F16SOL10044
x x
1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT
THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
OCON
Washington DC 20013-7012
MRC 1200
P.O. BOX 37012
OCON
OCON
Washington DC 20013-7012
MRC 1200
P.O. BOX 37012
SMITHSONIAN INSTITUTION
163310906/10/2016000005
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
06/10/2016
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not, is required to sign this document and return __________________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
Solicitation Number F16SOL1004 is hereby amended as follows:
Amendment #5
The proposal due date has been extended from July 18, 2016 to July 21, 2016 proposals due at 3:00pm
Attached and incorporated into this solicitation are the 14 pages attached
Outside of the changes referenced above, Solicitation F16SOL10044 remains unchanged.
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
Dorothy A. Leffler
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
NSN 7540-01-152-8070
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 1 of 15
Renewal of the Police Station and Replacement of the Public Restrooms, Pavilion and Site Utilities Solicitation Number: F16SOL10044 ‐ BID AMENDMENT 05 DATED 07/13/16
ITEM QUESTION ANSWER
Questions 001 – 103 see Bid Amendment #04
104 This project includes a lot of operational security infrastructure to be “re‐routed” from one security location to another without incurring downtime
The point numbers are on three (3) RS485 to fiber modules.
105 There are no drawings of existing equipment, or of the existing security control center
Information will be provided for coordination only after contract award.
106 We would likely need a lot of fiber media converters to be used temporarily while the new Security Control Center is completed
The point numbers are on three (3) RS485 to fiber modules.
107 No information about the fiber plant which would probably be used to “re‐route” the security circuits is included
There are 144 strands of existing MM fiber between the Police Station and Lion & Tiger. Refer to drawing 2TN0.02.
108 It appears that there is/are a missing document(s) or drawing set(s) ‐ Where is says “Replace note 1...” , there is no note 1
Revised drawing 1TY002 with bubbled changes was included as part of Amendment 1 via the Dropbox link posted in the FedBizOpps solicitation. Additional “narrative only” revisions to 1TY002 were included in Amendment 3.
109 It appears that there is/are a missing document(s) or drawing set(s) ‐ Where is says “Replace note 8…” there is no note
Amendment 1 via the Dropbox link posted in the FedBizOpps solicitation.
Additional “narrative only” revisions to 1TY002 were included in Amendment 3.
110 It appears that there is/are a missing document(s) or drawing set(s) ‐ “Add note 9…” there are no notes 1‐8
Amendment 1 via the Dropbox link posted in the FedBizOpps solicitation.
Additional “narrative only” revisions to 1TY002 were included in Amendment 3.
111 Reference: Amendment #04 Item 102, 3E601 & 02 Comment: Existing Red/Blue 15kv feeders are 3‐ 1/C, # 1/0.
All new 15kv feeders are clearly indicated 3‐ 1/C, # 1/0.
Increasing 15kv feeders to 250kcmil is way oversized and very costly.
Question: Which 15kv feeder size is correct Q/A #102 with 3‐ 1/C, #250 or Drawings with 3‐ 1/C, # 1/0?
All new 15 KV feeders shall be 250 KCMIL
112 Drawings and specs dated 6/3/16 indicate that the Contractor is to provide the trash receptacles. Is that correct?
Per the Amendment 1 (June 24, 2016) Dropbox link posted in the FedBizOpps solicitation: Drawing 2L001 was updated to indicate that trash
Page 1 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 2 of 15 receptacles will be provided by Smithsonian/National Zoo, and the reference to trash receptacles was removed from spec 129300 Site Furnishings.
113 The bid schedule states that bids are to be based on specs and drawings dated 5/5/16. Is that correct?
Bids are to be based on specifications and drawings dated 6/3/16, and all solicitation amendments.
114 On this project I am sending a substitution request for Polycoat‐Aquaseal 5000 under section 071326 self‐adhering sheet waterproofing.
This substitution request will be evaluated after award if requested by a contractor utilizing the instructions contained in Clause – L.3 52.211‐6 Brand Name or Equal. (AUG 1999) and Specification Section 012500 Substitution Procedures.
115 Drawing 1A605 / detail E9 shows a Level 3 bullet resistant panel to be installed will gyp board & framing, but there is no mention of this in the specifications (IE provide information / requirements). Please provide specification information for this panel.
See added specification section 102641 Bullet Resistant Panels in addendum, dated July 12, 2016.
116 There are many references in the specifications for allowances (examples: access doors & frames and testing & inspections). Are there values that we are supposed to carry for these activities and if so, what is the value the contractor needs to carry for this in the estimate?
Contractor shall include all associated costs as required.
117 It was mentioned at the site visit (7/6/16) that there will be no PEPCO costs that will need to be carried by the contractor in order to do the electrical substation work and the owner will provide power feeders from a separate project in order to assist with the new electrical substation switchover. Please confirm that this is correct.
It is correct the PEPCO Service stops at the Hawthorn Street Substation. SI owns and operates all downstream service. SI will shut off the RED BLUE Feeders for the contractor to disconnect once and reconnect once.
Contractor is required to provide all other temporary and new service as required under this contract. Contractor will coordinate the substation fuse upgrade with SI.
118 Spec Section 014000 references a quality control personnel requirement on the project but does not specify if this means carrying a quality control manager on the project. Is a separate full time / on site quality control manager that is not the superintendent, project manager and/or personnel that have other contractor duties a requirement for this project?
Yes a qualified individual may perform other project related duties than QC work, but mat not the project’s lead superintendent.
Page 2 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 3 of 15
119 Spec section 102113.19 paragraph 2.1.A.1 states that the plastic toilet compartments must have a flame‐spread index of 25 or less, the classification for a Class A fire rating.
Paragraph 2.1.B states that the product must have a Class B fire rating. Please clarify whether the plastic toilet compartments must meet Class A or Class B fire rating.
The plastic toilet partitions must meet a Class B Material Fire Rating and ALSO meet a Flame‐Spread Index of 25 or less, and a Smoke‐Developed Index of 450 or less. While these Surface‐burning Characteristics indicated are also associated with a Class A material fire rating, these are not the only requirements to meet a Class A rating.
120 Please confirm what permit fees / expediting the contractor will be responsible for on this project.
The civil engineer will submit the Erosion Control and Stormwater Management drawings for review and permitting by DOEE and pay the Initial fees during filing. The Contractor will be responsible for Final fees for Erosion Control and Stormwater Management and will be responsible for picking up the approved drawings and permit. The Contractor will also be responsible for any DOEE‐required inspection fees during construction, to be determined during the erosion control and stormwater reviews.
Permit expediting by the Contractor is not anticipated.
121 Reference Amendment #04 Item 102, 3E601 & 02. The existing Red/Blue 15kv feeders are 3‐ 1/C, # 1/0. All new 15kv feeders are clearly indicated 3‐ 1/C, # 1/0. Increasing 15kv feeders to 250 kcmil is way oversized and very costly. Please clarify which 15kv feeder size is correct Q/A #102 with 3‐1/C, #250 or Drawings with 3‐ 1/C, # 1/0?
