Duct Work AS_BUILTS reference drawings.pdf
PDF 10 MB Posted
- Attached to
- Y1DA--503-25-107 Renovate for Prosthetics Lab design build | NCO 4 Construction West (VA-25-00072814)
- Solicitation number
- 36C24425R0090
About this file
These are mechanical ductwork record documents for Building 1 through Building 32 at the James E. Van Zandt Veterans Administration Medical Center in Bel Air, Maryland. The detailed HVAC drawings, dated 29 June 2022, outline comprehensive duct cleaning and fire damper testing requirements across multiple buildings and floors. Key specifications include:
The project involves cleaning all existing supply, return, exhaust, and outside air ductwork, with contractors required to test all fire and smoke dampers, create final reporting documentation, and identify any access door damages. Work is to be performed with strict occupancy considerations, with specific time restrictions for different buildings and floors (e.g., work in Building 1's pharmacy areas limited to 3:00 PM to 10:00 PM, Monday through Friday). Electrical safety protocols mandate de-energizing fire/smoke dampers, implementing lockout/tagout procedures, and shutting down equipment prior to cleaning and testing. The documents provide detailed mechanical legends, floor plans, and notes for Buildings 1-32, with specific scoping for each building's unique HVAC infrastructure.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. THE MECHANICAL CONTRACT DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO INDICATE SCOPE AND THE GENERAL ARRANGEMENT OF THE SYSTEMS. WHERE APPLICABLE THE FOLLOWING NOTES SHALL APPLY TO ALL MECHANICAL
SYSTEMS.
2. THE CONTRACTOR SHALL FULLY COORDINATE THE MECHANICAL WORK WITHIN ITSELF AND WITH THE WORK OF ALL
OTHER TRADES TO PROVIDE COMPLETE AND OPERABLE SYSTEMS WITHOUT INTERFERENCES.
3. PROVIDE APPROVED FIRE STOPPING MATERIAL AROUND ALL DUCTWORK PENETRATIONS (NEW AND EXISTING) THROUGH FIRE RATED FLOORS AND WALLS. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FLOORS AND FIRE
RATED WALLS AND FIRE/SMOKE DAMPERS AT ALL PENETRATIONS THROUGH SHAFT ENCLOSURES.
4. PROVIDE ACCESS PANELS WHERE REQUIRED FOR ADEQUATE ACCESS TO ALL CONCEALED EQUIPMENT, DAMPERS AND
CONTROLS.
5. ALL DUCT SIZES REFER TO INTERNAL FREE AREA. REFER TO DRAWINGS AND SPECIFICATIONS FOR INTERNAL INSULATION
AND SOUND LINING PRIOR TO FABRICATION.
6. ALL DUCTWORK SHALL BE CONSTRUCTED OF RIGID SHEET METAL UNLESS OTHERWISE NOTED.
7. PATCH AND SEAL ALL REMAINING OPENINGS (NEW AND EXISTING) THROUGH FLOORS, CEILINGS, AND WALLS RESULTING FROM DEMOLITION OR NEW WORK WITH MATERIALS AND FINISHES TO MATCH EXISTING CONSTRUCTION AND FIRE
RATING.
8. AS AN INTEGRAL PART OF THESE DOCUMENTS, THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
9. CONTRACTOR SHALL USE CARE WHEN PERFORMING SELECTIVE DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO BUILDING FINISHES, EQUIPMENT, FURNITURE, STRUCTURE, AND MECHANICAL/ELECTRICAL SYSTEMS AND EQUIPMENT. SHOULD ANY DAMAGE OCCUR THE CONTRACTOR SHALL RESTORE DAMAGED AREA/ITEMS TO ORIGINAL
CONDITION TO MEET THE OWNER'S SATISFACTION.
10. CONTRACTOR SHALL NOTIFY AND COORDINATE WITH THE OWNER ANY UTILITY OUTAGES. OWNER SHALL BE GIVEN A
MINIMUM OF 1 WEEKS NOTICE FOR ANY OUTAGES.
11. HVAC SHALL BE MAINTAINED TO ALL AREAS OUTSIDE OF THE CURRENT PHASE OF THE RENOVATED AREA AT ALL TIMES.
PROVIDE TEMPORARY CONNECTIONS AS REQUIRED TO COORDINATE OUTAGES WITH THE OWNER A MINIMUM OF 1 WEEK
IN ADVANCE.
12. DEMOLITION AND NEW WORK THAT WILL RESULT IN DOWN TIME OF SERVICES (HVAC, PLUMBING, ELECTRICAL, ETC.)
SHALL BE PERFORMED AT PREMIUM TIME AS REQUIRED TO MINIMIZE DOWN TIME TO ADJACENT SPACES. COORDINATE
ALL OUTAGES WITH OWNER.
13. SCHEDULE ALL WORK IN OCCUPIED SPACES WITH OWNER AT LEAST TWO (2) WEEKS PRIOR TO CONSTRUCTION.
14. CONTRACTOR SHALL REMOVE, REINSTALL AND/OR RELOCATE ANY EXISTING CONDUIT, PIPING SYSTEMS, DUCTWORK, TELECOMMUNICATIONS WIRING, HANGERS/SUPPORTS, ETC. AS REQUIRED TO ACCOMPLISH THE MECHANICAL WORK
INDICATED.
15. REFER TO SPECIFICATIONS FOR DUCT CLEANING AND FIRE / SMOKE DAMPER TESTING REQUIREMENTS.
16. COORDINATE SMOKE DAMPER TESTING WITH EXISTING FIRE ALARM SYSTEM.
MECHANICAL GENERAL NOTES MECHANICAL LEGEND
AD
F/SD
FD
MOD
12x20
D
R
OED
Ø
CHANGE IN DUCT ELEVATION
(R-RISE, D-DROP)
EXHAUST DUCT UP
(DASHED LINES FOR DOWN)
RETURN DUCT UP
(DASHED LINES FOR DOWN)
SUPPLY AIR & OUTSIDE AIR DUCT UP
(DASHED LINES FOR DOWN)
COMBINATION FIRE/SMOKE DAMPER WITH
SMOKE DETECTORS AND ACCESS PANEL
FLEXIBLE DUCT
DOUBLE THICKNESS TURNING VANES
EXISTING DUCTWORK
DUCTWORK TO BE REMOVED
OPEN ENDED DUCT
NEW DUCTWORK
DUCT TRANSITION ROUND TO RECTANGULAR
DUCT TRANSITION
DUCT SIZE (FIRST FIGURE IS SIDE SHOWN)
LINEAR SLOT DIFFUSER
BALANCING DAMPER
MOTOR OPERATED DAMPER
FIRE DAMPER WITH ACCESS PANEL
ACCESS DOOR
LIMIT OF DEMOLITION
CONNECT TO EXISTING
ABOVE FINISHED FLOOR AFF
AIR HANDLING UNIT AHU
AUTOMATIC TEMPERATURE CONTROLS ATC
BUILDING AUTOMATION SYSTEM BAS
BRITISH THERMAL UNIT BTU
BRITISH THERMAL UNITS PER HOUR BTUH
CAPACITY CAP
CUBIC FEET PER MINUTE CFM
CONNECT TO EXISTING CX
DIAMETER DIA
DOWN DN
DIFFERENTIAL PRESSURE SENSOR DPS
DRAWING(S) DWG
EXHAUST AIR EA
EXHAUST FAN EF
ENERGY MANAGEMENT CONTROL SYSTEM EMCS
EXTERNAL STATIC PRESSURE ESP
EXISTING TO REMAIN EX
FEET PER MINUTE FPM
FEET FT
HEIGHT H
INCH(ES) IN
LENGTH L
POUNDS LBS
MAXIMUM MAX
THOUSAND BRITISH THERMAL UNITS PER HOUR MBH
MINIMUM MIN
OUTSIDE AIR OA
OPEN END DUCT OED
POUNDS PER SQUARE INCH PSI
QUANTITY QTY
RETURN AIR RA
RETURN AIR FAN RAF
ROOF TOP UNIT RTU
REMOVE EXISTING RX
SUPPLY AIR SA
STATIC PRESSURE SP
TESTING AND BALANCING TAB
TOTAL STATIC PRESSURE TSP
TYPICAL TYP
UNLESS OTHERWISE NOTED UON
VARIABLE AIR VOLUME VAV
WIDTH W
MECHANICAL ABBREVIATIONS
· BUILDING 1
7TH FLOOR
§ ALL WORK PERTAINING TO THE 7TH FLOOR TO BE DONE BETWEEN 4:30 PM AND 6:00 AM, MONDAY THROUGH
FRIDAY.
4TH, 5TH AND 6TH FLOORS
§ ALL WORK PERTAINING TO 4TH, 5TH, 6TH FLOOR COMMUNITY LIVING CENTER AREAS TO BE DONE BETWEEN 2 PM
AND 9 PM, MONDAY THROUGH FRIDAY, PROVIDED THE OUTSIDE AIR TEMP IS REASONABLE ENOUGH TO SHUT
DOWN THE AHU'S SERVING THESE FLOORS.
3RD FLOOR
§ ALL WORK PERTAINING TO THE 3RD FLOOR TO BE DONE BETWEEN 4:30 PM AND 6:00 AM, MONDAY THROUGH
FRIDAY.
2ND FLOOR
§ ALL WORK PERTAINING TO THE 2ND FLOOR TO BE DONE BETWEEN 4:30 PM AND 6:00 AM, MONDAY THROUGH
FRIDAY.
