Drawings_2023 06 30 21085_Part3.pdf
PDF 5 MB Posted
- Attached to
- 511/21085. MAA; Midland Armory Construction
- Solicitation number
- RFQ - 171 - 230000000626
- Issued by
- Lenawee County, Michigan
About this file
This document contains details for the Midland Armory Construction state and local contract opportunity issued by the Department of Military and Veteran's Affairs for the State of Michigan. The project involves an addition and renovation to the existing Midland Armory facility located at 2300 Airport Road, Midland, MI 48642. The bid attachments must be uploaded to the SIGMA VSS system, and any questions should be emailed to the designated contact. The bid submission deadline is 2:00 p.m. on the due date, and emailed submissions may be accepted on a case-by-case basis if the bidder is experiencing SIGMA VSS issues.
The contract will be awarded to the successful bidder, but no details are provided on pricing terms, set asides, incumbents, funding requirements and sources, or contract term and renewal options.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BRICK 1, COLOR: MATCHIN EXISTING
MORTAR: MATCH EXISTING
EXTERIOR ELEVATION KEY
BRICK 2, EXISTING
CAST STONE, COLOR: MATCH EXISTING
CJ = CONTROL JOINT, COLOR: SEE SPECS.
EJ - BUILDING EXPANSION JOINT, COLOR:
LOWER FLOOR
100' - 0" (X' - X")
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
TOP MASONRY
117' - 4"
D G K L M PE F H J N R SCBA T
UPPER FLOOR
104' - 0" (X' - X")
UPPER FLOOR
104' - 0" (X' - X")
A 311
A 311
A 311
MEZZANINE FLOOR
109' - 0" (X' - X")
MEZZANINE FLOOR
109' - 0" (X' - X")T Y P
/8
TYP.
1' - 9 1/2"
2' - 0 1/2"2' - 0 1/2" 2' - 0 1/2"
12' - 0"
2' - 0 1/2"
EXISTING RENOVATION
± 151' - 4"
NEW ADDITION
± 65' - 6"
A 321
A 321
A 321
A 311
TOP ELEVATION OF BRICK
EXTERIOR TO MATCH
EXISTING BUILDING
C.J. C.J.
C.J.
25' - 0" 25' - 0"
LOWER FLOOR
100' - 0" (X' - X")
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
TOP MASONRY
117' - 4"
1391316 2456781011121415171819
UPPER FLOOR
104' - 0" (X' - X")
UPPER FLOOR
104' - 0" (X' - X")
A 312
A 312
MEZZANINE FLOOR
109' - 0" (X' - X")
MEZZANINE FLOOR
109' - 0" (X' - X")
TYP.
1' - 9 1/2"
T Y P
/8
2' - 0 1/2"
2' - 0 1/2"
NEW CONSTRUCTION
± 151' - 5"
A 312
A 322
A 322
A 312
16' - 0"
A 312
T O
P O
F B
R
IC
K T
O M
A T C
H E
X
IS
T B
LD
G
M A T C
H E
X
IS
T H T
M A T C
H E
X
IS
T H T
MATCH. EXIST. OPGN.
8' - 10 1/8"
MATCH EXIST. OPGN.
5' - 0 1/4"
T O
P O
F N
E W
B R
IC
K T
O M
A T C H E
X
IS
T
TOP ELEVATION OF BRICK
EXTERIOR TO MATCH
EXISTING BUILDING
C.J. C.J. C.J. C.J. C.J.
25' - 0"
25' - 0" 25' - 0" 25' - 0" 24' - 11" 26' - 6"
C.J.
LOWER FLOOR
100' - 0" (X' - X")
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
TOP MASONRY
117' - 4"
DGKLMP EFHJNRS C B AT
UPPER FLOOR
104' - 0" (X' - X")
UPPER FLOOR
104' - 0" (X' - X")
A 311
A 311
A 311
MEZZANINE FLOOR
109' - 0" (X' - X")
MEZZANINE FLOOR
109' - 0" (X' - X")
EXISTING CONSTRUCTION
± 151' - 5"
A 321
A 321
A 321
A 321
SALVAGED BRICK
OVER NEW CMU WALL
A 311
T O
P O
F N
E W
B R
IC
K T
O M
A T C H E
X
IS
T
NEW ADDITION
± 65' - 6"
TOP ELEVATION OF BRICK
EXTERIOR TO MATCH
EXISTING BUILDING
NEW WALL REPLACEMENT
± 18' - 3 3/4"
8' - 3 3/4"
C.J. C.J. C.J.
