Attch 2 - Drawings 20200529.pdf

PDF 29 MB Posted

Attached to
Repair Interiors 505 TRS and 705 TRS, Bldg 90021
Solicitation number
FA441720R0015
Issued by

About this file

This federal contract opportunity solicitation seeks bids for repair and interior construction work at Building 90021 for the Department of the Air Force Special Operations Command. The solicitation number is FA441720R0015 and involves partial demolition and new construction on the first and second floors of the existing south end warehouse. On the first floor, work includes new bathrooms, a mechanical room, classrooms, labs and support spaces along with partial demolition of the existing warehouse floor slab for plumbing and foundation support of the new second floor deck above. The second floor demolition includes partial removal of the existing mezzanine area for tie in of the new second floor slab. New second floor work comprises partial renovation of existing areas and new construction allowed by installation of the floor slab above, including breakrooms, bathrooms, a mechanical room, offices, classrooms, training conference rooms and other supporting spaces. Additional work involves a prefabricated metal stairway with precast treads and landings on the south side of the existing building along with new penetrations through interior and exterior walls.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P

O

O

L

P O

O

L

P

O

O

L

P

O

O

L

P O

O L

MARY ESTHER, FLORIDA

91065

90527

9915799156

31022

31022

90639

91006

91158

91131

91129

99901

99902

90395

90080

91362

99147

90523

90209

90108

90580

90581

91404

99326

90727

90800

90536

90534

91157

91107

91168

90306

90905

90917

99958

91059

91058

90086

90311

90508

90500

90611

90730

30041

90083

90356

90364

99103

90524

99121

90626

90749

90757

90813

91041

91263

91264

92478

92479

90351

90363

90360

90512

90513

90513

90512

29077

29077

91043

91038

90005

90734

90581

90534

29073

29073

90396

90396

29075

29075

29075

29075

91124

91149

93605

90379

90380

90507

91101

90506

92547

90628

99154

99077

90021

90503

91537

92557

90414

90209

92540

90038

90427

90412

90502

99009

93576

90710

91141

93318

99005

92418

91625

90221

90433

90228

99049

90612

90065

90349

92536

93357

90425

92509

92485

90059

90067

91262

91259

92500

93405

90408

92031

92078

92075

90020

90028

90421

90206

90630

91113

91258

93701

90332

91042

91136

90060

92077

90010

91126

90708

90812

91302

92564

93621

90113

93333

93332

92439

90700

90758

92531

93346

90428

92276

92108

90002

92552

91153

92542

91041

90353

90640

90501

93530

92049

93565

90718

92066

92507

90322

91250

90603

90231

92408

92465

90829

91049

90135

92096

92442

91013

93454

90712

92463

92101

90420

99065

93626

90519

92073

92003

92002

92020

90029

91257

92018

90055

92467

93464

92402

90323

90407

90367

90050

90551

92086

90220

90310

90755

90034

91144

92468

90816

99141

92440

92525

91021

90423

91028

90057

90061

90066

90638

90553

91260

93437

90625

92517

90624

91036

92508

92459

93413

91268

92074

92106

92104

92041

92053

92056

92070

92524

92535

92506

92543

92097

92067

90404

90720

90632

92045

90203

91114

91119

91538

93640

90431

90838

99098

91033

92401

91000

90079

92444

90331

92511

90517

90705

92092

90117

92530

92445

91147

90343

93549

93301

92545

93461

92523

91515

91024

91027

92433

92518

91361

92473

99031

92521

90140

90402

93476

92544

93429

92063

92088

91370

90518

90036

90417

91020

92062

99126

91351

99019

92562

99158

91365

91603

91025

90926

93432

91601

91120

92466

90505

91035

93421

90074

90073

90039

93637

93389

92539

92036

92012

90213

92044

91500

99117

91266

92428

92460

93566

91310

91135

91106

90329

92503

90109

90763

90418

90714

93541

99010

90361

92047

90810

90627

90823

92514

93325

92555

92083

90742

93349

91164

91052

90368

92095

99137

92533

92038

93398

90833

90081

91325

91360

91007

90743

90811

91156

90916

92079

92425

92400

92015

92407

91099

92527

90601

93510

93309

92054

90070

90111

90357

90023

92471

92441

90102

93304

93317

93354

90911

91145

90076

92556

91152

91030

91132

91034

92033

92450

92502

99146

99094

90729

91057

99053

92103

90387

90381

91161

92515

92446

92025

92464

90951

91162

90052

92529

93501

92014

90134

90613

92537

93493

93629

90362

99004

90141

93517

90037

92064

90392

90629

93397

90069

90068

99041

91510

99057

90388

92424

91112

90523

91133

92094

90409

90430

90711

92048

93368

93485

90577

90075

90340

99020

99048

99090

99104

92541

92516

99150

99535

92501

92463

92419

92426

90330

91154

92089

90747

90509

90522

93538

92505

99058

92023

91032

92034

99067

91546

90210

92005

99024

99025

99051

99127

99719

99718

99717

99716

99023

90609

90085

92461

92009

90511

92434

93445

93608

91122

90724

92051

92008

92001

92549

90626

92435

93453

90327

93645

92548

90701

92553

93365

91330

90809

90432

92437

91105

93596

90580

93650

93444

91103

93586

91104

90413

92087

92522

90207

99115

92100

92004

90827

93500

93556

90333

91053

90058

92058

92068

92071

92076

92072

92010

92055

90056

93486

93373

90817

90230

91146

93522

92026

92027

92040

90436

90377

90054

90642

90223

90001

93581

91012

92022

90378

92451

93573

92452

90606

91155

92436

91054

90145

90717

92030

92032

90731

90328

92069

92024

90084

90005

93509

92455

92528

90703

92000

92013

91252

91055

99043

90802

91037

92011

91140

91023

91151

92430

90759

92420

92275

90801

91031

90121

92039

92432

90015

91009

91039

90635

99068

90928

90616

90105

92406

93477

90615

92035

92052

90707

90229

93613

90760

90049

92082

92061

92538

90337

91130

91363

90410

91350

91050

90334

92050

92090

93381

93341

90950

99162

99001

90131

99060

90552

91016

99105

99007

99083

99055

99056

90390

99044

99126

99145

99022

90825

90358

92098

90347

91163

92102

90008

91300

90339

92105

90621

99059

92099

99116

90048

92084

92546

90300

91142

92107

92016

92017

90419

92551

92037

92043

92042

92057

92513

91137

92059

90617

93653

92080

90215

90382

92404

90232

93386

90302

93414

99142

90510

92091

90521

93557

91520

91255

90702

90033

92438

93597

90935

92065

93422

90369

90532

90619

90035

90208

90618

90128

90822

90748

92472

90137

93469

90371

93618

91029

90352

92060

90138

90063

90806

90525

91047

92021

92019

92028

90326

90438

93589

90713

92403

90064

90370

90115

92519

92449

90426

90062

90636

91045

99030

90051

91254

90304

99500

91056

90366

91364

92429

99042

91303

91148

92093

90880

91301

90815

99118

99029

99061

90225

90416

92046

90439

90053

91265

92085

90030

91400

92550

90716

92427

93542

91159

90359

92469

90032

90106

90637

90325

91307

99045

91048

90761

90101

92081

92431

90600

93660

90434

92007

92006

90308

90043

92470

90918

Tully Street

Kissam Street

M

A

Y

S

T

R

E

E

T

D o w n s

R o a d

W a l k u p

W a y

M a r t i

L t h e r

K n g

D o w n s

R o a d

K a n u h

D i v e

B l e s s i n g i v e

Bartley Street

Mitchell Road

