ESBD_484259_1770149331269_EXHIBIT B - Burnet County Annex_REVISION 1.pdf
PDF 5 MB Posted
- Attached to
- RE-BID LIFT INSTALLATION
- Solicitation number
- 26-4090-05
- Issued by
- Brazos County, Texas
About this file
This document is an Exhibit B, specifically a County Annex document prepared for Burnet County, Texas in connection with a re-bid lift installation procurement (Bid #26-4090-05). The project involves the provision and installation of a Cibes Symmetry limited use/limited application (LU/LA) hydraulic passenger elevator at 127 E. Jackson, Burnet, Texas 78611. The elevator must meet specific technical requirements including a 1,400-pound capacity, car dimensions not exceeding 48 inches by 54 inches, two stops, and a travel speed of 30 feet per minute. The solicitation requires a factory-trained, licensed, and authorized Cibes Symmetry dealer to perform all installation work, provide complete equipment and materials, and achieve full operational capability. Key milestone dates include a mandatory pre-bid meeting on January 22, 2026 at 10:00 AM at the project site, a deadline for submitting questions on January 27, 2026 at 12:00 PM, and a sealed bid submission deadline of February 3, 2026 at 10:00 AM at the Burnet County Auditor Office, 133 E. Jackson, Burnet, Texas 78611, with electronic submission available to bids@burnetcountytexas.org. Bids will be evaluated within 60 calendar days following bid opening, with contract award expected during this period.
The contract deliverables include complete installation, a three-year limited parts warranty covering defective components, and a three-year maintenance service agreement with inspections every six months as required by ASME A17.1 standards. All work must comply with ICC/ANSI 117.1, NEC, and ASME A17.1 guidelines, with designs subject to local, city, and state approval before and after installation. Bidders must submit a 5% bid guaranty with their sealed bids and provide certifications including non-collusion affidavits, debarment certifications, certificate of interested parties (Form 1295), tax record compliance, family code compliance, vendor references, and proof of insurance. Performance and payment bonds, each in the amount of 100% of the contract value, are mandated, indicating the anticipated contract value exceeds $100,000 and $25,000 respectively. Burnet County reserves the right to reject any or all bids and to award by line item to the lowest responsible bidder meeting all specification requirements. The procurement documentation does not specify set-aside designations for disadvantaged enterprises or identify any incumbent vendors or existing infrastructure integration requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
XX/AX.X
Ref
XX/AX.X
Ref
XX/AX.X
Ref
AX.X
XX
Ref
X
LEVEL NAME
ELEVATION
LEVEL HEAD, DATUM
POINT
CL
X
PROJECT NORTH
TRUE NORTH
150 SF
ROOM
NAME
AREA NOT IN CONTRACT
REVISION CLOUD &
REVISION TAG/ NUMBER
COLUMN REFERENCE
GRID
SPOT ELEVATION
x' - x"
ROOM LABEL
WALL SECTION
XX/AX.X
Ref
BUILDING SECTION
EXTERIOR ELEVATION
INTERIOR ELEVATION
KEY NOTE
CENTERLINE
PARTITION TAG
DETAIL CALLOUT
X
DOOR TAG
GLAZING TAG
XX/AX.XX X
X
X
PROJECT
NORTH
TRUE
NORTH
� IMPORTANT:
SHOULD A CONFLICT AND/ OR DISCREPANCY ARISE BETWEEN THE SPECIFICATIONS
AND/ OR DRAWINGS, THE HIGHEST QUALITY AND QUANTITY SHALL BE PROVIDED
AND INSTALLED.
GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT ALL TEXAS
DEPARTMENT OF LICENSING AND REGULATION (TDLR), TEXAS ACCESSIBILITY
STANDARDS (TAS), AND AMERICANS WITH DISABILITIES ACT (ADA)
REQUIREMENTS ARE MET.
THE ARCHITECT'S PACKAGE IS INTENDED TO BE VIEWED IN FULL COLOR. WORK
INCORRECTLY INSTALLED AS A RESULT OF VIEWING THE DRAWINGS IN
GRAYSCALE, SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO
CORRECT.
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
G-001
COVER SHEET
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
1 THE CONTRACTOR, IN ACCORDANCE WITH THE PROVISIONS SET FORTH IN THESE CONTRACT
DOCUMENTS, SHALL PROVIDE ALL MATERIALS, EQUIPMENT, LABOR AND SUPERVISION TO
COMPLETE ALL WORK DESCRIBED HEREIN AND WHICH CAN BE REASONABLY INFERRED TO
BE REQUIRED IN THESE DRAWINGS FOR CONSTRUCTION.
2 PRIOR TO BEGINNING CONSTRUCTION, CONTRACTOR TO VERIFY ALL DIMENSIONS, AND
CONDITIONS, AND SHALL NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES.
PROCEEDING WITH WORK SHALL CONSTITUTE ACCEPTANCE BY THE CONTRACTOR THAT ALL
CONDITIONS ARE ACCEPTABLE AND THE CONTRACTOR SHALL ASSUME FULL
RESPONSIBILITY.
3 DO NOT SCALE DRAWINGS - IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE
RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING
WITH CONSTRUCTION.
4 CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE CODES,
REGULATIONS, ACTS, AND COVENANTS. HAVING JURISDICTION.
5 THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, INSPECTION FEES, AND
DEPOSITS REQUIRED FOR THE PROVISION AND INSTALLATION OF ALL WORK. IT SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO CALL FOR LOCAL INSPECTIONS AND OBTAIN
APPROVAL FROM INSPECTORS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
INSURANCE AND NECESSARY INCIDENTALS
6 SEAL ALL CRACKS AROUND STRUCTURAL MEMBERS, BRACING, PIPES, CONDUITS, DUCTS AND
BETWEEN WALLS AND ROOF DECK WHERE AIR INFILTRATION BETWEEN CONDITIONED AND
NON-CONDITIONED (EXTERIOR) SPACES MAY OCCUR (I.E. SEAL THE BUILDING ENVELOPE).
7 CONCEAL ALL PIPING IN GYPSUM WALLBOARD, TYPE 'X'. WHERE PIPING IS TOO LARGE,
WALLS ARE TO BE FURRED-OUT THE MINIMUM REQUIRED TO CONCEAL PIPING. INFORM
ARCHITECT PRIOR TO PROCEEDING WITH THE WORK.
8 PROVIDE DOUBLE STUDS, BLOCKING, AND/OR DIAGONAL BRACING AT JAMBS OF DOORS,
AND ALL WALL OPENINGS.
9 PROVIDE TRANSITION STRIPS AT ALL CHANGES IN FLOOR FINISH.
10 THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MEANS AND METHODS OF
CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT
THE STRUCTURE AND PERSONNEL DURING CONSTRUCTION. SUCH MEASURES SHALL
INCLUDE BUT NOT BE LIMITED TO BRACING, SHORING OF LOADS DUE TO CONSTRUCTION
EQUIPMENT, EXCAVATION PROTECTION, SCAFFOLDING, AND JOB SITE SAFETY. OBSERVATION
VISITS TO THE SITE BY ARCHITECT, OWNER, OR ENGINEER SHALL NOT INCLUDE INSPECTION
OF ABOVE ITEMS
11 FIRE EXTINGUISHERS SHALL BE PURCHASED AND INSTALLED BY THE CONTRACTOR PER
LOCAL FIRE DEPARTMENT AND BUILDING CODE REQUIREMENTS.
12 ELECTRICAL PANEL AND FIRE EXTINGUISHER CABINETS LOCATED IN RATED PARTITIONS
SHALL BE BACKED WITH DRYWALL TO MAINTAIN FIRE RATING
13 ALL DOORS PENETRATING "1 HOUR" CORRIDOR WALLS SHALL BE 45-MINUTE RATED DOORS
UNLESS NOTED OTHERWISE.
14 PENETRATIONS THROUGH WALLS OR CEILINGS NOTED TO BE FIRE RATED SHALL BE FIRE
SAFED AND SEALED TO MAINTAIN THE RATING. ALL WALL AND FLOOR CEILING
PENETRATIONS SHALL BE PROTECTED BY PRODUCTS EQUIVALENT TO USG FIRE CODE
SEALANT AND THERMAFIBER SAFING INSULATION PER MANUFACTURER'S INSTRUCTIONS
AND CONFORMING TO SYSTEM WL-7001, WL-7002, WL-1027, WL-3023, WL-1039, AND/OR UL
SYSTEM #CAJ-0032, CAJ-0032, CAJ-3045. DUCT WORK PENETRATIONS THROUGH RATED
ASSEMBLIES SHALL BE PROVIDED WITH AN APPROPRIATELY TESTED/RATED FIRE AND SMOKE
DAMPER.
15 CONTRACTOR TO PROVIDE FIRE / SMOKE DETECTION AND ALARM SYSTEM.
16 IT IS THE INTENT OF THE OWNER AND ARCHITECT THAT THIS PROJECT COMPLY WITH THE
AMERICANS WITH DISABILITIES ACT AND TEXAS ACCESSIBILITY STANDARDS.
17 THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL AGREE TO WARRANTY THE
WORK, INCLUDING BOTH MATERIALS AND WORKMANSHIP, FOR A PERIOD OF ONE YEAR
FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER. CONTRACTOR SHALL REMEDY, AT
NO EXPENSE TO THE OWNER, ANY DEFECTS IN THE WORK WHICH BECOME APPARENT
DURING THE WARRANTY PERIOD.
OWNER:
BURNET COUNTY AUDITOR'S OFFICE
133 E JACKSON ST
BURNET, TX 78611
CONTACT:JOE DON DOCKERY
CELL #:512-715-5235
GENERAL CONTRACTOR:
TBD
PROJECT #:TBD
TBD
TBD
TBD
TBD
CONTACT:TBD
CELL #:TBD
EMAIL:TBD
1 FIRE ALARM SYSTEM. A FIRE ALARM SYSTEM WILL BE INSTALLED PER THE FIRE CODE AND
NFPA STANDARD 72. THE APPROVAL OF THIS SYSTEM WILL BE ADDRESSED THROUGH A
DEFERRED SUBMITTAL. APPROVAL OF THE BUILDING PERMIT DOES NOT IMPLY APPROVAL TO
INSTALL THE FIRE ALARM SYSTEM.
2 EMERGENCY SERVICES. NORMAL BUILDING LIGHTING WILL BE SUPPLIED FROM DEDICATED
LIGHTING CIRCUITS AND EMERGENCY LIGHTING WILL BE SUPPLIED FROM THE SAME
CIRCUITS. A SINGLE PRIMARY HOT FROM THE BREAKER WILL BE SPLIT BETWEEN THE SWITCH
AND EMERGENCY HOT. THE PRIMARY HOT WILL SUPPLY THE LIGHTING FIXTURES AND WILL
BE ROUTED THROUGH THE SWITCHES LOCATED ON THE CIRCUIT. THE EMERGENCY HOT WILL
SUPPLY THE BACKUP BATTERIES ONLY. THE EMERGENCY HOT WILL BE INSTALLED AS AN
UNSWITCHED, CONSTANT HOT. THE BREAKER SUPPLYING THE CIRCUITS MUST BE TURNED
OFF TO CUT POWER TO THE EMERGENCY HOT. COORDINATE WITH MPE SYSTEMS
DRAWINGS.
