B419 Asbestos and LBP Addendum 2017.pdf

PDF 1 MB Posted

Attached to
Repair Munitions Facility B419 Federal contract opportunity
Solicitation number
FA441820R0010
Issued by
Department of the Air Force Air Mobility Command

About this file

This document includes an addendum to an asbestos assessment report and information on a federal contract opportunity for repair work. The asbestos assessment addendum reports results from sampling ventilation flues and a boiler stack on the south roof section of Building 419 at Joint Base Charleston, finding no asbestos present. The federal contract opportunity is a firm-fixed-price contract with the Department of the Air Force for repair work at Munitions Facility B419 at Joint Base Charleston, with a performance period of 450 calendar days. A pre-bid site visit is scheduled for May 7, 2020 at 9:00am EST at the base visitor center.

View the file

Other files for this federal contract opportunity

Other files attached to Repair Munitions Facility B419, newest first.
File Type Posted
Site Visit Roster B419 FA441820R0010 20200507.pdf PDF
B419 Q and A 1 FA441820R0010 20200519.pdf PDF
B419 As Built Drawings.pdf PDF
Add 1 3a. HERCULES_BiParting_Electric_Submittal_Drawing_v2_USA_FA441820R0010 B.419.pdf PDF
Add 1 1b. Addendum 1 Dwg 28 of 70 A600 Door Schedule and Frame Elevations REV02 FA441820R0010 B.419.pdf PDF
Add 1 1a. 01 of 70_T001_Title Sheet_FA441820R0010_B.419.pdf PDF
17 SPECS 419-Combined-Rev 2020-02-27.pdf PDF
07 Lead-Asbestos Report NOV 2016.pdf PDF
Add 1 1c. Addendum 1 Dwg 52 of 70 - M101 - First Floor HVAC Ductwork Renovation Plan REV01 Fm ADC Eng Dtd 2020_FA441820R0010 B.419.pdf PDF
Add 1 2a. 15321.TOC_Addendum 1_FA441820R0010 B.419.pdf PDF
17 Drawings B 419-R1-2017-08-25.pdf PDF
Add 1 3b. HERCULES_Tech_Spec_Brochure_BiParting_Sliding_Door_FA441820R0010 B.419.pdf PDF
SC20190022 Wage Determination 20200103.pdf PDF
Add 1 FA441820R0010 B.419 2020043002.pdf PDF
Add 1 2c. Addendum 1 Spec Section 08 13 73 FA441820R0010 B.419.pdf PDF
06 Green Procurement Form.pdf PDF
Add 1 4a. 15 AF 66-R1 FA441820R0010 B.419.xlsx XLSX spreadsheet
Add 1 2b Addendum 1 Spec Section 07 84 00 FA441820R0010 B.419.pdf PDF
Solicitation - FA441820R0010 2020043002.pdf PDF
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S&ME, Inc. | 620 Wando Park Boulevard | Mt Pleasant, SC 29464 | p 843.884.0005 | f 843.881.6149 | www.smeinc.com

May 26, 2017

ADC Engineering

1226 Yeamans Hall Road

Hanahan, South Carolina 29410

Attention: Mr. Greg Jones, P.E.

gregj@adcengineering.com

Reference: Addendum to Limited Asbestos and Lead-based Paint Assessment Report

Dated November 23, 2016

Joint Base Charleston (NWS) - Building 419

Goose Creek, South Carolina

S&ME Project No. 4213-16-225

Dear Mr. Jones:

S&ME, Inc. (S&ME) is pleased to provide this addendum to the referenced report summarizing the asbestos assessment we performed at the referenced site on May 23, 2017, limited to the South roof section of the referenced facility. Our services were performed in general accordance with S&ME

Proposal No. 42-1601039, dated September 16, 2015 and additional request to Jim Killingsworth (S&ME) on May 18, 2017. The following sections include the project background, sampling and analysis procedures, findings and results, and conclusions and recommendations, as necessary.

Project Background

On May 18, 2017, you contacted Mr. Jim Killingsworth (S&ME) by telephone and requested an asbestos assessment of ventilation flues and a boiler stack located on the South roof section of Building 419 located at the referenced site. On May 23, 2017, Bill Seaborn and Tony Prioleau of S&ME performed the assessment and sampling.

This report should be used in conjunction with the Limited Asbestos and Lead-Based Paint Assessment

Report dated November 23, 2016 and prepared by S&ME. The purpose of this assessment was to assess, identify, and provide recommendations to properly treat asbestos containing materials (ACMs) associated with the specific components located on the South section of the roof, to prevent worker exposures, emissions and properly dispose of the subject materials, prior to renovation activities.

The subject roof section is a flat built-up system which was reportedly replaced within the last three months of the date of this report. Only the flashing materials associated with the ventilation flues and boiler stack were included as part of this assessment. No built-up roofing materials were sampled.