SEE QUESTION #111
Page 3 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 4 of 15
SUMMARY OF REVISIONS TO CONTRACT DOCUMENTS
ISSUE: Addendum
DATE: 7.12.2016
PROJECT NAME: Renew Police Station, Replace Public Restrooms and Pavilion and Electrical Substation
PROJECT NUMBER: 1633109
OWNER: Smithsonian Institution / National Zoological Park
The first table below contains line-by-line revisions made to the specifications that were issued with the Bid Documents dated 6/3/2016.
The second table below provides a summary of revisions to the drawings that were issued with the Bid Documents dated 6/3/2016. Please refer to the clouded drawings issued with the Addendum for the substance of the revisions.
CHANGES TO SPECIFICATIONS
Section Description
Volume 1
102641 Add Specification Section
Volume 2
Not Used
SUMMARY OF CHANGES TO DRAWINGS
Sheet Number Description
CIVIL
2 CS 521 Revise Bollard Detail
LANDSCAPE
Page 4 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 5 of 15
Sheet Number Description
ARCHITECTURAL
Volume 1
1A 102 Removed ADA bollard
1A 201 Located Push-button actuator on building elevation
1A 507 Removed ADA bollard
1A 508 Located Push-button actuator on building elevation
2A 5 05 Revised ADA bollard details
STRUCTURAL
PLUMBING
MECHANICAL
ELECTRICAL
FIRE ALARM / FIRE SUPRESSION
TECHNOLOGY / AV-IT
Page 5 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 6 of 15
Sheet Number Description
Not Used
SECURITY
End of Summary
Page 6 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 7 of 15
JUNE 3, 2016
FINAL CONSTRUCTION DOCUMENTS-
Addendum, July 12, 2016
SMITHSONIAN FACILITIES
PROJECT #1633109
VOLUME 1 - POLICE
BULLET RESISTANT PANELS 102641- 1
SECTION: 102641 BULLET RESISTANT PANELS
PART 1 – GENERAL
1.1 SUMMARY
A. Section includes bullet resistant fiberglass panels.
1.2 REFERENCES
A. American Society for Testing and Materials:
1. ASTM E119-98 Standard Test for One-Hour Fire-Rating of Building Construction and Materials
2. ASTM F1233-98 Standard Test Method for Forced Entry Testing of Materials/Assemblies, Class IV
B. International Organization for Standardization:
1. ISO 9001:2008 Quality Management System C. National Institute of Justice Ballistic Standards:
1. NIJ Standard 0108.01 – Type III-A D. Small Business Administration:
1. SBA Small Business Size Standard E. Underwriters Laboratories:
1. UL 752 Specifications and Ammunition, 11th Edition, Standard for Bullet Resisting Equipment published September 9, 2005, revised December 21, 2006, Level 3
F. The United States Department of State:
1. The International Traffic in Arms Regulations (ITAR)
1.3 SUBMITTALS
A. Submittals for Review: Submit for approval prior to fabrication.
1. Product Data: Include specifications, brochures, and samples.
2. Recommendations for installation of Bullet Resistant Fiberglass Panels.
B. Certificates: Submit printed data to indicate compliance with following requirements.
1. UL LISTING Verification and UL752 Current Test Results as provided by Underwriters
Laboratories.
2. ASTM E119-98 One-Hour Fire Rating of Building Construction and Materials.
3. ASTM F1233-98 Standard Test Method for Forced Entry Testing of Materials/Assemblies.
4. Manufacturer’s third party certificate of registration with ISO 9001:2008.
5. Manufacturer’s U.S. Dept. of State ITAR Statement of Registration.
6. Manufacturer’s SBA Profile verifying small business status by the SBA.
1.4 DELIVERY, HANDLING, AND STORAGE
A. Deliver materials to project with manufacturer’s UL LISTED Labels intact and legible.
B. Handle material with care to prevent damage. Store materials inside under cover and stack flat and off the floor.
1.5 WARRANTY
A. Warrant all materials and workmanship against defects for a period of ten (10) years from the date of Substantial Completion.
Page 7 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 8 of 15
JUNE 3, 2016
FINAL CONSTRUCTION DOCUMENTS-
Addendum, July 12, 2016
SMITHSONIAN FACILITIES
PROJECT #1633109
VOLUME 1 - POLICE
BULLET RESISTANT PANELS 102641- 2
PART 2 – PRODUCTS
2.1 MANUFACTURER
A. Basis of Design: ArmorCore by Waco Composites, (Waco, TX 76710, phone: 254-752-3622, toll free: 866-688-3088, email: sales@armorcore.com, web: www.armorcore.com) or Smithsonian Institution approved alternate.
2.2 PERFORMANCE CRITERIA
A. Bullet Resistant Fiberglass Panels shall be “non ricochet type” to permit the encapture and retention of an attacking projectile lessening the potential of a random injury or lateral penetration.
B. Panel Rating: UL752 Level 3.
C. Bullet resistance of joints: equal to that of the panel.
2.3 MATERIALS
A. Panels fabricated of multiple layers of woven roving ballistic grade fiberglass cloth impregnated with a thermoset polyester resin and compressed into flat rigid sheets.
B. Thickness: 7/16” nominal thickness C. Nominal Weight: 4.8 lbs. per sq. ft.
D. Available Panel Sizes: 4’ x 8’ E. Panels manufactured in the United States of America with raw materials sourced from the
U.S.A. for quality assurance purposes and to comply with any applicable “Buy American” provisions.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Prior to starting installation, verify work of related trades required in contract documents and architectural drawings is complete to the point where work of this Section may properly commence.
3.2 JOINTS
A. Reinforce joints with a back-up layer of bullet resistive material. Minimum width of reinforcing layer at joint shall be 4-inches, centered on panel joints.
3.3 APPLICATION
A. Install armor in accordance with manufacturer’s printed recommendations and as required by contract documents.
B. Secure armor panels using screws, bolts, or an industrial adhesive.
1. Method of application shall install panels minimizing vulnerabilities by fitting tightly to adjacent surfaces including concrete floor slab, concrete roof slab, bullet resistive door frames, bullet resistive window frames, and the like.
END OF SECTION 102641
Page 8 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 9 of 15
Smithsonian Facilities
600 Maryland Avenue S.W. Suite 5001
Washington, DC 20024-2520
KEY PLAN
GRAPHIC SCALE(S)
A
1 2 3 4 5 6 7 8 9 10 11 12
B
C
D
E
F
G
H
J
K
L
M
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
J
K
L
M
SHEET NO.
21445
RENEW POLICE STATION, REPLACE
PUBLIC RESTROOMS AND PAVILION,
AND ELECTRICAL SUBSTATION
NZP
3001 Connecticut Avenue, NW
Washington, DC
1633109
Cho Benn Holback + Associates
100 N. Charles St, Baltimore, MD 21201
06/03/16
FINAL CONSTRUCTION DOCUMENTS
DJCS MAE
JMH
RESTROOMS - SITE DETAILS
Page 9 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 10 of 15
X6
XA
X5X4X3X2
XB
XC
X1
131 SF
LOBBY
299 SF
RECEPTION
203 SF
OHS
SUITE
55 SF
TOILET
161 SF
EXAM 2 /
AUD/RESP
8 SF
MEDS
225 SF
WORKSTATIONS
98 SF
EXAM 1
111 SF
EXAM 3 /
SPEC LAB
49 SF
BREAK
ROOM
221 SF
CORRIDOR
318 SF
NZPP
TRAINING
ROOM
34 SF
JANITOR
56 SF
TOILET
56 SF
TOILET
422 SF
OPS
CORRIDOR
403 SF
ROLL
CALL
196 SF
ASST.