25' - 0"25' - 0"
LOWER FLOOR
100' - 0" (X' - X")
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
TOP MASONRY
117' - 4"
9 13 162 4 5 6 7 8 10 11 12 14 15 17 18 19
UPPER FLOOR
104' - 0" (X' - X")
UPPER FLOOR
104' - 0" (X' - X")
A 312
A 312
MEZZANINE FLOOR
109' - 0" (X' - X")
MEZZANINE FLOOR
109' - 0" (X' - X")
A 312
A 321 4
A 312
A 312
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
E X
T E
R
IO
R E
L E
V A
T
IO
N S
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
1/8" = 1'-0"A 301
C EXTERIOR ELEVATION - SOUTH
1/8" = 1'-0"A 301
D EXTERIOR ELEVATION - EAST
1/8" = 1'-0"A 301
A EXTERIOR ELEVATION - NORTH
1/8" = 1'-0"A 301
B EXTERIOR ELEVATION - WEST
MIDLAND ARMORY
KEY PLAN
E
A A
C
DB
SCALE: NO SCALE
EXISTING
NEW
BCD
F G
H
I
ISSUED FOR DATE
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
1391316 2456781011121415171819
UPPER FLOOR
104' - 0" (X' - X")
A 312
A 312
GENERAL
OFFICE
SUPPLY
CORRIDOR
COMMANDER
VESTIBULE
CORRIDOR
VAULT
SUPPLY ROOM
PLATOON 2
PLATOON 2
CORRIDOR
A 312
A 312
PES 200
UNIFORM
STORAGE
A 312
NEW ADDITION
± 145' - 9" 5' - 8"
A 321
SIM A 321
SIM
EXTEND RATED CMU
WALLS TO DECK.
FIRESTOP PENETRATIONS
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
1391316 24567810111214151718
UPPER FLOOR
104' - 0" (X' - X")
A 312
A 312
MEZZANINE FLOOR
109' - 0" (X' - X")
A 312
WORKOUT
ROOM
MEZZANINE
CHAIR TABLE
STORAGE
CORRIDOR
STORAGE
FAMILY
SIPR
CORRIDOR
BREAK ROOM
CORRIDOR
A 312
NEW ADDITION
± 151' - 5"
A 321
SIM
O.H.
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
1316 1415171819
UPPER FLOOR
104' - 0" (X' - X")
A 312
STORAGE
VESTIBULE
223 CORRIDOR
CORRIDOR
A 321
SIM
EXTEND RATED CMU
WALLS TO DECK.
FIRESTOP PENETRATIONS
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
1391316 2456781011121415171819
UPPER FLOOR
104' - 0" (X' - X")
A 312
A 312
A 312
A 312
PLATOON
PLATOON
OFFICE
CONFERENCE
VESTIBULE
COMM
NBC
VESTIBULE
PES 200
UNIFORM
STORAGE
A 312
NEW ADDITION
± 151' - 5"
A 321
SIM
A 321
SIMEXTEND RATED CMU
WALL(S) TO DECK.
FIRESTOP PENETRATIONS
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
B U
IL
D
IN
G
S E
C T
IO
N
S
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
1/8" = 1'-0"A 311
3 BUILDING SECTION C
MIDLAND ARMORY
KEY PLAN
E
A A
C
DB
SCALE: NO SCALE
EXISTING
NEW
BCD
F G
H
I
1/8" = 1'-0"A 311
4 BUILDING SECTION D
1/8" = 1'-0"A 311
2 BUILDING SECTION B
1/8" = 1'-0"A 311
1 BUILDING SECTION A
TOP MASONRY
117' - 4"
DGKLMP EFHJNRS C B AT
A 311
A 311
A 311
MEZZANINE FLOOR
109' - 0" (X' - X")
VESTIBULE
CORRIDOR
ASSEMBLY
HALL
140 VESTIDULE
A 311
NEW ADDITION
65' - 6"
EXISTING BUILDING RENOVATION
± 151' - 5"
A 322
SIM
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
ST
A 311
A 311
A 311
A 311
NBC
VAULT
SUPPLY ROOM
MEZZANINE
CHAIR TABLE
STORAGE
NEW ADDITION
± 65' - 6"
A 322
SIM
A 321
SIM
CAGING TO EXTEND TO WITHIN 3" OF ALL
BUILDING ELEMENTS (ROOF DECK, STRUCTURE,
DUCTWOK, ETC
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
T
A 311
A 311
A 311
COMM
PLATOON 3
PLATOON 2
PLATOON 1
209 SUPPLY OFFICE
SUPPLY ROOM
WORKOUT
ROOM
A 322
SIM
A 321
SIM
CAGING TO EXTEND TO WITHIN 3" OF ALL
BUILDING ELEMENTS (ROOF DECK, STRUCTURE,
DUCTWOK, ETC
LOWER FLOOR
100' - 0" (X' - X")
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
TOP MASONRY
117' - 4"
D G K L M PE F H J N R SCBA T
UPPER FLOOR
104' - 0" (X' - X")
UPPER FLOOR
104' - 0" (X' - X")
A 311
A 311
MEN'S
SHOWER
MEN'S
RESTROOM
MENS TOILET
VESTIBULE
WOMENS
TOILET
RECRUIT
TRAINING
GENERAL
OFFICE
VESTIBULE
PLATOON
A 311
RECRUIT
BREAK ROOM
A 311
EXISTING BUILDING RENOVATION
± 151' - 4"
A 322
SIM
A 321
SIM
O.H.
