2006 BASE YEAR
| Base Year | DESCRIPTION - SUPPLIES OR SERVICES AND PRICES/COSTS | Date: 30 Jun 2010 | |||
| LINE | UNIT PRICE SCHEDULE | Unit | EST. | ||
| ITEM | IDIQ REPAIR AND REPLACE ROOFS | QTY. | UNIT PRICE | TOTAL | |
| DIV 2 - SELECTIVE DEMOLITION | |||||
| 0001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF | BF | 100 | ||
| 0002 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BF | BF | 100 | ||
| 0003 | REMOVE AND REPLACE WOOD DECKING | BF | 10 | ||
| 0004 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING, 3/4" | SF | 200 | ||
| 0005 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, 0-20 BF | BF | 50 | ||
| 0006 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, >20 BF | BF | 50 | ||
| 0007 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | BF | 10 | ||
| DIV 2 - TEAR OFFS | |||||
| 0008 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC (DOES NOT INCLUDE INSULATION) | SQ | 400 | ||
| 0009 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3" | SQ | 400 | ||
| 0010 | REMOVE AND DISPOSE OF EXISTING SHINGLE ROOF SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | ||
| 0011 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | ||
| 0012 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 500 | ||
| DIV 5 - STEEL ROOF DECK | |||||
| 0013 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 50 | ||
| DIV 7 - INSULATION | |||||
| 0014 | POLYISOCYANURATE BOARD INSULATION - 1" THICK, MIN. R- 6.5 | SQ | 100 | ||
| 0015 | POLYISOCYANURATE BOARD INSULATION - 2" THICK, MIN R-13.0 | SQ | 100 | ||
| 0016 | POLYISOCYANURATE BOARD INSULATION - 3" THICK, MIN R-19.0 | SQ | 300 | ||
| 0017 | PERLITE BOARD INSULATION, 3/4" THICK, R2.08, <=100 SQ | SQ | 200 | ||
| 0018 | PERLITE BOARD INSULATION, 3/4" THICK, R2.08, >100 SQ | SQ | 200 | ||
| 0019 | METAL BUILDING ROOF INSULATION R-30 | SF | 400 | ||
| 0020 | FIBER CANTS | LF | 250 | ||
| 0021 | WOOD CANTS | LF | 50 | ||
| 0022 | TAPERED FILL INSULATION BOARD | BF | 2,000 | ||
| 0023 | TAPERED 1/4" PER FOOT FOR DRAINAGE | BF | 3,000 | ||
| DIV 7 - SHINGLE ROOFING SYSTEMS | |||||
| 0024 | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 40 | ||
| 0025 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL FIBERGLASS SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 60 | ||
| 0026 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 50 | ||
| 0027 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 30 | ||
| 0028 | FELT, GLASS FIBER, 15 POUND ORGANIC | SQ | 10 | ||
| 0029 | FELT, GLASS FIBER, 30 POUND ORGANIC | SQ | 30 | ||
| DIV 7 - BITUMINOUS ROOFING (BURS) | |||||
| 0030 | 4-PLY BURS USING ASPHALT | SQ | 50 | ||
| 0031 | 4-PLY BURS USING COAL TAR | SQ | 50 | ||
| 0032 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 100 | ||
| 0033 | REMOVE AND REPLACE PITCH PAN | EA | 10 | ||
| DIV 7 - PARTIAL BURS REPAIRS | |||||
| 0034 | REPAIR BLISTERS | SF | 100 | ||
| 0035 | REPAIR SPLITS | SF | 50 | ||
| 0036 | REPAIR RIDGES | SF | 50 | ||
| 0037 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 200 | ||
| DIV 7 - PREPARED ROLL ROOFING | |||||
| 0038 | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS PREPARED ROLL ROOFING INCLUDING UNDERLAYMENT | SQ | 100 | ||
| 0039 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 10 | ||
| DIV 7 - POLYVINYL-CHLORIDE ROOFING (PVC) | |||||
| 0040 | FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 48 MILS | SQ | 1 | ||
| 0041 | FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 72 MILS | SQ | 1 | ||
| 00042 | FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 60 MILS | SQ | 1 | ||
| 0043 | FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 72 MILS | SQ | 1 | ||
| 0044 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 10 | ||
| 0045 | PVC LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUT | LF | 10 | ||
| 0046 | PVC VENT BOOTS | EA | 1 | ||
| 0047 | PVC UNIVERSAL CORNERS | EA | 1 | ||
| 0048 | PATCH AND REPAIR PVC SYSTEM | SF | 10 | ||
| DIV 7 - THERMOPLASTIC POLYOLEFIN ROOFING (TPO) | |||||
| 0049 | FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 45 MILS | SQ | 1 | ||
| 0050 | FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 60 MILS | SQ | 1 | ||
| 0051 | FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 45 MILS | SQ | 1 | ||
| 0052 | FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 60 MILS | SQ | 1 | ||
| 0053 | TPO LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 10 | ||
| 0054 | TPO LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUT | LF | 10 | ||
| 0055 | TPO VENT BOOTS | EA | 1 | ||
| 0056 | TPO UNIVERSAL CORNERS | EA | 1 | ||
| 0057 | PATCH AND REPAIR TPO SYSTEM | SF | 10 | ||
| DIV 7 - FLUID APPLIED ROOF COATING SYSTEM, METAL ROOFS | |||||
| 0058 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 1 | ||
| DIV 7 - TRAFFIC BEARING ROOF DECK SURFACING | |||||
| 0059 | TRAFFIC BEARING ROOF DECK SURFACING SYSTEM | SQ | 20 | ||
| DIV 7 - SHEET METAL WORK, GENERAL | |||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | |||||
| 0060 | GALVANIZED METAL, 4"-5" | LF | 150 | ||
| 0061 | GALVANIZED METAL, 6"-7" | LF | 150 | ||
| 0062 | ALUMINUM, 4"-5" | LF | 10 | ||
| 0063 | ALUMINUM, 6"-7" | LF | 10 | ||
| 0064 | COPPER, 4"-5" | LF | 10 | ||
| 0065 | COPPER, 6"-7" | LF | 10 | ||
| 0066 | 2-PIECE GALVANIZED METAL, 7"-10" | LF | 20 | ||
| 0067 | 2-PIECE GALVANIZED METAL, 10"-12" | LF | 20 | ||
| 0068 | 2-PIECE ALUMINUM, 7"-10" | LF | 10 | ||
| 0069 | 2-PIECE ALUMINUM, 10"-12" | LF | 10 | ||
| 0070 | 2-PIECE COPPER, 7"-10" | LF | 10 | ||
| 0071 | 2-PIECE COPPER, 10"-12" | LF | 10 | ||
| FURNISH AND INSTALL: | |||||
| 0072 | GALVANIZED METAL DRIP EDGE | LF | 100 | ||
| 0073 | GALVANIZED METAL COUNTERFLASHING | SF | 200 | ||
| 0074 | GALVANIZED METAL VALLEY FLASHING | SF | 100 | ||
| 0075 | GALVANIZED METAL STEP FLASHING | SF | 20 | ||
| 0076 | GALVANIZED METAL BASE FLASHING | SF | 20 | ||
| 0077 | GALVANIZED METAL FLASHING, FLAT SHEET | SF | 200 | ||
| 0078 | GALVANIZED METAL CAP FLASHING | SF | 100 | ||
| 0079 | ALUMINUM DRIP EDGE | LF | 10 | ||
| 0080 | ALUMINUM COUNTERFLASHING | SF | 10 | ||
| 0081 | ALUMINUM VALLEY FLASHING | SF | 10 | ||
| 0082 | ALUMINUM STEP FLASHING | SF | 10 | ||
| 0083 | ALUMINUM BASE FLASHING | SF | 10 | ||
| 0084 | ALUMINUM FLASHING, FLAT SHEET | SF | 10 | ||
| 0085 | ALUMINUM CAP FLASHING | SF | 10 | ||
| 0086 | METAL RIDGE VENT/CAP | LF | 1000 | ||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT | |||||
| 0087 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 50 | ||
| 0088 | ALUMINUM CAPPED CURB | LF | 10 | ||
| 0089 | GALVANIZED CAPPED CURB | LF | 50 | ||
| MISCELLANEOUS ITEMS | |||||
| 0090 | REMOVE AND REPLACE VENTILATOR, ROOFTOP | EA | 1 | ||
| 0091 | REMOVE AND REPLACE VENTILATOR, RIDGE | LF | 60 | ||
| 0092 | REMOVE AND REPLACE VENTILATOR, GABLE | EA | 1 | ||
| 0093 | REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHED | EA | 1 | ||
| 0094 | REMOVE AND REPLACE ROOF SCUTTLE | EA | 1 | ||
| DIV 7 - GUTTERS AND DOWNSPOUTS | |||||
| 0095 | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 300 | ||
| FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC. | |||||
| 0096 | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 50 | ||
| 0097 | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 200 | ||
| 0098 | ALUMINUM, 4" X 5" | LF | 10 | ||
| 0099 | ALUMINUM, 5" X 7" | LF | 10 | ||
| 0100 | 16 OZ. COPPER, 4" X 5" | LF | 10 | ||
| 0101 | 16 OZ. COPPER, 5" X 7" | LF | 10 | ||
| FURNISH AND INSTALL NEW DOWNSPOUTS INCLUDES BRACKETS, ETC. | |||||
| 0102 | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 100 | ||
| 0103 | ALUMINUM, 3" X 4" | LF | 10 | ||
| 0104 | 16 OZ. COPPER, 3" X 4" | LF | 10 | ||
| 0105 | FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 5 | ||
| DIV 7 - MANUFACTURED ROOF FRAMING SYSTEM | |||||
| 0106 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, <=100 SQ | SQ | 50 | ||
| 0107 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, >100 SQ | SQ | 110 | ||
| DIV 7 - STANDING SEAM METAL ROOFING | |||||
| 0108 | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL <=100 SQ | SQ | 200 | ||
| 0109 | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQ | SQ | 200 | ||
| 0110 | FASCIA PANEL SYSTEM | SF | 1,000 | ||
| 0111 | NON-PERFORATED SOFFIT PANEL | SF | 700 | ||
| 0112 | PERFORATED SOFFIT PANEL | SF | 300 | ||
| DIV 7 - CAULKING AND SEALANTS | |||||
| 0113 | REMOVE EXISTING CAULKING / CLEAN JOINT | LF | 150 | ||
| 0114 | SILICONE CAULKING / SEALANT | LF | 150 | ||
| 0115 | CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1 OR APPROVED EQUAL) | LF | 50 | ||
| DIV 9 - PAINTING | |||||
| 0116 | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | |||
| 0117 | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 500 | ||
| DIV 15 - ROOF DRAINS | |||||
| 0118 | REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 10 | ||
| 0119 | REMOVE AND REPLACE EXISTING ROOF DRAIN INCLUDES NEW CAST IRON DRAIN AND DOME STRAINER. | EA | 10 | ||
| DIV 16 - LIGHTING PROTECTION | |||||
| 0120 | REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERS | LS | 3 | ||
| 0121 | REMOVE AND REINSTALL EXISTING CONDUCTOR | LF | 300 | ||
| 0122 | REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPS | EA | 100 | ||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTING PROTECTION SYSTEM | |||||
| 0123 | AIR TERMINALS, INCLUDES COPPER BASE | EA | 10 | ||
| 0124 | CONDUCTORS | LF | 100 | ||
| 0125 | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 1 | ||
| 0126 | CONNECTORS | EA | 1 | ||
| 0127 | GROUNDING RODS | EA | 1 | ||
| 0128 | SURGE PROTECTION | EA | 1 | ||
| 0129 | UL SITE INSPECTION | EA | 1 | ||
| MISCELLANEOUS ROOFING ITEMS | |||||
| 0130 | EXTEND PLUMBING VENTS | LF | 10 | ||
| 0131 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 20 | ||
| 0132 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR), BUR's | EA | 30 | ||
| 0133 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH NEW COLLAR TYPE FLASHING | EA | 10 | ||
| 0134 | REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 50 | ||
| 0135 | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKS | SQ | 10 | ||
| 0136 | FURNISH AND INSTALL ROSIN PAPER OVER WOOD ROOF DECKS | SQ | 1 | ||
| 0137 | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP) | EA | 1 | ||
| 0138 | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 50 | ||
| 0139 | ROLL COIL RIDGE VENT | LF | 300 | ||
| 0140 | 60MIL WATERPROOF UNDERLAYMENT | LF | 100 | ||
| 0141 | SPUD EXISTING ROOF TO INSULATION | SF | 100 | ||
| 0142 | TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA | EA | 5 | ||
| ENGINEERING / SUB-CONTRACTORS | |||||
| 0143 | ENGINEERING RATE STRUCTURAL | HR | 20 | ||
| 0144 | MECHANICAL SUBCONTRACTOR (SHEET METAL WORKER) | HR | 20 | ||
| 0145 | ELECTRICAL SUBCONTRACTOR (ELECTRICIAN) | HR | 20 | ||
| 0146 | LABOR RATE - MISCELLANEOUS WORK (SHEET METAL WORKER) | MH | 40 | ||
| SPECIAL CONDITIONS AND CIRCUMSTANCES | |||||
| 0147 | HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOB | EA | 2 | ||
| MODIFIERS | |||||
| 0148 | COEFFICIENT % TO BE MULTIPLIED TO TOTAL FOR URGENT DELIVERY ORDER (UDO) - TEMPORARY DRY-IN WORK ONLY | 35% |
TOTAL
BASIC YEAR FA4417-10-R-0012, Attachment 1 Bid Schedule
&P of &N ATTACHMENT 1 &D
Option Yr 1
| OPT YR 1 | DESCRIPTION - SUPPLIES OR SERVICES AND PRICES/COSTS | Date: 30 Jun 2010 | |||
| LINE | UNIT PRICE SCHEDULE | Unit | EST. | ||
| ITEM | IDIQ REPAIR AND REPLACE ROOFS | QTY. | UNIT PRICE | TOTAL | |
| DIV 2 - SELECTIVE DEMOLITION | |||||
| 1001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF | BF | 100 | ||
| 1002 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BF | BF | 100 | ||
| 1003 | REMOVE AND REPLACE WOOD DECKING | BF | 10 | ||
| 1004 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING, 3/4" | SF | 200 | ||
| 1005 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, 0-20 BF | BF | 50 | ||
| 1006 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, >20 BF | BF | 50 | ||
| 1007 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | BF | 10 | ||
| DIV 2 - TEAR OFFS | |||||
| 1008 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC (DOES NOT INCLUDE INSULATION) | SQ | 400 | ||
| 1009 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3" | SQ | 400 | ||
| 1010 | REMOVE AND DISPOSE OF EXISTING SHINGLE ROOF SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | ||
| 1011 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | ||
| 1012 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 500 | ||
| DIV 5 - STEEL ROOF DECK | |||||
| 1013 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 50 | ||
| DIV 7 - INSULATION | |||||
| 1014 | POLYISOCYANURATE BOARD INSULATION - 1" THICK, MIN. R- 6.5 | SQ | 100 | ||
| 1015 | POLYISOCYANURATE BOARD INSULATION - 2" THICK, MIN R-13.0 | SQ | 100 | ||
| 1016 | POLYISOCYANURATE BOARD INSULATION - 3" THICK, MIN R-19.0 | SQ | 300 | ||
| 1017 | PERLITE BOARD INSULATION, 3/4" THICK, R2.08, <=100 SQ | SQ | 200 | ||
| 1018 | PERLITE BOARD INSULATION, 3/4" THICK, R2.08, >100 SQ | SQ | 200 | ||
| 1019 | METAL BUILDING ROOF INSULATION R-30 | SF | 400 | ||
| 1020 | FIBER CANTS | LF | 250 | ||
| 1021 | WOOD CANTS | LF | 50 | ||
| 1022 | TAPERED FILL INSULATION BOARD | BF | 2,000 | ||
| 1023 | TAPERED 1/4" PER FOOT FOR DRAINAGE | BF | 3,000 | ||
| DIV 7 - SHINGLE ROOFING SYSTEMS | |||||
| 1024 | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 40 | ||
| 1025 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL FIBERGLASS SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 60 | ||
| 1026 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 50 | ||
| 1027 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 30 | ||
| 1028 | FELT, GLASS FIBER, 15 POUND ORGANIC | SQ | 10 | ||
| 1029 | FELT, GLASS FIBER, 30 POUND ORGANIC | SQ | 30 | ||
| DIV 7 - BITUMINOUS ROOFING (BURS) | |||||
| 1030 | 4-PLY BURS USING ASPHALT | SQ | 50 | ||
| 1031 | 4-PLY BURS USING COAL TAR | SQ | 50 | ||
| 1032 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 100 | ||
| 1033 | REMOVE AND REPLACE PITCH PAN | EA | 10 | ||