Limited Asbestos Assessment Addendum Report

Joint Base Charleston (NWS) Building 419

Mary 26, 2017 2

Procedures

A sampling strategy was developed to provide representative samples in accordance with the South

Carolina Department of Health and Environmental Control (SCDHEC) and the Environmental Protection

Agency (EPA). Bulk samples of suspect ACMs were collected by a SCDHEC licensed inspector. The bulk samples were extracted from suspect ACMs, recorded on a chain of custody record and submitted to our in-house Polarized Light Microscopy (PLM) laboratory. Confirmation of negative results by Transmission

Electron Microscopy (TEM) was performed by EMSL Analytical for those non-friable organically bound materials reported negative via PLM. The laboratories are located in Charlotte, North Carolina and both are accredited by the National Voluntary Laboratory Accreditation Program (NVLAP), which is administered by the National Institute of Standards and Technology.

Findings and Results

The asbestos assessment performed on May 23, 2017, limited to the ventilation flues and boiler stack on the South section of the roof of the referenced building, included the assessment and bulk sampling of flashings and mastic.

Based on the results of the bulk samples collected, no asbestos was detected. The EPA and the

Occupational Safety and Health Administration (OSHA) defines a material as asbestos containing if an asbestos content greater than one percent (>1%) is detected in a representative sample.

A summary of asbestos results is provided in Appendix I, and exhibits the sample number, location, type of material tested, approximate quantity of the material sampled, condition of the material, and corresponding result for each sample. Diagrams of bulk sample locations are provided in Attachment II, and a copy of the inspector’s SCDHEC license is provided in Attachment III. A copy of the laboratory analyses and chain-of-custody records are provided in Attachment IV.

Limitations

The asbestos assessment and testing was limited to the specific suspect ACMs in the specific area of the roof of the building, and did not include an assessment of all suspect ACMs associated with the entire roof of the building. The sampling was performed by observing and sampling suspect ACMs associated with the referenced area, and the possibility exists that suspect materials were undetected in inaccessible areas such as roofing overlays and roof voids/cavities.

This report is provided for the sole use of the client. Use of this report by any other parties will be at such party's sole risk and S&ME disclaims liability for any such use or reliance by third parties. The results presented in this report are indicative of conditions only during the time of the sampling and of the specific areas referenced.

Conclusions and Recommendations

Based on the results of the limited asbestos assessment performed on May 23, 2017, of the ventilation flues and boiler stack on the South section of the roof of Building 419 located at Joint Base Charleston

(Naval Weapons Station) in Goose Creek, South Carolina, no ACMs were identified. This report should be used in conjunction with the Limited Asbestos and Lead-Based Paint Assessment Report dated November

Limited Asbestos Assessment Addendum Report

Joint Base Charleston (NWS) Building 419

Mary 26, 2017 3

23, 2016, and prepared by S&ME. If suspect ACMs not addressed in this report are discovered during the planned renovations, the suspect ACM(s) must be sampled by a SCDHEC licensed inspector and analyzed for asbestos content prior to disturbance of the material. This report should also be provided to the contractor(s) working in the referenced area(s).

Closing

S&ME appreciates the opportunity to provide you with our industrial hygiene services and we look forward to our continued association. If you have any questions concerning the results, please call either of us at (843) 884-0005.

Sincerely, S&ME, Inc.

William R. Seaborn Kenneth R. Warren, CIH

Staff Professional Principal Industrial Hygienist, V.P.

Attachments

– Summary of Asbestos Results

Summary of Asbestos Results

Building 419 - Joint Base Charleston NWS

Goose Creek, South Carolina

S&ME Project No. 4213-16-225

Date of Sampling: May 23, 2017

Sample No. Location Material Approx.

Quantity

Asbestos

Type Percent Condition

Potential for

Disturbance

Hazard

Assessment

419-RM-01 South Roof Section - Vent Flue ND NA NA NA NA

419- RM-02 South Roof Section - Boiler Stack ND NA NA NA NA

419-RM-03 South Roof Section - Vent Flue ND NA NA NA NA

419- RF-01 South Roof Section - Vent Flue ND NA NA NA NA

419- RF-02 South Roof Section - Boiler Stack ND NA NA NA NA

419-RF-03 South Roof Section - Vent Flue ND NA NA NA NA

ND = No Asbestos Detected LPD = low potential for disturbance G = good F = friable

NA = Not Applicable PD = potential for disturbance

SF = square feet PSD = potential for significant disturbance EA = each

LF = linear feet

EPA, SCDHEC and OSHA defines a material as asbestos containing if an asbestos content greater than one percent (>1%) is detected in a representative sample.

Quantities are estimated, and should not be used for bidding purposes, as field conditions should be verified.