O.H.
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
DGKLMP EFHJNRS C B AT
A 311
A 311
A 311
A 311
PES 200
UNIFORM
STORAGE
STORAGE
MESS OFFICE
COLD FOOD
PREP
HOT FOOD
PREP
SCULLERY
Room
400-492
TOILET
WOMENS
TOILET
EXISTING BUILDING RENOVATION
± 151' - 5"
NEW ADDITION
± 65' - 6"
A 322
SIM
A 321
SIM
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
B U
IL
D
IN
G
S E
C T
IO
N
S
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
1/8" = 1'-0"A 312
2 BUILDING SECTION F
1/8" = 1'-0"A 312
3 BUILDING SECTION G
1/8" = 1'-0"A 312
4 BUILDING SECTION H
1/8" = 1'-0"A 312
5 BUILDING SECTION I
1/8" = 1'-0"A 312
1 BUILDING SECTION F
TOP MASONRY
117' - 4"
A 321
1A
A 321
1B
WOOD BLOCKING
ALUM EXTRUSION
4" (NOM) BRICK,
MATCH EXISTING
8" CMU
INSULATED ROOF
METAL DECK
3" INSULATION
13/4" AIR SPACE
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
A 321
2B
A 321
2C
A 321
2A
WOOD BLOCKING
TO REMAIN
EXISTING METAL
FASCIA TO REMAIN
±4" SALVAGED
UTILITY BRICK
4" CMU
STORE FRONT
EXISTING ROOF
TO REMAIN
EXISTING
STRUCTURAL
TO REMAIN
3" INSULATION
± 2 1/4" AIR SPACE
EXISTING STEEL
JOIST
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
A 321
2A
SIM
EXISTING WOOD
BLOCKING TO REMAIN
EXISTING METAL
FASCIA TO REMAIN
4" UTILITY BRICK,
MATCH EXISTING
4" CMU
EXISTING ROOF
TO REMAIN
EXISTING
STRUCTURAL TO
REMAIN
± 1 1/4" AIR SPACE
EXISTING STEEL
JOIST
NEW FLOST
SLAB, SEE
STRUCTURAL
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
A 321
4B
A 321
4A
A 321
2A
SIM
EXISTING WOOD
BLOCKING TO REMAIN
EXISTING METAL
FASCIA TO
REMAINFASCIA
4" CMU
INSULATED
PANEL GARAGE
DOOR
EXISTING
STRUCTURAL TO
REMAIN
3" INSULATION
± 2 1/4" AIR SPACE
±4" SALVAGED
UTILITY BRICK
NEW FLOST
SLAB, SEE
STRUCTURAL
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
A
A 321
5A
A 321
5B
E X
IS
T
IN
G B
R
IC
K /C
M U W
A
LL
T O
R E M
A
IN
/4
/4
±4" SALVAGED
UTILITY BRICK
4" CMU
3" INSULATION
± 2 1/4" AIR SPACE
E X
IS
T
IN
G
B R
IC
K W
A
LL
T O
R E M
A
IN
E X
IS
T
B R
IC
K W
O
R E M
A
IN
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
UPPER FLOOR
104' - 0" (X' - X")
A 321
6A
A 321
6B
E X
IS
T
IN
G B
R
IC
K /C
M U W
A
LL
T O
R E M
A
IN
N E W
I N F
IL
L W
A
LL
± 4" SALVAGED
UTILITY BRICK
4" CMU
3" INSULATION
± 2 1/4" AIR
SPACE N
E W
I N F
IL
L W
A
LL
E X
IS
T
IN
G B
R
IC
K /C
M U
W
LL
T O
R E M
A
IN
TOP MASONRY
117' - 4"
UPPER FLOOR
104' - 0" (X' - X")
A 321
7A
A 321
7B
A 321
1A
SIM
/8
/8
WOOD BLOCKING
METAL FASCIA
4" UTILITY BRICK,
MATCH EXISTING
8" CMU
INSULATED ROOF
METAL DECK
3" INSULATION
1 3/4" AIR SPACE
8" CMU
CEILING, SEE
REFLECTED CEILING
PLAN
CAST STONE SILL
NEW WINDOW
0"
TOP MASONRY
117' - 4"
UPPER FLOOR
104' - 0" (X' - X")
WOOD BLOCKING
METAL FASCIA
UTILITY BRICK,
MATCH EXISTING
8" CMU
INSULATED ROOF
METAL DECK
3" INSULATION
1" AIR SPACE
GYPSUM BOARD
CEILING, SEE
REFLECTED CEILING
A 321
1A
SIM
A 321
8B
TOP MASONRY
117' - 4"
4" (NOM) BRICK,
MATCH EXISTING
3" RIGID
INSULATION, SEAL
3" INSULATION
1 3/4" AIR SPACE
1' - 1 5/8"
ALUM GRAVEL
STOP PROFILE
AND HEIGHT TO
MATCH EXISTING
1/2" COVER BOARD
5" RIGID INSULATION
METAL DECK, SEE
STRUCTURAL
STEEL JOIST, SEE
STRUCTURAL
EPDM ROOF
MEMBRANE
(2) TRT 2X4
STACKED. 24"
O.C. WITH INSUL
BETWEEN
/1
M T A C H E
X
IS
T
EPDM ROOF
MEMBRANE
PREBUCK
PARAPET CAP
LOWER FLOOR
100' - 0" (X' - X")
8" CMU
3" INSULATION
1 3/4" AIR SPACE
10 5/8"
CONCRETE
FOUNDATION
WALL FOOTING,
SEE STRUCTURAL
FLOOR SLAB
1' - 4"
3" RIGID
INSULATION
2" RIGID
INSULATION
CAVITY DRAINAGE
MESH
GROUT SOLID
WEEPS AT 24" O.C.