| DIV 7 - PARTIAL BURS REPAIRS | |||||
| 1034 | REPAIR BLISTERS | SF | 100 | ||
| 1035 | REPAIR SPLITS | SF | 50 | ||
| 1036 | REPAIR RIDGES | SF | 50 | ||
| 1037 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 200 | ||
| DIV 7 - PREPARED ROLL ROOFING | |||||
| 1038 | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS PREPARED ROLL ROOFING INCLUDING UNDERLAYMENT | SQ | 100 | ||
| 1039 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 10 | ||
| DIV 7 - POLYVINYL-CHLORIDE ROOFING (PVC) | |||||
| 1040 | FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 48 MILS | SQ | 1 | ||
| 1041 | FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 72 MILS | SQ | 1 | ||
| 1042 | FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 60 MILS | SQ | 1 | ||
| 1043 | FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 72 MILS | SQ | 1 | ||
| 1044 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 10 | ||
| 1045 | PVC LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUT | LF | 10 | ||
| 1046 | PVC VENT BOOTS | EA | 1 | ||
| 1047 | PVC UNIVERSAL CORNERS | EA | 1 | ||
| 1048 | PATCH AND REPAIR PVC SYSTEM | SF | 10 | ||
| DIV 7 - THERMOPLASTIC POLYOLEFIN ROOFING (TPO) | |||||
| 1049 | FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 45 MILS | SQ | 1 | ||
| 1050 | FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 60 MILS | SQ | 1 | ||
| 1051 | FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 45 MILS | SQ | 1 | ||
| 1052 | FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 60 MILS | SQ | 1 | ||
| 1053 | TPO LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 10 | ||
| 1054 | TPO LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUT | LF | 10 | ||
| 1055 | TPO VENT BOOTS | EA | 1 | ||
| 1056 | TPO UNIVERSAL CORNERS | EA | 1 | ||
| 1057 | PATCH AND REPAIR TPO SYSTEM | SF | 10 | ||
| DIV 7 - FLUID APPLIED ROOF COATING SYSTEM, METAL ROOFS | |||||
| 1058 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 1 | ||
| DIV 7 - TRAFFIC BEARING ROOF DECK SURFACING | |||||
| 1059 | TRAFFIC BEARING ROOF DECK SURFACING SYSTEM | SQ | 20 | ||
| DIV 7 - SHEET METAL WORK, GENERAL | |||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | |||||
| 1060 | GALVANIZED METAL, 4"-5" | LF | 150 | ||
| 1061 | GALVANIZED METAL, 6"-7" | LF | 150 | ||
| 1062 | ALUMINUM, 4"-5" | LF | 10 | ||
| 1063 | ALUMINUM, 6"-7" | LF | 10 | ||
| 1064 | COPPER, 4"-5" | LF | 10 | ||
| 1065 | COPPER, 6"-7" | LF | 10 | ||
| 1066 | 2-PIECE GALVANIZED METAL, 7"-10" | LF | 20 | ||
| 1067 | 2-PIECE GALVANIZED METAL, 10"-12" | LF | 20 | ||
| 1068 | 2-PIECE ALUMINUM, 7"-10" | LF | 10 | ||
| 1069 | 2-PIECE ALUMINUM, 10"-12" | LF | 10 | ||
| 1070 | 2-PIECE COPPER, 7"-10" | LF | 10 | ||
| 1071 | 2-PIECE COPPER, 10"-12" | LF | 10 | ||
| FURNISH AND INSTALL: | |||||
| 1072 | GALVANIZED METAL DRIP EDGE | LF | 100 | ||
| 1073 | GALVANIZED METAL COUNTERFLASHING | SF | 200 | ||
| 1074 | GALVANIZED METAL VALLEY FLASHING | SF | 100 | ||
| 1075 | GALVANIZED METAL STEP FLASHING | SF | 20 | ||
| 1076 | GALVANIZED METAL BASE FLASHING | SF | 20 | ||
| 1077 | GALVANIZED METAL FLASHING, FLAT SHEET | SF | 200 | ||
| 1078 | GALVANIZED METAL CAP FLASHING | SF | 100 | ||
| 1079 | ALUMINUM DRIP EDGE | LF | 10 | ||
| 1080 | ALUMINUM COUNTERFLASHING | SF | 10 | ||
| 1081 | ALUMINUM VALLEY FLASHING | SF | 10 | ||
| 1082 | ALUMINUM STEP FLASHING | SF | 10 | ||
| 1083 | ALUMINUM BASE FLASHING | SF | 10 | ||
| 1084 | ALUMINUM FLASHING, FLAT SHEET | SF | 10 | ||
| 1085 | ALUMINUM CAP FLASHING | SF | 10 | ||
| 1086 | METAL RIDGE VENT/CAP | LF | 1000 | ||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT | |||||
| 1087 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 50 | ||
| 1088 | ALUMINUM CAPPED CURB | LF | 10 | ||
| 1089 | GALVANIZED CAPPED CURB | LF | 50 | ||
| MISCELLANEOUS ITEMS | |||||
| 1090 | REMOVE AND REPLACE VENTILATOR, ROOFTOP | EA | 1 | ||
| 1091 | REMOVE AND REPLACE VENTILATOR, RIDGE | LF | 60 | ||
| 1092 | REMOVE AND REPLACE VENTILATOR, GABLE | EA | 1 | ||
| 1093 | REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHED | EA | 1 | ||
| 1094 | REMOVE AND REPLACE ROOF SCUTTLE | EA | 1 | ||
| DIV 7 - GUTTERS AND DOWNSPOUTS | |||||
| 1095 | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 300 | ||
| FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC. | |||||
| 1096 | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 50 | ||
| 1097 | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 200 | ||
| 1098 | ALUMINUM, 4" X 5" | LF | 10 | ||
| 1099 | ALUMINUM, 5" X 7" | LF | 10 | ||
| 1100 | 16 OZ. COPPER, 4" X 5" | LF | 10 | ||
| 1101 | 16 OZ. COPPER, 5" X 7" | LF | 10 | ||
| FURNISH AND INSTALL NEW DOWNSPOUTS INCLUDES BRACKETS, ETC. | |||||
| 1102 | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 100 | ||
| 1103 | ALUMINUM, 3" X 4" | LF | 10 | ||
| 1104 | 16 OZ. COPPER, 3" X 4" | LF | 10 | ||
| 1105 | FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 5 | ||
| DIV 7 - MANUFACTURED ROOF FRAMING SYSTEM | |||||
| 1106 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, <=100 SQ | SQ | 50 | ||
| 1107 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, >100 SQ | SQ | 110 | ||
| DIV 7 - STANDING SEAM METAL ROOFING | |||||
| 1108 | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL <=100 SQ | SQ | 200 | ||
| 1109 | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQ | SQ | 200 | ||
| 1110 | FASCIA PANEL SYSTEM | SF | 1,000 | ||
| 1111 | NON-PERFORATED SOFFIT PANEL | SF | 700 | ||
| 1112 | PERFORATED SOFFIT PANEL | SF | 300 | ||
| DIV 7 - CAULKING AND SEALANTS | |||||
| 1113 | REMOVE EXISTING CAULKING / CLEAN JOINT | LF | 150 | ||
| 1114 | SILICONE CAULKING / SEALANT | LF | 150 | ||
| 1115 | CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1 OR APPROVED EQUAL) | LF | 50 | ||
| DIV 9 - PAINTING | |||||
| 1116 | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | |||
| 1117 | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 500 | ||
| DIV 15 - ROOF DRAINS | |||||
| 1118 | REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 10 | ||
| 1119 | REMOVE AND REPLACE EXISTING ROOF DRAIN INCLUDES NEW CAST IRON DRAIN AND DOME STRAINER. | EA | 10 | ||
| DIV 16 - LIGHTING PROTECTION | |||||
| 1120 | REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERS | LS | 3 | ||
| 1121 | REMOVE AND REINSTALL EXISTING CONDUCTOR | LF | 300 | ||
| 1122 | REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPS | EA | 100 | ||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTING PROTECTION SYSTEM | |||||
| 1123 | AIR TERMINALS, INCLUDES COPPER BASE | EA | 10 | ||
| 1124 | CONDUCTORS | LF | 100 | ||
| 1125 | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 1 | ||
| 1126 | CONNECTORS | EA | 1 | ||
| 1127 | GROUNDING RODS | EA | 1 | ||
| 1128 | SURGE PROTECTION | EA | 1 | ||
| 1129 | UL SITE INSPECTION | EA | 1 | ||
| MISCELLANEOUS ROOFING ITEMS | |||||
| 1130 | EXTEND PLUMBING VENTS | LF | 10 | ||
| 1131 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 20 | ||
| 1132 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR), BUR's | EA | 30 | ||
