ENERGY QAP E1.11 QCPLAN.pdf

PDF 2 MB Posted

Attached to
Government Owned Contractor Operated Alongside Aircraft Refueling Services
Solicitation number
SPE60322R0504
Issued by

View the file

Other files

File Type Posted
Amendment 0010.pdf PDF
PAX River PWS (1-4-23).pdf PDF
Amendment 0009.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007.pdf PDF
Attach I PWS Update.pdf (Pax River) (5-10-22).pdf PDF
Solicitation Update 5-12-2022.pdf PDF
Amendment 0006.pdf PDF
Amendment 0005.pdf PDF
SOLICITATION SPE60322R0504 UPDATED.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003.pdf PDF
Attach I PWS Update.pdf PDF
PPQ form.pdf PDF
Amendment 0002.PDF PDF
0001 Amendment.pdf PDF
Attachment IV Consent Form.pdf PDF
Attach I PWS.pdf PDF
Attachment VI Form 19.3.pdf PDF
ENERGY QAP E30.01 DESIGNATION OF QUAL.pdf PDF
ENERGY QAP E1.01.pdf PDF
SOLICITATION SPE60322R0504.pdf PDF
ENERGY QAP E28 CON INSPECTION.pdf PDF
ENERGY QAP E29 INITIAL ON-STATION.pdf PDF
Attach VIII QASP (7-12-21).pdf PDF
Attach V CBA-WD 2021.pdf PDF
Attachment III PPQ form.pdf PDF
Attachment II PPQ References.pdf PDF
ENERGY QAP E35 (DEC 2011).pdf PDF
ENERGY QAP E22 (AUG 2020).pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PDF (DLA)DLA FORM 1889, OCT 2011

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

SHEET 1 OF 1PREVIOUS EDITION IS USABLE Add Continuation Page

Print Form Email Form Clear Export Data Import Data About Check for Newer Version Contact Us

REV DESCRIPTION DATE APPROVED

ENERGY QAP E1.11 March 2000

REVISIONS

E1.11 QUALITY CONTROL PLAN

(a) Upon award, the Contractor shall prepare, in triplicate and in English, a Quality Control Plan (QCP). Prior to the first receipt of Government-owned product into the facility, two copies of the QCP shall be forwarded to the Contracting Officer and one copy to the assigned Quality Assurance Representative for approval.

(b) The QCP shall include the following quality control procedures employed by the Contractor.

(1) Receiving (both product and additives);

(2) Blending;

(3) Sampling;

(4) Testing;

(5) Storage and handling;

(6) Loading and shipping;

(7) Calibration program for testing and measuring equipment in accordance with ISO 10012-1, "Quality Assurance Requirements for Measuring Equipment, Part I." Equivalent local regulation, as appropriate, may be used as well. Whichever program used must include a section addressing meter proving (used to determine quantity) and must comply with the American Petroleum Institute Manual of Petroleum Measurement Standards, Chapters 4, 5, and 6, or equivalent foreign standard. For any item that requires calibration but is not covered by ASTM, API, or IP publications, the applicable manufacturer's recommended calibration method(s) outlined in the applicable industry publication shall be used if acceptable to the Government;

(8) Quantity measurement;

(9) Records and reports; and

(10) Corrective action procedures (to include, but not be limited to, procedures for notification of Quality Representative, actions to be taken on discovery of off-spec product during receipts/shipments, upgrading procedures for Contractor-caused contamination, leaks, etc.). The QCP shall also include an organizational chart of key personnel and their responsibilities and a schematic diagram of the facility with key inspection/activity points marked for each product handled.

(c) The QCP shall require that each Contractor employee be familiar with its content and shall state that it must be reviewed semiannually and revised as needed. Revision should occur when any change is made to the inspection system, when any corrective action needs to be incorporated due to quality problems, and as otherwise necessary. The Contractor shall sign and date each revision of the QCP.

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

DISTRIBUTION

STATEMENT - A

APPROVED FOR

PUBLIC RELEASE

DISTRIBUTION IS

"UNLIMITED"

DATE

2013-1120

APPROVED BY

DATE

11/20/2013

REVIEWED BY

DATE

11/12/2013

PREPARED BY

DRAWING NUMBERSCALE

CODE ID NO.

52838

SIZE

NSN

MULTIPLE

ITEM

ENERGY QAP E1.11

DLA Land & Maritime DLA Troop Support DLA Aviation clear

DEFENSE ENERGY SUPPORT CENTER

8725 JOHN J. KINGMAN RD

FORT BELVOIR, VIRGINIA 22060-6222

DLA Energy

PDF (DLA)

DLA FORM 1889, OCT 2011

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

SHEET OF

PREVIOUS EDITION IS USABLE

REV

DESCRIPTION

DATE

APPROVED

REVISIONS

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

DISTRIBUTION STATEMENT - A

APPROVED FOR PUBLIC RELEASE

DISTRIBUTION IS "UNLIMITED"

REV

DESCRIPTION

DATE

APPROVED

REVISIONS

DISTRIBUTION STATEMENT - A

APPROVED FOR PUBLIC RELEASE

DISTRIBUTION IS "UNLIMITED"

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

Supplemental Quality Assurance Provision (SQAP) DSCC Form 2291, Feb 2004 online none standard Quality Assurance

DLA

1 + No Tech Qual Deskbook n/a No Supplemental Quality Assurance Provision (SQAP) interactive October 2011 (added Energy; updated supply center names)

CurrentPage:
PageCount:
btnPrint:
btnEmail:
btnClear:
btnExport:
btnImport:
btnAbout:
btnChkVersion:
btnContactUs:
Button1:
rev:
description: ENERGY QAP E1.11
revdate: March 2000
revapproved:
revcomments:
apprdate: 2013-1120
apprBy:
reviewdate: 2013-11-20
revBy:
prepdateA: 2013-11-12
prepbyA:
drawingNum:
scale:
codeIDNo: 52838
size:
nsn: MULTIPLE
itemdesc: ENERGY QAP E1.11
btnDSCC:
btnDSCP:
btnDSCR:
line1: DEFENSE ENERGY SUPPORT CENTER
line2: 8725 JOHN J. KINGMAN RD
line3: FORT BELVOIR, VIRGINIA 22060-6222
revcomments2:
totInstances: 0.00000000

File details come from the government source that posted it. Updated .