1ST FLOOR
§ ALL WORK PERTAINING TO THE 1ST FLOOR TO BE DONE BETWEEN 4:30 PM AND 6:00 AM, MONDAY THROUGH
FRIDAY.
§ 1ST FLOOR PHARMACY AREAS (INCLUDING ROOMS 1F10, 1F10A-E, 1F44, AND 1F50) TO BE DONE BETWEEN 3:00 PM TO 10:00 PM, MONDAY THROUGH FRIDAY. NO ONE IS ALLOWED IN THE PHARMACY AREA AFTER 10PM. PHARMACY
COMPOUNDING AREA WITHIN PHARMACY WILL NOT BE CLEANED.
§ ALL WORK IN URGENT CARE CENTER AREAS ARE TO BE DONE BETWEEN 10:00 PM AND 6:00 AM, MONDAY
THROUGH FRIDAY.
BASEMENT
§ ALL WORK PERTAINING TO THE BASEMENT TO BE DONE BETWEEN 4:30 PM TO 6:00 AM, MONDAY THROUGH
FRIDAY.
§ ALL WORK PERTAINING TO BB15C PHARMACY CACHE AND BB15E PANDEMIC TO BE DONE BETWEEN 8:00 AM AND
4:30 AM, MONDAY THROUGH FRIDAY, AND WILL REQUIRE A COORDINATED ESCORT.
· BUILDING 2
§ ALL WORK TO BE DONE BETWEEN 4:30 PM TO 6:00 AM, MONDAY THROUGH FRIDAY.
· BUILDING 6
§ ALL WORK TO BE DONE BETWEEN 4:30 PM TO 6:00 AM, MONDAY THROUGH FRIDAY, AND WILL REQUIRE A
COORDINATED POLICE ESCORT.
· BUILDING 7
§ ALL WORK TO BE DONE BETWEEN 8:00 AM TO 4:30 PM, MONDAY THROUGH FRIDAY, AND WILL REQUIRE A
COORDINATED POLICE ESCORT.
· BUILDING 11 & 20
§ ALL WORK TO BE DONE BETWEEN 8:00 AM TO 4:30 PM, MONDAY THROUGH FRIDAY, AND WILL REQUIRE A
COORDINATED ESCORT.
· BUILDING 15
§ ALL WORK TO BE DONE BETWEEN 8:00 AM TO 4:30 PM, MONDAY THROUGH FRIDAY, AND WILL REQUIRE A
COORDINATED ESCORT.
· BUILDING 32
§ ALL WORK TO BE DONE BETWEEN 4:30 PM TO 6:00 AM, MONDAY THROUGH FRIDAY.
CONSTRUCTION HOURS PER BUILDING / AREA
GALV STEEL WALL SLEEVE
GALV STEEL BLADES WITH
INTERLOCKING JOINTS IN
GALV STEEL FRAME
REPLACEABLE FUSIBLE
LINK HOOK TO CINCH
DUCT
MIN 12"x12" DUCT
ACCESS PANEL
1 1/2"x1 1/2"x1/8" GALV STEEL
CONTINUOUS MOUNTING
ANGLE, BOLT TO WALL SLEEVE
WALL
FIRE STOP MATERIAL
WITH INCOMBUSTIBLE
US GYPSUM FIRE
PROOF MINERAL WOOL
"THERMOFIBER" SAFING
DUCT
STANDING "S" SLIP
(BREAKAWAY)
CONNECTION
NOTES: 1. FIRE DAMPERS TO HAVE BREAKAWAY JOINT BETWEEN COLLARS AND DUCT.
(COLLARS SHALL BE INTEGRAL WITH FIRE DAMPERS FRAME).
2. FIRE DAMPER SHALL BE U.L. LABELED.
3. GALVANIZED SLEEVE AND FRAME CONSTRUCTION SHALL BE MINIMUM 20
GA. SHOULD DUCT BE HEAVIER THAN 20 GAUGE, PROVIDE SLEEVE AND
FRAME TO MATCH DUCT CONSTRUCTION.
NO SCALE
HORIZONTAL DUCT FIRE DAMPER DETAIL1
BKM# 20069.01
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS
ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF
PENNSYLVANIA, LICENSE NUMBER ,
EXPIRATION DATE .
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTINTING ENGINEERING
6300 BLAIR HILL LANE SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
& ASSOCIATES, INC.
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
BUILDING COST CONSULTANTS
CLEAN ALL DUCTS AND
TEST DAMPERS
12/15/2020
503-19-101
200501D
AR
L:
G :\2
.0 1\
D ra w in gs \A ca d\
AS
B
U
IL
T\ M
\H
Pl ot te d
By : S ve tla na Y ur id its ki y | 5
/1 7/
:1
PM
RECORD DOCUMENTS - 29 JUNE 2022
THESE RECORD DOCUMENTS HAVE BEEN PREPARED ON THE BASIS OF INFORMATION FURNISHED
BY OTHERS. THE ARCHITECT / ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THIS OR ANY OTHER DOCUMENT AS A RESULT.
As-Builts 06/29/2022
BJB ERS H1
MECHANICAL LEGEND,
ABBREVIATIONS, GENERAL
NOTES, AND DETAILS
1G12
EX
2x
FD
SPRINKLER PIPING
RELOCATED IN LIEU
OF CABLE TRAY
1G06
EX 36x20
EX
6x
FD
AD
2B29Q
EX 12x12
EX
2x
EX
2x
RX 30x26
EX
x6
FD 1FD
EX 30x26
6A06
EX 10x6
EX 24x14
FD
AD
EX 22x85
5A15 5A15A
AD
FD
EX 16" SUPPLY RISER
RX 6"Ø
5A03
FD
AD
EX 14" SUPPLY RISER
5A07A 5A07 5A08 5A08A
AD
FD
EX 14" SUPPLY RISER
RX 6"Ø
EX 14" SUPPLY RISER
AD FDFD
RX 7"Ø
7"Ø7"Ø
EX 14" SUPPLY RISER
AD
RX 7"Ø
6A10
EX 22x8
EX
0x
FD
AD
FD
ACCESS DOOR
RELOCATED TO
SIDE OF DUCT
3C28B
3C28
3C28B
EX 24
x1
EX 24
x1
4EX
0x
EX 48x14
SUPPLY UP
EX 50x14 RETURN UP
EX 10x6
FDFD
DRAWING NOTES:
GENERAL NOTES:
1. REMOVE EXISTING PORTION OF DUCTWORK TO POINTS INDICATED.
2. EXISTING CABLE TRAY TO BE REROUTED AROUND FIRE DAMPER ACCESS.
3. REMOVE EXISTING 12x12 ACCESS DOOR IN DUCTWORK.
4. EXISTING DOWN LIGHT TO BE RELOCATED AWAY FROM EXISTING FIRE DAMPER ACCESS DOOR.
5. EXISTING CONDUITS TO BE REROUTED AROUND EXISTING FIRE DAMPER ACCESS DOOR.
6. REMOVE EXISTING FIRE DAMPER.
1. REFER TO H1 FOR MECHANICAL LEGEND, ABBREVIATIONS AND GENERAL NOTES.
BKM# 20069.01
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS
ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF
PENNSYLVANIA, LICENSE NUMBER ,
EXPIRATION DATE .
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTINTING ENGINEERING
6300 BLAIR HILL LANE SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
& ASSOCIATES, INC.
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
BUILDING COST CONSULTANTS
CLEAN ALL DUCTS AND
TEST DAMPERS
12/15/2020
503-19-101
200501D
PROJECT NORTH
TRUE NORTH
AR
L:
G :\2
.0 1\
D ra w in gs \A ca d\
AS
B
U
IL
T\ M
\1 -1
-H
Pl ot te d
By : S ve tla na Y ur id its ki y | 5
/1 7/
:5
PM
RECORD DOCUMENTS - 29 JUNE 2022
THESE RECORD DOCUMENTS HAVE BEEN PREPARED ON THE BASIS OF INFORMATION FURNISHED
BY OTHERS. THE ARCHITECT / ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THIS OR ANY OTHER DOCUMENT AS A RESULT.
