This is a technical specification drawing for a structural steel canopy or shelter structure. The document presents three orthogonal views (front elevation, top view, and side elevation) with detailed dimensional annotations and engineering specifications.

The structure features a 5.0 GA 07 Round Tubing frame design with total estimated steel weight of 2,982 lbs, including a single column weight of 148.4 lbs and upper frame weight of 558.7 lbs. Design loads are specified per the International Building Code 2024, with 5 PSF live load, 5 PSF snow load, and 115 MPH wind loads per ASCE 7-22 equivalent stress provisions. The structure is classified as 3-Sec. Gust, Risk Category II & Exposure C. Overall dimensions include length (L) of 33'-0", width (W) of 29'-0", height (H) of 16'-0", roof rise (R) of 5'-8", head height (HT) of 21'-8", depth (D) of 45'-11", roof length (RL) of 10'-6", and eave length (EL) of 18'-0". The design references compliance with AISC 7-22 standards and ISO 2624 EQ 15-15 for wind speed calculations.