPICAL; SINK TO BE AMERICAN STANDARD 7504.000 UNDERCOUNTER
MOUNT, STAINLESS STEEL WITH DISPOSAL; FAUCET TO BE AMERICAN STANDARD
4101.350 ARCH SINGLE CONTROL KITCHEN FAUCET WITH PULL-OUT SPRAY.
18. PROVIDE 36"w SPACE FOR REFRIGERATOR (NIC); PROVIDE ELECTRICAL OUTLET
AND WATER CONNECTION FOR ICE MAKER
19. INFILL (E) OPENINGS IN CMU WALL w/ STEEL STUD, INSULATION, EXTERIOR PLASTER ON EXTERIOR FACE AND 5/8" GYPSUM BOARD ON ALL INTERIOR FACES FLUSH w/
FURRED WALL OR ADJACENT INTERIOR WALL
20. TYPICAL INTERIOR WALL CONSTRUCTION SHALL BE 3 5/8" METAL STUDS w/ R-19
SOUND INSULATION AND 5/8" GYPSUM BOARD EACH SIDE
21. 6" x 24" CONTINUOUS SHAFT FOR BATHROOM VENTING AND PLUMBING
22. PROVIDE BOBRICK HEAVY DUTY 1" STAINLESS STEEL CURTAIN ROD BOB 6107X W/
FOCUS HOOKLESS SHOWER CURTAIN OR APPROVED EQUAL.
23. 14"w x 36"h PLASTIC LAMINATE WOOD CABINET w/DOOR AND COUNTERTOP TO
MATCH KITCHEN CABINETS.
24. INFILL (E) OPENING IN CMU WALL TO ACCEPT NEW DOOR OR WINDOW.
25. INFILL (E) SHAFT OPENING NOT USED THROUGH EACH FLOOR IN (E) CONCRETE
SLAB TYPICAL
26. SEAL ALL WALLS WITH APPROPRIATE WATERPROOF FINISH, CLEAN ALL FLOOR
SURFACES, REPLACE FLOOR DRAIN(S), AND GENERALLY CLEAN AREA TO RECEIVE
(N) BOILER(S), ELECTRICAL AND COMMUNICATIONS PANELS
27. 24"w FULL HT PLASTIC LAMINATE WOOD CABINET FOR RESTROOM STORAGE
28. INSTALL (N) HANDRAIL AT +34" ABV. NOSE OF (E) STAIR TYPICAL; HANDRAIL TO BE
1 1/2" PIPE RAIL, PAINTED.
29. CLEAN ALL CONCRETE TO PREPARE AREA FOR INSTALLATION OF (N) EQUIPMENT.
30. REMOVE AND REPLACE ALL FLOOR DRAINS TYPICAL; FIELD VERIFY CONDITION OF
(E) DRAIN LINES AND REPAIR AS NEEDED.
31. LINE OF (E) SOFFIT IN DORM MGR OFFICE FOR LINES (POWER, COMMUNICATIONS
AND BOILER LINES); ENSURE EVERY EFFORT IS MADE TO MINIMIZE INTRUSION INTO
DORM MGR's OFFICE WITH SOFFIT.
32. (N) 4" REINFORCED CONCRETE SLAB IN UTILITY AREA; SLOPE TO DRAIN TOWARDS
GATE TYPICAL.
33. (N) 8" CMU WALL AT 9'-4"h TYPICAL AT UTILITY AREA; PROVIDE 6' CLEAR OPENING w/ LOCKABLE GATE AS SHOWN. GATE TO BE METAL FRAME w/ SYNTHETIC WOOD
BOARDS ATTACHED TO FACE OF METAL FRAME.
34. (E) TRANSFORMER AND ELECTRICAL CABINET TO REMAIN; PAINT CABINET TO
MATCH BUILDING COLOR.
35. SEE ROOF PLAN FOR INFORMATION ON ALL ROOF AND COVERED AREAS.
36. (E) PATIO WALLS AND WALKWAYS TO REMAIN TYPICAL; CLEAN, PATCH, REPAIR
AND PAINT TO MATCH; SEE SITE PLAN FOR ADDITIONAL INFORMATION.