CONCRETE
APRON, SEE
CIVIL
4" UTILITY BRICK,
MATCH EXISTING
MEMBRANE
FLASHING
BOND BREAKER
MATERIAL
4" UTILITY BRICK,
MATCH EXISTING
8" CMU
1" AIR SPACE
LINTEL - REFER
TO STRUCTURAL
SEALANT ON
BOTH FACES
ALUMINUM
DOOR FRAME
CAVITY DRAINAGE
MESH
FLASHING
MEMBRANE
LOWER FLOOR
100' - 0" (X' - X")
THERMALLY BROKEN
ALUMINUM
STOREFRONT DOOR
WITH INSULATED GLASS
DOOR
THRESHOLD
EXISTING
CONCRETE
FOOTING
EXISTING
CONCRETE
FLOOR SLAB
1 3/4" 2" 4"ALUM. SNAP TRIM
AND CLIP
4 3/4"
NEW FROST
SLAB, SEE
STRUCTURAL
OVERHEAD DOOR
OVERHEAD
DOOR TRACK
PAINTED STEEL
TUBE LINTEL AND
PLATE - REFER
TO STRUCTURAL
4" UTILITY BRICK,
MATCH EXISTING
AIR SPACE
8" CMU
WEEPS AT 24"
O.C.
CAVITY DRAINAGE
MESH
LOWER FLOOR
100' - 0" (X' - X")
NEW FLOST
SLAB, SEE
STRUCTURAL
GARAGE
DOOR
EIXSTING
STRUCTURE
BOND BREAKER
MATERIAL
3" RIGID
INSULATION
2" RIGID
INSULATION
A
M
IN
EXISTING UTILITY
VENEER OVER CMU
WALL
5/8" GYPSUM OVER
3 5/8" METAL
STUDS, 16" O.C.
GYPSUM BOARD
CELING, SEE
REFLECTED CEILING
PLAN
A
LI
G N
4" CMU
3" INSULATION
±2 1/4" AIR SPACE
5/8"3 5/8"3 5/8"3"
2 1/4"
3 5/8"
MORTAR JOINT,
MATCH EXISTING
±4" SALVAGED
UTILITY BRICK
LOWER FLOOR
100' - 0" (X' - X")
A
5/8" GYPSUM OVER
METAL STUDS, 16"
O.C., SEE FLOOR
PLAN
EXISTING
FLOOR SLAB
SEALANT
EXISTING UTILITY
VENEER OVER CMU
WALL TO REMAIN
A
LI
G N
4" CMU
3" INSULATION
±2 1/4" AIR SPACE
5/8"3 5/8"3 5/8"3" 2 1/4"
3 5/8"
MORTAR JOINT,
MATCH EXISTING
±4" SALVAGED
UTILITY BRICK
INFILLE BRICK
VENEER WHERE
SILL IS REMOVED,
MATCH EXISTING
UTILITY BRICK FILL VOID WITH 4"
CMU
FILL WITH MORTAR
EXISTING CMU
WALL(s) TO REMAIN
4" UTILITY BRICK,
MATCH EXISTING
3" INSULATION
1 3/4 AIR SPACE
8" CMU
TILE CEILING, SEE
REFLECTED
CEILING PLAN
ALUMINUM
WINDOW FRAME
SEALANT BOTH
FACES
MATCH EXIST.
± 8 1/2"
3 5/8"1 3/4" 3" 7 5/8"
1' - 4"
UPPER FLOOR
104' - 0" (X' - X")
4" UTILITY BRICK,
MATCH EXISTING
3" INSULATION
1 3/4" AIR SPACE
8" CMU
ALUMINMUM
WINDOW FRAME
SOLID SURFACE
WINDOW SILL.