CHIEF'S
OFFICE
169 SF
LIEUTENANT'S
OFFICE
193 SF
CHIEF'S
OFFICE
73 SF
COPY
AREA
97 SF
SUPERVISOR'S
OFFICE
62 SF
ID OFFICE
271 SF
SGT.
WORKSTATIONS
62 SF
VESTIBULE
58 SF
ELEV
H7
A-301
H7
A-301
H1
A-301
H1
A-301
A-202 A1
79 SF
ID OFFICE
PUBLIC
XD
A-401
H1
1A
1F
201A
221A
221B
224B
216217 215
224A
210B
207B
207A
230B
204B
201B
204A
A-403
E10
A-403
A10
13C
08 5653.1
08 5653.1
22 1000.2
06 4113
22 1000.3
13C 9E 13C 13C
1F 1G
13C 13C
13C
1F
1F
1F
1F
1F
13C1G
1E
13C
13C
9J
1A1F
1F1F
13C
1F
13C
7A
1F
7A
7A
1F 1F
1F13C
1F
1F
1F
8A
9J
1G
1E
1G
1C
W2
W3
W4 W4
W5
W6
W6
W6
W21
W21
W6
W6
W6
W5
W4 W4
1F
186 SF
STAIRS
230 B
E.9
5.1
15' - 5 1/4"
XE
R1
W2 W13
W14AW14
2' -8
A-531J10
A-532
J10
A-532
J1
9'
/2
D7
A-301
D7
A-301
A-531
J1
A-531
D1
A-301
D1
A-301
E10
A-531
E7
13C 13C
1F
1F
13C 13C
1F
13C 9E 13C 9E 13C 9E 13C
13C
9E
22 1000.2
06 4113
22 1000.2
06 4113
22 1000.2
06 4113
8A
9E 13C 9E
13C
1E 9A
9J9H
1C
1F
13C
13C
13C
ALIGN
ALIGN
ALIGN
ALIGN
A
LI
G N
A
LI
G N
A
LI
G N
A-511
J10
A-511
J7
TYP
5'
ALIGN
9' - 3 1/2" 5' - 4" 24' - 1"
15' - 1"
5'
/8
7' - 2 1/8"
ALIGN
13' - 10 3/8" 11' - 8 3/4" 13' - 6 3/4" 5' - 0"
10' - 0"
/4
/8
/2
/4
7'
/4
9' - 10 3/8"
14' - 4 7/8" 3' - 10 3/8" 9' - 8" 2' - 9"
4' - 5 1/4"
/8
13C
13C
13C
13C 13C 13C
2'
/2
1E
10 4400.1
A-202 A10
8"
18' - 10 3/4"4' - 8 3/4"2' - 0 1/8"7' - 11"
1' - 3" 1' - 3"
4" 9J
9J
1A
9L
1E
1G 1G
A
LI
G N
A
LI
G N
ALIGN
ALIGN
3/
8"
W7 W7 W7A
2'
1' - 0"
6"
A-508
E1
W3
A-532
A7
A-201
G1
NEW INFILL WALL
BELOW WINDOW
SILL
A7 A-502
1'
W1 W1
4"
2' - 6"
A-201
A1
A-202G1
WALL
MOUNTED
LIGHT
FIXTURE
6"
FW
RETAINING
WALL - SEE
CIVIL
7A
A4 A-532
A-532
A10
1F 1F
ABBREVIATIONS REFERENCED FROM THE CONSTRUCTION SPECIFICATIONS
INSTITUTE'S UNIFORM DRAWING SYSTEM TERMS AND ABBREVIATIONS MODULE.
CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS BEFORE
PROCEEDING WITH THE WORK.
DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
DRAWINGS TO NOT SCALE AND SHALL NOT BE SCALED.
ALL GIVEN DIMENSIONS TO BE VERIFIED IN FIELD.
SIZE METAL FRAMING GAUGE TO ACCOMMODATE INTERIOR WIND PRESSURES
CAUSED BY 14'-0" NOMINAL LOWER FLOOR FRAMING SPAN.
SIZE METAL FRAMING GAUGE TO ACCOMMODATE INTERIOR WIND PRESSURES
CAUSED BY PROVIDING FULL HEIGHT WALLS AT THE UPPER LEVEL TO UNDERSIDE
ROOF DECK
CONFIRM ALL FINISH GRADE SPOT ELEVATIONS SHOWN WITH CIVIL AND
LANDSCAPE DRAWINGS.
SEAL ALL CONDUIT AND RACEWAY PENETRATIONS THROUGH ANY WALL, FLOOR,
OR CEILING.
REFER TO A7.G003 FOR TYPICAL DEVICE ELEVATION
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1/8"=1'-0"
4' 8' 16'
TRUE NORTH
Smithsonian Facilities 600 Maryland Avenue S.W. Suite 5001
Washington, DC 20024-2520
Smithsonian Institution
GRAPHIC SCALE(S)
A
1 2 3 4 5 6 7 8 9 10 11 12
B
C
D
E
F
G
H
J
K
L
M
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
J
K
L
M
SHEET NO.