In d e p e n d e n c e

R o a d

T e r y v e n u e

M c

C l e t r e e t

H a r t s r e e t

US98

T u l l r e e t

M a i n t e n a n c

H a

US98

H o w ie lt e y

Lielmanis Avenue

US98

K e r w o o d

R o a d

C o d e n u e

Lukasik Avenue

Tully Street

R

H r a d

H a m b

P a c e

W e s t f a

C r c l e

Bedel Street

T u l l y

S t r e e t

T u l r e e t

B e n n e e n u e

C r u z

A v e n u e

Red Horse Road

C r u z

A v e n u e

Frazier Street

B e n n e t t

A v e n u e

Bedel Street

I n d e p e n d e n c a d

W a l k p y

C o r le w a d

McMilla n Stre et

US98

W e a v e n u e

Schmauss Lane

Hume Drive

Clark Road

Gelshlager Street

Whitbeck Street

C a m p a i g r e e t

Purcell Drive

C o e n u e

US98

In d e p e n d e n c e

R o a d

O N e i l

A v e n u e

US98

McIntosh Court

Hume Drive

H a r r i s i v e

A c h i v e

H u m i v e

Walters Drive

Hodges Street

Lewis Drive

Hume Drive

Galvan Street

Bland Street

Hume Drive

Grimm Lane unk unk

Tully Street

Bakke Street

M a r e e t

Bakke Street

Tupelo Circle

R e d

H o rs e

R o a d

Tully Street

F o x x e n u e

L e t o u r n e r c l e

L e t o u r n e a u

C i r c l e

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

G-001

29 MAY 2020

TI

TL

E

SH

EE

T

JGH

RCR

CP1017959

C O

N S

T R

U C

T

S

N

D

F

L O

O R

T

H

C

B

U I L D

I N

G

REPAIR INTERIORS 505 TRS & 705 TRS

BLDG 90021

HURLBURT FIELD, FLORIDA

CP1017959

NORTH

BASE MAP

PROJECT SITE

HURLBURT MAIN GATE

NO COMMERCIAL ENTRY

FIRE DEPARTMENT

BLDG. 90734

MARTIN LUTHER KING

JR. BLVD INTERSECTION

ENTRANCE

COMMERCIAL VEHICLE

INSPECTION ENTRANCE

PASS & ID OFFICE

HURLBURT EAST GATE, NO

COMMERCIAL ENTRANCE

NORTH

CONTRACTOR

HAUL ROUTE

PLAN

NORTH

TRUE

TRUE

100% SUBMITTAL

CONTRACTOR

LAYDOWN AREA

NORTH

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

M M

SC

O

D

G-002

29 MAY 2020

SH

EE

T

IN

DE

X

JGH

RCR

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

INDEX OF DRAWINGS

SHEET

NUMBER SHEET NAME

INTERIOR

I-120 FIRST FLOOR FINISH PLAN

I-121 SECOND FLOOR FINISH PLAN

I-122 FINISH SCHEDULES

I-123 FINISH DETAILS

I-124 LAB FURNITURE ROOMS 148 AND 149 DETAILS

FIRE PROTECTION

FP-100 FIRE PROTECTION SITE PLAN

FP-101 FIRST FLOOR PLAN - FIRE PROTECTION DEMO

FP-102 SECOND FLOOR PLAN - FIRE PROTECTION DEMO

FP-103 FIRST FLOOR PLAN - FIRE PROTECTION NEW WORK

FP-104 SECOND FLOOR - FIRE PROTECTION NEW WORK PLAN

PLUMBING

P-001 PLUMBING LEGEND, NOTES & ABBREVIATIONS

P-101 FIRST FLOOR PLAN - PLUMBING WASTE AND VENT

P-102 FIRST FLOOR PLAN - PLUMBING WATER

P-103 SECOND FLOOR PLAN - PLUMBING WASTE & VENT

P-104 SECOND FLOOR PLAN - PLUMBING WATER

P-401 ENLARGED FLOOR PLAN AND SECTIONS - PLUMBING

P-402 ENLARGED FLOOR PLAN - PLUMBING

P-501 DETAILS

P-601 SCHEDULES

P-901 RISERS

MECHANICAL

M-001 HVAC LEGENDS, NOTES & ABBREVIATIONS

M-101 SECOND FLOOR PLAN - HVAC DEMO

M-102 FIRST FLOOR PLAN - HVAC NEW WORK

M-103 SECOND FLOOR PLAN - HVAC NEW WORK

M-301 HVAC ENLARGED PLAN AND SECTIONS

M-501 DETAILS-1

M-502 DETAILS-2

M-601 SCHEDULES

M-701 HVAC CONTROLS

ELECTRICAL

E-001 LEGEND, NOTES, RISER DIAGRAM

E-002 PANELBOARD SCHEDULES

E-003 FIRST FLOOR DEMOLITION PLAN

E-004 SECOND FLOOR DEMOLITION PLAN

E-101 FIRST FLOOR LIGHTING PLAN

E-102 SECOND FLOOR LIGHTING PLAN

E-103 FIRST FLOOR POWER PLAN

E-104 SECOND FLOOR POWER PLAN

E-105 FIRST FLOOR FIRE ALARM/MASS NOTIFICATION PLAN

E-106 SECOND FLOOR FIRE ALARM/MASS NOTIFICATION PLAN

E-107 FIRST FLOOR SECURITY SYSTEMS PLAN

E-108 SECOND FLOOR SECURITY SYSTEMS PLAN

E-109 SECURITY SYSTEM DETAILS

TELECOMMUNICATIONS

T-101 FIRST FLOOR TELECOMMUNICATIONS PLAN

T-102 SECOND FLOOR TELECOMMUNICATIONS PLAN

INDEX OF DRAWINGS

SHEET

NUMBER SHEET NAME

GENERAL

G-001 TITLE SHEET

G-002 SHEET INDEX

CIVIL

C-101 SITE UTILITY PLAN

C-201 SITE PLAN

STRUCTURAL

S-001 GENERAL NOTES

S-002 GENERAL NOTES AND WIND LOAD DIAGRAM

S-101 1ST FLOOR DEMOLITION PLAN

S-102 2ND FLOOR DEMOLITION PLAN

S-110 FOUNDATION PLAN - NEW WORK

S-120 2ND FLOOR FRAMING PLAN - NEW WORK

S-130 ENLARGED STAIR PLANS

S-201 WALL ELEVATIONS

S-202 WALL ELEVATIONS & DETAILS

S-301 SECTIONS & DETAILS

S-302 SECTIONS & DETAILS

S-303 SECTIONS & DETAILS

S-401 TYPICAL SECTIONS & DETAILS

ARCHITECTURAL

A-001 LEGENDS AND ABBREVIATIONS

A-002 WALL TYPES

A-110 FIRST FLOOR - EXISTING PLAN

A-111 SECOND FLOOR - EXISTING PLAN

A-112 FIRST FLOOR - PHASING PLAN

A-113 SECOND FLOOR - PHASING PLAN

A-114 FIRST FLOOR - DEMOLITION PLAN

A-115 SECOND FLOOR - DEMOLITION PLAN

A-120 FIRST FLOOR - NOTE PLAN

A-121 FIRST FLOOR - DIMENSION PLAN

A-122 SECOND FLOOR - NOTE PLAN

A-123 SECOND FLOOR - DIMENSION PLAN

A-150 FIRST FLOOR - REFLECTED CEILING PLAN

A-151 SECOND FLOOR - REFLECTED CEILING PLAN

A-201 EXTERIOR ELEVATIONS

A-301 BUILDING SECTIONS

A-401 ENLARGED PLANS AND SECTIONS

A-402 ENLARGED PLANS AND ELEVATIONS

A-403 CASEWORK SECTIONS

A-501 DEMO DETAILS

A-502 DETAILS

A-503 COLUMN DETAILS

A-601 DOOR AND WINDOW SCHEDULE

A-602 DOOR DETAILS

A-603 DOOR DETAILS

A-604 DOOR & WINDOW DETAILS

A-605 FOLDING PARTITION DETAILS

NOT TO SCALE

G-002

1 CONTRACTOR LAYDOWN AREA

E X

F

D

E X

U

P

T

O

B

E L

O

C

O N

D

F L

O O

R

E X ø

S S

E X ø

V

4"øV ø

V

U P

SD

x

SD

x

SD

x

SD

x

SD

x

SD

x

SD

x

SD

x

SD

x

S D x

S D x

S D x

S D x

S D x

W x

W x

W

W W W W

W

W x

W x

W x

W x

W x

W

W W W W

W

W x

W x

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

0 10' 20'

N

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

M M

SC

O

D

C-101

29 MAY 2020

SI

TE

U

TI

LIT

Y

PL

AN

JG

CEB

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

SITE UTILITY PLAN

1" = 10'

EXISTING SANITARY MANHOLE (TH#47)

TOP ELEV = 18.66

N INV = 16.19 (NEW PIPE CONNECTION TO BE CORED)

S INV = 15.94

E INV = 16.12

W INV = 17.02

BEGIN PIPE ADJUSTMENTS

END PIPE ADJUSTMENTS

STORM DRAIN TO REMAIN

KEYNOTES

KEY NOTE:

EXISTING 8" WATER MAIN (FIRE)

EXISTING 3/4" WATER MAIN

EXISTING 10" STORM DRAIN

INSTALL 8" - 45° BENDS WITH MECHANICAL

RESTRAINT

INSTALL 3/4" - 45° BENDS

CORE / BOOT / CONNECT 4" PVC W/ EXISTING

SANITARY MANHOLE

83 LF OF 4" SANITARY

SERVICE LATERAL 4% SLOPE

NEW STAIR TOWER

NOTES:

RUBBER BOOT, DOUBLE BANDED, 316 S/S CLAMPS,

MEETING THE ASTM C923 STANDARD. Kor-N-Seal® I EX

SERIES CONNECTOR WITH DOUBLE STAINLESS STEEL

BANDS OR EQUAL

GRAVITY SEWER CONNECTION

TO EXISTING MANHOLE

NTS

BRICK MANHOLE

CUT PIPE FLUSH TO

EDGE OF INTERIOR WALL

FILL INTERIOR VOID AREAS W/

NON SHRINK GROUT FLUSH W/

INSIDE OF MH

MANHOLE INVERT

FILL ALL EXTERIOR VOIDS AND

ENCAPSULATE ALL EXTERIOR

PARTS OF THE RUBBER BOOT

CREATING A COLLAR W/ NON

SHRINK GROUT

GRAVITY SEWER PIPE

SOLID CLASS "C" CONCRETE W/

SOLID FILLER BRICKS ONLY

ALLOWED AS FILLER NO RUBBLE.

CONCRETE MANHOLE

NOTES:

ONE WEEK PRIOR TO GROUND-BREAKING FOR UTILITIES,

CONTACT THE POINT OF CONTACT BELOW TO SCHEDULE

A GROUNDS SURVEY. (GOPHER TORTOISE SURVEY)

LORRAINE "RAIN" KETZLER

ASSOCIATE WILDLIFE BIOLOGIST

HURLBURT FIELD NATURAL RESOURCES MANAGER

1 SOCES/CEIE

US FISH AND WILDLIFE SERVICE

OFFICE: 850-884-7916

(P) CELL: 850-529-2711

ALL UTILITY LINES TO BE FLUSHED UPON COMPLETION OF

CONNECTION.

CIVIL CONTRACTOR TO COORDINATE UTILITY

ELEVATIONS TO PROVIDE REQUIRED CLEARANCE UNDER

NEW 4" SANITARY LATERAL LINE LEAVING BUILDING. SEE

PLUMBING DETAIL 4, SHEET P-401.