37. PROVIDE A FULL WIDTH MIRROR ABOVE THE VANITY, WITH TOP OF MIRROR A
MINIMUM OF 72" ABOVE THE FINISH FLOOR; BOTTOM OF THE MIRROR SHALL
EXTEND TO THE TOP OF THE BACK SPLASH.
38. 36"w OR 42"w PLASTIC LAMINATE WOOD VANITY BASE CABINET w/
UNDERCOUNTER MOUNTED SINK; VERIFY WIDTH WITH LOCATION; COUNTER TOP
SHALL BE 30" ABOVE FINISH FLOOR; PROVIDE A MINIMUM OF (2) 8"w x 3"dp
DRAWERS WITH REMAINING AREA UNDER THE VANITY AS STORAGE ACCESSED BY
CABINET DOORS.
39. PROVIDE FOR INSTALLATION OF ELECTRONIC KEY CARD SYSTEM AT EXTERIOR
SWINGING DOORS AND INTERIOR BEDROOM DOORS TYPICAL; SYSTEM SHALL BE
COMPATIBLE WITH (E) SYSTEM.
40. REINSTALL (E) ECM EQUIPMENT AND ASSOCIATED COMMUNICATIONS LINES ON
(N) BOILER(S) TYPICAL; COORDINATE EFFORT WITH 30 CES/CEAOI FOR SPECIFIC
DIRECTION AND INSTALLATION REQUIREMENTS.
41. PROVIDE CHAIN LINK MESH AND SUPPORTING STRUCTURE WITH ADEQUATE
SUPPORT TO ENSURE NO SAGGING INSTALLED HORIZONTALLY OVER EQUIPMENT
ENCLOSURE TO COMPLY WITH CURRENT ANTITERRORISM STANDARDS AND
ALLOW FOR EQUIPMENT REMOVAL.
42. PROVIDE 18"x60" MIRROR ON THE INSIDE OF THE CLOSET DOOR OR BATHROOM
DOOR AS SHOWN.
43. Not used.
44. PROVIDE (2) TOWEL BARS, EACH AT LEAST 24" LONG, WITH (1) INTEGRAL TO
SHOWER DOOR AS NOTED AND THE OTHER AT LOCATION INDICATED TYPICAL.
45. PROVIDE (1) ROBE HOOK ON THE BATHROOM SIDE OF THE BATHROOM DOOR.
46. PROVIDE WALL MOUNTED 30"w x 24"h x 8"dp PLASTIC LAMINATE WOOD
STORAGE CABINET WITH DOORS AND (1) ADJ SHELF OVER THE WAINSCOT OVER
EACH WATER CLOSET TYPICAL; FINISH TO MATCH BATHROOM VANITY CABINET.
47. PROVIDE HEAVY DUTY TOILET TISSUE HOLDER AT SIDE OF BATHROOM VANITY.
48. LAVATORY SINK (UNDERCOUNTER MOUNTED) WITH FAUCET
48.1. AMERICAN STANDARD OVALYN UNDERCOUNTER SINK 0495.300, WHITE
48.2. PRICE PFISTER, 42 SERIES, PARISA, 4" CENTERSET LAVATORY FAUCET, J42-AMFC,
POLISHED CHROME
49. INSTALL WALL MOUNTED DOOR STOPS AS NEEDED TO PREVENT DOORS FROM
DAMAGING ADJACENT SURFACES .
50. PROVIDE DOOR THRESHOLD SWEEPS AT EXTERIOR DOORS
51. PROVIDE CABINET MOUNTED FIRE EXTINGUISHER UNDER SINK IN APPROPRIATE
LOCATION.
52. PROVIDE INDIVIDUAL THERMOSTATS IN EACH BEDROOM AND COMMON SPACE.
53. PROVIDE (N) DOOR IN (E) CMU WALL; PROVIDE ALL NECESSARY STRUCTURAL
IMPROVEMENTS TO SUPPORT (E) STRUCTURE.
