(X-Band) FAR-3220 Installation Manual.pdf

PDF 18 MB Posted

Attached to
Dockside Repairs to NOAA Ship HENRY B. BIGELOW
Solicitation number
EA-133M-18-00003
Issued by

About this file

Not Listed

View the file

Other files

File Type Posted
A0003_EA-133M-18-RP-00003.pdf PDF
HB-512_FV04_Fan_List_-_Cleaning.pdf PDF
RFP_EA-133M-18-00003.Rev.1.pdf PDF
HB_FY18_Dockside_Repair_Spec_(09-19-17).pdf PDF
A0002_EA-133M-18-RP-00003.pdf PDF
Freeman_Marine_Drawing_P0007776-001_Rev00_-_Sliding_Door.pdf PDF
A0001_EA-133M-18-RP-00003.pdf PDF
HB-170_FH22_Mast,_Rigging_&_Flagstaff_Layout_&_Details.pdf PDF
Compressed Air Hose Assy.pdf PDF
HB-170 FH22 Mast, Rigging _ Flagstaff Layout _ Details.pdf PDF
STANDARD_SPECS.zip ZIP file
HB-512 FV02 HVAC Diagram.pdf PDF
HB-512-4030 Assy Unit 4030 HVAC A_D.pdf PDF
Steering System Hose Assy.pdf PDF
Black-Grey Water Hose Assy.pdf PDF
MOC-510-1B HVAC Cleaning.pdf PDF
Oily Waste Hose Assy.pdf PDF
MOC-300-3 General Requirements for Electrical-Electronic Items.pdf PDF
Chilled Water Hose Assy.pdf PDF
16 CFR 1630 Standard for the Surface Flammability of Carpets and Rugs —
Furuno FAR 3000 Brochure.pdf PDF
HB-512-2010 Assy Unit 2010 HVAC A_D.pdf PDF
FSV DWG 451-00 Radar Diagrams with detailed wiring —
HB-512-2020 Assy Unit 2020 HVAC A_D.pdf PDF
HB-634 FZ04 Deck Covering Key Plan _ Sched.pdf PDF
HB-512-1020 Assy Unit 1020 HVAC A_D.pdf PDF
Auxiliary SW Cooling Hose Assy.pdf PDF
AMC-000-1F General Requirements for Contract Repair Work on NOAA Ships.pdf PDF
Bigelow Flex Hoses.xlsx XLSX spreadsheet
TECH_MANUALS.zip ZIP file
Navy MIL-D-3134J Deck Covering Materials.pdf PDF
Potable Water Hose Assy.pdf PDF
(S-Band) FAR-3230 Installation Manual.pdf PDF
HB-512-5010 Assy Unit 5010 HVAC A_D.pdf PDF
HB-110 FH04 Hull Sternbody Scantlings FR. 49 - FR. 82.pdf PDF
HB-631 FF04 Paint Schedule.pdf PDF
RFP_EA-133M-18-00003_BIGELOW_DOCKSIDE.pdf PDF
(093)Rescue Boat Handling System_rev 1.pdf PDF
J.2__USDL_Poster.pdf PDF
(128) Steering Gear.pdf PDF
HB-438 FE81 IBS System Block Wiring Diagram.pdf PDF
MOC-631-2D Coating Systems for Steel Surfaces.pdf PDF
HB-512-5050 Assy Unit 5050 HVAC A_D.pdf PDF
Sea Water Washdown Hose Assy.pdf PDF
EA-133M-18-RP-00003_DRAWINGS.zip ZIP file
HB-512-4020 Assy Unit 4020 HVAC A_D.pdf PDF
(091)refrigerationsys-scientificfreezer.pdf PDF
HB-085 FA02 General Arrangements.pdf PDF
J.4__Past_Performance_Questionnaire.pdf PDF
HB-512-1010 Assy Unit 1010 HVAC A_D.pdf PDF
Show 40 more

Latest 50 of 55 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Installation Manual

CHART RADAR

Model FAR-3230S-SSD(-BB)/FAR-3330S-SSD (Product name: MARINE RADAR)

SAFETY INSTRUCTIONS ................................................................................................ i SYSTEM CONFIGURATION .......................................................................................... iii EQUIPMENT LISTS........................................................................................................ vi

1. INSTALLATION.......................................................................................................1-1

1.1 Antenna Unit ......................................................................................................................1-1

1.2 Monitor Unit........................................................................................................................1-8

1.3 Radar Control Unit, Trackball Control Unit.........................................................................1-8

1.4 Power Supply Unit (PSU-016/PSU-018)..........................................................................1-11

1.5 Processor Unit .................................................................................................................1-12

1.6 Sensor Adapter MC-3000S/3010A/3020D/3030D (option) ..............................................1-13

1.7 Intelligent Hub HUB-3000 (option) ...................................................................................1-14

1.8 Switching Hub HUB-100 (option) .....................................................................................1-16

2. WIRING....................................................................................................................2-1

2.1 Overview............................................................................................................................2-1

2.2 Antenna Unit ......................................................................................................................2-3

2.3 Processor Unit .................................................................................................................2-10

2.4 Power Supply Unit ...........................................................................................................2-21

2.5 Monitor Unit......................................................................................................................2-25

2.6 Sensor Adapters (option) .................................................................................................2-26

2.7 LAN Signal Converter Kit (option)....................................................................................2-43

2.8 Intelligent Hub HUB-3000 (option) ...................................................................................2-47

2.9 How to Extend the Control Unit Cable (option) ................................................................2-48

3. SETTINGS AND ADJUSTMENTS ..........................................................................3-1

3.1 How to Access the Radar Installation Menu ......................................................................3-1

3.2 How to Align the Heading ..................................................................................................3-1

3.3 How to Adjust the Sweep Timing .......................................................................................3-2

3.4 How to Suppress Main Bang .............................................................................................3-3

3.5 Dual Radar Display ............................................................................................................3-3

3.6 Other Settings ....................................................................................................................3-6

4. INPUT/OUTPUT DATA............................................................................................4-1

4.1 Processor Unit ...................................................................................................................4-1

4.2 IEC 61162 Sentences ........................................................................................................4-2

APPENDIX 1 JIS CABLE GUIDE .............................................................................AP-1 APPENDIX 2 ROD TERMINALS ..............................................................................AP-2 APPENDIX 3 DIGITAL INTERFACE ........................................................................AP-7

PACKING LISTS ......................................................................................................... A-1 OUTLINE DRAWINGS ................................................................................................ D-1 INTERCONNECTION DIAGRAM ................................................................................ S-1 www.furuno.com All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

The paper used in this manual is elemental chlorine free.

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN

A : APR 2014.Printed in JapanAll rights reserved.

C1 : FEB . 16, 2015

Pub. No. IME-36190-C1

(AKMU ) FAR-3230S-SSD

0 0 0 1 7 8 0 3 5 1 2

SAFETY INSTRUCTIONS

The operator and installer must read the applicable safety instructions before attempting to install or operate the equipment.

