Roofing IDIQ Bid Schedule for FBO - Roofing IDIQ.xlsx

XLSX spreadsheet 44 KB Posted

Attached to
Roofing IDIQ - Hurlburt Field, FL
Solicitation number
FA4417-10-R-0012
Issued by

About this file

FA4417-10-R-0012 Roofing IDIQ Bid Schedule ( Excel version). For your convenience attached is an excel version of the Roofing IDIQ Bid Schedule.

View the file

Other files

File Type Posted
Roof IDIQ Questions and Answers Part 5 final.pdf PDF
Roof IDIQ Questions and Answers Part 4 —
ROOF IDIQ Updated Bid Schedule 30 Jun 2010.xlsx XLSX spreadsheet
07550 Modified Bituminous Membrane Roofing Attch 3.pdf PDF
07600 sheet metal flashing Attch 4.pdf PDF
07220 Roof and Deck Insulation Attch 1.pdf PDF
Amend 02 and Questions and Answers Continued.pdf PDF
07410 preformed roofing 0610 Attch 2.pdf PDF
Roofing IDIQ Questions and Answers Continued.pdf PDF
FA4417-10-R-0012 Amend 01.pdf PDF
S-3.zip ZIP file
E8.zip ZIP file
pre-proposal meeting minutes.pdf PDF
Roofing Question and Answers from Site Visit.docx DOCX document
Roofing IDIQ Pre-bid site visit sign in sheet.pdf PDF
Attch 3 Roof IDIQ Specs 2010.pdf PDF
Attch 5 10-R-0012 WD FL080218.docx DOCX document
Attch 4 10-R-0012 WD FL080128.docx DOCX document
Attch 6 Roof IDIQ Past Performance Questionnaire.docx DOCX document
Attch 9 Seed Project Velocity Subs SOW.pdf PDF
Attch 2 IDIQ Statement of Work.pdf PDF
Roof IDIQ Solicitation FA4417-10-R-0012.pdf PDF
Attch 7 10-R-0012 Financial Questionnaire.docx DOCX document
Attch 8 Technical Evaluation Project.pdf PDF
FA4417-10-R-0012 Bid Schedule updated.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base

