Traffic Control Plans for Large Potable Water Valve Replacement Project

This document is a traffic control plan set prepared by the Long Beach Utilities Department for waterline construction activities in Long Beach, California. The project involves large potable water valve replacement at four intersection locations: Orange Avenue & East 57th Street, East Wardlow Road and Woodruff Avenue, East Stearns Street & Palo Verde Avenue, and East Stearns Street & East De Ora Way. The contract number is EO-3674, and the project is in pre-final milestone status. The plans provide detailed traffic control specifications for each work site, including lane configurations, buffer zones, work zones, shifting tapers, and temporary traffic control device placements. The contractor is required to furnish and install temporary Type-K railing per Caltrans Standard Plans T3A & T3B, 36-inch high surface-mounted tubular markers per MUTCD Chapter 6F Figure 6F-102(CA), and 36-inch high portable delineators per MUTCD Chapter 6F Figure 6F-102(CA). Portable changeable message signs (PCMS) must be programmed to display messages for two-second intervals, with different screens showing at major work streets two weeks prior to construction and during construction phases. Traffic control signs conform to the latest editions of state guidelines and the California Manual on Uniform Traffic Control Devices.

The plans specify all traffic control devices must be placed in proper positions at all times and removed upon project completion within 24 hours of damage to ensure public safety. The contractor must coordinate daily access restrictions with residents at 4900, 4902, 4908, and 4910 East Stearns Street. All work zones include traffic striping installations on designated sides of streets only, with extended buffer zones and taper lengths designed to accommodate the specific geometry of each intersection. Public safety coordination involves the Long Beach Police Department and Long Beach Transit Operations. The document is dated October 2, 2025, and is signed by B. Anatole Falagan, General Manager of the Long Beach Utilities Department, with approval recommended by the Director of Water/Sewer Engineering and Manager of Engineering.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TRAFFIC CONTROL GENERAL NOTES

1. WORKING HOURS SHALL BE 8:00AM TO 4:00PM, MONDAY THRU FRIDAY, UNLESS OTHERWISE

APPROVED BY THE CITY OF LONG BEACH, NO EXCEPTIONS.

2. ALL SIGNS, DELINEATORS, ETC. SHALL CONFORM TO THE LATEST EDITIONS OF THE STATE OF

CALIFORNIA STANDARD PLANS AND SPECIFICATIONS (LATEST EDITION), THE CALIFORNIA MANUAL

ON UNIFORM TRAFFIC CONTROL DEVICES (LATEST EDITION), THE PROJECT SPECIFICATIONS, AND

THESE PLANS.

3. ALL TRAFFIC CONTROL DEVICES SHALL BE KEPT IN THEIR PROPER POSITION AT ALL TIMES AND

SHALL BE REPAIRED, REPLACED, AND/OR CLEANED AS NECESSARY TO PRESERVE THEIR

APPEARANCE AND CONTINUITY.

4. THE ENGINEER RESERVES THE RIGHT TO OBSERVE THESE TRAFFIC CONTROL PLANS IN USE AND

MAKE ANY CHANGES NECESSITATED BY FIELD CONDITIONS. ALL SUCH CHANGES SHALL

SUPERCEDE THESE PLANS AND WILL BE DONE SOLELY AT THE CONTRACTOR'S EXPENSE

5. UPON COMPLETION OF THIS PROJECT, THE CONTRACTOR SHALL REMOVE ALL TEMPORARY TRAFFIC

CONTROL DEVICES AND RESTORE PERMANENT SIGNING AND STRIPING IMPACTED BY

CONSTRUCTION TO THEIR ORIGINAL CONDITION. CONTRACTOR RESPONSIBLE FOR THE REPAIR OF

ALL DAMAGED TRAFFIC LOOPS WITHIN 72 HOURS OF DAMAGE TO THEM.

6. ALL STRIPING, PAVEMENT MARKINGS, AND LEGENDS SHALL CONFORM TO CALTRANS STANDARD

PLANS A20A-A20D AND A24A-A24E.

