Drawings - Electrical 22037.pdf
PDF 4 MB Posted
- Solicitation number
- RFQ - 171 - 230000000356
- Issued by
- Jackson County, Michigan
About this file
This document is a set of electrical drawings and specifications related to a state and local contract opportunity for the Parnall Correctional Facility Mental Health Office Remodel and Addition project in Jackson County, Michigan. The drawings provide details on the electrical demolition, lighting, power, and fire alarm system work required for the project. Key details include the installation of new light fixtures, occupancy sensors, power panels, electrical connections for HVAC equipment, and upgrades to the fire alarm system. The bid attachments must be uploaded to the SIGMA VSS system, and all questions should be directed to the architect via email. The bid submission deadline is 2:00 pm.
The contract includes pricing for the electrical work, which must comply with state and local requirements. There are no set-asides identified, and the incumbent contractor is not specified. The project is funded through state and local sources, but the specific funding amounts are not provided. The contract term and any renewal options are also not detailed in the documents.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FCPS
V
M C
VI
AV
B
C
DC
M
B
KP
SSCP
CR
SS
AS
TS
G
NCC
M P
E
A L B1 B2
S
SRS
X
X
X
CB
EMERGENCY PUSH STATION
CODE BLUE STATION
TVSS
VFD
TRANSIENT VOLTAGE SURGE SUPPRESSION
VARIABLE FREQUENCY DRIVE
GLASS BREAK
DS
DUPLEX RECEPTACLE
TEACHER STATION
ADMINISTRATION STATION
STUDENT STATION
CARD READER
CARBON MONOXIDE DETECTOR
H
DOCK LIGHT FIXTURE
CONTROL MODULE
S
TELEPHONE / DATA OUTLET
DUTY STATION
STAFF STATION
STAFF REGISTER STATION
DOME LIGHT
DUAL BED STATION
SINGLE BED STATION
BED / LIGHT INTERFACE
PENDENT INTERFACE
EMERGENCY PULL STATION
MASTER STATION
NURSE CALL CONTROLLER
NURSE CALL
ADDENDUM NOTE
PLAN NOTE
DEMOLITION NOTE
THREE PHASE MOTOR
BELL
AUDIO / VIDEO INPUT
VIDEO INPUT
WALL MOUNTED SPEAKER / CLOCK COMBO
WALL MOUNTED SPEAKERS
DUAL FACE CLOCK
CCTV CONTROL PANELCCTV
SECURITY SYSTEM CONTROL PANEL
KEY PAD
BEAM DETECTOR
MOTION DETECTOR
DOOR CONTACT
CAMERA
MONITOR MODULE
FIRE CONTROL POWER SUPPLY
VISUAL ONLY UNIT
ELECTRICAL SYMBOLS LEGEND
DH
V
S
C
M
I
J
SINGLE RECEPTACLE (120 VOLT)
EMERGENCY RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
SINGLE FACE CLOCK
FLUSH FLOOR BOX
SURFACE FLOOR BOX
SPECIAL EQUIPMENT RECEPTACLE
TELEPHONE OUTLET
DATA OUTLET
POWER POLE
JUNCTION BOX
WALL JUNCTION BOX
PULL (JUNCTION) BOX
UNDERFLOOR JUNCTION BOX
OUTLETS
LIGHT FIXTURE
STRIP FIXTURE
IN-GRADE LIGHT FIXTURE
SPOTLIGHT (number of heads shown) EXIT SIGN (face & direction as shown)
WALL MOUNT LIGHT FIXTURE
CEILING LIGHT FIXTURE
TRACK & FIXTURE
STREET TYPE POLE FIXTURE
POLE MOUNTED LIGHT FIXTURE
EXTERIOR WALL MOUNT LIGHT FIXTURE
WALLPACK LIGHT FIXTURE
SPECIAL PURPOSE LIGHT FIXTURE
HIGH BAY LIGHT FIXTURE
EMERGENCY EGRESS LIGHT FIXTURE
(number of heads shown)
EMERGENCY LIGHT FIXTURE
FIXTURES
SWITCHES
SINGLE-POLE SWITCH
DIMMER SWITCH
TIME SWITCH
KEY SWITCH
MANUAL MOTOR SWITCH
THERMAL OVERLOAD SWITCH
SWITCH WITH PILOT LIGHT
FOUR-WAY SWITCH
THREE-WAY SWITCH
CIRCUITRY and RACEWAYS
UNDERFLOOR DUCT
BUS DUCT
PLUGMOLD AS SPECIFIED
WIREMOLD AS SPECIFIED
FLEXIBLE PIGTAILS/CONNECTIONS
"CONDUIT RUN CONTINUES" INDICATION
END OF CONDUIT RUN, CAP AND STAKE
END OF CONDUIT RUN
HOME RUN (with circuit numbers)
CONDUIT STUB DOWN
CONDUIT STUB UP
CONDUIT INSTALLED
CONDUIT INSTALLED
MECHANICAL
ELECTRIC WATER HEATER
ELECTRIC UNIT HEATER
PIPE TRACE HEATER
RESISTANCE HEATER, KW SHOWN
SINGLE PHASE MOTOR
SOUND and SIGNAL
INTERCOM OUTLET
MICROPHONE OUTLET
TELEVISION OUTLET
CHIME
BUZZER
VOLUME CONTROL
SPEAKER
SERVICE and EQUIPMENT
THERMOSTAT
CAPACITOR
ENCLOSED CIRCUIT BREAKER
TRANSFER SWITCH
WIREWAY
GROUND CONNECTION PER N.E.C.