3 PORTABLE FIRE EXTINGUISHERS. PORTABLE FIRE EXTINGUISHERS WILL BE INSTALLED SO THAT
NO POINT IN THE BUILDING WILL BE LOCATED MORE THAN 75 FEET FROM AN
EXTINGUISHER. THIS DISTANCE IS MEASURED BY THE PATH OF TRAVEL. THE MINIMUM
RATING FOR AN EXTINGUISHER IS 2A:10BC. 5-LB DRY CHEMICAL UNITS, WHICH CARRY A
3A:40BC RATING. EXTINGUISHERS SHALL BE MOUNTED ADJACENT TO EXIT DOORS AND AT
INTERMIDIATE LOCATIONS TO MEET TRAVEL DISTANCE REQUIREMENTS. EXTINGUISHERS
MUST BE MOUNTED IN A VISIBLE AND ACCESIBLE LOCATION. THE TOP OF EXTINGUISHER
SHALL NOT BE MORE THAN 5 FEET ABOVE THE FINISHED FLOOR LEVEL. EXTINGUISHERS
MUST BE PROVIDED WITH A CURRENT INSPECTION TAG BY A LICENSED FIRE PROTECTION
CONTRACTOR.
4 MAIN ELECTRICAL DISCONNECT. THE MAIN ELECTRICAL DISCONNECT MUST BE LOCATED ON
THE EXTERIOR OF THE BUILDING AND APPROVED SIGNAGE TO BE PROVIDED AND INSTALLED
TO IDENTIFY THE LOCATION OF THE MAIN ELECTRICAL DISCONNECT. THE DISCONNECT
MUST BE A KNOX-VAULT 4500 SERIES POWER SHUTDOWN. PRIOR TO INSTALLATION, THE
SIZE, DESIGN AND PLACEMENT OF IDENTIFICATION SIGNS MUST BE APPROVED BY THE FIRE
DEPARTMEN. COORDINATE WITH MPE SYSTEMS DRAWINGS.
5 MAIN GAS DISCONNECT. THE MAIN GAS DISCONNECT MUST BE LOCATED ON THE EXTERIOR
OF THE BUILDING AND APPROVED SIGNAGE TO BE PROVIDED AND INSTALLED TO IDENTIFY
THE LOCATION OF THE MAIN GAS DISCONNECT. PRIOR TO INSTALLATION, THE SIZE, DESIGN
AND PLACEMENT OF IDENTIFICATION SIGNS MUST BE APPROVED BY THE FIRE DEPARTMENT.
COORDINATE WITH MPE SYSTEMS DRAWINGS.
6 CARBON DIOXIDE SYSTEMS WITH MORE THAN 100 POUNDS (45.4 KG) OF CARBON DIOXIDE
USED IN BEVERAGE DISPENSING APPLICATIONS SHALL COMPLY WITH THE 2015
INTERNATIONAL FIRE CODE, SECTIONS 5307.2 THROUGH 5307.5.2.
SHEET # SHEET NAME
CURRENT REVISION
# DESCRIPTION DATE
00 - GENERAL
G-001 COVER SHEET
G-101 LIFE SAFETY PLAN 1 2ND FLOOR LAYOUT 8/11/2025
G-501 ACCESSIBILITY GUIDELINES
G-502 ACCESSIBILITY GUIDELINES
03 - STRUCTURAL
S-000 STRUCTURAL NOTES
S-001 STRUCTURAL NOTES
S-002 STRUCTURAL NOTES
S-003 SPECIAL INSPECTIONS
S-100 FOUNDATION PLAN
S-200 FRAMING PLAN
S-201 ROOF FRAMING PLAN
S-300 TYPICAL CONCRETE DETAILS
S-301 SLAB ON GRADE FOUNDATION
SECTIONS
S-302 SLAB ON GRADE FOUNDATION
SECTIONS
S-303 CONCRETE REPAIR DETAILS
S-600 TYPICAL WOOD DETAILS
S-601 TYPICAL WOOD DETAILS
S-610 TYPICAL WOOD SHEAR WALL DETAILS
S-611 TYPICAL WOOD SHEAR WALL DETAILS
S-612 TYPICAL WOOD SHEAR WALL DETAILS
S-630 STICK FRAME FLOOR FRAMING
DETAILS
S-650 MONOSLOPE ROOF TRUSS DETAILS
04A - ARCHITECTURAL SITE
AS-101 ARCHITECTURAL SITE PLAN
04B - ARCHITECTURAL DEMOLITION
AD-101 DEMOLITION FLOOR PLANS
AD-121 DEMOLITION ROOF PLAN & EXTERIOR
ELEVATIONS
04C - ARCHITECTURAL
A-101 ARCHITECTURAL FLOOR PLANS 1 2ND FLOOR LAYOUT 8/11/2025
A-111 REFLECTED CEILING PLANS 1 2ND FLOOR LAYOUT 8/11/2025
A-121 ROOF PLAN
A-131 FINISH PLANS 1 2ND FLOOR LAYOUT 8/11/2025
A-201 EXTERIOR ELEVATIONS 1 2ND FLOOR LAYOUT 8/11/2025
A-221 INTERIOR ELEVATIONS 1 2ND FLOOR LAYOUT 8/11/2025
A-301 BUILDING SECTIONS 1 2ND FLOOR LAYOUT 8/11/2025
A-311 WALL SECTIONS 1 2ND FLOOR LAYOUT 8/11/2025
A-401 ENLARGED PLANS 1 2ND FLOOR LAYOUT 8/11/2025
A-402 ENLARGED PLANS
A-431 ENLARGED FINISH PLANS
A-511 DETAILS 1 2ND FLOOR LAYOUT 8/11/2025
A-512 STAIR DETAILS
A-522 MILLWORK DETAILS
A-602 INTERIOR PARTITION TYPES 1 2ND FLOOR LAYOUT 8/11/2025
A-611 DOOR SCHEDULES AND DETAILS
A-631 STOREFRONT & WINDOW SCHEDULE 1 2ND FLOOR LAYOUT 8/11/2025
06 - MECHANICAL
M-001 MECHANICAL COVER SHEET
M-002 MECHANICAL DETAILS
M-003 MECHANICAL SCHEDULES
M-201 MECHANICAL HVAC PLANS - LEVEL 1
07 - PLUMBING
P-001 PLUMBING COVER SHEET
P-002 PLUMBING DETAILS
P-003 PLUMBING SCHEDULES
P-101 PLUMBING DWV PLANS
P-201 PLUMBING DOMESTIC WATER PLANS
P-301 PLUMBING RISER DIAGRAMS
08 - ELECTRICAL
E-001 ELECTRICAL COVER SHEET
E-002 ELECTRICAL SPECIFICATIONS
E-003 ELECTRICAL DETAILS
E-004 ELECTRICAL ONE-LINES & SCHEDULES
E-201 ELECTRICAL LIGHTING PLAN
E-301A ELECTRICAL POWER PLAN
E-301B ELECTRICAL HVAC POWER PLAN
BURNET COUNTY ANNEX
127 EAST JACKSON STREET, BURNET TX 78611
LOCATION MAP
PROJECT GENERAL NOTES
GENERAL NOTES
PROJECT TEAM DIRECTORY:
REQUIREMENTS
ARCHITECT OF RECORD:
LEVY DYKEMA
PROJECT #:LD10-23055
620 CONGRESS AVE., STE 100
AUSTIN, TEXAS 78701
WWW.LEVYDYKEMA.COM
SYMBOL LEGEND
SHEET INDEX
PROJECT
LOCATION
VIEW FROM E. JACKSON ST.
STRUCTURAL ENGINEER:
STRUCTURES PE, LLP
PROJECT #:23.078
4315 GUADALUPE ST. STE 301
AUSTIN, TX
STRUCTURESTX.COM
(512)499-0919
MEP ENGINEER:
HOLLINGSWORTH PACK
PROJECT #:33-1408
3801 S CONGRESS AVE, STE 110
AUSTIN, TX
HOLLINGSWORTHPACK.COM
(512) 275-6060
# DATE ISSUE
FA
FP
SD
DN
12"
24"
150 SF
ROOM
NAME
OCCUPANCY
ITEM NOT SELECTED
ITEM SELECTED
OCCUPANCY
ROOM AREA
# OF OCCUPANTS
(EATD) EXIT ACCESS
TRAVEL DISTANCE
(CPET) COMMON PATH OF
EGRESS TRAVEL DISTANCE
# OF PEOPLE EGRESSING
THROUGH DOOR
REQUIRED EGRESS WIDTH
ACTUAL EGRESS WIDTH
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE ALARM/STROBE
FIRE PULL
FIRE ACCESS CONTROL
PANEL
EXIT SIGN
SMOKE DETECTOR
(DECL) DEAD END CORRIDOR
LENGTH
1-HR FIRE RATED WALL
2-HR FIRE RATED WALL
KNOX BOX
KNOX
F.E.C.-#
F.E.-#
F.A.C.P.
OCCUPANCY
BUSINESS
1,940 SF
BUSINESS
OPEN
WORKSPACE
OFFICE 1
CONFERENCE
WORK
ROOM
BREAKROOM
NOT IN
SCOPE
UP
34"
32"
EATD = 66' - 8"
HVAC
P R
IN
T E R
S
34"
32"
F.E.C. #1
OFFICE 2
34"
32"
EATD = 63' - 1"
OCCUPANCY
BUSINESS
EATD = 50' - 9"
DN
EATD = 46' - 0"
EATD = 22' - 3"
STORAGE
FLEX OFFICE
LAB
SERVER
ROOM
OFFICE
OFFICE
GREG'S
OFFICE
MEETING
ROOM
OPEN
WORKSPACE
BREAKROOM
30"
32"
ELEV. &
MECH. RM.
1,935 SF
BUSINESS
F.E.C. #1
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
G-101
LIFE SAFETY PLAN
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
1 THE PURPOSE OF THE LIFE SAFETY PLANS IS TO ILLUSTRATE IN A SCHEMATIC FASHION, THE
APPLICABLE EXITING, FIRE-RESISTANCE, AND LIFE SAFETY CONCEPTS UTILIZED BY THIS PROJECT;
INCLUDING, BUT NOT LIMITED TO:
- OCCUPANCY CLASSIFICATIONS
- OCCUPANCY LOAD FACTORS
- EXIT LOCATIONS, EXIT PATHS & CAPACITY
- FUNCTION OF SPACE
- FIRE-RESISTANCE RATED CONSTRUCTION
- AND OTHER STRATEGIES RELATED TO THE CODE COMPLIANCE APPROACH OF THIS PROJECT.
2 ADDITIONAL DETAILED REQUIREMENTS APPLY TO THE CONSTRUCTION OF PARTITIONS, FIRE
RATED DOOR ASSEMBLIES, INTERIOR GLAZED OPENINGS, DUCTS, SMOKE AND FIRE DAMPERS
AND THROUGH-PENETRATION FIRE STOPPING ,IF APPLICABLE. REFER TO THE DRAWINGS OF
EACH DISCIPLINE FOR THESE REQUIREMENTS.
3 ADDITIONAL DETAILED REQUIREMENTS SHOWN ELSEWHERE MAY REQUIRE CONSTRUCTION
HAVING GREATER FIRE RATINGS, MORE EXTENSIVE FIRE-RATED CONSTRUCTION,OR MORE
COMPLEX ASSEMBLIES THAN INDICATED. WHEN PROVIDED, THE ADDITIONAL DETAILED
REQUIREMENTS SHALL GOVERN.