Base YearDESCRIPTION - SUPPLIES OR SERVICES AND PRICES/COSTS
LINEUNIT PRICE SCHEDULEUnitEST.Unit PriceTOTAL
ITEMIDIQ REPAIR AND REPLACE ROOFSQTY.
DIV 2 - SELECTIVE DEMOLITION
0001REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BFBF100$ - 0
0002REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BFBF100$ - 0
0003REMOVE AND REPLACE WOOD DECKINGBF10$ - 0
0004REMOVE AND REPLACE PLYWOOD ROOF SHEATHING, 3/4"SF200$ - 0
0005REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, 0-20 BFBF50$ - 0
0006REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, >20 BFBF50$ - 0
0007REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8")BF10$ - 0
DIV 2 - TEAR OFFS
0008DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC (DOES NOT INCLUDE INSULATION)SQ400$ - 0
0009DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3"SQ400$ - 0
0010REMOVE AND DISPOSE OF EXISTING SHINGLE ROOF SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGESSQ100$ - 0
0011REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGESSQ100$ - 0
0012DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEMSQ500$ - 0
DIV 5 - STEEL ROOF DECK
0013REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECKSQ50$ - 0
DIV 7 - INSULATION
0014POLYISOCYANURATE BOARD INSULATION - 1" THICK, R7.14SQ100$ - 0
0015POLYISOCYANURATE BOARD INSULATION - 2" THICK, R14.29SQ100$ - 0
0016POLYISOCYANURATE BOARD INSULATION - 3" THICK, R21.74SQ300$ - 0
0017PERLITE BOARD INSULATION, 3/4" THICK, R2.08, <=100 SQSQ200$ - 0
0018PERLITE BOARD INSULATION, 3/4" THICK, R2.08, >100 SQSQ200$ - 0
0019BATT ROOF INSULATION, R-19SF400$ - 0
0020FIBER CANTSLF250$ - 0
0021WOOD CANTSLF50$ - 0
0022TAPERED FILL INSULATION BOARDBF2,000$ - 0
0023TAPERED 1/4" PER FOOT FOR DRAINAGEBF3,000$ - 0
DIV 7 - SHINGLE ROOFING SYSTEMS
0024FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENTSQ40$ - 0
0025FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL FIBERGLASS SHINGLE SYSTEM INCLUDING UNDERLAYMENTSQ60$ - 0
0026REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRSSQ50$ - 0
0027ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER)SQ30$ - 0
0028FELT, GLASS FIBER, 15 POUND ORGANICSQ10$ - 0
0029FELT, GLASS FIBER, 30 POUND ORGANICSQ30$ - 0
DIV 7 - BITUMINOUS ROOFING (BURS)
00304-PLY BURS USING ASPHALTSQ50$ - 0
00314-PLY BURS USING COAL TARSQ50$ - 0
00324-PLY BURS WITH SBS MODIFIED CAP SHEETSQ100$ - 0
0033REMOVE AND REPLACE PITCH PANEA10$ - 0
DIV 7 - PARTIAL BURS REPAIRS
0034REPAIR BLISTERSSF100$ - 0
0035REPAIR SPLITSSF50$ - 0
0036REPAIR RIDGESSF50$ - 0
0037APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREASSF200$ - 0
DIV 7 - PREPARED ROLL ROOFING
0038FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS PREPARED ROLL ROOFING INCLUDING UNDERLAYMENTSQ100$ - 0
0039CUT-OUT AND PATCH ROLL ROOFINGSQ10$ - 0
DIV 7 - POLYVINYL-CHLORIDE ROOFING (PVC)
0040FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 48 MILSSQ1$ - 0
0041FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 72 MILSSQ1$ - 0
00042FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 60 MILSSQ1$ - 0
0043FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 72 MILSSQ1$ - 0
0044PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUTLF10$ - 0
0045PVC LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUTLF10$ - 0
0046PVC VENT BOOTSEA1$ - 0
0047PVC UNIVERSAL CORNERSEA1$ - 0
0048PATCH AND REPAIR PVC SYSTEMSF10$ - 0
DIV 7 - THERMOPLASTIC POLYOLEFIN ROOFING (TPO)
0049FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 45 MILSSQ1$ - 0
0050FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 60 MILSSQ1$ - 0
0051FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 45 MILSSQ1$ - 0
0052FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 60 MILSSQ1$ - 0
0053TPO LAMINATED METAL FLASHING UP TO 18" STRETCH OUTLF10$ - 0
0054TPO LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUTLF10$ - 0
0055TPO VENT BOOTSEA1$ - 0
0056TPO UNIVERSAL CORNERSEA1$ - 0
0057PATCH AND REPAIR TPO SYSTEMSF10$ - 0
DIV 7 - FLUID APPLIED ROOF COATING SYSTEM, METAL ROOFS
0058FLUID APPLIED COATING SYSTEM FOR METAL ROOFSSQ1$ - 0
DIV 7 - TRAFFIC BEARING ROOF DECK SURFACING
0059TRAFFIC BEARING ROOF DECK SURFACING SYSTEMSQ20$ - 0
DIV 7 - SHEET METAL WORK, GENERAL
FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION)
0060GALVANIZED METAL, 4"-5"LF150$ - 0
0061GALVANIZED METAL, 6"-7"LF150$ - 0
0062ALUMINUM, 4"-5"LF10$ - 0
0063ALUMINUM, 6"-7"LF10$ - 0
0064COPPER, 4"-5"LF10$ - 0
0065COPPER, 6"-7"LF10$ - 0
00662-PIECE GALVANIZED METAL, 7"-10"LF20$ - 0
00672-PIECE GALVANIZED METAL, 10"-12"LF20$ - 0
00682-PIECE ALUMINUM, 7"-10"LF10$ - 0
00692-PIECE ALUMINUM, 10"-12"LF10$ - 0
00702-PIECE COPPER, 7"-10"LF10$ - 0
00712-PIECE COPPER, 10"-12"LF10$ - 0
FURNISH AND INSTALL:
0072GALVANIZED METAL DRIP EDGELF100$ - 0
0073GALVANIZED METAL COUNTERFLASHINGSF200$ - 0
0074GALVANIZED METAL VALLEY FLASHINGSF100$ - 0
0075GALVANIZED METAL STEP FLASHINGSF20$ - 0
0076GALVANIZED METAL BASE FLASHINGSF20$ - 0
0077GALVANIZED METAL FLASHING, FLAT SHEETSF200$ - 0
0078GALVANIZED METAL CAP FLASHINGSF100$ - 0
0079ALUMINUM DRIP EDGELF10$ - 0
0080ALUMINUM COUNTERFLASHINGSF10$ - 0
0081ALUMINUM VALLEY FLASHINGSF10$ - 0
0082ALUMINUM STEP FLASHINGSF10$ - 0
0083ALUMINUM BASE FLASHINGSF10$ - 0
0084ALUMINUM FLASHING, FLAT SHEETSF10$ - 0
0085ALUMINUM CAP FLASHINGSF10$ - 0
0086METAL RIDGE VENT/CAPLF1000$ - 0
REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT
0087ELASTOMERIC TYPE (NEOPRENE BELLOWS)LF50$ - 0
0088ALUMINUM CAPPED CURBLF10$ - 0
0089GALVANIZED CAPPED CURBLF50$ - 0
MISCELLANEOUS ITEMS
0090REMOVE AND REPLACE VENTILATOR, ROOFTOPEA1$ - 0
0091REMOVE AND REPLACE VENTILATOR, RIDGELF60$ - 0
0092REMOVE AND REPLACE VENTILATOR, GABLEEA1$ - 0
0093REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHEDEA1$ - 0
0094REMOVE AND REPLACE ROOF SCUTTLEEA1$ - 0
DIV 7 - GUTTERS AND DOWNSPOUTS
0095REMOVE EXISTING GUTTER AND DOWNSPOUTSLF300$ - 0
FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC.
009624 GA. GALVANIZED/PRIMED, 4" X 5"LF50$ - 0
009724 GA. GALVANIZED/PRIMED, 5" X 7"LF200$ - 0
0098ALUMINUM, 4" X 5"LF10$ - 0
0099ALUMINUM, 5" X 7"LF10$ - 0
010016 OZ. COPPER, 4" X 5"LF10$ - 0
010116 OZ. COPPER, 5" X 7"LF10$ - 0
FURNISH AND INSTALL NEW DOWNSPOUTS INCLUDES BRACKETS, ETC.
010224 GA. GALVANIZED/PRIMED, 3" X 4"LF100$ - 0
0103ALUMINUM, 3" X 4"LF10$ - 0
010416 OZ. COPPER, 3" X 4"LF10$ - 0
0105FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKSEA5$ - 0
DIV 7 - MANUFACTURED ROOF FRAMING SYSTEM
0106RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, <=100 SQSQ50$ - 0
0107RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, >100 SQSQ110$ - 0
DIV 7 - STANDING SEAM METAL ROOFING
0108NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL <=100 SQSQ200$ - 0
0109NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQSQ200$ - 0
0110FASCIA PANEL SYSTEMSF1,000$ - 0
0111NON-PERFORATED SOFFIT PANELSF700$ - 0
0112PERFORATED SOFFIT PANELSF300$ - 0
DIV 7 - CAULKING AND SEALANTS
0113REMOVE EXISTING CAULKING / CLEAN JOINTLF150$ - 0
0114SILICONE CAULKING / SEALANTLF150$ - 0
0115CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1 OR APPROVED EQUAL)LF50$ - 0
DIV 9 - PAINTING
0116Reserved
0117PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATSSF500$ - 0
DIV 15 - ROOF DRAINS
0118REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINEREA10$ - 0
0119REMOVE AND REPLACE EXISTING ROOF DRAIN INCLUDES NEW CAST IRON DRAIN AND DOME STRAINER.EA10$ - 0
DIV 16 - LIGHTING PROTECTION
0120REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERSLS3$ - 0
0121REMOVE AND REINSTALL EXISTING CONDUCTORLF300$ - 0
0122REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPSEA100$ - 0
REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTING PROTECTION SYSTEM
0123AIR TERMINALS, INCLUDES COPPER BASEEA10$ - 0
0124CONDUCTORSLF100$ - 0
0125FASTENERS, INCLUDES LOOPS AND CLIPSEA1$ - 0
0126CONNECTORSEA1$ - 0
0127GROUNDING RODSEA1$ - 0
0128SURGE PROTECTIONEA1$ - 0
0129UL SITE INSPECTIONEA1$ - 0
MISCELLANEOUS ROOFING ITEMS
0130EXTEND PLUMBING VENTSLF10$ - 0
0131FLEXIBLE VENT PIPE FLASHING (METAL ROOFS)EA20$ - 0
0132REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR), BUR'sEA30$ - 0
0133REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH NEW COLLAR TYPE FLASHINGEA10$ - 0
0134REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECKSF50$ - 0
0135FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKSSQ10$ - 0
0136FURNISH AND INSTALL ROSIN PAPER OVER WOOD ROOF DECKSSQ1$ - 0
0137DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP)EA1$ - 0
0138REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC.LF50$ - 0
0139ROLL COIL RIDGE VENTLF300$ - 0
014060MIL WATERPROOF UNDERLAYMENTLF100$ - 0
0141SPUD EXISTING ROOF TO INSULATIONSF100$ - 0
0142TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREAEA5$ - 0
ENGINEERING / SUB-CONTRACTORS
0143ENGINEERING RATE STRUCTURALHR20$ - 0
0144MECHANICAL SUBCONTRACTOR (SHEET METAL WORKER)HR20$ - 0
0145ELECTRICAL SUBCONTRACTOR (ELECTRICIAN)HR20$ - 0
0146LABOR RATE - MISCELLANEOUS WORK (SHEET METAL WORKER)MH40$ - 0
SPECIAL CONDITIONS AND CIRCUMSTANCES
0147HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOBEA2$ - 0
MODIFIERS
0148COEFFICIENT % TO BE MULTIPLIED TO TOTAL FOR URGENT DELIVERY ORDER (UDO) - TEMPORARY DRY-IN WORK ONLY35%