54. NEW CMU WALL TO MATCH EXISTING.
KEY PLAN 65
13123
13121
0 13
SCALE: NOT TO SCALE
NORTH
PROJECT
SEE TYPICAL MODULE FLOOR PLAN FOR
TYPICAL NOTES. ALL NOTES SHOWN ON THIS
DRAWING ARE NOT TYPICAL.
SCHEDULES 24
A101
E
LAUNDRY
BATH
BATHBATH
BATH
KITCHEN
CLOSET
CLOSET
CLOSET
CLOSET
BEDROOM
109A
169.4 SF
BEDROOM
109B
164.7 SF
BEDROOM
109C
164.7 SF
BEDROOM
109D
169.4 SF
PATIO PATIO
DAYROOM
109.1
434.5 SF
MECHANICAL
109.2
404.4 SF
A
LAUNDRY
SEE TYPICAL MODULE FLOOR PLAN FOR
TYPICAL NOTES. ALL NOTES SHOWN ON THIS
DRAWING ARE NOT TYPICAL.
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
6'-8"11'-4"
A301
A301
BEDROOM
210A
169.4 SF
BEDROOM
210B
164.7 SF
BEDROOM
210C
164.7 SF
BEDROOM
210D
169.4 SFKITCHEN LA
UN
D
RY
BATH
BATH
BATH
BATH BATH
BATHBATH
BATH
KITCHEN
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
BEDROOM
209A
169.4 SF
BEDROOM
209B
164.7 SF
BEDROOM
209C
164.7 SF
BEDROOM
209D
169.4 SF
PATIO PATIO
LA
UN
D
RY
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
A301
A301
'-0
8'-7"
BEDROOM
209B
164.7 SF
BEDROOM
209C
164.7 SF
KITCHEN LAUNDRY
CLOSET
BATHBATH
BATHBATH
CLOSETCLOSET
CLOSET
C
A
B
C
A
B
B B
C
CC
C
C C
15161718
CARPET / VINYL
CARPET / VINYL
VINYL / CARPET
VINYL / CARPET
V
IN
YL / C
A
RPET
V
IN
YL / C
A
RPET
C A
RPET / V
IN
YL
VINYL/CARPET
C A
RPET / V
IN
YL
50'-8" (TYPICAL MODULE)
4"3'-1 1/2"5'-6"4'-0 1/2"12'-4"12'-4"
7' -4
" T
YP
IC
A
L M
O D
UL
E
'-8
" T
YP
IC
A
L M
O D
UL
E
'-4
/2
5'
-3
/4
4' -1
/4
2'
-1
4' -0
3' -4
7'
-8
/4
3' -7
/4
3'-6"11'-4 1/2" 4'-1"
3' -0
/2
5'-4"
4'-1 1/2"
1'-0"
6' -4
/2
C A
RPET / V
IN
YL
C A
RPET / V
IN
YL
COMMON AREA
462.6 SF
47 19
CARPET / VINYL
RESTROOM
109.3
77.6 SF
WINDOW SCHEDULE
SYMBOL SIZE TYPE REMARKS
1 8046 DUAL GLAZED, SLIDER BLAST RESISTANT (INCLUDING GI Java)
2 5046 DUAL GLAZED, SLIDER FIELD VERIFY SIZE, BLAST RESISTANT
(INCLUDING GI Java)
DOOR SCHEDULE
SYMBOL SIZE TYPE REMARKS
A 3070 METAL, SOLID CORE 1616 TEMPERED GLAZING, BLAST RESISTANT
B 3070 WOOD, SOLID CORE PAINT GRADE
C 2870 WOOD, SOLID CORE PAINT GRADE
D 8070 TEMPERED GLASS SLIDER (2) FIXED PANELS, (1) SLIDER FIT TO OPENING,
BLAST RESISTANT, AT GI Java
E 6070 FIBERGLASS DOUBLE DOOR MECHANICAL ROOM DOOR ONLY
C
D
BATH
BATHBATH
BATH
KITCHEN
CLOSET
CLOSET
CLOSET
CLOSET
BEDROOM
110A
169.4 SF
BEDROOM
110B
164.7 SF
BEDROOM
110C
164.7 SF
BEDROOM
110D
169.4 SF
NORTH
PROJECT
NORTH
TRUE
NORTH
