This federal contract opportunity solicitation seeks proposals to renovate the urgent care and registration areas at facility 553-19-104 for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10. Offerors are invited to submit proposals under solicitation number 36C25023B0009 by the unspecified due date to modernize and improve the urgent care and registration spaces. The work includes general construction and renovation services to upgrade the designated areas for improved patient experience and care delivery.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. ALL REFERENCES TO OWNER IN THESE DOCUMENTS REFER TO THE
VA, THE CO AND/OR THE COR.
2. ALL REFERENCES TO GOVERNMENT IN THESE DOCUMENTS REFER
TO THE VA, THE CO AND/OR THE COR.
3. PRODUCTS LISTED HEREIN BY MANUFACTURER'S TRADE NAME AND
NUMBERS ARE TO BE USED FOR BASIS OF DESIGN ONLY, U.N.O.
PRODUCTS ARE SUBJECT TO COMPLIANCE WITH SALIENT
CHARACTERISTICS AND REQUIREMENTS IN THE SPECIFICATIONS.
PROVIDE PRODUCTS LISTED OR COMPARABLE PRODUCTS BY OTHER
MANUFACTURERS.
GENERAL NOTES:
N
EW
S
LAKE ERIE
GRAND
RAPIDS
TRAVERSE
CITY
LAKE SUPERIOR
UPPER PENINSULA
MACKINAW
CITY LAKE HURO
N
ALPENA
PETOSKEY
GAYLORD
GRAYLING
LA
K
E M
IC
H
IG
A
N
SAGINAW
FLINT
LANSING
DETROIT
KALAMAZOO
ANN
ARBOR
BATTLE
CREEK
LOCATION MAP
NOT TO SCALE
N
EW
S
CAMPUS MAP
NOT TO SCALE
SOUTH
PARKING
DECK
E N
E R
G Y
C E
N
TE
R
NORTH
PARKING
DECK
E. W
ARREN AVE.
E. H
ANCOCK ST.
E. C
ANFIELD ST.
JO
H
N R
S T.
B R
U S
H S
T.
S T. A
N
TO
IN
E
W O
O D
W A
R D
A V
E . E. F
OREST ST.
W. F
OREST ST.
N
EW
S
VICINITY MAP
NOT TO SCALE
W. F
ORT ST.
MICHIGAN AVE. 1212
W . G
R A
N D
B
LV
D
MARTIN LUTHER KING JR. BLVD.
W. W
ARREN AVE.
W O
O D
W A
R D
A V
E
W. G
RAND BLVD.
W. GRAND RIVER AVE.
G R
A
TI
O T
A V
E
DETROIT RIVER
M C
D O
U G
A
LL S
T
E. G
RAND BLVD.
E. G
RAND BLVD. E. G
RAND BLVD.
V A
N D
Y K
E
E. W
ARREN AVE.
MACK AVE. VERNOR HWY.
E. LAFAYETTE ST.
E. JEFFERSON AVE.
DETROIT
R A
IL
R
O A
D architecture · engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERS · SURVEYORS · CONSULTANTS ·
LANDSCAPE ARCHITECTS · LAND PLANNERS
298 VETERANS DRIVE
FOWLERVILLE,
MICHIGAN 48836
(OFFICE) 517-223-3512
(FAX) 517-223-9987
211 E. Water Street, Suite 213L
Kalamazoo, MI 49007 269.216.0222
VA STATION
Defining
EXCELLENCE
in the 21st Century
HEALTH
CARE
SIGNATURE DATE
Director
Associated Director
Chief of Staff
Associate Director for Patient Care Services
Chief, FMS
Chief, Engineering Section
Chief, Police Service
Chief, Fire Service
Union Safety Representative
Chief, Environmental Management Section
Infection Control Officer
Patient Safety Manager
GEMS Coordinator
Safety Specialist
Contracting Officer
COR
SIGNATURE BLOCK
POSITION DATESIGNATUREPOSITION
DEPARTMENT OF VETERANS AFFAIRS - JOHN D. DINGELL VA MEDICAL CENTER
DETROIT, MICHIGAN
John D. Dingell VA Medical Center
4646 John R. Street
Detroit, MI 48201
C :\U se rs
\M ic he lle
.b ur ri\ D oc um en ts
\1
5_
A _m ic he lle .b ur ri.
rv t
4/
/2
2:
:0
P
M
G-001
COVER SHEET RENOVATE URGENT CARE AND
REGISTRATION
DETROIT, MI
553-19-104
25MAR2022 KJH MRB
100% BID DOCUMENTS190075
RENOVATE URGENT CARE AND
REGISTRATION
553-19-104
25MAR2022
100% BID DOCUMENTS
553-19-104
SHEET LIST
SHEET
NO. SHEET NAME
GENERAL
G-001 COVER SHEET
G-101 LIFE SAFETY PLAN - FIRST LEVEL - PARTIAL ZONE 7
G-102 INFECTION CONTROL RISK ASSESSMENT (ICRA) PLANS
G-103 INFECTION CONTROL RISK ASSESSMENT (ICRA) PLANS
STRUCTURAL
S-001 GENERAL NOTES AND LEGENDS
S-110.7B SLAB PLAN - LOWER LEVEL - ZONE 7B
S-110.I.7B INTERSTITIAL FRAMING PLAN - LOWER LEVEL - ZONE 7B
S-111.7A FRAMING PLAN - FIRST LEVEL - ZONE 7A
S-111.7B FRAMING PLAN - FIRST LEVEL - ZONE 7B
S-111.I.7A INTERSTITIAL FRAMING PLAN - FIRST LEVEL - ZONE 7A
S-111.I.7B INTERSTITIAL FRAMING PLAN - FIRST LEVEL - ZONE 7B
S-501 DETAILS
S-502 DETAILS
ARCHITECTURAL
A-001 ARCHITECTURAL LEGENDS, SYMBOLS, AND ABBREVIATIONS
A-002 PARTITION TYPES
AD100 DEMO PLAN - LOWER LEVEL - PARTIAL ZONE 7
AD100.I DEMO PLAN - LOWER LEVEL INTERSTITIAL - PARTIAL ZONE 7
AD101 DEMO PLAN - FIRST LEVEL - PARTIAL ZONE 7
AD101.I DEMO PLAN - FIRST LEVEL INTERSTITIAL - PARTIAL ZONE 7
AD121 DEMOLITION RCP - FIRST LEVEL PARTIAL ZONE 7
A-100 FLOOR PLAN - LOWER LEVEL - PARTIAL ZONE 7
A-100.I FLOOR PLAN - LOWER LEVEL INTERSTITIAL - PARTIAL ZONE 7
A-101 FLOOR PLAN - FIRST LEVEL - PARTIAL ZONE 7
A-101.I FLOOR PLAN - FIRST LEVEL INTERSTITIAL - PARTIAL ZONE 7
A-111.7A FLOOR PLAN - FIRST LEVEL - ZONE 7A
A-111.7B FLOOR PLAN - FIRST LEVEL - ZONE 7B
A-121 REFLECTED CEILING PLAN - FIRST LEVEL - PARTIAL ZONE 7
A-130.7B REFLECTED CEILING PLAN - LOWER LEVEL - ZONE 7B
A-131.7A REFLECTED CEILING PLAN - FIRST LEVEL - ZONE 7A
A-131.7B REFLECTED CEILING PLAN - FIRST LEVEL - ZONE 7B
A-141.7A EQUIPMENT PLAN - FIRST LEVEL - ZONE 7A
A-141.7B EQUIPMENT PLAN - FIRST LEVEL - ZONE 7B
A-401 INTERIOR ELEVATIONS OBSERVATION UNIT- ZONE 7A
A-402 INTERIOR ELEVATIONS OBSERVATION UNIT- ZONE 7A
A-403 INTERIOR ELEVATIONS FAST TRACK - ZONE 7A
A-404 INTERIOR ELEVATIONS FAST TRACK - ZONE 7A
A-405 INTERIOR ELEVATIONS REGISTRATION - ZONE 7B
A-406 INTERIOR ELEVATIONS REGISTRATION - ZONE 7B
A-407 INTERIOR ELEVATIONS REGISTRATION - ZONE 7B
A-501 SECTIONS
A-502 SECTIONS AND DETAILS
A-503 DETAILS
A-504 INTERIOR DETAILS & ELEVATIONS
A-505 INTERIOR DETAILS
A-506 INTERIOR DETAILS
A-601 SCHEDULES & DIAGRAMS
A-602 DOOR DETAILS
INTERIORS
I-100 FINISH PLAN - LOWER LEVEL - PARTIAL ZONE 7
I-101.7A FINISH PLAN - FIRST LEVEL - ZONE 7A
I-101.7B FINISH PLAN - FIRST LEVEL - ZONE 7B
I-121 SIGNAGE PLAN - FIRST LEVEL - PARTIAL ZONE 7
I-122 SIGNAGE DETAILS
I-601 INTERIORS SCHEDULES
Revisions: Date:
SHEET LIST
SHEET
NO. SHEET NAME
FIRE PROTECTION PLAN
FPD101 FIRE PROTECTION DEMO PLAN - FIRST LEVEL - PARTIAL ZONE 7
FP101 FIRE PROTECTION PLAN - FIRST LEVEL - PARTIAL ZONE 7
PLUMBING
PD101 WASTE AND VENT DEMO PLAN - FIRST LEVEL - PARTIAL ZONE 7
PD102 DOMESTIC WATER DEMO PLAN - FIRST LEVEL - PARTIAL ZONE 7
PD103 MEDICAL GAS DEMO PLAN - FIRST LEVEL - PARTIAL ZONE 7
P-101 WASTE AND VENT PLAN - FIRST LEVEL - PARTIAL ZONE 7
P-102 DOMESTIC WATER PLAN - FIRST LEVEL - PARTIAL ZONE 7
P-103 MEDICAL GAS PLAN - FIRST LEVEL - PARTIAL ZONE 7
P-400 PLUMBING ENLARGED PLANS
P-500 PLUMBING DETAILS AND SCHEDULES
MECHANICAL
M-000 MECHANICAL GENERAL INFORMATION
MD101 HVAC DEMO PLAN - FIRST LEVEL - PARTIAL ZONE 7
MPD101 MECHANICAL PIPING DEMO PLAN - FIRST LEVEL - PARTIAL ZONE 7
MH101 HVAC PLAN - FIRST LEVEL - PARTIAL ZONE 7
MP101 MECHANICAL PIPING PLAN - FIRST LEVEL - PARTIAL ZONE 7
M-500 MECHANICAL DETAILS
M-600 MECHANICAL SCHEDULES AND TEMPERATURE CONTROLS
ELECTRICAL
E-001 ELECTRICAL GENERAL INFORMATION
E-002 LIGHTING SCHEDULES
ED100 DEMO PLAN - LOWER LEVEL - PARTIAL ZONE 7
ED100.I DEMO PLAN -LOWER LEVEL INTERSTITIAL - PARTIAL ZONE 7
ED101 DEMO PLAN - FIRST LEVEL - PARTIAL ZONE 7
ED101.I DEMO PLAN - FIRST LEVEL INTERSTITIAL - PARTIAL ZONE 7
EL400.7B LIGHTING PLAN - LOWER LEVEL - ZONE 7B
EL401.7A LIGHTING PLAN - FIRST LEVEL - ZONE 7A
EL401.7B LIGHTING PLAN- FIRST LEVEL - ZONE 7B
EP400.7B POWER PLAN - LOWER LEVEL - ZONE 7B
EP401.7A POWER/SYSTEMS PLAN - FIRST LEVEL - ZONE 7A
EP401.7B POWER/SYSTEMS PLAN - FIRST LEVEL- ZONE 7B
E-201 ELEVATIONS
E-500 ELECTRICAL DETAILS
E-501 ELECTRICAL DETAILS
E-600 PANEL SCHEDULES
E-601 PANEL SCHEDULES
TOTAL SHEETS: 87
ST
ATE OF MICHIGAN
L
IC
E N
SED PROFESSIONA L E
N G
IN
E
E
RENGINEER
No.