TOTAL $ - 0

option 1

OPTION 1DESCRIPTION - SUPPLIES OR SERVICES AND PRICES/COSTS
LINEUNIT PRICE SCHEDULEUnitEST.unit priceTOTAL
ITEMIDIQ REPAIR AND REPLACE ROOFSQTY.
DIV 2 - SELECTIVE DEMOLITION
1001REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BFBF100$ - 0
1002REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BFBF100$ - 0
1003REMOVE AND REPLACE WOOD DECKINGBF10$ - 0
1004REMOVE AND REPLACE PLYWOOD ROOF SHEATHING, 3/4"SF200$ - 0
1005REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, 0-20 BFBF50$ - 0
1006REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, >20 BFBF50$ - 0
1007REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8")BF10$ - 0
DIV 2 - TEAR OFFS
1008DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC (DOES NOT INCLUDE INSULATION)SQ400$ - 0
1009DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3"SQ400$ - 0
1010REMOVE AND DISPOSE OF EXISTING SHINGLE ROOF SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGESSQ100$ - 0
1011REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGESSQ100$ - 0
1012DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEMSQ500$ - 0
DIV 5 - STEEL ROOF DECK
1013REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECKSQ50$ - 0
DIV 7 - INSULATION
1014POLYISOCYANURATE BOARD INSULATION - 1" THICK, R7.14SQ100$ - 0
1015POLYISOCYANURATE BOARD INSULATION - 2" THICK, R14.29SQ100$ - 0
1016POLYISOCYANURATE BOARD INSULATION - 3" THICK, R21.74SQ300$ - 0
1017PERLITE BOARD INSULATION, 3/4" THICK, R2.08, <=100 SQSQ200$ - 0
1018PERLITE BOARD INSULATION, 3/4" THICK, R2.08, >100 SQSQ200$ - 0
1019BATT ROOF INSULATION, R-19SF400$ - 0
1020FIBER CANTSLF250$ - 0
1021WOOD CANTSLF50$ - 0
1022TAPERED FILL INSULATION BOARDBF2,000$ - 0
1023TAPERED 1/4" PER FOOT FOR DRAINAGEBF3,000$ - 0
DIV 7 - SHINGLE ROOFING SYSTEMS
1024FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENTSQ40$ - 0
1025FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL FIBERGLASS SHINGLE SYSTEM INCLUDING UNDERLAYMENTSQ60$ - 0
1026REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRSSQ50$ - 0
1027ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER)SQ30$ - 0
1028FELT, GLASS FIBER, 15 POUND ORGANICSQ10$ - 0
1029FELT, GLASS FIBER, 30 POUND ORGANICSQ30$ - 0
DIV 7 - BITUMINOUS ROOFING (BURS)
10304-PLY BURS USING ASPHALTSQ50$ - 0
10314-PLY BURS USING COAL TARSQ50$ - 0
10324-PLY BURS WITH SBS MODIFIED CAP SHEETSQ100$ - 0
1033REMOVE AND REPLACE PITCH PANEA10$ - 0
DIV 7 - PARTIAL BURS REPAIRS
1034REPAIR BLISTERSSF100$ - 0
1035REPAIR SPLITSSF50$ - 0
1036REPAIR RIDGESSF50$ - 0
1037APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREASSF200$ - 0
DIV 7 - PREPARED ROLL ROOFING
1038FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS PREPARED ROLL ROOFING INCLUDING UNDERLAYMENTSQ100$ - 0
1039CUT-OUT AND PATCH ROLL ROOFINGSQ10$ - 0
DIV 7 - POLYVINYL-CHLORIDE ROOFING (PVC)
1040FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 48 MILSSQ1$ - 0
1041FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 72 MILSSQ1$ - 0
1042FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 60 MILSSQ1$ - 0
1043FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 72 MILSSQ1$ - 0
1044PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUTLF10$ - 0
1045PVC LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUTLF10$ - 0
1046PVC VENT BOOTSEA1$ - 0
1047PVC UNIVERSAL CORNERSEA1$ - 0
1048PATCH AND REPAIR PVC SYSTEMSF10$ - 0
DIV 7 - THERMOPLASTIC POLYOLEFIN ROOFING (TPO)
1049FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 45 MILSSQ1$ - 0
1050FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 60 MILSSQ1$ - 0
1051FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 45 MILSSQ1$ - 0
1052FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 60 MILSSQ1$ - 0
1053TPO LAMINATED METAL FLASHING UP TO 18" STRETCH OUTLF10$ - 0
1054TPO LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUTLF10$ - 0
1055TPO VENT BOOTSEA1$ - 0
1056TPO UNIVERSAL CORNERSEA1$ - 0
1057PATCH AND REPAIR TPO SYSTEMSF10$ - 0
DIV 7 - FLUID APPLIED ROOF COATING SYSTEM, METAL ROOFS
1058FLUID APPLIED COATING SYSTEM FOR METAL ROOFSSQ1$ - 0
DIV 7 - TRAFFIC BEARING ROOF DECK SURFACING
1059TRAFFIC BEARING ROOF DECK SURFACING SYSTEMSQ20$ - 0
DIV 7 - SHEET METAL WORK, GENERAL
FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION)
1060GALVANIZED METAL, 4"-5"LF150$ - 0
1061GALVANIZED METAL, 6"-7"LF150$ - 0
1062ALUMINUM, 4"-5"LF10$ - 0
1063ALUMINUM, 6"-7"LF10$ - 0
1064COPPER, 4"-5"LF10$ - 0
1065COPPER, 6"-7"LF10$ - 0
10662-PIECE GALVANIZED METAL, 7"-10"LF20$ - 0
10672-PIECE GALVANIZED METAL, 10"-12"LF20$ - 0
10682-PIECE ALUMINUM, 7"-10"LF10$ - 0
10692-PIECE ALUMINUM, 10"-12"LF10$ - 0
10702-PIECE COPPER, 7"-10"LF10$ - 0
10712-PIECE COPPER, 10"-12"LF10$ - 0
FURNISH AND INSTALL:
1072GALVANIZED METAL DRIP EDGELF100$ - 0
1073GALVANIZED METAL COUNTERFLASHINGSF200$ - 0
1074GALVANIZED METAL VALLEY FLASHINGSF100$ - 0
1075GALVANIZED METAL STEP FLASHINGSF20$ - 0
1076GALVANIZED METAL BASE FLASHINGSF20$ - 0
1077GALVANIZED METAL FLASHING, FLAT SHEETSF200$ - 0
1078GALVANIZED METAL CAP FLASHINGSF100$ - 0
1079ALUMINUM DRIP EDGELF10$ - 0
1080ALUMINUM COUNTERFLASHINGSF10$ - 0
1081ALUMINUM VALLEY FLASHINGSF10$ - 0
1082ALUMINUM STEP FLASHINGSF10$ - 0
1083ALUMINUM BASE FLASHINGSF10$ - 0
1084ALUMINUM FLASHING, FLAT SHEETSF10$ - 0
1085ALUMINUM CAP FLASHINGSF10$ - 0
1086METAL RIDGE VENT/CAPLF1000$ - 0
REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT
1087ELASTOMERIC TYPE (NEOPRENE BELLOWS)LF50$ - 0
1088ALUMINUM CAPPED CURBLF10$ - 0
1089GALVANIZED CAPPED CURBLF50$ - 0
MISCELLANEOUS ITEMS
1090REMOVE AND REPLACE VENTILATOR, ROOFTOPEA1$ - 0
1091REMOVE AND REPLACE VENTILATOR, RIDGELF60$ - 0
1092REMOVE AND REPLACE VENTILATOR, GABLEEA1$ - 0
1093REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHEDEA1$ - 0
1094REMOVE AND REPLACE ROOF SCUTTLEEA1$ - 0
DIV 7 - GUTTERS AND DOWNSPOUTS
1095REMOVE EXISTING GUTTER AND DOWNSPOUTSLF300$ - 0
FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC.
109624 GA. GALVANIZED/PRIMED, 4" X 5"LF50$ - 0
109724 GA. GALVANIZED/PRIMED, 5" X 7"LF200$ - 0
1098ALUMINUM, 4" X 5"LF10$ - 0
1099ALUMINUM, 5" X 7"LF10$ - 0
110016 OZ. COPPER, 4" X 5"LF10$ - 0
110116 OZ. COPPER, 5" X 7"LF10$ - 0
FURNISH AND INSTALL NEW DOWNSPOUTS INCLUDES BRACKETS, ETC.
110224 GA. GALVANIZED/PRIMED, 3" X 4"LF100$ - 0
1103ALUMINUM, 3" X 4"LF10$ - 0
110416 OZ. COPPER, 3" X 4"LF10$ - 0
1105FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKSEA5$ - 0
DIV 7 - MANUFACTURED ROOF FRAMING SYSTEM
1106RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, <=100 SQSQ50$ - 0
1107RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, >100 SQSQ110$ - 0
DIV 7 - STANDING SEAM METAL ROOFING
1108NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL <=100 SQSQ200$ - 0
1109NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQSQ200$ - 0
1110FASCIA PANEL SYSTEMSF1,000$ - 0
1111NON-PERFORATED SOFFIT PANELSF700$ - 0
1112PERFORATED SOFFIT PANELSF300$ - 0
DIV 7 - CAULKING AND SEALANTS
1113REMOVE EXISTING CAULKING / CLEAN JOINTLF150$ - 0
1114SILICONE CAULKING / SEALANTLF150$ - 0
1115CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1 OR APPROVED EQUAL)LF50$ - 0
DIV 9 - PAINTING
1116Reserved
1117PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATSSF500$ - 0
DIV 15 - ROOF DRAINS
1118REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINEREA10$ - 0
1119REMOVE AND REPLACE EXISTING ROOF DRAIN INCLUDES NEW CAST IRON DRAIN AND DOME STRAINER.EA10$ - 0
DIV 16 - LIGHTING PROTECTION
1120REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERSLS3$ - 0
1121REMOVE AND REINSTALL EXISTING CONDUCTORLF300$ - 0
1122REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPSEA100$ - 0
REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTING PROTECTION SYSTEM
1123AIR TERMINALS, INCLUDES COPPER BASEEA10$ - 0
1124CONDUCTORSLF100$ - 0
1125FASTENERS, INCLUDES LOOPS AND CLIPSEA1$ - 0
1126CONNECTORSEA1$ - 0
1127GROUNDING RODSEA1$ - 0
1128SURGE PROTECTIONEA1$ - 0
1129UL SITE INSPECTIONEA1$ - 0
MISCELLANEOUS ROOFING ITEMS
1130EXTEND PLUMBING VENTSLF10$ - 0
1131FLEXIBLE VENT PIPE FLASHING (METAL ROOFS)EA20$ - 0
1132REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR), BUR'sEA30$ - 0
1133REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH NEW COLLAR TYPE FLASHINGEA10$ - 0
1134REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECKSF50$ - 0
1135FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKSSQ10$ - 0
1136FURNISH AND INSTALL ROSIN PAPER OVER WOOD ROOF DECKSSQ1$ - 0
1137DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP)EA1$ - 0
1138REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC.LF50$ - 0
1139ROLL COIL RIDGE VENTLF300$ - 0
114060MIL WATERPROOF UNDERLAYMENTLF100$ - 0
1141SPUD EXISTING ROOF TO INSULATIONSF100$ - 0
1142TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREAEA5$ - 0
ENGINEERING / SUB-CONTRACTORS
1143ENGINEERING RATE STRUCTURALHR20$ - 0
1144MECHANICAL SUBCONTRACTOR (SHEET METAL WORKER)HR20$ - 0
1145ELECTRICAL SUBCONTRACTOR (ELECTRICIAN)HR20$ - 0
1146LABOR RATE - MISCELLANEOUS WORK (SHEET METAL WORKER)MH40$ - 0
SPECIAL CONDITIONS AND CIRCUMSTANCES
1147HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOBEA2$ - 0
MODIFIERS
1148COEFFICIENT % TO BE MULTIPLIED TO TOTAL FOR URGENT DELIVERY ORDER (UDO) - TEMPORARY DRY-IN WORK ONLY35%