7. SIGNS SHALL CONFORM TO THE CURRENT SIGN SPECIFICATIONS. SIGN SIZE SHALL BE THE

STANDARD SIZE NOTED IN THE SIGN SPECIFICATIONS UNLESS OTHERWISE NOTED IN THESE PLANS.

8. ALL TEMPORARY STRIPING, PAVEMENT MARKINGS, AND LEGENDS SHALL BE IN PAINT.

9. CONSTRUCTION OPERATIONS SHALL BE CONDUCTED IN SUCH A MANNER AS TO CAUSE AS LITTLE

INCONVENIENCE AS POSSIBLE TO ABUTTING PROPERTY OWNERS. ALL PROPERTIES THAT HAVE

ACCESS ADJACENT TO THE WORK AREA SHALL BE NOTIFIED IN WRITING 48 HOURS MINIMUM

BEFORE THE START OF WORK. THE NOTIFICATION SHALL DESCRIBE THE ACCESS LIMITATIONS, DATES OF LIMITATION, AND GIVE THE APPROXIMATE DATE AND TIME OF ACCESS RESTRICTION. NO

ACCESS SHALL BE RESTRICTED DURING NON-WORKING HOURS, EXCEPT AS APPROVED BY THE

ENGINEER.

10. TRAFFIC CONTROL SHOWN IN THESE PLANS IS INTENDED TO BE INSTALLED FOR THE DURATION OF

THE CONSTRUCTION FOR EACH SITE. I.E. 24 HOURS PER DAY.

11. TRENCHES SHALL BE BACKFILLED OR COVERED WITH STEEL TRAFFIC TRENCH PLATES DURING

NONWORKING HOURS.

12. THE FOLLOWING AGENCIES SHALL BE NOTIFIED 72 HOURS IN ADVANCE OF ANY DETOUR AND/OR

CONSTRUCTION ACTIVITIES:

PUBLIC WORKS:

CITY OF LONG BEACH (562) 570-6383

PUBLIC SAFETY:

CITY OF LONG BEACH POLICE DEPARTMENT (562) 435-6711

TRANSIT:

LONG BEACH TRANSIT (OPERATIONS) (562) 591-2301

LEGEND

SHEET INDEX

PAGE NO. SHEET DESCRIPTION

15 TC-01 TITLE SHEET

16 TC-02 ORANGE AVENUE AND EAST 57TH STREET

17 TC-03 EAST WARDLOW ROAD AND WOODRUFF AVENUE

18 TC-04 EAST STEARNS STREET & PALO VERDE AVENUE

19 TC-05 EAST STEARNS STREET & EAST DE ORA WAY

PROJECT SITE MAP

NOT TO SCALE

TRAFFIC CONTROL SIGNS

PROJECT

SITE(S)

DIRECTOR OF WATER/SEWER ENGINEERING

MANAGER OF ENGINEERING

APPROVED

RECOMMENDED

DEPARTMENT DATE

BY CK'D.

CITY ENG.

VERIZON

EDISON CO.

LB ENERGY

FIRE

INPUT BY

AS-BUILT BY

POSTED GIS

CONSTRUCTED BY

GIS TILE

SPEC. NO

SECTION MAP

SERVICE ATLAS PAGE

GATE VALVES REC.

AS SHOWN

SCALE

N/A

CONTRACT NO.

CHECKED BY

DESIGNED BY

DATE

DATE

CORRECTED BY

DATE

DATE

DATE

DATE

DATE 9/22/25

VARIOUS

DESCRIPTION

DATE

REV.

EO - 3674

DRAWING / FILE NUMBER:

DATE

DATE

B. Anatole Falagan

GENERAL MANAGER

LONG BEACH UTILITIES DEPARTMENT

LARGE POTABLE WATER VALVE

REPLACEMENT PROJECT

LLC

AGR

F I L E

N

A M

E

M c d w g

D

S

I G

N

B

Y

P R

E F

I N

M

I L

E S

T O

N E

N/A

MUNIS PROJECT:

SHEET OF SHEETSDWG.

