TYP.
LS200
LS300
LS502
LS300
LS502LS502
STONE TYPE 2: NATURAL STONE VENEER
MORTAR JOINT BETWEEN MASONRY UNITS, TYP.
NICHE COVERS, TYP.
PRE-CAST CONCRETE COLUMBARIUM UNITS TYP.
STONE TYPE 1: NATURAL STONE BASE,
TYP.
T.O.W.
T.M.L.
SEE STRUCTURAL
STONE TYPE 1:
NATURAL STONE CAPS, TYP.
STONE TYPE 1: NATURAL STONE BASE VENEER.
ALIGN MORTAR JOINTS AS SHOWN
T.S.W.
SEE LS100
STONE VENEER MORTAR JOINT TO MATCH
CENTERLINE OF PRECAST NICHE UNITS.
60 70 80 90
1 10 20 30 40
TYP.
LS200
LS300
LS502
LS300
LS502LS502
STONE TYPE 2: NATURAL STONE VENEER
MORTAR JOINT BETWEEN MASONRY UNITS, TYP.
NICHE COVERS, TYP.
PRE-CAST CONCRETE COLUMBARIUM UNITS TYP.
STONE TYPE 1: NATURAL STONE BASE,
TYP.
T.O.W.
T.M.L.
SEE STRUCTURAL
STONE TYPE 1:
NATURAL STONE CAPS, TYP.
STONE TYPE 1: NATURAL STONE BASE VENEER.
ALIGN MORTAR JOINTS AS SHOWN
T.S.W.
SEE LS100
STONE VENEER MORTAR JOINT TO MATCH
CENTERLINE OF PRECAST NICHE UNITS.
TYP.
LS200
LS300
LS502
LS300
LS502LS502
STONE TYPE 2: NATURAL STONE VENEER
MORTAR JOINT BETWEEN MASONRY UNITS, TYP.
NICHE COVERS, TYP.
PRE-CAST CONCRETE COLUMBARIUM UNITS TYP.
STONE TYPE 1: NATURAL STONE BASE,
TYP.
T.O.W.
T.M.L.
SEE STRUCTURAL
STONE TYPE 1:
NATURAL STONE CAPS, TYP.
STONE TYPE 1: NATURAL STONE BASE VENEER.
ALIGN MORTAR JOINTS AS SHOWN
T.S.W.
SEE LS100
STONE VENEER MORTAR JOINT TO MATCH
CENTERLINE OF PRECAST NICHE UNITS.
50 60 70 80
1 10 20 30 40
TYP.
LS200
LS300
LS502
LS300
LS502LS502
STONE TYPE 2: NATURAL STONE VENEER
MORTAR JOINT BETWEEN MASONRY UNITS, TYP.
NICHE COVERS, TYP.
PRE-CAST CONCRETE COLUMBARIUM UNITS TYP.
STONE TYPE 1: NATURAL STONE BASE,
TYP.
T.O.W.
T.M.L.
SEE STRUCTURAL
STONE TYPE 1:
NATURAL STONE CAPS, TYP.
STONE TYPE 1: NATURAL STONE BASE VENEER.
ALIGN MORTAR JOINTS AS SHOWN
T.S.W.
SEE LS100
STONE VENEER MORTAR JOINT TO MATCH
CENTERLINE OF PRECAST NICHE UNITS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN MOTION, INC.
COST ESTIMATOR:
TOTAL COST MANAGEMENT
GEOTECHNICAL ENGINEER
TERRACON
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
2026.01.14
C :\U se rs
\ib la nc o\
O ne
D riv e
- A
N D
ER
SO
N E
N G
IN
EE
R
IN
G O
F M
N \D oc um en ts
\1
_l
_c ol um ba riu m
_r
_i bl an co
K8
JU
K.
rv t 1/
/2
4:
:4
PM
COLUMBARIUM COURT 4
ELEVATIONS WALL B1-A1
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
7601 34TH AVE S, MINNEAPOLIS, MN 55450
894CM3044
JANUARY 14, 2026 JAF IBA18511
LS205
SCALE: 1/2" = 1'-0" (30" x 42" PAPER SIZE)1 WALL ELEVATION - B1-1
SCALE: 1/2" = 1'-0" (30" x 42" PAPER SIZE)2 WALL ELEVATION - B1-2
SCALE: 1/2" = 1'-0" (30" x 42" PAPER SIZE)3 WALL ELEVATION - A1-1
SCALE: 1/2" = 1'-0" (30" x 42" PAPER SIZE)4 WALL ELEVATION - A1-2
Revisions: Date:
CAST-IN-PLACE CONCRETE STEM
WALL; (SEE STRUCTURAL).
PRE-CAST CONCRETE
COLUMBARIUM UNITS TYP.
MARBLE NICHE COVERS, TYP. (VA
SUPPLIED / CONTRACTOR INSTALLED)
STONE TYPE 1: NATURAL
STONE CAP, TYP
TOW
SEE LS100
TSW
SEE LS100
TML
SEE STRUCTURAL
LS501
LS502
ANCHORS AS REQUIRED
AND SPECIFIED BY
SPECIALTY ENGINEER
ANCHORS AS REQUIRED
AND SPECIFIED BY
SPECIALTY ENGINEER
A
B
C
D
E
A
B
C
D
E
TOW
SEE LS100
TSW
SEE LS100
TML
SEE STRUCTURAL
STONE TYPE 1: NATURAL
STONE CAP, TYP.
STONE TYPE 2: NATURAL
STONE VENEER, TYP.
AIR GAP
CAST-IN-PLACE CONCRETE
STEM WALL; SEE STRUCTURAL
STONE TYPE 1: NATURAL
STONE VENEER BASE, TYP.
LS501
LS502
THREADED ROD.
SEE STRUCTURAL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN MOTION, INC.
COST ESTIMATOR:
TOTAL COST MANAGEMENT
GEOTECHNICAL ENGINEER
TERRACON
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
2026.01.14
C :\U se rs
\ib la nc o\
O ne
D riv e
- A
N D
ER
SO
N E
N G
IN
EE
R
IN
G O
F M
N \D oc um en ts
\1
_l
_c ol um ba riu m
_r
_i bl an co
K8
JU
K.
rv t 1/
/2
4:
:5
PM
COLUMBARIUM SECTIONS
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
7601 34TH AVE S, MINNEAPOLIS, MN 55450
894CM3044
JANUARY 14, 2026 JAF IBA18511
LS300
SCALE: 1" = 1'-0" (30" x 42" PAPER SIZE)2 DOUBLE-SIDED NICHE WALL SECTION - TYP.
SCALE: 1" = 1'-0" (30" x 42" PAPER SIZE)1 DOUBLE-SIDED COLUMN WALL SECTION - TYP.
GRID
GRID
LS300
LS300
TYP.
LS200
DECORATIVE ROCK MULCH
FLOWER STRIP
PRE-CAST CONCRETE
COLUMBARIUM UNIT;
SEE LS500
CAST IN-PLACE CONCRETE
STEM WALL (TSW); SEE
STRUCTURAL
CONT. VERTICAL
SEALANT JOINT W/
BACKER ROD
THRU-WALL FLASHING (BELOW)
VENEER S2.1. SEE COLUMBARIUM
STONE PROFILES 6/LS503
VENEER B1.1. SEE COLUMBARIUM
STONE PROFILES 6/LS503
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN MOTION, INC.
COST ESTIMATOR:
TOTAL COST MANAGEMENT
GEOTECHNICAL ENGINEER
TERRACON
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
2026.01.14
C :\U se rs
\ib la nc o\
O ne
D riv e
- A
N D
ER
SO
N E
N G
IN
EE
R
IN
G O
F M
N \D oc um en ts
\1
_l
_c ol um ba riu m
_r
_i bl an co
K8
JU
K.
rv t 1/
/2
4:
:5
PM
COLUMBARIUM COLUMN
ENLARGEMENTS
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
7601 34TH AVE S, MINNEAPOLIS, MN 55450
894CM3044
JANUARY 14, 2026 JAF RJL18511
LS400
0 8" 1'-4"4" SCALE: 1 1/2" = 1'-0" (30" x 42" PAPER SIZE)1 COLUMBARIUM END COLUMN ENLARGEMENT, TYP.
SIDE - ELEVATION FRONT - ELEVATION
PRE-CAST COLUMBARIUM NICHE - PROVIDE LIFTING INSERTS,
RE-INFORCING, AND WELD PLATES PER TECHNICAL SPECIFICATIONS
INSTALL ANCHOR BOLTS, WASHERS & EXPANSION SHIELDS PER SUBMITTAL REQUIREMENTS;
FIELD INSTALL & FILL WITH SEALANT FLUSH WITH ADJACENT CONCRETE, TYP.
NICHE COVERS:
PRE-DRILLED
HOLES FOR
ATTACHMENT
ROSETTE (TYP.)
WELD PLATE, SEE 2/LS500
1'- 3"10 1/2"1 1/2"
1 1 /2"
1 1/2"
1 1 /2"
1'-8"
1'- 2 1
/2"
1'- 3"
1 1 /2"
2"
2" 7'-
0"
1'-10"
1 1 /2"
WELD PLATE, SEE
2/LS500 (TYP.)
8' 1-1/2" (5HT X 8W)
1.
2.
A.
B.
C.
D.