| 1133 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH NEW COLLAR TYPE FLASHING | EA | 10 | ||
| 1134 | REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 50 | ||
| 1135 | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKS | SQ | 10 | ||
| 1136 | FURNISH AND INSTALL ROSIN PAPER OVER WOOD ROOF DECKS | SQ | 1 | ||
| 1137 | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP) | EA | 1 | ||
| 1138 | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 50 | ||
| 1139 | ROLL COIL RIDGE VENT | LF | 300 | ||
| 1140 | 60MIL WATERPROOF UNDERLAYMENT | LF | 100 | ||
| 1141 | SPUD EXISTING ROOF TO INSULATION | SF | 100 | ||
| 1142 | TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA | EA | 5 | ||
| ENGINEERING / SUB-CONTRACTORS | |||||
| 1143 | ENGINEERING RATE STRUCTURAL | HR | 20 | ||
| 1144 | MECHANICAL SUBCONTRACTOR (SHEET METAL WORKER) | HR | 20 | ||
| 1145 | ELECTRICAL SUBCONTRACTOR (ELECTRICIAN) | HR | 20 | ||
| 1146 | LABOR RATE - MISCELLANEOUS WORK (SHEET METAL WORKER) | MH | 40 | ||
| SPECIAL CONDITIONS AND CIRCUMSTANCES | |||||
| 1147 | HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOB | EA | 2 | ||
| MODIFIERS | |||||
| 1148 | COEFFICIENT % TO BE MULTIPLIED TO TOTAL FOR URGENT DELIVERY ORDER (UDO) - TEMPORARY DRY-IN WORK ONLY | 35% |
TOTAL OPTION YEAR 1
OPTION YEAR 1 FA4417-10-R-0012, Attachment 1 Bid Schedule
&P of &N ATTACHMENT 1 &D
Option Yr 2
| OPT YR 2 | DESCRIPTION - SUPPLIES OR SERVICES AND PRICES/COSTS | Date: 30 Jun 2010 | |||
| LINE | UNIT PRICE SCHEDULE | Unit | EST. | ||
| ITEM | IDIQ REPAIR AND REPLACE ROOFS | QTY. | UNIT PRICE | TOTAL | |
| DIV 2 - SELECTIVE DEMOLITION | |||||
| 2001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF | BF | 100 | ||
| 2002 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BF | BF | 100 | ||
| 2003 | REMOVE AND REPLACE WOOD DECKING | BF | 10 | ||
| 2004 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING, 3/4" | SF | 200 | ||
| 2005 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, 0-20 BF | BF | 50 | ||
| 2006 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, >20 BF | BF | 50 | ||
| 2007 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | BF | 10 | ||
| DIV 2 - TEAR OFFS | |||||
| 2008 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC (DOES NOT INCLUDE INSULATION) | SQ | 400 | ||
| 2009 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3" | SQ | 400 | ||
| 2010 | REMOVE AND DISPOSE OF EXISTING SHINGLE ROOF SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | ||
| 2011 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | ||
| 2012 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 500 | ||
| DIV 5 - STEEL ROOF DECK | |||||
| 2013 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 50 | ||
| DIV 7 - INSULATION | |||||
| 2014 | POLYISOCYANURATE BOARD INSULATION - 1" THICK, MIN. R- 6.5 | SQ | 100 | ||
| 2015 | POLYISOCYANURATE BOARD INSULATION - 2" THICK, MIN R-13.0 | SQ | 100 | ||
| 2016 | POLYISOCYANURATE BOARD INSULATION - 3" THICK, MIN R-19.0 | SQ | 300 | ||
| 2017 | PERLITE BOARD INSULATION, 3/4" THICK, R2.08, <=100 SQ | SQ | 200 | ||
| 2018 | PERLITE BOARD INSULATION, 3/4" THICK, R2.08, >100 SQ | SQ | 200 | ||
| 2019 | METAL BUILDING ROOF INSULATION R-30 | SF | 400 | ||
| 2020 | FIBER CANTS | LF | 250 | ||
| 2021 | WOOD CANTS | LF | 50 | ||
| 2022 | TAPERED FILL INSULATION BOARD | BF | 2,000 | ||
| 2023 | TAPERED 1/4" PER FOOT FOR DRAINAGE | BF | 3,000 | ||
| DIV 7 - SHINGLE ROOFING SYSTEMS | |||||
| 2024 | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 40 | ||
| 2025 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL FIBERGLASS SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 60 | ||
| 2026 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 50 | ||
| 2027 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 30 | ||
| 2028 | FELT, GLASS FIBER, 15 POUND ORGANIC | SQ | 10 | ||
| 2029 | FELT, GLASS FIBER, 30 POUND ORGANIC | SQ | 30 | ||
| DIV 7 - BITUMINOUS ROOFING (BURS) | |||||
| 2030 | 4-PLY BURS USING ASPHALT | SQ | 50 | ||
| 2031 | 4-PLY BURS USING COAL TAR | SQ | 50 | ||
| 2032 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 100 | ||
| 2033 | REMOVE AND REPLACE PITCH PAN | EA | 10 | ||
| DIV 7 - PARTIAL BURS REPAIRS | |||||
| 2034 | REPAIR BLISTERS | SF | 100 | ||
| 2035 | REPAIR SPLITS | SF | 50 | ||
| 2036 | REPAIR RIDGES | SF | 50 | ||
| 2037 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 200 | ||
| DIV 7 - PREPARED ROLL ROOFING | |||||
| 2038 | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS PREPARED ROLL ROOFING INCLUDING UNDERLAYMENT | SQ | 100 | ||
| 2039 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 10 | ||
| DIV 7 - POLYVINYL-CHLORIDE ROOFING (PVC) | |||||
| 2040 | FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 48 MILS | SQ | 1 | ||
| 2041 | FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 72 MILS | SQ | 1 | ||
| 2042 | FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 60 MILS | SQ | 1 | ||
| 2043 | FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 72 MILS | SQ | 1 | ||
| 2044 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 10 | ||
| 2045 | PVC LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUT | LF | 10 | ||
| 2046 | PVC VENT BOOTS | EA | 1 | ||
| 2047 | PVC UNIVERSAL CORNERS | EA | 1 | ||
| 2048 | PATCH AND REPAIR PVC SYSTEM | SF | 10 | ||
| DIV 7 - THERMOPLASTIC POLYOLEFIN ROOFING (TPO) | |||||
| 2049 | FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 45 MILS | SQ | 1 | ||
| 2050 | FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 60 MILS | SQ | 1 | ||
| 2051 | FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 45 MILS | SQ | 1 | ||
| 2052 | FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 60 MILS | SQ | 1 | ||
| 2053 | TPO LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 10 | ||
| 2054 | TPO LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUT | LF | 10 | ||
| 2055 | TPO VENT BOOTS | EA | 1 | ||
| 2056 | TPO UNIVERSAL CORNERS | EA | 1 | ||
| 2057 | PATCH AND REPAIR TPO SYSTEM | SF | 10 | ||
| DIV 7 - FLUID APPLIED ROOF COATING SYSTEM, METAL ROOFS | |||||
| 2058 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 1 | ||
| DIV 7 - TRAFFIC BEARING ROOF DECK SURFACING | |||||
| 2059 | TRAFFIC BEARING ROOF DECK SURFACING SYSTEM | SQ | 20 | ||
| DIV 7 - SHEET METAL WORK, GENERAL | |||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | |||||
| 2060 | GALVANIZED METAL, 4"-5" | LF | 150 | ||
| 2061 | GALVANIZED METAL, 6"-7" | LF | 150 | ||
| 2062 | ALUMINUM, 4"-5" | LF | 10 | ||
| 2063 | ALUMINUM, 6"-7" | LF | 10 | ||
| 2064 | COPPER, 4"-5" | LF | 10 | ||
| 2065 | COPPER, 6"-7" | LF | 10 | ||
| 2066 | 2-PIECE GALVANIZED METAL, 7"-10" | LF | 20 | ||
| 2067 | 2-PIECE GALVANIZED METAL, 10"-12" | LF | 20 | ||
| 2068 | 2-PIECE ALUMINUM, 7"-10" | LF | 10 | ||
| 2069 | 2-PIECE ALUMINUM, 10"-12" | LF | 10 | ||
| 2070 | 2-PIECE COPPER, 7"-10" | LF | 10 | ||
| 2071 | 2-PIECE COPPER, 10"-12" | LF | 10 | ||
| FURNISH AND INSTALL: | |||||
| 2072 | GALVANIZED METAL DRIP EDGE | LF | 100 | ||