9/22/25

HUNTINGTON BEACH

5622 RESEARCH DR, UNIT A

HUNTINGTON BEACH, CA 92649

TEL:(714)723-0401 FAX:(714)723-6220

1-855-222-T2UE | WWW.T2UE.COM

PORTABLE DELINEATOR FLASHING ARROW SIGN (FAS)

FAS SUPPORT OR TRAILER

WORK ZONE

TEMPORARY TRAFFIC

CONTROL SIGN

TYPE III BARRICADE

S

TYPE K-RAIL

TRAFFIC CONTROL PLANS

FOR WATERLINE CONSTRUCTION

AT THE INTERSECTIONS OF

ORANGE AVENUE & EAST 57TH STREET,

EAST WARDLOW ROAD AND WOODRUFF AVENUE,

EAST STEARNS STREET AND PALO VERDE AVENUE,

AND EAST STEARNS STREET AND EAST DE ORA WAY,

IN THE CITY OF LONG BEACH, CALIFORNIA TRAFFIC CONTROL CONSTRUCTION NOTES

FURNISH AND INSTALL TEMPORARY RAILING (TYPE-K) PER CALTRANS STD

PLANS T3A & T3B.

TITLE SHEET

L O

G

B

A

C H

V

D

C H

E R

R Y

V E

A T

L A

N T

E

L A

K E

W O

O

V

D

C L

A R

K

A

V E

B E

L L

F L

O W

V

D

P A

R

E

CARSON ST

ARTESIA BLVD

WARDLOW RD

SPRING ST

WILLOW ST

O R

A N

E

DEL AMO BLVD

S

T

O

N

R E

D O

N D

O

A

V E

STEARNS ST

L

S

Y

A

W O

O D

R U

F F

E

PROJECT SITE

CONTACT LONG BEACH

TRANSIT AT (562) 591-2301 72

HOURS PRIOR TO START OF

WORK FOR TEMPORARY

RELOCATION OF BUS STOP

PCMS

DIRECTION OF TRAVEL

SCREEN 1

M A J WOR K

S T R E E T

N A M E

FURNISH AND INSTALL 36-INCH HIGH SURFACE MOUNTED TUBULAR

MARKER(S) PER MUTCD, CH 6F, FIGURE 6F-102(CA), DETAIL HEREON.

FURNISH AND INSTALL PORTABLE CHANGEABLE MESSAGE SIGN (PCMS).

DISPLAY MESSAGE(S) PER HEREON.

PORTABLE CHANGEABLE MESSAGE SIGN NOTES

1. CONTRACTOR SHALL PROGRAM EACH SCREEN OF ALL PCMS TO DISPLAY

FOR TWO (2) SECONDS.

SCREEN 2

X X / X X / X X

T O

X X / X X / X X

SCREEN 2

U S E

A L T

R O U T E S

TWO (2) WEEKS PRIOR

TO CONSTRUCTION

DURING CONSTRUCTION

FURNISH AND INSTALL 36-INCH HIGH PORTABLE DELINEATOR(S) PER

MUTCD, CH 6F, FIGURE 6F-102(CA), DETAIL HEREON.

PCMS

P C

M S

P C

M S

PCMS

PCMS

PCMS

PCMS

PCMS

SCREEN 1

M A J WOR K

S T R E E T

N A M E

SIGNALIZED INTERSECTION

PORTABLE CHANGEABLE

MESSAGE SIGN

P C

M S

P C

M S

PORTABLE DELINEATOR DETAIL

3 inches Minimum

Retroreflective

Bands

Less than 42 inches;

36 inches Minimum

2 inches Maximum

3 inches

3 inches

2-6 inches

Weighted Base

NOT TO SCALE

TUBULAR MARKER DETAIL

Less than 42 inches;