C-101

TWO-WAY CLEANOUT INV=19.5

SEE PLUMBING SHEETS FOR

ADDITIONAL INFORMATION

FFE = 22.00'

REMOVE 5 FT OF EXISTING

CURB AND GUTTER

3 88

4"øV

U P

CJ

EJEJ

EJ

CJ

CJ CJ CJ CJ CJ CJ CJ

0 5' 10'

N

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

C-201

29 MAY 2020

SI

TE

P

LA

N

JG

CEB

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

SITE PLAN

1" = 10'

CONCRETE SIDEWALK DETAIL

NTS

2% CROSS SLOPE

(UNLESS OTHERWISE

SHOWN)

CONTRACTION JOINT EXPANSION JOINT

NOTES:

1. CONTRACTION JOINT EVERY 5 FEET.

2. EXPANSION JOINT EVERY 20 FEET.

4" CONCRETE PAVEMENT W/

6" x 6" W1.4 x W1.4 WWF

4" #57 STONE

1" TY

P

CONCRETE WALK SECTION

1/8" 3,500 PSI JOINT SEALER

PRE-MOULDED EXPANSION

JOINT FILLER CONFORMING TO

ASTM D1751 OR D1752

1/8"

4"

NEW STAIR TOWER

NEW 5' WIDE CONCRETE

SIDEWALK W/ MAX 2% CROSS

SLOPE (AWAY FROM BUILDING)

AND MAX 5% RUNNING SLOPE

REMOVE 5 FT OF EXISTING

CURB AND GUTTER, AND

CONNECT NEW SIDEWALK

FFE = 22.00'

ADJUST EXISTING

CLEANOUT EVEN

WITH SIDEWALK

9'x6' CONCRETE

STOOP, W/ 1%

SLOPE AWAY

FROM DOORWAY

ELEV=21.67

CONTRACTOR TO CONFIRM

STOOP HIGHER THAN

ADJACENT GRADE

C-102

FFE = 22.00

3.75' 5'

8"

V A

R I E

S

FILL EXISTING

GROUND

NON-WOVEN

FILTER FABRIC

(WEED CONTROL)

SOD ALL DISTURBED

AREAS

FA

CE

O F

BU

ILD

IN

G

4 88

1.00 GENERAL NOTES

1.01 THESE STRUCTURAL NOTES SHALL BE APPLIED WITH THE TECHNICAL SPECIFICATIONS IN THE SPECIFICATIONS MANUAL. ANY CONFLICTING REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION

OF THE STRUCTURAL CONTRACTING OFFICER FOR RESOLUTION BEFORE PROCEEDING WITH FABRICATION

OR CONSTRUCTION.

1.02 VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE STARTING WORK. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCY.

1.03 ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE, 2015.

1.04 THE STRUCTURE HAS BEEN DESIGNED UTILIZING THE FOLLOWING REFERENCES:

A. UFC 1-200-01, GENERAL BUILDING REQUIREMENTS

B. UFC 3-301-01, STRUCTURAL ENGINEERING, WITH CHANGE 1

C. INTERNATIONAL BUILDING CODE, 2015

D. ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES

E. ACI 302.1 R-5, CONCRETE FLOOR AND SLAB CONSTRUCTION

F. ACI 318-11, BUILDING CODE REQUIREMENTS FOR CONCRETE STRUCTURES

G. ACI 360 R-06, DESIGN OF SLAB ON GRADES

H. AISC STEEL CONSTRUCTION MANUAL 14TH EDITION

I. ACI 530-11, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES

1.05 DESIGN LOADS

A. DEAD LOADS:

1. MECHANICAL, ELECTRICAL, PLUMBING: 10 PSF

2. CEILINGS AND INSULATION: 5 PSF

B. LIVE LOADS: (MAY BE REDUCED PER CODE)

1. SECOND FLOOR: 60 PSF

2. STAIRS: 100 PSF

3. PARTITIONS: 10 PSF

4. SLAB-ON-GRADE: 100 PSF

C. WIND LOADS - STRUCTURE HAS BEEN DESIGNED TO CONFORM TO THE WIND PROVISIONS OF

ASCE 7-10. SEE WIND PRESSURE DIAGRAM & CHART FOR THE FOLLOWING:

1. BASIC WIND SPEED (3-SEC GUST)

2. BUILDING RISK CATEGORY

3. WIND EXPOSURE CATEGORY

4. INTERNAL PRESSURE COEFFICIENT

5. COMPONENT & CLADDING WIND PRESSURES

1.06 DRAWINGS SHOW TYPICAL AND CERTAIN SPECIFIC CONDITIONS ONLY. FOR DETAILS NOT

SPECIFICALLY SHOWN, PROVIDE DETAILS SIMILAR TO THOSE SHOWN.

1.07 THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.

1.08 CONTRACTOR SHALL MAKE NO DEVIATION FROM DESIGN DRAWINGS WITHOUT WRITTEN APPROVALOF THE CONTRACTING OFFICER. FOR ADDITIONAL OPENINGS NOT SHOWN ON THE STRUCTURALDRAWINGS, SEE ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS. NOTIFY CONTRACTING OFFICER OF ANY

CONFLICT AND/OR OMISSION.

1.09 REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS BY THE CONTRACTING OFFICER OR OTHERS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW AND CHECK SHOP DRAWINGS

BEFORE SUBMITTAL TO THE CONTRACTING OFFICER. THE CONTRACTOR REMAINS SOLELY

RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP

DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS ALSO RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES OF CONSTRUCTION.

2.00 FOUNDATIONS AND SLAB-ON-GRADE

2.01 THE DESIGN OF FOUNDATIONS, RETAINING WALLS AND SLAB ON GRADE IS BASED ON THE CRITERIA ESTABLISHED IN THE GEOTECHNICAL REPORT FOR THE ORIGINAL CONSTRUCTION BY PENSACOLA TESTING LABORATORIES, INC., PENSACOLA, FLORIDA; FILE #02-160, DATED NOVEMBER 27, 2002.

HOWEVER, THE STRUCTURES HAVE BEEN DESIGNED AS PILE-SUPPORTED. THEREFORE, THE

COMPACTION AND DEWATERING REQUIREMENTS UNDER FOUNDATIONS DO NOT APPLY. THIS REPORT IS PROVIDED IN AN APPENDIX TO THE PROJECT SPECIFICATIONS FOR USE BY THE HELICAL PILE

CONTRACTOR.

2.02 SLAB-ON-GRADE REQUIREMENTS:

A. THE SLAB-ON-GRADE SHALL BE A MINIMUM OF 6 INCHES THICK, PLACED ON COMPACTED

SUBGRADE, AND REINFORCED WITH #3@12”.

B. SUBGRADE SHALL BE PREPARED AS RECOMMENDED IN THE GEOTECHNICAL REPORT.

C. SEE SPECIFICATIONS FOR VAPOR RETARDER MATERIAL TO BE PLACED BENEATH INTERIOR

SLABS-ON-GRADE. VAPOR RETARDER SHALL CONFORM TO ASTM E1745, CLASS A, B, OR C AND BE A MINIMUM OF 15 MIL. THICKNESS. THE NEW VAPOR RETARDER SHALL BE LAPPED AND TAPED TO

SPLICE WITH EXISTING VAPOR RETARDER AND SHOULD BE PLACED OVER THE PREPARED

SUBGRADE. TO REDUCE THE POSSIBILITY OF PUNCTURE WHEN THE VAPOR RETARDER IS TO BE

PLACED OVER A ROUGH GRANULAR FILL LAYER, PROVIDE A THIN LAYER OF APPROXIMATELY 1/2

INCH OF FINE-GRADED MATERIAL ROLLED OR COMPACTED OVER THE GRANULAR FILL LAYER

PRIOR TO INSTALLATION OF THE VAPOR RETARDER. VAPOR RETARDER SHOULD BE OVERLAPPED 8 IN.

AND TAPED AT THE JOINTS AND CAREFULLY FITTED AROUND SERVICE OPENINGS.

3.00 REINFORCED CONCRETE

3.01 ALL CONCRETE WORK SHALL CONFORM TO ACI 301-05, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. DESIGN IS BASED ON ACI 318-05, BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. DETAIL CONCRETE REINFORCEMENT AND ACCESSORIES IN ACCORDANCE WITH ACI 315, DETAILING MANUAL. DETAIL ALL CONCRETE WALLS AND BEAMS ON THE SHOP DRAWINGS IN ELEVATION UNLESS SPECIFICALLY APPROVED OTHERWISE. SUBMIT SHOP DRAWINGS FOR APPROVAL, SHOWING ALL FABRICATION DIMENSIONS AND LOCATIONS FOR PLACING REINFORCING STEEL AND ACCESSORIES. DO

NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND REVIEWED.

3.02 UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL BE NORMAL WEIGHT AND HAVE THE FOLLOWING

MINIMUM 28 DAY COMPRESSIVE STRENGTHS:

A. FOUNDATIONS 3000 PSI

B. SLAB-ON-GRADE 3000 PSI

C. FRAMED FLOOR SLABS 4000 PSI

ALL CONCRETE SHALL HAVE ENTRAINED AIR, U.N.O. CONCRETE MAY CONTAIN A PROPERLY

DESIGNED SUPERPLASTICIZER FOR WORKABILITY.

3.03 REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 UNLESS NOTED OTHERWISE.

3.04 THE PROPOSED MATERIALS AND MIX DESIGN SHALL BE FULLY DOCUMENTED AND REVIEWED BY THE CONTRACTING OFFICER. RESPONSIBILITY FOR OBTAINING THE REQUIRED DESIGN STRENGTH IS THE

CONTRACTOR'S.

3.05 USE OF CALCIUM CHLORIDE, CHLORIDE IONS, OR OTHER SALTS IN CONCRETE IS NOT PERMITTED.

3.06 HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED ONLY WHERE INDICATED. THE STRUCTURAL ENGINEER SHALL APPROVE THE LOCATION OF VERTICAL CONSTRUCTION JOINTS. CONSTRUCTION JOINTS SHALL BE THOROUGHLY ROUGHENED BY MECHANICAL MEANS, AND CLEANED. CONTRACTOR

SHALL SUBMIT DRAWINGS SHOWING INTENDED POURING SEQUENCE AND LOCATION OF

CONSTRUCTION JOINT TO THE ENGINEER FOR REVIEW. PROPOSED METHODS MUST BE ACCEPTABLE

TO THE ARCHITECT BEFORE USE.

3.07 CHAMFER OR ROUND ALL EXPOSED CORNERS A MINIMUM OF 3/4".

3.08 TIE ALL REINFORCING STEEL AND EMBEDMENTS SECURELY IN PLACE PRIOR TO PLACING CONCRETE.

PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THE POSITION OF REINFORCEMENT WITHIN SPECIFIED TOLERANCE DURING ALL CONSTRUCTION ACTIVITIES. "STICKING” DOWELS INTO WET CONCRETE IS NOT

PERMITTED.