| 2073 | GALVANIZED METAL COUNTERFLASHING | SF | 200 | ||
| 2074 | GALVANIZED METAL VALLEY FLASHING | SF | 100 | ||
| 2075 | GALVANIZED METAL STEP FLASHING | SF | 20 | ||
| 2076 | GALVANIZED METAL BASE FLASHING | SF | 20 | ||
| 2077 | GALVANIZED METAL FLASHING, FLAT SHEET | SF | 200 | ||
| 2078 | GALVANIZED METAL CAP FLASHING | SF | 100 | ||
| 2079 | ALUMINUM DRIP EDGE | LF | 10 | ||
| 2080 | ALUMINUM COUNTERFLASHING | SF | 10 | ||
| 2081 | ALUMINUM VALLEY FLASHING | SF | 10 | ||
| 2082 | ALUMINUM STEP FLASHING | SF | 10 | ||
| 2083 | ALUMINUM BASE FLASHING | SF | 10 | ||
| 2084 | ALUMINUM FLASHING, FLAT SHEET | SF | 10 | ||
| 2085 | ALUMINUM CAP FLASHING | SF | 10 | ||
| 2086 | METAL RIDGE VENT/CAP | LF | 1000 | ||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT | |||||
| 2087 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 50 | ||
| 2088 | ALUMINUM CAPPED CURB | LF | 10 | ||
| 2089 | GALVANIZED CAPPED CURB | LF | 50 | ||
| MISCELLANEOUS ITEMS | |||||
| 2090 | REMOVE AND REPLACE VENTILATOR, ROOFTOP | EA | 1 | ||
| 2091 | REMOVE AND REPLACE VENTILATOR, RIDGE | LF | 60 | ||
| 2092 | REMOVE AND REPLACE VENTILATOR, GABLE | EA | 1 | ||
| 2093 | REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHED | EA | 1 | ||
| 2094 | REMOVE AND REPLACE ROOF SCUTTLE | EA | 1 | ||
| DIV 7 - GUTTERS AND DOWNSPOUTS | |||||
| 2095 | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 300 | ||
| FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC. | |||||
| 2096 | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 50 | ||
| 2097 | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 200 | ||
| 2098 | ALUMINUM, 4" X 5" | LF | 10 | ||
| 2099 | ALUMINUM, 5" X 7" | LF | 10 | ||
| 2100 | 16 OZ. COPPER, 4" X 5" | LF | 10 | ||
| 2101 | 16 OZ. COPPER, 5" X 7" | LF | 10 | ||
| FURNISH AND INSTALL NEW DOWNSPOUTS INCLUDES BRACKETS, ETC. | |||||
| 2102 | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 100 | ||
| 2103 | ALUMINUM, 3" X 4" | LF | 10 | ||
| 2104 | 16 OZ. COPPER, 3" X 4" | LF | 10 | ||
| 2105 | FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 5 | ||
| DIV 7 - MANUFACTURED ROOF FRAMING SYSTEM | |||||
| 2106 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, <=100 SQ | SQ | 50 | ||
| 2107 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, >100 SQ | SQ | 110 | ||
| DIV 7 - STANDING SEAM METAL ROOFING | |||||
| 2108 | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL <=100 SQ | SQ | 200 | ||
| 2109 | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQ | SQ | 200 | ||
| 2110 | FASCIA PANEL SYSTEM | SF | 1,000 | ||
| 2111 | NON-PERFORATED SOFFIT PANEL | SF | 700 | ||
| 2112 | PERFORATED SOFFIT PANEL | SF | 300 | ||
| DIV 7 - CAULKING AND SEALANTS | |||||
| 2113 | REMOVE EXISTING CAULKING / CLEAN JOINT | LF | 150 | ||
| 2114 | SILICONE CAULKING / SEALANT | LF | 150 | ||
| 2115 | CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1 OR APPROVED EQUAL) | LF | 50 | ||
| DIV 9 - PAINTING | |||||
| 2116 | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | |||
| 2117 | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 500 | ||
| DIV 15 - ROOF DRAINS | |||||
| 2118 | REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 10 | ||
| 2119 | REMOVE AND REPLACE EXISTING ROOF DRAIN INCLUDES NEW CAST IRON DRAIN AND DOME STRAINER. | EA | 10 | ||
| DIV 16 - LIGHTING PROTECTION | |||||
| 2120 | REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERS | LS | 3 | ||
| 2121 | REMOVE AND REINSTALL EXISTING CONDUCTOR | LF | 300 | ||
| 2122 | REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPS | EA | 100 | ||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTING PROTECTION SYSTEM | |||||
| 2123 | AIR TERMINALS, INCLUDES COPPER BASE | EA | 10 | ||
| 2124 | CONDUCTORS | LF | 100 | ||
| 2125 | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 1 | ||
| 2126 | CONNECTORS | EA | 1 | ||
| 2127 | GROUNDING RODS | EA | 1 | ||
| 2128 | SURGE PROTECTION | EA | 1 | ||
| 2129 | UL SITE INSPECTION | EA | 1 | ||
| MISCELLANEOUS ROOFING ITEMS | |||||
| 2130 | EXTEND PLUMBING VENTS | LF | 10 | ||
| 2131 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 20 | ||
| 2132 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR), BUR's | EA | 30 | ||
| 2133 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH NEW COLLAR TYPE FLASHING | EA | 10 | ||
| 2134 | REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 50 | ||
| 2135 | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKS | SQ | 10 | ||
| 2136 | FURNISH AND INSTALL ROSIN PAPER OVER WOOD ROOF DECKS | SQ | 1 | ||
| 2137 | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP) | EA | 1 | ||
| 2138 | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 50 | ||
| 2139 | ROLL COIL RIDGE VENT | LF | 300 | ||
| 2140 | 60MIL WATERPROOF UNDERLAYMENT | LF | 100 | ||
| 2141 | SPUD EXISTING ROOF TO INSULATION | SF | 100 | ||
| 2142 | TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA | EA | 5 | ||
| ENGINEERING / SUB-CONTRACTORS | |||||
| 2143 | ENGINEERING RATE STRUCTURAL | HR | 20 | ||
| 2144 | MECHANICAL SUBCONTRACTOR (SHEET METAL WORKER) | HR | 20 | ||
| 2145 | ELECTRICAL SUBCONTRACTOR (ELECTRICIAN) | HR | 20 | ||
| 2146 | LABOR RATE - MISCELLANEOUS WORK (SHEET METAL WORKER) | MH | 40 | ||
| SPECIAL CONDITIONS AND CIRCUMSTANCES | |||||
| 2147 | HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOB | EA | 2 | ||
| MODIFIERS | |||||
| 2148 | COEFFICIENT % TO BE MULTIPLIED TO TOTAL FOR URGENT DELIVERY ORDER (UDO) - TEMPORARY DRY-IN WORK ONLY | 35% |
TOTAL
OPTION YEAR 2 FA4417-10-R-0012, Attachment 1 Bid Schedule
&P of &N ATTACHMENT 1 &D
Option Yr 3
| OPT YR 3 | DESCRIPTION - SUPPLIES OR SERVICES AND PRICES/COSTS | Date: 30 Jun 2010 | |||
| LINE | UNIT PRICE SCHEDULE | Unit | EST. | ||
| ITEM | IDIQ REPAIR AND REPLACE ROOFS | QTY. | UNIT PRICE | TOTAL | |
| DIV 2 - SELECTIVE DEMOLITION | |||||
| 3001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF | BF | 100 | ||
| 3002 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BF | BF | 100 | ||
| 3003 | REMOVE AND REPLACE WOOD DECKING | BF | 10 | ||
| 3004 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING, 3/4" | SF | 200 | ||
| 3005 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, 0-20 BF | BF | 50 | ||
| 3006 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, >20 BF | BF | 50 | ||
| 3007 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | BF | 10 | ||
| DIV 2 - TEAR OFFS | |||||
| 3008 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC (DOES NOT INCLUDE INSULATION) | SQ | 400 | ||
| 3009 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3" | SQ | 400 | ||
| 3010 | REMOVE AND DISPOSE OF EXISTING SHINGLE ROOF SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | ||
| 3011 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | ||
| 3012 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 500 | ||
| DIV 5 - STEEL ROOF DECK | |||||
| 3013 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 50 | ||
| DIV 7 - INSULATION | |||||
