Summary of TEMA Restroom Trailer Specifications
This specification document outlines technical requirements for two restroom trailers to be procured by the Tennessee Emergency Management Agency (TEMA) under Sourcing Event 34101-13761. Each trailer must feature a two-compartment design with separate male and female facilities containing a total of eight stations: five toilets (two male, three female), two male urinals, four sinks (two male, two female), and four soap and paper towel dispensers (two male, two female). The trailers must be silver in exterior color and include a 2 5/16" coupler with electric tongue jack, spare mounted wheel and tire, exterior folding stainless steel entry handle, exterior patio light, dedicated exterior steps per door, and LED lighting throughout including two flood lights per side with one front and one rear light. Fresh water tank capacity must be at least 200 gallons with an electric water heater, while waste tank capacity must be at least 700 gallons. Each trailer requires dual 15,000 BTU air conditioning units, a mechanical room, 25-foot power cords, and sanitary hoses with adapters for waste tank evacuation. All materials must meet or exceed DOT, RVIA, ANSI, and NEC standards. Delivery is required to TEMA at 3041 Sidco Drive, Nashville, Tennessee 37204 within twelve months of purchase order receipt, with Andrew Bates (865-209-5575, andrew.bates@tn.gov) designated as the primary point of contact.
Safety compliance requirements include one carbon monoxide and smoke detector per restroom and one fire extinguisher per restroom. Each trailer must accommodate city water through a pressurized system via garden hose with an on-board pump. Power input specifications require that if multiple 50-amp connections are necessary, a power cube or power distribution box must be supplied with Cam-Lok input capability for generator connections. The specification document does not address pricing, contract terms, insurance requirements, or set-aside provisions; these details are contained in the related procurement opportunity documentation.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Event 34101-13761 Restroom Trailer Page 1 of 2
State of Tennessee Sourcing Event 34101-13761
TEMA Restroom Trailer Specs
Quantity: 2
1. General Requirements
a. Coupler: 2 5/16” with load distribution hardware including 2 1/2” shank vehicle hitch.
b. Tongue Jack: Electric
c. Exterior Color: Silver
d. Exterior Electrical Connection: 25’ cord to support all power requirements
e. Spare Wheel & Tire: Mounted
f. Exterior Folding Stainless Steel Entry Handle
g. Exterior Patio Light
h. Exterior Steps: Each exterior door shall have a dedicated step for entry, stowed with trailer during transport
i. Lighting: All interior and exterior lights shall be LED
j. Flood Lights: Two (2) per side, one (1) front, and one (1) rear
2. Compliance & Safety
a. CO/Smoke Detector: One in each restroom
b. Fire Extinguisher: One in each restroom
c. All materials must meet or exceed applicable DOT, RVIA, and ANSI standards.
d. Electrical system must meet NEC standards.
3. Restroom Stations
a. Unit to be designed with two compartments, (M/F) and single entry/exit door per compartment
b. Privacy partition for each station
c. Total Stations: 8
i. Toilets: 5 total (2 male, 3 female)
ii. Urinals: 2 (male)
iii. Sinks: 4 (2 male, 2 female)
iv. Soap & Paper Towel Dispensers: 4 (2 male, 2 female)
4. Fresh Water & Waste Systems
a. Fresh Water Tank Capacity: At least 200 gallons
b. Waste Tank Capacity: At least 700 gallons
c. Water Heater: Electric
d. Water Supply: City water, pressurized system via garden hose, on board pump
Event 34101-13761 Restroom Trailer Page 2 of 2
5. Mechanical & Utility Systems
a. Mechanical Room: Required
b. Air Conditioning:
i. Unit Type: 15,000 BTU each
ii. Unit Count: 2
c. Power Supply/Cords: 25’+ cord per required connection
d. Power Input: If power input requires multiple 50amp connections, a power cube or power distribution box must be supplied that has the needed outputs for the unit that accepts Cam-Lok input from generator.
e. Sanitary hoses and adapters: Must include flexible hoses and fittings for waste tank evacuation.
Delivery and Contact
Contractor shall deliver to Tennessee Emergency Management Agency (TEMA), 3041 Sidco Drive, Nashville, TN 37204 on or before the twelve (12) month time delivery after receipt of purchase order. The designated TEMA point of contact for the contractor shall be Andrew Bates at 865-209-5575 or andrew.bates@tn.gov. If the point of contact changes, TEMA shall notify the contractor as soon as possible. The Contractor shall coordinate all communication, progress updates, and inquiries with the respective points of contact as provided.
mailto:andrew.bates@tn.gov
| 1. General Requirements |
| a. Coupler: 2 5/16” with load distribution hardware including 2 1/2” shank vehicle hitch. |
| b. Tongue Jack: Electric |
| c. Exterior Color: Silver |
| d. Exterior Electrical Connection: 25’ cord to support all power requirements |
| e. Spare Wheel & Tire: Mounted |
| f. Exterior Folding Stainless Steel Entry Handle |
| g. Exterior Patio Light |
| h. Exterior Steps: Each exterior door shall have a dedicated step for entry, stowed with trailer during transport |
| i. Lighting: All interior and exterior lights shall be LED |
| j. Flood Lights: Two (2) per side, one (1) front, and one (1) rear |
| 2. Compliance & Safety |
| a. CO/Smoke Detector: One in each restroom |
| b. Fire Extinguisher: One in each restroom |
| c. All materials must meet or exceed applicable DOT, RVIA, and ANSI standards. |
| d. Electrical system must meet NEC standards. |
| 3. Restroom Stations |
| a. Unit to be designed with two compartments, (M/F) and single entry/exit door per compartment |
| b. Privacy partition for each station |
| c. Total Stations: 8 |
| i. Toilets: 5 total (2 male, 3 female) |
| ii. Urinals: 2 (male) |
| iii. Sinks: 4 (2 male, 2 female) |
| iv. Soap & Paper Towel Dispensers: 4 (2 male, 2 female) |
| 4. Fresh Water & Waste Systems |
| a. Fresh Water Tank Capacity: At least 200 gallons |
| b. Waste Tank Capacity: At least 700 gallons |
| c. Water Heater: Electric |
| d. Water Supply: City water, pressurized system via garden hose, on board pump |
| 5. Mechanical & Utility Systems |
| a. Mechanical Room: Required |
| b. Air Conditioning: |
| i. Unit Type: 15,000 BTU each |
| ii. Unit Count: 2 |
| c. Power Supply/Cords: 25’+ cord per required connection |
| d. Power Input: If power input requires multiple 50amp connections, a power cube or power distribution box must be supplied that has the needed outputs for the unit that accepts Cam-Lok input from generator. |
| e. Sanitary hoses and adapters: Must include flexible hoses and fittings for waste tank evacuation. |
File details come from the government source that posted it. Updated .