51101
NATHANIEL
STALKER
03/25/2022
ST
ATE OF MICHIGAN
L
IC
E N
SED PROFESSIONA L E
N G
IN
E
E
RENGINEER
No.
50400
SCOTT E.
TOWNSEND
03/25/2022
NIC
NIC
SMOKE COMPARTMENT ZONE 11
SMOKE COMPARTMENT ZONE 1.3
SMOKE COMPARTMENT ZONE 1.6
SMOKE COMPARTMENT
ZONE 1.7
90'
75'
28'
HORZ FOLDING FIRE DOORHORZ FOLDING FIRE DOOR
170 OCC
170 OCC
460 OCC
460 OCC
460 OCC460 OCC OBSERVATION
FAST TRACK
CARE
REGISTRATION
NIC
MIN
MIN
MIN
MIN
MIN
MIN
MIN
MIN
MIN
167 SF
120 GSF
180 SF
120 GSF
172 SF
120 GSF
164 SF
120 GSF
154 SF
120 GSF
154 SF
120 GSF
111 SF
50 GSF
98 SF
50 GSF
91 SF
50 GSF
64 SF
50 GSF
216 SF
15 NSF
123 SF
50 GSF
40 SF
500 GSF
89 SF
150 GSF
33 SF
500 GSF
91 SF
150 GSF
94 SF
500 GSF
127 SF
50 GSF
123 SF
50 GSF
148 SF
50 GSF
84 SF
500 GSF
106 SF
150 GSF
101 SF
150 GSF
63 SF
500 GSF
57 SF
150 GSF
117 SF
150 GSF
361 SF
150 GSF
170 SF
15 NSF
58 SF
150 GSF
591 SF
150 GSF
200 SF
15 NSF
316 SF
30 GSF
155 SF
150 GSF
281 SF
500 GSF
72 SF
50 GSF
72 SF
50 GSF
72 SF
50 GSF
72 SF
50 GSF
72 SF
50 GSF
72 SF
50 GSF
72 SF
50 GSF
72 SF
50 GSF
72 SF
50 GSF
72 SF
50 GSF
72 SF
50 GSF
69 SF
50 GSF
495 SF
15 NSF
FEC FHC
FE
C
187 SF
150 GSF
MIN
MIN
FE
PARTITION / WALL FIRE RATINGS
2-HR. FIRE BARRIER EXISTING 2-HR. FIRE BARRIER
NOTE: EXISTING RATED WALL SHOWN SCREENED ON PLAN. - V.I.F. WALLS MEET DESIGNATED
REQUIREMENTS & ADD OPENING & PENETRATION PROTECTIVES AS REQ'D
SMOKE COMPARTMENT AREAS
SMOKE COMPARTMENT ZONE 1.6 SMOKE COMPARTMENT ZONE 11 SMOKE COMPARTMENT ZONE 1.3
EXIST COMPARTMENT = 18,950 SF EXIST COMPARTMENT = 15,135 SF NO CHANGES
NEW COMPARTMENT = 17,770 SF NEW COMPARTMENT = 17,220 SF
1-HR. SMOKE BARRIER
NON-RATED
SMOKE PARTITION
EXISTING 1-HR. SMOKE BARRIER
EXISTING NON-RATED
SMOKE PARTITION
APPLICABLE CODES AND STANDARDS
BUILDING CODES: EDITION
· NFPA 101 LIFE SAFETY CODE 2021
· NFPA NATIONAL FIRE CODES, WITH EXCEPTION OF NFPA 5000 AND NFPA 900
· INTERNATIONAL BUILDING CODE (IBC) 2018
· ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS)
· VA BARRIER FREE DESIGN STANDARD (PG-18-13, SUPPLEMENT TO THE ABAAS)
PLUMBING CODE:
· INTERNATIONAL PLUMBING CODE (IPC) 2018
HVAC CODE:
· ASME BOILER AND PRESSURE VESSEL CODE
· ASME CODE FOR PRESSURE PIPING
· ASHRAE STANDARD 62.1 - VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY 2004
· ASHRAE STANDARD 15 - SAFETY STANDARD FOR REFRIGERATION SYSTEMS 2007
ELECTRICAL CODE:
· NATIONAL ELECTRICAL CODE (NEC - NFPA 70) 2020
OCCUPANCY CLASSIFICATION (NFPA 101: 6.1):
· HEALTH CARE (UNCHANGED)
BUILDING AREA:
· EXISTING BUILDING AREA: (UNCHANGED)
· AREA OF RENOVATION: 13,570 SF
TYPES OF CONSTRUCTION (NFPA 101: 18.1.6):
· II (222) (UNCHANGED)
AUTOMATIC SPRINKLER SYSTEM (NFPA 101: 9.7):
· EXISTING BUILDING FULLY SPRINKLED
· RENOVATION TO REWORK EXISTING SYSTEM FOR PLAN CHANGES
FIRE ALARM SYSTEM AND SMOKE DETECTION (NFPA 101: 9.6):
· EXISTING BUILDING FULLY ALARMED WITH SMOKE DETECTION
· RENOVATION TO REWORK AND TIE INTO EXISTING FIRE ALARM SYSTEM AND SMOKE DETECTION FOR PLAN
CHANGES
EGRESS REQUIREMENTS:
· EGRESS CAPACITY(LEVEL COMPONENTS & RAMPS) = 0.2"/OCCUPANT (NFPA 101: 7.3.3)
· COMMON PATH OF TRAVEL = 100' (NFPA 101: 18.2.5.2)
· DEAD ENDED CORRIDOR = 30' MAX (NFPA 101: 18.2.5.3)
· TRAVEL DISTANCE TO EXITS = 200' MAX (NFPA 101: 18.2.6.2)
OCCUPANT LOADS FOR EGRESS (NFPA 101: 7.3.1.2):
· REGISTRATION SUITE: 95 TOTAL OCCUPANTS
· FAST TRACK / OBSERVATION SUITE: 53 TOTAL OCCUPANTS
· ADDITIONAL OCCUPANTS TO SMOKE COMPARTMENT ZONE 11: 18 OCCUPANTS
NOTE: REFER TO INDIVIDUAL OCCUPANCY SYMBOLS ON PLANS FOR INDIVIDUAL ROOM OCCUPANCIES
SUITES (NFPA 101: 18.2.5.7):
· PATIENT CARE SLEEPING SUITE (OBSERVATION/FAST CARE SUITE):
MAX ALLOWABLE = 7,500 SF ACTUAL = 4,635 SF
· PATIENT CARE NONSLEEPING SUITE (REGISTRATION SUITE):
MAX ALLOWABLE = 12,500 SF ACTUAL = 5,397 SF
CODE SUMMARY
FIRE EXTINGUISHER CABINET
SYMBOL LEGEND
DIST. TO
EXIT
PERSONS
TO EXIT EGRESS PATH COMPUTATION
EXIT
FEC
FIRE PROOFING NOTES
PROVIDE SPRAY APPLIED FIRE RESISTANT MATERIAL TO ALL STEEL COLUMNS, STEEL BEAMS, LINTELS, STEEL DECK AND ANY MISC. STRUCTURAL STEEL. ALL STEEL STRUCTURAL MEMBERS SHALL BE
INDIVIDUALLY PROTECTED ON ALL SIDES FOR THEIR FULL LENGTH.
