F19_-_FURNACE_-_AC-_REPLACEMENT_138_W_Addison_(1)_Specs.pdf

PDF 140 KB Posted

Attached to
138 W Addison St. - Install Furnace and A/C Unit
Solicitation number
2025-COMMUNITY DEVELOPMENT-030
Issued by
Kalamazoo County, Huntington Woods City, Michigan

About this file

This is a Work Write-Up document prepared by the City of Jackson for a furnace and air conditioning replacement project located at 138 W Addison Street in Jackson, Michigan. The document details a comprehensive HVAC system replacement, specifically requiring the installation of a new 95% efficient forced air, gas-fired furnace bearing an AGA label and a new AC unit with an energy star rating. The project requires a permit and must comply with the current Michigan Mechanical Code, with installation specifications including precise requirements for register placement, ductwork, insulation, and heating standards as defined by NWAHA (Northwest Home Heating Association).

The work write-up does not specify exact pricing but indicates that electrical work will be completed by others. The document includes signature lines for the owner, contractor, and a construction specialist to accept the scope of work, suggesting this is part of a potential municipal home improvement or rehabilitation program. The technical specifications are detailed, requiring the new HVAC system to sufficiently heat all habitable rooms, with specific guidelines for register placement, duct enclosure, and system efficiency. The document was prepared on 12/13/2024 and is marked as Exhibit 1, indicating it is part of a larger set of project documentation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Prepared By: sharrison@cityofjackson.org on 12/13/2024

Work Write-Up

F19 - FURNACE - AC- REPLACENENT.

* EXHIBIT 1 *

Dated: 12/13/2024

CUSTOMER INFORMATION

WEATHERS LISA R

138 W ADDISON, JACKSON, MI 49203

PREPARED BY

sharrison@cityofjackson.org

* NOTE *

THE CUSTOMER AND CONTRACTOR MUST SIGN THE BOTTOM OF EACH PAGE ONLY IF

1) THIS WORK WRITE-UP BECOMES PART OF A CONSTRUCTION CONTRACT

2) THE UNDERSIGNED CUSTOMER AND CONTRACTOR HAVE REVIEWED, APPROVED AND

AGREED TO THE WORK AND PRICES DESCRIBED IN THIS WORK WRITE-UP

Prepared By: sharrison@cityofjackson.org on 12/13/2024

Location: Unassigned

General Requirements Quantity Units Total

1 - F19 - FURNACE/ AC Unit - REPLACE (Specification ID:1.19000 Estimated Qty:0)

* PERMIT REQUIRED *

Replace existing furnace with new 95% efficient forced air, gas fired furnace bearing AGA label. Furnace output capacity shall be sufficient to heat the structure according to NWAHA standards. Installations shall comply with the current Michigan Mechanical Code. All habitable rooms, as designated by the Building

Inspector, shall be supplied with warm air sufficient to maintain temperatures according to NWAHA standards. All new register installations shall be located in floor or low wall with the exception of bathrooms, which shall be wall mounted. Provide an adequate means of return air for these new supply runs. The use of ceiling diffuser outlets will be allowed only with prior approval. When new supply or returns are required and duct is run through any habitable room, it shall be enclosed in new or existing walls. Any new enclosure shall match existing surfaces. Installation shall include a register in the warm air plenum or trunkline to provide heat to the cellar and a new thermostat. A filter rack with cover shall be installed in the return air duct outside of the furnace cabinet. Whenever possible, insulate new supply and return ducts in unheated attic spaces, ventilated crawl spaces, and other exposed locations to prevent excessive heat loss. Flexible duct shall be used only in attics or crawl spaces. If not bid As a separate part of this contract, the installation shall include repair or replacement of wiring and/or plumbing necessary to comply with local code. If the existing ductwork is not to be replaced, it must be approved by the Mechanical Inspector and:

AC unit, sized accordingly, installed to manufacturer instructions and have a energy start rating.

Electrical by others.

Total

Prepared By: sharrison@cityofjackson.org on 12/13/2024 3 of 3

OWNER ACCEPTS SCOPE OF WORK

I have read the contents of this work write up and received a copy. I fully understand the repairs to be made to my property.

x_________________________ __________ Owner: Date

CONTRACTOR ACCEPTS SCOPE OF WORK

I have read the contents of this work write up and agree to perform all work called for in accordance with the bid submitted on __________.

x_________________________ __________ Contractor Date x____________________________ __________

Construction Specialist Date