4 FIRE BARRIERS SHALL EXTEND FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING
ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR DECK
ABOVE AND SHALL BE SECURELY ATTACHED THERETO. SUCH FIRE BARRIERS SHALL BE
CONTINUOUS THROUGH CONCEALED SPACES.
5 SHAFT ENCLOSURES SHALL BE CONSTRUCTED AS FIRE BARRIERS.
6 FIRE PARTITIONS SHALL EXTEND FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING
ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR DECK
ABOVE OR TO THE FIRE-RESISTANCE-RATED FLOOR/CEILING OR ROOF/CEILING ASSEMBLY
ABOVE, AND SHALL BE SECURELY ATTACHED THERETO.
7 SMOKE BARRIERS SHALL FORM AN EFFECTIVE MEMBRANE CONTINUOUS FROM OUTSIDE WALL
TO OUTSIDE WALL AND FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING ASSEMBLY
BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, DECK OR SLAB ABOVE,
INCLUDING CONTINUITY THROUGH CONCEALED
SPACES.
8 SMOKE PARTITIONS SHALL EXTEND FROM THE TOP OF THE FOUNDATION OR FLOOR BELOW TO
THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, DECK OR SLAB ABOVE OR TO THE
UNDERSIDE OF THE CEILING ABOVE WHERE THE CEILING MEMBRANE IS CONSTRUCTED TO
LIMIT THE TRANSFER OF SMOKE.
9 DIRECTIONAL SIGNAGE SHALL BE PROVIDED AT EACH ELEVATOR LANDING THAT STATES "IN
FIRE EMERGENCY, DO NOT USE THE ELEVATOR, USE THE STAIRS".
10 INTERIOR WALL & CEILING FINISHES SHALL HAVE A FLAME SPREAD INDEX RATING OF NO MORE
THAN CLASS 'B' AT VERTICAL EXITS & EXIT PASSAGEWAYS, EXIT ACCESS CORRIDORS, AND
OTHER EXIT WAYS.
11 INTERIOR WALL & CEILING FINISHES SHALL HAVE A FLAME SPREAD INDEX RATING OF NO MORE
THAN CLASS 'C' AT ROOMS AND ENCLOSED SPACES.
12 ALL MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD INDEX
RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 50.
13 FIRE EXTINGUISHERS SHALL BE LOCATED SUCH THAT TRAVEL DISTANCE TO AN EXTINGUISHER
SHALL NOT EXCEEED 75' (WHERE REQUIRED BY CODE).
14 LEVEL / AREA MAIN OCCUPANCY EXIT SIGN LOCATIONS MAY NOT BE SHOWN ON THIS SHEET.
REFERENCE ELECTRICAL SHEETS FOR ALL EXIT SIGN LOCATIONS.
15 FIRE RESISTIVE ASSEMBLY DETAILS, IF APPLICABLE, ARE LOCATED ELSEWHERE IN THIS DRAWING
SET. REFERENCE THE SHEET INDEX.
16 ELEVATOR HOISTWAY OPENINGS SHALL BE PROTECTED AS REQUIRED BY CODE,
CORRESPONDING TO THE RATING OF THE HOISTWAY.
17 EVERY ROOM / SPACE WITH AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD
POSTED IN A CONSPICUOUS SPACE.
18 EACH PARTITION SHOWN ON THE DRAWINGS TO HAVE A FIRE AND/OR SMOKE RESISTANCE
RATING SHALL BE IDENTIFIED AS SUCH WITH A LABEL ABOVE THE CEILING ON EACH SEGMENT
OF THE WALL AND 6' - 0" MAX. EACH SIDE.
BASIC OCCUPANCY GROUPS: TYPE OF CONSTRUCTION:
USES & CONSTRUCTION TYPES:
USE GROUP(S) AND CONSTRUCTION TYPE(S) PER IBC CHAPTERS 3, 4, 5, AND 6
TYPE V : A B
FIRE-RESISTIVE RATING REQUIREMENTS FOR BUILDING ELEMENTS (PER IBC TABLE 601):
MIN. FIRE-RESISTIVE REQUIREMENTS:
TYPE OF CONSTRUCTION
PRIMARY STRUCTURAL FRAME
EXTERIOR BEARING WALLS
INTERIOR BEARING WALLS
EXTERIOR NON-BEARING WALLS
INTERIOR NON-BEARING WALLS
FLOOR CONSTRUCTION
ROOF CONSTRUCTION
ADDITIONAL FIRE-RESISTIVE RATINGS:
BUILDING ELEMENT
REQ'D RTG
(HRS)
SHAFT ENCLOSURES (IBC 713.4)
BUILDING ELEMENT
REQ'D RTG
(HRS)
<4 STORIES
EXIT ENCLOSURES (IBC 1023.2)
<4 STORIES
EXIT PASSAGEWAYS (IBC 1024.3) 1
OCCUPANCY
OCCUPANT
LOAD SERVED
REQ'D
RATING (HRS)
MEANS OF EGRESS SIZING:
BUILDING ELEMENT
MINIMUM REQUIRED
EGRESS WIDTH
STAIRWAYS
OTHER EGRESS COMPONENTS
OCCUPANCY
MAXIMUM COMMON
PATH OF TRAVEL (IBC
TABLE 1006.2.1)
EXIT ACCESS
TRAVEL DISTANCE
(IBC TABLE 1017.2)
DEAD END
CORRIDOR LENGTH
(IBC 1020.5)
BUILDING LIMITS
MAX. FLOOR AREA:
ACTUAL FLOOR AREA:
MAXIMUM BUILDING HEIGHT
ACTUAL BUILDING HEIGHT
ALLOWABLE STORIES ABOVE GRADE
ACTUAL STORIES ABOVE GRADE
BUSINESS ( GROUP B )
B >30 1
0.3
0.2
B 75' 200' 20'
V-B
9,000 SF
3,875 SF
40' - 0"
30' - 6"
APPLICABLE CODES:
APPLICABLE CODES & STANDARDS
AUTHORITY HAVING JURISDICTION:
TDLR NUMBER: TBD
2021 INTERNATIONAL BUILDING CODE WITH AMENDMENTS
2015 INTERNATIONAL EXISTING BUILDING CODE WITH AMENDMENTS
2015 INTERNATIONAL FIRE CODE WITH AMENDMENTS
2021 INTERNATIONAL PLUMBING CODE WITH AMENDMENTS
2015 INTERNATIONAL MECHANICAL CODE WITH AMENDMENTS
2021 INTERNATIONAL ENERGY CONSERVATION CODE WITH AMENDMENTS
2015 NFPA 101 LIFE SAFETY CODE
2014 NATIONAL ELECTRICAL CODE WITH AMENDMENTS
2012 TEXAS ACCESSIBILITY STANDARDS (TAS/TDLR)
BURNET, TEXAS
PROJECT GENERAL NOTES
LIFE SAFETY LEGEND:
OCCUPANCY LOAD
SCALE: 3/16" = 1'-0"
LIFE SAFTY PLAN - FIRST FLOOR
OCCUPANCY TYPE AREA OCCUPANT LOAD FACTOR OCCUPANCY
01 FIRST FLOOR
BUSINESS 1,940 SF 100 SF 20
02 SECOND FLOOR
BUSINESS 1,935 SF 100 SF 20
SCALE: 3/16" = 1'-0"
LIFE SAFETY PLAN - SECOND FLOOR
FLOOR CLASSIFICATION
OCCUPANCY
LOAD
WATER CLOSETS LAVATORIES DRINKING
FOUNTAINS
SERVICE
SINKSMEN WOMEN MEN WOMEN
1ST FLOOR BUSINESS 20 .4 .4 .25 .25 .2 1
2ND FLOOR STORAGE 4 .02 .02 0.02 .02 0.004 0*
TOTAL 24 1 1 1 1 1** 1
REQUIRED PLUMBING FIXTURES
*Per IBC 2015 Table 1004.1.2 and IPC 2015 Table 403.1
**SEEKING ALTERNATE COMPLIANCE METHOD OF: TENANT STAFF TO UTILIZE EXISTING DRINKING
FOUNTAINS IN CURRENT ANNEX OFFICE (WITHIN 500 FEET PER 2015 IPC) AND OWNER TO PROVIDE
BOTTLED WATER TO THE PUBLIC. SEE LETTER EXHIBIT.
# DATE ISSUE
1 8/11/2025 2ND FLOOR
LAYOUT
SERVER ROOM CEILING (CLG-03): 1 HR FIRE RATED, UL P522 ROOF - CEILING ASSEMBLY
SERVER ROOM FLOORING: 1 HR RATED, UL L521 FLOOR- CEILING ASSEMBLY
UP
DN
1/A-201
5/A-3015/A-301
2/A-3012/A-301
/A
-3
/A
-3
2/A-201
CONFERENCE
OFFICE 1
OPEN
WORKSPACE
1/A-3011/A-301
BREAKROOM
MENS
RESTROOM
ENTRY
HALL
UTILITY
UP
WORK
ROOM
NOT IN
SCOPE
NOT IN
SCOPE
A-401
REF.
H6
H6
CL
V.I.F.
9" 5' - 0" 2' - 9 3/4"
4' - 11"
2' - 9 3/4"
V.I.F.
4' - 11" V.I.F.
1' - 11 3/4"
/A
-3
/A
-3
AA01
+/- 25' - 4"
ALIGN
A-401
4' - 5 3/4" 5' - 5 1/2" 11' - 7 1/2" 3 1/2"
/4
/4
HVAC
WOMENS
RESTROOM
22' - 5 1/4" V.I.F.
C L C L
C L C L
/2
/2
/2
/2
22' - 5 1/4"
11' - 1 1/2" 3' - 0" 11' - 2"
V .I.
F.
1"
V .I.
F.
4 5
4' - 2 1/4"
127MECH.
A6-1F
A3-1F
A6-1F
A6-1F A6-1F
A6-1F
H6
H6
A6
A-5125
10 1011
DATA
RACK
WK
A-402
L3-S
ELVORON CPL
STYLE 1
42X60 CAB SIZE
H3-S
J6
INITIAL DESIGN INTENT TO
MATCH ADJACENT
BUILDING STAIR DESIGN.
NEW EGRESS STAIR DESIGN
TO BE FINALIZED.
1' - 8 1/4" 1' - 8 1/4"
/2
2' - 7 1/2"
11' - 7 1/2"
2' - 11 3/4"
1' - 0"
2' - 8 7/8"
6' - 3 3/4"
/2
V .I.
F.
/2
/8
/8
8' - 8 3/8" 6' - 11 3/4" 8' - 8 1/4"
21' - 6 3/4"
16' - 3 1/4"
H3-S
3 1/2" P
R
IN
T E R
S
OFFICE 2
C L C L
C L C L
C L C L
C L C L
C L
/2
/2
/2
ELEV.
SHAFT
A-631
1' - 4"
C
LE
A R
A3
1/A-202
2/A-202
1/A-201
5/A-3015/A-301
2/A-3012/A-301
/A
-3
/A
-3
2/A-201
1/A-3011/A-301
DN
NOT IN
SCOPE
NOT IN
SCOPE
/A
-3
/A
-3
D C C
3' - 3" 12' - 6" 3' - 3"
2' - 9" 3' - 0" 4' - 5 3/4" 3' - 0" 4' - 11 1/4"
3' - 0"
2' - 9"
/A
-2
E X
T . F
IN
IS
H T
O A
LI
G
N W
IT
H
A D
J.