TELEPHONE TERMINAL BOARD
GENERATOR, KW SHOWN
CURRENT TRANSFORMERS
UTILITY METER, AS REQUIRED
WEATHERHEAD
PANELBOARD, FLUSH MOUNTED
PANELBOARD, SURFACE MOUNTED
COMB. STARTER
MAGNETIC STARTER
DISCONNECT SWITCH
TRANSFORMER
CONTROL
xxVA connection by x/C) IRRIGATION CONTROLLER (120 volt
LIGHTING CONTACTOR
CONTROL TRANSFORMER
buttons indicated) PUSHBUTTON STATION (number of TIME CLOCK (24 hour U.O.N.)
PHOTOCELL (voltage as required)
HUMIDISTAT
FIRE ALARM
TAMPER SWITCH (furnished by FP/C) FLOW SWITCH (furnished by FP/C)
FIREFIGHTER COMMUNICATION JACK
MAGNETIC DOOR HOLDER
REMOTE INDICATING LIGHT, CLG. MTD.
REMOTE INDICATING LIGHT, WALL MTD.
END OF LINE DEVICE
ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
PULL STATION
SPEAKER & LIGHT
SPEAKER
HORN
DUCT SMOKE DETECTOR
HEAT DETECTOR
SMOKE DETECTOR
HORN & LIGHT
DESIGNATIONS
(by E.C.)
(by others)
TT
FACP
ANN
EOL
G
WW
PC
CT
TS
T
H
TC
IC
F
FC
F
T
1,3
OR
PM
WM
BD
UFD
B
F S
J
J
D
WH
PP
J
SWITCH STYLE OCCUPANCY SENSOROC
DIGITAL TIME SWITCH
POWER PACK
DUAL TECHNOLOGY SENSOR - 360° - 500 SQ FT
DUAL TECHNOLOGY SENSOR - 360° - 1000 SQ FT
ULTRASONIC SENSOR - 360° - 2 CIRCUIT
OCCUPANCY SENSOR / PHOTOCELL
WALL MOUNT DUAL TECHNOLOGY SENSOR
OS5
OS4
T
OS2
OS3
OS1
PP
DUCT SMOKE DETECTORF/S
CEILING MOUNTED WIFI
DIGITAL EQUIPMENT METER, AS REQUIRED
POLE
PUMP
PANEL
P
PNL
PVC
PRV-
P-
PB
POLY VINYL CLORIDE
POWER ROOF VENTILATOR
PULL BOX
GENERAL CONTRACTOR
GROUND
HUMIDIFIERH-
GND
GFI
GC
GROUND FAULT INTERUPTER
ABBREVIATIONS LEGEND
POWER
SWITCH
RECEPT
SF-
SWBD
TCC
SPEC
SW
RGC
RTU-
PWR
VOLTS
WATTS
UF
V
W
UL
VL
UNO
UH-
TS
TYP
TR
ROOF TOP UNIT
RECEPTACLE
SWITCHBOARD
UNDER FLOOR
SPECIFICATIONS
RIGID GALVANIZED STEEL CONDUIT
UNLESS NOTED OTHERWISE
UNDERWRITERS' LABORATORIES, INC.