TOTAL $ - 0

option 2

OPTION 2DESCRIPTION - SUPPLIES OR SERVICES AND PRICES/COSTS
LINEUNIT PRICE SCHEDULEUnitEST.unit priceTOTAL
ITEMIDIQ REPAIR AND REPLACE ROOFSQTY.
DIV 2 - SELECTIVE DEMOLITION
2001REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BFBF100$ - 0
2002REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BFBF100$ - 0
2003REMOVE AND REPLACE WOOD DECKINGBF10$ - 0
2004REMOVE AND REPLACE PLYWOOD ROOF SHEATHING, 3/4"SF200$ - 0
2005REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, 0-20 BFBF50$ - 0
2006REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, >20 BFBF50$ - 0
2007REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8")BF10$ - 0
DIV 2 - TEAR OFFS
2008DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC (DOES NOT INCLUDE INSULATION)SQ400$ - 0
2009DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3"SQ400$ - 0
2010REMOVE AND DISPOSE OF EXISTING SHINGLE ROOF SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGESSQ100$ - 0
2011REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGESSQ100$ - 0
2012DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEMSQ500$ - 0
DIV 5 - STEEL ROOF DECK
2013REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECKSQ50$ - 0
DIV 7 - INSULATION
2014POLYISOCYANURATE BOARD INSULATION - 1" THICK, R7.14SQ100$ - 0
2015POLYISOCYANURATE BOARD INSULATION - 2" THICK, R14.29SQ100$ - 0
2016POLYISOCYANURATE BOARD INSULATION - 3" THICK, R21.74SQ300$ - 0
2017PERLITE BOARD INSULATION, 3/4" THICK, R2.08, <=100 SQSQ200$ - 0
2018PERLITE BOARD INSULATION, 3/4" THICK, R2.08, >100 SQSQ200$ - 0
2019BATT ROOF INSULATION, R-19SF400$ - 0
2020FIBER CANTSLF250$ - 0
2021WOOD CANTSLF50$ - 0
2022TAPERED FILL INSULATION BOARDBF2,000$ - 0
2023TAPERED 1/4" PER FOOT FOR DRAINAGEBF3,000$ - 0
DIV 7 - SHINGLE ROOFING SYSTEMS
2024FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENTSQ40$ - 0
2025FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL FIBERGLASS SHINGLE SYSTEM INCLUDING UNDERLAYMENTSQ60$ - 0
2026REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRSSQ50$ - 0
2027ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER)SQ30$ - 0
2028FELT, GLASS FIBER, 15 POUND ORGANICSQ10$ - 0
2029FELT, GLASS FIBER, 30 POUND ORGANICSQ30$ - 0
DIV 7 - BITUMINOUS ROOFING (BURS)
20304-PLY BURS USING ASPHALTSQ50$ - 0
20314-PLY BURS USING COAL TARSQ50$ - 0
20324-PLY BURS WITH SBS MODIFIED CAP SHEETSQ100$ - 0
2033REMOVE AND REPLACE PITCH PANEA10$ - 0
DIV 7 - PARTIAL BURS REPAIRS
2034REPAIR BLISTERSSF100$ - 0
2035REPAIR SPLITSSF50$ - 0
2036REPAIR RIDGESSF50$ - 0
2037APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREASSF200$ - 0
DIV 7 - PREPARED ROLL ROOFING
2038FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS PREPARED ROLL ROOFING INCLUDING UNDERLAYMENTSQ100$ - 0
2039CUT-OUT AND PATCH ROLL ROOFINGSQ10$ - 0
DIV 7 - POLYVINYL-CHLORIDE ROOFING (PVC)
2040FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 48 MILSSQ1$ - 0
2041FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 72 MILSSQ1$ - 0
2042FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 60 MILSSQ1$ - 0
2043FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 72 MILSSQ1$ - 0
2044PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUTLF10$ - 0
2045PVC LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUTLF10$ - 0
2046PVC VENT BOOTSEA1$ - 0
2047PVC UNIVERSAL CORNERSEA1$ - 0
2048PATCH AND REPAIR PVC SYSTEMSF10$ - 0
DIV 7 - THERMOPLASTIC POLYOLEFIN ROOFING (TPO)
2049FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 45 MILSSQ1$ - 0
2050FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 60 MILSSQ1$ - 0
2051FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 45 MILSSQ1$ - 0
2052FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 60 MILSSQ1$ - 0
2053TPO LAMINATED METAL FLASHING UP TO 18" STRETCH OUTLF10$ - 0
2054TPO LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUTLF10$ - 0
2055TPO VENT BOOTSEA1$ - 0
2056TPO UNIVERSAL CORNERSEA1$ - 0
2057PATCH AND REPAIR TPO SYSTEMSF10$ - 0
DIV 7 - FLUID APPLIED ROOF COATING SYSTEM, METAL ROOFS
2058FLUID APPLIED COATING SYSTEM FOR METAL ROOFSSQ1$ - 0
DIV 7 - TRAFFIC BEARING ROOF DECK SURFACING
2059TRAFFIC BEARING ROOF DECK SURFACING SYSTEMSQ20$ - 0
DIV 7 - SHEET METAL WORK, GENERAL
FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION)
2060GALVANIZED METAL, 4"-5"LF150$ - 0
2061GALVANIZED METAL, 6"-7"LF150$ - 0
2062ALUMINUM, 4"-5"LF10$ - 0
2063ALUMINUM, 6"-7"LF10$ - 0
2064COPPER, 4"-5"LF10$ - 0
2065COPPER, 6"-7"LF10$ - 0
20662-PIECE GALVANIZED METAL, 7"-10"LF20$ - 0
20672-PIECE GALVANIZED METAL, 10"-12"LF20$ - 0
20682-PIECE ALUMINUM, 7"-10"LF10$ - 0
20692-PIECE ALUMINUM, 10"-12"LF10$ - 0
