About this file

This document is the Attachment F Specifications for Repair Parts for Teledyne Air Monitors for Solicitation Number: 582-24-02706 issued by the Texas Commission on Environmental Quality (TCEQ). The TCEQ repairs Teledyne air monitoring instruments installed in its air monitoring network to monitor criteria and other pollutants. The solicitation lists numerous specific Teledyne parts required for the maintenance and repair of these malfunctioning instruments, including assemblies, boards, lamps, pumps, and kits. The parts must meet or exceed the minimum specifications provided.

The solicitation does not provide details on quantities, response due dates, award dates, or contract term. However, it is related to a state and local contract opportunity for Teledyne equipment and parts to continue operating stationary air monitoring sites in Texas to meet federal requirements.

View the file

Other files

File Type Posted
ESBD_370407_1722528717355_582-24-02706 Attachment F.pdf PDF
ESBD_370407_1722528604326_RFB 582-24-02706 Non-Fillable Form.pdf PDF
ESBD_370407_1722528620382_582-24-02706 Attachment A.pdf PDF
ESBD_370407_1722528738846_TCEQ RFB Terms and Conditions Final 6-22-2023.pdf PDF
ESBD_370407_1722528639799_582-24-02706 Attachment B.pdf PDF
ESBD_370407_1722528699916_582-24-02706 Attachment E.pdf PDF
ESBD_370407_1722528563785_RFB 582-24-02706 Fillable Form.pdf PDF
ESBD_370407_1722528679153_582-24-02706 Attachment D.pdf PDF
ESBD_370407_1722528662858_582-24-02706 Attachment C.pdf PDF
ESBD_370407_1722528604326_RFB 582-24-02706 Non-Fillable Form.pdf PDF
ESBD_370407_1722528620382_582-24-02706 Attachment A.pdf PDF
ESBD_370407_1722528738846_TCEQ RFB Terms and Conditions Final 6-22-2023.pdf PDF
ESBD_370407_1722528639799_582-24-02706 Attachment B.pdf PDF
ESBD_370407_1722528717355_582-24-02706 Attachment F.pdf PDF
ESBD_370407_1722528662858_582-24-02706 Attachment C.pdf PDF
ESBD_370407_1722528699916_582-24-02706 Attachment E.pdf PDF
ESBD_370407_1722528679153_582-24-02706 Attachment D.pdf PDF
ESBD_370407_1722528563785_RFB 582-24-02706 Fillable Form.pdf PDF
ESBD_370407_1722528738846_TCEQ RFB Terms and Conditions Final 6-22-2023.pdf PDF
ESBD_370407_1722528662858_582-24-02706 Attachment C.pdf PDF
ESBD_370407_1722528639799_582-24-02706 Attachment B.pdf PDF
ESBD_370407_1722528699916_582-24-02706 Attachment E.pdf PDF
ESBD_370407_1722528604326_RFB 582-24-02706 Non-Fillable Form.pdf PDF
ESBD_370407_1722528679153_582-24-02706 Attachment D.pdf PDF
ESBD_370407_1722528563785_RFB 582-24-02706 Fillable Form.pdf PDF
ESBD_370407_1722528620382_582-24-02706 Attachment A.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation Number: 582-24-02706

Attachment F

Specifications for Repair Parts for Teledyne Air Monitors

Description: The Texas Commission on Environmental Quality repairs Teledyne air monitoring instruments that have been installed in TCEQ Air Monitoring Network to monitor criteria and other pollutants. When these monitors fail due to extended use, they are returned to the main TCEQ office for maintenance and repair. Numerous parts are required to repair the different models of malfunctioning instruments. These specifications refer to the specific Teledyne parts required for maintenance and repair.