TAMPER PROOF RECEPTACLE
TAMPER PROOF SWITCH
TEMPERATURE CONTROL CONTRACTOR
VERIFY LOCATION WITH OWNER
TYPICAL
UNIT HEATER
SUPPLY FAN
WITH
WITHOUT
W/
XFMR
W/O
WP
TRANSFORMER
WEATHER PROOF
HOUR
LIGHT
JUNCTION BOX
LIGHT CONTROL
ISOLATED GROUND
HORSEPOWER
MINIMUM
MOUNT
MAKE-UP AIR UNIT
MOTOR CONTROL CENTER
MAIN LUG ONLY
MOUNTED
MOUNTING
MAXIMUM
LIGHTING
LT FLEX
MTD
MUAU-
MTG
MLO
MIN
MT
MC
MAX
MCC
LTG
IG
LC
LT
IMC
JB
HR
HVAC
HOA
HP
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
NIGHT LIGHTNL
NTS
NO
NIC
NC
HAND-OFF-AUTO SELECTOR SWITCH
HEATING/VENTILATING/AIR CONDITIONING
INTERMEDIATE METAL CONDUIT
LIQUID TIGHT FLEXIBLE METAL CONDUIT
MECHANICAL CONTRACTOR
HID HIGH INTENSITY DISCHARGE
A
AC
AFF
ACU-
AHJ
AHU-
AS
B-
BC
AIC
ATS
BLDG
CHLR-
CND (C)
CKT BKR
CKT
CUH-
CU-
DISC
DFU-
EF-
EC
DWH-
EBB-
DWG
CT-
EXIST (E)
EWC
FLEX
FLA
FLR
FSES
FLUOR
EMT
ABOVE FINISHED FLOOR
AIR CONDITIONING UNIT
AMPS
ABOVE COUNTER
AIR HANDLING UNIT
AUTOMATIC TRANSFER SWITCH
AMPS INTERUPTING CAPACITY
AUTHORITY HAVING JURISDICTION
ABOVE SHELF
BOILER
BUILDING
BELOW COUNTER
CHILLER
DOMESTIC WATER HEATER
CABINET UNIT HEATER
CIRCUIT
CIRCUIT BREAKER
CONDUIT
CONDENSING UNIT
COOLING TOWER
DUCT FURNACE
DRAWING
DISCONNECT
FOOD SERVICE EQUIP. SUPPLIER
ELECTRIC WATER COOLER
ELECTRICAL CONTRACTOR
ELECTRIC BASEBOARD
ELECTRICAL METALLIC TUBING
EXISTING
EXHAUST FAN
FLOOR
FLUORESCENT
FLEXIBLE CONDUIT
FULL LOAD AMPS
EM EMERGENCY
F/S FIRE/SMOKE
FU- FURNACE
M
FIXTURE
MOUNTING
HEIGHT
LAMPSDESCRIPTION AND COMMENTSTYPE MANUFACTURER CATALOG NO.
LIGHTING FIXTURE SCHEDULE
NEW STAR LIGHTING 53-24-J-L2-50-1-B-B-UN-DMLA CEILING
50W, 5000K
6500 LUMENS
LED
BALLAST INFO
0-10VLED - 2X4 SURFACE MOUNT CORRECTIONAL FACILITY GRADE LIGHT FIXTURE.
GENERAL ELECTRICAL NOTES
1. ALL WALL AND FLOOR PENETRATIONS ARE TO BE SEALED TO MAINTAIN ORIGINAL RATING.
2. ALL CONDUITS SHALL BE FIELD ROUTED ALONG EXISTING PIPING AND STRUCTURAL STEEL.
3. CONTRACTORS SHALL VISIT THE PROJECT SITE AND DETERMINE THE EXACT EXTENT OF THE DEMOLITION WORK REQUIRED
BEFORE BIDDING THE PROJECT.
4. REMOVE ALL EXISTING OBSOLETE EXPOSED CONDUIT, WIRE AND UNUSED EQUIPMENT WHERE WORK IS BEING DONE EXCEPT
ITEMS NOTED OTHERWISE.
5. WHERE BUILDING SURFACES ARE DAMAGED BY THE REMOVAL OF OLD WORK, SURFACES SHALL BE PATCHED TO MATCH
ADJACENT.
6. EXISTING WORK WHICH IS PRESENTLY CONCEALED AND WHICH WILL REMAIN CONCEALED AND DOES NOT INTERFERE WITH ANY NEW WORK OF ANY TRADE NEED NOT BE REMOVED. HOWEVER, ALL CONDUIT SHALL BE CAPPED BELOW FINISH SURFACE AND
THEN PATCHED TO MATCH, OR AS NOTED.