A
N N
E X
F A
C A
D E
10 1010
STORAGE
WOMEN'S
RESTROOM
MEN'S
RESTROOM
ELEV. &
MECH. RM.
4' - 0 1/2"
/2
/2
8' - 6 3/8"
CL
2 3/4"
V.I.F.
23' - 11" 6 1/8"
A6-1F
A6-1F
A6-1F
A6-1F
WK
A-402
INITIAL DESIGN INTENT TO
MATCH ADJACENT
BUILDING STAIR DESIGN.
NEW EGRESS STAIR DESIGN
TO BE FINALIZED.
21' - 5"
1' - 2 3/4"1' - 2 1/4"
/2
+/- 6" 21' - 3 3/4" +/- 6"
2 1/2" 22' - 0" 2 3/4"
ELEV.
SHAFT
8' - 7 1/2" 13' - 4 1/2"
BREAKROOM
LAB
SERVER
ROOM
OFFICE
GREG'S
OFFICE
MEETING
ROOM
CLEAR
4' - 5 1/4"
/2
8' - 6"
12' - 8 3/8"
CLEAR
6' - 0"
C L
C L
/2
FLEX OFFICE
OPEN
WORKSPACE
HALL
8 12
6' - 11" 8' - 3 1/2"
4' - 5 1/2"
A3-1F
A3-S
A3-S
A3-S
A6A3-S
A6-S
A3-S
A6-S
10' - 0"
12' - 0"
CLEAR
4' - 9"
OFFICE
A3-S
A3-S
A3-S
A3-1F
8' - 11"
1/A-202
2/A-202
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
PROJECT
NORTH
TRUE
NORTH
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
A-101
ARCHITECTURAL
FLOOR PLANS
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
1 REFER TO SHEET A-602 FOR INTERIOR PARTITON TYPES.
2 REFER TO SHEET A-611 FOR DOOR SCHEDULE
3 REFER TO SHEET A-631 FOR WINDOW SCHEDULE
4 REFER TO SHEET G-601 FOR FINISH SCHEDULE.
5 REF. MEP FOR ITEMS REQUIRED BUT NOT SHOWN ON ARCHITECTURAL DRAWINGS. PROVIDE
LOCKABLE ACCESS PANELS AT ALL LOCATIONS INDICATED AS NEEDING ACCESS ON MEP
DRAWINGS. PROVIDE NECESSARY BLOCKING, FRAMING, ETC. FOR ACCESS PANELS.
6 DO NOT CUT ANY STRUCTURAL ELEMENT IN A MANNER THAT WILL DIMINISH THEIR
LOAD-BEARING CAPACITY. NOTIFY STRUCTURAL ENGINEER AND DO NOT PROCEED WITH ANY
STRUCTURAL CUT WITHOUT THEIR WRITTEN APPROVAL,
7 EXTERIOR WALLS ARE DIMENSIONED TO EXTERIOR FACE OF STUD OR EDGE OF SLAB. ALL
EXISTING WALLS ARE DIMENSIONED TO FAC OF FINISH. VERIFY ALL EXISTING WALL AND
WINDOW DIMENSIONS IN FIELD PRIOR TO CONSTRUCTION.
8 EXTERIOR WALLS (ABOVE GRADE) SHALL ACHIEVE A MINIMUM OF R-20 THERMAL ENVELOPE
INSULATION COMPONENT REQUIREMENTS (2015 IECC TABLE C402.1.3).
9 EXTERIOR OPENING DIMENSIONS ARE TO THE ROUGH OPENING.
10 INTERIOR PARTITIONS ARE DIMENSIONED TO THE FACE OF STUD AND DO NOT INCLUDE WALL
FINISHES.
11 INSTALL VERTICAL CONTROL JOINTS IN GYP. BD. WHERE WALL LENGTH EXCEEDS 30 FEET, AT
EACH SIDES OF OPENINGS THAT DO NOT TERMINATE AT A CEILING, AT OTHER LOCATIONS
INDICATED, AND IN ACCORDANCE WITH GA-216.
12 DOOR JAMBS TO BE 6" FROM ADJACENT WALL.
13 PROVIDE A MINIMUM OF 18" CLEAR FLOOR SPACE BETWEEN THE FACE OF THE STRIKE JAMB OF
DOORS ADJACENT TO PERPENDICULAR WALLS. THIS REQUIREMENT DOES NOT APPLY TO
NON-ACCESSIBLE TOILET STALLS.
14 FINISH FLOOR ELEVATIONS NOTED ARE TAKEN FROM THE TOP OF STRUCTURAL CONCRETE.
15 REF. FINISH PLANS FOR EXTENT OF SPECIAL FINISHES AND FLOOR FINISH PATTERNS.
16 PROVIDE APPROPRIATE FIRESTOPPING ASSEMBLIES AT ALL PENETRATIONS OF RATED WALL
AND FLOOR ASSEMBLIES.
17 PROVIDE FIRE RETARDANT BLOCKING IN WALL AS REQUIRED FOR WALL MOUNTED TOILET
FIXTURES, ACCESSORIES, CASEWORK / MILLWORK, SHELVING, EQUIPMENT AND SIGNAGE.
18 ALL WOOD BLOCKING CONCEALED WITHIN THE BUILDING CONSTRUCTION SHALL BE FIRE
RETARDANT.
19 PROVIDE AND INSTALL 8' HIGH FIRE-RETARDANT PLYWOOD ON ALL WALLS IN THE MDF, IDF, AND ELECTRICAL ROOMS, U.N.O.
GENERAL NOTES:
SHEET NOTES:
1 FURNITURE BY OWNER
2 NEW WOOD FRAMED CASED OPENING, SEE FINISH SCHEDULE
3 RESTORE MASONRY FACADE: REMOVE EXISTING PLASTER AND PAINT. TUCK POINT MASONRY
FOR STRUCTURAL INTEGRITY AS REQUIRED
4 WATER HEATER OVER MOP SINK, REF: PLUMBING
5 BOBRICK B-239 UTILITY SHELF WITH RAG HOOKS AND BROOM HOLDERS
6 SEMI-RECESSED FIRE EXTINGUISHER CABINET, JL INDUSTRIES AMBASSADOR 1017V10
7 ELECTRICAL PANEL, REF: ELECTRICAL
8 TV BY OWNER, CONFIRM LOCATION AND MOUNTING HEIGHT WITH OWNER AND ARCHITECT
BEFORE INSTALLATION
9 REFRIGERATOR BY OWNER
10 NEW WINDOWS, REF A-631
11 NEW FRONT DOOR AND WINDOWS, REF A-631
12 OFFSET OUTLETS TO PREVENT SOUND LEAKS
13 EXTEND ALL CONFERENCE ROOM WALLS TO UNDERSIDE OF FLOOR DECK ABOVE. WALLS MUST
REACH MINIMUM STC 50.
SCALE: 3/16" = 1'-0"
ARCHITECTURAL FLOOR PLAN - FIRST FLOOR
SCALE: 3/16" = 1'-0"
ARCHITECTURAL FLOOR PLAN - SECOND FLOOR
# DATE ISSUE
1 8/11/2025 2ND FLOOR
LAYOUT
LAY-IN ACT CLG.
L7 - EXTERIOR LIGHT
L3 - LED VANITY WALL SCONCE
L4 - LED WALL SCONCE
L2 - WALL-MOUNTED LINEAR STRIP LIGHT
L1 - 2x4 TROFFER LIGHT
L5 - 6" RECESSED CAN LIGHT
GYP BOARD CLG.
5/A-3015/A-301
2/A-3012/A-301
/A
-3
/A
-3
1/A-3011/A-301
CONFERENCE
OFFICE 1
OPEN
WORKSPACE
121ENTRY
HALL
UTILITY
NOT IN
SCOPE NOT IN
SCOPE
/A
-3
/A
-3
L7
L2
L3
6' - 3 1/4"
A
A
B
B
C
C
L4
A-512
HVAC
MTL-02
PT-03
6' - 4 1/2"
5' - 3 1/8"
11' - 0 7/8"
/8
/8
11' - 0 7/8"
/4
/4
OFFICE 2
OFFICE 1
OFFICE 2
CONFERENCE
OPEN
WORKSPACE
ELEV.
SHAFT
BREAKROOM
WOMENS
RESTROOM
MENS
RESTROOM
WORK
ROOM
L1 L1 L1
L1 L1 L1
L1L1L1
L1 L1 L1
L1 L1
L1
L1 L1 L1
L1L1 L1
L1 L1 L1
L1 L1
CLG-02
9' - 6" A.F.F.
CLG-02
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
L1
L1
CPT-01
1 1
5/A-3015/A-301
2/A-3012/A-301
/A
-3
/A
-3
1/A-3011/A-301
NOT IN
SCOPE
/A
-3
/A
-3
22' - 5 1/4"
/2
A
A
B
B
C
C
7' - 9 1/4"
WOMEN'S
RESTROOM
MEN'S
RESTROOM
STORAGE
ELEV. &
MECH. RM.
6' - 0"
ELEV.
SHAFT
FLEX OFFICE
LAB
SERVER
ROOM
OFFICE
OFFICE
GREG'S
OFFICE
MEETING
ROOM
OPEN
WORKSPACE
ELEV. &
MECH. RM.
BREAKROOM
HALL
L1 L1
L1
L1
L1
L1
L1
L1
L1 L1
L1
L1L1
L1L1
L1L1
L1
L1
L1L1
L1 L1
L1
L1
CLG-03
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
CLG-01
9' - 6" A.F.F.
L5
L5
CLG-02
9' - 6" A.F.F. CLG-02
9' - 6" A.F.F.
1 HR FIRE RATED
CEILING ASSEMBLY
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
PROJECT
NORTH
TRUE
NORTH
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
A-111
REFLECTED CEILING
PLANS
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
1 ARCHITECTURAL REFLECTED CEILING PLAN(S) AND ELECTRICAL PLAN(S) SHALL BE CONSIDERED
AS ONE. ANY DESCREPANCIES BETWEEN THE TWO DISCIPLINES SHALL BE PRICED / BID BASED
ON THE PLAN WITH THE HIGHEST QUANTITY AND / OR QUALITY.
2 PRIOR TO ROUGH-IN, CONTRACTOR TO COORDINATE WITH ARCHITECT SPECIFIC LOCATIONS
OF ALL WALL- AND CEILING-MOUNTED MECHANICAL, ELECTRICAL, PLUMBING, LIFE SAFETY,
SECURITY AND AUDIO VISUAL DEVICES.
3 REF. MEP FOR DESIGN OF THESE SYSTEMS (HVAC, CIRCUITING, LIGHTING, SPRINKLERS, ETC.)
4 VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, DUCTS, STRUCTURAL
ELEMENTS, AND OTHER APPLICABLE ITEMS. ARRANGE AND MODIFY NON-VIABLE ITEMS TO
ENSURE ADEQUATE CLEARANCE FOR CEILING LAYOUT AS SHOWN.