PRE-CAST CONCRETE COLUMBARIUM UNITS - DELEGATED
DESIGN REQUIREMENTS:
THE CONTRACTOR SHALL PROVIDE STRUCTURAL
DESIGN OF THE PRE-CAST CONCRETE
COLUMBARIUM UNITS. STRUCTURAL DESIGN SHALL
BE SUBMITTED BY THE CONTRACTOR TO THE
CONTRACTING OFFICER'S REPRESENTATIVE (COR)
AND ENGINEER OF RECORD (EOR) AS A DELEGATED
DESIGN SUBMITTAL. DELEGATED SUBMITTALS SHALL
INCLUDE DRAWINGS AND CALCULATIONS THAT HAVE
BEEN STAMPED AND SIGNED BY AN ENGINEER
APPROPRIATELY LICENSED IN THE STATE OF
CONSTRUCTION,
THE PURPOSE OF THE EOR'S REVIEW SHALL BE
DETERMINING THE DRAWINGS AND CALCULATIONS
HAVE BEEN PROPERLY SEALED, THAT THE LOAD
CRITERIA IS IN GENERAL CONFORMANCE WITH THE
CONTRACT DOCUMENTS AND THE REFERENCED
BUILDING CODE, AND THAT THE CONNECTIONS TO
THE PRIMARY STRUCTURE ARE APPROPRIATE FOR
THE STRUCTURE'S DESIGNED CAPABILITIES.
INCLUDED IN THE STRUCTURAL CALCULATIONS AND
DESIGN AT MINIMUM SHALL BE:
DESIGN OF PRE-CAST CONCRETE COLUMBARIUM
UNITS.
CONNECTION OF THE PRE-CAST UNITS TO
STRUCTURAL FOUNDATIONS, BOTTOM AND TOP.
CONNECTION OF PRE-CAST UNITS BACK TO BACK
AND END TO END.
CONNECTION OF PRE-CAST UNITS TO NATURAL
STONE CAPS.
REFER TO SPECIFICATION 03 48 24 - PRE-CAST
CONCRETE COLUMBARIUM UNITS AND S001 FOR
ADDITIONAL INFORMATION.
3.
1" DIA. STAINLESS STEEL
ROSETTE W/ NEOPRENE WASHER
SEE 7/LS500
STAINLESS
STEEL TAMPER-
RESISTANT TORX
PIN HEAD BOLT
SEE 7/LS500
PLASTIC WASHER
STAINLESS
STEEL CLIP
ANGLE
ASSEMBLY /
MOUNTING
BRACKET; SEE
8/LS500
S.S. WASHER
S.S. WASHER &
LOCKWASHER
S.S. BOLT & HEX NUT,
1/4"-20 X 2 1/2" LONG
S.S. SPRING CLIP
S.S. SPRING CLIP
MATCH EXISTING STAINLESS STEEL ROSETTE
(VA STANDARD); SATIN FINISH.
PROVIDE PRODUCT LITERATURE & SAMPLE
FOR APPROVAL.
NEOPRENE WASHER
3/16" x 1 3/4" LENGTH
STAINLESS STEEL TAMPER-
RESISTANT TORX PIN HEAD
BOLT
FRONT ELEVATION
SECTION
8 - PETAL ROSETTE
DI
A.1"
THREADED SPRING CLIP TO RECEIVE
ROSETTE BOLT.
5/16" x 3/4" SLOTS
SIDE VIEW FRONT VIEW PLAN VIEW
3/32" THICK STAMPED
ANGLE BRACKET W/
(2) SLOTS
1 1 /2"
1 1/4"
1/2
3/4" 3/4"
1/2
/12
8"
9/6 4"
3/3 2"
R 3/6
4"
1/2"
EQ
EQ
THREADED SPRING CLIP
SIDE VIEWPLAN VIEW
CL
CL
CL
CL
CL
CL
ROSETTE
FASTENER, TYP.
NICHE COVER
PLATE, TYP.
NICHE COVER
MOUNTING
BRACKETS,
TYP.
PRECAST
COLUMBARIU
M NICHE UNIT,
TYP.
3/4"
3/4"
10 1/2"
3/4"
3/4"
1'-0"
1'- 3 3
/4" 3/4
3/4
1'-
2 1 /4"
3/4
3/4
LS500
TYP TYP. CONDITION AT INTERMEDIATE
SHELVES OF PRE-CAST UNIT
3/8" DIAMETER X 3" THREADED ROD, LOCK
WASHER & HEX NUTS & PLASTIC SHIMS
ROSETTE AND BOLT, TYP.
1/2" DIAMETER CAST IN PLACE
HOLE, TYP.
ROSETTE AND BOLT, SEE
DETAIL 7/LS500
NICHE COVER MOUNTING
BRACKET, SEE DETAIL 6/LS500
NICHE COVERS W/ PREDRILLED
7/16" DIA. HOLES TO ACCEPT
ROSETTE & BOLT - COVERS
ARE 11 1/4" WIDTH x 1' 3 3/4" HEIGHT x 3/4" THICK
7/8" DIAMETER, 1/16" THICK
CLEAR WASHER, TYP. (2) FOR
EACH ROSETTE
ROSETTE AND BOLT (TYP.)
THROUGH 7/16" DIAMETER PRE-
DRILLED HOLE
ALL EXPOSED CONCRETE (NICHE
FRONTS) SHALL BE GROUND OR
PATCHED SMOOTH; APPLY 2
COATS SPECIFIED HIGH BOND
SEALER SUPER COLOR COATING
1/2" DIAMETER CAST IN PLACE HOLE
PLASTIC SHIMS, TYP.
1/4" x 1 3/4"
EXPANSION BOLT,
LOCK WASHER &
HEX NUT, TYP.
LS500
8 TYP
FRONT - ELEVATION SIDE - SECTION
LS500
TYP
LS500
TYP
5A
5B
EMBEDDED WELD
PLATE, TYP.
S.S. WELD PLATE
PRECAST COLUMBARIUM
UNIT PRECAST CONCRETE
COLUMBARIUM UNIT, TYP.
EMBEDDED WELD
PLATE, TYP.
WELD PLATE
END COLUMN, SEE PLANS FOR
ADDITIONAL INFORMATION, TYP.
PRECAST COLUMBARIUM
UNIT, TYP.
WELD PLATE, RECESSED 1/4"
EMBEDDED WELD PLATE W/
NELSON STUD, TYP.
NATURAL STONE CAP
PLAN VIEW:
BACK TO BACK PRECAST
COLUMBARIUM
PLAN VIEW:
BACK TO BACK PRECAST
COLUMBARIUM TO END COLUMN
SECTION A-A' VIEW:
END COLUMN / STEM WALL CONNECTION
SECTION B-B' VIEW:
DOUBLE SIDED PRECAST
COLUMBARIUM CONNECTION
VARIES
VA
RI
ES
VA
RI
ES
VARIES
VARIES
VA
RI
ES
VARIES
A-A'
B-B'
NATURAL STONE CAP
WELD PLATE, RECESSED 1/4"
FROM TOP OF PRECAST UNIT
END COLUMN / STEM WALL, SEE
PLANS FOR ADDITIONAL
INFORMATION, TYP.
EMBEDDED WELD PLATE
W/ NELSON STUD, TYP.
PRECAST CONCRETE
COLUMBARIUM UNIT, TYP.
OVERALL COVER
11 1/4"
INSIDE NICHE FACE
10 1/2"
OV
ER
AL
L C
OV
ER
1'- 3 3
/4"
IN
SI
DE
N
IC
HE
F
AC
E 1'-
3"
1 1/4"
1/
4"
3/4" THICK BLANK
NICHE COVER
PLATE.
3/8" DIA. PRE-DRILLED
HOLE TO ACCEPT
BOLTS AND ROSETTES,
(4) TYPICAL DIA.
COORDINATE SIZE OF
HOLE WITH 3/16"
ROSETTE FASTENERS
EQ
EQ
EQ EQ
IN
SI
DE
N
IC
HE
B
AC
K 1'-
2 1 /2"
INSIDE NICHE FACE
10"
ALL EDGES OF THE
FRONT, BACK, AND
CORNERS SHALL BE
SMOOTH SAWN AND
FINISHED WITH A
CLEAN 1/8" ARIS
(EASED EDGE)
NOTE:
NICHE COVER TO BE PROVIDED BY GOVERNMENT & INSTALLED BY
CONTRACTOR
CL
C L
1/4" DIA. HOLE, CAST IN
PLACE - HOLE NOT TO
EXTEND THRU NICHE WALL
1/4" x 1 1/2" EXPANSION
BOLT, LOCK WASHER &
HEX NUT
1/4" DIA. HOLE, CAST IN
PLACE, TYP.
PLASTIC SHIMS, TYP.
1/4" x 1 3/4" EXPANSION
BOLT, LOCK WASHER &
HEX NUT
ALL EXPOSED NICHE FRONTS
SHALL BE A SMOOTH
SURFACE
NICHE COVERS W/ PRE-
DRILLED 3/8" DIA. HOLES TO
ACCEPT ROSETTE & BOLT
3/4" DIA. WASHER, TYP.
LS500
TYP
LS500
TYP
3/8
3/8
3/4
3/2
NOTE: SEE 6/LS500
FOR ISOMETRIC VIEW
TYPE 5B
TYPE 5A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN MOTION, INC.
COST ESTIMATOR:
TOTAL COST MANAGEMENT
GEOTECHNICAL ENGINEER
TERRACON
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
2026.01.14
C :\U se rs
\ib la nc o\
O ne
D riv e
- A
N D
ER
SO
N E
N G
IN
EE
R
IN
G O
F M
N \D oc um en ts
\1
_l
_c ol um ba riu m
_r
_i bl an co
K8
JU
K.
rv t 1/
/2
4:
:5
PM
COLUMBARIUM PRECAST
DETAILS
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
7601 34TH AVE S, MINNEAPOLIS, MN 55450
894CM3044
JANUARY 14, 2026 JAF RJL18511
LS500
SCALE: 12" = 1'-0" (30" x 42" PAPER SIZE)6 NICHE COVER MOUNTING BRACKET - ISOMETRIC
SCALE: 3/4" = 1'-0" (30" x 42" PAPER SIZE)1 PRE-CAST COLUMBARIUM NICHE UNIT - 5 HIGH DETAIL
SCALE: 12" = 1'-0" (30" x 42" PAPER SIZE)7 ROSETTE FASTENER DETAIL SCALE: 12" = 1'-0" (30" x 42" PAPER SIZE)8 NICHE COVER MOUNTING BRACKET (S.S. CLIP ANGLE ASSEMBLY)
SCALE: 3" = 1'-0" (30" x 42" PAPER SIZE)3 NICHE COVER PLATE ATTACHMENT
SCALE: 1" = 1'-0" (30" x 42" PAPER SIZE)2 PRECAST COLUMBARIUM UNIT WELD PLATE DETAILS
SCALE: 3" = 1'-0" (30" x 42" PAPER SIZE)4 NICHE COVER PLATE (VA PROVIDED) / (CONTRACTOR INSTALLED) SCALE: 6" = 1'-0" (30" x 42" PAPER SIZE)5 NICHE COVER ATTACHMENT SECTION
NICHE COVER
PRECAST COLUMBARIUM
UNIT ANCHOR AS
REQUIRED BY
SPECIALTY ENGINEER
PRE-CAST COLUMBARIUM
UNIT
HORIZONTAL CELL VENT
INSTALLED 16" O.C. FROM
EACH END OF PRE-CAST
UNIT.