7. EXISTING OPENINGS, WHICH ARE TO BE REUSED, SHALL BE MODIFIED OR ENLARGED TO SUIT THE NEW SYSTEMS AS REQUIRED.
PROVIDE ALL REQUIRED CUTTING AND PATCHING.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING THE EXISTING WALLS TO MATCH THE ADJACENT SURFACES BEHIND ALL
SURFACE MOUNTED EQUIPMENT.
9. CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT AND LOADS PRIOR TO INSTALLING SERVICE TO EQUIPMENT.
10. DRAWINGS ARE BASED ON EXISTING RECORD DOCUMENT AND CASUAL FIELD OBSERVATION. REPORT ANY DISCREPANCIES TO
ENGINEER FOR CLARIFICATION.
11. CONDUITS AND BOXES:
11.1. 3/4" MINIMUM TRADE SIZE.
11.2. EMT TYPE CONDUIT IS APPROVED.
11.3. NO PVC ALLOWED INSIDE OF BUILDINGS.
11.4. CONDUITS SHALL BE ATTACHED WITH TWO-HOLE STRAPS. SINGLE HOLE STRAPS ARE NOT PERMITTED.
11.5. NO SET SCREWS ARE ALLOWED.
11.6. TAMPER-PROOF SCREWS REQUIRED FOR EXPOSED CONDUIT AND BOXES MOUNTED BELOW TEN FEET.
11.7. DRIVE PIN ANCHORS USED ON MASONRY OR CONCRETE WALLS/ CEILINGS.
12. ALL CONDUIT ABOVE 10 FOOT SHALL MEET THE FOLLOWING REQUIREMENTS:
12.1. STRAP DISTANCE: 5 FEET.
12.2. CONDUIT: INTERIOR EMT, EXTERIOR EXPOSED/ CONCEALED- GRC.
12.3. FITTINGS: COMPRESSION.
12.4. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND ENCLOSURES.
13. ALL CONDUIT BELOW 10 FOOT SHALL MEET THE FOLLOWING REQUIREMENTS:
13.1. STRAP DISTANCE: 3 FEET.
13.2. FASTENERS: 2 HOLE WITH SECURITY SCREWS.
13.3. CONDUIT: INTERIOR EMT, EXTERIOR EXPOSED/ CONCEALED - GRC.
13.4. FITTINGS: COMPRESSION.
13.5. BELL BOXES: FS TYPE.
13.6. NO KNOCKOUTS.
13.7. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND ENCLOSURES
14. ALL EXPOSED WIRING SHALL BE IN CONDUIT. OPEN LOW VOLTAGE WIRING ABOVE CEILINGS IS ACCEPTABLE. REFER TO TC
DRAWINGS FOR SUPPORT DETAILS.
15. CONDUITS SHALL BE INSTALLED STRAIGHT AND LEVEL AND SHALL BE PARALLEL OR PERPENDICULAR TO THE BUILDING LINES.
16. CONTRACTOR SHALL VERIFY ALL VOLTAGES BEFORE CONNECTING ANY EQUIPMENT.
17. ALL LOCATIONS WHERE THE WALLS CAN'T BE FISHED SHALL BE SURFACE MOUNTED CONDUIT FOLLOWING NOTES 11 AND 12
ABOVE.
18. ALL WALLS THAT ARE ACCESSIBLE SHALL BE FISHED AND DEVICE CUT INTO WALL.
19. ALL EXTERIOR CONCEALED CONDUIT UNDERGROUND SHALL BE RNC, TYPE EPC-40-PVC
20. ANY ELECTRICAL OUTAGE SHALL NOT LAST OVER 2-HOURS. FOR OUTAGES OVER PORTABLE GENERATORS SHALL BE USED TO
REPLACE ANY ELECTRICAL SERVICE EXCEEDING THIS TIME PERIOD.
620-SF/DF-LED-UN-RW-EMXA LED - CEILING MOUNT CORRECTIONAL FACILITY GRADE EXIT SIGN. --
NEW STAR LIGHTING 53-24-J-L2-50-1-B-B-UN-DM; ALCR-D10LAEM CEILING
50W, 5000K
6500 LUMENS
LED
0-10VLED - 2X4 SURFACE MOUNT CORRECTIONAL FACILITY GRADE LIGHT FIXTURE CIRCUITED
TO EMERGENCY BACKUP GENERATOR. CONTRACTOR TO PROVIDE A BLTC DEVICE.
1. ALL POWER CABLE SHALL BE INSTALLED IN MINIMUM 3/4" EMT CONDUIT UNLESS
OTHERWISE SPECIFIED.