As-Builts 06/29/2022
BJB ERS 1-1/2/3/5/6-H1
BUILDING 1 PART PLANS
FIRE DAMPER CORRECTIVE
ACTIONS - DEMOLITION
SCALE: 1/4" = 1'-0"1
PART FIRST FLOOR PLAN
ROOM 1G12 - DEMOLITION
SCALE: 1/4" = 1'-0"2
PART FIRST FLOOR PLAN
ROOM 1G06 - DEMOLITION
SCALE: 1/4" = 1'-0"3
PART SECOND FLOOR PLAN
ROOM 2B29Q - DEMOLITION
SCALE: 1/4" = 1'-0"4
PART THIRD FLOOR PLAN
ROOMS 3C28 & 3C28B - DEMOLITION
SCALE: 1/4" = 1'-0"7
PART FIFTH FLOOR PLAN
ROOM 5B07 & 5B08 - DEMOLITION
SCALE: 1/4" = 1'-0"6
PART FIFTH FLOOR PLAN
ROOM 5A03 - DEMOLITION
SCALE: 1/4" = 1'-0"5
PART FIFTH FLOOR PLAN
ROOM 5A15 - DEMOLITION
SCALE: 1/4" = 1'-0"8
PART SIXTH FLOOR PLAN
ROOM 6A10 - DEMOLITION
SCALE: 1/4" = 1'-0"9
PART SIXTH FLOOR PLAN
ROOM 6A06 - DEMOLITION
1G12
EX
2x
FD
22x12
AD
SPRINKLER PIPING
RELOCATED IN LIEU
OF CABLE TRAY
1G06
EX 36x20
EX
6x
FD
AD
2B29Q
EX 12x12
EX
2x
EX
2x x2
EX
x6
FD
FD
EX 30x26
8x
AD
AD
6A06
EX 24x14
FD
AD
EX 22x89
5A15 5A15A
FD
EX 16" SUPPLY RISER
AD
6"Ø
8x8
5A03
FD
AD
EX 14" SUPPLY RISER
5A07A 5A07 5A08 5A08A
FD
EX 14" SUPPLY RISER EX 14" SUPPLY RISER
AD
7"Ø 7"Ø7"Ø
EX 14" SUPPLY RISER
AD
7"Ø
FDFD
AD
6"Ø
8x8
1 1
6A10
EX 22x8
EX
0x
FD
AD
ACCESS DOOR
RELOCATED TO
SIDE OF DUCT
3C28B
3C28
3C28B
EX 24
x1
EX 24
x1
4EX
0x
EX 48x14
SUPPLY UP
EX 50x14 RETURN UP
EX 10x6
FDFD
AD AD
BKM# 20069.01
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS
ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF
PENNSYLVANIA, LICENSE NUMBER ,
EXPIRATION DATE .
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTINTING ENGINEERING
6300 BLAIR HILL LANE SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
& ASSOCIATES, INC.
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
BUILDING COST CONSULTANTS
CLEAN ALL DUCTS AND
TEST DAMPERS
12/15/2020
503-19-101
200501D
PROJECT NORTH
TRUE NORTH
AR
L:
G :\2
.0 1\
D ra w in gs \A ca d\
AS
B
U
IL
T\ M
\1 -1
-H
Pl ot te d
By : S ve tla na Y ur id its ki y | 5
/1 7/
:5
PM
RECORD DOCUMENTS - 29 JUNE 2022
THESE RECORD DOCUMENTS HAVE BEEN PREPARED ON THE BASIS OF INFORMATION FURNISHED
BY OTHERS. THE ARCHITECT / ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THIS OR ANY OTHER DOCUMENT AS A RESULT.
As-Builts 06/29/2022
BJB ERS 1-1/2/3/5/6-H2
BUILDING 1 PART PLANS
FIRE DAMPER CORRECTIVE
ACTIONS - NEW WORK
SCALE: 1/4" = 1'-0"1
PART FIRST FLOOR PLAN
ROOM 1G12 - NEW WORK
SCALE: 1/4" = 1'-0"2
PART FIRST FLOOR PLAN
ROOM 1G06 - NEW WORK
SCALE: 1/4" = 1'-0"3
PART SECOND FLOOR PLAN
ROOM 2B29Q - NEW WORK
SCALE: 1/4" = 1'-0"4
PART THIRD FLOOR PLAN
ROOMS 3C28 & 3C28B - NEW WORK
SCALE: 1/4" = 1'-0"7
PART FIFTH FLOOR PLAN
ROOM 5B07 & 5B08 - NEW WORK
SCALE: 1/4" = 1'-0"6
PART FIFTH FLOOR PLAN
ROOM 5A03 - NEW WORK
SCALE: 1/4" = 1'-0"5
PART FIFTH FLOOR PLAN
ROOM 5A15 - NEW WORK
SCALE: 1/4" = 1'-0"8
PART SIXTH FLOOR PLAN
ROOM 6A10 - NEW WORK
SCALE: 1/4" = 1'-0"9
PART SIXTH FLOOR PLAN
ROOM 6A06 - NEW WORK
DRAWING NOTES:
GENERAL NOTES:
1. TEST EXISTING FIRE DAMPER(S). SHOULD ANY DAMPER PROVE DEFECTIVE, REPLACE AS
NECESSARY.
2. PROVIDE NEW SECTION OF DUCTWORK WITH 12x12 FIRE DAMPER ACCESS DOOR IN BOTTOM OF
DUCT.
3. REROUTE CABLE TRAY AROUND FIRE DAMPER ACCESS.
4. PROVIDE NEW 18x18 ACCESS DOOR IN BOTTOM OF DUCTWORK.
5. PROVIDE NEW FIRE DAMPER IN NEW SECTION OF DUCTWORK.
6. PROVIDE TWO (2) NEW 8x8 FIRE DAMPER ACCESS DOORS IN THE SIDE OF STACKED 12x12
DUCTS EXITING SHAFT.
7. PROVIDE NEW SECTION OF DUCTWORK WITH 6x6 FIRE DAMPER ACCESS DOOR IN BOTTOM OF
DUCT.
8. RELOCATE EXISTING DOWN LIGHT AWAY FROM EXISTING FIRE DAMPER ACCESS DOOR.
9. REROUTE EXISTING CONDUITS AROUND EXISTING FIRE DAMPER ACCESS DOOR.
1. REFER TO H1 FOR MECHANICAL LEGEND, ABBREVIATIONS AND GENERAL NOTES.
2. CONTRACTOR SHALL REPAIR / REPLACE ANY INSULATION DAMAGED / REMOVED FROM DUCTWORK AND
DAMPERS AS PART THE WORK IN THE AREAS INDICATED ON THIS DRAWING.
1E17
1E20
1E21 1E23
1E22
1E18
1E15 1E05
1E16
1G14A 1A171A17A
1A02
1A04 1A10B
1A10A
WAITING
1A01
1A16
1A38 1A39 1A40
1A41
1A15
1A14
1A131A221A23 1A37B
1A36
1A31
1A35
1A34
1A33
1A32 1A25
1A24 1A21 1A11
1A26
1A271A281A291A30
STAIR
F1
1A12A
1A12
1A09D 1A09C 1A09B 1A09A 1A07
1A051E19
1A08 1A10
1A37A
1A37
1E05A
1A06
CORRIDOR
1A1
CORRIDOR
1A2
CORRIDOR
1A4
1D01
1D02
1D051D07
1D06 1D04
1D091D11
1D12 1D10
1D17 1D15
1D18 1D16
1D24 1D23
1D21
1D14
1D14A
1D20
STAIR
D1
1D26
1D27
1D19
1D281D291D25
1D30
1D32
1D33
1D35
1D31
1D34
1D36
1D39
1D37
1D13
WAITING
1B01
1B02
1B03
1B04
1B05
1B07
1B06 1B01A
1B081B08E
1B08A
1B08B
1B08C
1B09A
1B09B
1B09C
1B09H1B08D
1B09G
1B09
1B09F 1B09E 1B09D
1C28 1C29
1C04
1C07
1C09
1C11 1C25
1C23 1C22
1C19
1C12
1C14
1C26 1C24 1C21 1C20 1C18 1C17 1C16
1C15
1C13
1C10
1C08
1C06
1C05
1C03
1C02
1C01A
1C01A2
1C01A1
1C30 1C31
1D38
1D22
WAITING
1D08
1C00
1D10A
1D03
STAIR
B1
STAIR
H1
CORRIDOR
1B2
CORRIDOR
1C1
1C27
CORRIDOR
1D1
CORRIDOR
1D2
ELEV 1B10
1C01
1D27A
STAFF CORRIDOR
1D3
B108-1
B118-1
B100-1
FDFDFD FD
28x12 26x12
28x12 x1 x8 x8
10x8 x8 x1
24x14
10x10 x1
30x14 x8
12x12
10x1012x12
10x10 x1 x1
12x6 x6
6x6
4"Ø
8" Ø
26x16 24x14 x1 x6 12x6 x1
10x8 14x12 12x12
12x4
8x x1
SCALE: 1/" = 1'-0"1 PART FIRST FLOOR PLAN - HVAC
BKM# 20069.01
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS
ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF
PENNSYLVANIA, LICENSE NUMBER ,
EXPIRATION DATE .
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTINTING ENGINEERING
6300 BLAIR HILL LANE SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
& ASSOCIATES, INC.
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
BUILDING COST CONSULTANTS
CLEAN ALL DUCTS AND
TEST DAMPERS
12/15/2020
503-19-101
200501D
SCALE: 1/16" = 1'-0"
8'-0"16'-0"0 32'-0"
PROJECT NORTH
TRUE NORTH
AR
L:
G :\2
.0 1\
D ra w in gs \A ca d\
AS
B
U
IL
T\ M
\1 -1
-H
- 1
ST
F
LR
P
LN
Pl ot te d
By : S ve tla na Y ur id its ki y | 6
/2 9/
:5
PM
KEY PLAN
RECORD DOCUMENTS - 29 JUNE 2022
THESE RECORD DOCUMENTS HAVE BEEN PREPARED ON THE BASIS OF INFORMATION FURNISHED
BY OTHERS. THE ARCHITECT / ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THIS OR ANY OTHER DOCUMENT AS A RESULT.
As-Builts 06/29/2022
BKM BKM 1-1-H2
BUILDING 1 - PART
1ST FLOOR PLAN - HVAC
GENERAL NOTES:
1. ALL DUCTWORK SHOWN ON THIS FLOOR SHALL BE EXISTING TO REMAIN. DUCTWORK IS
SHOWN ONLY TO DEMONSTRATE APPROXIMATE SCOPE OF DUCT CLEANING
REQUIREMENTS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN FIELD.