FIRE RESISTANCE RATINGS FOR TYPE II (222)
COLUMNS (FLOOR LEVEL & INTERSTITIAL) - 2 HR
BEAMS, GIRDERS, AND TRUSSES (FLOOR LEVEL & INTERSTITIAL) - 2 HR
FLOOR DECK (FLOOR LEVEL, NOT INTERSTITIAL) - 2 HR
SMOKE COMPARTMENT SEPARATION
# - MAX EGRESS
CAPACITY
FAST TRACK CARE & OBSERVATION SUITE
REGISTRATION SUITE
1-HR. FIRE BARRIER EXISTING 1-HR. FIRE BARRIER
FIRE EXTINGUISHER
FE
FIRE HOSE CABINET
FHC
### SF
500 GSF
STORAGE:
IN OTHER THAN STORAGE AND
MERCANTILE OCCUPANCIES
ROOMS 500 SF GROSS / PERSON
ASSEMBLY:
LESS CONCENTRATED (WITHOUT
FIXED SEATING)
15 SF NET / PERSON
S/M
### SF
15 NSF
LC
MAX. FLOOR AREA ALLOWANCES PER OCCUPANT AND FUNCTION OF SPACES
NFPA OCCUPANCY SYMBOL LEGEND
### SF
50 GSF
BUSINESS USE:
CONCENTRATED
50 SF GROSS / PERSON
### SF
150 GSF
BUSINESS USE:
UNCONCENTRATED
150 SF GROSS / PERSON
HEALTHCARE:
SLEEPING DEPARTMENTS:
120 SF GROSS / PERSON
120 GSF
### SF ### SF
30 GSF
BUSINESS USE:
COLLABORATION ROOMS /
SPACES ≤ 450 SF IN AREA
30 SF GROSS / PERSON
N KEY PLAN
NOT TO SCALE
SOUTH
PARKING
DECK
ENERGY
CENTER
NORTH
PARKING
DECK
9A architecture · engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERS · SURVEYORS · CONSULTANTS ·
LANDSCAPE ARCHITECTS · LAND PLANNERS
298 VETERANS DRIVE
FOWLERVILLE,
MICHIGAN 48836
(OFFICE) 517-223-3512
(FAX) 517-223-9987
211 E. Water Street, Suite 213L
Kalamazoo, MI 49007 269.216.0222
VA STATION
Defining
EXCELLENCE
in the 21st Century
HEALTH
CARE
John D. Dingell VA Medical Center
4646 John R. Street
Detroit, MI 48201
C :\U se rs
\M ic he lle
.b ur ri\ D oc um en ts
\1
5_
A _m ic he lle .b ur ri.
rv t
4/
/2
2:
:0
P
M
G-101
LIFE SAFETY PLAN - FIRST LEVEL
- PARTIAL ZONE 7
RENOVATE URGENT CARE AND
REGISTRATION
DETROIT, MI
553-19-104
25MAR2022 Checker Author
100% BID DOCUMENTS190075
3/32" = 1'-0"
PARTIAL FIRST FLOOR LIFE SAFETY PLAN - ZONE 5/7
Revisions: Date:
F
G
H
J
J.1
G.3
5.6
E.5
F.4
PROVIDE ADHESIVE
WALK-OFF MATS, TYP.
PROVIDE TEMPORARY PROTECTIVE
PLASTIC BARRIER WITH ZIPPERED ENTRY
FROM FLOOR TO THE BOTTOM OF THE
CEILING.
AREA OF WORK
ONE HOUR FIRE RATED
CONSTRUCTION BARRIER
NIC
E
F
G
H
J
J.1
G.3
F.4
NIC
PROVIDE ADHESIVE
WALK-OFF MATS, TYP.
AREA OF WORK
AREA OF WORK
INFECTION CONTROL RISK MITIGATION RECOMMENDATIONS MATRIX OF PRECAUTIONS
FOR CONSTRUCTION AND RENOVATION
TYPE OF CONSTRUCTION / PROJECT ACTIVITY TABLE
INSPECTION AND NON-INVASIVE ACTIVITIES
INCLUDES, BUT IS NOT LIMITED TO:
- REMOVAL OF CEILING TILES FOR VISUAL INSPECTION LIMITED TO 20 LN FT TILE PER 160 SQ. FT. SPACE.
- PAINTING (BUT NOT SANDING)
- WALLCOVERING, ELECTRICAL TRIM WORK, MINOR PLUMBING, AND ACTIVITIES WHICH NO NOT GENERATE DUST OR REQUIRE CUTTING OF WALLS OR ACCESS TO CEILINGS OTHER THAN FOR VISUAL INSPECTION
- PATCHING WALLS - NOT EXCEEDING 8 SQ FT
TYPE
A
SMALL SCALE, SHORT DURATION ACTIVITIES WHICH CREATE MINIMAL DUST
INCLUDES, BUT IS NOT LIMITED TO:
- INSTALLATION OF TELEPHONE AND COMPUTER CABLING
- ACCESS TO CHASE SPACES
- CUTTING OF WALLS OR CEILING WHERE DUST MIGRATION CAN BE CONTROLLED
- PATCHING WALLS - EXCEEDING 8 SQ FT
TYPE
B
WORK THAT GENERATES A MODERATE TO HIGH LEVEL OF DUST OR REQUIRES DEMOLITION OR REMOVAL OF ANY
FIXED BUILDING COMPONENTS AND ASSEMBLIES OR NEW CONSTRUCTION
INCLUDES, BUT IS NOT LIMITED TO:
- SANDING OF WALLS FOR PAINTING OR WALL COVERING EXCEEDING 32 SQ. FT., OR VACANT AREAS
- REMOVAL OF FLOOR COVERINGS, CEILING TILES AND CASEWORK
- NEW WALL CONSTRUCTION
- UNCONTAINED DUCT, HVAC OR ELECTRICAL WORK ABOVE CEILINGS
- MAJOR CABLING ACTIVITIES
- ANY OTHER PROJECT WHERE HIGH LEVELS OR DUST ARE GENERATED
TYPE
C
MAJOR DEMOLITION AND CONSTRUCTION PROJECTS
INCLUDES, BUT IS NOT LIMITED TO:
- ACTIVITIES THAT REQUIRE CONSECUTIVE WORK SHIFTS
- REQUIRES HEAVY DEMOLITION OR REMOVAL OF A COMPLETE CABLING SYSTEM
- NEW CONSTRUCTION
TYPE
D
PATIENT RISK GROUP TABLE
- ADMINISTRATIVE OFFICES
- PUBLIC CORRIDORS
- ELEVATORS
- DAY ROOMS
- CANTEEN RETAIL STORE
- VACANT WARDS OR VACANT
ICU'S ETC.
GROUP 1
LOW RISK
- OUTPATIENT, URGENT CARE &
PRIMARY CARE CLINICS
- LABORATORY
- CARDIOLOGY
- ECHOCARDIOGRAPHY
- ENDOSCOPY
- FOOD SERVICES
- INTERIM CARE & MEDICAL
UNITS
- NUCLEAR MEDICINE
- PHARMACY
- PHYSICAL THERAPY
- RADIOLOGY & NUCLEAR
MEDICINE
- RESPIRATORY THERAPY
GROUP 2
MEDIUM RISK
- CCU
- EMERGENCY ROOM
- LABORATORY
- OUTPATIENT SURGERY
- PHARMACY
- POST ANESTHESIA CARE UNIT
- SURGICAL UNITS
GROUP 3
HIGH RISK
- ANY AREA CARING FOR
IMMUNICOMPROMISED
PATIENTS
- SPD STORAGE / STERILIZATION
- INTENSIVE CARE UNITS
- TB NEGATIVE PRESSURE
ISOLATION ROOMS
- OPERATING ROOM
GROUP 4
HIGHEST RISK
INFECTION CONTROL MATRIX - CLASS OF PRECAUTIONS:
CONSTRUCTION PROJECT BY PATIENT RISK
PATIENT RISK GROUP
CONSTRUCTION PROJECT TYPE
TYPE A
LOW RISK GROUP 1
MEDIUM RISK GROUP 2
HIGH RISK GROUP 3
HIGHEST RISK GROUP 4
TYPE B TYPE C TYPE D
I II II III / IV
I II II IV
I II III / IV IV
II III / IV III / IV IV
NOTE: INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY
AND RISK LEVEL INDICATE THAT CLASS III OR IV CONTROL PROCEDURES ARE NECESSARY
IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE FOLLOWING INFECTION
CONTROL PRECAUTIONS DEPENDING UPON
THE AREA CLASS DESIGNATION
DURING CONSTRUCTION PROJECT
1. EXECUTE WORK BY METHODS TO MINIMIZE RAISING
DUST FROM CONSTRUCTION OPERATIONS.
2. IMMEDIATELY REPLACE A CEILING TILE DISPLACED
FOR VISUAL INSPECTIONS.
C L
A S
S I
UPON COMPLETION OF PROJECT
1. PROVIDE ACTIVE MEANS TO PREVENT AIRBORNE DUST FROM
DISPERSING INTO ATMOSPHERE.
2. WATER MIST WORK SURFACES TO CONTROL DUST WHILE
CUTTING.
3. SEAL UNUSED DOORS WITH DUCT TAPE.
4. BLOCK OFF AND SEAL AIR VENTS.
5. PLACE DUST MAT AT ENTRANCE AND EXIT OF WORK AREA.
6. REMOVE OR ISOLATE HVAC SYSTEM IN AREAS WHERE WORK
IS BEING PERFORMED.
C L
A S
S I
I
1. WIPE WORK SURFACES WITH DISINFECTANT.
2. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN
TIGHTLY COVERED CONTAINERS.
3. WIPE WORK SURFACES WITH DISINFECTANT, WET MOP AND /
OR VACUUM WITH HEPA VACUUM BEFORE LEAVING WORK
AREA.
4. REMOVE ISOLATION OF HVAC.
1. REMOVE OR ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS
BEING DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM.
2. COMPLETE ALL CRITICAL BARRIERS, I.E., SHEETROCK,
PLYWOOD, PLASTIC, TO SEAL AREA FROM NON-WORK AREA OR
IMPLEMENT CONTROL CUBE METHOD (CART WITH PLASTIC
COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA
VACUUM FOR VACUUMING PRIOR TO EXIT) BEFORE
CONSTRUCTION BEGINS.
3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE
UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS.
4. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN
TIGHTLY COVERED CONTAINERS.
5. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE
COVERING UNLESS SOLID LID.
C L
A S
S I
II
1. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL
COMPLETED PROJECT IS INSPECTED BY THE ENVIRONMENTAL
HEALTH AND SAFETY AND INFECTION CONTROL AND
THOROUGHLY CLEANED BY ENVIRONMENTAL SANITATION
SECTION.
2. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE
SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH
CONSTRUCTION.
3. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS.
4. WET MOP AREA WITH DISINFECTANT.
5. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE
WORK IS BEING PERFORMED.
1. OBTAIN INFECTION CONTROL PERMIT BEFORE
CONSTRUCTION BEGINS.
2. ISOLATE HVAC SYSTEMS IN AREA WHERE WORK IS BEING
DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM.
3. COMPLETE ALL CRITICAL BARRIERS OR IMPLEMENT CONTROL
CUBE METHOD BEFORE CONSTRUCTION BEGINS.
4. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE
UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS.
5. SEAL HOLES, PIPES, CONDUITS AND PUNCTURES
APPROPRIATELY.
6. CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO
PASS THROUGH THIS ROOM SO THEY CAN BE VACUUMED USING
A HEPA VACUUM CLEANER BEFORE LEAVING WORK SITE OR
THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE
REMOVED EACH TIME THEY LEAVE THE WORK SITE.
7. ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO
WEAR SHOE COVERS.
C L
A S
S
IV
1. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL
COMPLETED PROJECT IS THOROUGHLY CLEANED BY
ENVIRONMENTAL MANAGEMENT.
2. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS.
3. WET MOP AREA WITH DISINFECTANT.
4. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE
SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH
CONSTRUCTION.
5. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN
TIGHTLY COVERED CONTAINERS.
6. COVER TRANSPORT RECEPTACLES OR CARTS, TAPE
COVERING.
7. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE
WORK IS BEING PERFORMED.
1. VA PREFERS THE USE OF HARD WALL PARTITIONS OVER
THE USE OF PLASTIC SHEETING FOR SEPARATION
BETWEEN CONSTRUCTION AND EXISTING SPACES TO
REMAIN FUNCTIONING. CONTRACTOR TO SUBMIT
PROPOSED PLAN FOR TEMPORARY CONSTRUCTION
PARTITION LOCATIONS FOR COR APPROVAL. TEMPORARY
PARTITION LOCATIONS SHOWN HERE ARE RECOMMENDED
LOCATIONS BASED ON WORK NEEDING TO BE COMPLETED,
BUT DOES NOT CONSTITUTE FINAL LOCATIONS OR
QUANTITIES.
2. CONTRACTOR TO VERIFY IF EXISTING WALLS CALLED OUT
TO BE 1 HR FIRE RATED CONSTRUCTION BARRIERS MEET
THE REQUIREMENTS OF A 1 HR FIRE RATED WALL. IF THEY
DO NOT, THEN PRIOR TO CONSTRUCTION WITHIN THE
CONSTRUCTION BARRIER, THE CONTRACTOR IS TO
UPDATE THE WALL CONSTRUCTION TO MEET THE
REQUIREMENTS.
GENERAL NOTES:
PARTITION / WALL FIRE RATINGS
2-HR. FIRE BARRIER EXISTING 2-HR. FIRE BARRIER
NOTE: EXISTING RATED WALL SHOWN SCREENED ON PLAN. - V.I.F. WALLS MEET DESIGNATED
REQUIREMENTS & ADD OPENING & PENETRATION PROTECTIVES AS REQ'D
1-HR. SMOKE BARRIER
NON-RATED
SMOKE PARTITION
EXISTING 1-HR. SMOKE BARRIER
EXISTING NON-RATED
SMOKE PARTITION
1-HR. FIRE BARRIER EXISTING 1-HR. FIRE BARRIER
N KEY PLAN
NOT TO SCALE
SOUTH
PARKING
DECK
ENERGY
CENTER
NORTH
PARKING
DECK
9A architecture · engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERS · SURVEYORS · CONSULTANTS ·
LANDSCAPE ARCHITECTS · LAND PLANNERS
298 VETERANS DRIVE
FOWLERVILLE,
MICHIGAN 48836
(OFFICE) 517-223-3512
(FAX) 517-223-9987
211 E. Water Street, Suite 213L
Kalamazoo, MI 49007 269.216.0222
VA STATION
Defining
EXCELLENCE
in the 21st Century
HEALTH
CARE
John D. Dingell VA Medical Center
4646 John R. Street
Detroit, MI 48201
C :\U se rs
\M ic he lle
.b ur ri\ D oc um en ts
\1
5_
A _m ic he lle .b ur ri.
rv t
4/
/2
2:
:1
P
M
G-102
INFECTION CONTROL RISK
ASSESSMENT (ICRA) PLANS
RENOVATE URGENT CARE AND
REGISTRATION
DETROIT, MI
553-19-104
25MAR2022 Checker Author
100% BID DOCUMENTS190075
1/16" = 1'-0"
ICRA PLAN - LOWER LEVEL - PARTIAL ZONE 7
1/16" = 1'-0"
ICRA PLAN - LOWER LEVEL INTERSTITIAL - PARTIAL ZONE 7
INFECTION CONTROL RISK MITIGATION RECOMMENDATIONS MATRIX OF PRECAUTIONS
FOR CONSTRUCTION AND RENOVATION
TYPE OF CONSTRUCTION / PROJECT ACTIVITY TABLE
INSPECTION AND NON-INVASIVE ACTIVITIES
INCLUDES, BUT IS NOT LIMITED TO:
- REMOVAL OF CEILING TILES FOR VISUAL INSPECTION LIMITED TO 20 LN FT TILE PER 160 SQ. FT. SPACE.
- PAINTING (BUT NOT SANDING)
- WALLCOVERING, ELECTRICAL TRIM WORK, MINOR PLUMBING, AND ACTIVITIES WHICH NO NOT GENERATE DUST OR REQUIRE CUTTING OF WALLS OR ACCESS TO CEILINGS OTHER THAN FOR VISUAL INSPECTION
- PATCHING WALLS - NOT EXCEEDING 8 SQ FT
TYPE
A
SMALL SCALE, SHORT DURATION ACTIVITIES WHICH CREATE MINIMAL DUST
INCLUDES, BUT IS NOT LIMITED TO:
- INSTALLATION OF TELEPHONE AND COMPUTER CABLING
- ACCESS TO CHASE SPACES
- CUTTING OF WALLS OR CEILING WHERE DUST MIGRATION CAN BE CONTROLLED
- PATCHING WALLS - EXCEEDING 8 SQ FT
TYPE
B
WORK THAT GENERATES A MODERATE TO HIGH LEVEL OF DUST OR REQUIRES DEMOLITION OR REMOVAL OF ANY
FIXED BUILDING COMPONENTS AND ASSEMBLIES OR NEW CONSTRUCTION
INCLUDES, BUT IS NOT LIMITED TO:
- SANDING OF WALLS FOR PAINTING OR WALL COVERING EXCEEDING 32 SQ. FT., OR VACANT AREAS
- REMOVAL OF FLOOR COVERINGS, CEILING TILES AND CASEWORK
- NEW WALL CONSTRUCTION
- UNCONTAINED DUCT, HVAC OR ELECTRICAL WORK ABOVE CEILINGS
- MAJOR CABLING ACTIVITIES
- ANY OTHER PROJECT WHERE HIGH LEVELS OR DUST ARE GENERATED
TYPE
C
MAJOR DEMOLITION AND CONSTRUCTION PROJECTS
INCLUDES, BUT IS NOT LIMITED TO:
- ACTIVITIES THAT REQUIRE CONSECUTIVE WORK SHIFTS
- REQUIRES HEAVY DEMOLITION OR REMOVAL OF A COMPLETE CABLING SYSTEM
- NEW CONSTRUCTION
TYPE
D
PATIENT RISK GROUP TABLE
- ADMINISTRATIVE OFFICES
- PUBLIC CORRIDORS
- ELEVATORS
- DAY ROOMS
- CANTEEN RETAIL STORE
- VACANT WARDS OR VACANT
ICU'S ETC.
GROUP 1
LOW RISK
- OUTPATIENT, URGENT CARE &
PRIMARY CARE CLINICS
- LABORATORY
- CARDIOLOGY
- ECHOCARDIOGRAPHY
- ENDOSCOPY
- FOOD SERVICES
- INTERIM CARE & MEDICAL
UNITS
- NUCLEAR MEDICINE
- PHARMACY
- PHYSICAL THERAPY
- RADIOLOGY & NUCLEAR
MEDICINE
- RESPIRATORY THERAPY
GROUP 2
MEDIUM RISK
- CCU
- EMERGENCY ROOM
- LABORATORY
- OUTPATIENT SURGERY
- PHARMACY
- POST ANESTHESIA CARE UNIT
- SURGICAL UNITS
GROUP 3
HIGH RISK
- ANY AREA CARING FOR
IMMUNICOMPROMISED
PATIENTS
- SPD STORAGE / STERILIZATION
- INTENSIVE CARE UNITS
- TB NEGATIVE PRESSURE
ISOLATION ROOMS
- OPERATING ROOM
GROUP 4
HIGHEST RISK
INFECTION CONTROL MATRIX - CLASS OF PRECAUTIONS:
CONSTRUCTION PROJECT BY PATIENT RISK
PATIENT RISK GROUP
CONSTRUCTION PROJECT TYPE
TYPE A
LOW RISK GROUP 1
MEDIUM RISK GROUP 2
HIGH RISK GROUP 3
HIGHEST RISK GROUP 4
TYPE B TYPE C TYPE D
I II II III / IV
I II II IV
I II III / IV IV
II III / IV III / IV IV
NOTE: INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY
AND RISK LEVEL INDICATE THAT CLASS III OR IV CONTROL PROCEDURES ARE NECESSARY
IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE FOLLOWING INFECTION
CONTROL PRECAUTIONS DEPENDING UPON
THE AREA CLASS DESIGNATION
DURING CONSTRUCTION PROJECT
1. EXECUTE WORK BY METHODS TO MINIMIZE RAISING
DUST FROM CONSTRUCTION OPERATIONS.
2. IMMEDIATELY REPLACE A CEILING TILE DISPLACED
FOR VISUAL INSPECTIONS.
C L
A S
S I
UPON COMPLETION OF PROJECT
1. PROVIDE ACTIVE MEANS TO PREVENT AIRBORNE DUST FROM
DISPERSING INTO ATMOSPHERE.
2. WATER MIST WORK SURFACES TO CONTROL DUST WHILE
CUTTING.
3. SEAL UNUSED DOORS WITH DUCT TAPE.
4. BLOCK OFF AND SEAL AIR VENTS.
5. PLACE DUST MAT AT ENTRANCE AND EXIT OF WORK AREA.
6. REMOVE OR ISOLATE HVAC SYSTEM IN AREAS WHERE WORK
IS BEING PERFORMED.
C L
A S
S I
I
1. WIPE WORK SURFACES WITH DISINFECTANT.
2. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN
TIGHTLY COVERED CONTAINERS.