PROJECT
NORTH
TRUE
5:12
5:12
5:12
5:12
5:12
5:12
5:12
5:125:12
5:12
5:125:12
5:12
D A
TE
D
ES
C
RI
PT
IO
N
O F
RE
V
IS
IO
N
SY
M
BO
L
PROJECT #
SHEET #
DRAWING #
D A
TE
OF
SC
A
LE
D
RA
W
IN
G T
ITL
E
PR
O
JE
C
T
TIT
LE
D
RA
W
N
RE
V
IE
W
ED
D
ES
IG
N
ED
F O
R
O
F F
I C
I A
L
U
L
Y
I N
F O
R M
A T
I O
N
S
A F
E G
U A
R D
I N
G
Q
U I R
T f o r m a t i o n c o n t a i n t h i s d r a w i n g s h a l l r e m a d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r n c t i o n a t a l l t i m e f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n l e a s e d i s c l o s u d a y p a r t y b e y o e o r i g i n a l r e q u e s t a t e n d p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e
U o n c o m p l e t i o n o f t h e u t h e d a c n t a i n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n d e s t r o y e r e c t a n y q u e s t i o n s e
E n g i n e e r i n g
S u p p o r t
E l e m e n t
C
E S
C
E C
B a t
I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r
A
F M
A N
A
F I
D a x e c u t i v d e r w h e n a p p l i c a b l e
D O
N O
T D
U
PL
IC
A
TE
T
H
IS
D R
A W
IN
G
O
R T
H E
D A
TA
C
O N
TA
IN
ED
O
N
IT
09-1255B
A102
D
EC
A S
N O
TE
D
KR
G
KR
G
KR
G
RE
PA
IR
IN
TE
RI
O R/
EX
TE
RI
O
R O
F D
O
RM
, B
LD
G
FI
RS
T
S
EC
O N
D F
LO
O
R
PL
A N
, B
LD
G
TY
PI
C A
L M
O D
UL
E
FL
O
O R
PL
A
N
ROOF PLAN, BLDG 13121
SCALE: 1/8" = 1'-0"
THIRD FLOOR PLAN, BLDG 13121
SCALE: 1/8" = 1'-0"
REFERENCE NOTES 35
1. REPLACE AND REPAIR ANY (E) CONCRETE ROOF TILES, SUPPORTING STRUCTURE
(i.e. CLEATS) & BUILDING PAPER AS DISCOVERED DURING DEMOLITION
OPERATIONS. INSPECT PLYWOOD SHEATHING FOR ANY DAMAGE AND/OR NEED
TO REPAIR OR REPLACE. TYPICAL AT ALL CONCRETE TILE ROOF AREAS.
2. INSTALL (N) BUILT-UP ROOF AREA AT ALL AREAS WITH BUILT-UP ROOFING TYPICAL;
INSTALL WITH SLOPES AS SHOWN; PROVIDE 1/4" PER FT SLOPE MINIMUM AND
CRICKETS AS SHOWN.
3. PROVIDE ALL FLASHING AND COUNTER FLASHING AS REQUIRED BY CODE AND
RECOMMENDED BY MANUFACTURER.
4. PROVIDE ROOF VENTING AS NEEDED w/ PROPER FLASHING/COUNTER FLASHING
FOR ALL (N) EQUIPMENT IN MECHANICAL ROOM.
5. PROVIDE ALL (N) CONTINUOUS GUTTERS, DOWNSPOUTS, SCUPPERS AND
OVERFLOW SCUPPERS; ALL METALS SHALL BE PRE-FINISHED OR, IF PRE-FINISHED
MATERIAL IS NOT AVAILABLE, PAINTED TO MATCH BUILDING PAINT COLORS.
6. (N) ROOF DRAIN w/ INTEGRAL OVERFLOW INSTALLED AS INDICATED.