SEE FINISH PLAN
ALUMINUM SILL
FLASHING
MEMBRANE
FLASHING.
EXTEND UNDER
WINDOW SUBSILL
CAVITY DRAINAGE
MESH
WEEPS AT 24" O.C.
CAST STONE SILL,
MATCH EXISTING
PROFILE
3 5/8" 1 3/4" 3" 7 5/8"
1' - 4"
± 4" SALVAGED
UTILITY BRICK
4" CMU
3" INSULATION
± 2 1/4" AIR SPACE
EXISTING
UTILITY BRICK
A
LI
G N
5/8" GYPSUM OVER
3 5/8" METAL
STUDS, 16" O.C.
GYPSUM CEILING
UPPER FLOOR
104' - 0" (X' - X")
± 4" SALVAGED
UTILITY BRICK
4" CMU
3" INSULATION
± 2 1/4" AIR SPACE
EXISTING BRICK
VENEER BELOW
TO REMAIN
3 5/8" 2 1/4"
3" 3 5/8"
INFILLE BRICK
VENEER WHERE
SILL IS REMOVED,
MATCH EXISTING
UTILITY BRICK
FILL VOID
WITH 4" CMU
EXISTING
CONCRETE
SLAB
EXISTING
CMU WALL(s)
TO REMAIN
A
LI
G N
FILL WITH MORTAR
MORTAR JOINT,
MATCH EXISTING
TOP MASONRY
117' - 4"
4" UTILITY BRICK,
MATCH EXISTING
8" CMU
1" AIR SPACE
EXISTING FASCIA
TO REMAIN
EXISTING WOOD
BLOCK(s) TO REMAIN
EXISTING ROOF
TO REMAIN
EXISTING STEEL
JOIST
EXITING BRICK
ANGLES, REMOVE
AND REINSTALL WITH
WALL CONSTRUCTION
EXISTING STEEL
ANGLE
BRICK TO REMAIN
4" UTILITY BRICK,
MATCH EXISTING
3" INSULATION
1" AIR SPACE
8" CMU
ALUMINUM
WINDOW
SEALANT ON
BOTH FACES
MORTAR JOIST
CAST STONE SILL, MATCH
DIMENSIONS TO EXISTING
M A T C
H E
X
IS
T
IN
G
/2
SILL FLASHING
UPPER FLOOR
104' - 0" (X' - X")
3" INSULATION
1 3/4" AIR SPACE
CAVITY DRAINAGE
MESH
GROUT SOLID
WEEPS AT 24" O.C.
4" UTILITY BRICK,
MATCH EXISTING
MEMBRANE
FLASHING
2" RIGID
INSULATION
CONCRETE
FOOTING, SEE
STRUCTURAL
BOND BREAKER
MATERIAL
3" RIGID
INSULATION
8" CMU
1 3/4" 3" 7 5/8"3 5/8"
1' - 4"
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
W A
L L
S E
C T
IO
N
S
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
1/2" = 1'-0"A 321
1 WALL SECTION
1/2" = 1'-0"A 321
2 WALL SECTION
1/2" = 1'-0"A 321
3 WALL SECTION
1/2" = 1'-0"A 321
4 WALL SECTION
1/2" = 1'-0"A 321
5 WALL SECTION
1/2" = 1'-0"A 321
6 WALL SECTION
1/2" = 1'-0"A 321
7 WALL SECTION
1/2" = 1'-0"A 321
8 WALL SECTION
1 1/2" = 1'-0"A 321
1A WALL DETAIL
1 1/2" = 1'-0"A 321
1B WALL DETAIL
1 1/2" = 1'-0"A 321
2B WALL DETAIL
1 1/2" = 1'-0"A 321
2C WALL DETAIL
1 1/2" = 1'-0"A 321
4A WALL DETAIL
1 1/2" = 1'-0"A 321
4B WALL DETAIL
1 1/2" = 1'-0"A 321
5A WALL DETAIL
1 1/2" = 1'-0"A 321
5B WALL DETAIL
1 1/2" = 1'-0"A 321
7A WALL DETAIL
1 1/2" = 1'-0"A 321
7B WALL DETAIL
1 1/2" = 1'-0"A 321
6A WALL DETAIL
1 1/2" = 1'-0"A 321
6B WALL DETAIL
1 1/2" = 1'-0"A 321
2A WALL DETAIL
1 1/2" = 1'-0"A 321