3. WIPE WORK SURFACES WITH DISINFECTANT, WET MOP AND /
OR VACUUM WITH HEPA VACUUM BEFORE LEAVING WORK
AREA.
4. REMOVE ISOLATION OF HVAC.
1. REMOVE OR ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS
BEING DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM.
2. COMPLETE ALL CRITICAL BARRIERS, I.E., SHEETROCK,
PLYWOOD, PLASTIC, TO SEAL AREA FROM NON-WORK AREA OR
IMPLEMENT CONTROL CUBE METHOD (CART WITH PLASTIC
COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA
VACUUM FOR VACUUMING PRIOR TO EXIT) BEFORE
CONSTRUCTION BEGINS.
3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE
UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS.
4. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN
TIGHTLY COVERED CONTAINERS.
5. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE
COVERING UNLESS SOLID LID.
C L
A S
S I
II
1. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL
COMPLETED PROJECT IS INSPECTED BY THE ENVIRONMENTAL
HEALTH AND SAFETY AND INFECTION CONTROL AND
THOROUGHLY CLEANED BY ENVIRONMENTAL SANITATION
SECTION.
2. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE
SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH
CONSTRUCTION.
3. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS.
4. WET MOP AREA WITH DISINFECTANT.
5. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE
WORK IS BEING PERFORMED.
1. OBTAIN INFECTION CONTROL PERMIT BEFORE
CONSTRUCTION BEGINS.
2. ISOLATE HVAC SYSTEMS IN AREA WHERE WORK IS BEING
DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM.
3. COMPLETE ALL CRITICAL BARRIERS OR IMPLEMENT CONTROL
CUBE METHOD BEFORE CONSTRUCTION BEGINS.
4. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE
UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS.
5. SEAL HOLES, PIPES, CONDUITS AND PUNCTURES
APPROPRIATELY.
6. CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO
PASS THROUGH THIS ROOM SO THEY CAN BE VACUUMED USING
A HEPA VACUUM CLEANER BEFORE LEAVING WORK SITE OR
THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE
REMOVED EACH TIME THEY LEAVE THE WORK SITE.
7. ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO
WEAR SHOE COVERS.
C L
A S
S
IV
1. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL
COMPLETED PROJECT IS THOROUGHLY CLEANED BY
ENVIRONMENTAL MANAGEMENT.
2. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS.
3. WET MOP AREA WITH DISINFECTANT.
4. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE
SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH
CONSTRUCTION.
5. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN
TIGHTLY COVERED CONTAINERS.
6. COVER TRANSPORT RECEPTACLES OR CARTS, TAPE
COVERING.
7. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE
WORK IS BEING PERFORMED.
1. VA PREFERS THE USE OF HARD WALL PARTITIONS OVER
THE USE OF PLASTIC SHEETING FOR SEPARATION
BETWEEN CONSTRUCTION AND EXISTING SPACES TO
REMAIN FUNCTIONING. CONTRACTOR TO SUBMIT
PROPOSED PLAN FOR TEMPORARY CONSTRUCTION
PARTITION LOCATIONS FOR COR APPROVAL. TEMPORARY
PARTITION LOCATIONS SHOWN HERE ARE RECOMMENDED
LOCATIONS BASED ON WORK NEEDING TO BE COMPLETED,
BUT DOES NOT CONSTITUTE FINAL LOCATIONS OR
QUANTITIES.
2. CONTRACTOR TO VERIFY IF EXISTING WALLS CALLED OUT
TO BE 1 HR FIRE RATED CONSTRUCTION BARRIERS MEET
THE REQUIREMENTS OF A 1 HR FIRE RATED WALL. IF THEY
DO NOT, THEN PRIOR TO CONSTRUCTION WITHIN THE
CONSTRUCTION BARRIER, THE CONTRACTOR IS TO
UPDATE THE WALL CONSTRUCTION TO MEET THE
REQUIREMENTS.
GENERAL NOTES:
E
F
G
H
J
J.1
G.3
5.6
F.2
F.8
5.2
5.4
TEMPORARY CONSTRUCTION PARTITION,
DO NOT MECHANICALLY FASTEN
PARTITION TO EXISTING FINISHED FLOOR
TEMPORARY CONSTRUCTION PARTITION,
DO NOT MECHANICALLY FASTEN
PARTITION TO EXISTING FINISHED FLOOR
TEMPORARY CONSTRUCTION
PARTITION, DO NOT MECHANICALLY
FASTEN PARTITION TO EXISTING
FINISHED FLOOR
COMPLETE DOOR
INSTALLATION AND
WALL INFILL WORK IN
THIS AREA FIRST
OUTPATIENT CLINIC
PATIENT RISK GROUP 2
EMERGENCY DEPARTMENT
PATIENT RISK GROUP 3
PROVIDE ADHESIVE
WALK-OFF MATS, TYP.
PROVIDE TEMPORARY PROTECTIVE
PLASTIC BARRIER WITH ZIPPERED
ENTRY FROM FLOOR TO THE
BOTTOM OF THE CEILING
PROVIDE TEMPORARY PROTECTIVE
PLASTIC BARRIER WITH ZIPPERED
ENTRY FROM FLOOR UP TO 12' THEN
RETURN BACK TO WALL TO ENCLOSE
ENTRANCE TO CONSTRUCTION.
TEMPORARY CONSTRUCTION PARTITION, DO
NOT MECHANICALLY FASTEN PARTITION TO
EXISTING FINISHED FLOOR. THIS
CONSTRUCTION PARTITION TO BE IN PLACE
FOR THE SHORTEST DURATION OF TIME
POSSIBLE DURING CONSTRUCTION
ONE HOUR FIRE RATED CONSTRUCTION
BARRIER
TEMPORARY REMOVAL OF GLASS AND FRAMING
SYSTEM FOR EMERGENCY DEPARTMENT
ACCESS DURING CONSTRUCTION.
CONTRACTOR TO REMOVE (2) TWO BAYS
WORTH TO PROVIDE AN OPENING LARGE
ENOUGH FOR HOSPITAL STRETCHERS TO PASS.
MODIFY SYSTEM AS REQ'D TO PROVIDE A
FINISHED APPEARANCE
ONE HOUR FIRE RATED
CONSTRUCTION BARRIER
NIC
TEMPORARY CONSTRUCTION ACCESS
DOOR
TEMPORARY CONSTRUCTION ACCESS
DOOR
TEMPORARY CONSTRUCTION PARTITION,
DO NOT MECHANICALLY FASTEN
PARTITION TO EXISTING FINISHED FLOOR
TEMPORARY CONSTRUCTION ACCESS
DOOR
COMPLETE NEW WALL CONSTRUCTION
AND INFILL NEW DOOR OPENING WITH
TEMPORARY CONSTRUCTION, ADD NEW
DOOR AT END OF CONSTRUCTION
PROVIDE ADHESIVE
WALK-OFF MATS, TYP.
PROVIDE TEMPORARY PROTECTIVE
PLASTIC BARRIER WITH ZIPPERED
ENTRY FROM FLOOR TO THE
BOTTOM OF THE CEILING
PROVIDE ADHESIVE
WALK-OFF MATS, TYP.
PROVIDE TEMPORARY PROTECTIVE
PLASTIC BARRIER WITH ZIPPERED
ENTRY FROM FLOOR TO THE
BOTTOM OF THE CEILING
G-103
TEMPORARY CONSTRUCTION ACCESS
DOOR
CEILING HEIGHT INCREASES IN THIS
AREA, TEMPORARY WALL CONSTRUCTION
TO FOLLOW ELEVATION CHANGE
E
F
G
H
J
J.1
G.3
5.6
F.2
F.8
PROVIDE ADHESIVE
WALK-OFF MATS, TYP.
NIC
PARTITION / WALL FIRE RATINGS
2-HR. FIRE BARRIER EXISTING 2-HR. FIRE BARRIER
NOTE: EXISTING RATED WALL SHOWN SCREENED ON PLAN. - V.I.F. WALLS MEET DESIGNATED
REQUIREMENTS & ADD OPENING & PENETRATION PROTECTIVES AS REQ'D
1-HR. SMOKE BARRIER
NON-RATED
SMOKE PARTITION
EXISTING 1-HR. SMOKE BARRIER
EXISTING NON-RATED
SMOKE PARTITION
1-HR. FIRE BARRIER EXISTING 1-HR. FIRE BARRIER
TEMPORARY REMOVAL OF GLASS AND
FRAMING SYSTEM FOR EMERGENCY
DEPARTMENT ACCESS DURING
CONSTRUCTION. CONTRACTOR TO
REMOVE (2) TWO BAYS WORTH TO PROVIDE
AN OPENING LARGE ENOUGH FOR
HOSPITAL STRETCHERS TO PASS.
MODIFY SYSTEM AS REQ'D TO PROVIDE A
FINISHED APPEARANCE ON BOTH FRAME
SYSTEM TO REMAIN AND FINISHED FLOOR
EXISTING STOREFRONT SYSTEM TO REMAIN
TYPICAL TEMPORARY CONSTRUCTION
PARTITION
UNDERSIDE OF EXISTING
DECK
1 HR RATED TEMPORARY
PARTITION. HI-IMPACT 5/8" GYP.
BOARD ON 3 5/8" METAL STUDS.
FINISH OCCUPIED SIDE PER
ROOM FINISH SCHEDULE
PLASTER TAPE ALL GYP. BD.
JOINTS. SECURE ALL TAPE
WITH RAM-TACK HIGH TACK
SPRAY OR EQUAL.
OCCUPIED SIDERENOVATION SIDE
2 1/2" DEEP SLOTTED
METAL DEFLECTION
TRACK FASTENED TO
DECK @ 2'-0" O.C.
