CASS_Attachment_5_PLC_Hardware.pdf

PDF 260 KB Posted

Attached to
Centralized Aircraft Support System (CASS) Upgrade
Solicitation number
FA3016-17-R-0025
Issued by

About this file

Q&A CASS Attachment 5, PLC Hardware

View the file

Other files

File Type Posted
FA3016-17-R-0025-0004_Revise_Section_L_signed.pdf PDF
CASS_Attachment_7_Pneumatics_Hardware.pdf PDF
CASS_Attachment_2__Schematics.pdf PDF
CASS_Attachment_3_Station_Hardware.pdf PDF
CASS_Attachment_4_Touch_Screens_Hardware.pdf PDF
FA3016-17-R-0025_CASS_System_Upgrades_2nd_Site_Visit_Q&A.docx DOCX document
CASS_Attachment_8_3052_JBA_400Hz_SingleJacket_Sept_2016.pdf PDF
CASS_Attachment_1_Description,_Operation_and_Maintenance.pdf PDF
CASS_Attachment_6_PLC_Program_Data.pdf PDF
2_-_SOW_TYMX150072_CASS_T-38_Row_2-7_Rev_22Jun2017.docx DOCX document
FA3016-17-R-0025_New_SOW_attch_D.pdf PDF
Appendix_D_-_CASS_Existing_Drawings,_2001.zip ZIP file
Questions_and_Answers__2.docx DOCX document
Questions_and_Answers__1.xlsx XLSX spreadsheet
Atch_1_Statement_of_Work.pdf PDF
Atch_2_Wage_Determination_02_June_17.pdf PDF
FA3016-17-R-0025-P00001_Suspend_Solicitation.pdf PDF
Atch_11_Project_Location.pdf PDF
32 13 11 - Concrete Pavement for Airfield and Other Heavy-Duty Pavements.docx DOCX document
Atch_4__Financial_Information_Questionnaire.docx DOCX document
Atch_7_AETC_Form_47.pdf PDF
01 10 00 —
32 01 19 61 - Resealing of Joints in Rigid Pavement.docx DOCX document
09 90 00 PAINTS AND COATINGS.doc DOC document
01 45 01 - Quality Control.doc DOC document
03 20 01 00 10 - Concrete Reinforcement.doc.docx DOCX document
RFP_FA3016-17-R-0025.docx DOCX document
Atch_9_Progress_Schedule.xlsx XLSX spreadsheet
Atch_3_Base_Access_Request.pdf PDF
03 01 30.71 - Concrete Rehabilitation.doc DOC document
Section_01_35_35__Environmental_Protection Mar 15.pdf PDF
01 21 53 —
03 20 02 STEEL BARS AND WELDED WIRE FABRIC FOR CONCRETE REINFORCEMENT FOR CIVIL WORKS.doc DOC document
03 39 00 00 10 - Concrete Curing.docx DOCX document
Appendix_C_Computerized_Master_Control_CASS_System.pptx PPTX presentation
02 41 00 —
Atch_8_HAZMAT_Letter.pdf PDF
09 90 00.00 40 PAINTING AND COATING.doc DOC document
03 15 13.00 10 EXPANSION JOINT, CONTRACTION JOINT & WATER STOPS.doc DOC document
Atch_2_Wage_Determination.pdf PDF
02 83 00 —
Atch_6_Cost_Estimate_Breakdown.xls XLS spreadsheet
01 03 00 - Project Closeout.docx DOCX document
Appendix_B_CASS_Technical_Order.pdf PDF
Atch_10_Local_Information.pdf PDF
32 12 11 - Bituminous Surface Treatments.doc DOC document
32 01 19 - Field Molded Sealants for Sealing Joints in Rigid Pavements.doc DOC document
32 01 17.16 - Sealing of Cracks in Bituminous Pavements.doc DOC document
00 00 00 - Construction Contract Security Requirements.doc DOC document
03 15 00 00 10 - Concrete Accessories.docx DOCX document
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Wago:

