Exhibit 2 Parkdale MS Lenel and Alarm Drawings REVISED.pdf

PDF 6 MB Posted

Attached to
ESB - ODOT Parkdale MS Lenel Card Reader Access & Intrusion Alarm Security
Solicitation number
S-73000-00013213
Issued by
Hood River County, Oregon

About this file

The document is a detailed site plan and floor plan exhibit (Exhibit 2) from the Oregon Department of Transportation (ODOT) for the Parkdale Maintenance Station, specifically outlining security system installation requirements. The exhibit provides comprehensive drawings for installing card readers and security alarm systems across three buildings: the Maintenance Shop, Storage Building, and Fuel Station. The project involves installing four card readers at the maintenance shop, two card readers and security alarm keypads on exterior personnel doors, and one card reader and security alarm system at the fuel station. The plans include multiple bid items and alternate options, such as installing card readers in specific locations like Office 101, Maintenance Bay 104, and a mezzanine storage area, with existing electrical conduits between buildings to be utilized for networking and security system connections.

The procurement is exclusively reserved for certified Emerging Small Businesses (ESB) registered with Oregon's Certification Office for Business Inclusion and Diversity (COBID), with contractors required to perform at least 51% of labor using their own workforce. The project necessitates that all Lenel-specific equipment be purchased from a Lenel Value Added Reseller (VAR), with programming and testing performed by a certified Lenel installer. Security alarm systems will be monitored by an ODOT-appointed firm after project completion. While no specific budget is detailed in the exhibit, the project involves comprehensive security infrastructure upgrades, including electric strikes, door handles, surface closers, motion detectors, and alarm panels across multiple buildings at the Parkdale Maintenance Station located at 7285 Highway 35, Mt. Hood, Oregon.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INSTALL FOUR (4) CARD

READERS AT MAINTENANCE

SHOP BUILDING.INSTALL

SECURITY ALARM SYSTEMS BY

TWO (2) EXTERIOR PERSONNEL

DOORS.

INSTALL TWO (2) READERS AND

TWO (2) SECURITY ALARM

KEYPADS ON EXTERIOR

PERSONNEL DOORS.

INSTALL ONE (1) CARD

READER AND ONE (1)

SECURITY ALARM SYSTEM AT

FUEL STATION BULDING.

EXISTING ELECTRICAL

CONDUIT BETWEEN

MAINTENANCE SHOP AND

STORAGE BUILDING.

03/27/2025

EXISTING ELECTRICAL

CONDUIT BETWEEN

MAINTENANCE SHOP AND

FUEL BUILDING.APPROX

LOCATION OF ELECTRICAL

VAULT BETWEEN BOTH

BUILDINGS.

Revised 3/27/2025 Exhibit 2 Parkdale MS Lenel and Alarm Drawings Revised 1/4

ADD ALTERNATE: #1

ROOM ON MEZZANINE

ON THIS AREA.

REPLACE EXISTING

METAL DOOR WITH

SOLID CORE WOOD

DOOR AND INSTALL ALL

DOOR HARDWARE

LISTED ON

SPECIFICATIONS AND

INSTALL ONE (1) CARD

READER. INSTALL

DOOR FRAME.

INSTALL CARD

READERS AND

SECURITY ALARM

KEYPADS BY TWO (2)

PERSONNEL DOORS.

EXISTING

ELECTRICAL PANEL

APPROX. AREA.

NETWORK AREA.

COORDINATE

WITH CPM EXACT

LOCATION FOR

LENEL PANEL.

INSTALL CARD

READER BY THE

SIDE ENTRANCE OF

OFFICE 101.

EXISTING CONDUIT

TO STORAGE

BUILDING IN THIS

AREA.

03/27/2025

BID ITEM #1:

ALL LENEL AND SECURITY ALARM HARDWARE TO BE

INSTALLED INSIDE THE STORAGE AREA 103 AND ALL

WORK REQUIRED TO INSTALL TWO (2) CARD

READERS AT DOORS IN OFFICE 101 AND ONE (1)

CARD READER AT MAINTENANCE BAY 104 EXTERIOR

DOOR. TWO (2) INTRUSION ALARM SYSTEMS BY

MAINTENANCE BAY 104 AND OFFICE 101 EXTERIOR

DOORS.

ADD. ALTERNATE #1

ALL WORK REQUIRED TO REPLACE EXISTING DOOR

WITH SOLID CODE WOOD DOOR AND TO INSTALL A

CARD READER AT DOOR ON STORAGE AREA ON

MEZZANINE ABOVE STORAGE ROOM 109.

VAULT WITH

EXISTING CONDUIT

TO FUEL BUILDING

ALSO IN THIS AREA.

Revised 3/27/2025 Exhibit 2 Parkdale MS Lenel and Alarm Drawings Revised 2/4

INSTALL CARD READERS

AND SECURITY ALARM

SYSTEMS BY TWO (2)

EXISTING PERSONNEL

DOORS.

ELECTRICAL PANEL

AND EXISTING

CONDUIT FROM

MAINTENANCE

BUILDING IN THIS

AREA.

03/27/2025

ADD. ALTERNATE #2

INSTALL TWO (2) CARD READERS AND TWO (2)

SECURITY ALARM SYSTEMS BY EXTERIOR DOORS

AT THIS BUILDING. ALL DOOR AND NETWORK

HARDWARE AT THIS BUILDING AND ALL WIRING IN

ORDER TO BRING LENEL NETWORK AND

INSTRUSION ALARM SECURITY TO THIS BUILDING.

Revised 3/27/2025 Exhibit 2 Parkdale MS Lenel and Alarm Drawings Revised 3/4

03/27/2025

ELECTRICAL PANEL

IN THIS AREA.

VAULT WITH

CONDUIT FROM

MAINTENANCE SHOP

BUILDING IN THIS

AREA.

INSTALL CARD READERS

AND SECURITY ALARM

SYSTEMS BY EXISTING

PERSONNEL DOOR.

BID ITEM #2

INSTALL ONE (1) CARD READER AND ONE (1)

SECURITY ALARM SYSTEMS BY NORTH EXTERIOR

DOOR AT THIS BUILDING. ALL DOOR AND NETWORK

HARDWARE AT THIS BUILDING AND ALL WIRING IN

ORDER TO BRING LENEL NETWORK AND INTRUSION

ALARM SECURITY TO THIS BUILDING.

Revised 3/27/2025 Exhibit 2 Parkdale MS Lenel and Alarm Drawings Revised 4/4