2. FIRE ALARM CABLE CAN BE INSTALLED FREE AIR ABOVE CEILINGS.
3. PROVIDE RACEWAY WHERE SURFACE MOUNT DEVICES ARE REQUIRED.
CONDUIT SHALL BE 3/4" MINIMUM PAINTED RED.
4. ALL CABLE SHALL BE INSTALLED PER FIRE ALARM MANUFACTURER'S
SPECIFICATIONS.
5. FIRE ALARM REMOTE POWER SUPPLY SHALL BE MONITORED.
6. PROVIDE SMOKE DETECTOR ABOVE ALL FIRE ALARM PANELS AND REMOTE
POWER SUPPLIES.
7. REFER TO DRAWINGS FOR DEVICE QUANTITIES AND LOCATIONS. BRING TO THE
ENGINEER'S ATTENTION DISCREPANCIES PRIOR TO BIDDING PROJECT.
8. UPON ALARM OF SMOKE DETECTORS, FIRE ALARM SYSTEM TO RELEASE DOOR
HOLDERS.
9. POWER SUPPLIES IN BOTH FACP AND FCPS SHALL HAVE 25% SPARE CAPACITY.
10. TRUE PEER TO PEER NETWORK FOR FIRE ALARM SYSTEM.
11. FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR ALL CANDELA RATINGS OF
VISUAL UNITS TO COMPLY WITH NFPA 72. STROBE CANDELA SETTINGS SHALL
BE SET DURING INSTALLATION OF THE DEVICE.
12. REPLACE ALL EXISTING DUCT DETECTORS AS SHOWN ON PRINTS. ANY DUCT
DETECTORS THAT ARE DISCOVERED AND NOT SHOWN SHALL BE BROUGHT TO
THE ENGINEER'S ATTENTION.
13. PROVIDE REMOTE TEST STATIONS FOR EACH DUCT DETECTOR.
14. INSTALLATION METHODS SHALL BE IN ACCORDANCE WITH THE NATIONAL
ELECTRICAL CODE, ARTICLE 760.
15. 120V AC POWER FOR FIRE ALARM SYSTEM ENCLOSURES SHALL NOT SHARE
CONDUIT RACEWAY WITH FIRE ALARM SYSTEM CIRCUITS.
16. FIRE ALARM SYSTEM DEVICES SHALL BE MOUNTED TO ELECTRICAL BOXES AS
REQUIRED AND REFLECTED ON DEVICE INSTALLATION SHEET.
17. STROBE CANDELA SETTINGS SHALL BE SET DURING INSTALLATION OF THE
DEVICE.
18. AREA SMOKE DETECTORS SHALL NOT BE PLACED WITHIN 36-INCHES OF AIR
DISTRIBUTION DIFFUSERS OR RETURN GRILLS.
19. COORDINATE PRERECORDED MESSAGES WITH SPARROW HEALTH SYSTEMS.
20. PROVIDE AND ADD ANY REQUIRED DUCT DETECTORS FOR RTU'S OR MAU'S.
FIRE ALARM NOTES
-NEW STAR LIGHTING
NEW STAR LIGHTING NWDEU-1-L50-UNV-BK; ALCR-D10LBEM WALL
10'-0" AFF
4.8W, 5000K
LED0-10VLED - WALL PACK CORRECTIONAL FACILITY GRADE LIGHT FIXTURE CIRCUITED TO
EMERGENCY BACKUP GENERATOR. CONTRACTOR TO PROVIDE A BLTC DEVICE.
C 360 DEGREE CAMERA
R ev ie w
D
AT
E
3/
/2
BI
D S
ET
AR
C
H
IT
EC
TS
EN
G
IN
EE
R S
M A
T R
I X
M
EN
TA
L
H
EA
LT
H
O
FF
IC
E
R
EM
O D
EL
AN
D A
D D
IT
IO
N
PA
R
N
AL
L C
O R
R
EC
TI
O
N
AL
F
AC
IL
IT
Y
JC
/E
N G
B Y
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A N
C A
R B
D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
PR
O
JE
C T
N O
2/
7.
H
JD
EL
EC
TR
IC
AL
SY
M
BO
LS
AB
BR
EV
N O
TE
S
E-
2/
7.