3.09 PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE; SPLICE ONLY AS SHOWN OR

APPROVED; STAGGER SPLICE WHERE POSSIBLE; USE FULL TENSION SPLICE (CLASS "B") UNLESS NOTED OTHERWISE. DOWELS SHALL MATCH THE SIZE AND SPACING OF THE SPECIFIED REINFORCEMENT AND SHALL BE LAPPED WITH FULL TENSION SPLICES (CLASS "B") UNLESS NOTED OTHERWISE. TERMINATE BARS WITH

STANDARD HOOKS.

3.10 REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE COVER UNLESS NOTED OTHERWISE

(PER ACI 318-05 PAR.7.7.1):

A. CONCRETE AGAINST EARTH (NOT FORMED): 3"

B. FORMED CONCRETE EXPOSED TO THE EARTH OR WEATHER:

1. #6 THROUGH #18 BARS: 2"

2. #5 BARS AND SMALLER: 1-1/2"

C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER:

1. SLABS AND WALLS: 1"

2. BEAMS (STIRRUPS) AND COLUMNS (TIES): 1-1/2"

3.11 DO NOT PLACE DUCTS EXCEEDING ONE-THIRD THE SLAB OR WALL THICKNESS WITHIN THE SLAB OR

WALL UNLESS SPECIFICALLY SHOWN AND DETAILED ON STRUCTURAL DRAWINGS.

3.12 DO NOT WELD OR TACK WELD REINFORCING STEEL UNLESS APPROVED OR DIRECTED BY THE

STRUCTURAL ENGINEER.

3.13 ALL REINFORCING STEEL PLACEMENTS SHALL BE REVIEWED BY THE CONTRACTING OFFICER, OR BY A

REPRESENTATIVE RESPONSIBLE TO HIM. (RE: ACI 318 PAR. 1.3.1)

3.14 PROVIDE FOR AN ALLOWANCE OF 1% BY WEIGHT OF REINFORCING BARS TO BE FABRICATED, AND

PLACED DURING PROGRESS OF WORK AS MAY BE DIRECTED BY THE STRUCTURAL ENGINEER, IN

ADDITION TO ALL THE STEEL INDICATED ON THE DRAWINGS, CREDIT ANY UNUSED QUANTITY AT THE END

OF THE PROJECT.

3.15 FOR CONCRETE PADS SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS.

4.00 STRUCTURAL STEEL, STEEL DECK

4.01 STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED ACCORDING TO AISC

"SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, ASD, LATEST EDITION.

4.02 SUBMIT SHOP DRAWINGS PREPARED IN ACCORDANCE WITH AISC MANUAL "DETAILING FOR STEEL CONSTRUCTION", LATEST EDITION. STEEL FABRICATOR SHALL SUPPLY ANCHOR BOLT LOCATION DRAWINGS. DO NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND REVIEWED.

4.03 STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992. STRUCTURAL STEEL SHAPES, PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36 UNLESS NOTED OTHERWISE. S

TRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B, FY = 46 KSI, UNLESS NOTED

OTHERWISE. STEEL PIPE SHALL CONFORM TO ASTM A501 OR ASTM A53, TYPE E OR S, GRADE B. ANCHOR

BOLTS SHALL CONFORM TO ASTM A36 UNLESS NOTED OTHERWISE.

4.04 BOLTS SHALL CONFORM TO ASTM A325, 3/4-INCH DIAMETER MINIMUM, UNLESS NOTED OTHERWISE.

BOLTS IN BEARING CONNECTIONS SHALL BE DESIGNATED TYPE N, TENSIONED, SNUG-TIGHT AS DEFINED BY AISC. BOLTS IN MOMENT CONNECTIONS AND IN TRUSSES SHALL BE DESIGNATED SLIP-CRITICAL (SC). FULLY TENSION SLIP-CRITICAL CONNECTIONS WITH DIRECT TENSION INDICATOR WASHERS INSTALLED IN

ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION.

4.05 HEADED STUD SHEAR CONNECTORS (INDICATED AS “HS”): ASTM A 108, GRADES 1010 THROUGH 1020, HEADED-STUD TYPE, COLD-FINISHED CARBON STEEL; AWS D1.1, TYPE B. USE AUTOMATIC END

WELDING OF HEADED-STUD SHEAR CONNECTORS ACCORDING TO AWS D1.1 AND MANUFACTURER’S

WRITTEN INSTRUCTIONS.

4.06 USE PRE-QUALIFIED WELDED JOINTS AS PER AISC, AND AWS D1.1 "STRUCTURAL WELDING CODE." USE

ONLY CERTIFIED WELDERS; ALL ELECTRODES SHALL CONFORM TO AWS A5 GRADE E70XX. BARE

ELECTRODE AND GRANULAR FLUX SHALL CONFORM TO AWS A5, F70 AWS FLUX CLASSIFICATION. MINIMUM

WELD SIZE TO BE 3/16" FILLET WELD, U.N.O.

4.07 CUTS, BOLTS, COPING, ETC. REQUIRED FOR WORK OR OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWINGS AND MADE IN THE SHOP. CUTS OR BURNING HOLES IN STRUCTURAL STEEL MEMBERS IN THE

FIELD WILL NOT BE PERMITTED.

4.08 WHEN SPECIFICALLY NOT DETAILED ON THE DESIGN DRAWINGS PROVIDE THE FOLLOWING BEAM

CONNECTIONS:

A. USE TWO-SIDE ANGLE CONNECTIONS PER AISC SPECIFICATIONS, LATEST EDITION.

B. WHERE BEAM REACTIONS ARE SHOWN, CONNECTIONS SHALL DEVELOP THE REACTION GIVEN.

C. WHEN BEAM REACTIONS ARE NOT SHOWN, CONNECTIONS SHALL BE DESIGNED TO SUPPORT ONE HALF THE TOTAL UNIFORM LOAD CAPACITIES SHOWN IN THE ALLOWABLE UNIFORM LOAD TABLES, PARTS 2 OF THE AISC MANUAL, FOR THE GIVEN BEAM, SPAN, AND GRADE OF STEEL SPECIFIED.

D. WHERE REACTIONS ARE SUBJECT TO ECCENTRICITY, SUCH ECCENTRICITY SHALL BE TAKEN INTO

ACCOUNT.

4.09 PROVIDE TEMPORARY BRACING OF STRUCTURAL FRAMING TO PROVIDE LATERAL SUPPORT UNTIL ALL PERMANENT BRACING MOMENT CONNECTIONS AND FLOOR AND ROOF DECKS (DIAPHRAGMS) ARECOMPLETELY

INSTALLED.

4.10 STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL AND MECHANICAL DRAWINGS AND DRAWINGS RELATED TO OTHER TRADES. CONTRACTOR SHALL BE RESPONSIBLE TO CHECK

AND COORDINATE DIMENSIONS, CLEARANCES, ETC. WITH THE WORK OF OTHER TRADES. THE

STRUCTURAL STEEL CONTRACTOR SHALL PROVIDE FRAMING AROUND OPENINGS IN FLOOR AND ROOF SLAB AS

INDICATED IN THE MECHANICAL AND ARCHITECTURAL DRAWINGS.

4.11 COMPOSITE CONSTRUCTION SHEAR CONNECTORS: SOLID FLUXED SHEAR CONNECTORS STUDS AUTOMATICALLY WELDED THROUGH THE METAL DECK AS SHOWN ON THE DRAWINGS AND INACCORDANCE

WITH THE RECOMMENDATIONS OF THE MANUFACTURER (NELSON DIVISION OF TRW OR APPROVED EQUAL).

4.12 ALL STUD WELDING SHALL BE INSPECTED AND FIELD-TESTED. ALL STUDS FAILING THE TEST SHALL BE

REPLACED AT THE CONTRACTORS EXPENSE.

4.13 PAINT STRUCTURAL STEEL IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. DO NOT PAINT STEEL SURFACES TO BE ENCASED IN CONCRETE OR RECEIVE SPRAYED ON FIREPROOFING, CONNECTIONS DESIGNATED AS SLIP CRITICAL, OR TO BE WELDED. STEEL SURFACES RECEIVING AUTOMATICALLY

WELDED SHEAR CONNECTORS STUDS IN THE FIELD SHALL NOT BE PAINTED.

4.14 PRIMER: SSPC-PAINT 25, TYPE I, ZINC OXIDE, ALKYD, LINSEED OIL PRIMER.

STEEL DECKING:

4.15 MATERIAL FOR STEEL DECKING SHALL CONFORM TO ASTM A1008 GRADES 33 AND 40, OR FROM A653. SEE

DRAWINGS FOR STEEL DECK TYPE, GAUGE, YIELD STRENGTH AND SECTION PROPERTIES.

4.16 FLOOR DECK SHALL BE COMPOSITE FLOOR DECK.

4.17 UNLESS NOTED OTHERWISE ALL STEEL DECKING SHALL HAVE A GALVANIZED COATING CONFORMING TO

ASTM A653, G90

4.18 STEEL FLOOR DECK ANCHORAGE (UNLESS NOTED OTHERWISE ON PLANS OR DETAILS):

A. WELDING: ANCHOR STEEL DECKING TO THE SUPPORTING STRUCTURE INCLUDING BEARING WALLS

WITH NOMINAL 5/8 INCH DIAMETER PUDDLE WELDS OR EQUIVALENT, AT ALL EDGE RIBS PLUS

INTERIOR RIBS AT A MINIMUM SPACING OF 24 INCHES. WHERE SHEAR STUDS ARE USED FOR

COMPOSITE CONSTRUCTION, THE STUDS MAY REPLACE THE WELDS.

B. SCREWS: AS AN ALTERNATE TO WELDING, DECK MAY BE ANCHORED TO SUPPORTING STRUCTURE

USING #12-16 X 1.5” HEX WASHER HEAD SCREWS AS MANUFACTURED BY HILTI (OR APPROVED

EQUAL), AT ALL EDGE RIBS PLUS INTERIOR RIBS AT A MINIMUM SPACING OF 24 INCHES.