DANGER Indicates a potentially hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION Indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury.

Warning, Caution Prohibitive Action Mandatory Action

DANGER

Wear a safety belt and hard hat when working on the antenna unit.

Serious injury or death can result if someone falls from the radar antenna mast.

WARNING

Radio Frequency Radiation Hazard

The radar antenna emits electromagnetic radio frequency (RF) energy which can be harmful, particularly to your eyes. Never look directly into the antenna aperture from a close distance while the radar ius in operation or eexpose yourself to the transmitting antenna at a close distance. Distances at which RF radiation level of 100, 50 and 10 W/m2 are given in the table below.

Note: If the antenna unit is installed at a close distance in front of the wheel house, your administration may require halt of transmission within a certain sector of antenna revolution. This is possible. Ask your FURUNO representive or dealer to provide this feature.

FAR-3230S-SSD(-BB)

FAR-3330S-SSD

RTR-111 (S-250W) SN36CF (12 ft)

WARNING

TransceiverModel Antenna 100 W/m2

N/A

50 W/m2 10 W/m2

N/A 1.0 m i

SAFETY INSTRUCTIONS

CAUTION

Observe the following compass safe distances to prevent deviation of a magnetic compass:

Note: For more information, please refer to IMO SN/Circ.271 “Guidelines for the installation of shipborne radar equip-ment.”

Standard compass

Antenna Unit

Processor Unit

Monitor Unit

Power Supply Unit

ECDIS Control Unit Radar Control Unit Trackball Control Unit

Switching Hub

Intelligent HUB

Sensor Adapter

Steering compassType

EC-3000

MU-190

MU-231

PSU-016

RCU-024

RCU-025

RCU-026

(HUB-100)

HUB-3000

MD-3000S

MD-3010A

MD-3020D

MD-3030D

1.90 m 1.20 m

2.40 m

1.65 m

0.85 m

1.90 m

0.30 m

0.30 m

0.30 m

1.00 m

1.20 m

2.05 m

0.75 m

1.05 m

0.90 m

1.55 m

1.05 m

0.55 m

1.20 m

0.30 m

0.30 m

0.30 m

0.60 m

0.75 m

1.35 m

0.50 m

0.70 m

0.60 m

RSB-133

PSU-018 1.80 m 1.15 m

Do not open the equipment unless totally familiar with electrical circuits and service manual.

Only qualified personnel are allowed to work inside the equipment.

WARNING

ELECTRICAL

SHOCK

HAZARD

Construct a suitable service platform from which to install the antenna unit.

Serious injury or death can result if someone falls from the radar antenna mast.

Turn off the power at the mains switchboard before beginning the installation.

Fire, electrical shock or serious injury can result if the power is left on or is applied while the equipment is being installed.

Be sure that the power supply is compatible with the voltage rating of the equipment.

Connection of an incorrect power supply can cause fire or damage the equipment.

Use only the specified power cable.

Fire or damage to the equipment can result if a different cable is used.

Do not install the monitor unit, processor unit, power supply unit (PSU), or control unit in a dusty environment, or one where the units may get wet from rain or water splash.

Dust or water in the units can result in fire, electrical shock, or damage to the equipment.

Attach protective earth securely to the ship's body.

The protective earth (grounding) is required for the AC power supply to prevent electrical shock.

ii

SYSTEM CONFIGURATION

Basic configuration is shown with solid line.

*: See the notes on page iv.

NOTICE

The radar(s) must be interconnected to the following type approved sensors:

� Gyrocompass meeting the requirements of the IMO resolution A.424(XI).

� EPFS meeting the requirements of the IMO resolution MSC.112(73).

� SDME meeting the requirements of IMO resolution MSC.96(72).

The radar may be interconnected via HUB-3000 to other FURUNO processing units having approved LAN ports.

100-115/220-230 VAC

1ø, 50-60 Hz

PSU-016 or PSU-018

POWER SUPPLY

UNIT

EC-3000

PROCESSOR

UNIT

Serial 1, 2

IEC 61162-2

(Gyrocompass1, AIS)

Serial 3 - 7

IEC 61162-1

(EPFS2 (Navigator), SDME (Speed Log), Echo Sounder, Wind, Alarm5, Navtex, etc.)

Digital Out 1 - 65

1: System Fail 2: Power Fail 3: Normal Close 1 4: Normal Close 2 5: Normal Open 1 6: Normal Open 2

100-230 VAC

1ø, 50-60 Hz

Transformer

RU-1803

440 VAC

1ø, 50-60 Hz

Sensor Adapter4 or Switching HUB

HUB-100

Radar Control Unit RCU-025 Trackball Control Unit RCU-026

ECDIS Control Unit RCU-024 Radar Control Unit RCU-025

Trackball Control Unit RCU-026

Monitor Unit MU-1903 MU-2313

Digital In (ACK IN)

VDR

Intelligent Hub HUB-3000

ANTENNA UNIT

(w/Performance Monitor PM-52B)

SN36CF-RSB-133TRANSCEIVER UNIT

RTR-111

Sub monitor Antenna Cable

LAN Serial

Select one

Select one

ECDIS Control Unit RCU-024 Radar Control Unit RCU-025

Trackball Control Unit RCU-026

Select one

100-115/220-230 VAC

1ø, 50-60 Hz

(for de-icer) iii

Category of units

Antenna units: Exposed to the weather Other units: Protected from the weather

Notes

1. The gyrocompass must be type approved for compliance with IMO resolution A.424(XI) (and/ or resolution A.821(19) for installation on HSC). The gyrocompass must also have an update rate that is adequate for the ship’s rate of turn. The update rate must be better than 40 Hz (HSC) or 20 Hz (conventional vessel).

2. The EPFS must be type approved for compliance with IMO resolution MSC.96(72).

3. These monitors have been approved by the IMO, MU-190 for CAT 2C and CAT 2HC, MU-231 for CAT 1C and CAT 1HC. If a different monitor is to be used on IMO vessels, its effective diameter must meet the applicable Category requirements:

• CAT 1C and CAT 1HC: effective diameter 320 mm or higher

• CAT 2C and CAT 2HC: effective diameter 250 mm or higher

For installation, operation and viewing distance of other monitor, see its manuals.

For BB type, a monitor unit is prepared by user.

4. The sensor adapters are Control Serial MC-3000S, Analog IN MC-3010A, Digital IN MC- 3020D and Digital OUT MC-3030D.

5. Characteristics of contact output for Alarm:

• (Load current) 250 mA

• (Polarity) Normally Open: 2 ports, Normally Close: 2 ports

• Serial I/O for alarm is also possible, which complies with IEC 61162-1.

iv

Interswitch connection

When multiple radars are used, connect, to the EC-3000, the HUB-3000 to the LAN1 port, and HUB-100 to the LAN2 port. This configuration lets each radar as a standalone radar in case of HUB malfunction.