| 3014 | POLYISOCYANURATE BOARD INSULATION - 1" THICK, MIN. R- 6.5 | SQ | 100 | ||
| 3015 | POLYISOCYANURATE BOARD INSULATION - 2" THICK, MIN R-13.0 | SQ | 100 | ||
| 3016 | POLYISOCYANURATE BOARD INSULATION - 3" THICK, MIN R-19.0 | SQ | 300 | ||
| 3017 | PERLITE BOARD INSULATION, 3/4" THICK, R2.08, <=100 SQ | SQ | 200 | ||
| 3018 | PERLITE BOARD INSULATION, 3/4" THICK, R2.08, >100 SQ | SQ | 200 | ||
| 3019 | METAL BUILDING ROOF INSULATION R-30 | SF | 400 | ||
| 3020 | FIBER CANTS | LF | 250 | ||
| 3021 | WOOD CANTS | LF | 50 | ||
| 3022 | TAPERED FILL INSULATION BOARD | BF | 2,000 | ||
| 3023 | TAPERED 1/4" PER FOOT FOR DRAINAGE | BF | 3,000 | ||
| DIV 7 - SHINGLE ROOFING SYSTEMS | |||||
| 3024 | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 40 | ||
| 3025 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL FIBERGLASS SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 60 | ||
| 3026 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 50 | ||
| 3027 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 30 | ||
| 3028 | FELT, GLASS FIBER, 15 POUND ORGANIC | SQ | 10 | ||
| 3029 | FELT, GLASS FIBER, 30 POUND ORGANIC | SQ | 30 | ||
| DIV 7 - BITUMINOUS ROOFING (BURS) | |||||
| 3030 | 4-PLY BURS USING ASPHALT | SQ | 50 | ||
| 3031 | 4-PLY BURS USING COAL TAR | SQ | 50 | ||
| 3032 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 100 | ||
| 3033 | REMOVE AND REPLACE PITCH PAN | EA | 10 | ||
| DIV 7 - PARTIAL BURS REPAIRS | |||||
| 3034 | REPAIR BLISTERS | SF | 100 | ||
| 3035 | REPAIR SPLITS | SF | 50 | ||
| 3036 | REPAIR RIDGES | SF | 50 | ||
| 3037 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 200 | ||
| DIV 7 - PREPARED ROLL ROOFING | |||||
| 3038 | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS PREPARED ROLL ROOFING INCLUDING UNDERLAYMENT | SQ | 100 | ||
| 3039 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 10 | ||
| DIV 7 - POLYVINYL-CHLORIDE ROOFING (PVC) | |||||
| 3040 | FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 48 MILS | SQ | 1 | ||
| 3041 | FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 72 MILS | SQ | 1 | ||
| 3042 | FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 60 MILS | SQ | 1 | ||
| 3043 | FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 72 MILS | SQ | 1 | ||
| 3044 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 10 | ||
| 3045 | PVC LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUT | LF | 10 | ||
| 3046 | PVC VENT BOOTS | EA | 1 | ||
| 3047 | PVC UNIVERSAL CORNERS | EA | 1 | ||
| 3048 | PATCH AND REPAIR PVC SYSTEM | SF | 10 | ||
| DIV 7 - THERMOPLASTIC POLYOLEFIN ROOFING (TPO) | |||||
| 3049 | FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 45 MILS | SQ | 1 | ||
| 3050 | FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 60 MILS | SQ | 1 | ||
| 3051 | FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 45 MILS | SQ | 1 | ||
| 3052 | FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 60 MILS | SQ | 1 | ||
| 3053 | TPO LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 10 | ||
| 3054 | TPO LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUT | LF | 10 | ||
| 3055 | TPO VENT BOOTS | EA | 1 | ||
| 3056 | TPO UNIVERSAL CORNERS | EA | 1 | ||
| 3057 | PATCH AND REPAIR TPO SYSTEM | SF | 10 | ||
| DIV 7 - FLUID APPLIED ROOF COATING SYSTEM, METAL ROOFS | |||||
| 3058 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 1 | ||
| DIV 7 - TRAFFIC BEARING ROOF DECK SURFACING | |||||
| 3059 | TRAFFIC BEARING ROOF DECK SURFACING SYSTEM | SQ | 20 | ||
| DIV 7 - SHEET METAL WORK, GENERAL | |||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | |||||
| 3060 | GALVANIZED METAL, 4"-5" | LF | 150 | ||
| 3061 | GALVANIZED METAL, 6"-7" | LF | 150 | ||
| 3062 | ALUMINUM, 4"-5" | LF | 10 | ||
| 3063 | ALUMINUM, 6"-7" | LF | 10 | ||
| 3064 | COPPER, 4"-5" | LF | 10 | ||
| 3065 | COPPER, 6"-7" | LF | 10 | ||
| 3066 | 2-PIECE GALVANIZED METAL, 7"-10" | LF | 20 | ||
| 3067 | 2-PIECE GALVANIZED METAL, 10"-12" | LF | 20 | ||
| 3068 | 2-PIECE ALUMINUM, 7"-10" | LF | 10 | ||
| 3069 | 2-PIECE ALUMINUM, 10"-12" | LF | 10 | ||
| 3070 | 2-PIECE COPPER, 7"-10" | LF | 10 | ||
| 3071 | 2-PIECE COPPER, 10"-12" | LF | 10 | ||
| FURNISH AND INSTALL: | |||||
| 3072 | GALVANIZED METAL DRIP EDGE | LF | 100 | ||
| 3073 | GALVANIZED METAL COUNTERFLASHING | SF | 200 | ||
| 3074 | GALVANIZED METAL VALLEY FLASHING | SF | 100 | ||
| 3075 | GALVANIZED METAL STEP FLASHING | SF | 20 | ||
| 3076 | GALVANIZED METAL BASE FLASHING | SF | 20 | ||
| 3077 | GALVANIZED METAL FLASHING, FLAT SHEET | SF | 200 | ||
| 3078 | GALVANIZED METAL CAP FLASHING | SF | 100 | ||
| 3079 | ALUMINUM DRIP EDGE | LF | 10 | ||
| 3080 | ALUMINUM COUNTERFLASHING | SF | 10 | ||
| 3081 | ALUMINUM VALLEY FLASHING | SF | 10 | ||
| 3082 | ALUMINUM STEP FLASHING | SF | 10 | ||
| 3083 | ALUMINUM BASE FLASHING | SF | 10 | ||
| 3084 | ALUMINUM FLASHING, FLAT SHEET | SF | 10 | ||
| 3085 | ALUMINUM CAP FLASHING | SF | 10 | ||
| 3086 | METAL RIDGE VENT/CAP | LF | 1000 | ||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT | |||||
| 3087 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 50 | ||
| 3088 | ALUMINUM CAPPED CURB | LF | 10 | ||
| 3089 | GALVANIZED CAPPED CURB | LF | 50 | ||
| MISCELLANEOUS ITEMS | |||||
| 3090 | REMOVE AND REPLACE VENTILATOR, ROOFTOP | EA | 1 | ||
| 3091 | REMOVE AND REPLACE VENTILATOR, RIDGE | LF | 60 | ||
| 3092 | REMOVE AND REPLACE VENTILATOR, GABLE | EA | 1 | ||
| 3093 | REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHED | EA | 1 | ||
| 3094 | REMOVE AND REPLACE ROOF SCUTTLE | EA | 1 | ||
| DIV 7 - GUTTERS AND DOWNSPOUTS | |||||
| 3095 | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 300 | ||
| FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC. | |||||
| 3096 | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 50 | ||
| 3097 | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 200 | ||
| 3098 | ALUMINUM, 4" X 5" | LF | 10 | ||
| 3099 | ALUMINUM, 5" X 7" | LF | 10 | ||
| 3100 | 16 OZ. COPPER, 4" X 5" | LF | 10 | ||
| 3101 | 16 OZ. COPPER, 5" X 7" | LF | 10 | ||
| FURNISH AND INSTALL NEW DOWNSPOUTS INCLUDES BRACKETS, ETC. | |||||
| 3102 | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 100 | ||
| 3103 | ALUMINUM, 3" X 4" | LF | 10 | ||
| 3104 | 16 OZ. COPPER, 3" X 4" | LF | 10 | ||
| 3105 | FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 5 | ||
| DIV 7 - MANUFACTURED ROOF FRAMING SYSTEM | |||||
| 3106 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, <=100 SQ | SQ | 50 | ||
| 3107 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, >100 SQ | SQ | 110 | ||
| DIV 7 - STANDING SEAM METAL ROOFING | |||||
| 3108 | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL <=100 SQ | SQ | 200 | ||
| 3109 | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQ | SQ | 200 | ||
| 3110 | FASCIA PANEL SYSTEM | SF | 1,000 | ||
| 3111 | NON-PERFORATED SOFFIT PANEL | SF | 700 | ||
| 3112 | PERFORATED SOFFIT PANEL | SF | 300 | ||
| DIV 7 - CAULKING AND SEALANTS | |||||
| 3113 | REMOVE EXISTING CAULKING / CLEAN JOINT | LF | 150 | ||