5 PROVIDE UNISTRUT METAL FRAMING SYSTEM AND CHAIN SECURED TO STEEL STRUCTURE AS
REQUIRED FOR CEILING MOUNTED LIGHTING, FIRE ALARM DEVICES AND EQUIPMENT IN AREAS
WHERE FINISHED CEILING IS EXPOSED (OPEN TO STRUCTURE).
6 CEILINGS AND OTHER SUSPENDED ITEMS SHALL BE ATTACHED TO STRUCTURE BY FULLY
EMBEDDED OR 'SHEAR' CONNECTION. PULL OUT CONNECTIONS ARE NOT ACCEPTABLE.
7 MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF ACT TO BALANCE BORDER WIDTHS
AT OPPOSITE SIDES OF THE ROOM. BORDER WIDTHS SHOULD BE >1/2 TILE, U.N.O.
8 ALL GYB. BD. CEILINGS SHALL BE 5/8" TYPE'X' GYPSUM BOARD ON SUSPENDED LIGHT-GAUGE
FRAMING PER THE SPECIFICATIONS.
9 REFER TO ELECTRICAL DRAWINGS FOR LIGHTING AND LIFE SAFETY EQUIPMENT
10 LIGHT FIXTURES AND DEVICES TO BE CENTERED AS INDICATED.
11 ALL LIGHT SWITCHES SHALL BE LOCATED 48" TO CENTERLINE ABOVE FINISH FLOOR AND BE
LOCATED 6" FROM STRIKE SIDE OF DOOR, U.N.O. COORDINATE WITH ELECTRICAL DRAWINGS.
12 ALL THERMOSTRATS SHALL BE LOCATED 48" TO CENTERLINE ABOVE FINISH FLOOR. QUANTITY
AND APPROXIMATE LOCATION OF THERMOSTATS SHALL BE DETERMINED BY MECHANICAL
ENGINEER. LOCATIONS SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW AND APPROVAL
PRIOR TO INSTALLATION. WHERE LIGHT SWITHC AND THERMOSTATS ARE ADJACENT, INSTALL
BOTH ALIGNED HORIZONTALLY AT CENTERLINE. COORDINATE WITH MECHANICAL ENGINEER
13 FIRE SPRINKLER CONTRACTOR SHALL REFERENCE ALL DRAWINGS AND SPECIFICATIONS TO
DETERMINE PROPER COVERAGE AND SPRINKLER HEAD LAYOUT / DESIGN.
14 FINAL SPRINKLER HEAD LOCATIONS SHALL BE SET BY ENGINEER AND COORDINATED WITH
ARCHITECT. CENTER HEADS IN ACOUSTICAL TILE OR CEILING PANELS, U.N.O.
15 PROVIDE CONTINUOUS SOUND BATT INSULATION ABOVE ALL TOILET ROOM CEILINGS.
16 CEILING / SOFFIT HEIGHTS ARE NOTED ON THE REFLECTED CEILING PLANS. HEIGHTS ARE ABOVE
FINISH FLOOR.
17 REF. INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION ABOUT CEILING HEIGHTS,
MATERIALS, AND SPECIAL CONDITIONS.
18 ALL GYP. BD. CEILINGS AND SOFFITS TO BE PT-01, U.N.O. REF. DETAILS FOR ADDITIONAL
INFORMATION.
19 EXPOSED (OPEN TO STRUCTURE) SURFACES TO BE PAINTED AS SCHEDULED.
GENERAL NOTES:
RCP LEGEND:
SHEET NOTES:
1 CENTER LIGHT IN CEILING
1 FURNITURE BY OWNER
3 NO CEILING. OPEN TO STRUCTURE ABOVE
4 PROVIDE BATT INSULATION ABOVE CEILING
5 INTERIOR WALL-TO-CEILING TRANSITION, REF: TRANSITION SCHEDULE
6 REF: MEP FOR DUCT RUNS, SIZING, AND REGISTER LOCATIONS
SCALE: 3/16" = 1'-0"
ARCHITECTURAL REFLECTED CEILING PLAN - FIRST FLOOR
SCALE: 3/16" = 1'-0"
ARCHITECTURAL REFLECTED CEILING PLAN - SECOND FLOOR
EXPANSION JOINTS AND INTERIOR TRANSITIONS
EXTERIOR
ROOF EXPANSION JOINT: INPRO 672 SERIES (G01) ROOF TO ROOF
WALL-TO-WALL 1200 SERIES FOAM SEAL
INTERIOR
WALL-TO-WALL INPRO 101 SERIES RECESS MOUNT A07
(A09 PER WALL TO CORNER CONDITION)
WALL-TO-CEILING INPRO 101 SERIES RECESS MOUNT A09
FLOOR-TO-FLOOR INPRO 105 SERIES SURFACE MOUNT A01
FLOOR-TO-WALL INPRO 105 SERIES SURFACE MOUNT A02
TRANSITIONS SCHEDULE
# DATE ISSUE
OPEN
WORKSPACE
ENTRY
HALL
OFFICE 1
CONFERENCE
WORK
ROOM
BREAKROOM
UTILITY
B: RB-01
F: CPT-01
PT-01
P T -0
PT-01
P T -0
P T -0
NOT IN
SCOPE
NOT IN
SCOPE
UP
A-431
ELEV.
SHAFT
WOMENS
RESTROOM
A
A
B
B
C
C
C O
N C
-0
C O
N C
-0
B: RB-01
F: CPT-01
B: RB-01 (NONE AT
EXISTING MAS. WALL)
F: CPT-01
B: RB-01
F: CPT-01
OFFICE 2
P T -0
MENS
RESTROOM
131F: CONC - 02F: CONC - 02
F: CONC - 01
NOT IN
SCOPE
NOT IN
SCOPE
ELEV.
SHAFT
A
A
B
B
C
C
B: RB-01
F: CPT-01
B: RB-01
F: CPT-01
B: RB-01
F: CPT-01
B: RB-01
F: CPT-01
B: RB-01
F: CPT-01
B: RB-01
F: CPT-01
B: RB-01
F: CPT-01
B: RB-01
F: CPT-01
B: RB-01
F: CPT-01
B: RB-01
F: CPT-01
F: CONC - 02
F: CONC - 01
F: CONC - 02
OPEN
WORKSPACE
BREAKROOM
WOMEN'S
RESTROOM
MEN'S
RESTROOM
ELEV. &
MECH. RM.
STORAGE
FLEX OFFICE
LAB
SERVER
ROOM
OFFICE
OFFICE
MEETING
ROOM
GREG'S
OFFICE
W: XX-XX
B: XX-XX
F: XX-XX
GENERAL ROOM FINISHES:
WALL, BASE, FLOOR.
XX-XX
SPECIFIC WALL FINISH
X/X-X-XX
REFERENCE ELEVATION
FOR FINISH
CPT-01
CONC-01
FLOOR TRANSITION, RE: A-131
CONC-02
CARPET TO BE 1/8" HIGHER THAN
TRANSITION STRIP
TRANSITION STRIP, SCHLUTER
SCHIENE,
SATIN ANODIZED ALUMINUM
GROUT
THINSET MORTAR
CERAMIC TILE
FLOOR LEVELING COMPOUND,
EXTEND OUT 4'-0"
CARPET
TRANSITION STRIP, SCHLUTER
RENO RAMP K,
SATON ANODIZED ALUMINUM
CONCRETE
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
PROJECT
NORTH
TRUE
NORTH
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
A-131
FINISH PLANS
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
1 INFORMATION SHOWN ON G-501 & G-502 GOVERNS OVER ANY INFORMATION SHOWN ON
THIS SHEET. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCY BETWEEN THE
INFORMATION ON THIS SHEET AND THE INFORMATION SHOWN ON SHEET G-501 & G-502.
2 REF. ELEVATIONS FOR ADDITIONAL FINISH INFORMATION.
3 REF. FINISH SELECTIONS FOR MATERIALS AND FINISH DESIGNATIONS.
4 PREPARE SLAB AS REQUIRED PER FLOOR FINISH MANUFACTURER INSTRUCTIONS.
5 ALL WALLS AND COLUMNS TO BE PT-01, U.N.O.
6 BEGIN PAINTING FROM WALL EDGES AND CORNERS, U.N.O.
7 PROVIDE CLEAN TRANSITION IF PAINT ENDS AT OUTSIDE CORNER.
8 ALL FINISH FLOORS TO BE CPT-01, U.N.O.
9 CENTER FLOORING IN ROOM, U.N.O.
10 ALL MATERIAL CHANGES / TRANSITIONS TO OCCUR UNDER CENTERLINE OF DOOR, U.N.O.
11 DO NOT USE RUBBER TRANSITION STRIPS.
12 ALL SCHLUTER TRANSITION STRIPS TO BE ANODIZED ALUMINUM, U.N.O.
13 GROUT JOINTS ON FLOOR TO BE 1/8" WIDE, U.N.O. GROUT JOINTS ON WALL TILE TO BE 1/8"
WIDE, U.N.O. NOTIFY ARCHITECT IF MANUFACTURER'S RECOMMENDED INSTALLATION
INSTRUCTIONS DIFFER.
14 ALIGN GROUT JOINTS IN FLOOR TILE, WALL TILE AND TILE BASE, U.N.O.
15 PROVIDE CRACK ISOLATION MEMBRANE UNDER TILE AT ALL TILE FLOORING LOCATIONS ABOVE
GRADE. LATICRETE FRACTURE BAN SC OR ARCHITECT APPROVAL EQUAL.
16 PROVIDE ATTIC STOCK FOR EACH FLOORING MATERIAL AND PAINT COLOR.
17 ALL OUTLET AND LIGHT SWITCH COLORS TO BE STANDARD WHITE, U.N.O.
18 REF. DOOR & HARDWARE SCHEDULE FOR DOOR AND FRAME FINISHES.
19 ALL WALL BASE TO BE RB-01, U.N.O.
GENERAL NOTES:
SCALE: 3/16" = 1'-0"
FINISH PLAN - FIRST FLOOR
SCALE: 3/16" = 1'-0"
FINISH PLAN - SECOND FLOOR
LEGEND:
SCALE: 6" = 1'-0"
CARPET/ TILE
SCALE: 6" = 1'-0"
CARPET/ CONCRETE
# DATE ISSUE
01 FIRST FLOOR
0"
02 SECOND FLOOR
12' - 8"
04 T.O. EXIST. PARAPET
26' - 6"
/A
-3
/A
-3
NOT IN
SCOPENOT IN
SCOPE
/A
-3
AA01
A B C
T.O. STEEL
23' - 8"
MTL-02
CONC-01
MAS-EXIST
MAS-EXIST
PT-03
A-201
B B
B
01 FIRST FLOOR
0"
02 SECOND FLOOR
12' - 8"
/A
-3
/A
-3
NOT IN
SCOPE
NOT IN
SCOPE
/A
-3
D
C C
26 56 00.01
ABC
C L
T.O. STEEL
23' - 8"
MAS-01
MTL-02
MTL-04
01 FIRST FLOOR
0"
01 FIRST FLOOR
0"
02 SECOND FLOOR
12' - 8"
02 SECOND FLOOR
12' - 8"
04 T.O. EXIST. PARAPET
26' - 6"
/A
-3
/A
-3
/A
-3
/A
-3
/A
-3
/A
-3
1 2 4 5 6 7
CLCLCL
31' - 0" 30' - 0"
T.O. STEEL
23' - 8"
MAS-01 PT-02
MTL-01
MTL-03
6"
12"
3"
12"
MTL-04
(VERIFY SLOPE OF ADJ
AWNING IN FIELD)
PT-0X SEE FINISH SCHEDULE FOR PAINT SELECTIONS
MAS-01 LIMESTONE, REFER TO FINISH SCHEDULE
MTL-02 STANDING SEAM METAL ROOF, RE: ROOF PLAN
MTL-01 DOUBLE RIB METAL ROOF AWNING, RE: ROOF PLAN
MTL-03 METAL WALL PANEL
MTL-04 METAL COPING
RESTORE EXISTING MASONRY FACADE: REMOVE EXISTING PLASTER
MAS-EXIST AND PAINT, TUCK POINT MASONRY FOR STRUCTURAL INTEGRITY AS
REQUIRED
1"1"
/4
/4
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
A-201
EXTERIOR
ELEVATIONS
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
GENERAL NOTES:
KEYED NOTES:
26 56 00.01 EXTERIOR WALL MOUNTED LIGHT FIXTURE, RE: ELECTRICAL FOR FIXTURE TYPE
1 REFER TO SHEET A-6-11 FOR DOOR SCHEDULE.
2 REFER TO SHEET A-6-31 FOR STOREFRONT SCHEDULE.
3 REFER TO SHEET G-6-01 FOR FINISH SCHEDULE.
4 EXPOSED EXTERIOR STEEL TO BE PRIMED AND PAINTED AS SCHEDULED.
5 WHERE INDICATED ON DRAWINGS PROVIDE EXPANSION JOINTS AT THE FOLLOWING
LOCATIONS:
- AT SHELF ANGLES
- EVERY 30 FEET (MAXIMUM) ALONG WALLS
- AT OFFSETS IN WALLS
- AT INTERSECTIONS OF WALLS
- WHERE SHORT RUNS OF MASONRY INTERFACE WITH LONG RUNS OF MASONRY
- NEAR CORNERS (15 FEET MAXIMUM)
- AT COLUMNS
- AT FOUNDATIONS (BOND BREAK)
- AT FLOOR OR ROOF CONNECTION
- AT PARAPET WALLS
- WHERE MATERIALS WITH DIFFERENCE COEFFICIENTS OF THERMAL EXPANSION ARE JOINED
SHEET NOTES:
1 RESTORE BOTH SIDES OF MASONRY FACADE: REMOVE EXISTING PLASTER AND PAINT. TUCK
POINT MASONRY FOR STRUCTURAL INTEGRITY AS REQUIRED
2 RESTORED MASONRY LINTELS, SILLS AND CORNICES - REMOVE EXISTING PLASTER AND PAINT.
TUCK POINT MASONRY FOR STRUCTURAL INTEGRITY, AS REQUIRED
3 MATCH THE SPACING OF EXISTING BRACKET TO ADJACENT DOOR/WINDOW
4 DOUBLE RIB METAL ROOF [MTL-01] OVER STEEL TUBE AWNING BRACKETS WELDED TO BASE
PLATE ANCHORED TO STONE WALL, REF: STRUCTURAL. REFERENCE ADJACENT ANNEX BUILDING
FOR STEEL TUBE DIMENSION, PNT BLACK TO MATCH
5 EMSEAL 25V MASONRY CAVITY WALL EXPANSION JOINT, INSTALL PER MANUFACTURER'S
RECOMMENDATIONS
SCALE: 3/16" = 1'-0"
FRONT ELEVATION
SCALE: 3/16" = 1'-0"
REAR ELEVATION
SCALE: 3/16" = 1'-0"
PARTIAL ELEVATION
MATERIAL LEGEND:
SCALE: 1" = 1'-0"
CORNICE ELEVATION
# DATE ISSUE
PT-01
PT-01
PT-01
C L
RB-01
PT-01
CL
EQEQ
M O
U N
T
IN
G H
E
IG
H T
C L
PT-01
75" T.V.
RB-01
WD-01
PLENUM
OPEN TO
BEYOND
M A
X
PLAM-01
PLAM-01PLAM-01
PLAM-02
/A
-5
/A
-5
L4
B .O
. S U
P P
LY
G
R
IL
LE
WD-01
WD-01
4' - 0"
RB-01
PT-01
11' - 7 5/8"
RB-01
PLENUM PLENUM
L3
TA.5
TA.1
TA.2
TA.7
C L
M A
X . 5
TA.2
TA.3
TA.5
TA.1
PT-02
C L
TA.4
PT-02
TR-01
TL-02
TA.8
PT-02
TR-01
TL-02
L3
TA.5
TA.7
CL
EQ EQ
"5
OPEN TO
BEYOND
REF.
2" 1' - 6" 3' - 0" 3' - 0"
2" 1' - 6" 3' - 0" 3' - 0" 3' - 0"
/A
-5
/A
-5
/A
-5
/A
-5
PT-01
/A
-5
CL
1' - 6" 1' - 6"
10' - 8"
RB-01
PLAM-02PLAM-01 PLAM-01
PLENUM
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
A-221
INTERIOR
ELEVATIONS
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
SCALE: 1/2" = 1'-0"
CONFERENCE, OFFICES, AND OPEN WORKSPACES
SCALE: 1/2" = 1'-0"
CONFERENCE
SCALE: 1/2" = 1'-0"
CONFERENCE AND BREAKROOM
SCALE: 1/2" = 1'-0"
RESTROOM - NORTH ELEVATION
SCALE: 1/2" = 1'-0"
RESTROOM - EAST ELEVATION
SCALE: 1/2" = 1'-0"
RESTROOM - SOUTH ELEVATION
SCALE: 1/2" = 1'-0"
RESTROOM - WEST ELEVATION
SCALE: 1/2" = 1'-0"
BREAKROOM
1 REFER TO ACCESSIBILITY GUIDELINES G-501 AND G-502 FOR TOILET ACCESSORY MOUNTING
HEIGHTS AND CLEARANCES.
GENERAL NOTES:
1 SANITARY NAPKIN DISPOSAL ONLY IN WOMEN'S RESTROOM
2 DEMOLISH NOTCH IN EXISTING LIMESTONE WALL TO ALLOW FOR PASSAGE OF HVAC DUCTING
3 PROVIDE DUCT COLLAR TRIM FOR DUCT PENETRATIONS IN INTERIOR WALLS
SHEET NOTES:
# DATE ISSUE
02 SECOND FLOOR
12' - 8"
04 T.O. EXIST. PARAPET
26' - 6"
/A
-3
/A
-3
/A
-3
/A
-3
/A
-3
/A
-3
ENTRY
BREAKROOM
HALL
124567
T.O. STEEL
23' - 8"
FCU
A-511
01 FIRST FLOOR
0"
02 SECOND FLOOR
12' - 8"
04 T.O. EXIST. PARAPET
26' - 6"
/A
-3
/A
-3
CONFERENCE
V .I.
F.
A B C
T.O. STEEL
23' - 8"
1" / 12"
PT-02
A-511
/A
-5
A-511
A-511
OPEN
WORKSPACE
ELEV. &
MECH. RM.
HALL
WORK
ROOM
01 FIRST FLOOR
0"
02 SECOND FLOOR
12' - 8"
04 T.O. EXIST. PARAPET
26' - 6"
/A
-3
/A
-3
NOT IN
SCOPE
NOT IN
SCOPE
ELEV.
SHAFT
ELEV.
SHAFT
C
D
A B C
1" / 12"
T.O. STEEL
23' - 8"
BREAKROOM
PT-02
BREAKROOM
01 FIRST FLOOR
0"
02 SECOND FLOOR
12' - 8"
04 T.O. EXIST. PARAPET
26' - 6"
/A
-3
/A
-3
HALL
NOT IN
SCOPE
NOT IN
SCOPE
V .I.
F.
A B C
T.O. STEEL
23' - 8"
OPEN
WORKSPACE
1" / 12"
PT-02
A-512
/2
SERVER
ROOM
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
A-301
BUILDING SECTIONS
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
SHEET NOTES:
1 PRE-ENGINEERED ROOF TRUSS, REF: STRUCTURAL FOR MEMBER SIZING, SPACING, AND
LOCATION OF MECHANICAL UNIT CHASES
2 MECHANICAL DUCTING AND EQUIPMENT COORDINATE TRUSS OPENING REF: STRUCTURAL
AND HVAC
SCALE: 1/4" = 1'-0"
LONGITUDINAL SECTION AT HALL
SCALE: 3/16" = 1'-0"
CROSS SECTION AT CONFERENCE ROOM
SCALE: 3/16" = 1'-0"
CROSS SECTION AT BREAKROOM
SCALE: 3/16" = 1'-0"
CROSS SECTION AT STAIR LANDING
# DATE ISSUE
02 SECOND FLOOR
12' - 8"
04 T.O. EXIST. PARAPET
26' - 6"
A-511
A-511
A-511
A-511
T.O. STEEL
23' - 8"
DESIGN INTENT TO MATCH ADJACENT
BUILDING STAIR DESIGN. FINAL DESIGN &
ENGINEERING BY STAIR MANUFACTURER
01 FIRST FLOOR
0"
02 SECOND FLOOR
12' - 8"
04 T.O. EXIST. PARAPET
26' - 6"
A-511
A-511
A-511
T.O. STEEL
23' - 8"
A-511
Sim
3"
12"VERIFY AWNING SLOPES
WITH EXISTING ADJACENT
AWNING
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
A-311
WALL SECTIONS
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
SCALE: 1/2" = 1'-0"
SECTION B
SCALE: 1/2" = 1'-0"
SECTION A
# DATE ISSUE
2/A-3012/A-301
/A
-3
/A
-3
/A
-3
FD
TA.5
TA.1
TA.7
TA.2
TA.3
A6-1F
8' - 11 7/8"
CL
11 3/4"
A-221
8 6
H3-S
TA.8
A-221
CL
1' - 5 1/4"
FD
1" 9' - 1 7/8" 6' - 8 1/8"
H3-S
J6
A6
H3-S
BREAKROOM
WOMENS
RESTROOM
MENS
RESTROOM
2' - 11 1/8" 2' - 9" 1' - 0"
A-221 86
5 TA.8
TA.5
TA.1
TA.2
TA.4
TA.3
A B C
7' - 8"
A-511 ø 5' - 0"
O.H.