COMPRESSIBLE
INSULATION
SEAL PERIMETER
COMPRESSIBLE
INSULATION
SEAL PERIMETER
DO NOT MECHANICALLY FASTEN
BOTTOM TRACK TO FLOOR
N KEY PLAN
NOT TO SCALE
SOUTH
PARKING
DECK
ENERGY
CENTER
NORTH
PARKING
DECK
7A
7B
9A architecture · engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERS · SURVEYORS · CONSULTANTS ·
LANDSCAPE ARCHITECTS · LAND PLANNERS
298 VETERANS DRIVE
FOWLERVILLE,
MICHIGAN 48836
(OFFICE) 517-223-3512
(FAX) 517-223-9987
211 E. Water Street, Suite 213L
Kalamazoo, MI 49007 269.216.0222
VA STATION
Defining
EXCELLENCE
in the 21st Century
HEALTH
CARE
John D. Dingell VA Medical Center
4646 John R. Street
Detroit, MI 48201
C :\U se rs
\M ic he lle
.b ur ri\ D oc um en ts
\1
5_
A _m ic he lle .b ur ri.
rv t
4/
/2
2:
:1
P
M
G-103
INFECTION CONTROL RISK
ASSESSMENT (ICRA) PLANS
RENOVATE URGENT CARE AND
REGISTRATION
DETROIT, MI
553-19-104
25MAR2022 Checker Author
100% BID DOCUMENTS190075
1/16" = 1'-0"
ICRA PLAN - FIRST LEVEL - PARTIAL ZONE 7
1/16" = 1'-0"
ICRA PLAN - FIRST LEVEL INTERSTITIAL - PARTIAL ZONE 7
Revisions: Date:
3/8" = 1'-0"G-103
3 TEMPORARY CONSTRUCTION ACCESS
CONCRETE:
1. ALL CONCRETE WORK TO BE PERFORMED IN CONFORMANCE WITH THE MOST RECENT
EDITION OF ACI 301 & ACI 318 CODE REQUIREMENTS AND DETAILING STANDARDS.
2. ALL CONCRETE SHALL DEVELOP THE FOLLOWING COMPRESSIVE STRENGTHS AT
28 DAYS (F`c) AS NOTED IN SPECIFICATIONS.
3. ALL REINFORCING BARS, DOWELS, ANCHOR BOLTS AND OTHER INSERTS SHALL BE
SECURED IN POSITION PRIOR TO PLACING OF THE CONCRETE.
4. ALL HORIZONTAL BARS IN CONCRETE WALLS AND GRADE BEAMS SHALL BE
CONTINUOUS AND BENT AT ALL CORNERS AND INTERSECTIONS. PRE-BENT "CORNER"
BARS SUBSTITUTED FOR CONTINUOUS BENT BARS SHALL BE OF SAME SPACING AS
HORIZONTAL BARS AND SHALL BE OF SUFFICIENT LENGTH TO PROVIDE REQUIRED
LAP SPLICE LENGTHS.
5. DETAILING BENDING AND PLACING OF REINFORCING STEEL SHALL BE IN ACCORDANCE
WITH THE MOST RECENT EDITION OF THE ACI CODE.
6. ALL CONCRETE FORMWORK SHALL BE ADEQUATELY TIED TOGETHER AND BRACED TO
FORM TRUE LINES, SQUARE CORNERS, AND PLUMB WALLS.
7. NO CONCRETE SHALL BE POURED SUBJECT TO FREEZING CONDITIONS, OR ON FROZEN
GROUND.
8. REFER TO ARCHITECTURAL DRAWINGS FOR MOLDS, GROOVES, ORNAMENTS, OR
ACCESSORIES REQUIRED TO BE CAST INTO CONCRETE, AND FOR LOCATIONS OF FLOOR
FINISHES AND SLAB DEPRESSIONS.
10. LOCATE ALL SLEEVES, OPENINGS, EMBEDDED ITEMS, ETC. WHICH ARE INDICATED
ON DESIGN DRAWINGS. CHECK WITH OTHER TRADES TO VERIFY THAT ALL SLEEVES,
OPENINGS, AND EMBEDDED ITEMS ARE IN PLACE AND LOCATED CORRECTLY PRIOR
TO PLACEMENT OF CONCRETE.
11. PIPE MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES, BUT SHALL NOT BE
EMBEDDED THEREIN. SLEEVES SHALL BE WRAPPED WITH EXPANSION JOINT FILLER
MATERIAL TO ALLOW CONCRETE TO CURE WITHOUT RESTRAINT. PIPES OR CONDUITS
WITH DIAMETER EXCEEDING ONE THIRD THE SLAB OR WALL THICKNESS SHALL NOT BE IN
STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED AS SUCH. SEE MECHANICAL
AND/OR ELECTRICAL DRAWINGS FOR LOCATIONS OF SLEEVES, ACCESSORIES, ETC.
12. THE SURFACE OF ALL CONSTRUCTION JOINTS SHALL BE CLEANED TO REMOVE ALL
DUST, CHIPS, OR OTHER FOREIGN MATTER PRIOR TO THE PLACEMENT OF ADJACENT
CONCRETE.
13. SLAB CONTROL JOINTS SHALL BE INSTALLED WITH JOINT FORMERS WHEN THE SLAB
IS POURED , OR SAWCUT AS SOON AS THE CONCRETE WILL ALLOW WITHOUT DAMAGE.
14. ALL EMBEDDED ITEMS SHALL BE PLACED IN THE FORMWORK PRIOR TO PLACING
CONCRETE. DRILLING AND GROUTING IS ACCEPTABLE SUBJECT TO ENGINEER
APPROVAL.
15. CONCRETE WALLS MAY BE BACKFILLED TO TWO-THIRDS THE WALL HEIGHT ONCE 75%
OF THE 28 DAY COMPRESSIVE DESIGN STRENGTH HAS BEEN ACHIEVED. WALLS WITH
TOP SLABS MAY BE BACKFILLED TO ONE-HALF OF THE WALL HEIGHT PRIOR TO CASTING
THE TOP SLAB.
REINFORCING STEEL:
1. ALL REINFORCING STEEL SHALL BE HIGH STRENGTH DEFORMED BARS, GRADE 60,
ASTM A615, WITH 60,000 PSI MINIMUM YIELD STRENGTH, UNLESS NOTED OTHERWISE.
2. REINFORCEMENT PROTECTION: (U.N.O.)
A. CONCRETE POURED AGAINST EARTH = 3"
B. CONCRETE POURED IN FORMS BUT EXPOSED = 2"
TO WEATHER, EARTH OR LIQUID
C. SLABS AND WALLS NOT EXPOSED TO WEATHER OR EARTH = 1 1/2"
D. BEAMS, GIRDERS, AND COLUMNS NOT EXPOSED TO
WEATHER, OR IN CONTACT WITH EARTH = 1 1/2"
3. WELDING OF REINFORCING BARS IS NOT PERMITTED, UNLESS NOTED OTHERWISE.
MASONRY:
1. CONCRETE MASONRY UNITS (CMU) ARE TO CONFORM TO ASTM C-90.
2. SEE SPECIFICATIONS FOR UNIT WEIGHT AND STRENGTH.
3. ALL MASONRY REINFORCING SHALL BE PLACED AND SUPPORTED IN CONFORMANCE
WITH THE PROVISIONS OF THE LATEST EDITION OF ACI 530.1/ASCE-6/TMS 602.
4. ALL VERTICAL REINFORCING STEEL IN CMU WALLS SHALL BE CONTINUOUS FROM
THE FOOTING TO THE BOND BEAM, AND TERMINATED IN END HOOKS. WHERE BOND
BEAMS ARE NOT AT THE TOP OF A WALL, REINFORCING SHALL BE CONTINUOUS
THROUGH THE BOND BEAM TO TOP WALL.
5. ALL REINFORCING BARS MARKED "CONTINUOUS" SHALL BE SPLICED A MINIMUM OF 50
BAR DIAMETERS, BUT NOT LESS THAN 24 INCHES.
6. ALL MASONRY WORK BELOW GRADE SHALL HAVE CORES GROUTED SOLID WITH GROUT
CONFORMING TO ASTM C176. BELOW GRADE MASONRY SHALL USE TYPE M OR S
MORTAR.
7. SEE LINTEL SCHEDULE FOR LINTEL SIZES. ALL STEEL LINTELS IN EXTERIOR WALLS
SHALL BE HOT-DIP GALVANIZED, UNLESS NOTED OTHERWISE.
8. MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM TO ALL REQUIREMENTS
OF "SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 510.3/ASCE-6/TMS-602)," EXCEPT
AS MODIFIED BY THE REQUIREMENTS OF THESE CONTRACT DRAWINGS.
9. CONTROL JOINTS SHALL BE INSTALLED AT LOCATIONS SHOWN ON THESE DRAWINGS. IN
AREAS NOT NOTED ON DRAWINGS, A MINIMUM PLACEMENT OF ONE SIDE ABOVE ALL
OPENINGS 6'-0" WIDE OR LESS, AND AT BOTH SIDES OF ALL OTHER OPENINGS, OR AT
20'-0" O.C.MAX.
STRUCTURAL DESIGN INFORMATION:
DESIGN DATA BASED ON ASCE 7-10
RISK CATEGORY: IV
1. SNOW LOAD:
SNOW EXPOSURE FACTOR (Ce) 1.0 THERMAL FACTOR (Ct) 1.0 SNOW IMPORTANCE FACTOR (Is) 1.00 GROUND SNOW LOAD (Pg) 20 PSF SLOPED ROOF FACTOR (Cs) 1.0
2. EXISTING FLOOR LIVE LOAD:
INTERSTITIAL FLOORS 25 PSF
MAIN FLOORS 150 PSF
4. WIND LOADS:
BASIC WIND SPEED 120 MPH
WIND IMPORTANCE FACTOR (Iw) 1.00
WIND EXPOSURE CATEGORY 'C'
5. SEISMIC LOADS:
SEISMIC IMPORTANCE FACTOR (Ie) 1.50
SITE CLASS 'D'
SPECTRAL RESPONSE COEFFICIENTS:
SS = 0.096 SDS = 0.103
S1 = 0.047 SD1 = 0.075
SEISMIC DESIGN CATEGORY 'C'
STRUCTURAL STEEL:
1. STRUCTURAL AND MISC. STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN
ACCORDANCE WITH THE MOST RECENT EDITION OF AISC STEEL CONSTRUCTION
MANUAL AND CODE OF STANDARD PRACTICE. STEEL JOISTS SHALL CONFORM TO THE
MOST RECENT EDITION OF STANDARD SPECIFICATIONS OF THE STEEL JOIST INSTITUTE.