MINIMUM GENERAL SPECIFICATIONS

1. The following components are required for monitor maintenance:

a. Assembly, Ozone Generator Lamp (BIR) (OP5) {EP}, For T400 and T700, 400E and 700E Teledyne Part #006120100 or equivalent.

b. Assembly, PMT, USED ON MODELS T100, T102, T108, T100H Teledyne part#011440100 or equivalent.

c. Assembly, Molycon, w/O3 Dest, e-series, For T200, T200U, and E-Series equivalent, Teledyne Part Number 018720200 or equivalent.

d. Rear panel fan assembly used for Rear Panel Fan Assembly used for T750U, T750, T703U, T703, T700U, T700, T802, T400, T265, T360M, T360, T300U, T300M, T300, T500U, T204, T201, T200UP, T200U NOx, T200U NOy, T200P, T200M, T200H, T200, T108U, T108, T102, T101, T100U, T100H, and T100 Teledyne part#040010000 or equivalent.

e. Photomultiplier tube Preamplifier, SOx, for use in T100, T100H, T101, T102, and T108 Teledyne Part #041800400 or equivalent.

f. PUMP ASSEMBLY WITH 13" LEADS, 12 volts, single head, For T700 and T700U, Teledyne Part Number 047020200 or equivalent.

g. Assembly, Bench Ultraviolet (UV) Lamp, (BIR) CR {GM}, For 400E and T400, Teledyne Part #052400000 or equivalent.

h. Valve driver board PRINTED CIRCUIT ASSEMBLY used for T700U and T700 Teledyne part #054690000 or equivalent.

I. PRINTED CIRCUIT ASSEMBLY, PNEUMATIC SENSOR BOARD ASSEMBLY, 15PA, 1LPM,

(CO/O3) used for T300, T300M, T360, T360M, T400, T802 Teledyne part#073210400 or equivalent.

i. PRINTED CIRCUIT ASSEMBLY, PNEUMATIC SENSOR BOARD ASSEMBLY, 15A, 15PA, 1LPM, (PA), For T200, T200U, Teledyne Part Number 073210800 or equivalent.

j. LCD Module with touch screen used for: N500, T100, T100H, T100U, T101, T102, T108, T108U, T200, T200H, T200M, T200P, T200U NOx, T200U NOy, T200UP, T201, T204, T265, T300, T300M, T300U, T360, T360M, T400, T500U, T700, T700U, T703, T750, and T802 Teledyne part#083500000 or equivalent.

k. Pneumatic Sensor Board assembly (MFC pressures) used for: T700, T700H, T700U, T750, T750U Teledyne part#084210010 or equivalent.

l. Pneumatic sensor board assembly (photometer option) used for: used for T700, T700U, T750, T750U, T703 Teledyne part #084210210 or equivalent.

m. Ozone scrubber used for T400 and N400 Teledyne Part# 096730000 or equivalent.

n. KIT, REBUILD, RX CELL, NOx, AMBIENT, For T200, Teledyne Part #KIT000051 or equivalent.

o. Assembly & TEST, SPARE PS37, For T700U, T700, T500U, T201, T200U NOy, T200U NOx, T200, T101, T100U, and T100, Teledyne Part # KIT000253 or equivalent.

p. Switching power supply, 12VDC KIT254 used for: T703U, T703, T802, T265, T500U, T204, T201, T200UP, T200U NOy, T200U NOx, T200M, T200H, T200, T108U, T108, T102, T101, T100U, T100H, and T100, Teledyne Part# KIT000254 or equivalent.

q. KIT, UV Lamp Driver, O3 GEN used on: T400, T700, T700U, T703, T703U, 750, 750U Teledyne part#KIT000289 or equivalent.

r. KIT, UV Lamp Driver, O3 Bench used on: T400, T700, T700U, T703, T703U, 750, 750U Teledyne Part# KIT000290

s. CD, PMT, SOx, (R1527) (PA), For T100, T100U, and T101, Teledyne Part #013400000 or equivalent.

t. Photo Multiplier Tube used for: T265, T200H, T200M, T200P, T200, T200UP, T200U NOy, and T200U NOx instrument Teledyne part#022890000 or equivalent.

u. PCA, PMT PreAmp, NOX, Ultra used on models: T200U NOx & T200UP Teledyne part#041800600 or equivalent.

v. PUMP PACK, DOM VOLT, W/SCRBR for T200 NOx, Teledyne Part #076510000 or equivalent.

w. Internal Pump Assembly, Universal Voltage, 6OC used for: T108, T101, T100, T400, and T102 Teledyne part#077480200 or equivalent.

x. UV Lamp with adapter used for: T108, T102, T101, T100H, and T100 Teledyne part#KIT000236 or equivalent.

Attachment F
Specifications for Repair Parts for Teledyne Air Monitors
MINIMUM GENERAL SPECIFICATIONS