Radar Component Combinations

RADAR

MODEL

ANTENNA

UNIT

TRANSCEIVER

UNIT

POWER SUPPLY

UNIT

FAR-3x10 FAR-3x20

XN12CF-RSB-128

XN20CF-RSB-128

XN24CF-RSB-128

RTR-105

PSU-014

RTR-106

FAR-3x20W

XN20CF-RSB-130

XN24CF-RSB-130

RTR-108

FAR-3x30S SN36CF-RSB-129 RTR-107 PSU-014 PSU-015FAR-3x30SW SN36CF-RSB-131 RTR-109

FAR-3x30S-SSD SN36CF-RSB-133 RTR-111

PSU-016

PSU-018

EC-3000

PROCESSOR

UNIT

Radar Control Unit RCU-025 Trackball Control Unit RCU-026

ECDIS Control Unit RCU-024 Radar Control Unit RCU-025

Trackball Control Unit RCU-026 (Max. 2)

Select one

Select one

Serial 1,2 (IEC 61162-2)

Serial 3-7 (IEC 61162-1)

VDR

Switching

HUB

HUB-100

Sensor Adapter

MC-3000S

Serial interface

Intelligent HUB

HUB-3000

POWER SUPPLY UNIT

ANTENNA UNIT

TRANSCEIVER UNIT

LAN3

LAN1

LAN2

100-230 VAC

1ø, 50-60 Hz

100-115/220-230 VAC

1ø, 50-60 Hz (For de-icer)

Sub Monitor

Gateway network equipment

(Radar, ECDIS, etc.)

Serial8

LAN2

- Digital Out×6 (Power fail/system fail/NO×2.NC×2)

- Digital in (ACK in)

Monitor Unit MU-190 MU-231 (or equivalent for -BB model)

Radar Control Unit RCU-025 Trackball Control Unit RCU-026

ECDIS Control Unit RCU-024 Radar Control Unit RCU-025 Trackball Control Unit RCU-026 (Max. 2)

Select one

Select one

Serial 1,2 (IEC 61162-2)

Serial 3-7 (IEC 61162-1)

VDR

- Digital Out×6 (Power fail/system fail/NO×2.NC×2)

- Digital in (ACK in)

EC-3000

PROCESSOR

UNIT

LAN3 Serial8

LAN1

100-230 VAC

1ø, 50-60 Hz

Sub Monitor

100-115/220-230 VAC

1ø, 50-60 Hz 100-115/220-230 VAC

1ø, 50-60 Hz

Sensor Adapter

MC-3010A

Sensor Adapter

MC-3020D

Sensor Adapter

MC-3030D

Analog interface

Digital in interface

Digital out interface

POWER SUPPLY UNIT

ANTENNA UNIT

TRANSCEIVER UNIT

100-115/220-230 VAC

1ø, 50-60 Hz (For de-icer)

Monitor Unit MU-190 MU-231 (or equivalent for -BB model) v

EQUIPMENT LISTS

Standard Supply

Console Type

Name Type Code No. Qty Remarks Antenna Unit SN36CF-RSB129-107 - 1 Control Unit RCU-025 - Select one Standard type

RCU-026 - Trackball type Power Supply Unit

PSU-014 - Select one

For 24rpm PSU-015 - For 42rpm

Processor Unit EC-3000 - 1 Monitor Unit MU-190 - Select one For FAR-3230S

MU-231 - For FAR-3330S Installation Materials

CP03-35202 001-249-880 1 For antenna CP03-35402 001-255-430 1 For RSB CP03-35404 001-270-080 1 For RSB (w/de-icer)

CP03-35500 000-024-096

Select one

15 m cable CP03-35510 000-024-097 30 m cable CP03-35520 000-024-098 40 m cable CP03-35530 000-024-099 50 m cable CP03-35301 001-249-770 1 For PSU-014/015 CP24-02120 000-024-925 1 For EC-3000 CP24-02200 000-022-508 1 For RCU-025 CP24-02300 000-022-509 1 For RCU-026

Accessories FP24-00603 001-285-760 1 For EC-3000 FP24-00701 001-170-820 1 For RCU-025 FP24-00801 001-170-920 1 For RCU-026

Spare Parts SP24-00601 001-170-660 1 For EC-3000, Fuse: FGMB

125V 10A PBF (000-157-

470-10, 3 pcs.)

SP24-00602 001-170-670 1 For EC-3000, Fuse: FGMB

250V 5A PBF (000-157-570-

10, 3 pcs.)

SP03-17641 001-249-740 1 For PSU-014, Fuse: FGBO

250V 7A PBF (000-178-084-

10, 2 pcs.)

SP03-17651 001-249-750 1 For PSU-015, Fuse: FGBO

250V 7A PBF (000-178-084-

10, 2 pcs.), FGBO 250V 3A

PBF (000-155-841-10, 2

pcs.)

Hoist S-band Antenna Manual

C32-01303-* - 1

Name Type Code No. Qty Remarks

Display Unit RCN-303 - 1 w/FAR-3230S RCN-304 - 1 w/FAR-3330S vi

Optional Supply

Name Type Code No. Remarks LAN Signal Converter

OP03-223-2 -

Cable Extension Kit

OP03-224-2 001-254-400

De-icer Kit OP03-227 001-254-330 Rectifier Unit RU-3424 - For 220 VAC

RU-1746B-2 -

Transformer Unit RU-1803 - Converts 440 VAC to 100 VAC, for pro-cessor unit

RU-3305-0 - Converts 110/115/220/230 VAC to 100 VAC, for deicer

RU-5693 - Converts 110 VAC to 220 VAC, for transceiver unit

RU-6522 - Converts 220 VAC to 200 VAC, for transceiver unit

RU-5466-1 - Converts 440 VAC to 220 VAC, for transceiver unit

Control Unit RCU-024 - ECDIS standard type RCU-026 - Trackball type

LAN Cable Assy.

MOD-Z072-050+ 001-167-890-10

Sensor Adapter

MC-3000S - Serial type MC-3010A - Analog IN MC-3020D - Digital IN MC-3030D - Digital OUT

Intelligent HUB HUB-3000 - Switching HUB HUB-100 - See manual of HUB-100.