3/8" SEALANT W/BACKER
ROD
DECORATIVE ROCK MULCH
FLOWER STRIP
CAST-IN-PLACE STEM
WALL (SEE STRUCTURAL)
THICKENED EDGE CONCRETE
PAVEMENT; SEE 9/CS503
FREE-DRAINING AGGREGATE/
GRANULAR DRAINAGE BACKFILL
WRAP DRAINAGE FILL WITH NON-
WOVEN GEOTEXTILE FABRIC.
OVERLAP @ TOP 6" MIN.
HDPE PERFORATED DRAINTILE;
(SEE UTILITY PLAN)
STONE TYPE 1: 4" BASE STONE;
MORTARED SOLID IN PLACE
DAMP PROOFING HOLD DOWN 3"
BELOW FINISH GRADE; EXTEND
DAMP PROOFING DOWN TO TOP
OF FOOTING
/4
3/ 8"
2"
VA
RI
ES
1"
8" 9 3
/4"
MI
N 1/4
STONE TYPE 2
3/8" CONCAVE MORTAR JOINT
SEALANT
CONTINUOUS TERMINATION BAR
MORTAR MESH IN AIRSPACE, MIN 18"
HEIGHT OF WALL/COLUMN
TYPE 1 CELL VENT, (BEYOND) AT EACH JOINT
MORTAR HAUNCH
CONTINUOUS SELF ADHESIVE EPDM
THRU WALL FLASHING
3/8" MORTAR AT BOTTOM
STONE TYPE 1
1/2" EXPANSION JOINT
VA
RI
ES
THICKENED EDGE CONCRETE
PAVEMENT; SEE 9/CS503
3/8
1/
4"
" M
IN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN MOTION, INC.
COST ESTIMATOR:
TOTAL COST MANAGEMENT
GEOTECHNICAL ENGINEER
TERRACON
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
2026.01.14
C :\U se rs
\ib la nc o\
O ne
D riv e
- A
N D
ER
SO
N E
N G
IN
EE
R
IN
G O
F M
N \D oc um en ts
\1
_l
_c ol um ba riu m
_r
_i bl an co
K8
JU
K.
rv t 1/
/2
4:
:5
PM
COLUMBARIUM TYPICAL
DETAILS
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
7601 34TH AVE S, MINNEAPOLIS, MN 55450
894CM3044
JANUARY 14, 2026 JAF RJL18511
LS501
SCALE: 3" = 1'-0" (30" x 42" PAPER SIZE)1 NICHE WALL BASE DETAIL, TYP.
SCALE: 3" = 1'-0" (30" x 42" PAPER SIZE)2 COLUMN BASE DETAIL, TYP.
ANCHORS AS DESIGNED AND
REQUIRED BY THE PRE-CAST
CONCRETE COLUMBARIUM UNIT
SPECIALTY ENGINEER.
1/2" SEALANT W/BACKER ROD,
CONT. ALONG CAP JOINT.
PRECAST NICHE UNITS,
WHERE APPLICABLE
CAP WIDTH
TYP.
1'-0" OVERHANG
HE
IG
HT
SL
AB HE
IG
HT
PE
AK
LS502
THREADED ROD ANCHORS -
SEE STRUCTURAL
1/2" SEALANT W/BACKER ROD,
CONT. ALONG CAP JOINT.
CONTINUOUS SELF
ADHESIVE EPDM
CAST-IN-PLACE CONCRETE.
STEM WALL, SEE PLANS
STONE VENEER
2"
HE
IG
HT
SL
AB HE
IG
HT
PE
AK
CAP WIDTH
LS502
EXTEND DAMP PROOFING 2" MIN.
ON TOP OF CIP CONCRETE.
WALL
TYPE 1 WEEP VENT (HORIZONTAL).
PLACE AT EVERY CAP JOINT (BEYOND)
CONT. SELF ADHESIVE EPDM
MEMBRANE, HOLD MEMBRANE
BACK 1/2" FROM FACE
TYPE 1 WEEP VENT (VERTICAL).
WEEP VENT SHALL NOT EXTEND PAST
STONE VENEER FACE, SPACE
LONGITUDINALLY EVERY 24"-36".
STONE TYPE 1: CAP
3/8" BACKER ROD AND
SEALANT
STONE TYPE 2 VENEER
CONT. SELF-ADHESIVE EPDM
MEMBRANE, OVERLAP 3", HOLD
BACK 1/2" FROM FACE, SET STONE
CAP IN MORTAR/GROUT BED.
THRU-WALL FLASHING
FT1/2"
3" MIN.
CL
DRIP EDGE
CONTINUOUS
AROUND CAP
1/2" 1"3/ 8"
1/4"
CONTINUOUS 1/2"
SEALANT
W/BACKER ROD
ALONG CAP SEAM
LS502
TYP
STONE TYPE1 : CAP
CONTINUOUS SELF
ADHESIVE EPDM
MORTAR & SHIMS AS
NECESSARY
TYPE 1 HORIZONTAL
CELL VENTS; LOCATE
AT EACH CAP JOINT
12" OVERHANG
3/8"
HORIZ CELL VENT
STONE CAP
JOINT SEALANT
BACKER ROD
3/8
T.O. NICHE UNIT
SELF-ADHERING
EPDM FLASHING
CROSS SECTION
128"
NUMBERS 8" HIGH, BEVEL CUT MATCH
DEPTH & CUT WIDTH TO COLUMBARIA
1, CENTER IDENTIFICATION NUMBERS
WITHIN MASONRY UNIT. FONT TO BE
OPTIMA, TYP. FOR ADDRESSING SEE
SHEET LS140; FOR PLACEMENT SEE
9/LS502
COLUMBARIA COURT IDENTIFICATION
LETTERING
TE
XT
H
EI
G H
T
1.
2.
3.
4.
5.
NOTES:
OPTIMA FONT TO MATCH EXISTING COLUMBARIA
ALL CHARACTERS TO BE SANDBLASTED TO A DEPTH OF 3/8" IN STONE
VENEER.
SEE ELEVATIONS FOR ROW INDICATOR LOCATIONS.
SEE ADDRESSING PLANS LS140 FOR COLUMN MARKER AND WALL ID
LOCATIONS
COLUMBARIUM COURTYARD IDENTIFICATION NUMBERS TO BE
SANDBLASTED INTO STONE VENEER. CENTER IDENTIFICATION NUMBERS
WITHIN MASONRY UNIT. SEE 3/LS200 FOR DETAILS.
A 4"
ROW ID MARKER
LETTERS 2" HIGH, BEVEL CUT MATCH
DEPTH & CUT WIDTH TO COLUMBARIA 1.
CENTER HORIZONTALLY AND
VERTICALLY AS SHOWN. FONT TO BE
OPTIMA AS SHOWN. FOR ADDRESSING,
SEE SHEET LS140; FOR PLACEMENT
SEE 10/LS502
10 4"
NICHE COLUMN NUMBERING
NUMBERS 2" HIGH, BEVEL CUT MATCH
DEPTH & CUT WIDTH TO COLUMBARIA 1,
CENTERED VERTICALLY AND
HORIZONTALLY ABOVE FIRST AND 10TH
COLUMN OF EACH NICHE BANK, EACH
SIDE. FONT TO BE OPTIMA AS SHOWN.
FOR ADDRESSING, SEE SHEET LS140; FOR
PLACEMENT SEE 8/LS502
COLUMBARIUM
NICHE COVER
FACE OF STONE CAP10
EQ
EQ
8"
LS502
EQ EQ
COLUMBARIUM WALL
NUMBER BEVEL CUT MATCH
DEPTH & CUT WIDTH TO
COLUMBARIA 1.CENTER
IDENTIFICATION NUMBERS
WITHIN MASONRY UNIT.
FONT TO BE OPTIMA TYP.
FOR ADDRESSING. NUMBERS
TO MATCH ASSOCIATED
WALL AND SIDE OF WALL.
REFER TO LS140 AND 6/LS502 12
EQ EQ
EQ
EQ
STONE TYP 2:
NATURAL
STONE VEENER
A
B
C
D
E
NICHE WALL
ID NUMBER
CL
CL
CL
CL
CL
A
B
C
D
E
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
2" TYP.
EQ EQ
EQ EQ EQ EQ
EQ EQ
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN MOTION, INC.
COST ESTIMATOR:
TOTAL COST MANAGEMENT
GEOTECHNICAL ENGINEER
TERRACON
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
2026.01.14
C :\U se rs
\ib la nc o\
O ne
D riv e
- A
N D
ER
SO
N E
N G
IN
EE
R
IN
G O
F M
N \D oc um en ts
\1
_l
_c ol um ba riu m
_r
_i bl an co
K8
JU
K.
rv t 1/
/2
4:
:0
PM
COLUMBARIUM CAP DETAILS
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
7601 34TH AVE S, MINNEAPOLIS, MN 55450
894CM3044
JANUARY 14, 2026 JAF RJL18511
LS502
SCALE: 1 1/2" = 1'-0" (30" x 42" PAPER SIZE)1 CAP SETTING SECTION DETAIL, TYP SCALE: 1 1/2" = 1'-0" (30" x 42" PAPER SIZE)2 CAP SETTING SECTION DETAIL, DOUBLE-SLOPE CAP
SCALE: 3" = 1'-0" (30" x 42" PAPER SIZE)3 COLUMN CAP SETTING DETAIL, TYP.
SCALE: 6" = 1'-0" (30" x 42" PAPER SIZE)5 CAP DRIP EDGE DETAIL, TYP SCALE: 3" = 1'-0" (30" x 42" PAPER SIZE)4 NICHE UNIT CAP SETTING DETAIL, TYP.
SCALE: 6" = 1'-0" (30" x 42" PAPER SIZE)6 NATURAL STONE CAP JOINT DETAIL, TYP.
SCALE: 1 1/2" = 1'-0" (30" x 42" PAPER SIZE)8 COLUMN ID MARKER, TYP.
SCALE: 1 1/2" = 1'-0" (30" x 42" PAPER SIZE)7 COLUMBARIUM WALL LETTERING AND NUMBERING
SCALE: 1" = 1'-0" (30" x 42" PAPER SIZE)9 COLUMBARIUM WALL IDENTIFICATION LETTERING, TYP.
SCALE: 1/2" = 1'-0" (30" x 42" PAPER SIZE)10 ROW ID MARKER, TYP.
LS502
C2.1-PLAN
VERTICAL
FACE BELOW
C2.1-RIGHT
LENGTH
8'-1 1/2"
W
ID
TH
5' -9
O
VE
R H
AN
G
1' -0
O
VE
R H
AN
G
1' -0
RIDGELINE
VERTICAL
FACE BELOW
VERTICAL
FACE BELOW
C2.2-PLAN
C2.2-RIGHT
PE
AK
"SL
AB8"
W
ID
TH
5'
9"
LENGTH
1' - 8"
O
VE
R H
AN
G
2" O
VE
R
H
AN
G 2"
OVERHANG
2"
SL
AB8"
PE
AK
B1.2 - FRONT
LENGTH
1' - 1 5/8"
H
EI
G H
T
/4
WIDTH
4"
B1.2 - SIDE
B1.1 - FRONT
LENGTH
5' - 5"
H
EI
G H
T
/4
WIDTH
4"
B1.1 - SIDE
2"
3"ANGLED
REVEAL
2' - 5 1/2" 6" 2' - 5 1/2"
B1.3 - FRONT
LENGTH
11 5/8"
H
EI
G H
T
/4
WIDTH
4"
B1.3 - SIDE
B1.4 - FRONT
LENGTH
4' - 0 9/16"
H
EI
G H
T
/4
WIDTH
4 1/2"
B1.4 - SIDE
S1.2 - FRONT
LENGTH
2' - 1 1/8"
S1.2 - SIDES1.1 - FRONT
LENGTH
5 1/4"
H
EI
G H
T
1'
1/
WIDTH
2"
S1.1 - SIDE
WIDTH
4"
H
EI
G H
T
1'
1/
S1.4 - FRONT
LENGTH
1' - 4"
S1.4 - SIDES1.3 - FRONT
LENGTH
1' - 1 5/8"
H
EI
G H
T
1'
1/
WIDTH
4"
S1.3 - SIDE
WIDTH
4"
H
EI
G H
T
1'
1/
S2.1 - FRONT
LENGTH
5 1/4"
H
EI
G H
T
1'
1/
8"
WIDTH
2"
S2.1 - SIDE S2.2 - FRONT
LENGTH
1' - 2 9/16"
H
EI
G H
T
1'
1/
8"
WIDTH
4"
S2.2 - SIDE S2.3 - FRONT
LENGTH
1' - 1 5/8"
H
EI
G H
T
1'
1/
8"
WIDTH
4"
S2.3 - SIDE S2.4 - FRONT
LENGTH
11 5/8"
H
EI
G H
T
1'
1/
8"
WIDTH
4"
S2.4 - SIDE
S1.3
S2.3
S1.3S1.3
S2.3
S1.3 S1.1
S2.1
S2.1
S1.1
B1.1
S1.2
S2.2 S2.2
S2.5
S2.2S2.2
S1.2S1.2
S2.2 S2.2
S2.5
S2.2 S2.2
S1.2
C2.1
S2.1
TML
TSW
TOW C2.1
B1.3B1.3
S1.4
S2.4
S2.6
S2.4
S1.4 S1.4
S2.4
S2.6
S2.4
S1.4
S2.3
S2.3
B1.2B1.2
S2.3
S2.3
TML
TSW
TOW
LS503
TYP.
S1.3
S2.3
S2.3
S2.3
S1.3
S1.3
S2.3
S2.3
S2.3
S1.3
S1.4
S2.6
S1.4
S2.2
S2.2
S1.4
S2.6
S1.4
S2.2
S2.2
C2.2 C2.1C2.2C2.1
B1.2 B1.4 B1.4 B1.4 B1.4 B1.2 B1.1 B1.1
3/8"TYP.
TYP.
LS503
TOW
TSW
TML
STONE CAP PROFILES
BASE (TYPE 1) STONE PROFILES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN MOTION, INC.
COST ESTIMATOR:
TOTAL COST MANAGEMENT
GEOTECHNICAL ENGINEER
TERRACON
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
2026.01.14
C :\U se rs
\ib la nc o\
O ne
D riv e
- A
N D
ER
SO
N E
N G
IN
EE
R
IN
G O
F M
N \D oc um en ts
\1
_l
_c ol um ba riu m
_r
_i bl an co
K8
JU
K.
rv t 1/
/2
4:
:0
PM
COLUMBARIUM STONE
PROFILES
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
7601 34TH AVE S, MINNEAPOLIS, MN 55450
894CM3044
JANUARY 14, 2026 JAF RJL18511
LS503
VENEER (TYPE 2) STONE PROFILES
STONE CAP SCHEDULE
CAP TYPE WIDTH LENGTH
SLAB
THICKNESS
PEAK
HEIGHT QUANTITY
C2.1 5'-9" 1'-8" 8" 11" 24 C2.2 5'-9" 8'-1 1/2" 8" 11" 57
STONE TYPE-1 BASE STONE SCHEDULE
STONE TYPE LENGTH WIDTH HEIGHT QUANTITY
B1.1 5'-5" 4" 11 1/4" 24 B1.2 1'-1 5/8" 4" 11 1/4" 48 B1.3 11 5/8" 4" 11 1/4" 48 B1.4 4'-0 9/16" 4 1/2" 11 1/4" 228
STONE TYPE-2 VENEER SCHEDULE
STONE TYPE LENGTH WIDTH HEIGHT QUANTITY
S1.1 5 1/4" 2" 1'-5 1/16" 48 S1.2 2'-1 1/8" 4" 1'-5 1/16" 96 S1.3 1'-1 5/8" 4" 1'-5 1/16" 96 S1.4 1'-4" 4" 1'-5 1/16" 96 S2.1 5 1/4" 2" 1'-4 1/8" 72 S2.2 1'-2 9/16" 4" 1'-4 1/8" 192 S2.3 1'-1 5/8" 4" 1'-4 1/8" 144 S2.4 11 5/8" 4" 1'-4 1/8" 96 S2.5 2'-1 1/8" 4" 1'-4 1/8" 48 S2.6 1'-4" 4" 1'-4 1/8" 48
SCALE: 1/2" = 1'-0" (30" x 42" PAPER SIZE)2 END COLUMN STONE ELEVATION TYP.
SCALE: 1/2" = 1'-0" (30" x 42" PAPER SIZE)3 COLUMBARIUM STONE SECTION ELEVATION, TYP.
SCALE: 1/2" = 1'-0" (30" x 42" PAPER SIZE)1 COLUMBARIUM STONE ELEVATION TYP. 4
NOTE: IF THERE IS A DISCREPANCY BETWEEN THE
QUANTITY OF STONE SHOWN ON THE PLAN AND THE
QUANTITY SHOWN IN THE SCHEDULE ABOVE, THE
QUANTITY OF STONE SHOWN ON THE PLAN SHALL TAKE
PRECEDENCE.
GENERAL CONSTRUCTION NOTES:
1. ALL WORK SHALL COMPLY WITH THE PG-18-10 STRUCTURAL DESIGN MANUAL DATED
7/1/2023 AS APPROVED BY THE DEPARTMENT OF VETERANS AFFAIRS. THE FOLLOWING
CODES APPLY:
-INTERNATIONAL BUILDING CODE 2024
-ASCE/SEI 7-22
-VA HANDBOOK H-18-8 SEISMIC DESIGN REQUIREMENTS
2. REFERENCE STANDARDS: UNLESS OTHERWISE NOTED (U.O.N.), ALL STANDARDS SHALL
BE CURRENT EDITION, WITH LATEST ADDENDA, IF APPLICABLE.
3. THE CONTRACTOR SHALL VERIFY ALL CONTRACT DOCUMENTS, SITE ELEVATIONS,
DIMENSIONS AND CONDITIONS PRIOR TO STARTING WORK AND SHALL NOTIFY THE
ARCHITECT/ ENGINEER OF ANY DISCREPANCIES OR INCONSISTENCIES.
4. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES.
5. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE
FINISHED STRUCTURE. UNLESS OTHERWISE INDICATED, THEY DO NOT INDICATE THE
MEANS OR METHOD OF CONSTRUCTION. TEMPORARY BRACING AND SHORING AGAINST
WIND AND ERECTION CONDITIONS DURING CONSTRUCTION OF THE BUILDING, SHALL BE
THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS SOLELY
RESPONSIBLE FOR THE PROTECTION OF THE STRUCTURE DURING ALL PHASES OF
DEMOLITION, CONSTRUCTION, AND INSTALLATION.
6. NO AREA OF THE STRUCTURE SHALL BE LOADED WITH CONSTRUCTION MATERIALS OR
EQUIPMENT THAT EXCEEDS FINAL DESIGN CRITERIA.
7. VERIFY LOCATION OF BOX OUTS AND OPENINGS WITH MECHANICAL CONTRACTORS.
OPENING SIZES AND LOCATIONS SHOWN FOR PIPES, DUCTS ETC. ARE FOR GENERAL
INFORMATION ONLY AND SHALL BE VERIFIED WITH THE MECHANICAL CONTRACTOR
BEFORE COMMENCING THE WORK.
8. IF MECHANICAL AND ELECTRICAL EQUIPMENT SIZES, WEIGHTS, OR LOCATIONS DO NOT
COINCIDE WITH EQUIPMENT SHOWN ON PLANS, COORDINATE ADJUSTMENTS WITH THE
STRUCTURAL ENGINEER.
9. HOLES, PIPES, SLEEVES, ETC. NOT SHOWN ON THE DRAWINGS MUST BE APPROVED BY
THE STRUCTURAL ENGINEER BEFORE PLACEMENT THROUGH STRUCTURAL MEMBERS.
10. CONTRACTOR SHALL PROVIDE A CAST-IN SLEEVE FOR ALL HORIZONTAL ELEMENTS
THAT EXTEND THROUGH FOOTING. IE: DRAIN TILE, ELECTRICAL CONDUIT, MECHANICAL
PIPING, ETC. ALL SLEEVES SHALL BE COORDINATED WITH ARCHITECT/ENGINEER.
11. SHOP DRAWINGS PREPARED BY SUPPLIERS, SUBCONTRACTORS, ETC., SHALL BE
DIMENSIONED, REVIEWED, COORDINATED, AND SIGNED/ STAMPED BY THE GENERAL
CONTRACTOR PRIOR TO SUBMITTING TO THE STRUCTURAL ENGINEER.
12. FABRICATOR SHALL CLEARLY NOTE CHANGES MADE IN THE SHOP DRAWINGS WHICH DO
NOT COMPLY WITH THE CONTRACT DOCUMENTS. REVIEWED APPROVAL SHOP
DRAWINGS SHOWING ENGINEERS COMMENTS ACCOMPANIED WITH RECORD SET SHOP
SHOP DRAWINGS, SHALL BE AVAILABLE FOR REFERENCE AT THE CONSTRUCTION SITE.
13. CONCRETE ANCHORS SHALL BE SIMPSON 'TITEN HD" SCREW ANCHORS OR EQUIVALENT
(U.O.N.). INSTALL ANCHORS USING THE MANUFACTURER'S RECOMMENDATIONS.
FOUNDATION NOTES:
1. FOOTING ELEVATIONS ARE TO TOP OF FOOTING (T.O. FTG.), UNLESS OTHERWISE
NOTED.
2. FOOTINGS ARE DESIGNED FOR A MINIMUM NET ALLOWABLE SOIL BEARING
PRESSURE OF3000 psf FOR CONTINUOUS AND 3000 psf FOR PAD FOOTINGS.
FOUNDATION DESIGN COMPLIES W/ GEOTECHNICAL REPORT DATED: JUNE 13, 2025
BY TERRACON
3. FOOTINGS SHALL BEAR ON NATURAL UNDISTURBED SOIL OR ENGINEERED FILL.
SOILS SHALL BE OBSERVED AND APPROVED BY A GEOTECHNICAL ENGINEER
PRIOR TO PLACEMENT OF FOOTING CONCRETE. IF NATURAL UNDISTURBED SOILS
ARE NOT ENCOUNTERED AND/OR INADEQUATE SOILS ARE NOTED AT FOOTING
BEARING LEVEL, ARCHITECT/ENGINEER SHALL BE NOTIFIED PRIOR TO
PROCEEDING WITH FURTHER WORK AT THOSE FOOTING LOCATIONS.
4. PROTECT FOOTINGS FROM THE ACTION OF WATER OR FREEZING.
5. FOOTINGS ARE CENTERED UNDER WALLS ABOVE - UNLESS OTHERWISE NOTED.
6. PRIOR TO PLACEMENT OF FOOTING CONCRETE, CLEAN FOOTING EXCAVATIONS OF
SNOW, WATER AND DEBRIS.
7. FOOTINGS MAY NOT BE EARTH FORMED.
EXCAVATION & BACKFILL NOTES:
1. EXCAVATION AND BACKFILL SHALL BE EXECUTED IN ACCORDANCE WITH THE
PROJECT SPECIFICATIONS.
2. BACKFILL, & COMPACTION SHALL BE INSPECTED AND CERTIFIED BY A LICENSED
GEOTECHNICAL ENGINEER. REPORTS ARE TO BE SUBMITTED TO THE
ARCHITECT/ ENGINEER.
3. FOOTING EXCAVATIONS SHALL BE EXCAVATED TO PROPER LINE AND LEVEL TO
ENSURE MINIMUM CONCRETE COVER OF FOOTING REINFORCEMENT FOR
FOOTING DEPTH.
4. BACKFILL SHALL BE COMPACTED BY MECHANICAL MEANS. FLOODING OR
WATER INUNDATION SHALL NOT BE PERMITTED.
5. BACKFILL SHALL BE PLACED IN ALTERNATING LIFTS ON EACH SIDE OF THE
FOUNDATION WALLS TO MAINTAIN STABILITY OF THE FOUNDATION WALLS.
6. BACKFILL SHALL NOT BE PLACED AGAINST BASEMENT FOUNDATION WALLS
UNLESS WALLS ARE ADEQUATELY BRACED TOP AND BOTTOM. FINAL WALL
BRACING IS BASEMENT SLAB OR ENGINEERED BACKFILL AND 1ST FLOOR
STRUCTURE. IF THESE ELEMENTS ARE NOT IN PLACE AT TIME OF BACKFILL,
CONTRACTOR SHALL PROVIDE AN ENGINEERED, TEMPORARY BRACING
SYSTEM. THE TEMPORARY BRACING SYSTEM PROPOSED SHALL BE SUBMITTED
TO THE ARCHITECT/ ENGINEER FOR REVIEW PRIOR TO BACKFILLING.
CONCRETE NOTES:
1. CONCRETE CONSTRUCTION SHALL CONFORM TO AMERICAN CONCRETE
INSTITUTE (ACI) CODES AND SPECIFICATIONS, LATEST EDITION. ACI 301
"SPECIFICATIONS FOR STRUCTURAL CONCRETE" ACI 315 "DETAILS &
DETAILING OF CONCRETE REINFORCEMENT" ACI 318 "BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE".
2. CONCRETE MIX DESIGN SHALL BE BY AN INDEPENDENT TESTING
LABORATORY.
3. CAST-IN-PLACE CONCRETE SHALL BE SUBJECT TO TESTING BY AN
INDEPENDENT TESTING LABORATORY. SEE PROJECT SPECIFICATIONS
FOR REQUIREMENTS.
4. NON WELDED REINFORCING STEEL SHALL BE GRADE 60 DEFORMED,
BILLET-STEEL, ASTM A615, U.O.N. ALL WELDED WIRE FABRIC (WWF)
SHALL BE PLAIN, ASTM A185.
5. WELDED REINFORCING STEEL SHALL BE GRADE 60, LOW CARBON, ASTM
A706.
6. PROVIDE EXTRA REINFORCEMENT AROUND ALL OPENINGS GREATER
THAN 12" SQUARE OR 12" IN DIAMETER, INCLUDING DOOR OPENINGS, IN
CONCRETE WALLS & SLABS. PROVIDE 2 - #5 BARS @ 3" O.C., ON EACH
SIDE OF THE OPENING EXTENDING 24" BEYOND THE CORNER OF THE
OPENING & 2 - #5 BARS AT 3" O.C. BY 3'-0" LONG DIAGONAL BARS AT EACH
CORNER. PLACE DIAGONAL BARS CENTERED ON CORNER @ 2" CLEAR
OF CORNER. ADDITIONAL REINFORCEMENT SHALL BE PROVIDED AT EACH
LAYER OF REINFORCING.
7. REINFORCING STEEL SHALL BE BENT, SPLICED, AND PLACED IN
ACCORDANCE WITH THE ACI 301 (LATEST EDITION).
8. PROVIDE ADEQUATE SUPPORT BARS AND ACCESSORIES TO HOLD
REINFORCING BARS FIRMLY IN PLACE TO SPECIFIED COVERAGES.
9. CONTROL JOINTS SHALL BE PLACED IN A SQUARE PATTERN WITH A
MAXIMUM SPACING OF 10' - 0" O.C. FOR 4" THICK SLAB, 12' - 0" O.C. FOR 5"
THICK SLAB, 15' - 0" O.C. FOR 6" THICK SLAB. WHERE A SQUARE PATTERN
IS NOT POSSIBLE, THE MAXIMUM LONG SIDE TO SHORT SIDE OF THE
JOINT PATTERN SHALL NOT EXCEED A RATIO OF 1.5:1. CONSTRUCTION
JOINTS SHALL BE LOCATED BY THE CONTRACTOR AS REQUIRED FOR
CONSTRUCTION WITH A MAXIMUM OF 3,000 SQUARE FEET.
10. CAST DOWELS, WITH STD 90 DEGREE HOOK, IN FOOTINGS FOR
CONCRETE PIERS AND WALLS ABOVE. DOWELS SHALL BE THE SAME SIZE
AND NUMBER AS THE VERTICAL REINFORCING. (U.O.N.)
11. CONCRETE MIX DESIGNS REQUIREMENTS: - AGGREGATES SHALL
CONFORM TO ASTM C33. - CONCRETE EXPOSED TO FREEZE THAW SHALL
HAVE 4.5%-7.5% AIR. - WATER/CEMENT RATIO 0.55 MAX. FOR FOOTINGS
AND WALLS, 0.5 MAX. FOR SLABS - NO FLY ASH IN EXPOSED SLABS, 0.25
MAX. FLY ASH/CEMENT RATIO IN ALL OTHER APPLICATIONS - WATER
PROOFING ADMIXTURE ADD FOR EXTERIOR EXPOSED CONCRETE.
12 INJECTION ADHESIVE ANCHORS SHALL BE SIMPSON "SET-3G" USING
STANDARD 36 KSI THREADED RODS (U.O.N.). SEE SPECIFICATIONS FOR
USAGE. INSTALL ANCHORS IN STRUCTURAL CONFORMANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS.
CAST-IN-PLACE CONCRETE COMPRESSIVE STREGNTHS
FOOTINGS 4000 psi.
EXTERIOR FOUNDATION WALLS 4000 psi.
PIERS 4000 psi.
REINFORCING CLEAR CONCRETE COVER
CONCRETE ON SOIL 3"
SLABS ON GRADE MIDHEIGHT
FORMED WALLS & STRUCTURAL SLABS EXPOSED TO EARTH OR
WEATHER: #6 THRU #18
2"
FORMED WALLS & STRUCTURAL SLABS EXPOSED TO EARTH OR
WEATHER: #5 OR SMALLER
1 1/2"
FORMED WALLS & STRUCTURAL SLABS NOT EXPOSED TO EARTH OR
WEATHER: #11 AND SMALLER
3/4"
BEAMS AND COLUMNS (COVER TO STIRRUPS OR TIES) 1 1/2"
CONC. REINFORCING BAR LAP SPLICE
SCHEDULE
BAR SIZE
f'c = 3000 psi.
f'c = 4000 psi.
f'c = 5000 psi.
CLASS
"B"
CLASS
"B"
CLASS
"B"
#3 22" 20" 18"
#4 30" 26" 22"
#5 36" 32" 28"
#6 44" 38" 34"
#7 64" 54" 50"
#8 72" 62" 56"
#9 82" 70" 64"
#10 92" 80" 70"
#11 102" 88" 78"
BAR LAP SCHEDULE NOTES:
A. REINFORCING BAR LAP SPLICE SCHEDULE APPLIES TO UNCOATED, GRADE 60
REINFORCING BAR NORMAL WEIGHT CONCRETE.
B. PROVIDE CLASS "B" LAP UNLESS OTHERWISE NOTED.
C. FOR EPOXY COATED BAR, MULTIPLY THE NOTED LENGTHS BY 1.5.
D. FOR LIGHT WEIGHT CONCRETE, MULTIPLY THE NOTED LENGTHS BY 1.3.
E. MAXIMUM SPACING OF BARS BEING LAPPED IS ONE FIFTH THE LAP SPLICE
LENGTH, NOT TO EXCEED 6".
F. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OF FRESH CONCRETE
PLACED BELOW HORIZONTAL REINFORCEMENT.FOR TOP BARS, MULTIPLY THE
NOTED LENGTHS BY 1.3.
16. DESIGN LOADS:
LATERAL LOADS
(WIND - MSFRS)
IMPORTANCE FACTOR 1.0 Iw
ULTIMATE WIND SPEED (3 SECOND GUST) 102 MPH.
NOMINAL WIND SPEED 79 MPH.
RISK CATEGORY I
WIND EXPOSURE "C"
INTERNAL PRESSURE COEFF +/- 0.18
LATERAL LOADS
(SEISMIC - MSFRS)
RISK CATEGORY I
SEISMIC IMPORTANCE FACTOR Ie = 1
MAPPED SPECTRAL RESPONSE Ss =0.053
MAPPED SPECTRAL RESPONSE S1 = 0.035
DESIGN SPECTRAL RESPONSE Sds = 0.052
DESIGN SPECTRAL RESPONSE Sd1 = 0.054
SITE CLASS D
SEISMIC DESIGN CATEGORY A
SEISMIC FORCE RESISTING SYSTEM RIGID NON-BUILDING
STRUCTURE
DESIGN BASE SHEAR V = 0.0156W
SEISMIC RESPONCE COEFFICIENT Cs = 0.0156
RESPONSE MODIFICATION FACTOR N/A
ANALYSIS PROCEDURE RIGID NON-BUILDING
STRUCTURE
ABBREVIATIONS & SYMBOLS:
+/- PLUS OR MINUS
@ AT
A.B. ANCHOR BOLT
A.P.A. AMERICAN PLYWOOD
ASSOCIATION
A.S.T.M. AMERICAN SOCIETY OF TESTING
MATERIALS
ARCH. ARCHITECTURAL
B.B. BOND BEAM
B.O. BOTTOM OF
BLK. BLOCK
BM. BEAM
BOT. BOTTOM
BRG. BEARING
C CHANNEL
C.M.U. CONCRETE MASONRY UNIT
CCJ CONSTRUCTION CONTROL JOINT
CJ CONTROL JOINT
CL. CENTER LINE
CLR. CLEAR
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONT. CONTINUOUS
D.L. DEAD LOAD
D.T. DOUBLE TEE / DRAIN TILE
DBL. DOUBLE
DIA. DIAMETER
DIM. DIMENSION
DWL. DOWEL
E.F. EACH FACE
E.J. EXPANSION JOINT
E.W. EACH WAY
EA. EACH
EL. ELEVATION
ELEV. ELEVATOR
EQ. EQUAL
EX. EXISTING
EXC. EXCAVATION
EXP. EXPANSION
F.D. FLOOR DRAIN
FDN. FOUNDATION
FT. FEET
FTG. FOOTING
G.C. GENERAL CONTRACTOR
G.T. GIRDER TRUSS
GA. GAUGE
GALV. GALVANIZE
HC. HOLLOWCORE
HORIZ. HORIZONTAL
HSS HOLLOW STRUCTURAL SECTION
I.F. INSIDE FACE
INT. INTERIOR
JST. JOIST
KLF. KIPS PER LINEAR FOOT
KSI. KIPS PER SQUARE INCH
L ANGLE
LB LEDGER BEAM
LL LIVE LOAD / DOUBLE ANGLE
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
LWC LIGHT WEIGHT CONCRETE
M.C. MECHANICAL CONTRACTOR
MAS. MASONRY
MAX. MAXIMUM
MECH. MECHANICAL
MFG. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
MTL. METAL
N. NORTH
N.T.S. NOT TO SCALE
NS. NON-SHRINK
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F. OUTSIDE FACE
O.H. OVERHEAD
OPNG. OPENING
ORIG. ORIGINAL
P.A.F. POWDER ACTUATED FASTENER
P.C. PRECAST CONCRETE
PART. PARTITION
PL. PLATE
PLF POUNDS PER LINEAR FOOT
PNL. PANEL
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PW PLYWOOD
R. OR
RAD.
RADIUS
R.D. ROOF DRAIN
REINF. REINFORCING
REQD. REQUIRED
S.A. STUD ANCHOR
S.B. SOIL BORING
S.D. SEE DETAIL
S.D.L. SUPERIMPOSED DEAD LOAD
S.E.R. STRUCTURAL ENGINEER OF
RECORD
S.L. SNOW LOAD
S.L.L. SUPERIMPOSED LIVE LOAD
S.S. STAINLESS STEEL
SCHED. SCHEDULE
SHT. SHEET
SIM. SIMILAR
SPA. SPACING / SPACES
SPECS. SPECIFICATIONS
SQ. SQUARE
STD. STANDARD
STL. STEEL
T & B TOP & BOTTOM
T & G TONGUE & GROOVE
T.O. TOP OF
T.O.B. TOP OF BEAM
T.O.J. TOP OF JOIST
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
T.S.E. TOP OF STEEL ELEVATION
TEMP. TEMPORARY
THK. THICK / THICKENED
TRANS. TRANSVERSE
TYP. TYPICAL
U.O.N. UNLESS OTHERWISE NOTED
V. / VER. VERIFY
VERT. VERTICAL
W.L. WIND LOAD
W/ WITH
W/O WITH OUT
WD. WOOD
WTS. WEIGHTS
WWF WELDED WIRE FABRIC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18511
2026.1.14
BID DOCUMENTS
1.14.2026
C U s e rs \d w e n tl a n d
\D o c u m e n ts
\1
C O
L U
M B
A R
IU
M
S
R
V T d w e n tl a n d
G T
X
W .r v t
/1
/2
:5
:2
A
M
NOTE SHEET
JANUARY/14/2026 EW DW
S-001
7601 34TH AVE S, MINNEAPOLIS, MN, 55450
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
894CM3044
PRE-CAST CONCRETE COLUMBARIUM UNITS - DELEGATED DESIGN REQUIREMENTS:
1. THE CONTRACTOR SHALL PROVIDE STRUCTURAL DESIGN OF THE PRE-CAST CONCRETE
COLUMBARIUM UNITS. STRUCTURAL DESIGN SHALL BE SUBMITTED BY THE CONTRACTOR TO
THE CONTRACTING OFFICER'S REPRESENTATIVE (COR) AND ENGINEER OF RECORD (EOR) AS A
DELEGATED DESIGN SUBMITTAL. DELEGATED SUBMITTALS SHALL INCLUDE DRAWINGS AND
CALCULATIONS STAMPED AND SIGNED BY AN ENGINEER APPROPRIATELY LICENSED IN THE
STATE OF CONSTRUCTION.
2. THE PURPOSE OF THE EOR'S REVIEW SHALL BE IN DETERMINING THE DRAWINGS AND
CALCULATIONS HAVE BEEN PROPERLY SEALED, THAT THE LOAD CRITERIA IS IN GENERAL
CONFORMANCE WITH THE CONTRACT DOCUMENTS AND THE REFERENCED BUILDING CODE(S),
AND THAT CONNECTIONS TO THE PRIMARY STRUCTURE COMPLY WITH THE STRUCTURE'S
DESIGNED CAPABILITIES.
INCLUDED IN THE STRUCTURAL CALCULATIONS AND DESIGN, AT MINIMUM, SHALL BE:
A. DESIGN OF PRE-CAST CONCRETE COLUMBARIUM UNITS.
B. CONNECTION OF PRE-CAST UNITS TO STRUCTURAL FOUNDATIONS, BOTTOM AND TOP.
C. CONNECTION OF PRE-CAST UNITS, BACK TO BACK AND END TO END.
D. CONNECTION OF PRE-CAST UNITS TO NATURAL STONE CAPS.
3. REFER TO SPECIFICATION 03 48 24 - PRE-CAST CONCRETE COLUMBARIUM UNITS.
4. THE STRUCTURAL ENGINEER WILL RELY ON THE SPECIALTY ENGINEER'S SEAL AS
CERTIFICATION THAT THE ITEMS DESIGNED BY THE SPECIALTY ENGINEER COMPLY WITH THE
CRITERIA SET FORTH IN THE CONTRACT DOCUMENTS AND APPLICABLE CODES AND
STANDARDS. THE STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE ADEQUACY
OF DESIGNS PROVIDED BY OTHERS.
DEFERRED SUBMITTAL SCHEDULE:
PRECAST COLUMBARIUM NICHES & CONNECTIONS
Revisions: Date: 45 OF 57
A
B
C
D
E
1 2 3 4 5 6 7 8 9
24' - 5 5/8" 17' - 2 1/8" 8' - 2" 8' - 1 7/8" 25' - 4" 8' - 2" 8' - 1 7/8" 41' - 7 3/4"
F
P1 P1 P1 P1 P1 P1
P1P1
P1P1
P1P1
FC6
FC6
FC6
FC6
FC6
S-301
P1
P1
FC6
P1
P1 P1
FC6
P1 P1
FC6
P1 P1
FC6
P1 P1
FC6
+ SHEET NOTES
T.O.F.=SEE LA
T.S.W.=SEE LA
T.M.L.=SEE LAT.O.W.=SEE LA
P1
FC6
FC6
3'
6"
13' - 2" 13' - 2" 12' - 2" 12' - 2" 15' - 2" 15' - 2"
13' - 2" 13' - 2"
15' - 2" 15' - 2"
15' - 2"15' - 2"
15' - 2"15' - 2"
15' - 2"15' - 2"12' - 2" 12' - 2"
12' - 2"12' - 2"
13' - 2"
8" 8" 8"
8" 8"
8"
8" 8"
8" 8"
8" 8"
8" 8"
8" 8"
8" 8"
8" 8"
8" 8"
8" 8"
CJCJ
CJCJ
CJCJ
CJCJ
CJCJ
CJCJCJCJ
CJCJ
CJCJ
CJ
CJCJ
North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18511
2026.1.14
BID DOCUMENTS
1.14.2026
C U s e rs \d w e n tl a n d
\D o c u m e n ts
\1
C O
L U
M B
A R
IU
M
S
R
V T d w e n tl a n d
G T
X
W .r v t
/1
/2
:5
:2
A
M
FOOTING & FOUNDATION PLAN
JANUARY/14/2026 EW DW
S-101
7601 34TH AVE S, MINNEAPOLIS, MN, 55450
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
894CM3044
1. VERIFY ALL DIMENSIONS WITH LANDSCAPE ARCHITECTURAL DRAWINGS.
2. SEE SHEET S001 FOR GENERAL STRUCTURAL NOTES.
3. P# = PIER MARK - SEE PIER SCHEDULE ON THIS SHEET.
4. FC/S/T# = FOOTING MARK - SEE FOOTING SCHEDULE ON THIS SHEET.
5. TOP OF FOOTING ELEVATION IS INDICATED AS 5'-0" BELOW THE TOP OF
MASONRY LEDGE. SEE LA DRAWINGS FOR CONFIRMATION OF FINAL
ELEVATIONS. THE MINIMUM TOP OF FOOTING ELEVATION SHALL BE 5'-0"
BELOW FINISHED GRADE. NOTIFY ENGINEER IMMEDIATELY IF SITE
CONDITIONS DO NOT ALLOW THIS REQUIREMENT TO BE MET.
6. = CONSTRUCTION JOINT LOCATION - S.D. 3/S301
SHEET NOTES:
3/16" = 1'-0"
FOOTING & FOUNDATION PLAN
T.O. EXT. FOOTING EL. = 5'-0" BELOW TML
Schedule - Footings
MARK WIDTH DEPTH
REINFORCING
TRANSVERSE LONGITUDINAL
FC6 6'-0" CONT. 1'-0" #5 @ 1'-0" O.C. 8 - #5
Schedule Notes - Pier
MARK PIER SIZE COMMENTS
P1 1'-6"x5'-5" S.D. 2/S301
CJ
Revisions: Date: 46 OF 57
T.S.W.
EL. = SEE LA
STONE VENEER
SEE LA
T.O.W.
EL. = SEE LA
T.M.L.
EL. = S.D.1-S301
T.S.W.
EL. = SEE LA
EL. = S.D. 1-S301
T.O.W.
EL. = SEE LA
5" 2' - 8" 5"
3" CLR.
TYP.
SEE PLAN FOR
FOOTING
SIZE & REINF. &
ELEV.
4-ROWS #5 VERTS
@ 1'-0" O.C.
DWL. TO MATCH
@ EACH VERT.
#5 HORIZ. @ 8"
O.C. @ EA. ROW OF VERTS
3' - 6"
TYP.
1 1/2" CLR. EQ EQ EQ
VARIES
SEE LA/CIVIL
GRID
STONE CAP - SEE LA
PRECAST NICHE
UNIT - SEE LA
STAINLESS STEEL
ANCHORAGE BY
PC SUPPLIER
1/2" JOINT
STAINLESS STEEL ANCHORS
INTO NICHE UNITS BY PC
SUPPLIER
M
IN
/8
DWL. TO MATCH
@ EA. VERT.
SEE PLAN FOR
FOOTING SIZE,
REINF. & ELEV.
STONE VENEER
SEE LA
3" CLR. TYP.
TYP.
1 1/2" CLR.
VARIES
SEE LA/CIVIL
3 - #3 TIES
@ 3" O.C.
SIZE & REINF.
SEE PLAN FOR
GRID
MARK P1
RUN FDN. WALL
REINF. THRU PIER
TYP.
14 - #6 VERTS W/ #3
TIES @ 1'-0" O.C. U.O.N.
1' - 6"
5" 8" 5"
GRID
5" 2'
8"
5"
5'
5"
5" 4'
7"
5"
GRID STONE CAP - SEE LA
TYP.
1 1/2" CLR.
T.M.L.
1/2" DIA. x 6" HAS-R 316
STAINLESS STEEL
THREADED ROD W/ HILTI
HIT-HY 200 ADHESIVE 4
PER CAP
M
IN
NOTE:
1. NOTIFY LANDSCAPE ARCHITECT IF JOINTS EXCEED CRITERIA
BELOW.
2. JOINT MAXIMUM SPACING = 20'-0" FOR WALLS 3'-0" OR GREATER.
3. JOINT MAXIMUM SPACING = 30'-0" FOR WALLS 2'-0" - 3'-0"
4. JOINT MAXIMUM SPACING = 45'-0" FOR WALLS 2'-0" AND SMALLER
1"
1/2"
S
IZ
E
R E
IN
F
S E
E P
LA
N
F O
R
1 1/2"
6" 6"
SEE SCHED.
LAP SPLICE3" CLR.VERT. CAULK JOIST @
EACH FACE
2" x 6" x 6" LONG. VERT. KEYWAY (2" x 4" x 6" @ 8" WALL) EVENLY
SPACED BETWEEN HORIZ. REINF.
SPACING. KEYWAY CONT. WHERE
WATERSTOP IS REQUIRED
VERT. CAULK
VERT. ROD STOCK
WATERSTOP
WHERE
REQUIRED
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18511
2026.1.14
BID DOCUMENTS
1.14.2026
C U s e rs \d w e n tl a n d
\D o c u m e n ts
\1
C O
L U
M B
A R
IU
M
S
R
V T d w e n tl a n d
G T
X
W .r v t
/1
/2
:5
:2
A
M
FOOTING & FOUNDATION DETAILS
JANUARY/14/2026 EW DW
S-301
7601 34TH AVE S, MINNEAPOLIS, MN, 55450
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
894CM3044
1/2" = 1'-0"S-301
1 FOUNDATION WALL DETAIL
1/2" = 1'-0"S-301
2 EXTERIOR PIER DETAIL
1/2" = 1'-0"S-301
3 WALL CONSTRUCTION JOINT DETAIL
Revisions: Date: 47 OF 57
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
3"
4"
4"
SECTIO
N 19
SECTION 38
IR102 / IR104
IR103 / IR105
SORENSEON DRIVE
PEC
K AVE
PRUDEN DRIVE
KR
AU
S D R
IVE
M
AIN
LI
NE A
ND W
IR
E P
ATH
S A
PPROXIM
ATE
LY
' F
ROM
C
OLU
M
BARIA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18511Date:
Office of Design and Construction
Services
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
894CM3044
JANUARY 12, 2026
7601 34TH AVE S, MINNEAPOLIS, MN, 55450
CONSTRUCTION
DOCUMENTSIRRIGATION:
WATER IN MOTION
175 JAMES AVE N,
MINNEAPOLIS, MN, 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
COST ESTIMATOR:
TOTAL COST MANAGEMENT
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
GEOTECHNICAL ENGINEER:
TERRACON
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
KEY MAP
N.T.S.
2026.01.14
ADDENDUM ONE 2026.03.27
LI100
IRRIGATION OVERALL
SCALE MUST MEASURE 1 INCH OR DRAWING IS NOT TO SCALE.
