Attachment 7 -Roof IDC Schedule of Material Submittals.xls
XLS spreadsheet 26 KB Posted
- Attached to
- Roofing IDC Federal contract opportunity
- Solicitation number
- FA4416-08-R-
About this file
Schedule of Material Submittals
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA4416-08-R-0008-P0002.doc | DOC document | |
| Attachment 4a - Updated WD No MD080057 Construction type Building Prince George's County.doc | DOC document | |
| FA4416-08-R-0008-P0001.doc | DOC document | |
| Attachment 2 - Pricing Schedule B.xls | XLS spreadsheet | |
| Attachment 5 - WD No MD080021 Construction Type Building Anne Arundel County.doc | DOC document | |
| FA4416-08-R-0008.doc | DOC document | |
| Attachment 2 - Pricing Schedule B.xls | XLS spreadsheet | |
| Attachment 6 - Visitor Information.doc | DOC document | |
| Attachment 3 - Past Performance Questionnaire.doc | DOC document | |
| Attachment 4 - WD No MD080057 Construction type Building Prince George's County.doc | DOC document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AF FORM 66 S
| SCHEDULE OF MATERIAL SUBMITTALS | PROJECT NUMBER | PROJECT TITLE | SOLICITATION/ CONTRACT NUMBER | |||||||||||||||||||
| AJXF 08-1552 | ROOF IDC | |||||||||||||||||||||
| TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY CONTRACT ADMINISTRATOR | |||||||||||||||||||||
| NUMBER OF COPIES REQUIRED | DATE RECEIVED IN CONTRACTING | DATE TO CIVIL ENGINEERING | RETURN SUSPENSE DATE | SUBMITTAL NUMBER | CONTRACTOR RESUBMITTAL | FINAL APPROVAL | ||||||||||||||||
| LINE NUMBER | ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL | DATA - SD-01 | MANUFACTURER"S CATALOG DATA-SD-02 | MANUFACTURER'S STANDARD COLOR CHARTS - SD-03 | INSTRUCTIONS - SD-06 | SCHEDULES - SD-07 | STATEMENTS - SD-8 | TEST REPORTS - SD-10 | FIELD TEST REPORTS - SD-12 | SAMPLES - SD-14 | COLOR SELECTION SAMPLES - SD-15 | SAFETY PLAN SD-60 | REQUIRED SUBMISSION DATE | DATE CONTRACTOR NOTIFIED | REMARKS | |||||||
| APPROVED | DIS-APPROVED | |||||||||||||||||||||
| Special Conditions, 01012 | ||||||||||||||||||||||
| 1 | Health and Safety Plan, Section 1.3a | 4 | ||||||||||||||||||||
| Strip Shingle Roofing Repair/Replacement, 07300 | ||||||||||||||||||||||
| 2 | Asphalt Shingles (Section 2.2.2.1a & 2.2.2.2a/b) | 4 | 4 | 4 | 3 | |||||||||||||||||
| 3 | Asphalt Saturated Felt (Section 2.2.2.1.b) | 3 | ||||||||||||||||||||
| 4 | Shingle Fasteners (Section 2.1.2.1.c) | 3 | ||||||||||||||||||||
| 5 | Asphalt Roof Cement (Section 2.1.2.1.d) | 1 qt. | ||||||||||||||||||||
| 6 | Shingle Roofing System Manufacturer's Certification (Section 1.5.1) | 4 | ||||||||||||||||||||
| 7 | Contractor Workmanship Warranty (Section 1.5.2) | 4 | ||||||||||||||||||||
| 8 | Strip Shingle Roofing System 20 Year Material Warranty (Section 1.5.3) | 4 | ||||||||||||||||||||