20702-PIECE COPPER, 7"-10"LF10$ - 0
20712-PIECE COPPER, 10"-12"LF10$ - 0
FURNISH AND INSTALL:
2072GALVANIZED METAL DRIP EDGELF100$ - 0
2073GALVANIZED METAL COUNTERFLASHINGSF200$ - 0
2074GALVANIZED METAL VALLEY FLASHINGSF100$ - 0
2075GALVANIZED METAL STEP FLASHINGSF20$ - 0
2076GALVANIZED METAL BASE FLASHINGSF20$ - 0
2077GALVANIZED METAL FLASHING, FLAT SHEETSF200$ - 0
2078GALVANIZED METAL CAP FLASHINGSF100$ - 0
2079ALUMINUM DRIP EDGELF10$ - 0
2080ALUMINUM COUNTERFLASHINGSF10$ - 0
2081ALUMINUM VALLEY FLASHINGSF10$ - 0
2082ALUMINUM STEP FLASHINGSF10$ - 0
2083ALUMINUM BASE FLASHINGSF10$ - 0
2084ALUMINUM FLASHING, FLAT SHEETSF10$ - 0
2085ALUMINUM CAP FLASHINGSF10$ - 0
2086METAL RIDGE VENT/CAPLF1000$ - 0
REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT
2087ELASTOMERIC TYPE (NEOPRENE BELLOWS)LF50$ - 0
2088ALUMINUM CAPPED CURBLF10$ - 0
2089GALVANIZED CAPPED CURBLF50$ - 0
MISCELLANEOUS ITEMS
2090REMOVE AND REPLACE VENTILATOR, ROOFTOPEA1$ - 0
2091REMOVE AND REPLACE VENTILATOR, RIDGELF60$ - 0
2092REMOVE AND REPLACE VENTILATOR, GABLEEA1$ - 0
2093REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHEDEA1$ - 0
2094REMOVE AND REPLACE ROOF SCUTTLEEA1$ - 0
DIV 7 - GUTTERS AND DOWNSPOUTS
2095REMOVE EXISTING GUTTER AND DOWNSPOUTSLF300$ - 0
FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC.
209624 GA. GALVANIZED/PRIMED, 4" X 5"LF50$ - 0
209724 GA. GALVANIZED/PRIMED, 5" X 7"LF200$ - 0
2098ALUMINUM, 4" X 5"LF10$ - 0
2099ALUMINUM, 5" X 7"LF10$ - 0
210016 OZ. COPPER, 4" X 5"LF10$ - 0
210116 OZ. COPPER, 5" X 7"LF10$ - 0
FURNISH AND INSTALL NEW DOWNSPOUTS INCLUDES BRACKETS, ETC.
210224 GA. GALVANIZED/PRIMED, 3" X 4"LF100$ - 0
2103ALUMINUM, 3" X 4"LF10$ - 0
210416 OZ. COPPER, 3" X 4"LF10$ - 0
2105FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKSEA5$ - 0
DIV 7 - MANUFACTURED ROOF FRAMING SYSTEM
2106RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, <=100 SQSQ50$ - 0
2107RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, >100 SQSQ110$ - 0
DIV 7 - STANDING SEAM METAL ROOFING
2108NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL <=100 SQSQ200$ - 0
2109NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQSQ200$ - 0
2110FASCIA PANEL SYSTEMSF1,000$ - 0
2111NON-PERFORATED SOFFIT PANELSF700$ - 0
2112PERFORATED SOFFIT PANELSF300$ - 0
DIV 7 - CAULKING AND SEALANTS
2113REMOVE EXISTING CAULKING / CLEAN JOINTLF150$ - 0
2114SILICONE CAULKING / SEALANTLF150$ - 0
2115CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1 OR APPROVED EQUAL)LF50$ - 0
DIV 9 - PAINTING
2116Reserved
2117PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATSSF500$ - 0
DIV 15 - ROOF DRAINS
2118REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINEREA10$ - 0
2119REMOVE AND REPLACE EXISTING ROOF DRAIN INCLUDES NEW CAST IRON DRAIN AND DOME STRAINER.EA10$ - 0
DIV 16 - LIGHTING PROTECTION
2120REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERSLS3$ - 0
2121REMOVE AND REINSTALL EXISTING CONDUCTORLF300$ - 0
2122REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPSEA100$ - 0
REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTING PROTECTION SYSTEM
2123AIR TERMINALS, INCLUDES COPPER BASEEA10$ - 0
2124CONDUCTORSLF100$ - 0
2125FASTENERS, INCLUDES LOOPS AND CLIPSEA1$ - 0
2126CONNECTORSEA1$ - 0
2127GROUNDING RODSEA1$ - 0
2128SURGE PROTECTIONEA1$ - 0
2129UL SITE INSPECTIONEA1$ - 0
MISCELLANEOUS ROOFING ITEMS
2130EXTEND PLUMBING VENTSLF10$ - 0
2131FLEXIBLE VENT PIPE FLASHING (METAL ROOFS)EA20$ - 0
2132REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR), BUR'sEA30$ - 0
2133REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH NEW COLLAR TYPE FLASHINGEA10$ - 0
2134REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECKSF50$ - 0
2135FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKSSQ10$ - 0
2136FURNISH AND INSTALL ROSIN PAPER OVER WOOD ROOF DECKSSQ1$ - 0
2137DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP)EA1$ - 0
2138REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC.LF50$ - 0
2139ROLL COIL RIDGE VENTLF300$ - 0
214060MIL WATERPROOF UNDERLAYMENTLF100$ - 0
2141SPUD EXISTING ROOF TO INSULATIONSF100$ - 0
2142TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREAEA5$ - 0
ENGINEERING / SUB-CONTRACTORS
2143ENGINEERING RATE STRUCTURALHR20$ - 0
2144MECHANICAL SUBCONTRACTOR (SHEET METAL WORKER)HR20$ - 0
2145ELECTRICAL SUBCONTRACTOR (ELECTRICIAN)HR20$ - 0
2146LABOR RATE - MISCELLANEOUS WORK (SHEET METAL WORKER)MH40$ - 0
SPECIAL CONDITIONS AND CIRCUMSTANCES
2147HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOBEA2$ - 0
MODIFIERS
2148COEFFICIENT % TO BE MULTIPLIED TO TOTAL FOR URGENT DELIVERY ORDER (UDO) - TEMPORARY DRY-IN WORK ONLY35%