AC/DC

Power Supply Unit

PR-240 -

Installation Materials

CP03-28900(10M) 000-082-658 FR-FTPC-CY 10 m, for sensor adaptor CP03-28910(20M) 000-082-659 FR-FTPC-CY 20 m, for sensor adaptor CP03-28920(30M) 000-082-660 FR-FTPC-CY 30 m, for sensor adaptor CP24-02900(10M) 001-208-050 LAN cable 10 m, for HUB-3000 CP24-02910(20M) 001-208-060 LAN cable 20 m, for HUB-3000 CP24-02920(30M) 001-208-040 LAN cable 30 m, for HUB-3000

Connector CP03-28901 008-542-460 Bracket Assembly

OP26-5 000-016-270 For MU-190 OP26-15 001-116-730 For MU-231

Flush Mount Kit

OP26-12 001-116-280 For MU-190 OP26-17 001-116-750 For MU-231

Hood Assem-bly

OP26-6 001-080-930 For MU-190 OP26-16 001-116-740 For MU-231 vii

Cable Assy DVI-D/D

S-LINK 5M

001-132-960-10 Between processor and control units, 5 m

DVI-D/D

S-LINK 10 M

001-133-980-10 Between processor and control units, 10 m

6TPSH-XH12X2-

L5.0SP1

001-186-260-10 For RCU-024/025, 5 m

6TPSH-XH12X2-

L10SP1

001-186-270-10 For RCU-024/025, 10 m

6TPSH-XH12X2-

L20SP1

001-186-280-10 For RCU-024/025, 20 m

6TPSH-XH12X2-

L30SP1

001-186-290-10 For RCU-024/025, 30 m

6TPSH-XH12X2-

L5.0SP2

001-186-310-10 For RCU-026, 5 m

6TPSH-XH12X2-

L10SP2

001-186-320-10 For RCU-026, 10 m

6TPSH-XH12X2-

L20SP2

001-186-330-10 For RCU-026, 20 m

6TPSH-XH12X2-

L30SP2

001-186-340-10 For RCU-026, 30 m

DSUB9P-X2-L5M 001-188-260 For MU-190/231 brill control, 5 m DSUB9P-X2-L10M 001-188-270 For MU-190/231 brill control, 10 m OP24-32 001-188-300 USB cable, between processor unit and control unit DVI-BNCX5-L2000 001-204-150 For VDR connection

DSUB9P-X2-L5M-

WP

001-207-890 For monitor unit, 5 m, waterproofing type

DSUB9P-X2-L10M-

WP

001-207-900 For monitor unit, 10 m, waterproofing type

DSUB9P-X2-A-L5M 001-252-580 For Hatteland display DSUB9P-X2-A-L10M 001-252-590 For Hatteland display

Monitor Unit MU-190 - For FAR-3230S(-BB) MU-231 - For FAR-3330S

Terminal Opener

OP24-33 001-188-850

Cable MC1.5-W-L600 001-187-470-10 For sensor adapters, 0.6 m MC1.5-W-L1000 001-187-480-10 For sensor adapters, 1 m MC1.5-W-L2000 001-187-490-10 For sensor adapters, 2 m MC1.5-W-L3000 001-187-500-10 For sensor adapters, 3 m

Crimping Tool CRIMPFOX10S 001-206-920 For ferrule for sensor adaptor Spare Parts SP24-00801 (BOX) 001-235-320 For HUB-3000 Program Instal-lation Software

OP03-230 001-285-780 DVD-R

Operator’s Manual

OME-36160-* -

OMJ-36160-* -

Magnetron Re-place Instruc-tion Manual

E32-01306-* - J32-01306-* -

Name Type Code No. Remarks viii

About the category sticker

This radar meets the requirements in IEC62388 (Marine naviga-tion and radio communication equipment and systems-Ship born radar-Performance requirements, method of testing and required test results.) Check the appropriate box on the sticker which is pre-attached on the processor unit, according to your radar’s specification. Refer to the table shown below to confirm your cat-egory.

Category Radar type ANT, rotation speed CAT 1C FAR-3330S 24 rpm CAT 1HC Same model as above 42 rpm CAT 2C FAR-3230S, FAR-3230S-BB 24 rpm CAT 2HC Same models as above 42 rpm

Comply with MSC.192(79)

CAT 1C

CAT 2C

CAT 1HC

CAT 2HC

Sticker for category ix

This page is intentionally left blank.

x

1. INSTALLATION

1.1 Antenna Unit

1.1.1 Installation considerations

• The antenna unit is generally installed either on top of the wheelhouse or on the ra-dar mast, on a suitable platform. Locate the antenna unit in an elevated position to permit maximum target visibility.

• A line of sight from the antenna unit to the bow of the ship must hit the surface of the sea in not more than 500 m or twice the ship’s length, depending whichever val-ue is smaller, for all load and trim conditions.

• Install the antenna unit so that any blind sectors caused by objects (mast, etc.) are kept to a minimum. A blind sector must not exist in arc of the horizon from right ahead to 22.5° aft of the beam to either side (see the figure below). Also, individual blind sectors of more than 5°, or the total arc of both blind sectors of more than 20°, must not occur in the remaining arc (Figure 2). Note that any two blind sectors sep-arated by 3° or less are regarded as one sector.

NOTICE

Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment.

Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors.

less than 500 m or twice the ship's length

Figure 1 Figure 2 less than 3°

22.5°22.5°

270° 90° a, b, c: less than 5° respectively a+b+c+... : less than 20° a, b, c: less than 5° respectively a+b+c+... : less than 20° 1-1

• Do not install the antenna where extreme winds may strike the port and starboard sides of the antenna.

• Install the antenna unit away from interfering high-power energy sources and TX ra-dio antennas.

• Keep the lower edge of the antenna unit above the safety rail by at least 500 mm.

• Install two antenna units as shown in the right figure.

• No funnel, mast or derrick shall be within the vertical beamwidth of the antenna unit in the bow direction, especially zero degree ±5°, to prevent blind sectors and false echoes on the radar picture.

• It is rarely possible to place the antenna unit where completely clear view in all di-rections is available. Therefore, you should determine the angular width and relative bearing of any shadow sectors for their influence on the radar at the first opportunity after fitting.

• Locate the antenna of EPFS clear of the radar antenna to prevent interference to the EPFS. A separation of more than two meters is recommended.

• A magnetic compass will be affected if the antenna unit is placed too close to the magnetic compass. Observe the compass safe distances on page ii to prevent in-terference to a magnetic compass.

• Do not paint the radiator aperture, to ensure proper emission of the radar waves.

• Ground the unit with the ground wire (supplied).

• Deposits and fumes from a funnel or other exhaust vent can affect the aerial perfor-mance and hot gases may distort the radiator portion. Do not install the antenna unit where the temperature is more than 55°C.

• Leave sufficient space around the unit for maintenance and servicing. See the an-tenna unit outline drawing for recommended maintenance space.

Note: For more information, please refer to IMO SN/Circ.271 “Guidelines for the in-stallation of shipborne radar equipment”.

more than 20° more than 1 m 1-2

1.1.2 Installation precaution for S-band antenna unit

If an S-band antenna unit is mounted near the end of a platform to provide sufficient rotation clearance for the radiator, the antenna unit, because of its weight, swings up and down by ship’s vibration and rolling. This exerts excessive levels of stress at the base of the radiator, which can damage the radiator. To prevent this, relocate the an-tenna unit, or if relocation is not possible, reinforce the platform.

1.1.3 How to assemble the antenna unit

The antenna unit consists of the antenna radiator (w/antenna support) and the anten-na unit chassis, and they are packed separately. Fasten the antenna radiator to the antenna unit chassis as follows:

1. Remove the protective waveguide cap from the waveguide on the ra-diator bracket.

2. Put the radiator on the radiator bracket so the guide pins of the antenna support fits into the guide pin holes on the radiator bracket. (Orient the logo of the radiator to the side with bow mark on the bracket. If reversely oriented the radiator cannot be set to the bracket.)