H
JD
EMERG
PUSH
BUTTONOC
EMERGENCY
ALERT
SYSTEM
EMERG
PUSH
BUTTON
OC
EMERGENCY
ALERT
SYSTEM
EMERGENCY
ALERT
SYSTEM
EMERGENCY
ALERT
SYSTEM
1D
OC
OC
OC
EMERG
PUSH BUTTON
2D
EMERG
PUSH BUTTON
S S S
O
S1OS1
J C
30A
T
T TS
IT
RACK
BLDG 80
CNTRL PNL
PNL RLPN-A1
208/120V-3PH, 400A
PNL SEPN-080D
480/277V-3PH, 400A
PNL D-080-RLPE-A1
208/120V-3PH, 150A
PNL SEPE-080-D
480/277V-3PH, 100A
ATS-80
100A
TE1
45KVA
150KVA
FACP
X-UH
X-UH
X-DWH
X-AC
X-AC
X-ACX-AC
5 55
6 6
OC
4D
EMERG
PUSH
BUTTON
5 4
EMERGENCY
ALERT
SYSTEM 5 7
X-AC 6
6 6
JUNCTION BOX
X-PANEL CSRL
GARAGE POWER 440V-200A
X-30A DISCONNECT 10
5 5 5 5
S
111111 11
J
C
C
X-MAIN CB TRAFFIC
BUILDING
EXISTING LIGHT FIXTURE TO REMAIN.
EXISTING DEVICE TO REMAIN.
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT & REMOVE EXISTING LIGHT FIXTURE. REMOVE ASSOCIATED
CONDUIT & WIRE.
DISCONNECT & REMOVE EXISTING DEVICE. REMOVE ASSOCIATED CONDUIT
& WIRE.
DISCONNECT & REMOVE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT & WIRE.
ALL LIGHT FIXTURES, DEVICES AND EQUIPMENT EXISTING TO REMAIN IN
NOTED ROOM.
DISCONNECT & REMOVE EXISTING DEVICE AND REMOVE ASSOCIATED
CONDUIT & WIRE BACK TO SOURCE ON NOTED WALL.
EXISTING CONDUIT ON EXTERIOR WALL TO REMAIN. RAISE EXISTING
CONDUIT HEIGHT ON EXTERIOR OF THE BUILDING TO ACCOMMODATE THE
INSTALLATION OF NEW DOOR.
DISCONNECT & REMOVE EXISTING EQUIPMENT. EXTEND ASSOCIATED
CONDUIT & WIRE AS REQUIRED.
DISCONNECT EXISTING DEVICE. TURN OVER DEVICE TO OWNER FOR ATTIC
STOCK. REMOVE ASSOCIATED CONDUIT & WIRE.
DEMOLITION NOTES
R ev ie w
D
AT
E
3/
/2
BI
D S
ET
AR
C
H
IT
EC
TS
EN
G
IN
EE
R S
M A
T R
I X
M
EN
TA
L
H
EA
LT
H
O
FF
IC
E
R
EM
O D
EL
AN
D A
D D
IT
IO
N
PA
R
N
AL
L C
O R
R
EC
TI
O
N
AL
F
AC
IL
IT
Y
JC
/E
N G
B Y
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A N
C A
R B
D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
PR
O
JE
C T
N O
2/
7.
H
JD
EL
EC
TR
IC
AL
FL
O O
R P
LA
N
LI
G
H
TI
N G
A N
D P
O W
ER
D
EM
O
LI
TI
O N
E-
2/
7.
H
JD
N ELECTRICAL - FLOOR PLAN - LIGHTING AND POWER - DEMO
SCALE: 3/16" = 1'-0"
10 5 10 13
LA
LA
LA
LA
LA
LA LA
LA
LA
LALA
LALAEM
LA
LA
LA
LA
LA LA
LA
LA LA
LA LAEM
LALALAEM
LA LA
OC
OC
OC
OC
OC
XA
XA
LAEM
LAEM
LAEM
LAEM
LAEM
LAEM
LAEM
XA
XA
XA
XA
OC
OC
OC
OC
OC OC
OS4
PP
OS4
OS4
OS4
OS4
OS4
OS4
OS4
OS4
OS4
OS4
PP
PP
PP
OS4
PP
XA
SEPE-080-D-13
SEPE-080-D-13
SEPE-080-D-13
SEPE-080-D-13
SEPE-080-D-13
SEPE-080-D-13
SEPE-080-D-13
SEPE-080-D-13
SEPE-080-D-13
SEPE-080-D-13
SEPN-080-D-13
SEPN-080-D-13
SEPN-080-D-13
SEPN-080-D-13
SEPN-080-D-13
SEPN-080-D-13
SEPN-080-D-13
SEPN-080-D-13 SEPN-080-D-13
SEPN-080-D-13
SEPN-080-D-13
LA
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX EX EX
SEPE-080-D-13
LBEM
PC
SEPN-080-D-13
GENERAL ELECTRICAL NOTES
1. CONTRACTOR SHALL PROVIDE AND INSTALL LOW VOLTAGE 0-10V
CABLING FOR ALL NEW LIGHT FIXTURES. CONTRACTOR SHALL
TERMINATE CABLE INSIDE LIGHT SWITCH JUNCTION BOX FOR FUTURE
DIMMING CAPABILITIES.