28 inches Minimum

Surface Mount

NOT TO SCALE

2 inches Maximum

3 inches

3 inches

2-6 inches

Retroreflective

Bands

TUBULAR MARKER

10/2/2025

W20-3

R3-5R

G20-2

W20-1

125' SHIFTING TAPER

250' BUFFER ZONE

50' LANE

CONTROL

100' WORK ZONE125' SHIFTING TAPER

54' LANE

CONTROL

W20-3

R3-5R

G20-2

W20-1

G20-2

W20-1

9'

9'

17'

10'

PROPOSED WATERLINE

CL

R/W

CL

G20-2

W20-1

R/W

R/W

R/W

W20-1

G20-2

C20(RT)

W1-4

(LT)

W1-4(RT)

R3-2

R3-2

C30 C30

TRAFFIC STRIPING

INSTALL T.A.N.P.A.T. ON THIS SIDE OF THE STREET ONLY

PROPOSED

LINESTOP(S)

250' 250' 250'

250'

R3-5R R3-5R

R3-5R R3-5R

DIRECTOR OF WATER/SEWER ENGINEERING

MANAGER OF ENGINEERING

APPROVED

RECOMMENDED

DEPARTMENT DATE

BY CK'D.

CITY ENG.

VERIZON

EDISON CO.

LB ENERGY

FIRE

INPUT BY

AS-BUILT BY

POSTED GIS

CONSTRUCTED BY

GIS TILE

SPEC. NO

SECTION MAP

SERVICE ATLAS PAGE

GATE VALVES REC.

AS SHOWN

SCALE

N/A

CONTRACT NO.

CHECKED BY

DESIGNED BY

DATE

DATE

CORRECTED BY

DATE

DATE

DATE

DATE

DATE 9/22/25

VARIOUS

DESCRIPTION

DATE

REV.

EO - 3674

DRAWING / FILE NUMBER:

DATE

DATE

B. Anatole Falagan

GENERAL MANAGER

LONG BEACH UTILITIES DEPARTMENT

LARGE POTABLE WATER VALVE

REPLACEMENT PROJECT

LLC

AGR

F I

M

E

M c d

S

I G

N

B

Y

P R

E F

I N

L

E S

T O

N E

N/A

MUNIS PROJECT:

SHEET OF SHEETSDWG.

9/22/25

HUNTINGTON BEACH

5622 RESEARCH DR, UNIT A

HUNTINGTON BEACH, CA 92649

TEL:(714)723-0401 FAX:(714)723-6220

1-855-222-T2UE | WWW.T2UE.COM

TRAFFIC CONTROL SIGNS

E PHILLIPS ST

ORANGE AVENUE AND EAST 57TH STREET

TRAFFIC CONTROL PLAN

SCALE: 1"=40'

40' 40'20'

ORANGE AVENUE

(SPEED LIMIT = 35MPH)

E 57TH ST

E 56TH ST

TRAFFIC CONTROL CONSTRUCTION NOTES

FURNISH AND INSTALL TEMPORARY RAILING (TYPE-K) PER CALTRANS STD

PLANS T3A & T3B.

FURNISH AND INSTALL 36-INCH HIGH SURFACE MOUNTED TUBULAR

MARKER(S) PER MUTCD, CH 6F, FIGURE 6F-102(CA), DETAIL HEREON.

FURNISH AND INSTALL 36-INCH HIGH PORTABLE DELINEATOR(S) PER

MUTCD, CH 6F, FIGURE 6F-102(CA), DETAIL HEREON.