3. Coat the threads of eight hex bolts (M12×50, supplied) with marine sealant sup-plied.

Mast for DF, etc.

Mount the antenna unit directly on the mast or on the platform, as near as possible to center of the mast.

Remarkable vibration (pitching)Mounting position

EXAMPLE

Mast for DF, etc.

Waveguide cap

Radiator bracket

Antenna shassis

Antenna unit chassis

Antenna support

Antenna radiator

Front

BowBow

Bow markBow mark

Guide pin holesGuide pin holes 1-3

4. Set the antenna radiator to the radiator bracket from the bottom of the bracket with the eight hex bolts, spring washers and flat washers. The torque must be 49 N•m.

5. Coat the screws fixed at step 4 with ma-rine sealant (supplied) as shown in the right figure.

6. Connect the coaxial cable from the an-tenna unit to the rotary joint. The torque must be 25 N•m.

Note 1: The connector of the coaxial cable must be connected vertically.

Note 2: The coaxial cable must be hor-izontal and must not contact the hole of the antenna support.

Note 3: If the coaxial cable is long, bend the cable some distance from the con-nector. Insert surplus cable into antenna support. Connect the cable to the rotary joint straightly.

7. Coat the hex bolts (M12×40, 4 pcs.) for the support cover with marine sealant (supplied).

8. Fasten the support cover with the bolts, spring washers and flat washers. The torque must be 20 N•m.

Note 1: Make sure the safety rope does not contact the antenna support cover.

Note 2: Set the screw for the safety rope to come to the left when viewed from the front side of the antenna.

Bottom view of the bracket (eight places)(eight places)

Hex bolt (with marine sealant)

Flat washer

Spring washer

Coat with marine sealant.

Connect vertically.Connect vertically.

Hole of Antenna support Hole of Antenna support

Connect the cable straightly.Connect the cable straightly.

Screw (four places) Screw (four places)

Antenna support coverAntenna support cover

Safety ropeSafety rope

Front view

Left when viewed from the front side 1-4

1.1.4 How to hoist the antenna unit

The antenna unit may be assembled before hoisting it to the mounting platform. Attach lifting belt slings to the chassis, NOT the antenna radiator, as shown in the figure be-low.

There are two methods to hoist the antenna unit.

Method 1

Method 2

Fasten belt sling to a shackle, pass belt sling around antenna support and fasten other end of belt sling to other shackle.

Set belt slings to antenna support.

Belt sling

Bow side up

Pass belt sling around antenna support.

Antenna supportAntenna support

Shackle (left, right)

Shackle (left, right)

Lifting fixture (ø20)Lifting fixture (ø20)

Belt slingBelt sling 1-5

1.1.5 How to fasten the antenna unit to the mounting platform

1. Construct a suitable mounting platform referring to the outline drawing at the end of this manual.

• The diameter of the mast for fixing the antenna unit platform must be over 250 mm.

• The thickness of the antenna unit platform must be over 15 mm.

• The reinforcement rib must be installed diagonally as shown below.

2. Referring to the outline drawing, drill eight mounting holes in the mounting plat-form.

3. Put the antenna unit on the mounting platform, then orient the unit so the bow mark on its base is facing the ship’s bow.

4. Fasten the antenna unit to the mounting platform with M12×70 hex bolts, nuts, flat washers, spring washers and seal washers (supplied). The torque must be 49 N•m.

Note: The bolts can also be inserted from the underside of the platform.

Over 15 mm

250 mm diameter or more, 6 mm thick or more

Use two nuts.

Ship's bow

Install the reinforcement rib diagonally.

Bottom view

Seal washer

Corrosion proof rubber mat

Use two nuts.

(Torque 49 N•m)

Flat washer

Spring washerM12×70 (eight places) 1-6

5. Using a hex bolt (M6×x25), nut (M6), spring washer (M6) and flat washer (M6), establish the ground system on the mounting platform as shown below. The loca-tion must be within 340 mm of the ground terminal on the antenna unit. Connect the ground wire (RW-4747, 340 mm, supplied) between the grounding point and ground terminal on the antenna unit. Coat the hardware of the ground system with the marine sealant (supplied).

Antenna chassis side

Mounting platform side

Ground wire Antenna chassisAntenna chassis

Fasten ground wire then coat with marine sealant.

Marine sealant Marine sealant

Hex bolt

OR

Ground wire Hex nut

Arrange ground terminal as close as possible to antenna unit.

Hex bolt

Flat washer

Hex nut Spring washer

Flat washer Spring washer

Ground wire

Coat with marine sealant.

Flat washer Mounting PlatformMounting Platform

Welding

Mounting PlatformMounting Platform 1-7

1.2 Monitor Unit

See the operator’s manual for MU-190 (OMC-44670) or MU-231 (OMC-44690). Keep in mind the following points when selecting a location.

Installation considerations

• Locate the monitor unit not to block the view from the bridge window because of the frame of the window.

• Locate the monitor unit under the condition which the ambient illumination is easy to observe.

1.3 Radar Control Unit, Trackball Control Unit

The control units can be installed on a desktop or flush mounted in a console. For the desktop installation the unit can laid flat or tilted.

Note: The control unit RCU-025 can be used instead of the RCU-020 (for FAR-2xx7) mounted in the connection stand (OP03-184 or OP26-20) using the optional kit

OP24-31.

Installation considerations

Keep in mind the following points when selecting a location.

• Select a location where the control unit can be operated easily.

• Locate the unit away from heat sources because of heat that can build up inside the cabinet.

• Locate the equipment away from places subject to water splash and rain.

• Leave sufficient space at the sides and rear of the unit to facilitate maintenance.

• Determine the mounting location considering the length of the signal cable between the control unit and the processor unit.

• A magnetic compass will be affected if the control unit is placed too close to the magnetic compass. Observe the compass safe distances in the SAFETY IN- STRUCTIONS prevent interference to the compass.

• Be sure to connect the ground wire (between the earth terminal on the chassis and the ship’s earth).

Bridge window

Viewing pointViewing point Viewing pointViewing point

Bridge window 1-8

• Fasten the USB cable with the cable tie.

1.3.1 Desktop installation

How to mount the unit tilted

Use the desk fixing plate to mount the unit tilted.

1. Fix the desk fixing plate to the bottom of the control unit.

2. Fix the control unit with self-tapping screws (φ5×20, local supply).

How to mount the unit flush with mounting surface

Do this installation to install the control unit flat on the mounting surface.

1. Drill four mounting holes of 5 mm (4 mm, for RCU-026) diameter referring to the outline drawing at the back of this manual.

2. Fix the control unit with four screws, M4, local supply (M3, for RCU-026), from the underside of the desktop.

Ex. Radar control unit, bottom view RCU-025

USB cableUSB cable

Cable tieCable tie

Cable routing pegCable routing peg

Desk fixing plate

RCU-026RCU-025

RCU-026RCU-025

1-9

1.3.2 Installation in a console

Use the optional flush mount kit (OP24-24 for RCU-024/025, OP24-27 for RCU-026) to install the control unit in a console.

