Exhibit 006 - Cash Pak Holes.pdf
PDF 225 KB Posted
- Attached to
- Cash PAK System Federal contract opportunity
- Solicitation number
- 2031ZA23R00015
About this file
This government file provides specifications for air escape holes in cash pak systems. The document outlines requirements for hole diameter, which must be no larger than 6.35mm, or 1/4 inch. Hole placement is also specified, with a minimum spacing of 8.5 inches between holes and defined vertical and horizontal positioning.
The related federal contract opportunity is a solicitation issued by the Department of the Treasury Bureau of Engraving and Printing seeking proposals for a cash pak system. Details include the solicitation number, brief product description, and issuing agency. Proposers are advised to carefully review specifications for air hole requirements in manufacturing cash paks.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cash Pak Holes
Air escape holes are design to allow air removal during the heat exchange process while in the oven. The air holes shall be no larger than 6.35mm (1/4”) diameter.
The air holes need to be placed on the top face of the cash‐pak with a minimum of 8.5” (± .5”) apart from each other.
The following figures depict the right location of the air holes.
Air holes vertical position Air holes horizontal position
File details come from the government source that posted it. Updated .