2. EMERGENCY LIGHT FIXTURES SHOULD OPERATE WITH LOCAL
SWITCHING.
3. EMERGENCY EXIT SIGNS SHALL BE WIRED AHEAD OF LOCAL
SWITCHING.
ELECTRICAL KEY NOTES
EXISTING LIGHT FIXTURES AND DEVICES TO REMAIN IN NOTED ROOM.1
R ev ie w
D
AT
E
3/
/2
BI
D S
ET
AR
C
H
IT
EC
TS
EN
G
IN
EE
R S
M A
T R
I X
M
EN
TA
L
H
EA
LT
H
O
FF
IC
E
R
EM
O D
EL
AN
D A
D D
IT
IO
N
PA
R
N
AL
L C
O R
R
EC
TI
O
N
AL
F
AC
IL
IT
Y
JC
/E
N G
B Y
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A N
C A
R B
D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
PR
O
JE
C T
N O
2/
7.
H
JD
EL
EC
TR
IC
AL
FL
O O
R P
LA
N
LI
G
H
TI
N G
N
EW
E-
2/
7.
H
JD
N ELECTRICAL - FLOOR PLAN - LIGHTING
ELECTRICAL KEY NOTES
NEW PNL MH 208/120V-1PH, 100A
CONTRACTOR SHALL FEED NEW PANEL MH FROM NEW 100A/2P BREAKER IN
EXISTING PANEL RLPN-A1.
CONTRACTOR SHALL PROVIDE AND INSTALL NEW 25A/3P BREAKER IN
EXISTING PANEL SEPE-080D.
DISCONNECT BY MANUFACTURER.
RELOCATED EXISTING CONDUIT ON EXTERIOR OF THE BUILDING.
COORDINATE RELOCATION OF EXISTING CONDUIT WITH THE INSTALLATION
OF THE NEW DOOR.
CONTRACTOR SHALL EXTEND EXISTING CIRCUIT FROM EXISTING PANEL
BEING REMOVED TO NEW PANEL AS REQUIRED TO MAINTAIN POWER AT ALL
EXISTING LOADS.
CONTRACTOR SHALL PROVIDE AND INSTALL NEW JUNCTION BOX ABOVE
CEILING FOR INSTALLATION OF NEW PANEL CSRL.
CONTRACTOR SHALL PROVIDE AND INSTALL NEW BREAKER IN EXISTING
PANEL.
LAVATORY CONTROLLER BASED ON I-CON NEXUS MODEL100192 4 I/O AC
CONTROLLER. COORDINATE INSTALLATION REQUIREMENTS WITH
MECHANICAL CONTRACTOR.
DDC TOUCHSCREEN CONTROL PANEL.
GENERAL ELECTRICAL NOTES
1. CONTRACTOR SHALL PROVIDE AND INSTALL NEW SIEMENS FIRE
ALARM DEVICES TO MATCH EXISTING SYSTEMS.
2. CONTRACTOR SHALL TIE NEW DEVICES INTO EXISTING FACP SYSTEM
LOCATED IN MAIN ENTRANCE CORRIDOR.
3. CONTRACTOR SHALL RE-CERTIFY FIRE ALARM SYSTEM ONCE ALL NEW
WORK IS COMPLETE.
4. CONTRACTOR SHALL REFER TO TELECOMMUNICATION DRAWINGS FOR
MORE DETAILS REGARDING TECHNOLOGY AND SECURITY SYSTEMS.
PNL D-080-RLPE-A1
208/120V-3PH, 150A
PNL SEPE-080-D
480/277V-3PH, 100A
X-UH
2D
TV
72" AFF
EXIST.