Samples analyzed by TEM to confirm negative results reported by PLM analysis.

SD = significantly damaged

Flashing 65 LF

Table I: Summary of Asbestos Results

Mastic (silver) associated with flashing

65 LF

D = damaged NF = non-friable

– Diagram of Bulk Sample Locations

BULK SAMPLE LOCATION

LEGEND

419-XX-XX

NOTE: NO ASBESTOS WAS DETECTED IN THE BULK

SAMPLES COLLECTED AND ANALYZED.

419-RF-01

419-RM-01

419-RM-02

419-RF-02

419-RM-03

419-RF-03

AREA INCLUDED IN ASSESSMENT

SCALE:

PROJECT NO.

DRAWN BY:

DATE:

APPROVED BY:

FIGURE NO.

Q d r a w i n g s

B l d g d w g

LIMITED ASBESTOS ASSESSMENT

BUILDING 419 ROOF

JOINT BASE CHARLESTON - NAVAL WEAPONS STATION

GOOSE CREEK, SOUTH CAROLINA

AS SHOWN LAJ

4213-16-225 5-26-2017

00 20' 40'

– Copy of Inspector’s SCDHEC License

S&ME, INC. / 620 Wando Park Blvd. / Mt. Pleasant, SC 29464 / p 843.884.0005 / f 843.881.6149 / www.smeinc.com

South Carolina

Department of Health and Environmental Control

Asbestos License

William Seaborn

Air Sampler AS-00416 Building Inspector BI-01317

S&ME, INC. / 620 Wando Park Blvd. / Mt. Pleasant, SC 29464 / p 843.884.0005 / f 843.881.6149 / www.smeinc.com

South Carolina

Department of Health and Environmental Control

Asbestos License

Antonio Prioleau

Air Sampler AS-00494 Building Inspector BI-01544

– Laboratory Analysis Results and Chain of

Custody Records

Charleston Branch 620 Wando Park Blvd.

Mt. Pleasant SC 29464

Asbestos Analysis Summary

Client Job

Client Name

Date Analyzed

Date Received

5/24/2017

5/24/2017

Naval Weapons Station Bldg 419

9771D Southern Pine Boulevard

Charlotte, NC 28273

704-940-1830 Fax 704-565-4929

NVLAP Lab Code 102075-0

POLARIZED LIGHT MICROSCOPY

Performed by EPA 600/R-93/116 Method

Non-Asbestos Fibrous Non-Fibrous

Lab ID: Sample #: Appearance %/Type

Job Number 4213-16-225

Asbestos Comments %/Type %/Type

2 CELLULOSE 98 OTHER17-4859 419-RM-01 SILVER FIBROUS ND

2 CELLULOSE 98 OTHER17-4860 419-RM-02 SILVER FIBROUS ND

10 SYNTHETIC

5 CELLULOSE

85 OTHER17-4862 419-RF-01 BLACK FIBROUS ND

20 SYNTHETIC 80 OTHER17-4863 419-RF-02 BLACK FIBROUS ND

For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not

Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.

The sample may not be fully representative of the larger material in question. This sheet may not be reproduced except with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion Staining)

(Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None Detected" for these materials is recommended.

Analyzed by: Jane Wasilewski Jane Wasilewski Laboratory ManagerAdditional Comments:

EMSL Analytical, Inc.

376 Crompton Street Charlotte, NC 28273

Tel/Fax: (704) 525-2205 / (704) 525-2382 http://www.EMSL.com / charlottelab@emsl.com

EMSL Order: 411704065

Customer ID: SMEI54

Customer PO:

Project ID:

Attention: Jane Wasilewski Phone: (704) 940-1830

S&ME, Inc. Fax: (704) 565-4929

9771D Southern Pine Blvd. Received Date: 05/24/2017 12:20 PM

Charlotte, NC 28273 Analysis Date: 05/25/2017

Collected Date:

4213-16-225Project:

Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via

EPA/600/R-93/116 Section 2.5.5.1

Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types

419-RM-03

411704065-0001

Silver Mastic Only Silver

Non-Fibrous

Homogeneous

98.9 Fibrous_Other No Asbestos Detected1.1

419-RF-03

411704065-0002

Flashing White/Black

Fibrous

Homogeneous

100 None No Asbestos Detected

Analyst(s)

Aaron Hartley (2) Lee Plumley, Laboratory Manager or other approved signatory

This laboratory is not responsible for % asbestos in total sample when the residue only is submitted for analysis. The above report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical , Inc. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.

Samples analyzed by EMSL Analytical, Inc. Charlotte, NC

Initial report from: 05/25/2017 11:23:00

ASB_PLMEPANOB_0012_0002 Printed 5/25/2017 11:23:07AM Page 1 of 1

OrderID: 411704065