7C JAMB DETAIL
1 1/2" = 1'-0"A 321
8B WALL DETAIL
TOP MASONRY
117' - 4"
A 322
1A
A 321
1A
SIM
A 322
1B
WOOD BLOCKING
METAL FASCIA
4" UTILITY BRICK,
MATCH EXISTING
4" CMU
INSULATED ROOF
METAL DECK
STOREFRONT
4' - 6 3/8"
3" INSULATION
1" AIR SPACE
3 5/8" METAK STUD,
ADD BRACING AS
NEEDED
3 1/2" INSULATION
NEW FLOST
SLAB, SEE
STRUCTURAL
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
WOOD BLOCKING
METAL FASCIA
INSULATED ROOF
METAL DECK
DOOR
4' - 6 3/8"
A 322
1A
SIM
A 322
1B
SIM
A 321
1A
SIM
4" UTILITY BRICK,
MATCH EXISTING
4" CMU
3" INSULATION
1" AIR SPACE
3 5/8" METAL STUD,
ADD BRACING AS
NEEDED
3 1/2" INSULATION
NEW FLOST
SLAB, SEE
STRUCTURAL
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
A 322
3A
A 322
3B
A 321
1A
SIM
WOOD BLOCKING
METAL FASCIA
4" UTILITY BRICK,
MATCH EXISTING
8" CMU
INSULATED ROOF
METAL DECK
3" INSULATION
1" AIR SPACE
FROST
CONCRETE
SLAB, SEE
STRUCTURAL
4" UTILITY BRICK,
MATCH EXISTING
8" CMU
3" INSULATION
1" AIR SPACE
STEEL LINTEL,
SEE STRUCTURAL
MEMBRANE
FLASHING
3 5/8" 8"
ALIGN
WEEPS AT
24" O.C.
CAVITY
DRAINAGE MESH
EIFS FINISH OVER
GYPSUM BOARD
SHEATHING (EXTERIOR),
SEE REFLECTED CEILING
PLAN
4" UTILITY BRICK,
MATCH EXISTING
8" CMU
3" INSULATION
1" AIR SPACE
STEEL LINTEL,
SEE STRUCTURAL
MEMBRANE
FLASHING
CAVITY
DRAINAGE MESH
WEEPS AT 24"
O.C.
SEALANT JOINTS,
BOTH FACES
MATCH EXIST.
LOWER FLOOR
100' - 0" (X' - X")
THERMALLY BROKEN
ALUMINUM
STOREFRONT DOOR
WITH INSULATED GLASS
DOOR
THRESHOLD
CONCRETE
FLOOR SLAB, SEE
STRUCTURAL
ALUM. SNAP TRIM
AND CLIP
CONCRETE
FOUNDATION WALL,
SEE STRUCTURAL
BOND BREAKER
MATERIAL
FROST SLAB,
SEE STRUCTURAL 3" RIGID
INSULATION
2" RIGID
INSULATION
2X WOOD
BLOCKING
1X WOOD
BLOCKING
ALUMINUM
STOREFRONT DOOR
AND FRAMES
SEALANT JOINTS,
BOTH FACES
EIFS FINISH OVER
GYPSUM BOARD
SHEATHING
(EXTERIOR), SEE
REFLECTED CEILING
PLAN
GYPSUM
SHEATHING
BATT
INSULATION,
R-19
GYPSUM BOARD
CEILING, SEE
REFLECTED
CEILING PLAN
LOWER FLOOR
100' - 0" (X' - X")
TOP MASONRY
117' - 4"
T
A 322
4A
P O
R T
IO
N S O
F T
H E W
A
LL
B E C O
M E S N
E W
C M
U T
O R
E P
LA
C E E
X
IS
T
IN
G W
WOOD BLOCKING EXISTING METAL
FASCIA
INSULATED ROOF
METAL DECK
12" CMU
EXISTING ROOF
WOOD BLOCKING
REMAINING SECTIONS OF
EXISTING CMU WALLS
SHARE SIMILAR DETAIL
REFER TO FLOOR PLAN
A 322
4B
TOP MASONRY
117' - 4"
T
12" CMU
3" INSULATION
5" RIGID
INSULATION
TAPERED
INSULATION
2X WOOD BLOCKING(s)
EPDM MEMEBRANE.