7. PROVIDE CHAIN LINK MESH AND SUPPORTING STRUCTURE WITH ADEQUATE
SUPPORT TO ENSURE NO SAGGING INSTALLED HORIZONTALLY OVER EQUIPMENT
ENCLOSURE TO COMPLY WITH CURRENT ANTITERRORISM STANDARDS, UFC
4-010-01 MINIMUM ANTITERRORISM STANDARDS FOR DOD BUILDINGS.
8. APPROXIMATE LOCATION OF VENTILATION HOODS FOR VARIOUS SPACES IN
BUILDING; TYPICAL OF (6) SHOWN; ADDITIONAL VENT HOODS MAY BE REQUIRED;
PROVIDE EQUIPMENT COMPLIANT w/ HVAC STANDARDS ON G001.
9. LOUVERED ATTIC VENTILATION OPENING; SIZE TO BE CALCULATED AS REQUIRED
BY INTERNATIONAL BUILDING CODE; TYPICAL OF (14) SHOWN.
10. 30"w x 36"h ATTIC SPACE ACCESS DOOR; TYPICAL OF (2) SHOWN.
11. REPLACE ALL ROOF ACCESS HATCHES WITH SAME SIZE ACCESS DOORS; FIELD
VERIFY QUANTITY AND LOCATION TYPICAL.
12. REFRIGERATOR (NOT IN CONTRACT); PROVIDE 36"w BY 68"h CLEAR SPACE AS
SHOWN.
13. DRAWER BANK TYPICAL; PROVIDE (4) DRAWERS AS SHOWN.
14. PROVIDE CABINET WITH DOORS AND FIXED DRAWER PANEL AT SINK AREA.
15. PROVIDE CABINET WITH DOORS, FIXED DRAWER PANEL AND FIXED SHELF AT
RANGE AREA.
16. PROVIDE SOLID MATERIAL COUNTERTOP (CORIAN OR EQUIVALENT) AT +36" AFF
TYPICAL WITH MINIMUM 4" BACKSPLASH AT ALL COUNTERTOP AREA TYPICAL.
17. PROVIDE MICROHOOD CONVECTION OVEN COMBINATION; KENMORE ELITE
86013;VENT RANGE HOOD TO SHAFT PROVIDED; PROVIDE MINIMUM CLEARANCE
AS REQUIRED BY MANUFACTURER.
18. PROVIDE FULL OVERHEAD CABINET OVER MICROHOOD CONVECTION OVEN
WITH FIXED SHELF AS SHOWN; SIZE ACCORDING TO REQUIRED CLEARANCES AND
MINIMUM DUCT SIZING FOR HOOD.
19. PROVIDE FULL OVERHEAD CABINET WITH FIXED SHELF OVER SINK AREA WITH
BUILT-IN CONCEALED LIGHT FIXTURE UNDER CABINET; PROVIDE MINIMUM
CLEARANCE.
20. PROVIDE FULL OVERHEAD CABINET WITH (2) FIXED SHELVES AS SHOWN TYPICAL;
B.O. OF CABINET AT +18" ABOVE COUNTERTOP TYPICAL.
21. PROVIDE FULL OVERHEAD CABINET AS SHOWN TYPICAL; SIZE SET BY CLEARANCES
REQUIRED BY REFRIGERATOR (SEE NOTE 12).
22. OPEN TO BEYOND.
23. PROVIDE (3) EQUAL CABINETS WITH FIXED SHELF OVER AREA FOR WASHER AND
DRYER; SET BOTTOM OF CABINETS AT MINIMUM OF 68" AFF TYPICAL.
24. PROVIDE CABINET WITH DOOR AND DRAWER AS SHOWN TYPICAL.
25. WASHER AND DRYER (NOT IN CONTRACT); PROVIDE MINIMUM 60" CLEAR AREA
AS SHOWN.
26. 36" x 48" FIBERGLASS SHOWER PAN WITH CERAMIC TILE SURROUND AND
TEMPERED GLASS SHOWER ENCLOSURE; SHOWER CURB TO BE A MINIMUM OF 4"
TYPICAL; SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.