2. CLEAN ALL SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR DUCTWORK IN ACCORDANCE
WITH SPECIFICATIONS.
3. ALL DIFFUSERS SHALL BE CLEANED BEFORE BEING REPLACED IN CEILING.
4. FIRE AND SMOKE DAMPERS SHOWN ON THIS PLAN SHALL NOT BE CONSIDERED TO BE A
COMPLETE INVENTORY OF ALL EXISTING DAMPERS.
5. CONTRACTOR SHALL TEST ALL FIRE AND SMOKE DAMPERS ON ALL FLOORS, WHETHER
INDICATED ON DRAWINGS OR NOT. CONTRACTOR SHALL INDICATE ANY INACCESSIBLE
DAMPERS IN THE TESTING PROCEDURE DOCUMENTATION. CONTRACTOR SHALL
CREATE A FINAL REPORT NOTING WHETHER DAMPERS WERE FOUND OR NOT.
6. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS OF EXACT LOCATIONS OF FIRE AND
SMOKE DAMPERS UPON COMPLETION OF PROJECT.
7. CONTRACTOR SHALL IDENTIFY ANY DAMAGES TO EXISTING ACCESS DOORS WHILE
SURVEYING THE FIRE DAMPERS AND INCLUDE THESE DAMAGES IN FINAL REPORT.
8. THE FACILITY WILL BE OCCUPIED AND OPERATING DURING THE DURATION OF THE
PROJECT. REFER TO SHEET H1 FOR ALLOWABLE WORK HOURS FOR EACH BUILDING.
ELECTRICAL NOTES:
1. ALL ELECTRICAL FED FIRE/SMOKE DAMPERS IN AREA OF WORK SHALL BE DE-ENERGIZED BEFORE
PERFORMING ANY CLEANING OR WORK.
2. MOTORS (EQUIPMENT) FEEDING DUCTS SHALL BE SHUTDOWN PRIOR TO CLEANING AND TESTING.
3. LOCKOUT/TAGOUT PROCEDURES SHALL BE STRICTLY ENFORCED.
4. RE-ENERGIZED DAMPERS ONCE WORK ON SECTION IS COMPLETE.
REFER TO 1-1-H1 FOR CONTINUATION
AutoCAD SHX Text F.D.
F5
2A21 2A21B 2A21A1
2A18
2A20
2A20C
2A06
2A17
2A16 2A15 2A12
2A13
2A11
2A08
2A10
2A07
2A09
STAIR
A2
2A05 2A04A
2A03B1
2A03B 2B01
2A03A
2A03C
2C03
FOOD SERVICE
KITCHEN
2A04
2A11A
2A02
2A01 2B02 2B04
2B05
2B07
STAIR
C2
2C01
2C08A1
2C09
2C10
2C16A
2C12
2C16
2C17
2C18 2C21
2C08A
2C19
2C20
2C08
2C02
2B06C
2B06B 2B06A 2B06R 2B06P 2B06O
2B08 2B09 2B10
2B06N1
2B39 2B40
2B06N
STAIR
D2
STAIR
B2
2B41 2B42
2B53 2B55 2B56
2B56A
2B52
2B542B50
2B44 2B512B432B112B06S 2B06Q
2B06J2B06G 2B06D
2B06L
2B06K2B06H2B06F2B06E
2B47
2B45 2B46 2B49
2B482B30D2
2B30D1
2B30D
2B30C
2B30B
2B29B2B29C
2B29D2B29E2B29F
2B29
2B30
2B30A
2B29A 2B29H
CHEMISTRY
2B29G
2B29I
2B29K
2B29M
2B29Q
2B29R
2B29P
2B29S 2B29O 2B29U
2B38A
2B36
2B38
2B35
2B37
2B29T2B29N
2B29L
2B29J
STAIR
E2
2B29W
2A19
2A04B
2A14
LOADING DOCK /
CORRIDOR
2A3
2A03
2C05
2C06
2C04
2C11
2C13
P6
2A17A
2A20A
2A21A
CORRIDOR
2A2
CORRIDOR
2A1
CORRIDOR
2B1
2B03
CORRIDOR
2B3
CORRIDOR
2B2
2B29V
CORRIDOR
2B4
CORRIDOR
2B5
CORRIDOR
2C1
CORRIDOR
2C3
CORRIDOR
2C2
2B06
ROOF BELOW
2A20B
P3
P2
S4
P7
ELEV.
STAIR
G2
2D01A
2D01 2D02
2D01B
2D01C
2D07
2D06 2D09 2D13A
2D13
2D13B
2D13C
CORRIDOR
2D
CORRIDOR
2D1
90 x 34
40x12 90x32 RA 24 x1
12x12
16x12 x1 x1 x1
12x814x10
8"Ø
48x30
RA UP 34
x2 x1
20x12
16x10
16x16
16x16 x1
26x1630x18 x8 x8 x8 x1 x1
14x12
16x12
12x12
32x12 x1 x1 x1
8x12
8x8
12x12
64x24
16x12 x1
32x188x x8
12x10 6x10
10x12
10"Ø
"Ø x1
10x10 x6
8x68x
8x
8x8
6" Ø
36x14 x1
10x10 8"Ø
10x10 8"Ø
10x6
8x8 x1
30x1230x8 x8
10x4
10"Ø
8" Ø
8"Ø8" Ø
18x12
12x6 6x6 x1
20x12 18x12
8x x8 x8
12x4
8" Ø x1 x1
10x4
12x6 x1
"Ø
10"Ø x1 x6
8x
8x6 x1
8x88x10 8x6 8"
Ø
8"Ø x1 x1
"Ø
8x8
6"Ø
8"Ø8"Ø
14x8
14x88x
8x
8x
90x32
12x6
12x6 12x6 8x4
8x4 x8 x8 x1
10x6
16x10
16x10 x1
20x412x6 20x4
20x4
12x10
12x10 x1 x1 x1 x8
EF
38x22 12x10 8x6 x2 x2
14x12
30x26
18x14
8x x2
EX 1-EF29A
EX 1-EF30
EX 1-GRH1
EX 1-GIH1
EX 1-EF28
EX 1-EF29
EX 1-EF-1A
EX 1-EF-1B
LOCATION
OF RTU-1A
AND RTU-1B
x1
DN TO EA
HOOD
22x10 x1
8x
14x12
10x10 x1
SCALE: 1/16" = 1'-0"1 PART SECOND FLOOR PLAN - HVAC
BKM# 20069.01
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS
ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF
PENNSYLVANIA, LICENSE NUMBER ,
EXPIRATION DATE .
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTINTING ENGINEERING
6300 BLAIR HILL LANE SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
& ASSOCIATES, INC.
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
BUILDING COST CONSULTANTS
CLEAN ALL DUCTS AND
TEST DAMPERS
12/15/2020
503-19-101
200501D
SCALE: 1/16" = 1'-0"
8'-0"16'-0"0 32'-0"
PROJECT NORTH
TRUE NORTH
AR
L:
G :\2
.0 1\
D ra w in gs \A ca d\
AS
B
U
IL
T\ M
\1 -2
-H
- 2 N
D F
LR
P
LN
Pl ot te d By
: S ve tla na
Y ur id its ki y
| 6 /2
7/
:1
AM
KEY PLAN
RECORD DOCUMENTS - 29 JUNE 2022
THESE RECORD DOCUMENTS HAVE BEEN PREPARED ON THE BASIS OF INFORMATION FURNISHED
BY OTHERS. THE ARCHITECT / ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THIS OR ANY OTHER DOCUMENT AS A RESULT.
As-Builts 06/29/2022
BKM SY 1-2-H1
BUILDING 1 - PART
2ND FLOOR PLAN - HVAC
GENERAL NOTES:
1. ALL DUCTWORK SHOWN ON THIS FLOOR SHALL BE EXISTING TO REMAIN. DUCTWORK IS
SHOWN ONLY TO DEMONSTRATE APPROXIMATE SCOPE OF DUCT CLEANING
REQUIREMENTS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN FIELD.
2. CLEAN ALL SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR DUCTWORK IN ACCORDANCE
WITH SPECIFICATIONS.
3. ALL DIFFUSERS SHALL BE CLEANED BEFORE BEING REPLACED IN CEILING.
4. FIRE AND SMOKE DAMPERS SHOWN ON THIS PLAN SHALL NOT BE CONSIDERED TO BE A
COMPLETE INVENTORY OF ALL EXISTING DAMPERS.
5. CONTRACTOR SHALL TEST ALL FIRE AND SMOKE DAMPERS ON ALL FLOORS, WHETHER
INDICATED ON DRAWINGS OR NOT. CONTRACTOR SHALL INDICATE ANY INACCESSIBLE
DAMPERS IN THE TESTING PROCEDURE DOCUMENTATION. CONTRACTOR SHALL
CREATE A FINAL REPORT NOTING WHETHER DAMPERS WERE FOUND OR NOT.
6. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS OF EXACT LOCATIONS OF FIRE AND
SMOKE DAMPERS UPON COMPLETION OF PROJECT.
7. CONTRACTOR SHALL IDENTIFY ANY DAMAGES TO EXISTING ACCESS DOORS WHILE
SURVEYING THE FIRE DAMPERS AND INCLUDE THESE DAMAGES IN FINAL REPORT.
8. THE FACILITY WILL BE OCCUPIED AND OPERATING DURING THE DURATION OF THE
PROJECT. REFER TO SHEET H1 FOR ALLOWABLE WORK HOURS FOR EACH BUILDING.