1/2" COVER
BOARD
PAINTED METAL FASCIA
EXISTING METAL
FASCIA TO REMAIN
EXISTING ROOF
TO REMAIN
EXISTING WOOD
BLOCKS TO REMAIN
CANT STRIP
/2
LOWER FLOOR
100' - 0" (X' - X")
T
NEW FLOOR
SLAB
NEW CMU
WALL, ALIGN
WITH EXISTING
EXISTING
CONCRETE
FLOOR SLAB
EXISTING
FOUNDATION
3" RIGID
INSULATION
2" RIGID
INSULATION
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
W A
L L
S E
C T
IO
N
S
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
1/2" = 1'-0"A 322
1 WALL SECTION
1/2" = 1'-0"A 322
2 WALL SECTION
1/2" = 1'-0"A 322
3 WALL SECTION
1 1/2" = 1'-0"A 322
1A WALL DETAIL 1 1/2" = 1'-0"A 322
3A WALL DETAIL
1 1/2" = 1'-0"A 322
3B WALL DETAIL
1 1/2" = 1'-0"A 322
1B WALL DETAIL
1/2" = 1'-0"A 322
4 WALL SECTION
1 1/2" = 1'-0"A 322
4A WALL DETAIL
1 1/2" = 1'-0"A 322
4B WALL DETAIL
CMU
UTILITY BRICK
VENEER
3" RIGID INSULATION
BOARD. SEAL ALL JOINTS
WITH SPRAY FOAM
/8
/8
EXISTING
CMU WALL
1' - 0 1/8"
CONTROL JOINT
AIR GAP
/8
/4
/8
7 5/8"
CMU
UTILITY BRICK
VENEER
3" RIGID INSULATION
BOARD. SEAL ALL JOINTS
WITH SPRAY FOAM
AIR GAP
/8
/4
/8
7 5/8"
NEW VENEER
BRICK
CONCRETE VAULT
WALLS
CMU WALL
3" INSULATION
CONTROL JOINT
1 3/4" AIR GAP
/8
/4
/8
/8
/4
/8
7 5/8"
/8
CMU
UTILITY BRICK
VENEER
3" RIGID INSULATION
BOARD. SEAL ALL JOINTS
WITH SPRAY FOAM
AIR GAP
T
CMU
EXISTING
CMU/ BRICK
WALL
UTILITY BRICK
VENEER
/8
/4
/8
3" RIGID INSULATION
BOARD. SEAL ALL
JOINTS WITH SPRAY
FOAM
5/8" GYPSUM
BOARD ON 2 1/2"
METAL STUDS
SEAL JOINT
CONTROL JOINT
/8
AIR GAP
D
CMU
EXISTING
CMU/ BRICK
WALL UTILITY BRICK
VENEER
3' - 4"
/8
3 5/8" 1 1/4"
3 5/8"
/8
2' - 7 1/4"
/8
/4 "3
/8
A
LI
N
EXISTING PORTION OF
WALL-MOUNTED
HANDRAIL TO REMAIN
CUT EXISTING
HANDRAIL TO MEET
WALL
EXISTING BRICK
VENEER TO REMAIN
AIR GAP
D
3' - 4"
CMU
UTILITY BRICK
VENEER
/2
3 5/8"
1 1/4"
3 5/8"
/8
/4
/8
EXISTING
CMU/ BRICK
WALL
EXISTING BRICK
VENEER TO REMAIN
A
LI
AIR GAP
CONTINUOUS SEALANT
WITH 3/8"x3"
COMPRESSIBLE BACKER
ROD
FACE BRICK - REFER TO
ELEVATIONS
NOTE:
• SASH BLOCK UNITS REQUIRED FULL
HEIGHT, BOTH SIDES OF JOINT, USING
WHOLE AND HALF BLOCK SASH UNITS
FOR A RUNNING BOND COURSING
APPEARANCE - USING SASH UNITS AT
ALTERNATE COURSES IS NOT
ACCEPTABLE AND JOINTS CONSTRUCTED
THIS WAY WILL BE REMOVED AND
REPLACED AT CONTRACTOR'S EXPENSE
• TRUSS TYPE HORIZONTAL MASONRY
WALL JOINT REINFORCING AT INTERIOR
MASONRY WALLS ONLY - LADDER TYPE
HORIZONTAL MASONRY WALL JOINT
REINFORCING (AS SHOWN) AT EXTERIOR
WALLS
• REFER TO FLOOR PLAN FOR WALL
THICKNESS AND UNIT TYPE
HORIZONTAL WALL REINFORCING
AT 16" O.C. WITH PINTLE-EYE
VENEER ATTACHMENT - DO NOT
EXTEND REINFORCING THROUGH
CONTROL JOINT
3" INSULATION
SEALANT WITH BACKER ROD BOTH
SIDES OF BLOCK
MASONRY CONTROL INSERT WITH SASH
UNIT BOTH SIDES (REFER TO NOTE ABOVE)
/8
/4
/8
A T
B
LO
C K
A T
B
LO
C K
1 3/4" AIR GAP
CONTINUOUS SEALANT WITH
3/8"x3" COMPRESSIBLE
BACKER ROD, WHERE OCCURS