Note: For flush mounting in a panel, the mounting surface must be flat. Do not install the unit on an uneven surface.

1. Prepare a cutout in the location as shown in the figure as below.

2. Set the control unit to the cutout.

3. Attach the mounting plate to the control unit with four screws from the rear side.

4. Insert the wing nut (or hex. nut) to each wing screw then fix the wing screw to each mounting plate.

5. Fasten each wing screw and then fasten the wing nuts (or hex. nuts) as shown in figure below.

388±2 110±2

170±2170±2

For RCU-024/025 For RCU-026

RCU-024/025 RCU-026

1-10

1.4 Power Supply Unit (PSU-016/PSU-018)

1.4.1 Installation considerations

The Power Supply Unit can be mounted on a bulkhead or deck. Keep in mind the fol-lowing points when selecting a location.

• Locate the unit away from heat sources because of heat that can build up inside the cabinet.

• Select a location where the vibration is minimal.

• Locate the equipment away from places subject to water splash and rain.

• Make the service clearance of 100 mm in front of the vent hole (front and rear sides).

• Leave sufficient space at the sides and rear of the unit to facilitate maintenance.

• Connect the ground wire between the earth terminal on the chassis and the ship’s earth.

• A magnetic compass will be affected if the unit is placed too close to the magnetic compass. Observe the compass safe distances on page ii to prevent disturbance to the compass.

1.4.2 How to mount the power supply unit

Use four bolts (M6, local supply) to fix the power supply unit.

Note: For bulkhead mounting, the notches on the unit must face the deck.

Front Rear

(PSU-016)

(PSU-018)

: vent hole

(ex: PSU-016)

: Bolt holes

NotchNotch 1-11

1.5 Processor Unit

1.5.1 Installation considerations

Keep in mind the following points when selecting a location.

• Locate the processor unit away from heat sources because of heat that can build up inside the cabinet.

• Select a location where the vibration is minimal.

• Locate the equipment away from places subject to water splash and rain.

• Make the service clearance of 100 mm in front of the vent hole (left side).

• Leave sufficient space at the sides and rear of the unit to facilitate maintenance.

• Be sure to connect the ground wire (between the earth terminal on the chassis and the ship’s earth).

• A magnetic compass will be affected if the processor unit is placed too close to the magnetic compass. Observe the compass safe distances in the "SAFETY IN- STRUCTIONS" to prevent interference to a magnetic compass.

• Leave the dummy plate fastened, to prevent the wrong operation of the power switch. The items behind the plate are for use by the serviceman.

• Install the processor unit on the floor, or on a bulkhead with the following direction (horizontal), because of the DVD drive unit.

Processor unit, front view

Keep the dummy plate in this position.

Keep the dummy plate in this position.

OK

UP

1-12

1.5.2 How to install the processor unit

Use four bolts (M6, local supply) to fix the processor unit.

1. Use 10 binding head screws (M4×8, supplied) to attach the chassis bases 1 and 2 to the processor unit.

Note: For bulkhead mounting, attach the chassis base 2 so that the notches on it are facing the deck.

2. Use six bolts (M6, local supply) to fix the processor unit.

1.6 Sensor Adapter MC-3000S/3010A/3020D/3030D

(option)

Installation considerations

When you select a mounting location, keep in mind the following points:

• Locate the adapter away from heat sources because of heat that can build up inside the cabinet.

• The vibration must be minimal.

• Locate the equipment away from places subject to water splash and rain.

• Be sure to connect the ground wire (between the earth terminal on chassis and the ship’s earth).

• Leave sufficient space at the sides and rear of the unit to facilitate maintenance.

• A magnetic compass will be affected if the adapter is placed too close to the mag-netic compass. Observe the compass safe distances in the "SAFETY INSTRUC- TIONS" (on page i) to prevent interference to a magnetic compass.

• For MC-3000S, use a Cat5 cable of correspondence.

Chassis base 1

Chassis base 2Notch Notch

: Bolt holes

Notch 1-13

• Select the mounting location considering the number of the sensor adapters con-nected.

A maximum of eight MC-3000S can be connected to a sensor network (for the re-dundant connection:16).

A maximum of 10 sensor adapters (MC-3010A/3020D/3030D) can be connected to a MC-3000S. However, note that five MC-3010A can be connected.

• Select the location so that the length of the cables among the sensor adapters (MC- 3000S, 3010A, 3020D and 3030D) is less than 6 m. If the length is more than 6 m, the adapters may not work properly.

How to install the sensor adapter

1. Unfasten four binding screws to remove the cover from the sensor adapter.

2. Fasten four self-tapping screws (φ4×20, supplied) to fix the sensor adapter.

3. Reattach the cover.

1.7 Intelligent Hub HUB-3000 (option)

Use the optional Intelligent Hub HUB-3000 to connect gateway network equipment.

Do not connect this network to the shipborne LAN network. Further, do not connect a PC to this network, other than for maintenance.

Installation considerations

Keep in mind the following considerations when selecting a location.

• Locate the hub away from heat sources because of heat that can build up inside the cabinet.

• The vibration must be minimal.

• Locate the equipment away from places subject to water splash and rain.

• Be sure to connect a ground (between the earth terminal on chassis and the ship’s earth).

• Leave sufficient space at the sides and rear of the unit to facilitate maintenance.

MC-3000S MC-3010A/3020D/3030D

1-14

• A magnetic compass will be affected if the adapter is placed too close to the mag-netic compass. Observe the compass safe distances in the "SAFETY INSTRUC- TIONS" (on page i) to prevent interference to a magnetic compass.

How to install the HUB-3000

1. Use two binding screws (M3×6, supplied) to attach the cable clamp (supplied) to the bottom of the HUB-3000.

2. Fasten four self-tapping screws (φ4×20, supplied) to fix the unit.

HUB-3000, bottom view

Cable clamp

Binding screw (M3×6, 2 pcs)

: Screw holes 1-15

1.8 Switching Hub HUB-100 (option)

Use the optional Switching Hub HUB-100 to connect sensor networks. This network cannot be connected to the shipborne LAN network. Further do not connect a com-mercial PC to this network, other than for the maintenance.

For the installation procedures, see the operator’s manual for HUB-100 (Pub. No.

OMC-35191).

Installation considerations

Keep in mind the following points when selecting a location.

• Locate the hub away from heat sources because of heat that can build up inside the cabinet.

• The vibration must be minimal.

• Locate the equipment away from places subject to water splash and rain.

• Make sure that the ground wire is connected between the earth terminal on chassis and the ship’s earth.

• Leave sufficient space at the sides and rear of the unit to facilitate maintenance.

• A magnetic compass will be affected if the adapter is placed too close to the mag-netic compass. Observe the compass safe distances in the SAFETY INSTRUC- TIONS to prevent compass malfunction.