CONTRACTOR HAS THE OPTION TO USE POWDER ACTUATED FASENTERS BY HILTI (OR APPROVED

EQUAL):

BASE STEEL THICKNESS HILTI P.A.F.

</= 3/8” X-EDN 19 THQ 12

>3/8” X-ENP-19 L15

C. FASTEN SIDE LAPS OF ADJACENT UNITS AT A MAXIMUM SPACING OF 24 INCHES WITH #10 SELF-

TAPPING SCREWS BY HILTI (OR APPROVED EQUAL)..

4.19 PROVIDE DECKING CONTINUOUS OVER 3 SPANS MINIMUM WHERE SUPPORTING STRUCTURE PERMITS.

4.20 STEEL DECKING SHALL BE ERECTED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S

RECOMMENDATIONS

5.00 MASONRY

5.01 CONCRETE MASONRY DESIGN, CONSTRUCTION AND TESTING SHALL CONFORM TO TMS 602/ACI 530.1/ASCE

6-13, SPECIFICATION FOR MASONRY STRUCTURES AND OTHER STANDARDS.

5.02 PROVIDE LIGHTWEIGHT, HOLLOW, LOAD-BEARING CONCRETE MASONRY UNITS (CMU) CONFORMING TO

ASTM C90, UNLESS NOTED OTHERWISE.

5.03 PROVIDE MASONRY CONSTRUCTION WITH MINIMUM COMPRESSIVE STRENGTH, f'm = 1700 PSI.

5.04 PROVIDE TYPE "N" MORTAR IN ACCORDANCE WITH ASTM C270 BY PROPORTION REQUIREMENTS, UNLESS

NOTED OTHERWISE.

5.05 VERTICAL CELLS SHALL BE REINFORCED AS SHOWN IN THE CONTRACT DRAWINGS. VERTICAL REINFORCING SHALL BE CONTINUOUS (LAPPED 48 BAR DIAMETERS MINIMUM AT SPLICES, U.N.O.) AND HELD IN POSITION AT THE TOP AND BOTTOM OF THE GROUT POUR. U.N.O., POSITION VERTICAL REINFORCING

IN THE CENTER OF THE CELL.

5.06 PROVIDE GROUT FOR REINFORCED MASONRY IN ACCORDANCE WITH ASTM C476. GROUT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI UNLESS NOTED OTHERWISE. GROUT SHALL BE FLUID CONSISTENCY. FLUID CONSISTENCY SHALL MEAN THAT CONSISTENCY AS FLUID AS POSSIBLE FOR POURING WITHOUT SEGREGATION OF THE CONSTITUENT PARTS. FILL ALL CELLS BELOW GRADE WITH GROUT. ALL GROUT SHALL BE CONSOLIDATED AT THE TIME OF POURING BY VIBRATING AND THEN RECONSOLIDATED BY AGAIN PUDDLING LATER, BEFORE PLASTICITY IS LOST. WHEN GROUTING IS

STOPPED FOR ONE HOUR OR LONGER, CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE POUR OF

THE GROUT 1-1/2 INCHES BELOW THE TOP OF THE UPPERMOST UNIT.

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

S-001

5 88

29 MAY 2020

GE

NE

RA

L N

OT

ES

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

5.07 PROVIDE HORIZONTAL JOINT REINFORCEMENT COMPLYING WITH ASTM A82, NO. 9 GAUGE OR HEAVIER,ZINC

COATED, PLACED 16 INCHES ON CENTER UNLESS NOTED OTHERWISE.

5.08 PROVIDE RUNNING BONDS WITH VERTICAL JOINTS LOCATED AT CENTER OF MASONRY UNITS IN THE

ALTERNATE COURSE BELOW, UNLESS NOTED OTHERWISE.

5.09 ALL MASONRY UNITS SHALL BE FREE OF EXCESSIVE DUST AND DIRT AT THE TIME THEY ARE LAYED BY THE

MASON.

5.10 ALL REINFORCED HOLLOW UNIT MASONRY SHALL BE BUILT TO PRESERVE THE UNOBSTRUCTED VERTICAL CONTINUITY OF THE CELLS TO BE FILLED. WALLS AND CROSS WEBS IN ALL REINFORCED MASONRY WALLS SHALL BE FULLY BEDDED IN MORTAR. ALL HEAD (OR END) JOINTS SHALL BE SOLIDLY FILLED WITH MORTAR FOR A DISTANCE IN FROM EACH FACE OF THE UNIT NOT LESS THAN THE THICKNESS OF THE LONGITUDINAL FACE SHELLS, BOND SHALL BE PROVIDED BY LAPPING UNITS IN SUCCESSIVE VERTICAL

COURSES.

6.00 POST-INSTALLED ANCHORS

6.01 EXCEPT WHERE INDICATED ON THE DRAWINGS, POST-INSTALLED ANCHORS SHALL CONSIST OF THE FOLLOWING ANCHOR TYPES AS PROVIDED BY HILTI, INC. CONTACT HILTI AT (800) 879-8000 FOR PRODUCT

RELATED QUESTIONS.

a) ANCHORAGE TO CONCRETE

i) ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:

(1) HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HIT-Z ROD PER ICC ESR-3187 OR EQUAL

(2) HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT SYSTEM WITH

HAS-E THREADED ROD PER ICC ESR-3187.OR EQUAL

(3) HILTI HIT-RE 500-V3 EPOXY ADHESIVE ANCHORING SYSTEM WITH HAS-E THREADED

ROD PER ICC ESR-2322 FOR SLOW CURE APPLICATIONS OR EQUAL

ii) MEDIUM DUTY MECHANICAL ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:

(1) HILTI KWIK HUS-EZ AND KWIK HUS EZ-I SCREW ANCHORS PER ICC ESR-3027 OR EQUAL

(2) HILTI KWIK BOLT-TZ EXPANSION ANCHORS PER ICC ESR-1917 OR EQUAL

(3) HILTI KWIK BOLT 3 EXPANSION ANCHORS (UNCRACKED CONCRETE ONLY) PER ICC

ESR-2302 OR EQUAL

iii) HEAVY DUTY MECHANICAL ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:

(1) HILTI HDA UNDERCUT ANCHORS PER ICC ESR 1546 OR EQUAL

(2) HILTI HSL-3 EXPANSION ANCHORS PER ICC ESR 1545 OR EQUAL

b) REBAR DOWELING INTO CONCRETE

i) ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:

(1) HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT SYSTEM WITH

CONTINUOUSLY DEFORMED REBAR PER ICC ESR-3187 OR EQUAL

(2) HILTI HIT-RE 500-V3 EPOXY ADHESIVE ANCHORING SYSTEM WITH CONTINUOUSLY

DEFORMED REBAR PER ICC ESR-2322 OR EQUAL

c) ANCHORAGE TO SOLID GROUTED MASONRY

i) ADHESIVE ANCHORS USE:

(1) HILTI HIT-HY 70 MASONRY ADHESIVE ANCHORING SYSTEM (ICC PENDING).OR EQUAL

(2) STEEL ANCHOR ELEMENT SHALL BE HILTI HAS-E CONTINUOUSLY THREADED ROD OR

CONTINUOUSLY DEFORMED STEEL REBAR OR EQUAL

ii) MECHANICAL ANCHORS USE:

(1) HILTI KWIK HUS-EZ SCREW ANCHOR PER ICC ESR-3056 OR EQUAL

(2) HILTI KWIK BOLT-3 EXPANSION ANCHORS PER ICC ESR-1385 OR EQUAL

d) ANCHORAGE TO HOLLOW / MULTI-WYTHE MASONRY

i) ADHESIVE ANCHORS USE:

(1) HILTI HIT-HY 70 MASONRY ADHESIVE ANCHORING SYSTEM PER ICC ESR-3342 OR EQUAL

(2) STEEL ANCHOR ELEMENT SHALL BE HILTI HAS-E CONTINUOUSLY THREADED ROD OR

CONTINUOUSLY DEFORMED STEEL REBAR OR EQUAL

(3) THE APPROPRIATE SIZE SCREEN TUBE SHALL BE USED PER ADHESIVE

MANUFACTURER’S RECOMMENDATION

6.02 ANCHOR CAPACITY USED IN DESIGN SHALL BE BASED ON THE TECHNICAL DATA PUBLISHED BY HILTI OR SUCH OTHER METHOD AS APPROVED BY THE CONTRACTING OFFICER. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE CONTRACTING OFFICER PRIOR TO USE.

CONTRACTOR SHALL PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY THEIR HAVING AN ICC ESR SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE

TEMPERATURE AND INSTALLATION TEMPERATURE.

6.03 INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGINGAND

IN STRICT ACCORDANCE WITH THE CURRENT ICC ESR.

6.04 ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT ANCHORS AND PROXIMITY OF

ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE

CLEARANCES INDICATED ON THE DRAWINGS.

6.05 EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT WITH SPECIFIC ANCHOR LOCATIONS. UNLESS NOTED ON THE DRAWINGS THAT THE BARS CAN BE CUT, THE CONTRACTOR SHALL REVIEW THE EXISTING STRUCTURAL DRAWINGS AND SHALL UNDERTAKE TO LOCATE THE POSITION OF THE REINFORCING BARS AT THE LOCATIONS OF THE CONCRETE ANCHORS, BY HILTI FERROSCAN, GPR, X-RAY, CHIPPING OR OTHER MEANS.

6.06 ADHESIVE ANCHORS SHALL BE INSTALLED IN CONCRETE HAVING A MINIMUM AGE OF 21 DAYS AT THE TIME

OF ANCHOR INSTALLATION IN ACCORDANCE WITH ACI 318-11 D.2.2.

6.07 INSTALLATION OF ADHESIVE ANCHORS IN HORIZONTAL TO VERTICALLY OVERHEAD ORIENTATION SHALL BE DONE BY A CERTIFIED ADHESIVE ANCHOR INSTALLER (AAI) AS CERTIFIED THROUGH ACI AND IN ACCORDANCE WITH ACI 318-2011 (SECTION D.9.2.2). PROOF OF CURRENT CERTIFICATION SHALL BE

SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL PRIOR TO COMMENCEMENT OF

INSTALLATION.