1" =
60' 0' 30' 60' 240'
60'
SHEET DESCRIPTION
IR100 IRRIGATION OVERVIEW
IR101 IRRIGATION DEMOLITION PLAN
IR102 SECTION 38 IGC IRRIGATION DEMOLITION PLAN
IR103 SECTION 19 COLUMBARIA IRRIGATION DEMOLITION PLAN
IR104 IRRIGATION OVERALL PLAN
IR105 SECTION 38 IGC IRRIGATION PLAN
IR106 SECTION 19 COLUMBARIA IRRIGATION PLAN
IR200 IRRIGATION DATA
IR500 IRRIGATION DETAILS
SHEET_INDEX
GENERAL DIRECTION
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
894CM3044
7601 34TH AVE S, MINNEAPOLIS, MN, 55450
CONSTRUCTION
DOCUMENTS
(FONT CHANGED TO ARIAL)
2026.03.31 48 OF 57
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
3"
4"
4"
SECTIO
N 19
SECTION 38
IR102 / IR104
IR103 / IR105
SORENSEON DRIVE
PEC
K AVE
PRUDEN DRIVE
KR
AU
S D R
IVE
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
EXISTING IRRIGATION LATERAL TO BE REMOVED. REMOVE
PIPE AND RETURN EQUIPMENT TO CLIENT.
EXISTING IRRIGATION MAINLINE TO BE REMOVED. REMOVE
PIPE AND RETURN EQUIPMENT TO CLIENT.
EXISTING IRRIGATION LATERAL TO BE PROTECTED.
EXISTING IRRIGATION MAINLINE TO BE PROTECTED.
EXISTING IRRIGATION CONTROLLER AND WIRES TO BE
PROTECTED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18511Date:
Office of Design and Construction
Services
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
894CM3044
JANUARY 12, 2026
7601 34TH AVE S, MINNEAPOLIS, MN, 55450
CONSTRUCTION
DOCUMENTSIRRIGATION:
WATER IN MOTION
175 JAMES AVE N,
MINNEAPOLIS, MN, 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
COST ESTIMATOR:
TOTAL COST MANAGEMENT
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
GEOTECHNICAL ENGINEER:
TERRACON
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
KEY MAP
N.T.S.
2026.01.14
ADDENDUM ONE 2026.03.27
LI101
IRRIGATION DEMOLITION PLAN
SCALE MUST MEASURE 1 INCH OR DRAWING IS NOT TO SCALE.
1" =
60' 0' 30' 60' 240'
60'
2026.03.31 49 OF 57
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
EXISTING IRRIGATION LATERAL TO BE REMOVED. REMOVE
PIPE AND RETURN EQUIPMENT TO CLIENT.
EXISTING IRRIGATION MAINLINE TO BE REMOVED. REMOVE
PIPE AND RETURN EQUIPMENT TO CLIENT.
EXISTING IRRIGATION LATERAL TO BE PROTECTED.
EXISTING IRRIGATION MAINLINE TO BE PROTECTED.
EXISTING IRRIGATION CONTROLLER AND WIRES TO BE
PROTECTED.
3"
4"
SECTION 38
SORENSEON DRIVE
EXISTING MAINLINE TO BE USED.
EXISTING MAINLINE
TO BE USED.
EXISTING MAINLINE
TO BE USED.
EXISTING WIRE PATH TO BE USED.
NEW STATIONS SHALL FOLLOW
AND USE EXISTING WIRE PATH.
PEDESTAL SATELLITE
CONTROLLER 7 . CONNECT SIX
NEW IRRIGATION CONTROL VALVE
WIRES AND COMMON WIRE TO THIS
SATELLITE. REFER TO WIRE
COLOR ROTATION CHART. OBTAIN
ZONE DESIGNATION AND
SEQUENCING GUIDANCE FROM
CEMETERY STAFF.
LOCATE AND PROTECT PEDESTAL
SATELLITE CONTROLLER 115VOLT
POWER SUPPLY WIRES AND ALL
IRRIGATION SIGNAL WIRES AND
COMMON WIRES.
EXISTING IRRIGATION STATION TO
REMAIN IN SERVICE.
EXISTING IRRIGATION STATION TO
REMAIN IN SERVICE.
EXISTING IRRIGATION STATION TO
REMAIN IN SERVICE.
EXISTING IRRIGATION STATIONS
TO REMAIN IN SERVICE.
EXISTING IRRIGATION
STATIONS TO REMAIN
IN SERVICE.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18511Date:
Office of Design and Construction
Services
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
894CM3044
JANUARY 12, 2026
7601 34TH AVE S, MINNEAPOLIS, MN, 55450
CONSTRUCTION
DOCUMENTSIRRIGATION:
WATER IN MOTION
175 JAMES AVE N,
MINNEAPOLIS, MN, 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
COST ESTIMATOR:
TOTAL COST MANAGEMENT
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
GEOTECHNICAL ENGINEER:
TERRACON
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
KEY MAP
N.T.S.
2026.01.14
ADDENDUM ONE 2026.03.27
LI102
SECTION 38 IGC IRRIGATION
DEMOLITION PLAN
SCALE MUST MEASURE 1 INCH OR DRAWING IS NOT TO SCALE.
1" =
20' 0' 10' 20' 40'
20'
2026.03.31 50 OF 57
APPROXIMATE LOCATION OF
8-INCH AND 10-INCH PRESSURE
PRESSURE MAINLINE TEE
INTERSECTION. NORTH EAST
INTERSECTION OF PRUDEN DRIVE
AND KRAUS AVE.
SECTIO
N 19
APPROXIMATE LOCATION OF TWO
PEDESTAL SATELLITE
CONTROLLERS, LOW VOLTAGE
WIRES AND 115 VOLT POWER
WIRES TO BE RELOCATED
NORTHWARD ALONG THE WEST
SIDE OF KRAUS DR
APPROXIMATELY 300 FEET TO A
LOCATION OUTSIDE THE LIMITS OF
CONSTRUCTION TO BE APPROVED
BY COR.
REMOVED AND RETROUTED. BEGINNING AT THE NW CORNER OF OLSON DR &
KRAUS DR AND CONTINUING ALONG THE NORTH SIDE OF OLSON DR WESTWARD
APPROXIMATELY 275 FEET TO A LOCATION OUTSIDE THE LIMITS OF
CONSTRUCTION AND WEST OF THE EXISTING FLOWER WATERING STATION.
APPROXIMATE LOCATION OF 3" PRESSURE MAINLINE TO BE REMOVED BEGINNING
AT THE NW CORNER OF OLSON DR & KRAUS DR AND CONTINUING ALONG THE
WEST SIDE OF KRAUS DR NORTHWARD APPROXIMATELY 300 FEET TO A LOCATION
OUTSIDE THE LIMITS OF CONSTRUCTION TO BE APPROVED BY COR.
APPROXIMATE LOCATION CONTROLLERS
9 & 10 TO BE RELOCATED
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
EXISTING IRRIGATION LATERAL TO BE REMOVED. REMOVE
PIPE AND RETURN EQUIPMENT TO CLIENT.
EXISTING IRRIGATION MAINLINE TO BE REMOVED. REMOVE
PIPE AND RETURN EQUIPMENT TO CLIENT.
EXISTING IRRIGATION LATERAL TO BE PROTECTED.
EXISTING IRRIGATION MAINLINE TO BE PROTECTED.
EXISTING IRRIGATION CONTROLLER AND WIRES TO BE
PROTECTED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18511Date:
Office of Design and Construction
Services
FORT SNELLING NATIONAL
CEMETERY GRAVESITE EXPANSION
894CM3044
JANUARY 12, 2026
7601 34TH AVE S, MINNEAPOLIS, MN, 55450
CONSTRUCTION
DOCUMENTSIRRIGATION:
WATER IN MOTION
175 JAMES AVE N,
MINNEAPOLIS, MN, 55405
763.559.1010
TIMOTHY MALOOLY, CID, CIC,
CLIA
COST ESTIMATOR:
TOTAL COST MANAGEMENT
13602 DULUTH DRIVE,
APPLE VALLEY, MN, 55124
651.587.9286
BRYAN BERTRAND
GEOTECHNICAL ENGINEER:
TERRACON
13400 15TH AVE N,
PLYMOUTH, MN, 55441
763.489.3100
DAN MAHRT, PE
BID DOCUMENTS
KEY MAP
N.T.S.
2026.01.14
ADDENDUM ONE 2026.03.27
LI103
SECTION 19 COLUMBARIA
IRRIGATION DEMOLITION PLAN
SCALE MUST MEASURE 1 INCH OR DRAWING IS NOT TO SCALE.
1" =
20' 0' 10' 20' 40'
2026.03.31 51 OF 57
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
V W
IR
E P
ATH
3"
4"
4"
SECTIO
N 19
SECTION 38
IR102 / IR104
IR103 / IR105
SORENSEON DRIVE
PEC
K AVE
PRUDEN DRIVE
KR
AU
S D R
IVE
SYMBOL MANUFACTURER/MODEL/DESCRIPTION EST QTY PSI GPM RADIUS DETAIL
TORO 640-02 41
TURF ROTOR, 2-3/8" POP-UP. NOZZLE SIZE AS NOTED ON
PLANS. STAINLESS STEEL-ENCASED NOZZLE. COMMERCIAL
APPLICATIONS. 1" INLET, NPT THREADED. WITH
CHECK-O-MATIC CHECK VALVE, AND ADJUSTABLE ARC
TRAJECTORY.
34 60 7.3 52' 3/IR500
TORO T5CKSS-RS 4.0
TURF ROTOR, 5" POP-UP, STANDARD NOZZLES, STAINLESS
STEEL RISER. ADJUSTABLE ARC PATTERNS 40-360, 25`-50`
RADIUS. WITH CHECK VALVE.
17 45 4.1 38' 2/IR500
SYMBOL MANUFACTURER/MODEL/DESCRIPTION EST QTY DETAIL
TORO P220-26-08 ANGLE 2"
ELECTRIC, 1", 1-1/2", 2" AND 3" PLASTIC IN-LINE / ANGLE
REMOTE CONTROL VALVE WITH FLOW CONTROL AND
PRESSURE REGULATION. EQUIPPED TO WITHSTAND
PRESSURE UP TO 220 PSI. FILTER SCREEN ON 2" AND 3"
MODELS. STANDARD SOLENOID.
6 1/IR500
TORO 100-SLSC 1"
ONE-PIECE, 1" SINGLE LUG QUICK COUPLER VALVE WITH
STANDARD METAL COVER.
1 10/IR500
LEEMCO LVM…