OF
PROJECT TITLE
A/E PROJECT NUMBER
ADDRESS
BUILDING NAME
PROJECT NUMBER
DRAWING TITLE
DRAWING TYPE
WORKING STAFF
STAMP
DATE
REVISION # DATE
SUBMISSION
REVISION DESCRIPTION
PROJECT NORTH
FOR
CONSTRUCTION
TYPE
DRAWN BY
SEQUENCEDISCIPLINE
CHECKED BYDESIGNED BY
:0 :2
A M
RENEW POLICE STATION,
REPLACE PUBLIC RESTROOMS
AND PAVILION, AND
ELECTRICAL SUBSTATION
POLICE - UPPER FLOOR PLAN
21445
ARCHITECTURAL
46 319
RENEW POLICE STATION, REPLACE
PUBLIC RESTROOMS AND PAVILION,
AND ELECTRICAL SUBSTATION
A
B Y
A p p ro ve r
F
IN
A L C O N S
TR
U C
TI
O N
D O C U M E N
TS
NZP
3001 Connecticut Avenue, NW Washington, DC
NZP
1633109
Cho Benn Holback + Associates
100 N. Charles St, Baltimore, MD 21201
CBH
1A
CBHCBH
1 02
06/03/16 FINAL CONSTRUCTION DOCUMENTS
SCALE = 1/4" = 1'-0"A-201 A-102
A1 UPPER FLOOR PLAN
KEYNOTE LEGEND
06 2023 INTERIOR FINISH CARPENTRY - SEE ARCHITECTURAL DRAWINGS
06 4113 WOOD VENEER-FACED ARCHITECTURAL CABINETS
08 5653.1 BULLET RESISTANT LEVEL 3 MANUAL SLIDING SERVICE WINDOW
10 4400.1 FIRE EXTINGUISHER CABINET
12 3600.1 SOLID SURFACE COUNTERTOP
22 1000.2 SINK, REFER TO PLUMBING DRAWINGS
22 1000.3 MOP SINK
1 6/24/16 Addendum 3 7/12/16 Addendum
Page 10 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 11 of 15
Lower Level 67'-0"
Roof Bearing 92'-0"
Upper Level 82'-0"
X6X5X4X3X2X1
H7
A-301
'-0
(4
2)
'-0
(3
8)
SYNTHETIC SLATE SHINGLE ROOF
COPPER GUTTER - 7"D X 5"W
MATCH EXISTING COPPER WRAPPED TRIM
EXISTING STONE VENEER
EXISTING COMPOSITE TILE ROOF TO REMAIN
EXISTING GUTTER - CAP END AT NEW WALL
STONE VENEER -
TYP
PAINTED HOLLOW
METAL DOORS
LIMESTONE
COPING
ALUMINUM CURTAIN WALL SYSTEM
A7
A-301
107C
W11
PLANTER WALL WITH STONE
VENEER AND STONE COPING
STONE SHELF
EXISTING STONE
VENEER
EXISTING DOWNSPOUT - MODIFY TO COORDINATE WITH
NEW GARAGE GEOMETRY AND TIE TO STORMWATER
SYSTEM BELOW GRADE - SEE CIVIL DRAWINGS
EXISTING DOWNSPOUT -
MODIFY TO DRAIN TO
BIORETENTION PLANTER- SEE
CIVIL DRAWINGS
COPPER DOWNSPOUT - 3" x 4" - TIE TO STORM
WATER SYSTEM - SEE CIVIL DRAWINGS
5.1
66'-9" ADDITION
'-3
/2
2'-2" 2'-8" 2'-8" 2'-8" 20'-9 1/4"
'-2
/2
"1' -3
8"
8" 8"
8"
COPPER DOWNSPOUT - 2" X 3" - TIE TO
STORMWATER SYSTEM - SEE CIVIL DRAWINGS
COPPER FLASHING
A-502
E7
9' -2
/4
W7AW7W7
W8
CJ
8'-0"
CJ
COPPER FLASHING
J1 A-506
TYP
COPPER GUTTER - 5"W X 3"D
EXISTING GUTTER - CAP END AT NEW
WALL
PATCH EXISTING COMPOSITE ROOF AT REMOVAL OF EXISTING VTR PER
1PD/102 KEYNOTE 16. REPAIR TO BE COMPLETED IN ACCORDANCE WITH
ORIGINAL MANUFACTURERS RECOMMENDATIONS FOR REPAIRS;
MAINTAINING EXISTING ROOF WARRANTY
COPPER SNOW
GUARD - TYP
EXTERIOR LIGHT
FIXTURE - TYP
EQ10'-0"EQ
Lower Level 67'-0"
Roof Bearing 92'-0"
Upper Level 82'-0"
X6 X5 X4 X3 X2 X1
H7
A-301
'-0
(3
8)
'-0
(4
2)
EXISTING COMPOSITE TILE ROOF TO REMAIN
MATCH EXISTING COPPER WRAPPED TRIM
EXISTING STONE VENEER
ALUMINUM INSULATED WINDOWS
WITH MUNTIN SYSTEM
EXISTING STONE SILL TO REMAIN
- TYP
GRADEW4W4
W3
W2W2
W3
W4W4
EXISTING DOWNSPOUT TO REMAIN
5.1
W13
W14W14A
NEW STONE INFILL - REMOVE
SURROUNDING STONE AS REQUIRED
TO TOOTH STONE INTO EXISTING
PATTERN
+/- 3'-8 1/2" VIF
NEW STONE SILL - MATCH TYPICAL
EXISTING SILL PROFILE -
CONTRACTOR TO REMOVE SILL,
DOCUMENT SPECIFID HISTORIC
PROFILE, COLOR, TEXTURE, AND
APROVIDE INFORMATION IN
SUBMITTAL
DECORATIVE WOOD CASING TO
MATCH HISTORIC PROFILE -
STAINED
J1 A-506
TYP
E4
A-508
DASHED LINES INDICATE SITE WALLS
IN FRONT OF SECTION CUT
EXISTING GUTTER TO REMAIN
EXISTING GUTTER TO REMAIN
EQEQEQ EQ
A-508
J10
EXTERIOR LIGHT
FIXTURE - TYP
3' -6
1'-0"
ADA PUSH BUTTON 3
1"=1"
1" 2"
1/8"=1'-0"
4' 8' 16'
1"=100'-0"
100' 200'
1/16"=1'-0"
8' 16' 32'
1"=50'-0"
50' 100'
Smithsonian Facilities 600 Maryland Avenue S.W. Suite 5001
Washington, DC 20024-2520
Smithsonian Institution
KEY PLAN
GRAPHIC SCALE(S)
A
1 2 3 4 5 6 7 8 9 10 11 12
B
C
D
E
F
G
H
J
K
L
M
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
J
K
L
M
SHEET NO.
OF
PROJECT TITLE
A/E PROJECT NUMBER
ADDRESS
BUILDING NAME
PROJECT NUMBER
DRAWING TITLE
DRAWING TYPE
WORKING STAFF
STAMP
DATE
REVISION # DATE
SUBMISSION
REVISION DESCRIPTION
FOR
CONSTRUCTION
TYPE
DRAWN BY
SEQUENCEDISCIPLINE
CHECKED BYDESIGNED BY
:0 :2
A M
RENEW POLICE STATION,
REPLACE PUBLIC RESTROOMS
AND PAVILION, AND
ELECTRICAL SUBSTATION
POLICE - ELEVATIONS - NORTH AND
SOUTH
21445
ARCHITECTURAL
50 319
RENEW POLICE STATION, REPLACE
PUBLIC RESTROOMS AND PAVILION,
AND ELECTRICAL SUBSTATION
06/03/16
A
B Y
A p p ro ve r
F
IN
A L C O N S
TR
U C
TI
O N
D O C U M E N
TS
NZP
3001 Connecticut Avenue, NW Washington, DC
NZP
1633109
Cho Benn Holback + Associates
100 N. Charles St, Baltimore, MD 21201
CBH
1A
CBHCBH
2 01
FINAL CONSTRUCTION DOCUMENTS
SCALE = 1/8" = 1'-0"A-101 A-201
A1 SOUTH ELEVATION
SCALE = 1/8" = 1'-0"A-102 A-201
G1 NORTH ELEVATION
1 6/24/16 Addendum
Page 11 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 12 of 15
COPPER SILL FLASHING
WITH HEMMED EDGE-
SLOPED - SEAL TO
STONE5/8" PTD. GYP. BD.