6.08 PROVIDE SPECIAL INSPECTION FOR ALL MECHANICAL AND ADHESIVE ANCHORS PER THE APPLICABLE

BUILDING CODE AND PER THE CURRENT ICC-ES REPORT FOR THE ANCHOR.

7.00 HELICAL PIERS

7.01 MANUFACTURER’S STANDARD BRACKET SYSTEM, RATED TO SUPPORT THE LOADS INDICATED ON THE DRAWINGS, SHALL BE ATTACHED TO EXISTING FOOTINGS WHERE INDICATED ON THE DRAWINGS. EACH

BRACKET SHALL BE POST-TENSIONED TO ENGAGE THE LOAD, WITHOUT LIFTING THE FOOTING.

7.02 PIERS SHALL BE INSTALLED BY AN AUTHORIZED INSTALLING CONTRACTOR WHO HAS SATISFIED THE CERTIFICATION REQUIREMENTS RELATING TO THE TECHNICAL ASPECTS OF THE PRODUCT AND THE ASCRIBED INSTALLATION TECHNIQUES. PROOF OF CURRENT CERTIFICATION BY THE HELICAL PILE

MANUFACTURER MUST BE PRESENTED.

7.03 ALL WORK AS DESCRIBED HEREIN SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE SAFETY

CODES IN EFFECT AT THE TIME OF INSTALLATION.

7.04 HELICAL PIERS AS SPECIFIED SHALL CONFORM TO THE IBC - INTERNATIONAL BUILDING CODE. AN OFFICIAL EVALUATION REPORT WITH ASSIGNED NUMBER SHALL BE PRESENTED UPON REQUEST TO THE OWNER

AND/OR THEIR REPRESENTATIVE.

7.05 THE HELICAL LEAD SECTIONS AND EXTENSION SECTIONS SHALL BE SOLID STEEL, ROUND CORNERED SQUARE SHAFT, OR ROUND STEEL PIPE SHAFT, OR COMPOSITE STEEL AND GROUT SHAFT CONFIGURED

WITH ONE OR MORE HELICAL BEARING PLATES WELDED TO THE SHAFT.

7.06 ALL PIERS MUST BE CORROSION PROTECTED BY HOT DIP GALVANIZATION.

7.07 INSTALLATION UNITS SHALL CONSIST OF A ROTARY TYPE TORQUE MOTOR WITH FORWARD AND REVERSE

CAPABILITIES. THESE UNITS ARE TYPICALLY POWERED.

7.08 INSTALLATION UNITS SHALL BE CAPABLE OF DEVELOPING THE MINIMUM TORQUE AS REQ'D.

7.09 INSTALLATION UNITS SHALL BE CAPABLE OF POSITIONING THE HELICAL PIER AT THE PROPER INSTALLATION ANGLE. THIS ANGLE MAY VARY BETWEEN VERTICAL AND 5 DEGREES DEPENDING UPON

APPLICATION AND TYPE OF LOAD TRANSFER DEVICE SPECIFIED OR REQUIRED.

7.10 INSTALLATION TORQUE SHALL BE MONITORED THROUGHOUT THE INSTALLATION PROCESS.

7.11 HELICAL PIERS SHALL BE INSTALLED TO THE MINIMUM TORQUE VALUE REQUIRED TO PROVIDE THE LOAD

CAPACITIES SHOWN ON THE PLANS.

7.12 THE APPROPRIATE STEEL NEW CONSTRUCTION LOAD TRANSFER DEVICE SHALL BE USED.

7.13 APPROPRIATE HELICAL PIER SELECTION WILL CONSIDER DESIGN LOAD PLUS SAFETY FACTOR, SOIL PARAMETERS AND THE INSTALLATION TORQUE VS. CAPACITY EQUATION AS PER THE MANUFACTURER'S

RECOMMENDATIONS.

7.14 DESIGN OF HELICAL SCREW PILES AND ANCHORS SHALL BE PERFORMED BY AN ENTITY AS REQUIRED IN ACCORDANCE WITH EXISTING LOCAL CODE REQUIREMENTS OR ESTABLISHED LOCAL PRACTICES. THIS

DESIGN WORK SHALL BE PERFORMED BY A LICENSED PROFESSIONAL ENGINEER.

a a a

1 2 a a a

WIND LOAD DETERMINATION ASSUMPTIONS - INTERNATIONAL BUILDING CODE 2015

ROOF SLOPE

145 C 36 3 ON 12 II ENCLOSED

ULTIMATE DESIGN WIND PRESSURES FOR COMPONENTS AND CLADDING (PSF)

ROOF ZONE 1

ROOF ZONE 2 ROOF ZONE 3

WALL ZONE 4 WALL ZONE 5

O-HANG O-HANG

31.8 -50.4 -87.8 55.1 -59.8 -73.8

50 25.2 -47.2 -71.5 51.0 -55.7 -65.6

22.4 -45.8 -64.4 46.9 -51.5 -57.3

NOTES:

1. FOR EFFECTIVE AREAS BETWEEN THOSE GIVEN ABOVE THE LOAD MAY BE INTERPOLATED,

OTHERWISE USE THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA.

2. THE EDGE STRIP, a = 13.5 FT.

3. PRESSURES SHALL BE APPLIED IN ACCORDANCE WITH THE FIGURE SHOWN ON THIS SHEET.

< 10

> 100

WIND VELOCITY

(MPH)

EXPOSURE

CATEGORY

MEAN ROOF

HEIGHT (FT.)

RISK

CATEGORY

ENCLOSURE

CATEGORY

EFF.

AREA

(SQ. FT)

4. PRESSURES GIVEN ARE ULTIMATE LOADS TO BE USED WITH STRENGTH DESIGN. FOR SERVICE

LOADS TO BE USED WITH ALLOWABLE STRESS DESIGN, MULTIPLY THE PRESSURES BY 0.60.

SEE TABLES 2.3 AND 2.4 IN ASCE 7-10 FOR MORE INFORMATION ON LOAD COMBINATIONS.

-102.7

-102.7

-102.7

-87.8

-71.5

-64.4

31.8

25.2

22.4

31.8

25.2

22.4

-102.7

-102.7

-102.7

55.1

51.0

46.9

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

M M

SC

O

D

S-002

6 88

29 MAY 2020

GE

NE

RA

L N

OT

ES

W

IN

D

LO

AD

D

IA

GR

AM

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

BUILDING SCHEMATIC

F

3.73.7

2.72.7

G

G

J

J

2.9

H

SAW CUT & REMOVE SLAB TO

2'-0" BEYOND NEW FOOTINGS

ON ALL SIDES

SAW CUT & REMOVE SLAB

TO 2'-0" BEYOND NEW

FOOTINGS ON ALL SIDES

SAW CUT & REMOVE 12" CMU

FOR DOOR OPENING. SEE DETAIL.

COORD. SIZE & LOCATION OF

OPENING WITH ARCH.

S-201

S-201

(E)

(E)

(E)

(E)

(E)

11' - 10" 17' - 10"

3" 6'

- 8

26' - 3 1/8" 10' - 0" 7' - 10"

TYPICAL @ SLAB DEMO:

PRESERVE A MIN. OF 8" OF

VAPOR BARRIER @ EDGES OF

DEMO FOR LAP W/ NEW

SAW CUT & REMOVE 12" CMU

FOR DOOR OPENING. SEE DETAIL

COORD. SIZE & LOCATION OF

OPENING WITH ARCH.

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

M M

SC

O

D

S-101

7 88

29 MAY 2020

1S T

FL

OO

R

DE

MO

LIT

IO

N

PL

AN

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

1/8" = 1'-0"

S-101

1 1ST FLOOR DEMOLITION PLAN

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

PLAN

NORTH

SAW CUT & REMOVE 12" CMU

FOR DOOR OPENING. SEE DETAIL.

COORD. SIZE & LOCATION OF

OPENING WITH ARCH. 2.9

3.7 3.7

2.72.7

1 1

F G J

E G JH

CUT & REMOVE EXISTING

METAL DECK/CONCRETE SLAB

TO FACE/CMU

CUT & REMOVE EXISTING

BEAMS TO FACE/CMU

.SAW CUT & REMOVE 8" CMU

FOR DOOR OPENING. SEE DETAIL.

COORD. SIZE & LOCATION OF

OPENING WITH ARCH.

S-201

S-201

S-202

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

S-102

8 88

29 MAY 2020

2N D

FL

OO

R

DE

MO

LIT

IO

N

PL

AN

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

1/8" = 1'-0"

S-102

1 2ND FLOOR DEMOLITION PLAN

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

PLAN

3.7

S-201

F JG

2.7

2.9

(E)

E

3.7

2.7

G JH

HSS6X

6X

1/4

HSS6X

6X

1/4

HSS5X

5X

1/4

HSS5X

5X

1/4

HSS5X

5X

1/4

HSS5X

5X

1/4

S-301

12" CMU INFILL

6" SLAB

6" SLAB

6" SLAB

24" THICK PILE CAP

(TYP. OF 3)

TYP.

2' - 0"

6' - 0"

9'

- 8

6'

- 0

13' - 0"

S-201

EXT. FACE/EXIST.

CMU WALL

26' - 3 1/8" 10' - 0" 7' - 10" 16' - 0 1/2"

(E)

(E)

11' - 10" 17' - 10" 16' - 0 1/2" EXT. FACE/EXIST.

CMU WALL

(E)

(E)

3" 6'

- 8

8'

- 0

5/ 8"

EXT. FACE/EXIST.

CMU WALL

5/

8" 9'

- 1 0 3

/8"

EXT. FACE/EXIST.

CMU WALL

12" SLAB

1 3 /4"

1' - 0 3/8" 11' - 5" EXISTING STORM DRAIN LINE

TO REMAIN. FIELD VERIFY LOCATION.

LOCATE HELICAL ANCHORS TO

AVOID STORM DRAIN.

S-130

3 1 /4"

1'

- 9

1"

1"

3' - 6 1/2" *

8' - 9" *INT. FACE/

CMU WALL

*FIELD VERIFY TO

AVOID EXISTING

STORM DRAIN.