METAL DECK SHALL CONFORM TO THE MOST RECENT EDITION OF THE STANDARD
SPECIFICATION OF THE STEEL DECK INSTITUTE.
3. USE BOLTED CONNECTIONS AS SPECIFIED IN FRAMING DETAIL FOR SIZE AND NUMBER
OF BOLTS AND WELDS FOR ALL STRUCTURAL STEEL CONNECTIONS. ALL BOLTED
CONNECTIONS SHALL BE STANDARD ROUND HOLES (UNLESS NOTED OTHERWISE).
IF DETAIL IS NOT PROVIDED:
ALL BOLTED CONNECTIONS SHALL BE BEARING TYPE "N", 3/4" DIA. BOLTS (BRG. TYPE)
OR WELDED EQUIVALENT, UNLESS OTHERWISE NOTED. SELECT CONNECTIONS TO
SUPPORT ONE HALF THE TOTAL LOAD CAPACITY FOR EACH GIVEN BEAM AND SPAN.
THE EFFECT OF CONCENTRATED LOADS SHALL ALSO BE CONSIDERED.
4. CONNECTIONS MADE WITH HIGH STRENGTH STEEL BOLTS SHALL CONFORM IN ALL
RESPECTS TO THE CURRENT SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM
A325 BOLTS AS ENDORSED BY THE AISC. NO PAINT ON FAYING SURFACES.
5. WELDING SHALL BE DONE IN ACCORDANCE WITH THE "AMERICAN WELDING SOCIETY"
(AWS) D1.1, USING E70 ELECTRODES. WELDING SHALL BE PERFORMED BY AN
APPROVED CERTIFIED WELDER.
6. NO CHANGES SHALL BE MADE IN THE STEEL STRUCTURE NOR ANY MATERIAL CUT IN THE
FIELD (UNLESS NOTED AS "FIELD CUT OR TRIM" ON DRAWINGS), WITHOUT THE
WRITTEN PERMISSION OF THE ENGINEER.
7. NO CUTTING, BURNING, OR HOLES OTHER THAN THOSE SPECIFICALLY DETAILED SHALL
BE ALLOWED THROUGH STRUCTURAL STEEL MEMBERS WITHOUT THE PRIOR CONSENT
OF THE ENGINEER. BOLT HOLES SHALL CONFORM WITH THE GOVERNING AISC
SPECIFICATION, AND SHALL BE STANDARD HOLES UNLESS NOTED OTHERWISE.
8. THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN
THE DESIGN AND ACTUAL CONDITIONS NOTED IN THE FIELD.
9. CONTRACTOR SHALL PROVIDE NECESSARY LABOR, MATERIAL, AND EQUIPMENT TO
ERECT ALL MISCELLANEOUS IRON AND STEEL AS DETAILED ON THESE DRAWINGS.
10. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION.
11. UNLESS OTHERWISE INDICATED, ROOF OPENINGS MADE IN EXISTING ROOF STRUCTURE
SHALL BE SUPPORTED ON ALL EDGES BY L4x4x1/4" FOR SPANS OF 5’-0" OR LESS; AND BY
C8X11.5 FOR SPANS BETWEEN 5’-0” AND 10’-0”. SPANS EXCEEDING 10’-0” SHALL REQUIRE
SECTIONS APPROVED BY THE ENGINEER. CONNECTIONS SHALL BE WELDED IN
ACCORDANCE WITH AWS D1.1 AND AISC, OR MINIMUM 2-BOLT CONNECTIONS
ACCORDING TO AISC.
GENERAL STRUCTURAL NOTES
1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS AND CONDITIONS
AT THE JOB SITE AND TO CROSS-CHECK DETAILS AND DIMENSIONS ON THE STRUCTURAL
DRAWINGS WITH THE RELATED REQUIREMENTS ON THE ARCHITECTURAL, MECHANICAL,
ELECTRICAL, AND PLUMBING PLANS. FLOOR AND WALL OPENINGS, SLEEVES AND OTHER
ARCH., MECH., ELEC., REQUIREMENTS MUST BE COORDINATED BEFORE THE CONTRACTOR
PROCEEDS WITH CONSTRUCTION.
2. ALL ENGINEERING DESIGN, CONSTRUCTION, AND TESTING SHALL CONFORM TO THE
REQUIREMENTS OF THE MOST RECENT EDITION OF THE INTERNATIONAL BUILDING CODE.
3. ALL STRUCTURAL WORK MUST BE TEMPORARILY BRACED AND SUPPORTED UNTIL THE
STRUCTURE IS SUFFICIENTLY COMPLETED AND CAN SAFELY CARRY THE DESIGN AND
CONSTRUCTION LOADS.
4. REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN ON THE
STRUCTURAL DRAWINGS.
5. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING
DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE
ENGINEER BEFORE PROCEEDING WITH ANY WORK THAT IS INVOLVED IN THE CONFLICT.
ABBREVIATIONS
TYPE DESCRIPTION
A.B. ANCHOR BOLT
ALT. ALTERNATE
ARCH. ARCHITECTURAL
AVG. AVERAGE
AFF ABOVE FINISH FLOOR
BFF BELOW FINISH FLOOR
BLDG. BUILDING
BM. BEAM
B.O. BOTTOM OF
BRG. BEARING
C.J. CONTROL JOINT
CMU CONCRETE MASONRY UNIT
CONC. CONCRETE
CONST. JT. CONSTRUCTION JOINT
CONT. CONTINUOUS
D DEPTH
DET. DETAIL
DTL. DETAIL
DIA. DIAMETER
EA. EACH
ELEV. ELEVATION
EQ. EQUAL
E.W. EACH WAY
EXIST. EXISTING
EXST. EXISTING
E.F. EACH FACE
F.F. FINISH FLOOR
FLR. FLOOR
FND. FOUNDATION
FNDTN. FOUNDATION
FTG. FOOTING
F.S. FAR SIDE
GA. GAUGE
GALV. GALVANIZED
HDG HOT DIPPED GALVANIZED
HORIZ. HORIZONTAL
HORZ. HORIZONTAL
H.P. HIGH POINT
INSUL. INSULATION
I.F. INSIDE FACE
TYPE DESCRIPTION
L LENGTH
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
L.P. LOW POINT
MAX. MAXIMUM
MECH. MECHANICAL
MEZZ. MEZZANINE
MANUF. MANUFACTURER
MNF. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
N.S. NEAR SIDE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F OUTSIDE FACE
O.H. OVERHEAD
OHD OVERHEAD DOOR
O/O OUT TO OUT
PSF POUNDS PER SQUARE FT.
PSI POUNDS PER SQUARE IN.
R RADIUS
REINF. REINFORCING
SIM. SIMILAR
T&B TOP AND BOTTOM
T.O. TOP OF
T.O.B.L. TOP OF BRICK LEDGE
T.O.F TOP OF FOOTING
T.O.F.W. TOP OF FOUNDATION WALL
T.O.P. TOP OF PIER
T.O.S TOP OF STEEL
TRANS. TRANSVERSE
TYP. TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
VERT. VERTICAL
V.S.C VERTICAL SLOTTED CONN.
V.B.F. VERTICAL BRACED FRAME
WWF WELDED WIRE FABRIC
W WIDTH
W/ WITH
LAP CHART
BAR
SIZE
VERT. BARS
#3
#4
#5
#6
#7
#8
#9
#10
HORZ. BARS
4000 PSI CONCRETE
19"
25"
31"
38"
54"
62"
70"
79"
25"
33"
41"
49"
71"
81"
91"
102" architecture · engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERS · SURVEYORS · CONSULTANTS ·
LANDSCAPE ARCHITECTS · LAND PLANNERS
298 VETERANS DRIVE
FOWLERVILLE,
MICHIGAN 48836
(OFFICE) 517-223-3512
(FAX) 517-223-9987
211 E. Water Street, Suite 213L
Kalamazoo, MI 49007 269.216.0222
VA STATION
Defining
EXCELLENCE
in the 21st Century
HEALTH
CARE
John D. Dingell VA Medical Center
4646 John R. Street
Detroit, MI 48201
C :\U se rs
\M ic he lle
.b ur ri\ D oc um en ts
\1
5_
S _m ic he lle .b ur ri.
rv t
4/
/2
2:
:3
P
M
S-001
GENERAL NOTES AND LEGENDS RENOVATE URGENT CARE AND
REGISTRATION
DETROIT, MI
553-19-104
25MAR2022 Checker Author
100% BID DOCUMENTS190075
LOWER LEVEL NOTES
1. CONTRACTOR SHALL VERIFY DIMENSIONS WITH ARCHITECTURAL
PLANS. NOTIFY ENGINEER OF DISCREPANCIES.
2. ALL SLABS ON GRADE SHALL BEAR ON A MINIMUM OF 6" OF CLEAN
GRANULAR FILL CONSISTING OF SAND AND GRAVEL OR CRUSHED
STONE. BASE COURSE TO BE COMPACTED TO A MINIMUM OF 95%
OF MODIFIED STANDARD PROCTOR.
3. ALL FILL MATERIAL SHALL BE NON-COHESIVE SOILS, COMPACTED
TO 95% MAXIMUM DENSITY PER ASTM D1557 MODIFIED PROCTOR
METHOD. THE UPPER 6" OF SUB GRADE SHALL BE SCARIFIED,
MOISTURE CONDITIONED, AND COMPACTED PER TESTS ABOVE.
G G
H H
J J
J.1 J.1
G.3 G.3
5.8
5.88.1
8.1
ZONE 7A
ZONE 7B
Z O
N E
ZONE 7A
ZONE 7B
Z O
N E
ZONE 7B
ZONE 7
S-502
TYP.______
10" ± 6' - 10" ±
5'
0"
3'
0"
EXISTING SLAB ON GRADE
EXISTING CONCRETE PIER &
STEEL COLUMN, TYP.
SLAB-1
S-501
FLOOR SLAB SYSTEM SCHEDULE
MARK DESCRIPTION
SLAB-1
6" CONCRETE SLAB ON GRADE WITH 6x6 - W2.9xW2.9 WWF, OVER COMPACTED GRANULAR FILL AND VAPOR
RETARDER, TYP. U.N.O.