LEGEND

PORTABLE DELINEATOR FLASHING ARROW SIGN (FAS)

FAS SUPPORT OR TRAILER

WORK ZONE

TEMPORARY TRAFFIC

CONTROL SIGN

TYPE III BARRICADE

S

TYPE K-RAIL

DIRECTION OF TRAVEL

SIGNALIZED INTERSECTION

TUBULAR MARKER

72' WORK AREA100' END TAPER

INSTALL T.A.N.P.A.T. ON THIS SIDE OF THE STREET ONLY

140' WORK AREA

INSTALL T.A.N.P.A.T. ON THIS SIDE OF THE STREET ONLY

125' SHIFTING TAPER

250' BUFFER ZONE 245' MERGING TAPER

G20-2

W20-1

250' 250' 250'

250'

35'

17'

35'

G20-2

W20-1

G20-2

W20-1

G20-2

W20-1

G20-2

W20-1

W20-1

G20-2

W20-1

W20-1

G20-2

G20-2

W20-1

G20-2

R3-18

R3-5R

R3-5R

G20-2

W20-1

C20(LT)W4-2(LT)

C30C30

C30

PROPOSED

WATERLINE

PROPOSED

LINESTOP

PROPOSED

WATER LINESTOP

CL

R/W R/W

R/W

R/W

TRAFFIC STRIPING

TRAFFIC STRIPING

R4-7A

C30

DIRECTOR OF WATER/SEWER ENGINEERING

MANAGER OF ENGINEERING

APPROVED

RECOMMENDED

DEPARTMENT DATE

BY CK'D.

CITY ENG.

VERIZON

EDISON CO.

LB ENERGY

FIRE

INPUT BY

AS-BUILT BY

POSTED GIS

CONSTRUCTED BY

GIS TILE

SPEC. NO

SECTION MAP

SERVICE ATLAS PAGE

GATE VALVES REC.

AS SHOWN

SCALE

N/A

CONTRACT NO.

CHECKED BY

DESIGNED BY

DATE

DATE

CORRECTED BY

DATE

DATE

DATE

DATE

DATE 9/22/25

VARIOUS

DESCRIPTION

DATE

REV.

EO - 3674

DRAWING / FILE NUMBER:

DATE

DATE

B. Anatole Falagan

GENERAL MANAGER

LONG BEACH UTILITIES DEPARTMENT

LARGE POTABLE WATER VALVE

REPLACEMENT PROJECT

LLC

AGR

F I

M

E

M c d

S

I G

N

B

Y

P R

E F

I N

L

E S

T O

N E

N/A

MUNIS PROJECT:

SHEET OF SHEETSDWG.

9/22/25

HUNTINGTON BEACH

5622 RESEARCH DR, UNIT A

HUNTINGTON BEACH, CA 92649

TEL:(714)723-0401 FAX:(714)723-6220

1-855-222-T2UE | WWW.T2UE.COM

EAST WARDLOW ROAD AND WOODRUFF AVENUE

TRAFFIC CONTROL PLAN

TRAFFIC CONTROL SIGNS

EAST WARDLOW ROAD

(SPEED LIMIT = 35MPH)

SCALE: 1"=40'

40' 40'20'

FAUST AVEWOODRUFF AVE

S

TRAFFIC CONTROL CONSTRUCTION NOTES

FURNISH AND INSTALL TEMPORARY RAILING (TYPE-K) PER CALTRANS STD

PLANS T3A & T3B.

FURNISH AND INSTALL 36-INCH HIGH SURFACE MOUNTED TUBULAR

MARKER(S) PER MUTCD, CH 6F, FIGURE 6F-102(CA), DETAIL HEREON.

FURNISH AND INSTALL 36-INCH HIGH PORTABLE DELINEATOR(S) PER

MUTCD, CH 6F, FIGURE 6F-102(CA), DETAIL HEREON.

LEGEND

PORTABLE DELINEATOR FLASHING ARROW SIGN (FAS)

FAS SUPPORT OR TRAILER

WORK ZONE

TEMPORARY TRAFFIC

CONTROL SIGN

TYPE III BARRICADE

S

TYPE K-RAIL

DIRECTION OF TRAVEL

SIGNALIZED INTERSECTION

TUBULAR MARKER

110' WORK AREA

PROPOSED WATERLINE

' B

U

F F

E R

Z O

N

E

' S

H

IF

T

IN

G

T A

P E

R

M

E

R

G

I

T

P

E

R

W20-1

C20(RT)

