Exhibit A- Technical Evaluation - Subfactor 1.docx
DOCX document 18 KB Posted
- Attached to
- Construct C-130 Flight Simulator Training Facility Federal contract opportunity
- Solicitation number
- W50S8J-22-R-0002
About this file
This document contains an exhibit for a technical evaluation of a federal solicitation to construct a C-130 flight simulator training facility. The solicitation is seeking a contractor to demonstrate experience with unique site conditions like stormwater pollution prevention and construction within an active airfield, as well as experience building an industrial structure over 10,000 square feet constructed as three separate enveloped sections with controlled HVAC systems and a highbay area capable of supporting heavy equipment like a flight simulator. Relevant electrical experience must include installing underground high voltage lines up to 650 feet and a 500kVA medium voltage transformer, as well as provision of an emergency standby power system. Security experience with intrusion detection, access control systems, and ICD-705 compliant wall and ceiling construction is also required. Offerors must submit details on three most relevant past projects within the last five years using the provided template, not exceeding six pages per project. A combined site visit and pre-proposal conference is scheduled for July 6, 2022.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 05.pdf | ||
| ATTACHMENT 4 _ SOLICITATION RFI RESPONSES_UPDATED 15 Aug 22 (20 PAGES).pdf | ||
| Amendment 04.pdf | ||
| Amendment 03.pdf | ||
| ATTACHMENT 4 _ SOLICITATION RFI RESPONSES (11 PAGES).pdf | ||
| Amendment 02.pdf | ||
| Amendment 01.pdf | ||
| Construct C-130 Flight Sim_PreProposal Conference Slides.pptx | PPTX presentation | |
| Pre-Proposal Site Visit Minutes.pdf | ||
| Site Visit Sign In Sheet.pdf | ||
| SPECS Vol 1.pdf | ||
| SPECS Vol 2.pdf | ||
| Exhibits B and C - Past Peformance Reference Questionnaire.docx | DOCX document | |
| W50S8J-22-R-0002 SAM.pdf | ||
| DRAWINGS.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXHIBIT A
Technical Evaluation - Subfactor 1 Worksheet General Construction and Renovation Experience This form shall be submitted by each offeror, outlining the three (3) most relevant contracts (Government or Commercial) which are currently in performance or have been completed by the offeror within the past five (5) year period. Submit one (1) form per project; Limit page count to six (6) pages per project, to include Part 1: Project Information.
The intent of this information is to give the Government insight into the offerors experience managing multi-discipline construction projects, focusing on the relevance and extent that contracts submitted for review are similar in size, scope and complexity to the work anticipated under this project.
The offeror shall fill in PARTS 1 & 2 below for each project submitted. Part 2 shall include a brief narrative relating the size, scope and complexity of the identified project to each Key Point. If the scope of an identified project does not include one or more of the Key Points, the offeror shall insert “N/A”. Offerors are cautioned that projects submitted for review which contain relevant experience with more (or all) of the Key Points listed above will be evaluated more favorably than projects that contain less (or none) of the Key Points.
PART 1 – PROJECT INFORMATION
Contract Number:
Project Title:
Date of Award:
Period of Performance (Days)
Project Completion Date:
Project Location:
| Dollar Value (Original/ Final): |
| $ / $ |
Brief Description of Project:
Your role in referenced contract (Prime/ Sub):
PART 2 – EXPERIENCE NARRATIVE
KEY POINT 1: Unique Site Conditions – For this Key Point, the Government is seeking relevant experience which demonstrates the following: 1) Experience managing a construction site regulated by NYSDEC Storm water Pollution Prevention Plan along with installation of engineered storm water structures; 2) Experience with construction projects within or contiguous to an active Government airfield.
Note: Contractors may tailor the amount of space provided for each Key Point and are not limited to the space provided. With that said, the total page count for each Exhibit A shall not exceed six (6) pages (to include Part 1, Project Information. [Contractors shall delete this note prior to submission] KEY POINT 2: Specific Building Requirement – For this Key Point, the Government is seeking relevant experience which demonstrates the following: 1) Construction of a >10,000s/f industrial/business structure (Type II-B Construction); 2) Air Barrier Separate – 3 separate enveloped sections/ controlled HVAC Systems; 3) Highbay area with thickened slab capable of supporting heavy equipment (similar to a full motion C-130 flight simulator); 4) Bridge crane installation.
KEY POINT 3: Specific Electrical Requirements - For this Key Point, the Government is seeking relevant experience which demonstrates the following: 1) Underground High Voltage Line Installation (650’ distance in connection to overhead utility line); 2) Transformer Installation (13.2kV-480/277V, 3 Phase, 500kVA medium voltage stepdown transformer); 3) Provision / Installation of appropriately sized Emergency Standby Power System.
KEY POINT 4: Security Requirements - For this Key Point, the Government is seeking relevant experience which demonstrates the following: 1) Intrusion Detection and Access Control Systems; 2) ICD-705 Compliant Wall and Concrete Ceiling Lid Construction / Soundproofing.