Programmable Fieldbus Controller

& Hardware

Table of Contents

4. 750-841: Programmable Bus Coupler pg 3-4

5. 750-423: Module, 2-Channel Input pg 5

6. 750-513: Module, 2-Channel Output pg 6

7. 750-600: Module, End pg 7

24V 0V

01 02

0-

LINK

MS

NS

I/O

ETHERNET

C

D B

A

TxD/RxD

USR

ETHERNET TCP/IP

Programmable Fieldbus Controller; 10/100 Mbit/s; digital and analog signals

Fieldbus connection

RJ 45

Configuration and programming interface

Power jumper contacts

Status voltage supply -Power jumper contacts

-System Data contacts

Supply 24 V 0 V

Supply via power jumper contacts 24 V

0 V

750-841

This fieldbus controller allows the connection of the WAGO%SYSTEM as a slave to the ETHERNET.

The fieldbus controller is capable of supporting all I/O modules. The controller automatically configures itself, creating a local process image which may include analog, digital or specialty modules. Analog and specialty modules data is sent via words or bytes, digital data is packed into words or bytes.

This fieldbus controller is suitable for data rates of 10 Mbit /s and 100 Mbit /s. It is programmable according to IEC 61131-3 using 512 KB program memory, 128 KB data memory and 24 KB retentive memory. This 32-bit based CPU is capable of multitasking and has a battery backed real-time clock.

The controller offers many different application protocols which can be used for data acquisition or control (MODBUS, ETHERNET /IP) or for system managing and diagnostics (HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP and SMTP).

The WAGO ETHERNET controller has additional functionalities, which allow controlled access to the control and configuration data. Protection against unauthorized access is made possible with full TCP /IP functionality. When the security option is switched on, only predefined clients can communicate with the WAGO ETHERNET controller. The IP-filter is configured by means of web pages in the ETHERNET controller.

System DataItem Pack.-unit No. pcs

Programmable 100MBit ETHERNET fieldbus controller 750-841 1

Description

Max. no. of nodes limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 100 Ω cat. 5 Buscoupler connection RJ 45 Max. length of fieldbus segment 100 m between hub station and 750-841 max. length of network limited by ETHERNET specification

Baud rate 10 /100 Mbits /s Protocols MODBUS /TCP (UDP), ETHERNET /IP, HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP, SMTP Programming WAGO-I/O-PRO CAA

IEC 61131-3 IL, LD, FBD, ST, FC

Subject to design changes

NEW 2004

WAGO Kontakttechnik GmbH Postfach 2880 • D-32385 Minden Tel.: +49(0)5 71 /8 87-0 E-Mail: info@wago.com Hansastr. 27 • D-32423 Minden Fax.: +49(0)5 71 /8 87-169 www.wago.com17.09.2004

DC

DC

24 V

10 nF

24 V

10 nF

0 V

24 V /0 V

24 V

0 V

0 V

750-841

Subject to design changes

Max. no. of I/O modules 64 with bus extension 255 per node Digital signals max. 2040 (inputs and outputs) Analog signals max. 1020 (inputs and outputs) Config. possibility via PC Program memory 512 Kbytes Data memory 128 Kbytes Non-volatile memory 24 Kbytes (retentive) Voltage supply DC 24 V (-15 % ... +20 %) Input current max. 500 mA at 24 V Efficiency of the power supply 87 % Internal current consumption 300 mA at 5 V Total current for I/O modules 1700 mA at 5 V Isolation 500 V system /supply Voltage via power jumper contacts DC 24 V (-15 % ... +20 %) Current via power jumper contacts max. DC 10 A

Technical Data

WAGO-I/O-PRO CAA 759-333 1

Miniature WSB Quick marking system plain 248-501 5 with marking see General Catalogue W4 Volume 3 pages 1.174 ... 1.175

General Specifications

Operating temperature 0 °C ... +55 °C Wire connection CAGE CLAMP® 0.08 mm2 ... 2.5 mm2; AWG 28 ... 14

8 ... 9 mm /0.33 in stripped length Dimensions (mm) W x H x L 51 x 65* x 100

* from upper edge of DIN 35 rail Weight ca 180 g Storage temperature -25 °C ... +85 °C Relative air humidity 95 % no condensation Vibration and acc. to IEC 60068-2-6 shock resistance acc. to IEC 60068-2-27 Degree of protection IP 20 EMC 1 -Immunity to interference acc. to EN 61000-6-2 (1999) EMC 1 -Emission of interference acc. to EN 50081-2 (1994)

