This government file provides specifications for air escape holes in cash pak systems. The document outlines requirements for hole diameter, which must be no larger than 6.35mm, or 1/4 inch. Hole placement is also specified, with a minimum spacing of 8.5 inches between holes and defined vertical and horizontal positioning.

The related federal contract opportunity is a solicitation issued by the Department of the Treasury Bureau of Engraving and Printing seeking proposals for a cash pak system. Details include the solicitation number, brief product description, and issuing agency. Proposers are advised to carefully review specifications for air hole requirements in manufacturing cash paks.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Cash Pak Holes

Air escape holes are design to allow air removal during the heat exchange process while in the oven. The air holes shall be no larger than 6.35mm (1/4”) diameter.

The air holes need to be placed on the top face of the cash‐pak with a minimum of 8.5” (± .5”) apart from each other.

The following figures depict the right location of the air holes.

Air holes vertical position Air holes horizontal position