ELECTRICAL NOTES:
1. ALL ELECTRICAL FED FIRE/SMOKE DAMPERS IN AREA OF WORK SHALL BE DE-ENERGIZED BEFORE
PERFORMING ANY CLEANING OR WORK.
2. MOTORS (EQUIPMENT) FEEDING DUCTS SHALL BE SHUTDOWN PRIOR TO CLEANING AND TESTING.
3. LOCKOUT/TAGOUT PROCEDURES SHALL BE STRICTLY ENFORCED.
4. RE-ENERGIZED DAMPERS ONCE WORK ON SECTION IS COMPLETE.
DRAWING NOTES:
1. REFER TO PART PLAN 3 ON DRAWINGS 1-1/2/3/5/6-H1 & H2 FOR ADDITIONAL CORRECTIVE
ACTIONS ASSOCIATED WITH FIRE DAMPERS IN THIS AREA.
REFER TO 1-2-H2 FOR CONTINUATION
ADDITIONAL HVAC SCOPE:
1. ROOM 2B01: CAP EXISTING OPEN ENDED SUPPLY DUCTS ABOVE CEILING IN THIS
AREA (2 LOCATIONS). DUCT OPENINGS ARE ROUGHLY 24x24. CONTRACTOR TO
VERIFY EXACT SIZES.
2D03
ELEV.
STAIR
G2
2D01A
2D01 2D02
2D01B
2D01C
2D07
2D06 2D09 2D13A
2D03B 2D03A
2D03C
2D03
2D05
2D13
2D13B
2D13C
2D30
2D28
2D26
2D15
2D14
2D16
2D112D08
2D27
2D29
2D24
2D17
2D19
2D20 2D23
2D21F 2D21E 2D21C
2D21A
2D21D
2D21B 2D21
STAIR
H2
CORRIDOR
2D
CORRIDOR
2D1
8ø
32x188x x8
12x10 6x10
10x12
10"Ø
"Ø x1 x1 x1
"Ø x1
14x12 12x12 10x10 8"Ø
10x106x10
10x10 x6
8x68x
8x
8x8
6" Ø x1 x1
8" Ø
8"Ø 10x10 8"Ø
8"Ø8"Ø
8"Ø 8"Ø
36x14 x1 x1
24x12 14x12 12x10 10x6
18x8
10x10 8"Ø
10x10 8"Ø
10x6
8x8 x1
30x1230x8 x8 x8
14x8 x8
24x6 18x6
10x4
8"Ø
8x10 x8 x8
12x4
8" Ø
18x818x8
18x818x8
6"Ø
6"Ø
6" Ø
14x14 x1
8x x1
8" Ø
8x
12x12 x1
10"Ø10"Ø
10"Ø x1
30x8 18x8 x1
24x1024x8
8x x1
10x4
12x6
16x6 x6 x6 x4 x6
10x410x4 x1 x1 x1 x1
14x148"Ø
"Ø
10"Ø x1 x6
8x
8x6 x1
8x88x10 8x6 8"
Ø
8x8
8"Ø x1
8"
Ø
8x10
8" Ø
8"Ø x1 x1
"Ø
8"Ø 12x14
8x8
6"Ø
8"Ø8"Ø
6" Ø
6" Ø
10"Ø
10x10 8x8
6" Ø
6"Ø
6" Ø 6"Ø
10x10 10"Ø
6" Ø
16x16 14x12 8x12
8" Ø
12x1210x12
8" Ø 8" Ø8"
Ø x1
10x10 10x6
8x
14x8
14x8
14x6
10x14 10x10
10x10
6" Ø x6
8x4
8x4
8x4 x1 x1
8x4
8x4
8x
8x
8x
8x4
8x4
SCALE: 1/" = 1'-0"1 PART SECOND FLOOR PLAN - HVAC
BKM# 20069.01
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS
ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF
PENNSYLVANIA, LICENSE NUMBER ,
EXPIRATION DATE .
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTINTING ENGINEERING
6300 BLAIR HILL LANE SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
& ASSOCIATES, INC.
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
BUILDING COST CONSULTANTS
CLEAN ALL DUCTS AND
TEST DAMPERS
12/15/2020
503-19-101
200501D
SCALE: 1/16" = 1'-0"
8'-0"16'-0"0 32'-0"
PROJECT NORTH
TRUE NORTH
AR
L:
G :\2
.0 1\
D ra w in gs \A ca d\
AS
B
U
IL
T\ M
\1 -2
-H
- 2 N
D F
LR
P
LN
Pl ot te d By
: S ve tla na
Y ur id its ki y
| 6 /2
7/
:1
AM
KEY PLAN
RECORD DOCUMENTS - 29 JUNE 2022
THESE RECORD DOCUMENTS HAVE BEEN PREPARED ON THE BASIS OF INFORMATION FURNISHED
BY OTHERS. THE ARCHITECT / ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THIS OR ANY OTHER DOCUMENT AS A RESULT.
As-Builts 06/29/2022
BKM SY 1-2-H2
BUILDING 1 - PART
2ND FLOOR PLAN - HVAC
GENERAL NOTES:
1. ALL DUCTWORK SHOWN ON THIS FLOOR SHALL BE EXISTING TO REMAIN. DUCTWORK IS
SHOWN ONLY TO DEMONSTRATE APPROXIMATE SCOPE OF DUCT CLEANING
REQUIREMENTS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN FIELD.
2. CLEAN ALL SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR DUCTWORK IN ACCORDANCE
WITH SPECIFICATIONS.
3. ALL DIFFUSERS SHALL BE CLEANED BEFORE BEING REPLACED IN CEILING.
4. FIRE AND SMOKE DAMPERS SHOWN ON THIS PLAN SHALL NOT BE CONSIDERED TO BE A
COMPLETE INVENTORY OF ALL EXISTING DAMPERS.
5. CONTRACTOR SHALL TEST ALL FIRE AND SMOKE DAMPERS ON ALL FLOORS, WHETHER
INDICATED ON DRAWINGS OR NOT. CONTRACTOR SHALL INDICATE ANY INACCESSIBLE
DAMPERS IN THE TESTING PROCEDURE DOCUMENTATION. CONTRACTOR SHALL
CREATE A FINAL REPORT NOTING WHETHER DAMPERS WERE FOUND OR NOT.
6. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS OF EXACT LOCATIONS OF FIRE AND
SMOKE DAMPERS UPON COMPLETION OF PROJECT.
7. CONTRACTOR SHALL IDENTIFY ANY DAMAGES TO EXISTING ACCESS DOORS WHILE
SURVEYING THE FIRE DAMPERS AND INCLUDE THESE DAMAGES IN FINAL REPORT.
8. THE FACILITY WILL BE OCCUPIED AND OPERATING DURING THE DURATION OF THE
PROJECT. REFER TO SHEET H1 FOR ALLOWABLE WORK HOURS FOR EACH BUILDING.
ELECTRICAL NOTES:
1. ALL ELECTRICAL FED FIRE/SMOKE DAMPERS IN AREA OF WORK SHALL BE DE-ENERGIZED BEFORE
PERFORMING ANY CLEANING OR WORK.
2. MOTORS (EQUIPMENT) FEEDING DUCTS SHALL BE SHUTDOWN PRIOR TO CLEANING AND TESTING.
3. LOCKOUT/TAGOUT PROCEDURES SHALL BE STRICTLY ENFORCED.
4. RE-ENERGIZED DAMPERS ONCE WORK ON SECTION IS COMPLETE.
REFER TO 1-2-H1 FOR CONTINUATION
3B01
3B02
3B03
3B06 3B05
3B08 3B07
3B09 3B10
3B01A
3B01B
3B01B1
3B01C 3E03
3E01 3E01A
3E02
3E02A
3F15 3F16 3F18 3F20
3F21
3F19
3F17
3F14
3F24
3F13
3F12
3F11
3F10
3FO9
3F05
3E05
3E05D
3E04C 3E04B
3E04
3E04A
STAIR
B3
3E05C
3E05B
3E05A
3F08B
3F08A
3F08
3F01
3F02
3B09A 3B11
3B15
3B16
3B18
3B20
3B21
3B22E
3B22E1
3B19
3B17
3B14
3B13
3B12
3B22F
3B22
3B22A
3B22B 3B22C 3B22D 3B22G
3B22H
3F22
3F23
3F12A
3F25
3F11A 3F11A1
3F10A1
3F10A
3F26
3F06
3F06A 3F05A
3F07
STAIR
E3
3F04
3F04A
OR
3F03
CORRIDOR
3B1
CORRIDOR
3B2
CORRIDOR
3F1
3E01B x1
60x12 x1
24x1212x1212x8 x8 x1
8x
8x8
36x12 x1
26x6
30x12 x1
16x10 x1 x8 x8 x8
12x12 x1
54x12
30x12
8x
8x8
12x6 x8 x1 x1 x1
18x16
32x18 x1 x8
8x x1 x1
8"Ø x1
22x8 x2 x1 x1
14"Ø
SA DN
14"Ø
SA UP
FD
SD
SDSD SDSD
SD
SD
SD
SD
FD
BKM# 20069.01
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS
ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF
PENNSYLVANIA, LICENSE NUMBER ,
EXPIRATION DATE .
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTINTING ENGINEERING
6300 BLAIR HILL LANE SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
& ASSOCIATES, INC.