SLAB-3
4 1/2" TOTAL SLAB THICKNESS LIGHT WEIGHT CONCRETE
ON 1 1/2", 20 GA., 36" WIDE NON-COMPOSITE METAL DECK
(GRADE 50 STEEL) WITH 6x6 - W4.0xW4.0 WWF.
SLAB-2
7 1/2" TOTAL SLAB THICKNESS NORMAL WEIGHT CONCRETE
ON 3", 18 GA., 36" WIDE COMPOSITE METAL DECK (GRADE 50
STEEL) WITH 6x6 - W2.1xW2.1 WWF.
N
KEY PLAN
NOT TO SCALE
SOUTH
PARKING
DECK
ENERGY
CENTER
NORTH
PARKING
DECK
7A
7B
9A architecture · engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERS · SURVEYORS · CONSULTANTS ·
LANDSCAPE ARCHITECTS · LAND PLANNERS
298 VETERANS DRIVE
FOWLERVILLE,
MICHIGAN 48836
(OFFICE) 517-223-3512
(FAX) 517-223-9987
211 E. Water Street, Suite 213L
Kalamazoo, MI 49007 269.216.0222
VA STATION
Defining
EXCELLENCE
in the 21st Century
HEALTH
CARE
John D. Dingell VA Medical Center
4646 John R. Street
Detroit, MI 48201
C :\U se rs
\M ic he lle
.b ur ri\ D oc um en ts
\1
5_
S _m ic he lle .b ur ri.
rv t
4/
/2
2:
:3
P
M
S-110.7B
SLAB PLAN - LOWER LEVEL -
ZONE 7B
RENOVATE URGENT CARE AND
REGISTRATION
DETROIT, MI
553-19-104
25MAR2022 Checker Author
100% BID DOCUMENTS190075
1/4" = 1'-0"
SLAB PLAN - LOWER LEVEL- ZONE 7B
H
J
J.1
G.3
5.8
ZONE 7B
ZONE 7A
ZONE 7B
ZONE 7A
Z O
N E
Z O
N E
ZONE 7B
ZONE 7
S
LA
B -3
S-502
TYP.______
10" ± 6' - 10" ±
5'
0"
3'
0"
EXISTING LIGHT
WEIGHT CONCRETE
FLOOR ON METAL
DECK
EXISTING
CONCRETE
PIER & STEEL
COLUMN, TYP.
EXISTING STEEL
BEAM, TYP.
EXISTING HANGER
ROD, TYP.
S-501
INTERSTITIAL LEVEL NOTES
1. CONTRACTOR SHALL VERIFY DIMENSIONS WITH ARCHITECTURAL
PLANS. NOTIFY ENGINEER OF DISCREPANCIES.
2. SEE MECHANICAL & PLUMBING DRAWINGS TO VERIFY FLOOR
INFILL & NEW OPENING LOCATIONS.
FLOOR SLAB SYSTEM SCHEDULE
MARK DESCRIPTION
SLAB-1
6" CONCRETE SLAB ON GRADE WITH 6x6 - W2.9xW2.9 WWF, OVER COMPACTED GRANULAR FILL AND VAPOR
RETARDER, TYP. U.N.O.
SLAB-3
4 1/2" TOTAL SLAB THICKNESS LIGHT WEIGHT CONCRETE
ON 1 1/2", 20 GA., 36" WIDE NON-COMPOSITE METAL DECK
(GRADE 50 STEEL) WITH 6x6 - W4.0xW4.0 WWF.
SLAB-2
7 1/2" TOTAL SLAB THICKNESS NORMAL WEIGHT CONCRETE
ON 3", 18 GA., 36" WIDE COMPOSITE METAL DECK (GRADE 50
STEEL) WITH 6x6 - W2.1xW2.1 WWF.
N
KEY PLAN
NOT TO SCALE
SOUTH
PARKING
DECK
ENERGY
CENTER
NORTH
PARKING
DECK
7A
7B
9A architecture · engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERS · SURVEYORS · CONSULTANTS ·
LANDSCAPE ARCHITECTS · LAND PLANNERS
298 VETERANS DRIVE
FOWLERVILLE,
MICHIGAN 48836
(OFFICE) 517-223-3512
(FAX) 517-223-9987
211 E. Water Street, Suite 213L
Kalamazoo, MI 49007 269.216.0222
VA STATION
Defining
EXCELLENCE
in the 21st Century
HEALTH
CARE
John D. Dingell VA Medical Center
4646 John R. Street
Detroit, MI 48201
C :\U se rs
\M ic he lle
.b ur ri\ D oc um en ts
\1
5_
S _m ic he lle .b ur ri.
rv t
4/
/2
2:
:3
P
M
S-110.I.7B
INTERSTITIAL FRAMING PLAN -
LOWER LEVEL - ZONE 7B
RENOVATE URGENT CARE AND
REGISTRATION
DETROIT, MI
553-19-104
25MAR2022 Checker Author
100% BID DOCUMENTS190075
1/4" = 1'-0"
INTERSTITIAL FRAMING PLAN - LOWER LEVEL
E E
F F
G G
D.8 D.8
ZONE 7A
ZONE 7B
Z O
N E
ZONE 7A
ZONE 7B
Z O
N E
Z
O N
E
Z O
N E
S
LA
B -2
S-502
TYP.______
S-501
S-501
FLOOR DRAIN,
SEE NOTE 1, TYP.
± 4' - 0" ± 9' - 4 1/2"
1/
8"
REMOVE EXISTING CMU WALL
UP TO EXISTING STEEL LINTEL
ELEVATION, COORDINATE
WITH ARCHITECTURAL
DRAWINGS
EXISTING
CONCRETE FLOOR
ON METAL DECK
EXISTING STEEL
COLUMN, TYP.
EXISTING
STEEL BEAM,
TYP.
/8
± 7' - 4"
COORD. W/ ARCH PLANS
12' - 10 3/8"
M A
S O
N R
Y O
P E
N
IN
G
± 10' - 6 5/8"
COORD. W/ ARCH PLANS
13' - 3 5/8"
1'
7" 6'
/8
8' - 8"
4'
3/
8"
12' - 3 3/8"
1'
1/
2"
1/
2"
13' - 8 1/8" 10 5/8"
5'
5/
8"
1' - 8 7/8"
6' - 3 1/2"
FLOOR DRAIN,
SEE NOTE 1, TYP.
FLOOR DRAIN,
SEE NOTE 1, TYP.
FLOOR DRAIN,
SEE NOTE 1, TYP.
FLOOR DRAIN,
SEE NOTE 1, TYP.
2'
0" M
IN
. T
Y P
2' - 0" MIN. TYP.
FLOOR SLAB SYSTEM SCHEDULE
MARK DESCRIPTION
SLAB-1
6" CONCRETE SLAB ON GRADE WITH 6x6 - W2.9xW2.9 WWF, OVER COMPACTED GRANULAR FILL AND VAPOR
RETARDER, TYP. U.N.O.
SLAB-3
4 1/2" TOTAL SLAB THICKNESS LIGHT WEIGHT CONCRETE
ON 1 1/2", 20 GA., 36" WIDE NON-COMPOSITE METAL DECK
(GRADE 50 STEEL) WITH 6x6 - W4.0xW4.0 WWF.
SLAB-2
7 1/2" TOTAL SLAB THICKNESS NORMAL WEIGHT CONCRETE
ON 3", 18 GA., 36" WIDE COMPOSITE METAL DECK (GRADE 50
STEEL) WITH 6x6 - W2.1xW2.1 WWF.
FRAMING NOTES
1. FLOOR DRAINS IN EXISTING SLABS:
CUT, CHIP, OR GRIND RECESS IN SLAB TO A MAXIMUM DEPTH OF 2"
BELOW FINISHED FLOOR. INFILL SLAB CUT-OUT WITH LIGHTWEIGHT
CONCRETE OR GROUT TO MATCH EXISTING DEPTH. SLOPE SLAB
TOWARD DRAINS AT 1/4" PER FOOT. COORDINATE WITH
ARCHITECTURAL & PLUMBING DRAWINGS FOR EXACT LOCATIONS.
CONTRACTOR TO VERIFY LOCATIONS AND DIMENSIONS IN FIELD.
2. CONTRACTOR SHALL VERIFY DIMENSIONS WITH ARCHITECTURAL
PLANS. NOTIFY ENGINEER OF DISCREPANCIES.
3. SEE MECHANICAL & PLUMBING DRAWINGS TO VERIFY FLOOR INFILL
& NEW OPENING LOCATIONS
4. ALL WALLS TO BE ADEQUATELY BRACED & SHORED AS NEEDED
PRIOR TO THE START OF DEMOLITION AND DURING INSTALLATION
OF NEW LINTELS.
N
KEY PLAN
NOT TO SCALE
SOUTH
PARKING
DECK
ENERGY
CENTER
NORTH
PARKING
DECK
7A
7B
9A architecture · engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERS · SURVEYORS · CONSULTANTS ·
LANDSCAPE ARCHITECTS · LAND PLANNERS
298 VETERANS DRIVE
FOWLERVILLE,
MICHIGAN 48836
(OFFICE) 517-223-3512
(FAX) 517-223-9987
211 E. Water Street, Suite 213L
Kalamazoo, MI 49007 269.216.0222
VA STATION
Defining
EXCELLENCE
in the 21st Century
HEALTH
CARE
John D. Dingell VA Medical Center
4646 John R. Street
Detroit, MI 48201
C :\U se rs
\M ic he lle
.b ur ri\ D oc um en ts
\1
5_
S _m ic he lle .b ur ri.
rv t
4/
/2
2:
:3
P
M
S-111.7A
FRAMING PLAN - FIRST LEVEL -
ZONE 7A
RENOVATE URGENT CARE AND
REGISTRATION
DETROIT, MI
553-19-104
25MAR2022 Checker Author
100% BID DOCUMENTS190075
1/4" = 1'-0"
FRAMING PLAN - FIRST LEVEL
G G
H H
J J
J.1 J.1
G.3 G.3
5.8
ZONE 7A
ZONE 7B
Z O
N E
ZONE 7A
ZONE 7B
Z O
N E
S
LA
B -2
S-502
TYP.______
S-502
TYP.______
S-501
S-5…