Approvals

Accessories r see General Catalogue W4 Volume 3 Conformity marking 1

Item Pack.-unit No. pcs

EL

EC

TR

O

N

IC

S

ELECTRONICS

I/O modules

FI

EL

D B

U S

IN

TE

RF

A

C E

FI

EL

D B

U S

IN

TE

RF

A

C E

750-423 / 753-423

Subject to design changes WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 •D-32385 Minden Tel.: +49(0)571/887-0 E-Mail: info@wago.com

25.04.2007 Hansastr. 27 •D-32423 Minden Fax: +49(0)571/887-169 www.wago.com

4-Channel Digital Input Module AC / DC 24 V 2- to 3-conductor connection; with power jumper contacts

Fig. Series 750 / Technical data see page 30 / Delivery without Mini WSB marker Series 750 / 753 marking see pages 20 ... 21 / 22 ... 23

DI 2

Data contacts

24 V

DI 4

DI 1

DI 3

0 V

Power jumper contacts

DI 3

DI 1

Status

DI 4

DI 2

Status

13 14

15 16

13 14

C

D B

A

750-423

DI 2 DI 1

DI 3

DI

DI 4

0 V

24 V 24 V

0 V 270pF 270pF

Status

750-423

The digital input module receives control signals from digital field devices (sensors, etc.).

Each input module has a noise-rejection filter with a time constant.

An optocoupler is used for electrical isolation between the bus and the field side.

Attention:

An additional supply module must be added for operation with AC 24 V!

Description Item no. Pack.

unit

4DI 24V AC/DC, 50ms, power contacts 750-423 1 4DI 24V AC/DC, 50ms, power contacts (without connector)

753-423 1

Accessories Item no. Pack.

unit

Connectors Connectors Series 753 753-110 25 Coding elements 753-150 100

Miniature WSB Quick marking system plain 248-501 5 with marking see pages 214 ... 215

Approvals

Series 750 and 753 r UL 508 Conformity marking 1

Series 750 4 EN 50021 II 3 GD EEx nA II T4 4 r UL 1604 Class I Div2 ABCD T4A

Technical Data

No. of inputs 4 Current consumpton (internal) 10 mA Voltage via power jumper contacts DC 24 V (-15 % ... +20 %) Signal voltage (0) DC -3 V ... +5 V; AC 0 V .. 5V Signal voltage (1) DC 11 V ... 30 V; AV 10 V .. 27 V Input filter 50 ms Input current typ. DC 7.5 mA; AC 9.5 mA Isolation 500 V system / supply Internal bit width 4 bits Wire connection CAGE CLAMP®

Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Stripped length series 750 / 753 8 ... 9 mm / 0.33 in

9 ... 10 mm / 0.37 in Width 12 mm Weight approx. 50 g EMC 1-Immunity to interference acc. to EN 50082-2 (1996) EMC 1-Emission of interference acc. to EN 50081-1 (1993)

750-513 / 753-513

Subject to design changes WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 •D-32385 Minden Tel.: +49(0)571/887-0 E-Mail: info@wago.com

10.09.2008 Hansastr. 27 •D-32423 Minden Fax: +49(0)571/887-169 www.wago.com

2-Channel Relay Output Module AC 230 V, DC 30 V isolated outputs; 2 make contacts

Fig. Series 750 / Technical data see page 28 / Delivery without Mini WSB marker Series 750 / 753 marking see pages 16 ... 17 / 18 ... 19

DO 2

Data contacts relay 2 relay 1 Status

DO 1

Status

Power jumper contact

L 2 L 1

N

14 24

K1 K2

C

D B

A

13 23

750-513

L

Status

DO 24

750-513

The connected load is switched via the digital output (relay contacts) from the control system.

The internal system voltage is used to trigger the relay.

The NO contacts are electrically isolated.

The switched status of the relay is shown by a LED.

Actuators with a ground (earth) wire may be directly connected to the module.

Description Item no. Pack.

unit

2DO 230V AC 2.0A/ Relay 2NO/ Potential Free

750-513 101)

2DO 230V AC 2.0A/ Relay 2NO/ Potential Free / without power jumper

750-513/000-001 1

2DO 230V AC 2.0A/ Relay 2NO/ Potential Free (without connector)

753-513 101)

1) Also available individually

Accessories Item no. Pack.

unit

753 Series connector 753-110 25 Coding elements 753-150 100

Miniature WSB quick marking system, plain 248-501 5 with marking see pages 256 ... 257

Approvals

Series 750 and 753 Conformity marking 1 r UL 508 4 r ANSI/ISA 12.12.01 Class I, Div. 2, Grp. ABCD, T4

Series 750 4 EN 60079-15 I M2 / II 3 GD Ex nC IIC T4 Marine applications see "Approvals Overview" in section 1

Technical Data

No. of outputs 2 make contacts Current consumption max. (internal) 100 mA Switching voltage (max.) AC 250 V / DC 30 V Switching power 500 VA / 60 W (resistive load) cos � max. =0.4; L/R max = 7 ms Switching current (min.) 10 mA / 5 V DC Switching current (max.) AC / DC 2 A Switching rate (max.) 30 / min (at nominal load) Pull-in time (max.) 10 ms Bounce time (typ.) 1.2 ms Drop-out time (max.) 10 ms Contact material Silver alloy Mechanical life 2 x 107 switching operations Electrical life 3 x 105 switching operations

(AC 2 A / 250 V) or (DC 2 A / 30 V) Isolation 1.5 kV eff. (field/system)*;

* 2.5 kV rated surge voltage;

Overvoltage category III

Internal bit width 2 bits Wire connection CAGE CLAMP®

Cross sections 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 Stripped lengths (750 / 753 Series) 8 ... 9 mm / 0.33 in

9 ... 10 mm / 0.37 in Width 12 mm Weight 53.5 g EMC 1-Immunity to interference acc. to EN 50082-2 (1996) EMC 1-Emission of interference acc. to EN 50081-1 (1993) EMC marine applications - Immunity to interference acc. to Germanischer Lloyd (2003) EMC marine applications - Emission of interference acc. to Germanischer Lloyd (2003)

C

D B

A

750-600 rand marine applications see pages 1.10 ... 1.13

4 II 3 G EEx nA II T4, Class I Div2 ABCD T4A Conformity marking 1

Subject to design changes

General specifications

Item-No. Pack.-unit pcsDescription

Operating temperature 0 °C ... +55 °C Wire connection CAGE CLAMP® 0.08mm2 ... 2.5mm2; AWG 28 ... 14

8 ... 9mm/0.33 in stripped length Dimensions (mm) W x H x L 12 x 64* x 100

* from upper edge of 35 DIN rail Weight ca 35g Storage temperature -25 °C ... +85 °C Relative air humidity 95% no condensation Vibration and acc. to IEC 60068-2-6 shock resistance acc. to IEC 60068-2-27 Degree of protection IP 20 EMC 1 -Immunity to interference acc. to EN 50082-2 (1996) EMC 1 -Emission of interference acc. to EN 50081-1 (1993) EMC marine applications -Immunity to interf. acc. to Germanischer Lloyd (1997) EMC marine applications -Emission of interf. acc. to Germanischer Lloyd (1997)

Approvals

Accessories Item-No. Pack.-unit pcs

Delivery without miniature WSB

Miniature WSB quick marking system plain 248-501 5 with marking see pages 1.174 ... 1.175

After the fieldbus node is assembled with the correct buscoupler and selected I/O modules, the end module is snapped onto the assembly.

It completes the internal data circuit and ensures correct data flow.

One is required for each buscoupler.

End Module

End Module 750-600 10 1)

1) Also available individually

750-600

WAGO Kontakttechnik GmbH Postfach 2880 • D-32385 Minden Tel.: +49(0)5 71 /8 87-0 E-Mail: info@wago.com Hansastr. 27 • D-32423 Minden Fax.: +49(0)5 71 /8 87-169 www.wago.com21.01.2004

File details come from the government source that posted it. Updated .