6" 4 1/2"
LOUVER
1/2" CONT SEALANT
FLEXIBLE FLASHING -
TIE TO JAMB
FLASHING
PT WD BLOCKING -
TYPICAL
LOUVER
3 1/4"
EXIST EXTERIOR WALL
TO REMAIN
COPPER HEAD FLASHING
W/ HEMMED EDGE
SEALANT
CONT SEALANT -
TYPICAL
GWB - WHERE
OCCURS -
PAINTED
FLEXIBLE HEAD
FLASHING - TIE
TO JAMB
FLASHING
1 1/4" SCHEDULE 40 STL PIPE
GALVANIZED - PAINTED -
VERTICAL AND HORIZONTAL
RAILS
BLUESTONE COPING TO
CONCEAL STEEL
BASEPLATE WITH DRIP -
MORTAR TO EXISTING
CONCRETE SLAB
EXISTING STEEL BENT
PLATE AT EXISTING SLAB
EDGE
3' -6
2" 4"
4" 4"
4" 4"
4" 4"
4" 4"
4"
+/- 67'-0"
SEE CIVIL
GALV STEEL BASE PLATE
- ANCHOR TO EXISTING
CONCRETE SLAB - 1/2" X
4" X 4" WITH (4) 1/2"
DIAMETER ADHESIVE
ANCHORS
8" 4"
1 1/4" SCHEDULE 40 STL PIPE
GALVANIZED - PAINTED -
VERTICAL AND HORIZONTAL
RAILS
EXISTING CONCRETE
CURB
EXISTING STONE VENEER
RETAINING WALL
4" 4"
4" 4"
4" 4"
4" 4"
4" 4"
+/- 67'-0"
SEE CIVIL
CORE EXIST CONCRETE
AND SLEEVE POST - FULLY
GROUT SOLID
1 1/4" SCHEDULE 40 STL PIPE
GALVANIZED - PAINTED -
HANDRAIL - WELD BRACKET
TO VERTICAL POSTS
A-512
D10
SIM
MATCH EXIST
+/- 10" VIF
BLUESTONE COPING
ALIGN JOINT IN STONE
WITH CENTERLINE
HANDRAIL
EDGE OF EXISTING
SLAB BELOW
GUARDRAIL BASE
PLATE BELOW
COPING
J7 A-507
8"
23A 9A
DECORATIVE COPPER
TRIM - BACKWRAP -
EXTEND TO SEALANT
SLOPED COPPER
SILL FLASHING WITH
HEMMED EDGE -
EXTEND TO PRIMARY
SEALANT
1/2" GALV
STL EMBED
PLATE -
CONTINUOUS
CONT GALV STL
ANGLE - SEE
STRUCTURAL
DRAWINGS
PT WD BLOCKING
- TYP
FIBERGLASS
THERMAL
SPACER
AIR BARRIER
FLEXIBLE
FLASHING -
LAP OVER
AIR BARRIER
4" MIN
2"
ALUMINUM
CURTAINWALL
SYSTEM - ANCHOR
TO EMBED PLATE
CONT 1/2"
SEALANT
CONT INTERIOR
SEALANT AND BACKER
ROD - ENTIRE
PERIMETER - TYP
CONT PRIMARY
SEALANT AND BACKER
ROD - ENTIRE
PERIMETER - TYP
CONT SECONDARY
WEATHER SEAL -
PROPERLY WEEPED
AND LOCATED
BEHIND
CURTAINWALL
WEEPS
4" MIN
3/4" 2"
1 1/2"
TPO MEMBRANE
FLEXIBLE FLASHING -
LAP 4" MIN - WELD TO
TPO MEMBRANE
COPPER APRON - LAP
4" ONTO ROOF MIN
COPPER GUTTER
WITH INTERNAL LINER
COPPER FASCIA WITH
CONTINUOUS EDGE
STRIP AND DRIP
HIGH TEMPERATURE
ICE AND WATER
SHIELD - LAP UNDER
COPPER APRON 4" MIN
CONTINUOUS CLEAT
1/4" MAX GAP
COPPER SOFFIT
EXTEND HIGH
TEMPERATURE ICE
AND WATER SHIELD
TO PRIMARY SEALANT
FLEXIBLE HEAD
FLASHING - TIE TO
JAMB FLASHING
DECORATIVE COPPER
TRIM - BACKWRAPPED
1/2" SEALANT
LIGHT GAUGE CLIP
ANGLE - BOTH SIDES
OF FRT WOOD
BLOCKING
INTERIOR SEALANT AND
BACKER ROD - ENTIRE
PERIMETER - TYP
PRIMARY SEALANT
AND BACKER ROD -
ENTIRE PERIMETER -
TYPSECONDARY SEALANT
AND BACKER ROD -
ENTIRE PERIMETER -
TYP
F&T ANCHOR - SECURE
TO WD BLOCKING
1"=1"
1" 2"
1/8"=1'-0"
4' 8' 16'
1"=100'-0"
100' 200'
1/16"=1'-0"
8' 16' 32'
1"=50'-0"
50' 100'
Smithsonian Facilities 600 Maryland Avenue S.W. Suite 5001
Washington, DC 20024-2520
Smithsonian Institution
KEY PLAN
GRAPHIC SCALE(S)
A
1 2 3 4 5 6 7 8 9 10 11 12
B
C
D
E
F
G
H
J
K
L
M
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
J
K
L
M
SHEET NO.
OF
PROJECT TITLE
A/E PROJECT NUMBER
ADDRESS
BUILDING NAME
PROJECT NUMBER
DRAWING TITLE
DRAWING TYPE
WORKING STAFF
STAMP
DATE
REVISION # DATE
SUBMISSION
REVISION DESCRIPTION
FOR
CONSTRUCTION
TYPE
DRAWN BY
SEQUENCEDISCIPLINE
CHECKED BYDESIGNED BY
:0 :2
A M
RENEW POLICE STATION,
REPLACE PUBLIC RESTROOMS
AND PAVILION, AND
ELECTRICAL SUBSTATION
POLICE - EXTERIOR DETAILS
21445
ARCHITECTURAL
65 319
RENEW POLICE STATION, REPLACE
PUBLIC RESTROOMS AND PAVILION,
AND ELECTRICAL SUBSTATION
A
B Y
A p p ro ve r
F
IN
A L C O N S
TR
U C
TI
O N
D O C U M E N
TS
NZP
3001 Connecticut Avenue, NW Washington, DC
NZP
1633109
Cho Benn Holback + Associates
100 N. Charles St, Baltimore, MD 21201
CBH
1A
CBHCBH
5 07
06/03/16 FINAL CONSTRUCTION DOCUMENTS
SCALE = 1 1/2" = 1'-0"A-507
E10 DETAIL - SECTION - LOUVER SILL
SCALE = 1 1/2" = 1'-0"A-608 A-507
J10 DETAIL - SECTION - HEAD
SCALE = 1" = 1'-0"A-404 A-507
J7 DETAIL - GUARDRAIL
SCALE = 1" = 1'-0"A-404 A-507
E7 DETAIL - GUARDRAIL AT RAMP
SCALE = 3" = 1'-0"A-404 A-507
A11 DETAIL - PLAN
SCALE = 3" = 1'-0"A-312 A-507
A1 DETAIL - SECTION
SCALE = 3" = 1'-0"A-504 A-507
A7 DETAIL - SECTION
1 6/24/16 Addendum 3 7/12/16 Addendum
Page 12 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 13 of 15
X3
6"2 1/2"1"
AIR BARRIER - EXTEND INTO
CAVITY AS FAR AS POSSIBLE
FLEXIBLE JAMB FLASHING -
LAP OVER AIR BARRIER 4"
MIN - TIE TO HEAD AND SILL
FLASHING
PT WD BLOCKING
PATCH AND REPAIR
EXISTING PLASTER AT
DEMOLISHED
STOREFRONT WINDOW