TOTAL $ - 0

option 3

OPTION 3DESCRIPTION - SUPPLIES OR SERVICES AND PRICES/COSTS
LINEUNIT PRICE SCHEDULEUnitEST.unit priceTOTAL
ITEMIDIQ REPAIR AND REPLACE ROOFSQTY.
DIV 2 - SELECTIVE DEMOLITION
3001REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BFBF100$ - 0
3002REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BFBF100$ - 0
3003REMOVE AND REPLACE WOOD DECKINGBF10$ - 0
3004REMOVE AND REPLACE PLYWOOD ROOF SHEATHING, 3/4"SF200$ - 0
3005REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, 0-20 BFBF50$ - 0
3006REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, >20 BFBF50$ - 0
3007REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8")BF10$ - 0
DIV 2 - TEAR OFFS
3008DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC (DOES NOT INCLUDE INSULATION)SQ400$ - 0
3009DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3"SQ400$ - 0
3010REMOVE AND DISPOSE OF EXISTING SHINGLE ROOF SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGESSQ100$ - 0
3011REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGESSQ100$ - 0
3012DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEMSQ500$ - 0
DIV 5 - STEEL ROOF DECK
3013REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECKSQ50$ - 0
DIV 7 - INSULATION
3014POLYISOCYANURATE BOARD INSULATION - 1" THICK, R7.14SQ100$ - 0
3015POLYISOCYANURATE BOARD INSULATION - 2" THICK, R14.29SQ100$ - 0
3016POLYISOCYANURATE BOARD INSULATION - 3" THICK, R21.74SQ300$ - 0
3017PERLITE BOARD INSULATION, 3/4" THICK, R2.08, <=100 SQSQ200$ - 0
3018PERLITE BOARD INSULATION, 3/4" THICK, R2.08, >100 SQSQ200$ - 0
3019BATT ROOF INSULATION, R-19SF400$ - 0
3020FIBER CANTSLF250$ - 0
3021WOOD CANTSLF50$ - 0
3022TAPERED FILL INSULATION BOARDBF2,000$ - 0
3023TAPERED 1/4" PER FOOT FOR DRAINAGEBF3,000$ - 0
DIV 7 - SHINGLE ROOFING SYSTEMS
3024FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENTSQ40$ - 0
3025FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL FIBERGLASS SHINGLE SYSTEM INCLUDING UNDERLAYMENTSQ60$ - 0
3026REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRSSQ50$ - 0
3027ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER)SQ30$ - 0
3028FELT, GLASS FIBER, 15 POUND ORGANICSQ10$ - 0
3029FELT, GLASS FIBER, 30 POUND ORGANICSQ30$ - 0
DIV 7 - BITUMINOUS ROOFING (BURS)
30304-PLY BURS USING ASPHALTSQ50$ - 0
30314-PLY BURS USING COAL TARSQ50$ - 0
30324-PLY BURS WITH SBS MODIFIED CAP SHEETSQ100$ - 0
3033REMOVE AND REPLACE PITCH PANEA10$ - 0
DIV 7 - PARTIAL BURS REPAIRS
3034REPAIR BLISTERSSF100$ - 0
3035REPAIR SPLITSSF50$ - 0
3036REPAIR RIDGESSF50$ - 0
3037APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREASSF200$ - 0
DIV 7 - PREPARED ROLL ROOFING
3038FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS PREPARED ROLL ROOFING INCLUDING UNDERLAYMENTSQ100$ - 0
3039CUT-OUT AND PATCH ROLL ROOFINGSQ10$ - 0
DIV 7 - POLYVINYL-CHLORIDE ROOFING (PVC)
3040FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 48 MILSSQ1$ - 0
3041FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 72 MILSSQ1$ - 0
3042FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 60 MILSSQ1$ - 0
3043FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 72 MILSSQ1$ - 0
3044PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUTLF10$ - 0
3045PVC LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUTLF10$ - 0
3046PVC VENT BOOTSEA1$ - 0
3047PVC UNIVERSAL CORNERSEA1$ - 0
3048PATCH AND REPAIR PVC SYSTEMSF10$ - 0
DIV 7 - THERMOPLASTIC POLYOLEFIN ROOFING (TPO)
3049FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 45 MILSSQ1$ - 0
3050FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 60 MILSSQ1$ - 0
3051FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 45 MILSSQ1$ - 0
3052FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 60 MILSSQ1$ - 0
3053TPO LAMINATED METAL FLASHING UP TO 18" STRETCH OUTLF10$ - 0
3054TPO LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUTLF10$ - 0
3055TPO VENT BOOTSEA1$ - 0
3056TPO UNIVERSAL CORNERSEA1$ - 0
3057PATCH AND REPAIR TPO SYSTEMSF10$ - 0
DIV 7 - FLUID APPLIED ROOF COATING SYSTEM, METAL ROOFS
3058FLUID APPLIED COATING SYSTEM FOR METAL ROOFSSQ1$ - 0
DIV 7 - TRAFFIC BEARING ROOF DECK SURFACING
3059TRAFFIC BEARING ROOF DECK SURFACING SYSTEMSQ20$ - 0
DIV 7 - SHEET METAL WORK, GENERAL
FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION)
3060GALVANIZED METAL, 4"-5"LF150$ - 0
3061GALVANIZED METAL, 6"-7"LF150$ - 0
3062ALUMINUM, 4"-5"LF10$ - 0
3063ALUMINUM, 6"-7"LF10$ - 0
3064COPPER, 4"-5"LF10$ - 0
3065COPPER, 6"-7"LF10$ - 0
30662-PIECE GALVANIZED METAL, 7"-10"LF20$ - 0
30672-PIECE GALVANIZED METAL, 10"-12"LF20$ - 0
30682-PIECE ALUMINUM, 7"-10"LF10$ - 0
30692-PIECE ALUMINUM, 10"-12"LF10$ - 0
