F19_-_FURNACE_-_AC-_REPLACENENT_138_W_Addison_(1).docx
DOCX document 39 KB Posted
- Attached to
- 138 W Addison St. - Install Furnace and A/C Unit
- Solicitation number
- 2025-COMMUNITY DEVELOPMENT-030
- Issued by
- Kalamazoo County, Huntington Woods City, Michigan
About this file
This document is a Work Write-Up for a furnace and air conditioning replacement project prepared by the City of Jackson, Michigan, for a residential property located at 138 W Addison Street. The project involves replacing the existing furnace with a new 95% efficient, gas-fired forced air furnace that meets Michigan Mechanical Code standards and NWAHA heating requirements. The scope includes installing a new AC unit with an Energy Star rating, new ductwork, registers, a thermostat, and a filter rack, with potential electrical and plumbing modifications as needed to comply with local codes.
The work write-up does not specify exact pricing details or funding sources, but it appears to be part of a municipal home improvement or rehabilitation program. The document includes spaces for the homeowner (Lisa R. Weathers), contractor, and a construction specialist to review and approve the scope of work, indicating a structured process for project implementation. The project aims to improve the residential property's heating and cooling systems to enhance energy efficiency and comfort while adhering to local building and mechanical standards.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Work Write-Up
F19 - FURNACE - AC- REPLACENENT.
* EXHIBIT 1 *
Dated: 12/13/2024
CUSTOMER INFORMATION
WEATHERS LISA R
138 W ADDISON, JACKSON, MI 49203
PREPARED BY
sharrison@cityofjackson.org
* NOTE *
THE CUSTOMER AND CONTRACTOR MUST SIGN THE BOTTOM OF EACH PAGE ONLY IF
1) THIS WORK WRITE-UP BECOMES PART OF A CONSTRUCTION CONTRACT
2) THE UNDERSIGNED CUSTOMER AND CONTRACTOR HAVE REVIEWED, APPROVED AND AGREED TO THE WORK AND PRICES DESCRIBED IN THIS WORK WRITE-UP
Location: Unassigned
| General Requirements |
| Quantity |
| Units |
| Total |
1 - F19 - FURNACE/ AC Unit - REPLACE (Specification ID:1.19000 Estimated Qty:0)
* PERMIT REQUIRED *
Replace existing furnace with new 95% efficient forced air, gas fired furnace bearing AGA label. Furnace output capacity shall be sufficient to heat the structure according to NWAHA standards. Installations shall comply with the current Michigan Mechanical Code. All habitable rooms, as designated by the Building Inspector, shall be supplied with warm air sufficient to maintain temperatures according to NWAHA standards. All new register installations shall be located in floor or low wall with the exception of bathrooms, which shall be wall mounted. Provide an adequate means of return air for these new supply runs. The use of ceiling diffuser outlets will be allowed only with prior approval. When new supply or returns are required and duct is run through any habitable room, it shall be enclosed in new or existing walls. Any new enclosure shall match existing surfaces. Installation shall include a register in the warm air plenum or trunkline to provide heat to the cellar and a new thermostat. A filter rack with cover shall be installed in the return air duct outside of the furnace cabinet. Whenever possible, insulate new supply and return ducts in unheated attic spaces, ventilated crawl spaces, and other exposed locations to prevent excessive heat loss. Flexible duct shall be used only in attics or crawl spaces. If not bid As a separate part of this contract, the installation shall include repair or replacement of wiring and/or plumbing necessary to comply with local code. If the existing ductwork is not to be replaced, it must be approved by the Mechanical Inspector and:
AC unit, sized accordingly, installed to manufacturer instructions and have a energy start rating.
Electrical by others.
Total
Prepared By: sharrison@cityofjackson.org on 12/13/2024
OWNER ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and received a copy. I fully understand the repairs to be made to my property.
| x_________________________ | __________ | |
| Owner: | Date |
CONTRACTOR ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and agree to perform all work called for in accordance with the bid submitted on __________.
| x_________________________ | __________ | |
| Contractor | Date |
| x____________________________ | __________ | |
| Construction Specialist | Date |
| Prepared By: sharrison@cityofjackson.org on 12/13/2024 |
| 3 of 3 |
image1.png
File details come from the government source that posted it. Updated .