27. DRAWER BANK TYPICAL; PROVIDE (3) DRAWERS AS SHOWN.
28. PROVIDE CABINET WITH DOOR AND FIXED DRAWER PANEL AT SINK AREA.
29. PROVIDE A FULL WIDTH MIRROR ABOVE THE VANITY, WITH TOP OF MIRROR A
MINIMUM OF 72" ABOVE THE FINISH FLOOR; BOTTOM OF THE MIRROR SHALL
EXTEND TO THE TOP OF THE BACK SPLASH.
30. PROVIDE SOLID MATERIAL COUNTERTOP (CORIAN OR EQUIVALENT) AT +30" AFF
TYPICAL WITH MINIMUM 4" BACKSPLASH AT ALL COUNTERTOP AREA TYPICAL.
31. LOW FLOW TOILET TYPICAL; SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.
KEY PLAN 65
13123
13121
0 13
SCALE: NOT TO SCALE
NORTH
PROJECT
SEE TYPICAL MODULE FLOOR PLAN FOR
TYPICAL NOTES. ALL NOTES SHOWN ON THIS
DRAWING ARE NOT TYPICAL.
SEE TYPICAL MODULE FLOOR PLAN FOR
TYPICAL NOTES. ALL NOTES SHOWN ON THIS
DRAWING ARE NOT TYPICAL.
TYPICAL NOTES 55
A. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH REQUIREMENTS AS
OUTLINED IN UFC 4-010-01/02 MINIMUM ANTITERRORISM STANDARDS FOR DOD
BUILDINGS.
B. PROVIDE APPROPRIATE HVAC SYSTEM AS REQUIRED PER THE FOLLOWING:
-- UFC 3-400-01 ENERGY CONSERVATION
-- UFC 3-401-01FA UTILITY MONITORING & CONTROL SYSTEMS
-- UFC 3-410-01FA HVAC
-- ETL 04-3 : DESIGN CRITERIA FOR PREVENTION OF MOLD IN AF FACILITIES
-- UNACCOMPANIED HOUSING GUIDE, US AIR FORCE
C. SEE FINISH, DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION.
D. INSTALL SPRINKLER FIRE PROTECTION SYSTEM THROUGHOUT FACILITY COMPLIANT
WITH NFPA REQUIREMENTS.
E. CONTRACTOR SHALL PATCH AND REPAIR ALL CONCRETE SLABS TO BE
STRUCTURALLY SOUND WHERE (E) UTILITY CHASES ARE REMOVED AND NOT USED.
F. ALL NEW COMMUNICATIONS WIRING, PANELS AND EQUIPMENT TO INCLUDE
TELEVISION CABLE, TELEPHONE, WI-FI WIRING AND ALARM PANEL WIRING SHALL
MEET CURRENT STANDARDS AS DETERMINED BY 30 SPACE COMMUNICATIONS
SQUADRON.
G. ALL INTERIOR WALLS AND INFILL PANELS SHALL CONTAIN A MINIMUM OF R-19
SOUND INSULATION TYPICAL.
42SCHEMATIC INTERIOR ELEVATIONS
SCALE: 1/4" = 1'-0"
KITCHEN AND LAUNDRY (TYPICAL) BATHROOM - 209A BATHROOM - 209B
(209D SIMILAR) (209C SIMILAR)
BEDROOM
310A
169.4 SF
BEDROOM
310B
164.7 SF
BEDROOM
310C
164.7 SF
BEDROOM
310D
169.4 SFKITCHEN
LAUNDRY
BATH
BATH
BATH
BATH BATH
BATHBATH
BATH
KITCHEN
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
BEDROOM
309A
169.4 SF
BEDROOM
309B
164.7 SF
BEDROOM
309C
164.7 SF
BEDROOM
309D
169.4 SF
PATIO PATIO
LAUNDRY
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
A301
A301
5 5
A301
A301
NORTH
PROJECT
NORTH
TRUE
26 27 2728 28 26
31 3112 13 14 15
NORTH
PROJECT
NORTH
TRUE