CONT INTERIOR SEALANT
AND BACKER ROD - ENTIRE
PERIMETER - TYP
CONT PRIMARY SEALANT
AND BACKER ROD - ENTIRE
PERIMETER - TYP
CONT SECONDARY
SEALANT AND BACKER
ROD - ENTIRE PERIMETER -
TYP
EXTRUDED
ALUM TRIM BY
CURTAINWALL
MANUF - 2 1/2"
X 2 3/4"
1/2" SEALANT
PT WD SHIM
EXISTING
STONE SILL TO
REMAIN
1/2"
3"10 1/2"8"1/2"
1"8 1/2"1"3 1/
2" 6"
1/
2"
1"
1/ 2"
1/
2"
5/
8"
4"
3"1'-4" VIF
3/4" VIF
1 5/8"
DECORATIVE WD
SURROUND TO MATCH
HISTORIC PROFILE -
STAINED
ALUM CURTAINWALL
ENTRANCE SYSTEM
SECONDARY SEALANT
AND BACKER ROD -
ENTIRE PERIMETER - TYP
PRIMARY SEALANT AND
BACKER ROD - ENTIRE
PERIMETER - TYP
INTERIOR SEALANT AND
BACKER ROD - ENTIRE
PERIMETER - TYP
PATCH AND REPAIR
EXIST PLASTER FINISH AT
DEMOLISHED
STOREFRONT
EXTERIOR SHEATHING
FLEXIBLE JAMB FLASHING -
TIE TO HEAD FLASHING
AIR BARRIER - LAP OVER
FLEXIBLE FLASHING 4" MIN
PT (2) 2X4 WD STUDS AT
DOOR JAMB
EXISTING STONE SILL
EXISTING FACE OF WALL
BELOW
5/8" GWB ON PT WD
BLOCKING
ALIGN
FLEXIBLE JAMB FLASHING -
TIE TO HEAD AND SILL
FLASHING
EXISTING WD POST
PT WD BLOCKING
FILL CAVITY WITH MINERAL
WOOL INSULATION
ALUMINUM COVER BY
CURTAINWALL MANUF
FASTEN ALUM COVER TO
WD BLOCKING
A-508
A7
XA
X3
13C 9E
A
LI
G
N PATCH AND
REPAIR EXISTING
PLASTER
1" 3'
/2
V
IF
1/
2" 2'
S E
E W
IN
D
O W
S C
H E
D
FACE OF EXISTING
PLASTER BELOW -
PATCH AND REPAIR
AS REQUIRED
EDGE OF SOLID
SURFACE STOOL
ALUMINUM
CURTAINWALL
SYSTEM - TYP
EXTRUDED ALUM TRIM
BY CURTAINWALL
MANUF - MATCH
CURTAINWALL FINISH -
2 1/2" X 2 3/4"
2 1/2"
8"1"
2 1/2"
1/ 2"
T Y
P
1/
2"
8"
8' - 8" VIF
1'-9" VIF1'-4" VIF
VIF
3/4"
1 5/8"
1/2"1/2" 8"
1/
2"
1/2"1"8 1/2"1"
EDGE OF EXISTING
STONE SILL - VIF
1"
1/
2"
INSULATED ALUMINUM
CORNER COVER BY
CURTAINWALL
MANUFACTURER
EDGE OF EXISTING
STONE SILL - VIF
ALIGN
5/8" GWB - PAINTED
PT WD BLOCKING - TYP
EXISTING CMU PIER
WITH PLASTER FINISH
DECORATIVE WOOD
SURROUND TO MATCH
HISTORIC PROFILE -
STAINED
ALUMINUM COVER BY
CURTAINWALL
MANUFACTURER - FASTEN
TO WD BLOCKING
FLEXIBLE JAMB
FLASHING - TIE TO
HEAD AND SILL
FLASHING
PT WD BLOCKING -
TYPICAL
A-508
A1
A-508
J7
1/ 2"
V
IF 1/2" VIF
EXISTING WD POST - VIF VIF
1 3/4"
EXISTING WD POST - VIF
Roof Bearing 92'-0"
+9' - 2 3/4"
FACE OF METAL
PANEL BEYOND
VIF
1 3/8" 6" 2 1/2"
/2
1/
4"
REMOVE AND
REPLACE EXISTING
COPPER FASCIA AND
SOFFIT
EXISTING JOIST
HANGER
ALUMINUM CURTAINWALL
SYSTEM - ANCHOR TO
STEEL FLAT PLATE
CONT SEALANT - TYP
FLEXIBLE HEAD
FLASHING - TIE TO
JAMB FLASHING
COPPER HEAD
FLASHING WITH
HEMMED EDGE
DECORATIVE WOOD
SURROUND TO
MATCH HISTORIC
PROFILE - STAINED
5/8" GWB - PAINTED
AIR BARRIER - LAP OVER
FLEXIBLE FLASHING
EXISTING WD
HEADER
CONT GALV STEEL FLAT
PLATE 4 1/2" X 1/4" AT
CURTAINWALL ANCHOR
LOCATIONS - ANCHOR TO
EXISTING WD HEADER
WITH 1/4" LAG BOLTS AT
12" OC
A-508
E7
/4
3/
4"
+7' - 4"
ALUMINUM HEADER TO
CONCEAL ADA
OPERATOR - BY
CURTAINWALL MANUF
1 1 5/8"
2 1/2"
9 1/4" VIF
4 1/2" VIF
/2
1/
4"
1' -0
/4
V
IF
+9 - 2 3/4"
EXISTING WD
HEADER
EXISTING WD
HEADER
5/8" GWB -
PAINTED
CONT INTERIOR AIR
SEALANT AND
BACKER ROD -
ENTIRE PERIMETER
- TYP
COPPER HEAD FLASHING
WITH HEMMED EDGE -
EXTEND BEYOND
PRIMARY SEAL
CONT PRIMARY SEALANT
AND BACKER ROD -
ENTIRE PERIMETER - TYP
CONT SECONDARY
SEALANT AND BACKER
ROD - ENTIRE
PERIMETER - TYP
FLEXIBLE HEAD
FLASHING - TIE TO JAMB
FLASHING - EXTEND 4"
MIN
AIR BARRIER - LAP OVER
FLEXIBLE HEAD
FLASHING 4" MIN
FLEXIBLE CORNER
FLASHING - LAP OVER
AIR BARRIER 4" MIN
REMOVE AND REPLACE
EXISTING COPPER
FASCIA AND SOFFIT WITH
DRIP
EXTERIOR
SHEATHING
1/2" SEALANT AND
BACKER ROD
DECORATIVE
WOOD
SURROUND TO
MATCH HISTORIC
PROFILE -
STAINED
1" 1"
A-508
A7
Upper Level 82'-0"
E4 A-508
A1 A-508
1"8 1/2"1"
11"3'-5"11"
/2
1/2"10 1/2" 1/2" 10 1/2"
1"
1/ 2"
1"
6"
1/2"7 1/2"1/2"
BEVELED WD
SURROUND
EXISTING
STONE SILL
EXISTING
STONE VENEER
WD TRIM
WD TRIM BASE
1/2" SEALANT
CURTAIN WALL
ENTRANCE
FRAME
3' -6
ADA PUSH
BUTTON
ACTUATOR
EQEQ
ALUMINUM COVER
BY CURTAINWALL
MANUFACTURER -
TYPICAL BOTH
SIDES OF DOOR
5/
8"
1"1/2"3 3/4"3 3/4"1/2"1"
1/ 2"
1/ 4"
BEVELED WD SURROUND -
STAINED
WD BASE TRIM BEYOND -
STAINED
WD TRIM - STAINED - TYP
1"=1"
1" 2"
1/8"=1'-0"
4' 8' 16'
1"=100'-0"
100' 200'
1/16"=1'-0"
8' 16' 32'
1"=50'-0"
50' 100'
Smithsonian Facilities 600 Maryland Avenue S.W. Suite 5001
Washington, DC 20024-2520
Smithsonian Institution
KEY PLAN
GRAPHIC SCALE(S)
A
1 2 3 4 5 6 7 8 9 10 11 12
B
C
D
E
F
G
H
J
K
L
M
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
J
K
L
M
SHEET NO.