W4-2(RT)

G20-2

G20-2

W20-1

G20-2

W20-1

R9-11A(RT)

R9-11A(LT)

TRAFFIC STRIPING

CL

R/W

R/W

R/W

R/W

C30

PROPOSED

LINESTOP

C30

C30

C30

C30

C30

R4-8

E

X T

E N

D E

D

B

U F

F E

R

Z

O N

E

125' SHIFTING TAPER

R3-2

R3-2

R4-7A

250'

17'

TRAFFIC STRIPING

C30

245' BUFFER ZONE

250'250'250'

390' EXTENDED BUFFER ZONE

W20-1

C20(RT)

W4-2(RT)

G20-2

W20-1

G20-2

G20-2

W20-1

35'

35'

G20-2

W20-1

TRAFFIC STRIPING

C30

C30

TRAFFIC CONTROL SIGNS

EAST STEARNS STREET

(SPEED LIMIT = 35MPH)

SCALE: 1"=40'

40' 40'20'

PALO VERDE AVE

DIRECTOR OF WATER/SEWER ENGINEERING

MANAGER OF ENGINEERING

APPROVED

RECOMMENDED

DEPARTMENT DATE

BY CK'D.

CITY ENG.

VERIZON

EDISON CO.

LB ENERGY

FIRE

INPUT BY

AS-BUILT BY

POSTED GIS

CONSTRUCTED BY

GIS TILE

SPEC. NO

SECTION MAP

SERVICE ATLAS PAGE

GATE VALVES REC.

AS SHOWN

SCALE

N/A

CONTRACT NO.

CHECKED BY

DESIGNED BY

DATE

DATE

CORRECTED BY

DATE

DATE

DATE

DATE

DATE 9/22/25

VARIOUS

DESCRIPTION

DATE

REV.

EO - 3674

DRAWING / FILE NUMBER:

DATE

DATE

B. Anatole Falagan

GENERAL MANAGER

LONG BEACH UTILITIES DEPARTMENT

LARGE POTABLE WATER VALVE

REPLACEMENT PROJECT

LLC

AGR

F I

M

E

M c d

S

I G

N

B

Y

P R

E F

I N

L

E S

T O

N E

N/A

MUNIS PROJECT:

SHEET OF SHEETSDWG.

9/22/25

HUNTINGTON BEACH

5622 RESEARCH DR, UNIT A

HUNTINGTON BEACH, CA 92649

TEL:(714)723-0401 FAX:(714)723-6220

1-855-222-T2UE | WWW.T2UE.COM

EAST STEARNS STREET & PALO VERDE AVENUE

TRAFFIC CONTROL PLAN

MATCH LINE - SEE ABOVE

M A

T C

H

L I N

E

S

L O

W

PALO VERDE AVENUE

(SPEED LIMIT = 35MPH)

WOODRUFF AVEWOODRUFF AVE

405 NORTH OFF / ON RAMP

S

SS

TRAFFIC CONTROL CONSTRUCTION NOTES

FURNISH AND INSTALL TEMPORARY RAILING (TYPE-K) PER

CALTRANS STD PLANS T3A & T3B.

FURNISH AND INSTALL 36-INCH HIGH SURFACE MOUNTED TUBULAR

MARKER(S) PER MUTCD, CH 6F, FIGURE 6F-102(CA), DETAIL HEREON.

FURNISH AND INSTALL 36-INCH HIGH PORTABLE DELINEATOR(S) PER

MUTCD, CH 6F, FIGURE 6F-102(CA), DETAIL HEREON.