FUTURE
ELEVATOR SHAFT
A-512
CL
2' - 2 5/8"
CL
2' - 2 1/4"
9 9 1110
UP
4' - 2 1/4"
/2
HALL
UTILITY
/2
/2
A B
4' - 9 1/2"
A-512
A-5125
TA.9
HVAC
4 5
3' - 7 1/2"
4' - 0 3/8"
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
PROJECT
NORTH
TRUE
NORTH
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
A-401
ENLARGED PLANS
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
GENERAL NOTES:
TOILET ACCESSORIES KEY:
MARK DESCRIPTION MANUFACTURER MODEL COMMENTS
TA.1 36" STRAIGHT GRAB BAR BOBRICK B-6806X36
TA.2 42" STRAIGHT GRAB BAR BOBRICK B-6806X42
TA.3 TOILET TISSUE DISPENSER BOBRICK B-2840
TA.4 SANITARY NAPKIN DISPOSAL BOBRICK B-270
TA.5 WALL-MOUNTED SOAP
DISPENSER
BOBRICK B-2012
TA.6 24" X 36" MIRROR KOHLER K-31364 ESSENTIAL COLLECTION
TA.7 RECESSED PAPER TOWEL
DISPENSER/ WASTE
RECEPTACLE
BOBRICK B-36903
TA.8 SURFACE-MOUNTED COAT
HOOK
BOBRICK B-9542
TA.9 SHELF WITH MOP AND
BROOM HOLDERS AND
HOOKS
BOBRICK B-239 X 34
1 REFER TO SHEET A-602 FOR INTERIOR PARTITON TYPES.
2 REFER TO SHEET A-611 FOR DOOR SCHEDULE
3 REFER TO SHEET A-631 FOR WINDOW SCHEDULE
4 REFER TO SHEET G-601 FOR FINISH SCHEDULE.
5 REF. MEP FOR ITEMS REQUIRED BUT NOT SHOWN ON ARCHITECTURAL DRAWINGS. PROVIDE
LOCKABLE ACCESS PANELS AT ALL LOCATIONS INDICATED AS NEEDING ACCESS ON MEP
DRAWINGS. PROVIDE NECESSARY BLOCKING, FRAMING, ETC. FOR ACCESS PANELS.
6 DO NOT CUT ANY STRUCTURAL ELEMENT IN A MANNER THAT WILL DIMINISH THEIR
LOAD-BEARING CAPACITY. NOTIFY STRUCTURAL ENGINEER AND DO NOT PROCEED WITH ANY
STRUCTURAL CUT WITHOUT THEIR WRITTEN APPROVAL,
7 EXTERIOR WALLS ARE DIMENSIONED TO EXTERIOR FACE OF STUD OR EDGE OF SLAB. ALL
EXISTING WALLS ARE DIMENSIONED TO FAC OF FINISH. VERIFY ALL EXISTING WALL AND
WINDOW DIMENSIONS IN FIELD PRIOR TO CONSTRUCTION.
8 EXTERIOR WALLS (ABOVE GRADE) SHALL ACHIEVE A MINIMUM OF R-20 THERMAL ENVELOPE
INSULATION COMPONENT REQUIREMENTS (2015 IECC TABLE C402.1.3).
9 EXTERIOR OPENING DIMENSIONS ARE TO THE ROUGH OPENING.
10 INTERIOR PARTITIONS ARE DIMENSIONED TO THE FACE OF STUD AND DO NOT INCLUDE WALL
FINISHES.
11 INSTALL VERTICAL CONTROL JOINTS IN GYP. BD. WHERE WALL LENGTH EXCEEDS 30 FEET, AT
EACH SIDES OF OPENINGS THAT DO NOT TERMINATE AT A CEILING, AT OTHER LOCATIONS
INDICATED, AND IN ACCORDANCE WITH GA-216.
12 DOOR JAMBS TO BE 6" FROM ADJACENT WALL.
13 PROVIDE A MINIMUM OF 18" CLEAR FLOOR SPACE BETWEEN THE FACE OF THE STRIKE JAMB OF
DOORS ADJACENT TO PERPENDICULAR WALLS. THIS REQUIREMENT DOES NOT APPLY TO
NON-ACCESSIBLE TOILET STALLS.
14 FINISH FLOOR ELEVATIONS NOTED ARE TAKEN FROM THE TOP OF STRUCTURAL CONCRETE.
15 REF. FINISH PLANS FOR EXTENT OF SPECIAL FINISHES AND FLOOR FINISH PATTERNS.
16 PROVIDE APPROPRIATE FIRESTOPPING ASSEMBLIES AT ALL PENETRATIONS OF RATED WALL
AND FLOOR ASSEMBLIES.
17 PROVIDE FIRE RETARDANT BLOCKING IN WALL AS REQUIRED FOR WALL MOUNTED TOILET
FIXTURES, ACCESSORIES, CASEWORK / MILLWORK, SHELVING, EQUIPMENT AND SIGNAGE.
18 ALL WOOD BLOCKING CONCEALED WITHIN THE BUILDING CONSTRUCTION SHALL BE FIRE
RETARDANT.
19 PROVIDE AND INSTALL 8' HIGH FIRE-RETARDANT PLYWOOD ON ALL WALLS IN THE MDF, IDF, AND ELECTRICAL ROOMS, U.N.O.
SHEET NOTES:
1 INSTALL APPROPRIATE BUILDING CONTROL JOINT PER MANUFACTURER'S RECOMMENDATIONS
2 14" UPPER CABINETS
3 24" BASE CABINETS
4 WATER HEATER OVER MOP SINK, REF: PLUMBING
5 BOBRICK B-239 UTILITY SHELF WITH RAG HOOKS AND BROOM HOLDERS
6 SEMI-RECESSED FIRE EXTINGUISHER CABINET, JL INDUSTRIES AMBASSADOR 1017V10
7 ELECTRICAL PANEL, REF: ELECTRICAL
8 PROVIDE TEMPORARILY FRAMED OUT FLOOR OVER ELEVATOR PIT, FLUSH WITH FINISH FLOOR, FINISHED WITH LVT. REMOVED DURING INSTALLATION OF FUTURE ELEVATOR, REF: STRUCTURAL
9 INTERIOR FLOOR TRANSITION, REF: TRANSITION SCHEDULE
10 INTERIOR FLOOR-TO-WALL TRANSITION, REF: TRANSITION SCHEDULE
11 INTERIOR WALL-TO-WALL TRANSITION, REF: TRANSITION SCHEDULE
SCALE: 1/2" = 1'-0"
BREAKROOM & RESTROOMS - ENLARGED PLAN
SCALE: 1/2" = 1'-0"
ENLARGED STAIR PLAN
EXPANSION JOINTS AND INTERIOR TRANSITIONS
EXTERIOR
ROOF EXPANSION JOINT: INPRO 672 SERIES (G01) ROOF TO ROOF
WALL-TO-WALL 1200 SERIES FOAM SEAL
INTERIOR
WALL-TO-WALL INPRO 101 SERIES RECESS MOUNT A07
(A09 PER WALL TO CORNER CONDITION)
WALL-TO-CEILING INPRO 101 SERIES RECESS MOUNT A09
FLOOR-TO-FLOOR INPRO 105 SERIES SURFACE MOUNT A01
FLOOR-TO-WALL INPRO 105 SERIES SURFACE MOUNT A02
TRANSITIONS SCHEDULE
# DATE ISSUE
EXTERIOR INTERIOR
REF. STRUCT.
RUBBERIZED ASPHALT FLASHING
WEEP VENT
SHEET METAL FLASHING AND TRIM
CAVITY DRAINAGE MATERIAL
CONCRETE FOUNDATION, RE:
STRUCTURAL
BELOW-GRADE VAPOR BARRIER
GROUT SOLID WITH MORTAR
ADJUSTABLE MASONRY ANCHOR AT 16"
O.C. VERTICALLY; 32" O.C.
HORIZONTALLY
SELF-ADHERING WEATHERPROOF
MEMBRANE
SHEET METAL FLASHING AND TRIM
5/8" TYPE "X" GYPSUM WALLBOARD
ROOF TYPE A
SLOPE
PREFINISHED METAL COPING
FIRE-TREATED WOOD BLOCKING
FLUID-APPLIED WEATHER BARRIER
ADJUSTABLE MASONRY ANCHOR AT 16"
O.C. VERTICALLY; 32" O.C.
HORIZONTALLY
2X6 WOOD FRAMING @ 16" O.C, MAX.
R-19 BATT INSULATION
5/8" GLASS MAT SHEATHING
EXTRUDED POLYSTYRENE (XPS) RIGID
BOARD INSULATION (MIN. R-5 C.I.)
TPO BONDING ADHESIVE
SLOPE
METAL COMPOSITE WALL PANEL, RE:
EXTERIOR ELEVATIONS AND FINISH
SCHEDULE
R-25 C.I. RIGID INSULATION
EXTERIOR INTERIOR
1 1/4"
SELF-ADHERING WEATHERPROOF
MEMBRANE
SLOPE
BACKER ROD AND SEALANT BOTH SIDES
FIRE-TREATED WOOD SHIM
5/8" GLASS MAT SHEATHINGSELF-ADHERING WEATHERPROOF
MEMBRANE
FLUID-APPLIED WEATHER BARRIER
5/8" TYPE "X" GYPSUM WALLBOARD
EXTERIOR INTERIOR
CAVITY DRAINAGE MATERIAL
WEEP VENT
STEEL 'L' ANGLE PRIMED AND FINISHED
WITH PT-02, RE: STRUCTURAL
SELF-ADHERING WEATHERPROOF
MEMBRANE
BACKER ROD AND SEALANT BOTH SIDES
FIRE-TREATED WOOD SHIM
SELF-ADHERING WEATHERPROOF
MEMBRANE
FLASHING WEEP LEDGE WITH DRIP EDGE
SET IN CONTINUOUS BED OF SEALANT
5/8" TYPE "X" GYPSUM WALLBOARD
STEEL TUBE BRACKET WELDED
TO STEEL PLATE; COLOR AND
DIMENSIONS TO MATCH
EXISTING ANNEX BUILDING
AWNING
LOW HSS WELDED TO
SQUARE METAL PLATE REF:
STRUCTURAL FOR SIZE AND
ATTACHMENT DETAILS
SHEET METAL ROOFING
COUNTERFLASHING REGLET
WITH BEAD OF SEALANT,
WITH RECEIVER
PREFINISHED ROOF TO WALL FLASHING
WALL PANEL CLIP
REMOVABLE SHEET METAL
COUNTERFLASHING
02 SECOND FLOOR
12' - 8"
INTERIOR
FIXED WINDOW
SELF-ADHERING WEATHERPROOF
MEMBRANE
5/8" GLASS MAT SHEATHING
FLUID-APPLIED WEATHER BARRIER
1/2" RIGID INSULATION
1/2" PLYWOOD
PREFINISHED METAL ADHERED TO PLYWOOD
/4
3/4"
SELF-ADHERING WEATHERPROOF
MEMBRANE
WOOD SILL TO MATCH
WINDOW SYSTEM
BED OF SEALANT
PT WOOD BLOCKING, SLOPED TO DRAIN
2X6 WOOD FRAMING
5/8" TYPE "X" GYPSUM WALLBOARD
R-19 BATT INSULATION
BED OF SEALANT WITH WEEPS
PREFINISHED METAL FLASHING
BASE AS SCHEDULED
STANDING SEAM ROOF
REMOVABLE SHEET METAL
COUNTERFLASHING
CLEAT
PANEL CLIP
PREFINISHED METAL RECEIVER
EXTERIOR INTERIOR
EXISTING MASONRY
WALL TO REMAIN
SILANE/SILOXANE
PENETRATING SEALER
BACKER ROD
SHIM AS REQUIRED PER MFR.