OF
PROJECT TITLE
A/E PROJECT NUMBER
ADDRESS
BUILDING NAME
PROJECT NUMBER
DRAWING TITLE
DRAWING TYPE
WORKING STAFF
STAMP
DATE
REVISION # DATE
SUBMISSION
REVISION DESCRIPTION
FOR
CONSTRUCTION
TYPE
DRAWN BY
SEQUENCEDISCIPLINE
CHECKED BYDESIGNED BY
:0 :2
A M
RENEW POLICE STATION,
REPLACE PUBLIC RESTROOMS
AND PAVILION, AND
ELECTRICAL SUBSTATION
POLICE - EXTERIOR DETAILS
21445
ARCHITECTURAL
66 319
RENEW POLICE STATION, REPLACE
PUBLIC RESTROOMS AND PAVILION,
AND ELECTRICAL SUBSTATION
06/03/16
A
B Y
A p p ro ve r
F
IN
A L C O N S
TR
U C
TI
O N
D O C U M E N
TS
NZP
3001 Connecticut Avenue, NW Washington, DC
NZP
1633109
Cho Benn Holback + Associates
100 N. Charles St, Baltimore, MD 21201
CBH
1A
CBHCBH
5 08
FINAL CONSTRUCTION DOCUMENTS
SCALE = 3" = 1'-0"A-508 A-508
J7 DETAIL - PLAN
SCALE = 3" = 1'-0"A-508 A-508
A1 DETAIL - PLAN
SCALE = 1 1/2" = 1'-0"A-102 A-508
E1 DETAIL - PLAN - LOBBY 200
SCALE = 1 1/2" = 1'-0"A-112 A-508
E4 DETAIL - HEAD - ENTRANCE
SCALE = 3" = 1'-0"A-508 A-508
E7 DETAIL - SECTION
SCALE = 1/2" = 1'-0"A-201 A-508
J10 ENL ELEV - ENTRANCE DOOR
SCALE = 6" = 1'-0"A-508 A-508
A7 DETAIL - PLAN - WD SURROUND
1 6/24/16 Addendum
Page 13 of 14 Date 07.13.2016
F16SOL10044 Amendment 000005 - 07/14/2016 - Page 14 of 15
SEE LANDSCAPE DRAWINGS
+/- 10"
4" 6"
LOUVER
CONT SEALANT
COPPER THRU WALL
FLASHING WITH HEMMED
EDGE
CONT GALV STEEL ANGLE
FLEXIBLE FLASHING -
LAP OVER COPPER
FLASHING 4" MIN
SITE BARRIER WALL -
SEE LANDSCAPE
DRAWINGS
GROUT SOLID
WEEP AT 24" O.C.
FLEXIBLE HEAD
FLASHING - TIE TO
JAMB FLASHING
SITE BARRIER WALL
- SEE LANDSCAPE
DRAWINGS
FLEXIBLE JAMB
FLASHING - TIE TO
SILL AND HEAD
FLASHING
CONT SEALANT -
TYP
RETURN STONE TO
CLOSE JAMB
LOUVER
PT WD BLOCKING
4" 6"
9E
SEE LANDSCAPE DRAWINGS
+/- 10"
HM DOOR FRAME
CONT SEALANT
COPPER THRU WALL
FLASHING WITH HEMMED
EDGE
CONT GALV STEEL ANGLE
FLEXIBLE FLASHING
- LAP OVER COPPER
FLASHING 4" MIN
SITE BARRIER WALL -
SEE LANDSCAPE
DRAWINGS
GROUT SOLID
WEEP AT 24" O.C.
FLEXIBLE HEAD
FLASHING - TIE TO
JAMB FLASHING
9E
1C 1D
FLEXIBLE JAMB
FLASHING - TIE TO
HEAD FLASHING - TYP
CONT SEALANT - TYP
RETURN STONE TO
CLOSE JAMB - TYP
SITE BARRIER WALL -
SEE LANDSCAPE
DRAWINGS
HM DOOR FRAME
HM DOOR FRAME
CONT SEALANT - TYP
PT WD BLOCKING
LOUVER - ANCHOR
TO HM FRAME ON
JAMBS
COMPRESSIBLE FILL
M A
T C
H W
A
LL
T H
K
S E
E L
A N
D S
C A
P E
D W
G S
0"
FLEXIBLE JAMB
FLASHING - TIE TO
HEAD FLASHING - TYP
CONT SEALANT - TYP
RETURN STONE TO
CLOSE JAMB - TYP
HM DOOR FRAME
LOUVER FRAME -
ANCHOR TO HM
FRAME ON JAMBS
F2B
CONT SEALANT - TYP
COPPER THRU WALL
FLASHING WITH HEMMED
EDGE
CONT GALV STEEL ANGLE
FLEXIBLE FLASHING -
LAP OVER COPPER
FLASHING
SITE BARRIER WALL -
SEE LANDSCAPE
DRAWINGS
GROUT SOLID
WEEP AT 24" O.C.