30702-PIECE COPPER, 7"-10"LF10$ - 0
30712-PIECE COPPER, 10"-12"LF10$ - 0
FURNISH AND INSTALL:
3072GALVANIZED METAL DRIP EDGELF100$ - 0
3073GALVANIZED METAL COUNTERFLASHINGSF200$ - 0
3074GALVANIZED METAL VALLEY FLASHINGSF100$ - 0
3075GALVANIZED METAL STEP FLASHINGSF20$ - 0
3076GALVANIZED METAL BASE FLASHINGSF20$ - 0
3077GALVANIZED METAL FLASHING, FLAT SHEETSF200$ - 0
3078GALVANIZED METAL CAP FLASHINGSF100$ - 0
3079ALUMINUM DRIP EDGELF10$ - 0
3080ALUMINUM COUNTERFLASHINGSF10$ - 0
3081ALUMINUM VALLEY FLASHINGSF10$ - 0
3082ALUMINUM STEP FLASHINGSF10$ - 0
3083ALUMINUM BASE FLASHINGSF10$ - 0
3084ALUMINUM FLASHING, FLAT SHEETSF10$ - 0
3085ALUMINUM CAP FLASHINGSF10$ - 0
3086METAL RIDGE VENT/CAPLF1000$ - 0
REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT
3087ELASTOMERIC TYPE (NEOPRENE BELLOWS)LF50$ - 0
3088ALUMINUM CAPPED CURBLF10$ - 0
3089GALVANIZED CAPPED CURBLF50$ - 0
MISCELLANEOUS ITEMS
3090REMOVE AND REPLACE VENTILATOR, ROOFTOPEA1$ - 0
3091REMOVE AND REPLACE VENTILATOR, RIDGELF60$ - 0
3092REMOVE AND REPLACE VENTILATOR, GABLEEA1$ - 0
3093REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHEDEA1$ - 0
3094REMOVE AND REPLACE ROOF SCUTTLEEA1$ - 0
DIV 7 - GUTTERS AND DOWNSPOUTS
3095REMOVE EXISTING GUTTER AND DOWNSPOUTSLF300$ - 0
FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC.
309624 GA. GALVANIZED/PRIMED, 4" X 5"LF50$ - 0
309724 GA. GALVANIZED/PRIMED, 5" X 7"LF200$ - 0
3098ALUMINUM, 4" X 5"LF10$ - 0
3099ALUMINUM, 5" X 7"LF10$ - 0
310016 OZ. COPPER, 4" X 5"LF10$ - 0
310116 OZ. COPPER, 5" X 7"LF10$ - 0
FURNISH AND INSTALL NEW DOWNSPOUTS INCLUDES BRACKETS, ETC.
310224 GA. GALVANIZED/PRIMED, 3" X 4"LF100$ - 0
3103ALUMINUM, 3" X 4"LF10$ - 0
310416 OZ. COPPER, 3" X 4"LF10$ - 0
3105FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKSEA5$ - 0
DIV 7 - MANUFACTURED ROOF FRAMING SYSTEM
3106RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, <=100 SQSQ50$ - 0
3107RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, >100 SQSQ110$ - 0
DIV 7 - STANDING SEAM METAL ROOFING
3108NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL <=100 SQSQ200$ - 0
3109NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQSQ200$ - 0
3110FASCIA PANEL SYSTEMSF1,000$ - 0
3111NON-PERFORATED SOFFIT PANELSF700$ - 0
3112PERFORATED SOFFIT PANELSF300$ - 0
DIV 7 - CAULKING AND SEALANTS
3113REMOVE EXISTING CAULKING / CLEAN JOINTLF150$ - 0
3114SILICONE CAULKING / SEALANTLF150$ - 0
3115CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1 OR APPROVED EQUAL)LF50$ - 0
DIV 9 - PAINTING
3116Reserved
3117PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATSSF500$ - 0
DIV 15 - ROOF DRAINS
3118REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINEREA10$ - 0
3119REMOVE AND REPLACE EXISTING ROOF DRAIN INCLUDES NEW CAST IRON DRAIN AND DOME STRAINER.EA10$ - 0
DIV 16 - LIGHTING PROTECTION
3120REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERSLS3$ - 0
3121REMOVE AND REINSTALL EXISTING CONDUCTORLF300$ - 0
3122REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPSEA100$ - 0
REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTING PROTECTION SYSTEM
3123AIR TERMINALS, INCLUDES COPPER BASEEA10$ - 0
3124CONDUCTORSLF100$ - 0
3125FASTENERS, INCLUDES LOOPS AND CLIPSEA1$ - 0
3126CONNECTORSEA1$ - 0
3127GROUNDING RODSEA1$ - 0
3128SURGE PROTECTIONEA1$ - 0
3129UL SITE INSPECTIONEA1$ - 0
MISCELLANEOUS ROOFING ITEMS
3130EXTEND PLUMBING VENTSLF10$ - 0
3131FLEXIBLE VENT PIPE FLASHING (METAL ROOFS)EA20$ - 0
3132REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR), BUR'sEA30$ - 0
3133REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH NEW COLLAR TYPE FLASHINGEA10$ - 0
3134REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECKSF50$ - 0
3135FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKSSQ10$ - 0
3136FURNISH AND INSTALL ROSIN PAPER OVER WOOD ROOF DECKSSQ1$ - 0
3137DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP)EA1$ - 0
3138REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC.LF50$ - 0
3139ROLL COIL RIDGE VENTLF300$ - 0
314060MIL WATERPROOF UNDERLAYMENTLF100$ - 0
3141SPUD EXISTING ROOF TO INSULATIONSF100$ - 0
3142TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREAEA5$ - 0
ENGINEERING / SUB-CONTRACTORS
3143ENGINEERING RATE STRUCTURALHR20$ - 0
3144MECHANICAL SUBCONTRACTOR (SHEET METAL WORKER)HR20$ - 0
3145ELECTRICAL SUBCONTRACTOR (ELECTRICIAN)HR20$ - 0
3146LABOR RATE - MISCELLANEOUS WORK (SHEET METAL WORKER)MH40$ - 0
SPECIAL CONDITIONS AND CIRCUMSTANCES
3147HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOBEA2$ - 0
MODIFIERS
3148COEFFICIENT % TO BE MULTIPLIED TO TOTAL FOR URGENT DELIVERY ORDER (UDO) - TEMPORARY DRY-IN WORK ONLY35%