6" MINIMUM THICKNESS SLAB-ON-GRADE REINFORCED WITH #3 @12" E.W., WITH 4" CLR. POSITIVE

SUPPORT FROM BOTTOM OF SLAB. SLAB SHALL BE PLACED OVER A VAPOR BARRIER AND

CAPILLARY BREAK AS INDICATED IN THE GENERAL NOTES SECTION 2.02 ON SHEET S-001.

6" SLAB =

12" SLAB =

= 15 TON HELICAL PILE AT BUILDING. 8 TON HELICAL PILE @ EXTERIOR STAIR FOUNDATION.

12" THICK SLAB-ON-GRADE REINFORCED AS INDICATED ON DRAWINGS.

LEGEND

2.9

T/CONC.

7'-11 1/4"

S-302

S-303

S-302

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

S-110

9 88

29 MAY 2020

FO

UN

DA

TI

ON

P

LA

N

- N

EW

W

OR

K

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

1/8" = 1'-0"

S-110

1 FOUNDATION PLAN

T.O.SLAB REF. ELEV: 0'-0" U.N.O.; REF. EL: 0'-0" = ELEV: XX.XX'

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

1/8" = 1'-0"

S-110

STAIR INTERMEDIATE LANDING

PLAN

E G JH

S-201

2.7

2.9

3.73.7

2.7

F

G J

S-301

W

X5

W

X5

W 8X

W 8X

W

X2

W

X2

W 8X

W 8X

W8X10 W16X26W8X10

W8X10

W8X10

W8X10

W8X10

W10X12

W10X12

W10X12

W10X12 W12X14

W12X14

W12X14

W12X14

W12X14

W12X14

W12X14

W12X14

W10X12

W10X12

W10X12

W10X12

W10X12

W10X12

W10X12

W10X12

L6X4 L6X4 L6X4

L6 X4

W8X28 (E)

W8X28 (E) do do do do do do do do do do do do do do do do do do do do do do do do

8" CMU WALL

BELOW (E)

L6 X4

L6 X4

L6 X4

L6 X4

L6 X4

L6 X4

L6 X4

L6 X4

L6 X4

(6)

(6)

(6)

(7)

(6)

(7)

(6)

(6)

(6) (8)

(8)

(8)

(8)

(8)

(8)

(8)

(8)

(6)

(6)

(6)

(6)

(6)

(6)

(6)

(6)

(6)

(6) (6) 25k 19k

9k9k

9k9k

9k9k

9k9k

10k10k

10k10k

8k8k

8k8k

7k 7k

11k11k

11k11k

11k11k

13k13k

13k13k

13k 13k

13k13k

3k13k8k8k

9k9k

10k10k

10k10k

6k 6k

7k 7k

7k 7k

7k 7k

7k 7k

(4

(4

(4

(4

(5

(5

(3

(3

(5

(8

(8

(8

(8

(8

(8 ) (8

(8

(8

(8

(8 )36 k k k k k k k k

L6X4L6X4L6X4

L6 X4

L6 X4

L6 X4

L6 X4

L6 X4

L6X4

L6 X4

L6 X4

L6 X4

L6 X4

L6 X4

S-301

'-3

6'-

8"

26'-3 1/8" 10'-0" 7'-10"

11' - 10" 17' - 10"

S-301

S-201

(E)

(E)

(E)

8'

- 0

5/ 8"

5/

8" 9'

- 1 0 3

/8" (E)

(E)

16' - 0 1/2" EXT. FACE/EXIST.

CMU WALL

EXT. FACE/EXIST.

CMU WALL

EXT. FACE/EXIST.

CMU WALL

16' - 0 1/2" EXT. FACE/EXIST.

CMU WALL

S-301

Sim

S-301

PRECAST CONCRETE

STAIR TREADS &

LANDING

W 8X

B

EL

OW

S-130

S-301

W 8X

(4

2 3

/4"

W8X24 ABOVE

S-301

S-301

W8X24

P1

S-202 x x x x x

2A

S-301

2A

S-301

Sim

2' - 3 3/4"

1'

- 1

0 3 /4"2' - 3 3/4"

LEGEND:

= 3" TYPE VLI 20 GA VULCRAFT OR EQUIVALENT ( TH=

0.0358 in, I= 0.920 in^4/ft) W/ 3 1/2" CONCRETE COVER (6 1/2"

TOTAL) REINFORCED W/ONE LAYER

WWF 6x6 W2.9 x W2.9.

INSTALLATION/ATTACHMENT:

SUPPORT FASTENERS: PUDDLE WELDS/SHEAR STUDS

SIDELAP FASTENERS: #10 TEK SCREWS

FASTENER LAYOUT: 12" MAX SPACING

SIDE LAP FASTENER @ 24" O.C. TYP.

W18x35

BEAM

SIZE

(20)

NO. OF 3/4" DIA. x

4 1/2" SHEAR STUDS;

(36" O.C. MAXIMUM SPACING)

3/4"

AMOUNT OF

CAMBER

BEAM LEGEND

(E) = EXISTING

P1 = HSS4x4x1/4 POST UP

L6x4 = L6x4x5/16 LLV x

= L3x3 HANGER LOCATION - SEE 4/S301

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

M M

SC

O

D

S-120

10 88

29 MAY 2020

2N D

FL

OO

R

FR

AM

IN

G

PL

AN

NE

W

W

OR

K

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

1/8" = 1'-0"

S-120

1 SECOND FLOOR

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

PLAN

S-302

S-302

S-303

S-201

UP

HS

S1

4X 4X

3/1

HS

S1

4X 4X

3/1 6 24

1 3

/4"

5'

- 2

1 1

/4" 3'

- 0 1/

2"

HSS5X

5X

1/4

HSS5X

5X

1/4

HSS5X

5X

1/4

HSS5X

5X

1/4

HSS5X

5X

1/4

HSS5X

5X 1/4

1' - 0 3/8"

EXT. FACE/CMU WALL

12" THICK CONCRETE SLAB-ON-GRADE

REINF. W/ #6@12" E.W., T&B

10 3/8"

1' - 3 1/2"

9' - 3"

HSS5X5X1/4

HSS5X5X1/4

9" 8' - 11" 10 3/8"

-3/4"

S-303

S-201

EXT. FACE/CMU WALL

HSS14X4X3/16

16'-0"

DN

HS

S1

4X 4X

3/1

DN

HS

S1

4X 4X

3/1

HS

S1

4X 4X

3/1

HS

S1

4X 4X

3/1

HSS14X4X3/16

PRECAST CONCRETE

STAIR TREADS (TYP.)

HSS8X4X3/16

HSS14X4X3/16

HS

S3

X3 X3

/16

HS

S3

X3 X3

/16

HS

S3

X3 X3

/16

HS

S3

X3 X3

/16

HS

S3

X3 X3

/16

2' - 6 1/2"

HSS8X4X3/16

MOMENT SPLICE

7'-11 1/4"

15'-11 1/4"

L2 1/2x2 1/2x3/16

X-BRACING

L2 1/2x2 1/2x3/16

X-BRACING

S-302

S-302

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

M M

SC

O

D

S-130

11 88

29 MAY 2020

EN

LA

RG

ED

S

TA

IR

P

LA

NS

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

1/4" = 1'-0"

S-130

1 ENLARGED STAIR PLAN - 1ST FLOOR

1/4" = 1'-0"

S-130

2 ENLARGED STAIR PLAN - 2ND FLOOR

SLAB ON GRADE

0"

SECOND FLOOR

16' - 0"

E G JH

T/FOOTING

-2' - 0"

NEW

OPENING

(SEE NOTE BELOW)

NEW

OPENING

(SEE NOTE

BELOW)

NEW

12" CMU

INFILL

NEW

12" CMU

INFILL

NOTE: EXISTING 12" CMU WALL IS GROUTED SOLID

& ALL CELLS ARE REINFORCED W/ 2#5.

NO ADDITIONAL REINFORCING IS REQUIRED

@ JAMBS/HEADERS OF THESE NEW OPENINGS.

BOT/STEEL

25' - 8"

T/INT. CMU

26' - 4"

TOP 16":

CIP CONCRETE W/ 2#5 T&B

ALL CELLS GROUTED SOLID

#5@8"*

DOVETAIL TRIANGULAR TIE

@16" O.C. VERTICALLY (TYP.)

#5@8"*

TOP 16":

CIP CONCRETE W/ 2#5 T&B

#4 x16" @16" O.C.

DRILL & EPOXY 4"

INTO EXISTING CMU

*EXTEND VERTICAL BARS TO

8" BELOW EXISTING OPENING HEADER.

3.7 2.72.9

T/FOOTING

-2' - 0"

NEW

OPENING

(SEE NOTE

ABOVE)

NEW

OPENING

(SEE NOTE

ABOVE)

S-301

BOT/STEEL

25' - 8"

T/INT. CMU

26' - 4"

2A

S-301

TOP STAIR

LANDING

15' - 11 1/4"

STAIR SLAB

-3/4"

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

S-201

12 88

29 MAY 2020

W

AL

L E

LE

VA

TI

ON

S

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

1/4" = 1'-0"

S-201

1 WEST ELEVATION

1/4" = 1'-0"

S-201

2 SOUTH ELEVATION

0 2' 4' 8'

SCALE 1/4":1'-0"

1'

16' - 0"

SECOND FLOOR

T/INT. CMU

26' - 4"

EXISTING 8" CMU WALL

EXISTING VERTICAL REINFORCING

@24" O.C. (EXACT LOCATION MAY

VARY FROM THIS ELEVATION)

NEW

OPENING

NEW

OPENING NEW

OPENING

8' - 4" 2' - 1 3/4" 3' - 4" 2' - 4" 6' - 0"

VERIFY DIMENSIONS WITH DOORS PURCHASED. COORD. W/ ARCH.

7'

- 4

7'

- 4

7'

- 0

ASSUMED LOCATION OF

HORIZONTAL REINF.