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
BUILDING COST CONSULTANTS
CLEAN ALL DUCTS AND
TEST DAMPERS
12/15/2020
503-19-101
200501D
PROJECT NORTH
TRUE NORTH
AR
L:
G :\2
.0 1\
D ra w in gs \A ca d\
AS
B
U
IL
T\ M
\1 -3
-H
- 3 R
D F
LR
P
LN
Pl ot te d By
: S ve tla na
Y ur id its ki y
| 6 /2
9/
:0
PM
KEY PLAN
SCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0" RECORD DOCUMENTS - 29 JUNE 2022
THESE RECORD DOCUMENTS HAVE BEEN PREPARED ON THE BASIS OF INFORMATION FURNISHED
BY OTHERS. THE ARCHITECT / ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THIS OR ANY OTHER DOCUMENT AS A RESULT.
As-Builts 06/29/2022
R
EF
ER
T
O
-3 -H
FO
R C
O N
TI
N
U A
TI
O
N
SCALE: 1/8" = 1'-0"1 PART THIRD FLOOR PLAN - HVAC
BKM SY 1-3-H1
BUILDING 1 - PART
3RD FLOOR PLAN - HVAC
GENERAL NOTES:
1. ALL DUCTWORK SHOWN ON THIS FLOOR SHALL BE EXISTING TO REMAIN. DUCTWORK IS
SHOWN ONLY TO DEMONSTRATE APPROXIMATE SCOPE OF DUCT CLEANING
REQUIREMENTS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN FIELD.
2. CLEAN ALL SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR DUCTWORK IN ACCORDANCE
WITH SPECIFICATIONS.
3. ALL DIFFUSERS SHALL BE CLEANED BEFORE BEING REPLACED IN CEILING.
4. FIRE AND SMOKE DAMPERS SHOWN ON THIS PLAN SHALL NOT BE CONSIDERED TO BE A
COMPLETE INVENTORY OF ALL EXISTING DAMPERS.
5. CONTRACTOR SHALL TEST ALL FIRE AND SMOKE DAMPERS ON ALL FLOORS, WHETHER
INDICATED ON DRAWINGS OR NOT. CONTRACTOR SHALL INDICATE ANY INACCESSIBLE
DAMPERS IN THE TESTING PROCEDURE DOCUMENTATION. CONTRACTOR SHALL
CREATE A FINAL REPORT NOTING WHETHER DAMPERS WERE FOUND OR NOT.
6. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS OF EXACT LOCATIONS OF FIRE AND
SMOKE DAMPERS UPON COMPLETION OF PROJECT.
7. CONTRACTOR SHALL IDENTIFY ANY DAMAGES TO EXISTING ACCESS DOORS WHILE
SURVEYING THE FIRE DAMPERS AND INCLUDE THESE DAMAGES IN FINAL REPORT.
8. THE FACILITY WILL BE OCCUPIED AND OPERATING DURING THE DURATION OF THE
PROJECT. REFER TO SHEET H1 FOR ALLOWABLE WORK HOURS FOR EACH BUILDING.
ELECTRICAL NOTES:
1. ALL ELECTRICAL FED FIRE/SMOKE DAMPERS IN AREA OF WORK SHALL BE DE-ENERGIZED BEFORE
PERFORMING ANY CLEANING OR WORK.
2. MOTORS (EQUIPMENT) FEEDING DUCTS SHALL BE SHUTDOWN PRIOR TO CLEANING AND TESTING.
3. LOCKOUT/TAGOUT PROCEDURES SHALL BE STRICTLY ENFORCED.
4. RE-ENERGIZED DAMPERS ONCE WORK ON SECTION IS COMPLETE.
ADDITIONAL HVAC SCOPE:
1. ROOM 3B01B: REMOVE AND REPLACE EXISTING DUCT TAPE WITH PERMANENT DUCT
CAP AT RETURN AIR DUCT OPENING ABOVE CEILING IN THIS AREA.
2. ROOM 3E03: REMOVE AND REPLACE DAMAGED PORTION OF EXISTING 8" ROUND
FLEXIBLE SUPPLY DUCTWORK ABOVE CEILING IN THIS AREA.
3. ROOM 3F06: REMOVE AND REPLACE EXISTING DUCT TAPE WITH PERMANENT DUCT CAP
AT RETURN AIR DUCT OPENINGS ABOVE CEILING IN THIS AREA (3 LOCATIONS).
REVISION 1 09/27/2021
BRIDGE
3D00
LOBBY
3D01
WAITING
3D02
3D02A 3D02B
3D07
3D08
3D06
3D11 3D10
3D09
3D27A
3D27B
3D27C 3D27D 3D27E 3D27F
3D27G
CARDIOVASCULAR
3D27
3D14
3D16
WAITING
3D21
3D22 3D23
3D28 3D29
3D31
3D32 3D253D24
WORK STATION
AREA 2
3D33
3D203D193D34
3D353D37
3D38 3D393D40
3D12
3D03 3D04 3D05
3D12A
3D12C
3D12B
3D13
3D15
3D17
3D18
3D26
3D27G1
STAIR
G3
STAIR
H3
CORRIDOR
3D1
CORRIDOR
3D2
ROOF ACCESS
x8
8x6
12x10
8x
10x10
10x10
6x
8x
8x8
8x10
12x10
8x12
8x10
8x10 12x10
16x10
10x10
8x8 8x8
8x8
16x10
24x8
10x4
8x8
24x8
10x6 x1 x1 x1 x1
32x16 x1 x1 x1 x1 x1
16x10 x6 x1 x1
38x16 x1 x1 x6
12x12
14x6
8x
18x12 x6
14x10
14x6
8x6
8x
12x10 10x10
8x106x10
12x12
10x10
8x
8x
16x12
12x10 x1 x1 x1
10x10 6x10 x1
8x x1
10x12 x1 x1 x1
28x10 26x10 20x10 x1
8x
14x10 x8 x8
8x x8
8x
6x
26x14 18x12 10x10
8x8
48x16 x1 x1 x1
30x1624x1420x12
8x x1
8x8 x8 x1
214x12 10x10 x1
416x10 x1
16x10 10x10 6x1012x10
6x10
8x
8x
8x x1
10x86x8
26x12 x1
8x8 10 x1 x1 x1
12x12
18x1214x12 8x8 x1
10x6
10x6 x1 x1
8x
8x 68x x8 x8
10x10
6x10 x1
10x6
12x10
DUCT CLEANING
ASSOCIATED WITH
THIRD FLOOR ADDITION
SHALL BE CONSIDERED
DEDUCT ALTERNATE #1
ALTERNATE NOT ACCEPTED
CLEANING NOT PERFORMED
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS
ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF
PENNSYLVANIA, LICENSE NUMBER ,
EXPIRATION DATE .
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTINTING ENGINEERING
6300 BLAIR HILL LANE SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
& ASSOCIATES, INC.
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
BUILDING COST CONSULTANTS
CLEAN ALL DUCTS AND
TEST DAMPERS
12/15/2020
503-19-101
200501D
PROJECT NORTH
TRUE NORTH
AR
L:
G :\2
.0 1\
D ra w in gs \A ca d\
AS
B
U
IL
T\ M
\1 -3
-H
- 3 R
D F
LR
P
LN
Pl ot te d By
: S ve tla na
Y ur id its ki y
| 6 /2
9/
:0
PM
KEY PLAN
SCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0" RECORD DOCUMENTS - 29 JUNE 2022
THESE RECORD DOCUMENTS HAVE BEEN PREPARED ON THE BASIS OF INFORMATION FURNISHED
BY OTHERS. THE ARCHITECT / ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THIS OR ANY OTHER DOCUMENT AS A RESULT.
As-Builts 06/29/2022
SCALE: 1/8" = 1'-0"1 PART THIRD FLOOR PLAN - HVAC
BKM SY 1-3-H3
BUILDING 1 - PART
3RD FLOOR PLAN - HVAC
R
EF
ER
T
O
-3 -H
FO
R C
O N
TI
N
U A
TI
O
N
GENERAL NOTES:
1. ALL DUCTWORK SHOWN ON THIS FLOOR SHALL BE EXISTING TO REMAIN. DUCTWORK IS
SHOWN ONLY TO DEMONSTRATE APPROXIMATE SCOPE OF DUCT CLEANING
REQUIREMENTS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN FIELD.
2. CLEAN ALL SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR DUCTWORK IN ACCORDANCE
WITH SPECIFICATIONS.
3. ALL DIFFUSERS SHALL BE CLEANED BEFORE BEING REPLACED IN CEILING.
4. FIRE AND SMOKE DAMPERS SHOWN ON THIS PLAN SHALL NOT BE CONSIDERED TO BE A
COMPLETE INVENTORY OF ALL EXISTING DAMPERS.
5. CONTRACTOR SHALL TEST ALL FIRE AND SMOKE DAMPERS ON ALL FLOORS, WHETHER
INDICATED ON DRAWINGS OR NOT. CONTRACTOR SHALL INDICATE ANY INACCESSIBLE
DAMPERS IN THE TESTING PROCEDURE DOCUMENTATION. CONTRACTOR SHALL
CREATE A FINAL REPORT NOTING WHETHER DAMPERS WERE FOUND OR NOT.
6. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS OF EXACT LOCATIONS OF FIRE AND
SMOKE DAMPERS UPON COMPLETION OF PROJECT.