EMERG
PUSH
BUTTON
1D
2D
T
T TS
IT
RACK
BLDG 80
CNTRL PNL
PNL RLPN-A1
208/120V-3PH, 400A
PNL SEPN-080D
480/277V-3PH, 400A
ATS-80
100A
TE1
45KVA
150KVA
FACP
SL SL
SL SL
SL
SL
SL
SL
EMERG
PUSH BUTTON
EMERGENCY
ALERT
SYSTEM
X-DWH
EMERGENCY
ALERT
SYSTEM
EMERGENCY
ALERT
SYSTEM
EMERGENCY
ALERT
SYSTEM
EMERGENCY
ALERT
SYSTEM
EMERGENCY
ALERT
SYSTEM
EMERGENCY
ALERT
SYSTEM
EMERGENCY
ALERT
SYSTEM
EMERG
PUSH BUTTON
EMERG
PUSH BUTTON
EMERG
PUSH BUTTON
EMERG
PUSH BUTTON
EMERG
PUSH BUTTON
EMERG
PUSH BUTTON
SL
2D
2D
2D
2D 2D 2D
2D
2D
TV
72" AFF
2D
TV
72" AFF
GFI
AC EMERG
PUSH BUTTON
MH-2
MH-4
MH-6
MH-8 MH-10
MH-12
MH-12
MH-12
MH-14
MH-1
MH-3
MH-3
MH-5
MH-9
MH-7
MH-7
MH-13
MH-13
MH-11
C C
C
C
C
C
F
FACP
EXIST. EMERGENCY
ALERT SYSTEM
EF-1
120V-1PH, 2.8A
(ON ROOF)
RTU-1
480V-3PH, 18A
(ON ROOF)
CUH-1
208V-3PH, 8.3A
X-AC
X-AC
SEPE-080D-13,15,17
MH-15
MH-16,18,20
WP WP
GFI
MH-17
NEW PANEL CSRL
6 J
AC-1
208V-1PH, 1A
CU-1
208V-1PH, 9A
(ON ROOF)
WP
D-080-RLPE-A1-25,27
MH-3
VAV-1
120V-1PH, 4A
CP-1
120V-1PH, 2.3A
EX
EXEX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EXEXIST. EMERGENCY
ALERT SYSTEM
EXIST. EMERGENCY
ALERT SYSTEM
EXIST. EMERGENCY
ALERT SYSTEM
EXIST. EMERGENCY
ALERT SYSTEM
EXIST. EMERG
PUSH BUTTON
EXIST. EMERG
PUSH BUTTON
EXIST. EMERG
PUSH BUTTON
MH-19
MH-2
MH-21
MH-23
FROM CU-1
HAND DRYER
120V-1PH, 15A
MH-22
HAND DRYER
120V-1PH, 15A
MH-24
J
J
R ev ie w
D
AT
E
3/
/2
BI
D S
ET
AR
C
H
IT
EC
TS
EN
G
IN
EE
R S
M A
T R
I X
M
EN
TA
L
H
EA
LT
H
O
FF
IC
E
R
EM
O D
EL
AN
D A
D D
IT
IO
N
PA
R
N
AL
L C
O R
R
EC
TI
O
N
AL
F
AC
IL
IT
Y
JC
/E
N G
B Y
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A N
C A
R B
D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
PR
O
JE
C T
N O
2/
7.
H
JD
EL
EC
TR
IC
AL
FL
O O
R P
LA
N
PO
W
ER
N
EW
E-
2/
7.
H
JD
N ELECTRICAL - FLOOR PLAN - POWER
POWER PACK
N
H
LIGHTING
LOAD
LAMPS
CONTROL OUTPUT 24VDC
COMMON
24VDC
PANELBOARD
OCCUPANCY
SENSOR
2 OCCUPANCY SENSOR DETAIL
SCALE: N.T.S.
D A
L O
NEUTRAL
LINE
GREEN/YELLOW
GREEN
BLACK
GROUND
GROUND
RED
1 WALL MOUNTED OCCUPANCY SENSOR DETAIL
SCALE: N.T.S.
R ev ie w
D
AT
E
3/
/2
BI
D S
ET
AR
C
H
IT
EC
TS
EN
G
IN
EE
R S
M A
T R
I X
M
EN
TA
L
H
EA
LT
H
O
FF
IC
E
R
EM
O D
EL
AN
D A
D D
IT
IO
N
PA
R
N
AL
L C
O R
R
EC
TI
O
N
AL
F
AC
IL
IT
Y
JC
/E
N G
B Y
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A N
C A
R B
D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
PR
O
JE
C T
N O
2/
7.
H
JD
EL
EC
TR
IC
AL
PA
N
EL
S C
H
ED
U
LE
S
AN
D D
ET
AI
LS
E-
2/
7.
H
JD