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

S-202

13 88

29 MAY 2020

W

AL

L E

LE

VA

TI

ON

S

DE

TA

ILS

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

1/2" = 1'-0"

S-202

1 NEW OPENING ELEVATION - INTERIOR WALL

SECOND FLOOR

16' - 0"

EXISTING 12" (NOMINAL) CMU

WALL TO REMAIN

6 1 /2"

EXISTING CMU REINF.

2#5 @8" O.C.

NEW FLOOR DECK

(SEE PLAN)

L6x4 (SEE PLAN)

1 1 /2"

3/4" DIA. EXP. BOLTS

@ 12" O.C. W/ 6" MIN. EMBED. SECOND FLOOR

16' - 0"

6 1 /2"

EXISTING 12" (NOMINAL) CMU

WALL TO REMAIN

EXISTING CMU REINF.

2#5 @8" O.C.

NEW FLOOR DECK

(SEE PLAN)

BEAM (SEE PLAN)

FOR TYPICAL STEEL BEAM

TO CMU CONNECTION,

REFER TO 1/S401

SLAB ON GRADE

0"

SECOND FLOOR

16' - 0"

G

TOP/INT. FOOTING

-1' - 0"

HELICAL PILES

(SEE PLAN)

2'

- 0

NEW CONCRETE PATCH TO MATCH THICKNESS OF

ORIGINAL SLAB - HONOR EXISTING CONTROL JOISTS BY

CONTINUING THROUGH NEW SLAB

HSS COLUMN (SEE PLAN)FOR ANCHOR BOLTS & BASE P,

REFER TO 2/S401

L

SEE PLAN

3" 4"

TYP.

3" CLR.

SEE PLAN FOR

REINF.

SEE DETAILS, SHEET S401,

FOR TYPICAL STEEL

CONNECTIONS

#6@12" E.W. +180 HK. BOT.

SECOND FLOOR

16' - 0"

W8X24

BEAM (SEE PLAN) BEAM (SEE PLAN)

2L 3x

3x 1/4

2L 3x

3x 1/4

2L3x3x1/4 BRACE

WHERE INDICATED ON PLAN

4'

- 0

P3/8"x4"x0'-8"

SHOP WELD TO

W-BEAM (TYP.)

L

3/16

3/16

TYP.

P3/8"x4"L

3/16

3/16

BOT/STEEL

25' - 8"

W8X24

HSS4x4

POST

SEE TYPICAL STEEL

CONNECTIONS

EXISTING 12" (NOMINAL)

CMU WALL

EXISTING CMU REINF.

2#5 @8" O.C.

DO NOT CUT

FOR BEAM TO CMU

CONNECTION, SEE 2/S301

**NOTE: COORDINATE W/

DOOR MANUF. FOR FINAL

BOT. OF STEEL ELEVATION

SECOND FLOOR

16' - 0"

J

W8X24

W8 (SEE PLAN)

HSS4x4 POST

FOR CONNECTION,

SEE 7/S301

GAGE

BEAM

GA

GE

BE

AM

5" 5"

1 1 /2"

7" 1 1

/2"

1 1/2" 1 1/2"

1 1 /2"

1 1 /2"

6" 1 1/2"

P3/4"L

1/4

(6) 3/4" DIA. BOLTS

3/8" STIFFENER PL

SECOND FLOOR

16' - 0"

NEW FLOOR DECK

(SEE PLAN)

EXISTING CMU REINF.

2#5 @8" O.C.L6x4 (SEE PLAN)

3/4" DIA. EXP. BOLTS

@ 24" O.C. W/ 6" MIN. EMBED.

1 1 /2"

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF RC

SPE

C

IA

AN

N

PE

R L O

ATI

O

M M

SC

O

D

S-301

100% SUBMITTAL

14 88

29 MAY 2020

SE

CT

IO

NS

D

ET

AI

LS

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

3/4" = 1'-0"

S-301

1 TYPICAL SECTION THRU 2ND FLOOR

3/4" = 1'-0"

S-301

2 TYPICAL BEAM BEARING ON CMU

PARALLEL TO DECK SPAN PERPENDICULAR TO DECK SPAN

3/4" = 1'-0"

S-301

3 TYPICAL SECTION @ NEW INTERIOR COLUMN

3/4" = 1'-0"

S-301

4 SECTION @ PARTITION WALL SUPPORT

0 3" 6" 1'

SCALE 1-1/2":1'-0"

2'

3/4" = 1'-0"

S-301

5 MOVEABLE PARTITION WALL

SECTION @ 2ND FLOOR

3/4" = 1'-0"

S-301

6 SECTION

1 1/2" = 1'-0"

S-301

7 DETAIL

0 6" 1' 2'

SCALE 3/4":1'-0"

4'

3/4" = 1'-0"

S-301

2A TYPICAL SECTION THRU 2ND FLOOR

SLAB ON GRADE

SECOND FLOOR

16' - 0"

T/FOOTING

-2' - 0"

T/PILECAP

-3' - 0"

INT. LANDING

7' - 11 1/4"

1' - 11"

1 1 /4"

#3@12" + 180 HK.

2#4

S.S. EMBED P3/8"x3"

CONT. W/ 1/2" DIA. DBA

@12" O.C.

L

4 1/2" 8" 2"

S.S. P3/8"x3" E.S. OF

PRECAST TEES W/

1/2" S.S. THRU BOLTS

L

ARCH.

COORD. W/ SLOPE DOWN 1/4"

1/2

TOP STAIR

LANDING

15' - 11 1/4"

STAIR SLAB

-3/4"

BOT./X-BRACING &

L2-1/2X2-1/2X3/16 L2-1/2X2-1/2X3/16

TYPICAL: P3/8"x4"x0'-4"

SHOP WELD TO HSS COLUMN

L

3/16

TYP.

2"

(1) 5/8" DIA. BOLT

INT. LANDING

7' - 11 1/4"

STAIR SLAB

-3/4"

TYPICAL: P3/8"x4"x0'-4"

SHOP WELD TO HSS COLUMN

L

3/16

TYP.

(1) 5/8" DIA. BOLT

L2-1/2X2-1/2X3/16 L2-1/2X2-1/2X3/16

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF R

C

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

S-302

100% SUBMITTAL

15 88

29 MAY 2020

SE

CT

IO

NS

D

ET

AI

LS

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

3/4" = 1'-0"

S-302

1 SECTION

0 6" 1' 2'

SCALE 3/4":1'-0"

4'

3/4" = 1'-0"

S-302

2 ELEVATION @ X-BRACE

HS

CO

LU

MN

(S

EE

P

LA

N)

INT. LANDING

7' - 11 1/4"

15' - 11 1/4"

TOP STAIR

LANDING

INT. LANDING

7' - 11 1/4"

PL

AN

SE

E

HSS14x4 STRINGER

(SEE PLAN)

HSS14x4 STRINGER

(SEE PLAN)

3' - 0 1/2" 14' - 1 1/4" 5' - 2"

L2 1/2x2 1/2x3/16

X-BRACING

L2 1/2x2 1/2x3/16

X-BRACING

STAIR SLAB

-3/4"

BOT./X-BRACING &

HSS3x3

(SEE PLAN)

PRECAST CONCRETE

LANDING

HSS14x4

(SEE PLAN)

TYP. @ EXT. FACE

OF STRINGER:

L3x3x1/4 x0'-6" SHOP

WELD TO STRINGER

(2) 3/4" DIA. x4" EXP.

BOLTS @3" O.C.

1'

- 2

PRECAST CONCRETE

TREADS (TYP.)

1 3 /4"

HSS3x3

(SEE PLAN)

PRECAST CONCRETE

LANDING

HSS14x4 (SEE PLAN)HSS14x4

(SEE PLAN)

HANDRAIL

(SEE ARCH.)

HS

S

CO

LU

MN

(S

EE

P

LA

N)

HS

S

CO

LU

MN

(S

EE

P

LA

N)

HS

S

CO

LU

MN

(S

EE

P

LA

N)

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

SP

EC

IA

L

OP

ER

AT

IO

NS

C

IV

IL

E

NG

IN

EE

R

SQ

UA

DR

ON

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90021

IA

R

E

OF R

C

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

S-303

100% SUBMITTAL

16 88

29 MAY 2020

SE

CT

IO

NS

D

ET

AI

LS

KLM

LJD

CP1017959

C O

N S

T R

U C

T

S

D

F

L O

O R

T

H

C

U I L D

I N

G

3/4" = 1'-0"

S-303

1 SECTION

0 6" 1' 2'

SCALE 3/4":1'-0"

4'

W-SHAPE BEAM TO MASONRY WALL CONN., U.N.O.

W-SHAPE BEAM;

SEE PLAN

1/4"

T/BEAM

SEE PLAN

(2) L3 1/2x3 1/2x5/16 W/MAX

NUMBER OF 3/4" DIA. BOLTS IN

SHORT SLOTTED HOLES; TYP.

1/2" RET.

T&B; TYP.

W8 BEAM W10 BEAM W16 BEAM W24 BEAM

1'

- 2

11" 1' - 0" 2' - 3" 2' - 3" 1'

- 7

1'

- 9

3/ 4"

2'

- 6

1 1 /2"

1 1 /2"

1 1 /2"

1 1 /2"

1 1 /2"

1 1 /2"

1 1 /2"1 1

/2"

3/4" DIA. x6" EXP. ANCHOR

(TYP.)

1/2" PLATE

1 1 /2"

3"

O .C

MA

X.

1 1

/2"

9" 9"

9"

5 1/2" 8" 8" 5 1/2"5 1/2" 8" 8" 5 1/2"1 1/2" 8" 1 1/2" 1 1/2" 9" 1 1/2"

1'

- 4

7 1/2" 9" 7 1/2"

7 1/2" 9" 7 1/2"

BASE PLATE 1"x11-1/2"x11-1/2"

W/ (4)-3/4" DIA. ANCHOR BOLTS

1-1/2" MINIMUM GROUT BED

FOR LEVELING NUTS

11 1/2"

1 1/2"

8 1/2"

1 1/2"

HSS6x6 COLUMNS

BASE PLATE 1"x10-1/2"x10-1/2"

W/ (4)-3/4"…