7. CONTRACTOR SHALL IDENTIFY ANY DAMAGES TO EXISTING ACCESS DOORS WHILE
SURVEYING THE FIRE DAMPERS AND INCLUDE THESE DAMAGES IN FINAL REPORT.
8. THE FACILITY WILL BE OCCUPIED AND OPERATING DURING THE DURATION OF THE
PROJECT. REFER TO SHEET H1 FOR ALLOWABLE WORK HOURS FOR EACH BUILDING.
ELECTRICAL NOTES:
1. ALL ELECTRICAL FED FIRE/SMOKE DAMPERS IN AREA OF WORK SHALL BE DE-ENERGIZED BEFORE
PERFORMING ANY CLEANING OR WORK.
2. MOTORS (EQUIPMENT) FEEDING DUCTS SHALL BE SHUTDOWN PRIOR TO CLEANING AND TESTING.
3. LOCKOUT/TAGOUT PROCEDURES SHALL BE STRICTLY ENFORCED.
S4
4C01A4C01
4C03
4C02
4A064A074A084A10
4A12
4A13
4A15
4A16
4A18
4A16A 4A18A
4A22A
4A22
STAIR
A4
4A21
4A21A
4A17
4A17A 4A14 4A14A
4A11
4A11A 4A09A 4A09
4A05A
4A05 4A03A
4A03
4A03B 4B05 4B05A
4B10 4B14 4B14A
4B17 4B21A
4B21
4B24 4B26 4B24A
4B28
4B27 4B25A
4B25
4B234B22
STAIR
B4
4B20
4B184B16A4B164B134B11 4B094B06
4B04 4B03
4B02
4B01
4A02
STAIR
C4
4A19
4B08
4A20
4A04
4A01
CORRIDOR
4A1
CORRIDOR
4A2
CORRIDOR
4B1
P3
P2 x8
20x12 x8
12x6 x6
12x8 12 x6 x6
12x8
12x8 28x8 x6 x6 x6
6"Ø 6"Ø
10x6 12 x1 x1
12x10 x1 x1 x8
16x9 x9
14x7 10"Ø
28x8 32x14 28x10 x8
32x12 28x10
8"Ø 12x10 x1
16x10
8" Ø x6 x1
12x10 x1
6" Ø
6"Ø x1 x6
22x8 x8 x8
12"Ø x7
F O
6" Ø x1 x1
06" Ø x1
16x9 10x6 8x412x6 x6 x4 x4
6"Ø
6" Ø x1
10x6 x6
6"Ø 12x10 x6
10x6 x8
10x6
6"Ø12 x1
6"Ø12 x1
6"Ø 12x106" Ø 12 x1
12x8 x1
22x8 x8
22x8
18x8 12x10 x1 x6
8x4 8x
8x 48x4
8x
6" Ø
6"Ø
8x
8x4
8x
40x8 x2 x2
12x6 x6 x6
24x1018x6
8" Ø
8"Ø
8" Ø x7
F O
8"Ø 12x10
12x10
12x10 x1 x6 x612 x6
8"Ø
8"Ø
8"Ø x1 x1 x6 x6
16"Ø
10x4
12x10
12x1012x10
8" Ø
8"Ø x1
12x10
12x10 x8
16x6
16x6 8x4
8x
10x4 x6 x6 x6
18x6
18x6
14x6 10x8 x6
8" Ø x1 x1 x6 x6
8x4
8"Ø
18x6 x1 x1
10x8
14x8
12x10 14"Ø
"Ø
8"Ø 8"Ø8x4
8x
12x10 x6
8"Ø12x8 14x4
10x6
10x10
10x4
8x
8x
14x8 x6 10x4
EF
12x10
EF
x5
"Ø
8x4
8x
10"Ø UP
FD FD FD FD FD FD
FD
FD
FDFDFDFDFDFD
FD
FD
FD FD FD
2 3
BKM# 20069.01
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS
ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF
PENNSYLVANIA, LICENSE NUMBER ,
EXPIRATION DATE .
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTINTING ENGINEERING
6300 BLAIR HILL LANE SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
& ASSOCIATES, INC.
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
BUILDING COST CONSULTANTS
CLEAN ALL DUCTS AND
TEST DAMPERS
12/15/2020
503-19-101
200501D
PROJECT NORTH
TRUE NORTH
AR
L:
G :\2
.0 1\
D ra w in gs \A ca d\
AS
B
U
IL
T\ M
\1 -4
-H
- 4
TH
F
LR
P
LN
Pl ot te d
By : S ve tla na Y ur id its ki y | 6
/2 7/
:2
AM
KEY PLAN
SCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0" RECORD DOCUMENTS - 29 JUNE 2022
THESE RECORD DOCUMENTS HAVE BEEN PREPARED ON THE BASIS OF INFORMATION FURNISHED
BY OTHERS. THE ARCHITECT / ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THIS OR ANY OTHER DOCUMENT AS A RESULT.
As-Builts 06/29/2022
BKM BKM 1-4-H1
BUILDING 1
4TH FLOOR PLAN - HVAC
SCALE: 1/8" = 1'-0"1 FOURTH FLOOR PLAN - HVAC
GENERAL NOTES:
1. ALL DUCTWORK SHOWN ON THIS FLOOR SHALL BE EXISTING TO REMAIN. DUCTWORK IS
SHOWN ONLY TO DEMONSTRATE APPROXIMATE SCOPE OF DUCT CLEANING
REQUIREMENTS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN FIELD.
2. CLEAN ALL SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR DUCTWORK IN ACCORDANCE
WITH SPECIFICATIONS.
3. ALL DIFFUSERS SHALL BE CLEANED BEFORE BEING REPLACED IN CEILING.
4. FIRE AND SMOKE DAMPERS SHOWN ON THIS PLAN SHALL NOT BE CONSIDERED TO BE A
COMPLETE INVENTORY OF ALL EXISTING DAMPERS.
5. CONTRACTOR SHALL TEST ALL FIRE AND SMOKE DAMPERS ON ALL FLOORS, WHETHER
INDICATED ON DRAWINGS OR NOT. CONTRACTOR SHALL INDICATE ANY INACCESSIBLE
DAMPERS IN THE TESTING PROCEDURE DOCUMENTATION. CONTRACTOR SHALL
CREATE A FINAL REPORT NOTING WHETHER DAMPERS WERE FOUND OR NOT.
6. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS OF EXACT LOCATIONS OF FIRE AND
SMOKE DAMPERS UPON COMPLETION OF PROJECT.
7. CONTRACTOR SHALL IDENTIFY ANY DAMAGES TO EXISTING ACCESS DOORS WHILE
SURVEYING THE FIRE DAMPERS AND INCLUDE THESE DAMAGES IN FINAL REPORT.
8. THE FACILITY WILL BE OCCUPIED AND OPERATING DURING THE DURATION OF THE
PROJECT. REFER TO SHEET H1 FOR ALLOWABLE WORK HOURS FOR EACH BUILDING.
ELECTRICAL NOTES:
1. ALL ELECTRICAL FED FIRE/SMOKE DAMPERS IN AREA OF WORK SHALL BE DE-ENERGIZED BEFORE
PERFORMING ANY CLEANING OR WORK.
2. MOTORS (EQUIPMENT) FEEDING DUCTS SHALL BE SHUTDOWN PRIOR TO CLEANING AND TESTING.
3. LOCKOUT/TAGOUT PROCEDURES SHALL BE STRICTLY ENFORCED.
4. RE-ENERGIZED DAMPERS ONCE WORK ON SECTION IS COMPLETE.
ADDITIONAL HVAC SCOPE:
1. ROOM 4A14: REMOVE AND REPLACE DAMAGED PORTION OF EXISTING FLEXIBLE
EXHAUST DUCTWORK ABOVE CEILING IN THIS AREA.
2. ROOM 4A16: REMOVE AND REPLACE DAMAGED PORTION OF EXISTING FLEXIBLE
SUPPLY DUCTWORK ABOVE CEILING IN THIS AREA.
3. ROOM 4B11: REMOVE AND REPLACE DAMAGED PORTION OF EXISTING FLEXIBLE
SUPPLY DUCTWORK ABOVE CEILING IN THIS AREA. PROVIDE NECESSARY
ACCESS TO ASSOCIATED INACCESSIBLE DAMPER.
REVISION 1 09/27/2021
EXISTING AHU-4
EXISTING AHU-5
EXISTING AHU-3
64x30
30x20
30x20 EA x2 x2 x1
58x18
EXISTING AHU-2
8x6
8x6
30x32
30x32
60x2612 x8
20x10
14x12 x1 x1
14x12
40x12
60x20
60x20
46x24
48x2452x2040x1240x12
FD
FD
FD
FD
DAMPER FUNCTIONAL
NOT REPLACED
DAMPER FUNCTIONAL
NOT REPLACED
DAMPER FUNCTIONAL
NOT REPLACED
** (2) FIRE DAMPERS ASSOCIATED WITH EXHAUST SYSTEMS
WERE FOUND FAULTY AND REPLACED. LOCATIONS
UNSPECIFIED **
58x18
EF-1
x4 x1
EF-12
EF-11
22x8 UP22x8 DN
48x24
22X8 ABANDONED
DUCT
EX 30x32
EX 36x32
EX 60x26
RX 14x12
EX 14x14
FD
FD FD
FD
FD
FD
EX 30x32
EX 36x32
EX 60x26
EX 14x14
14x12
FD
FD FD
FD
FD
FD
EX
4x
FD
x1
FD
4TH FLOOR
5TH FLOOR
BKM# 20069.01
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS
ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF
PENNSYLVANIA, LICENSE NUMBER ,
EXPIRATION DATE .