1-16

2. WIRING

2.1 Overview

Cabling considerations

To lessen the chance of picking up electrical interference, avoid where possible rout-ing the antenna cable (power and LAN) near other onboard electrical equipment (ra-dars, TX radio antennas, etc.). Also avoid running the cable in parallel with power ca-bles. When crossing with other cable, the angle must be 90° to minimize the magnetic field coupling.

The antenna cable between the antenna, PSU and processor units is available in lengths of 15 m, 30 m, 40 m, and 50 m. Whatever length is used, it must be unbroken;

namely, no splicing allowed. Use the antenna cable as short as possible to minimize attenuation of the signal.

The radar must be connected to an emergency power source, as required by SOLAS

II-1.

About network construction

About wiring

• Use the optional Switching Hub HUB-100 to connect the sensor networks. For the gateway networks, use the optional Intelligent Hub HUB-3000.

• Do not connect the ship’s LAN network to the optional HUBs. Also, commercial PCs cannot be connected to the gateway network, other than for maintenance.

• To connect the FEA-2xx7, FCR-2xx9, FMD-32x0 or FAR-2xx7 series via LAN net-work, use the INS net-work.

• Use the optional USB cable (type: OP24-32) to connect to the USB port on the control unit.

• The length of the USB cable should be within 5 m to prevent equipment trouble.

• The length of LAN cables must be within 50 m.

• Use the Cat5e or Cat6 LAN cable for the network if available locally.

• If LAN cables are not available locally, use the optional LAN cables (FR-FTPC-CY for sensor network, DTI-C5E350 VCV for gateway network).

• If extension or division of the DVI or RGB cables is necessary, use the dividers shown below.

• DVI cable divider: DVI-12A (maker: IMAGENICS)

• RGB divider: CIF-12H, DD-106 or WBD-14F (maker: IMAGENICS)

• Make sure that the ground wires are connected between the ground terminals on each equipment and the ship’s earth.

• If a UPS (user supply) is connected to this equipment, be sure that the grounding lamp does not light.

• The output from the UPS must be a sine wave, as in the right figure. 50Hz

60Hz 2-1

Standard wiring

A Cat 5e LAN cable (RW-00135) connects between the antenna unit and the power supply unit (PSU). The maximum length of the cables between the Processor Unit and the antenna unit is 80 m.

100-230 VAC

Antenna Unit

DPYC-2.5

: Cable requires fabrication

DSUB9P-DSUB9P

5 m/10 m

Processor Unit

EC-3000

100-230 VAC

DVI-D/D SINGLE LINK

5 m/10 m

MU-190

(for FAR-3230S-SSD(-BB))

MU-231

(for FAR-3330S-SSD)

PSU-016/018

Sensor Adapter or HUB-100

Serial: TTYCS-1Q

FR-FTPC-CY

100-230 VAC

GYRO, AISTTYCS-4

×2

GPS, LOG, E/S,

WIND, ALARM,

NAVTEX, etc.

TTYCS-1Q

×5

5 m (for USB)

30 m

×2

TTYCS-10

Monitor Unit

DPYC-1.5

VDR

RGB cable

IEC60320-C13-L5M

HUB-3000

5 m (for USB)

30 m

USB

memory

Radar Control Unit

RCU-025

Trackball Control Unit

RCU-026

USB

memory

LAN Power

RW-00135

15/30/40/50 m

100-115/220-230 VAC

Power Supply Unit

DTI-C5E 350 VCV

(10/20/30 m)

LAN: DTI-C5E 350 VCV (10/20/30 m) (or Cat 5e LAN cable (local supply))

I/O Board

LAN: MOD-Z072-050+

Sub monitor

RW-00136

15/30/40/50 m

De-icer

DPYCY-1.5

100-115/

220-230 VAC

ALARM

SYSTEM

2-2

2.2 Antenna Unit

Three cables are connected to the antenna unit: antenna cable, cable for the sub mon-itor (option) and power cable for the deicer (option). The procedure shows how to con-nect all cables. Disregard the descriptions for the optional equipment if not applicable.

2.2.1 How to fabricate the cables

Antenna cable RW-00135

See "How to fabricate the LAN cable" on page 2-12 for how to attach the LAN cable connector.

Antenna cable RW-9600/6895/4873 (for retrofit installation)

The optional LAN signal converter kit is required for retrofit installation. For wiring in case of a retrofit, see section 2.7.

For RW-9600: The white, red, and green wires are not used. Attach a single crimp-on lug (FV5.5-S4(LF), yellow) locally to the wires. (These wires will be connected togeth-er with the shield of the power line, in the next section.)

For RW-6895/4873: Fifteen wires are not used. Cut the wires and bind them with vinyl tape. Do not connect the wires to ground.

Rear side Antenna motor switch

Cable for sub monitor

Cable for antenna

Cable for deicer

ShieldShieldArmorArmor

LAN cable

500500 Power line

Remove the vinyl tape.

SheathSheath

SheathSheath

Vinyl tape

Armor Sheath

Crimp-on lug

ShieldShield470470SheathSheath

Vinyl tape

Coaxial cable

Coaxial cable

10 30

14 5 9

500500

400400 2-3

Cable RW-00136 (for a sub monitor)

Cable DPYCY-1.5 (for the optional deicer)

Wrap the supplied spiral tube around the power cable for de-icer, starting from the pc board.

2.2.2 How to connect the cables

Note: If there is a chance of inclement weather when the RF unit is removed, cover the intakes on the front and rear covers with packing tape. Be sure to remove the tape after completing the installation.

Armor Crimp-on lugSheath

SheathSheath

Coaxial cable

Shield

14 5 9

10 30 390390

410410Vinyl tape

270270

SheathSheath

Armor SheathSheath

63010 1270

Crimp-on lug

(FV2-M4)

Wrap spiral tube.

Vinyl tape

ex) Front side

Intake (Cover with packing tape)Intake (Cover with packing tape) 2-4

1. Loosen four bolts on the rear cover, then remove the rear cover, Note: The cable for the performance monitor is connected between the rear cover and the RF-TB Board. Detach the cover slowly to prevent damage to the cable and connector.

2. Disconnect the performance monitor connector (J807) and the motor drive connectors (J803, J804 and J840) from the RF-TB Board.

3. Disconnect the coaxial cable.

4. Unfasten four bolts circled in the right figure to enable remov-al of the RF unit.

5. Remove the RF unit.

Performance monitorPerformance monitor

J807 (for performance monitor)

J807 (for performance monitor)

RF-TB board (03P9570)

J804 (for motor)J804 (for motor)

J803 (for motor) J803 (for motor)

J840 (for motor) J840 (for motor)

Clockwise when viewed from the stern Clockwise when viewed from the stern 2-5

6. Unfasten the cable gland for the antenna cable (RW- 00135) and remove the gas-ket and three flat washers.

7. Slide the cable gland, the gasket and three flat washers onto the cable as shown in the right figure.

8. Push the flat washer against the armor.

9. Trim the armor so that it does not extend past the flat washers, then pass the antenna ca-ble through the cable entrance.

10. If applicable, also pass the cable for the sub monitor and the power cable for the deicer through the cable entrance. Pass the cables through their respective locking wire saddle.

11. Tighten the cable glands with the hook spanner wrench.

Note: Use the wrench of the correct size. If you do not have the hook spanner wrench, contact our dealer.

12. Pull the cables out of the chassis other than the cable for de-icer. See step 13 for the deicer.

13. DE-ICER INSTALLATION. If the de-icer is not provided, go to step 14 on page 2-

8. See "S-band DE-ICER Kit Installation Instructions", issued separately, for the de-icer not fitted at the factory.

1) Remove four bolts then spread open the right and left heater elements on the front cover.

Note: Lift the elements slightly when opening so as not hit the elements on the bolts on the chassis.

Flat washersFlat washers

GasketGasket

Gland for antenna cable Gland for antenna cable

SheathSheath

Cable glandCable gland Flat washerFlat washer GasketGasket

Flat washerFlat washer

Trim the armor.

Push the flat washer against the armor.

Outer sheathOuter sheath

Inner sheathInner sheath

For Antenna cable For Antenna cable

For Sub monitor cable For Sub monitor cable

For power cable of de-icer For power cable of de-icer 2-6

2) Unfasten four bolts to open the front cover. Remove the cover, being careful not to hit the elements on the chassis or radiator.

3) Remove then pass the power cable from the cable entrance. Tighten the ca-ble gland with a hook spaner wrench.

4) Wrap the supplied spiral tube around the power cable for the de-icer, starting from the crimp-on lugs. Set the supplied locking wire saddle at location (6) in the right figure. Pass the cable through locking wire saddles (1) to (6).

5) Unfasten the cable band on the font cover.

Pass the cable for the de-icer through the band then fasten the band. Connect the cable to TB901 on the DE-ICER board (03P9573), using the crimp-on lugs supplied.

6) For 100-115V power supply, set the voltage selection switch to 115V. (default setting: 230V) Turn on the power to the deicer then press the [TEST] button about ten seconds. Check if the heater gets hot. Turn off the power to the de-icer.

7) Fasten the front cover, then fasten the cable entrance for the DE-ICER. When fastening the front cover, spread open the heater elements, lifting the base of the heater. Take care not to hit the heater elements on the chassis or radiator.

Spiral tubeSpiral tube

Cable band

Cable band

Cable band

Cable band

Cable band

03P9573

TB901

[TEST] button[TEST] button

Voltage Selection Switch

TB901

03P9573 Board 2-7

8) Fasten the two heater elements to the chassis. Fasten the base of the heater with two M5 screws (supplied) coated with marine sealant supplied. Fasten the installation materials to each of the cover bolts.

9) Attach the supplied earth label over the earth label attached near the ground-ing terminal.

Note: If it is necessary to open the front cover after installing the DE- ICER kit, remove the power cable from the locking wire saddle in the right figure then detach the cover slowly to prevent damage to the heater.

14. Re-mount the RF unit then reconnect the connectors for the motor (J803, J840 and J804), the four bolts (see step 4) and the coaxial cable (see step 3).

15. Pass the LAN cable of the antenna cable from the cable entrance through two locking wire saddles to the LAN port at the bottom of the RF unit (J821).

16. Attach appropriate WAGO connector (supplied) to both the antenna cable and the cable for the sub monitor. Connect the antenna cable and the cable for the sub monitor to the RF-TB Board as shown below. A terminal opener is provided on the RF-TB Board.

Cover BoltCover Bolt

M5 screwM5 screw

Fixing Shaft Fixing Shaft

SD Heater Fixing Plate SD Heater Fixing Plate

M5 screw coated with marine sealantM5 screw coated with marine sealant

Grounding terminalGrounding terminal

Earth label

Remove the power cable from the locking wire saddle to open the front cover.

Remove the power cable from the locking wire saddle to open the front cover.

Locking wire saddles

Locking wire saddles

LAN portLAN port 2-8

• Antenna cable:

Power: TB801 on RF-TB Board (03P9570)

LAN: J821 on RF-TB board Shields: For the power cable, screw on RF-TB Board (03P9570).

For the LAN cable, screw near the LAN slot.

For the antenna cable RW-9600, connect the crimp-on lug (that binds unused wires) together with the shield of the power ca-ble.

• Cable for sub monitor:

Signal: TB803 on RF-TB board

Coax. cable: TB804 on RF-TB board

Shield: Screw on chassis.

17. Reconnect the performance monitor connector (J807), see step 2 on page 2-5.

18. Check that the gasket on the rear cover is seated properly, then close the covers.

The torque must be 21.0 N•m.

Wire

How to connect wires to WAGO connector Press downward.

Terminal opener

WAGO

connectorTwist

<Procedure>

1. Twist the cores.

2. Press the terminal opener downward.

3. Insert the wire to hole.

4. Remove the terminal opener.

5. Pull the wire to confirm that it is secure.

1 3 6 7 8 9 112 4 5 10

BRN RED ORG YEL GRN BLU PPL WHT

Pin Color

Grounding point for Power cable

Grounding point for Power cable

Grounding point for LAN cable

Grounding point for LAN cable

TB801TB801

TB803TB803

TB804TB804

1 3 6 7 8 9 11 12 13 14 15 162 4 5 10

BRN RED ORG YEL BLKWHT

Pin Color

How to fasten the coaxial cable

NOTICE

Do not use crimp-on lug, to prevent contact resistance from increasing.

Fasten shield with clamp.Fasten shield with clamp.

Fasten conductor with screw.

Fasten conductor with screw.

2-9

2.3 Processor Unit

Note: The interface ports approved for interconnecting navigation equipment are shown in the figure below. For details, see paragraph 2.3.3 "How to select the serial input/output format".

2.3.1 How to connect cables to terminals in the processor unit

Use screws (M3×6, supplied) to attach the wiring plate 1 and wiring plate 2 to the pro-cessor unit. Connect the cables shown below to the connectors at the front of the pro-cessor unit. Bind cables to the appropriate fixing metal with the cable ties (supplied).

For the cables from the monitor unit (type: DVI-D/D SLINK5M/10M* (*: MU-190 only), DSUB9P-X2-L5/10M) and ground wire, connect them to the processor unit directly (without fixing to a wiring plate). Tighten the fixing screws on these connectors to pre-vent disconnection from the processor unit.

Note: Connect the cables so that they do not interfere with the opening or closing of the DVD tray.

J5J5J5

J11J11J11 J4J4J4

J3J3J3J8J8J8

J9J9J9

J10J10J10

J6J6J6

J7J7J7

J12J12J12

J13J13J13 J14J14J14

J3, J4 For IEC 61162-2 or

IEC 61162-1

J5, J6, J7, J8, J9, J10 For IEC 61162-1

Top view of EC-3000

OK UP

Desktop or Bulkhead (Sideway slot) Hanging or Bulkhead (Vertical slot) 2-10