TOTAL $ - 0

option 4

OPTION 4DESCRIPTION - SUPPLIES OR SERVICES AND PRICES/COSTS
LINEUNIT PRICE SCHEDULEUnitEST.unit priceTOTAL
ITEMIDIQ REPAIR AND REPLACE ROOFSQTY.
DIV 2 - SELECTIVE DEMOLITION
4001REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BFBF100$ - 0
4002REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BFBF100$ - 0
4003REMOVE AND REPLACE WOOD DECKINGBF10$ - 0
4004REMOVE AND REPLACE PLYWOOD ROOF SHEATHING, 3/4"SF200$ - 0
4005REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, 0-20 BFBF50$ - 0
4006REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, >20 BFBF50$ - 0
4007REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8")BF10$ - 0
DIV 2 - TEAR OFFS
4008DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC (DOES NOT INCLUDE INSULATION)SQ400$ - 0
4009DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3"SQ400$ - 0
4010REMOVE AND DISPOSE OF EXISTING SHINGLE ROOF SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGESSQ100$ - 0
4011REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGESSQ100$ - 0
4012DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEMSQ500$ - 0
DIV 5 - STEEL ROOF DECK
4013REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECKSQ50$ - 0
DIV 7 - INSULATION
4014POLYISOCYANURATE BOARD INSULATION - 1" THICK, R7.14SQ100$ - 0
4015POLYISOCYANURATE BOARD INSULATION - 2" THICK, R14.29SQ100$ - 0
4016POLYISOCYANURATE BOARD INSULATION - 3" THICK, R21.74SQ300$ - 0
4017PERLITE BOARD INSULATION, 3/4" THICK, R2.08, <=100 SQSQ200$ - 0
4018PERLITE BOARD INSULATION, 3/4" THICK, R2.08, >100 SQSQ200$ - 0
4019BATT ROOF INSULATION, R-19SF400$ - 0
4020FIBER CANTSLF250$ - 0
4021WOOD CANTSLF50$ - 0
4022TAPERED FILL INSULATION BOARDBF2,000$ - 0
4023TAPERED 1/4" PER FOOT FOR DRAINAGEBF3,000$ - 0
DIV 7 - SHINGLE ROOFING SYSTEMS
4024FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENTSQ40$ - 0
4025FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL FIBERGLASS SHINGLE SYSTEM INCLUDING UNDERLAYMENTSQ60$ - 0
4026REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRSSQ50$ - 0
4027ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER)SQ30$ - 0
4028FELT, GLASS FIBER, 15 POUND ORGANICSQ10$ - 0
4029FELT, GLASS FIBER, 30 POUND ORGANICSQ30$ - 0
DIV 7 - BITUMINOUS ROOFING (BURS)
40304-PLY BURS USING ASPHALTSQ50$ - 0
40314-PLY BURS USING COAL TARSQ50$ - 0
40324-PLY BURS WITH SBS MODIFIED CAP SHEETSQ100$ - 0
4033REMOVE AND REPLACE PITCH PANEA10$ - 0
DIV 7 - PARTIAL BURS REPAIRS
4034REPAIR BLISTERSSF100$ - 0
4035REPAIR SPLITSSF50$ - 0
4036REPAIR RIDGESSF50$ - 0
4037APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREASSF200$ - 0
DIV 7 - PREPARED ROLL ROOFING
4038FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS PREPARED ROLL ROOFING INCLUDING UNDERLAYMENTSQ100$ - 0
4039CUT-OUT AND PATCH ROLL ROOFINGSQ10$ - 0
DIV 7 - POLYVINYL-CHLORIDE ROOFING (PVC)
4040FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 48 MILSSQ1$ - 0
4041FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 72 MILSSQ1$ - 0
4042FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 60 MILSSQ1$ - 0
4043FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 72 MILSSQ1$ - 0
4044PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUTLF10$ - 0
4045PVC LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUTLF10$ - 0
4046PVC VENT BOOTSEA1$ - 0
4047PVC UNIVERSAL CORNERSEA1$ - 0
4048PATCH AND REPAIR PVC SYSTEMSF10$ - 0
DIV 7 - THERMOPLASTIC POLYOLEFIN ROOFING (TPO)
4049FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 45 MILSSQ1$ - 0
4050FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 60 MILSSQ1$ - 0
4051FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 45 MILSSQ1$ - 0
4052FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 60 MILSSQ1$ - 0
4053TPO LAMINATED METAL FLASHING UP TO 18" STRETCH OUTLF10$ - 0
4054TPO LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUTLF10$ - 0
4055TPO VENT BOOTSEA1$ - 0
4056TPO UNIVERSAL CORNERSEA1$ - 0
4057PATCH AND REPAIR TPO SYSTEMSF10$ - 0
DIV 7 - FLUID APPLIED ROOF COATING SYSTEM, METAL ROOFS
4058FLUID APPLIED COATING SYSTEM FOR METAL ROOFSSQ1$ - 0
DIV 7 - TRAFFIC BEARING ROOF DECK SURFACING
4059TRAFFIC BEARING ROOF DECK SURFACING SYSTEMSQ20$ - 0
DIV 7 - SHEET METAL WORK, GENERAL
FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION)
4060GALVANIZED METAL, 4"-5"LF150$ - 0
4061GALVANIZED METAL, 6"-7"LF150$ - 0
4062ALUMINUM, 4"-5"LF10$ - 0
4063ALUMINUM, 6"-7"LF10$ - 0
4064COPPER, 4"-5"LF10$ - 0
4065COPPER, 6"-7"LF10$ - 0
40662-PIECE GALVANIZED METAL, 7"-10"LF20$ - 0
40672-PIECE GALVANIZED METAL, 10"-12"LF20$ - 0
40682-PIECE ALUMINUM, 7"-10"LF10$ - 0
40692-PIECE ALUMINUM, 10"-12"LF10$ - 0
40702-PIECE COPPER, 7"-10"LF10$ - 0
40712-PIECE COPPER, 10"-12"LF10$ - 0
FURNISH AND INSTALL:
4072GALVANIZED METAL DRIP EDGELF100$ - 0
4073GALVANIZED METAL COUNTERFLASHINGSF200$ - 0
4074GALVANIZED METAL VALLEY FLASHINGSF100$ - 0
4075GALVANIZED METAL STEP FLASHINGSF20$ - 0
4076GALVANIZED METAL BASE FLASHINGSF20$ - 0
4077GALVANIZED METAL FLASHING, FLAT SHEETSF200$ - 0
4078GALVANIZED METAL CAP FLASHINGSF100$ - 0
4079ALUMINUM DRIP EDGELF10$ - 0
4080ALUMINUM COUNTERFLASHINGSF10$ - 0
4081ALUMINUM VALLEY FLASHINGSF10$ - 0
4082ALUMINUM STEP FLASHINGSF10$ - 0
4083ALUMINUM BASE FLASHINGSF10$ - 0
4084ALUMINUM FLASHING, FLAT SHEETSF10$ - 0
4085ALUMINUM CAP FLASHINGSF10$ - 0
4086METAL RIDGE VENT/CAPLF1000$ - 0
REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT
4087ELASTOMERIC TYPE (NEOPRENE BELLOWS)LF50$ - 0
4088ALUMINUM CAPPED CURBLF10$ - 0
4089GALVANIZED CAPPED CURBLF50$ - 0
MISCELLANEOUS ITEMS
4090REMOVE AND REPLACE VENTILATOR, ROOFTOPEA1$ - 0
4091REMOVE AND REPLACE VENTILATOR, RIDGELF60$ - 0
4092REMOVE AND REPLACE VENTILATOR, GABLEEA1$ - 0
4093REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHEDEA1$ - 0
4094REMOVE AND REPLACE ROOF SCUTTLEEA1$ - 0
DIV 7 - GUTTERS AND DOWNSPOUTS
4095REMOVE EXISTING GUTTER AND DOWNSPOUTSLF300$ - 0
FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC.
409624 GA. GALVANIZED/PRIMED, 4" X 5"LF50$ - 0
409724 GA. GALVANIZED/PRIMED, 5" X 7"LF200$ - 0
4098ALUMINUM, 4" X 5"LF10$ - 0
4099ALUMINUM, 5" X 7"LF10$ - 0
410016 OZ. COPPER, 4" X 5"LF10$ - 0
410116 OZ. COPPER, 5" X 7"LF10$ - 0
FURNISH AND INSTALL NEW DOWNSPOUTS INCLUDES BRACKETS, ETC.
410224 GA. GALVANIZED/PRIMED, 3" X 4"LF100$ - 0
4103ALUMINUM, 3" X 4"LF10$ - 0
410416 OZ. COPPER, 3" X 4"LF10$ - 0
4105FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKSEA5$ - 0
DIV 7 - MANUFACTURED ROOF FRAMING SYSTEM
4106RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, <=100 SQSQ50$ - 0
4107RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, >100 SQSQ110$ - 0
DIV 7 - STANDING SEAM METAL ROOFING
4108NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL <=100 SQSQ200$ - 0
4109NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQSQ200$ - 0
4110FASCIA PANEL SYSTEMSF1,000$ - 0
4111NON-PERFORATED SOFFIT PANELSF700$ - 0
4112PERFORATED SOFFIT PANELSF300$ - 0
DIV 7 - CAULKING AND SEALANTS
4113REMOVE EXISTING CAULKING / CLEAN JOINTLF150$ - 0
4114SILICONE CAULKING / SEALANTLF150$ - 0
4115CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1 OR APPROVED EQUAL)LF50$ - 0
DIV 9 - PAINTING
4116Reserved
4117PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATSSF500$ - 0
DIV 15 - ROOF DRAINS
4118REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINEREA10$ - 0
4119REMOVE AND REPLACE EXISTING ROOF DRAIN INCLUDES NEW CAST IRON DRAIN AND DOME STRAINER.EA10$ - 0
DIV 16 - LIGHTING PROTECTION
4120REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERSLS3$ - 0

This is the start of the file's text. The full file is on GovTribe.