RECOMMENDATIONS
BEAD OF JOINT SEALANT PER
MFR. RECOMMENDATIONS
04 T.O. EXIST. PARAPET
26' - 6"
1"1"1"
REFER TO STRUCTURAL FOR
BRACE FRAME ATTACHMENT TO
ROOF DETAILS, SEAL ALL
PENETRATIONS
GLASS-FIBER-REINFORCED CONCRETE
FRIEZE, ANCHOR TO STUD BACKUP
WALL AND SEAL PENETRATIONS WITH
COMPATIBLE SEALANT PER
MANUFACTURER RECOMMENDATIONS
TERMINATE HEMMED EDGE
FLASHING AT FACE OF WALL,
INSTALL BEAD OF SEALANT
BELOW
REFER TO STRUCTURAL FOR
FRAMING CONNECTION TO
EXISTING MASONRY WALL
R-25 C.I. RIGID INSULATION
COVER BOARD
5/8" PLYWOOD
2 3/4" ROD & 4 3/4" PINTLE
5/8" GYPSUM WALLBOARD
INPRO 1200 FOAM SEAL,
SILICONE CAULK COLOR TO
MATCH SEALANT
EXISTING LIMESTONE MASS
MASONRY WALL
NEW LIMESTONE WALL, REF:
MAS-01 IN FINISH SCHEDULE
WEATHER-RESISTIVE BARRIER
5/8" GYPSUM SHEATHING
FINISHES PER FINISH PLANS
A-131 AND A-431
5/8" EXTERIOR GRADE PLYWOOD
5/8" EXTERIOR GRADE PLYWOOD
6" X 6" RECTANGULAR GUTTER
REMOVE EXISTING TPO ROOF
OVER MASONRY WALL, PROVIDE
FIRE TREATED WOOD BLOCKING
WITH PREFINISHED METAL
COPING CAP
REF: STRUCTURAL FOR TRUSS
BLOCKING/BRACING
RIGID INSULATION INFILL
SYNTHETIC UNDERLAYMENT
(1) 1 3/4" X 16" LVL
PAINT LVL AND UNDERSIDE OF
SHEATHING, COLOR SELECTION TBD
5/8" QUIET ROCK
SEAL ALL CRACKS AND JOINTS
BETWEEN FRAMING AND GYP BD.
6" ROCKWOOL SAFE'N'SOUND
STONE WOOL INSULATION
2X2 BLOCKING
T&G DECKING
3/4" SUBFLOOR
1/4" CARPET UNDERLAYMENT
CARPET, REF: FINISH PLAN
C
OPEN CELL SPRAY FOAM BOTH
SIDES OF STRUCTURE
ACOUSTICAL SEALANT AT ALL
FLOOR TO WALL JOINTS
ACOUSTICAL SEALANT
ROUND TUBE STEEL BEYOND,
REF: STRUCTURAL
LIGHT GAUGE STEEL
ASSEMBLY, REF: PLANS FOR
INTERIOR PARTITION TYPES
WOOD STUD ASSEMBLY, REF: PLANS
ROCKWOOL BATT
INSULATION, REF: DETAIL
EXISTING MASONRY WALL
02 SECOND FLOOR
12' - 8"
/A
-3
/A
-3
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
A-511
DETAILS
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
SCALE: 1 1/2" = 1'-0"
LIMESTONE BASE AT FOUNDATION
SCALE: 1 1/2" = 1'-0"
NEW PARAPET AT ROOF
SCALE: 1 1/2" = 1'-0"
OPENING SILL AT NEW WALL
SCALE: 1 1/2" = 1'-0"
OPENING HEAD AT NEW WALL
SCALE: 1 1/2" = 1'-0"
AWNING CONNECTION AT EXISTING WALL
SCALE: 1 1/2" = 1'-0"
SILL AT EXISTING MASS MASONRY WALL
SCALE: 1 1/2" = 1'-0"
HEAD AT EXISTING MASS MASONRY WALL
SCALE: 1 1/2" = 1'-0"
DETAIL - ARCHITECTURAL CONCRETE AT PARAPET
SCALE: 1 1/2" = 1'-0"
PLAN DETAIL - EXPANSION JOINT AT WALL TRANSITION
SCALE: 1 1/2" = 1'-0"
DETAIL - NEW EAVE AT EXISTING WALL
SCALE: 3" = 1'-0"
SECTION DETAIL - FLOOR ASSEMBLY
SCALE: 3" = 1'-0"
SECTION DETAIL - ACOUSTIC TREATMENT AT STRUCTURAL BEAM
SCALE: 1 1/2" = 1'-0"
SECTION DETAIL - CONFERENCE ROOM EXT WALL CEILING
# DATE ISSUE
PARTITION TYPE 'A'
BASE
FLOORING AS SCHEDULED
CEILING AS SCHEDULED
BASE AS SCHEDULED
5/8" TYPE "X" GYPSUM WALLBOARD
HEAD
CEILING
PLAN
LINE OF STRUCTURE
SEALANT
SEALANT
INCLUDE FIBERGLASS
BATT INSULATION
STUD/ MEMBER SIZE
MODIFIER
(#) = HOURS OF FIRE RATING
(S) = SOUND ISOLATION
PARTITION
PARTITION TYPE ABBREVIATION
PARTITION TYPE GRAPHIC
PARTITION TYPE
A3-1
A3-1
BASE
FLOORING AS SCHEDULED
CEILING AS SCHEDULED
BASE AS SCHEDULED
HEAD
CEILING
PLAN
LINE OF STRUCTURE
SEALANT
SEALANT
PARTITION TYPE 'H'
RESILIENT CHANNEL
RESILIENT CHANNEL,
INSTALL PER MFR. REC.
5/8" TYPE "X" GYPSUM WALLBOARD
CL
1"
EXTEND WALL TO
UNDERSIDE OF DECK
ABOVE.
LVL JOISTS, REF. STRUCTURAL
5/8" TYPE "X" GYPSUM
WALLBOARD (2 LAYERS)
BASE
FLOORING AS SCHEDULED
CEILING AS SCHEDULED
BASE AS SCHEDULED
HEAD
CEILING
PLAN
LINE OF STRUCTURE
SEALANT
SEALANT
PARTITION TYPE 'L'
RESILIENT CHANNEL
1/2" RESILIENT CHANNEL,
INSTALL PER MFR. REC.
3 5/8" STEEL STUD,
EQ20 16" O.C.5/8" TYPE "X" GYPSUM
WALLBOARD (2 LAYERS)
5/8" TYPE "X" GYPSUM
WALLBOARD (2 LAYERS)
1/2" RESILIENT CHANNEL,
INSTALL PER MFR. REC.
2X4 WOOD STUDS
16" O.C.
3 1/2" FIBERGLASS
INSULATION
5/8" TYPE "X" GYPSUM
WALLBOARD (2 LAYERS)
PARTITION TYPE 'J'
BASE
FLOORING AS SCHEDULED
CEILING AS SCHEDULED
BASE AS SCHEDULED
EXISTING WALL
OR STRUCTURE
HEAD
CEILING
PLAN
LINE OF STRUCTURE /
DECK ABOVE
SEALANT
AIR SPACE
BRACE EACH STUD
@ 4'-0" O.C. VERTICALLY
ACOUSTICAL SEALANT
OPEN-CELL SPRAY FOAM GAPS,
CRACKS AND RUBBLE IN
PARTIALLY DEMOLISHED
EXISTING MASONRY WALL.
5/8" TYPE "X" GYPSUM
WALLBOARD (2 LAYERS)
3 1/2" FIBERGLASS BATT
Project Number:
C
O N
G R
E S S A
V E N
U E
S U
IT
E
A U
S T
IN
T X
(5
-9
W W
W .L
E V
Y D
Y K
E M
A .C
O M
© 2024 LEVY DYKEMA
B U
R N
E T
C O
U N
T Y
A N
N E X
A-602
INTERIOR
PARTITION TYPES
LD10-23055
E
A S
T J
A C
K S
O N
S T
R E E T
B
U R
N E T
T X
8/11/2025
TYPE
STUD
SIZE
UL
ASSEMBLY FIRE RATING STC COMMENTS:
<varies> -- -- --
A3 3 5/8" -- -- --
A3-1F 3 1/2" U305 1 Hour Fire 34
A3-S 3 5/8" -- -- 45
A6 5 1/2" -- -- --
A6-1F 5 1/2" U305 1 Hour Fire 36
A6-S 6" -- -- 49
1 UNLESS NOTED OTHERWISE, ALL NEW INTERIOR PARTITIONS ARE TYPE 'A3'.
2 ALL GYPSUM BOARD IS 5/8" THICK, TYPE 'X'. USE WATER-RESISTANT GYPSUM BOARD AT ALL WET
LOCATIONS. USE CEMENT BACKER BOARD AT LOCATIONS SCHEDULED TO RECEIVE TILE OR OTHER
RIGID FINISHES.
3 CEILING HEIGHTS MAY VARY ON EITHER OR BOTH SIDES OF THE PARTITION. REFER TO PLANS, REFLECTED CEILING PLANS AND OR CEILING FINISH NOTES FOR CEILING HEIGHTS.
4 FLOOR TO FLOOR DIMENSIONS MAY VARY. REFER TO BUILDING SECTIONS, WALL SECTIONS, AND
OTHER CONSTRUCTION DOCUMENTS TO DETERMINE FLOOR TO FLOOR HEIGHTS.
5 PROVIDE VERTICAL CONTROL JOINTS IN ACCORDANCE WITH GA-216 IN ALL FULL HEIGHT GYPSUM
BOARD PARTITIONS.
6 UNLESS INDICATED OTHERWISE, ALL JOINTS SHALL BE TAPED AND FLOATED, INCLUDING FIRE
RATED PARTITIONS, NON RATED PARTITIONS, EXPOSED SURFACES, CONCEALED SURFACES AND
SURFACES ABOVE THE CEILING.
7 ALL STUDS ARE CONTINUOUS FROM SILL PLATE TO BOTTOM OF STRUCTURE ABOVE, UNLESS
INDICATED OTHERWISE. FILL ALL VOIDS BETWEEN THE TOP RUNNER TRACK AND THE BOTTOM OF
STRUCTURE WITH THE APPROPRIATE SEALANT OR FIRE STOPPING SYSTEM. WHERE THE DISTANCE
EXCEEDS AVAILABLE STUD LENGTHS, SUBMIT A PROPOSED SPLICE DETAIL FOR REVIEW AND
APPROVAL BEFORE INSTALLATION OF PARTITION.
8 EXTEND FURRING TO 6" ABOVE CEILING. BRACE TO STRUCTURE OR WALL AT TOP AND AT MID-SPAN
WHEN FURRING HEIGHT EXCEEDS 12'-0".
9 PARTITION TYPE REFERENCES ARE INDICATED ON THE FLOOR PLANS. WHERE AREAS THAT ARE
ENLARGED ELSEWHERE ARE REFERENCED, PARTITION TYPES ARE INDICATED ON THE ENLARGED
PLANS ONLY.
10 PARTITION TYPES DO NOT DETERMINE EXTERIOR WALL CONSTRUCTION. REFER TO WALL SECTIONS
FOR EXTERIOR WALL CONSTRUCTION.
11 DETAILED PARTITION TYPES ARE PROVIDED FOR GENERAL REFERENCE. ALL TYPES SHOWN ARE NOT
NECESSARILY USED ON THIS PROJECT. REFER TO FLOOR PLANS FOR ACTUAL PARTITION TYPES
USED.
12 WHERE ROOMS ARE SCHEDULED WITHOUT CEILINGS, PARTITIONS SHALL EXTEND TO STRUCTURE
ABOVE UNLESS NOTED OTHERWISE.
13 PENETRATIONS THROUGH PARTITIONS BY PIPES, CONDUIT, OR OTHER RIGID MEMBERS…