| Standing Seam Metal Roofing, 07400 | ||||||||||||||||||||||
| 9 | Roofing Panels (Sections 1.4.2, 1.4.4, 1.4.5, 1.4.7) | 4 | 4 | 2 | 2 | |||||||||||||||||
| 10 | Attachment Clips (Section 1.4.2 & 1.4.7) | 4 | 4 | |||||||||||||||||||
| 11 | Closures (Section 1.4.2 & 1.4.7) | 4 | 4 | |||||||||||||||||||
| 12 | Accessories (Section 1.4.2, 1.4.4, 1.4.7) | 4 | 4 | 2 | ||||||||||||||||||
| 13 | Underlayment (Section 1.4.2 & 1.4.7) | 4 | 4 | |||||||||||||||||||
| 14 | Sealants and Sealant Tape (Sections 1.4.2, 1.4.3, 1.4.4, 1.4.7) | 4 | 4 | 4 | 2 | |||||||||||||||||
| 15 | Standing Seam Metal Roofing Manufacturer's Certification (Section 1.4.6) | 4 | ||||||||||||||||||||
| 16 | Contractor Workmanship Warranty (Section 1.4.6) | 4 | ||||||||||||||||||||
| 17 | Strip Shingle Roofing System 20 Year Material Warranty (Section 1.4.6) | 4 | ||||||||||||||||||||
| Built-Up Roofing Repair/Replacement Specifications, 07500 | ||||||||||||||||||||||
| 18 | Asphalt (Section 2.1.2.1 & 2.1.2.2) | 4 | 4 | |||||||||||||||||||
| 19 | Felts, including flashing felts and base flashing (Section 2.1.2.1 & 2.1.2.2) | 4 | 4 | |||||||||||||||||||
| 20 | Fasteners (Section 2.1.2.1) | 4 | ||||||||||||||||||||
| 21 | Primer (Section 2.1.2.1 & 2.1.2.2) | 4 | 4 | |||||||||||||||||||
| 22 | Asphalt Roof Cement (Section 2.1.2.1 & 2.1.2.2) | 4 | 4 | |||||||||||||||||||
| 23 | Walkway Material (Section 2.1.2.2) | 4 | ||||||||||||||||||||
| 24 | Built-Up Roofing Manufacturer's Certification (Section 1.5.1) | 4 | ||||||||||||||||||||
| 25 | Contractor Workmanship Warranty (Section 1.5.2) | 4 | ||||||||||||||||||||
| 26 | Built-Up Roof System 20 Year Material Warranty (Section 1.5.3) | 4 | ||||||||||||||||||||
| Modified Bitumen Sheet Roofing, 07535 | ||||||||||||||||||||||
| 27 | Modified Bitumen Sheet (Sections 1.2.1 & 1.2.2) | 4 | 4 | |||||||||||||||||||
| 28 | Asphalt (Sections 1.2.1 & 1.2.2) | 4 | 4 | |||||||||||||||||||
| 29 | Felts (Section 1.2.1 & 1.2.2) | 4 | 4 | |||||||||||||||||||
| 30 | Primer (Sections 1.2.1 & 1.2.2) | 4 | 4 | |||||||||||||||||||
| 31 | Asphalt Roof Cement (Section 1.2.1 & 1.2.2) | 4 | 4 | |||||||||||||||||||
| 32 | Fasteners (Section 1.2.1 & 1.2.2) | 4 | 4 | |||||||||||||||||||
| 33 | Coating (Section 1.2.1 & 1.2.2) | 4 | 4 | |||||||||||||||||||
| 34 | Torches (Section 1.2.2) | 4 | ||||||||||||||||||||
| 35 | Flashing (Section 1.2.2) | 4 | ||||||||||||||||||||
| 36 | Cold Weather Installation (Section 1.2.2) | 4 | ||||||||||||||||||||
| 37 | Modified Bitumen Sheet Roofing Manufacturer's Certification (Submittal #1) | 4 | ||||||||||||||||||||
| 38 | Contractor Workmanship Warranty (Submittal #2) | 4 | ||||||||||||||||||||
| 39 | Modified Bitumen Sheet Roofing 20 Year Material Warranty (Submittal #3) | 4 |
&C&12Attachment 7 - Schedule of Material Submittals
&LAF FORM 66