LEGEND

PORTABLE DELINEATOR FLASHING ARROW SIGN (FAS)

FAS SUPPORT OR TRAILER

WORK ZONE

TEMPORARY TRAFFIC

CONTROL SIGN

TYPE III BARRICADE

S

TYPE K-RAIL

DIRECTION OF TRAVEL

SIGNALIZED INTERSECTION

TUBULAR MARKER

100' WORK ZONE250' BUFFER ZONE50' TAPER250'250'250'250' 50' TAPER 50'

250' 250' 250' 250'50'

PROPOSED WATERLINE

W3-4

G20-2

C9A

W20-4

W20-1

W3-4

G20-2

C9A

W20-4

W20-1

W3-4

G20-2

C9A

W20-4

W20-1

17'

10'

10'

17'

C30 C30 C30

W3-4

C9A

W20-4

G20-2

W20-1

INSTALL T.A.N.P.A.T. ON BOTH SIDES OF THE STREET

R/W

R/W

CL

PROPOSED LINESTOP

TRAFFIC STRIPING

R3-5R

TRAFFIC CONTROL SIGNS

EAST STEARNS STREET

(SPEED LIMIT = 35MPH)

SCALE: 1"=40'

40' 40'20'

E DE ORA WY

DIRECTOR OF WATER/SEWER ENGINEERING

MANAGER OF ENGINEERING

APPROVED

RECOMMENDED

DEPARTMENT DATE

BY CK'D.

CITY ENG.

VERIZON

EDISON CO.

LB ENERGY

FIRE

INPUT BY

AS-BUILT BY

POSTED GIS

CONSTRUCTED BY

GIS TILE

SPEC. NO

SECTION MAP

SERVICE ATLAS PAGE

GATE VALVES REC.

AS SHOWN

SCALE

N/A

CONTRACT NO.

CHECKED BY

DESIGNED BY

DATE

DATE

CORRECTED BY

DATE

DATE

DATE

DATE

DATE 9/22/25

VARIOUS

DESCRIPTION

DATE

REV.

EO - 3674

DRAWING / FILE NUMBER:

DATE

DATE

B. Anatole Falagan

GENERAL MANAGER

LONG BEACH UTILITIES DEPARTMENT

LARGE POTABLE WATER VALVE

REPLACEMENT PROJECT

LLC

AGR

F I

M

E

M c d

S

I G

N

B

Y

P R

E F

I N

L

E S

T O

N E

N/A

MUNIS PROJECT:

SHEET OF SHEETSDWG.

9/22/25

HUNTINGTON BEACH

5622 RESEARCH DR, UNIT A

HUNTINGTON BEACH, CA 92649

TEL:(714)723-0401 FAX:(714)723-6220

1-855-222-T2UE | WWW.T2UE.COM

EAST STEARNS STREET & EAST DE ORA WAY

TRAFFIC CONTROL PLAN

CONTRACTOR SHALL COORDINATE

DAILY ACCESS RESTRICTIONS WITH

THE RESIDENTS OF:

4900, 4902, 4908, & 4910

EAST STEARNS STREET

TRAFFIC CONTROL CONSTRUCTION NOTES

FURNISH AND INSTALL TEMPORARY RAILING (TYPE-K) PER CALTRANS STD

PLANS T3A & T3B.

FURNISH AND INSTALL 36-INCH HIGH SURFACE MOUNTED TUBULAR

MARKER(S) PER MUTCD, CH 6F, FIGURE 6F-102(CA), DETAIL HEREON.

FURNISH AND INSTALL 36-INCH HIGH PORTABLE DELINEATOR(S) PER

MUTCD, CH 6F, FIGURE 6F-102(CA), DETAIL HEREON.

LEGEND

PORTABLE DELINEATOR FLASHING ARROW SIGN (FAS)

FAS SUPPORT OR TRAILER

WORK ZONE

TEMPORARY TRAFFIC

CONTROL SIGN

TYPE III BARRICADE

S

TYPE K-RAIL

DIRECTION OF TRAVEL

SIGNALIZED INTERSECTION

TUBULAR MARKER

Sheets and Views
LON0290 TRAF-CONT-TC-01
LON0290 TRAF-CONT-TC-02
LON0290 TRAF-CONT-TC-03
LON0290 TRAF-CONT-TC-04
LON0290 TRAF-CONT-TC-05

File details come from the government source that posted it. Updated .