| 3114 | SILICONE CAULKING / SEALANT | LF | 150 | ||
| 3115 | CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1 OR APPROVED EQUAL) | LF | 50 | ||
| DIV 9 - PAINTING | |||||
| 3116 | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | |||
| 3117 | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 500 | ||
| DIV 15 - ROOF DRAINS | |||||
| 3118 | REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 10 | ||
| 3119 | REMOVE AND REPLACE EXISTING ROOF DRAIN INCLUDES NEW CAST IRON DRAIN AND DOME STRAINER. | EA | 10 | ||
| DIV 16 - LIGHTING PROTECTION | |||||
| 3120 | REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERS | LS | 3 | ||
| 3121 | REMOVE AND REINSTALL EXISTING CONDUCTOR | LF | 300 | ||
| 3122 | REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPS | EA | 100 | ||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTING PROTECTION SYSTEM | |||||
| 3123 | AIR TERMINALS, INCLUDES COPPER BASE | EA | 10 | ||
| 3124 | CONDUCTORS | LF | 100 | ||
| 3125 | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 1 | ||
| 3126 | CONNECTORS | EA | 1 | ||
| 3127 | GROUNDING RODS | EA | 1 | ||
| 3128 | SURGE PROTECTION | EA | 1 | ||
| 3129 | UL SITE INSPECTION | EA | 1 | ||
| MISCELLANEOUS ROOFING ITEMS | |||||
| 3130 | EXTEND PLUMBING VENTS | LF | 10 | ||
| 3131 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 20 | ||
| 3132 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR), BUR's | EA | 30 | ||
| 3133 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH NEW COLLAR TYPE FLASHING | EA | 10 | ||
| 3134 | REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 50 | ||
| 3135 | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKS | SQ | 10 | ||
| 3136 | FURNISH AND INSTALL ROSIN PAPER OVER WOOD ROOF DECKS | SQ | 1 | ||
| 3137 | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP) | EA | 1 | ||
| 3138 | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 50 | ||
| 3139 | ROLL COIL RIDGE VENT | LF | 300 | ||
| 3140 | 60MIL WATERPROOF UNDERLAYMENT | LF | 100 | ||
| 3141 | SPUD EXISTING ROOF TO INSULATION | SF | 100 | ||
| 3142 | TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA | EA | 5 | ||
| ENGINEERING / SUB-CONTRACTORS | |||||
| 3143 | ENGINEERING RATE STRUCTURAL | HR | 20 | ||
| 3144 | MECHANICAL SUBCONTRACTOR (SHEET METAL WORKER) | HR | 20 | ||
| 3145 | ELECTRICAL SUBCONTRACTOR (ELECTRICIAN) | HR | 20 | ||
| 3146 | LABOR RATE - MISCELLANEOUS WORK (SHEET METAL WORKER) | MH | 40 | ||
| SPECIAL CONDITIONS AND CIRCUMSTANCES | |||||
| 3147 | HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOB | EA | 2 | ||
| MODIFIERS | |||||
| 3148 | COEFFICIENT % TO BE MULTIPLIED TO TOTAL FOR URGENT DELIVERY ORDER (UDO) - TEMPORARY DRY-IN WORK ONLY | 35% |
TOTAL
OPTION YEAR 3 FA4417-10-R-0012, Attachment 1 Bid Schedule
&P of &N ATTACHMENT 1 &D
Option Yr 4
| OPT YR 4 | DESCRIPTION - SUPPLIES OR SERVICES AND PRICES/COSTS | Date: 30 Jun 2010 | |||
| LINE | UNIT PRICE SCHEDULE | Unit | EST. | ||
| ITEM | IDIQ REPAIR AND REPLACE ROOFS | QTY. | UNIT PRICE | TOTAL | |
| DIV 2 - SELECTIVE DEMOLITION | |||||
| 4001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF | BF | 100 | ||
| 4002 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BF | BF | 100 | ||
| 4003 | REMOVE AND REPLACE WOOD DECKING | BF | 10 | ||
| 4004 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING, 3/4" | SF | 200 | ||
| 4005 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, 0-20 BF | BF | 50 | ||
| 4006 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THICK, >20 BF | BF | 50 | ||
| 4007 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | BF | 10 | ||
| DIV 2 - TEAR OFFS | |||||
| 4008 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC (DOES NOT INCLUDE INSULATION) | SQ | 400 | ||
| 4009 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3" | SQ | 400 | ||
| 4010 | REMOVE AND DISPOSE OF EXISTING SHINGLE ROOF SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | ||
| 4011 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 100 | ||
| 4012 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 500 | ||
| DIV 5 - STEEL ROOF DECK | |||||
| 4013 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 50 | ||
| DIV 7 - INSULATION | |||||
| 4014 | POLYISOCYANURATE BOARD INSULATION - 1" THICK, MIN. R- 6.5 | SQ | 100 | ||
| 4015 | POLYISOCYANURATE BOARD INSULATION - 2" THICK, MIN R-13.0 | SQ | 100 | ||
| 4016 | POLYISOCYANURATE BOARD INSULATION - 3" THICK, MIN R-19.0 | SQ | 300 | ||
| 4017 | PERLITE BOARD INSULATION, 3/4" THICK, R2.08, <=100 SQ | SQ | 200 | ||
| 4018 | PERLITE BOARD INSULATION, 3/4" THICK, R2.08, >100 SQ | SQ | 200 | ||
| 4019 | METAL BUILDING ROOF INSULATION R-30 | SF | 400 | ||
| 4020 | FIBER CANTS | LF | 250 | ||
| 4021 | WOOD CANTS | LF | 50 | ||
| 4022 | TAPERED FILL INSULATION BOARD | BF | 2,000 | ||
| 4023 | TAPERED 1/4" PER FOOT FOR DRAINAGE | BF | 3,000 | ||
| DIV 7 - SHINGLE ROOFING SYSTEMS | |||||
| 4024 | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 40 | ||
| 4025 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL FIBERGLASS SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 60 | ||
| 4026 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 50 | ||
| 4027 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 30 | ||
| 4028 | FELT, GLASS FIBER, 15 POUND ORGANIC | SQ | 10 | ||
| 4029 | FELT, GLASS FIBER, 30 POUND ORGANIC | SQ | 30 | ||
| DIV 7 - BITUMINOUS ROOFING (BURS) | |||||
| 4030 | 4-PLY BURS USING ASPHALT | SQ | 50 | ||
| 4031 | 4-PLY BURS USING COAL TAR | SQ | 50 | ||
| 4032 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 100 | ||
| 4033 | REMOVE AND REPLACE PITCH PAN | EA | 10 | ||
| DIV 7 - PARTIAL BURS REPAIRS | |||||
| 4034 | REPAIR BLISTERS | SF | 100 | ||
| 4035 | REPAIR SPLITS | SF | 50 | ||
| 4036 | REPAIR RIDGES | SF | 50 | ||
| 4037 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 200 | ||
| DIV 7 - PREPARED ROLL ROOFING | |||||
| 4038 | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS PREPARED ROLL ROOFING INCLUDING UNDERLAYMENT | SQ | 100 | ||
| 4039 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 10 | ||
| DIV 7 - POLYVINYL-CHLORIDE ROOFING (PVC) | |||||
| 4040 | FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 48 MILS | SQ | 1 | ||
| 4041 | FURNISH AND INSTALL FULLY ADHERED PVC SYSTEM - 72 MILS | SQ | 1 | ||
| 4042 | FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 60 MILS | SQ | 1 | ||
| 4043 | FURNISH AND INSTALL MECHANICALLY FASTENED PVC SYSTEM - 72 MILS | SQ | 1 | ||
| 4044 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 10 | ||
| 4045 | PVC LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUT | LF | 10 | ||
| 4046 | PVC VENT BOOTS | EA | 1 | ||
| 4047 | PVC UNIVERSAL CORNERS | EA | 1 | ||
| 4048 | PATCH AND REPAIR PVC SYSTEM | SF | 10 | ||
| DIV 7 - THERMOPLASTIC POLYOLEFIN ROOFING (TPO) | |||||
| 4049 | FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 45 MILS | SQ | 1 | ||
| 4050 | FURNISH AND INSTALL FULLY ADHERED TPO SYSTEM - 60 MILS | SQ | 1 | ||
| 4051 | FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 45 MILS | SQ | 1 | ||
| 4052 | FURNISH AND INSTALL MECHANICALLY FASTENED TPO SYSTEM - 60 MILS | SQ | 1 | ||
| 4053 | TPO LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 10 | ||
| 4054 | TPO LAMINATED METAL FLASHING UP TO 18.01" TO 36" STRETCH OUT | LF | 10 | ||
| 4055 | TPO VENT BOOTS | EA | 1 | ||
| 4056 | TPO UNIVERSAL CORNERS | EA | 1 | ||
| 4057 | PATCH AND REPAIR TPO SYSTEM | SF | 10 | ||
| DIV 7 - FLUID APPLIED ROOF COATING SYSTEM, METAL ROOFS | |||||
| 4058 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 1 | ||
| DIV 7 - TRAFFIC BEARING ROOF DECK SURFACING | |||||
| 4059 | TRAFFIC BEARING ROOF DECK SURFACING SYSTEM | SQ | 20 | ||
| DIV 7 - SHEET METAL WORK, GENERAL | |||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | |||||
| 4060 | GALVANIZED METAL, 4"-5" | LF | 150 | ||
| 4061 | GALVANIZED METAL, 6"-7" | LF | 150 | ||
| 4062 | ALUMINUM, 4"-5" | LF | 10 | ||
| 4063 | ALUMINUM, 6"-7" | LF | 10 | ||
| 4064 | COPPER, 4"-5" | LF | 10 | ||
| 4065 | COPPER, 6"-7" | LF | 10 | ||
| 4066 | 2-PIECE GALVANIZED METAL, 7"-10" | LF | 20 | ||
| 4067 | 2-PIECE GALVANIZED METAL, 10"-12" | LF | 20 | ||
| 4068 | 2-PIECE ALUMINUM, 7"-10" | LF | 10 | ||
| 4069 | 2-PIECE ALUMINUM, 10"-12" | LF | 10 | ||
| 4070 | 2-PIECE COPPER, 7"-10" | LF | 10 | ||
| 4071 | 2-PIECE COPPER, 10"-12" | LF | 10 | ||
| FURNISH AND INSTALL: | |||||
| 4072 | GALVANIZED METAL DRIP EDGE | LF | 100 | ||
| 4073 | GALVANIZED METAL COUNTERFLASHING | SF | 200 | ||
| 4074 | GALVANIZED METAL VALLEY FLASHING | SF | 100 | ||
| 4075 | GALVANIZED METAL STEP FLASHING | SF | 20 | ||
| 4076 | GALVANIZED METAL BASE FLASHING | SF | 20 | ||
| 4077 | GALVANIZED METAL FLASHING, FLAT SHEET | SF | 200 | ||
| 4078 | GALVANIZED METAL CAP FLASHING | SF | 100 | ||
| 4079 | ALUMINUM DRIP EDGE | LF | 10 | ||
| 4080 | ALUMINUM COUNTERFLASHING | SF | 10 | ||
| 4081 | ALUMINUM VALLEY FLASHING | SF | 10 | ||
| 4082 | ALUMINUM STEP FLASHING | SF | 10 | ||
| 4083 | ALUMINUM BASE FLASHING | SF | 10 | ||
| 4084 | ALUMINUM FLASHING, FLAT SHEET | SF | 10 | ||
| 4085 | ALUMINUM CAP FLASHING | SF | 10 | ||
| 4086 | METAL RIDGE VENT/CAP | LF | 1000 | ||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT | |||||
| 4087 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 50 | ||
| 4088 | ALUMINUM CAPPED CURB | LF | 10 | ||
| 4089 | GALVANIZED CAPPED CURB | LF | 50 | ||
| MISCELLANEOUS ITEMS | |||||
| 4090 | REMOVE AND REPLACE VENTILATOR, ROOFTOP | EA | 1 | ||
| 4091 | REMOVE AND REPLACE VENTILATOR, RIDGE | LF | 60 | ||
| 4092 | REMOVE AND REPLACE VENTILATOR, GABLE | EA | 1 | ||
| 4093 | REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHED | EA | 1 | ||
| 4094 | REMOVE AND REPLACE ROOF SCUTTLE | EA | 1 | ||
| DIV 7 - GUTTERS AND DOWNSPOUTS | |||||
| 4095 | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 300 | ||
| FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC. | |||||
| 4096 | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 50 | ||
| 4097 | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 200 | ||
| 4098 | ALUMINUM, 4" X 5" | LF | 10 | ||
| 4099 | ALUMINUM, 5" X 7" | LF | 10 | ||
| 4100 | 16 OZ. COPPER, 4" X 5" | LF | 10 | ||
| 4101 | 16 OZ. COPPER, 5" X 7" | LF | 10 | ||
| FURNISH AND INSTALL NEW DOWNSPOUTS INCLUDES BRACKETS, ETC. | |||||
| 4102 | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 100 | ||
| 4103 | ALUMINUM, 3" X 4" | LF | 10 | ||
| 4104 | 16 OZ. COPPER, 3" X 4" | LF | 10 | ||
| 4105 | FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 5 | ||
| DIV 7 - MANUFACTURED ROOF FRAMING SYSTEM | |||||
| 4106 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, <=100 SQ | SQ | 50 | ||
| 4107 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE, >100 SQ | SQ | 110 | ||
| DIV 7 - STANDING SEAM METAL ROOFING | |||||
| 4108 | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL <=100 SQ | SQ | 200 | ||
| 4109 | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQ | SQ | 200 | ||
| 4110 | FASCIA PANEL SYSTEM | SF | 1,000 | ||
| 4111 | NON-PERFORATED SOFFIT PANEL | SF | 700 | ||
| 4112 | PERFORATED SOFFIT PANEL | SF | 300 | ||
| DIV 7 - CAULKING AND SEALANTS | |||||
| 4113 | REMOVE EXISTING CAULKING / CLEAN JOINT | LF | 150 | ||
| 4114 | SILICONE CAULKING / SEALANT | LF | 150 | ||
| 4115 | CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1 OR APPROVED EQUAL) | LF | 50 | ||
| DIV 9 - PAINTING | |||||
| 4116 | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | |||
| 4117 | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 500 | ||
| DIV 15 - ROOF DRAINS | |||||
| 4118 | REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 10 | ||
| 4119 | REMOVE AND REPLACE EXISTING ROOF DRAIN INCLUDES NEW CAST IRON DRAIN AND DOME STRAINER. | EA | 10 | ||
| DIV 16 - LIGHTING PROTECTION | |||||
| 4120 | REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERS | LS | 3 | ||
| 4121 | REMOVE AND REINSTALL EXISTING CONDUCTOR | LF | 300 | ||
| 4122 | REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPS | EA | 100 | ||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTING PROTECTION SYSTEM | |||||
| 4123 | AIR TERMINALS, INCLUDES COPPER BASE | EA | 10 | ||
| 4124 | CONDUCTORS | LF | 100 | ||
| 4125 | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 1 | ||
| 4126 | CONNECTORS | EA | 1 | ||
| 4127 | GROUNDING RODS | EA | 1 | ||
| 4128 | SURGE PROTECTION | EA | 1 | ||
| 4129 | UL SITE INSPECTION | EA | 1 | ||
| MISCELLANEOUS ROOFING ITEMS | |||||
| 4130 | EXTEND PLUMBING VENTS | LF | 10 | ||
| 4131 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 20 | ||
| 4132 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR), BUR's | EA | 30 | ||
| 4133 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH NEW COLLAR TYPE FLASHING | EA | 10 | ||
| 4134 | REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 50 | ||
| 4135 | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKS | SQ | 10 | ||
| 4136 | FURNISH AND INSTALL ROSIN PAPER OVER WOOD ROOF DECKS | SQ | 1 | ||
| 4137 | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP) | EA | 1 | ||
| 4138 | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 50 | ||
| 4139 | ROLL COIL RIDGE VENT | LF | 300 | ||
| 4140 | 60MIL WATERPROOF UNDERLAYMENT | LF | 100 | ||
| 4141 | SPUD EXISTING ROOF TO INSULATION | SF | 100 | ||
| 4142 | TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA | EA | 5 | ||
| ENGINEERING / SUB-CONTRACTORS | |||||
| 4143 | ENGINEERING RATE STRUCTURAL | HR | 20 | ||
| 4144 | MECHANICAL SUBCONTRACTOR (SHEET METAL WORKER) | HR | 20 | ||
| 4145 | ELECTRICAL SUBCONTRACTOR (ELECTRICIAN) | HR | 20 | ||
| 4146 | LABOR RATE - MISCELLANEOUS WORK (SHEET METAL WORKER) | MH | 40 | ||
| SPECIAL CONDITIONS AND CIRCUMSTANCES | |||||
| 4147 | HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOB | EA | 2 | ||
| MODIFIERS | |||||
| 4148 | COEFFICIENT % TO BE MULTIPLIED TO TOTAL FOR URGENT DELIVERY ORDER (UDO) - TEMPORARY DRY-IN WORK ONLY | 35% |
| TOTAL |
| TOTAL INCLUDING OPTION YEAR 1 THRU 4 |
OPTION YEAR 4 FA4417-10-R-0012, Attachment 1 Bid Schedule
&P of &N ATTACHMENT 1 &D