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTINTING ENGINEERING
6300 BLAIR HILL LANE SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
& ASSOCIATES, INC.
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
BUILDING COST CONSULTANTS
CLEAN ALL DUCTS AND
TEST DAMPERS
12/15/2020
503-19-101
200501D
PROJECT NORTH
TRUE NORTH
AR
L:
G :\2
.0 1\
D ra w in gs \A ca d\
AS
B
U
IL
T\ M
\1 -4
-H
- 4
TH
F
LR
P
LN
Pl ot te d
By : S ve tla na Y ur id its ki y | 6
/2 7/
:2
AM
KEY PLAN
SCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0" RECORD DOCUMENTS - 29 JUNE 2022
THESE RECORD DOCUMENTS HAVE BEEN PREPARED ON THE BASIS OF INFORMATION FURNISHED
BY OTHERS. THE ARCHITECT / ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THIS OR ANY OTHER DOCUMENT AS A RESULT.
As-Builts 06/29/2022
BKM BKM 1-4-H2
BUILDING 1
4TH FLOOR PLAN - HVAC
SCALE: 1/8" = 1'-0"1 FOURTH FLOOR PLAN - MECHANICAL ROOM 453
GENERAL NOTES:
1. ALL DUCTWORK SHOWN ON THIS FLOOR SHALL BE EXISTING TO REMAIN. DUCTWORK IS
SHOWN ONLY TO DEMONSTRATE APPROXIMATE SCOPE OF DUCT CLEANING
REQUIREMENTS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN FIELD.
2. CLEAN ALL SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR DUCTWORK IN ACCORDANCE
WITH SPECIFICATIONS.
3. ALL DIFFUSERS SHALL BE CLEANED BEFORE BEING REPLACED IN CEILING.
4. FIRE AND SMOKE DAMPERS SHOWN ON THIS PLAN SHALL NOT BE CONSIDERED TO BE A
COMPLETE INVENTORY OF ALL EXISTING DAMPERS.
5. CONTRACTOR SHALL TEST ALL FIRE AND SMOKE DAMPERS ON ALL FLOORS, WHETHER
INDICATED ON DRAWINGS OR NOT. CONTRACTOR SHALL INDICATE ANY INACCESSIBLE
DAMPERS IN THE TESTING PROCEDURE DOCUMENTATION. CONTRACTOR SHALL
CREATE A FINAL REPORT NOTING WHETHER DAMPERS WERE FOUND OR NOT.
6. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS OF EXACT LOCATIONS OF FIRE AND
SMOKE DAMPERS UPON COMPLETION OF PROJECT.
7. CONTRACTOR SHALL IDENTIFY ANY DAMAGES TO EXISTING ACCESS DOORS WHILE
SURVEYING THE FIRE DAMPERS AND INCLUDE THESE DAMAGES IN FINAL REPORT.
8. THE FACILITY WILL BE OCCUPIED AND OPERATING DURING THE DURATION OF THE
PROJECT. REFER TO SHEET H1 FOR ALLOWABLE WORK HOURS FOR EACH BUILDING.
ELECTRICAL NOTES:
1. ALL ELECTRICAL FED FIRE/SMOKE DAMPERS IN AREA OF WORK SHALL BE DE-ENERGIZED BEFORE
PERFORMING ANY CLEANING OR WORK.
2. MOTORS (EQUIPMENT) FEEDING DUCTS SHALL BE SHUTDOWN PRIOR TO CLEANING AND TESTING.
3. LOCKOUT/TAGOUT PROCEDURES SHALL BE STRICTLY ENFORCED.
4. RE-ENERGIZED DAMPERS ONCE WORK ON SECTION IS COMPLETE.
SCALE: 1/8" = 1'-0"2
PART FOURTH FLOOR PLAN - MECHANICAL ROOM 453
HVAC - DEMOLITION
SCALE: 1/8" = 1'-0"3
PART FOURTH FLOOR PLAN - MECHANICAL ROOM 453
HVAC - NEW WORK
SCALE: 1/8" = 1'-0"4
SECTION 1 - EXHAUST DUCTWORK
HVAC - NEW WORK
ADDITIONAL HVAC SCOPE:
1. REMOVE AND REPLACE EXISTING NON-FUNCTIONAL FIRE DAMPER ASSOCIATED
WITH EXISTING AHU-3 AT FLOOR PENETRATION IN 52x20 SUPPLY DUCT.
CONTRACTOR TO VERIFY EXACT DUCT SIZE.
2. REMOVE AND REPLACE EXISTING NON-FUNCTIONAL FIRE DAMPER ASSOCIATED
WITH EXISTING AHU-3 AT FLOOR PENETRATION IN 46x24 RETURN DUCT.
CONTRACTOR TO VERIFY EXACT DUCT SIZE.
3. REMOVE AND REPLACE EXISTING NON-FUNCTIONAL FIRE DAMPER ASSOCIATED
WITH EXISTING AHU-5 AT FLOOR PENETRATION IN 42x20 SUPPLY DUCT.
CONTRACTOR TO VERIFY EXACT DUCT SIZE.
4. REMOVE AND REPLACE EXISTING NON-FUNCTIONAL FIRE DAMPER ASSOCIATED
WITH EXISTING AHU-5 AT FLOOR PENETRATION IN 34x20 RETURN DUCT.
CONTRACTOR TO VERIFY EXACT DUCT SIZE.
5. REFER TO HVAC PART PLANS AND SECTION ON THIS SHEET FOR WORK IN THIS
AREA.
6. REMOVE EXISTING 14x12 STAINLESS STEEL EXHAUST DUCT FROM EXISTING FAN
EF-14 UP TO AND INCLUDING EXISTING FIRE DAMPER AT FLOOR PENETRATION.
7. INSTALL NEW 14x12 GALVANIZED EXHAUST DUCT AS REQUIRED TO PROVIDE
ADEQUATE ACCESS TO FIRE DAMPERS AT FLOOR PENETRATIONS. REFER TO
HVAC SECTION FOR ADDITIONAL REQUIREMENTS.
8. INSTALL NEW 14x12 GALVANIZED EXHAUST DUCT AS CLOSE TO FLOOR AS
POSSIBLE.
9. REPLACE EXISTING FIRE DAMPER AT FLOOR PENETRATION OF 14x12 EXHAUST
DUCT.
10. TEST AND CONFIRM OPERATION OF EXISTING FIRE DAMPER AT FLOOR
PENETRATION OF EXISTING 14x14 EXHAUST DUCT. REPLACE DAMPER IF
NON-FUNCTIONAL.
11. INSTALL NEW 12x12 ACCESS DOOR IN HORIZONTAL FACE OF NEW DUCT ELBOW
WHERE INDICATED. PROVIDE RECTANGULAR 90 DEGREE ELBOW WITHOUT
TURNING VANES TO ACCOMMODATE ACCESS.
12. INSTALL NEW 12x12 ACCESS DOOR IN VERTICAL FACE OF EXISTING 14x14
EXHAUST DUCT. LOCATE AS LOW ON DUCT AS POSSIBLE.
REVISION 1 09/27/2021
** DAMPER FUNCTIONAL. NOT REPLACED. **
** DAMPER FUNCTIONAL. NOT REPLACED. **
** DAMPER FUNCTIONAL. NOT REPLACED. **
5C01
5A055A065A08
5A095A10
5A13
5A14 5A165A175A20
5A19 5A15 5A11 5A07 5A07A HEARTH ROOM
5A03
5B03
5B07 5B08 5B11
5B13
5B16 5B19
5B21
5B185B17
5B15
5B125B105B095B06
5B05
5B04
5A01A5A02
STAIR
C5
STAIR
B5
STAIR
A5
5A19A 5A15A 5A11A 5B03A 5B07A 5B08A 5B11A
5B13A
5B16A 5B19A
5B18A5B17A 5B10A
5B09A5B06A
5B02
5A18
5A16A
5A12
FIRE EQUIPMENT
5A04
RECEPTION
5A01
5B14
5B20
5B01
CORRIDOR
5A1
CORRIDOR
5A2
CORRIDOR
5B1
CORRIDOR
5B2
S4
P3
P2
16"Ø 14"Ø
14x88x8
12"Ø
10"Ø
10x8
12"Ø
14"Ø 20x30
16"Ø
16"Ø
14x8
20x8 20x10
20x8 24x8 24x8
10x6
14x8
16x10
14"Ø
14"Ø
16x30
20x8
20x8 12x8
14"Ø
23x13 10"Ø
10"Ø6x8 22x10
28x10
40x6
18"Ø 14"Ø
16"Ø
28x24
10x6
10x6
10x6
10x6
10x6
10x6
10x6
10x6 10x6
18x6
18x6
18x6
18x6
12x6
12x6 12x6
12x6
10x10
12x12
14x10 10x10 8x8
10x1010x10 8x10
10x10
10x10
10x10
10x10
12"Ø
14x10
10x10
14x10
10x10
10x10
10x10
10x10
10x10
10x10
14x10
10x10
9"Ø
10x8
9"Ø
10x10
12"Ø
10x10
10x10
10x10 10x10
9"Ø
10x8 10x8
8"Ø
14x8 10x6
10x6
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .