Technical Training.docx

DOCX document 20 KB Posted

Attached to
B1326 HVAC Design Build, Eglin AFB Federal contract opportunity
Solicitation number
FA282321R0020
Issued by
Department of the Air Force Materiel Command Test Center

About this file

This document outlines technical training requirements and a related federal contract opportunity. The technical training requirements specify that the contractor shall provide sixteen hours of manufacturer technician level training for two fire alarm technicians from Eglin Air Force Base. The training includes eight hours of off-site maintenance and operation instruction and eight hours of on-site familiarization training for the fire alarm system installed.

The related federal contract opportunity is solicitation number FA282321R0020 from Eglin Air Force Base, Florida for design-build services for the HVAC system in Building 1326. The requirement is classified under NAICS code 238220 with a size standard of $16.5 million. The statement of magnitude is between $1 million to $500 million. This is a 100% small business set-aside utilizing best value selection and awarding based on best value to the government. The work includes design-build of HVAC ductwork, AHUs, controls and associated equipment, and modification or replacement of fire suppression and alarm systems. Performance period is 330 days after notice to proceed. The soliciting agency is the Department of the Air Force Materiel Command Test Center.

View the file

Other files for this federal contract opportunity

Other files attached to B1326 HVAC Design Build, Eglin AFB, newest first.
File Type Posted
30 Jun 21 - FTFA161016_Additional RFI Questions.docx DOCX document
Attachment 13 - FTFA 16-106 SOW Amendment 2_B1326_062821.pdf PDF
FTFA161016_Site visit_RFIs_062821.xlsx XLSX spreadsheet
Solicitation Amendment FA282321R00200004 SF 30.pdf PDF
FTFA161016_Site visit_RFIs_062521_Rev.xlsx XLSX spreadsheet
Eglin DDC System and Network with Lockable enclosure and Cybersecurity requirements.docx DOCX document
MNS Eglin Mass Notification System Messages Script (Sep 17).pdf PDF
08 Apr 21_Chris Cahill_ FA Matrix explanation.pdf PDF
FTFA161016_Site visit_RFIs_062521.xlsx XLSX spreadsheet
07 May 21_Eglin Fire Suppression Specific Criteria April 22 2021.xls XLS spreadsheet
07 May 21_Fire sys Requirements Mar 2021.docx DOCX document
Attachment 12 - BLDG 1326 Drawing Set.pdf PDF
Attachment 10a - SIte Visit Sign In_061421.pdf PDF
Attachment 11d - Mech Rm 2.docx DOCX document
Attachment 11c - Generator area.docx DOCX document
Attachment 11a - Mech Rm 1..docx DOCX document
Attachment 11b - Comm Rm.docx DOCX document
Solicitation Amendment FA282321R00200003SF30.pdf PDF
Attachment 4 - Section L with attachments_5.pdf PDF
Attachment 10 - Site Visit Sign in Sheet_052521.pdf PDF
Solicitation Amendment FA282321R00200002 SF 30.pdf PDF
Attachment 4 - Section L with attachments_4.pdf PDF
B1326 Map.JPG JPG image
50 Div Cost.xls XLS spreadsheet
Attachment 4 - Section L with attachments_3.pdf PDF
Attachment 4 - Section L with attachments_2.pdf PDF
Solicitation Amendment FA282321R00200001 SF 30.pdf PDF
Attachment 1 - FTFA 16-1016 HVAC B1326 SOW_1.pdf PDF
Attachment 9 - Reference Figure BLDG 1326 RENOVATION 3.pdf PDF
Attachment 3 - Wage Determination.pdf PDF
Solicitation - FA282321R0020.pdf PDF
Attachment 4 - Section L with attachments_1.pdf PDF
Attachment 5 - Section M.pdf PDF
Attachment 6 - Eglin Fire Suppression Specific Criteria April 22 2021.pdf PDF
Attachment 7 - Fire sys Requirements Mar 2021.pdf PDF
Attachment 8 - Reference Figure BLDG 1326.pdf PDF
Attachment 2 - FTFA 16-1016 SOW Amendment HVAC B1326.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA training requirements

Technical Training The Contractor shall provide manufacture technician level training for two of Eglin's fire alarm technicians. Training shall include the follow:

a.Eight (8) hours of off-site maintenance and operation training for the fire alarm system installed. Training shall take place at the closest available location where the manufacture trains technicians.
b.Eight (8) hours of on-site familiarization training for the entire fire alarm system installed.