HM DOOR FRAME - MATCH WALL
THICKNESS
FLEXIBLE HEAD FLASHING -
TIE TO JAMB FLASHING
MATCH WALL THK
+/- 10"
LOUVER
6"
COPPER SILL FLASHING - SLOPED -
WITH HEMMED EDGE
8"
FORMED JOINT FILLER
PAVER ON SETTING BED
FLEXIBLE FLASHING
1/
2"
SEALANT
TAPE
1/2" SEALANT
COPPER SILL FLASHING - TURN UP IN
BACK OF HM FRAME
HM FRAME -
PAINTED
4"
ROOF BEARING
79' - 0"
UPPER FLOOR
68' - 0"
EQEQ
COPPER DOWNSPOUT WITH STRAP
HANGERS WHERE REQUIRED
EQEQ
ALIGN WITH CENTERLINE
METAL PANEL
ALIGN WITH CENTERLINE
STAIR TREAD
RECTANGULAR CAST
IRON BOOT
DOWNSPOUT BELOW
GRADE
MECHANICAL VAULT
CONCRETE WALL
CONCRETE STAIR
EQ
EQ
MATCH SLOPE OF
DOWNSPOUT TO SLOPE
OF STAIR
A-A
A-A
ENLARGED PLAN AT DOWNSPOUT HANGER
STRUCTURE
COPPER
DOWNSPOUT
HANGER
COPPER
DOWNSPOUT
COPPER
FASTENER - TYP
STAINLESS STEEL POST TUBE
6" X 4" X 1/4" - REMOVABLE
1/4" STAINLESS STEEL PLATE,
WELD AND GRIND SMOOTH 1/4" STAINLESS STEEL PLATE,
WELD AND GRIND SMOOTH
STAINLESS STEEL POST TUBE
6" X 4" X 1/4" - REMOVABLE
CONCRETE SLAB
PAVERS - SEE
LANDSCAPE DRAWINGS PAVERS - SEE
LANDSCAPE
DRAWINGS
AUTO DOOR
OPENER ACTIVATION BUTTON -
RECESSED
DATA & POWER CONDUIT -
PROVIDE CONNECTOR AND 24"
MIN COILED CABLE TO ALLOW
FOR REMOVAL OF BOLLARD
1/2" BACKER ROD AND
SEALANT - TYP
CONCRETE SLAB
AUTO DOOR OPENER
ACTIVATION BUTTON -
RECESSED
1/2" BACKER ROD AND SEALANT - TYP
A-A
A-A PLAN DETAIL - ADA BOLLARD
SECTION DETAIL - ADA BOLLARD SECTION DETAIL - ADA BOLLARD
3" 3"4"
STAINLESS STEEL TUBE SLEEVE
WITH STAINLESS STEEL PLATE
CAP AT BOTTOM
1" LONG WELD AT FOUR POINTS
TO SECURE POST TO SLEEVE
DATA & POWER CONDUIT -
PROVIDE CONNECTOR AND 24"
MIN COILED CABLE TO ALLOW
FOR REMOVAL OF BOLLARD
1" LONG WELD AT FOUR POINTS
TO SECURE POST TO SLEEVE
STAINLESS STEEL TUBE SLEEVE
WITH STAINLESS STEEL PLATE
CAP AT BOTTOM
3" 5"
4"
2" 4"
3'
3'
FLASHING - TYPICAL
MEMBRANE WITH
PROTECTION BOARD
3'
B-B
ENLARGED DETAIL - ADA BOLLARDB-B
3" = 1'-0"3" = 1'-0"
1" = 1'-0" 1" = 1'-0"
MEMBRANE WITH
PROTECTION
BOARD
FLASHING -
TYPICAL
2" 4"
C
8" 6"
1/
2"
COMPRESSIBLE FILL
GWB - PAINTED
1B
COPPER SILL BELOW
ALUMINUM
CURTAINWALL SYSTEM
2" DEEP LOUVER
WITH GLAZING
FRAME
COPPER SILL FLASHING
- SLOPED - EXTEND
BELOW WD BLOCKING
HEMMED EDGE
5/8" PTD. GYP. BD.
LOUVER
1/2" CONT SEALANT
FLEXIBLE SILL FLASHING -
TIE TO JAMB FLASHING
1/2" PT WD BLOCKING
SEALANT
4" 6"
1/2" DIA X 2"
STAINLESS STEEL
STUD WELDED TO
STAINLESS STEEL
SLEEVE - ON EACH
SIDE OF TUBE -
TYPICAL
PAVERS - SEE
LANDSCAPE
DRAWINGS
1/2" BACKER ROD
AND SEALANT -
TYP
1/4" THICK
STAINLESS STEEL
TUBE SLEEVE WITH
TIGHT FIT TO
BOLLARD - 1/4"
STAINLESS STEEL
PLATE CAP AT
BOTTOM
1" LONG WELD AT
FOUR POINTS TO
SECURE POST TO
SLEEVE
5" 4"
COORDINATE
PENETRATION IN
STEEL SLEEVE AND
POST FOR
CONDUIT - ROUTE
CONDUIT IN SLAB
FLASHING
MEMBRANE WITH
PROTECTION
BOARD
STAINLESS
STEEL
DRAWBAND
1/
2"
STAINLESS STEEL 6" X 4" X
1/4" TUBE
AUTO DOOR OPENER
ACTIVATION BUTTON -
RECESSED
3" 3"
4"
STAINLESS STEEL TUBE
SLEEVE WITH STAINLESS
STEEL PLATE CAP AT
BOTTOM
1"=1"
1" 2"
1/4"=1'-0"
2' 4' 8'
1/8"=1'-0"
4' 8' 16'
1/16"=1'-0"
8' 16' 32'
TRUE NORTH
1"=50'-0"
50' 100'
Smithsonian Facilities 600 Maryland Avenue S.W. Suite 5001
Washington, DC 20024-2520
Smithsonian Institution
KEY PLAN
GRAPHIC SCALE(S)
A
1 2 3 4 5 6 7 8 9 10 11 12
B
C
D
E
F
G
H
J
K
L
M
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
J
K
L
M
SHEET NO.
OF
PROJECT TITLE
A/E PROJECT NUMBER
ADDRESS
BUILDING NAME
PROJECT NUMBER
DRAWING TITLE
DRAWING TYPE
WORKING STAFF
STAMP
DATE
REVISION # DATE
SUBMISSION
REVISION DESCRIPTION
PROJECT NORTH
FOR
CONSTRUCTION
TYPE
DRAWN BY
SEQUENCEDISCIPLINE
CHECKED BYDESIGNED BY
:3 :1
A M
RENEW POLICE STATION,
REPLACE PUBLIC RESTROOMS
AND PAVILION, AND
ELECTRICAL SUBSTATION
RESTROOMS - EXTERIOR SECTION
DETAILS
21445
ARCHITECTURAL
234 319
RENEW POLICE STATION, REPLACE
PUBLIC RESTROOMS AND PAVILION,
AND ELECTRICAL SUBSTATION
06/03/16 FINAL CONSTRUCTION DOCUMENTS
A
B Y
A p p ro ve r
F
IN
A L C O N S
TR
U C
TI
O N
D O C U M E N
TS
NZP
3001 Connecticut Avenue, NW Washington, DC 20008
NZP
1633109
CHO BENN HOLBACK + ASSOCIATES
100 N. CHARLES ST, BALITMORE, MD 21201
CBH
2A
CBHCBH
5 05 1 1/2" = 1'-0"A-505
A7 DETAIL - SECTION - LOUVER HEAD
1 1/2" = 1'-0"A-505
A10 DETAIL - SECTION - LOUVER JAMB
1 1/2" = 1'-0"A-505
J7 DETAIL - SECTION - HM DOOR HEAD
1 1/2" = 1'-0"A-505
A1 DETAIL - SECTION - HM DOOR JAMB
1 1/2" = 1'-0"A-505
E7 DETAIL - SECTION - LOUVER
1/2" = 1'-0"A-505
E10 DETAIL - ELEVATION - DOWNSPOUT
1" = 1'-0"A-505
E1 ADA SECURITY BOLLARD
1 1/2" = 1'-0"A-505
D4 DETAIL - PLAN
1 1/2" = 1'-0"A-505
D1 DETAIL - SECTION - LOUVER SILL
3 07/12/16 Addendum
Page 14 of 14 Date 07.13.2016