FACE BRICK - MATCH SECTION
OF EXISTING
SAWCUT BRICK AS REQUIRED TO
INSTALL AROUND COLUMN, INFILL WITH
NEW, MATCH EXISTING BRICK
STEEL COLUMN - REFER TO
STRUCTURAL FOR LOCATION
CONTINUOUS FABRIC FLASHING
ADHERED TO MASONRY
/2
/8
/4
/8
EXISTING CMU WALL
AIR GAP
SEAL AT BOTTOM WHERE NEW
BASE PLATE IS INSTALLED
BRICK VENEER INFILL
FACE BRICK
S E E P
LA
N
CONTINUOUS SEALANT WITH
3/8"x3" COMPRESSIBLE
BACKER ROD
CMU
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
P L A
N D
E T
A
IL
S
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
1 1/2" = 1'-0"A 351
1 PLAN DETAIL
1 1/2" = 1'-0"A 351
2 PLAN DETAIL
1 1/2" = 1'-0"A 351
3 PLAN DETAIL
1 1/2" = 1'-0"A 351
4 PLAN DETAIL
1 1/2" = 1'-0"A 351
5 PLAN DETAIL
1 1/2" = 1'-0"A 351
6 PLAN DETAIL
1 1/2" = 1'-0"A 351
7 Detail 16
1 1/2" = 1'-0"A 351
8 CONTROL JOINT @ EXTERIOR WALL
1 1/2" = 1'-0"A 351
9 CONTROL JOINT DETAIL AT NEW COLUMN
1 1/2" = 1'-0"A 351
10 CONTROL JOINT DETAIL AT CMU
STAIR
STAINLESS STEEL
FRAMED MIRROR
HAND DRYER
PAPER
TOWEL
DISPENSER
SOAP
DISPENSER
SANITARY NAPKIN
DISPENSER
TOILET PAPER
DISPENSER
O F R
E F
LE
C
TI
V E S
U R F A C E
T
O B
O
TT
O M
'-0
M
A X.
TOILET PAPER
DISPENSER
M
IN
M
IN
BABY CHANGING STATIONTOP OF WORK
SURFACE @ 34" A.F.F
TOILET PAPER
DISPENSER
M
IN
URINAL SCREEN
TOILET PARTITION
M A X.
M A X.
FIRE
EXTINGUISHER
CABINET
INTERIOR
SIGNAGE
M
IN
18" DEEP MIN.
TO
B
A S E O
R B
R A
IL
LE
M
A X.
M
IN
3' - 4"
M
IN
/2 M
IN
M
IN
42" MIN.12" MAX.
36" MIN.
24" MIN. 12" MIN.
1' - 6" MAX
1' - 4" MIN
COORDINATE GRAB
BAR HEIGHT WITH
FLUSH VALVE -
MAX. HEIGHT 36"
FLUSH HANDLE TO BE
LOCATED ON OPEN
SIDE OF STALL FROM FINISHED
FACE OF WALL
24" MIN.
ACCESSORY MATRIX NOTES
1. OP = OWNER PURCHASED, OI = OWNER INSTALLED, CP = CONTRACTOR PURCHASED, CI = CONTRACTOR INSTALLED.
2. DIMENSIONS INDICATED ARE TYPICAL UNLESS NOTED OTHERWISE ON PLANS.
3. GENERIC PLUMBING FIXTURES ARE SHOWN. REFER TO PLUMBING DRAWINGS AND SPECIFICATIONS FOR FIXTURE TYPES, MANUFACTURERS AND MOUNTING HEIGHTS.
4. CODE REQUIRED INTERIOR SIGNAGE - INCLUDES MINIMUM REQUIRED SIGN TYPES REQUIRED FOR OCCUPANCY AS
DICTATED BY IBC, IFC, AND NFPA. COORDINATE WITH ANY OWNER-PROVIDED SIGNAGE.
D
CBA
/4
/4
/4
/4
3 5/8" 6' - 5 1/2" 11' - 5 1/2" 3 5/8"
7 5/8"
/8
3' - 0"3' - 0"
6' - 1"
6' - 1" 5
2G
/8
/8
2G
1L
1L
1G 1G
1L
1L
1L
2H
± 3' - 4"
/2
/2
7 5/8"
/8
12 1210 9
WOMENS
TOILET
2G
15 15
4"
WALL INFILL,
MATCH
EXISTING
WALL INFILL,
MATCH
EXISTING
ALIGN
ALIGN
1' - 6"
5' - 0" CLR.
WOMEN'S
SHOWERS
9 LOCKERS
9' - 0"
BUILT-IN LOCKER
BENCH, SEE
DETAIL 5 / A421
METAL LOCKERS
5' - 0"
5'-0" x 1'-4"
COUNTER @
3'-0" AFF
G
F
MENS TOILET
/2
5' - 0"
/2
/8
/8
1 4
1' - 3 5/8" 11' - 10" 1' - 3 5/8"
7 5/8"
/2
/2
/4
1' - 3 5/8" 11' - 10"
7' - 1 7/8"
1' - 3 5/8"
2' - 1"
THIS IS AN
AMBULATORY STALL
WITH HANDRAIL ON
EACH SIDE AND A 2'-8"
DOOR.
D
E FCBA
MEN'S
RESTROOM
MEN'S
SHOWER
MEN'S LOCKER
3 5/8" 3' - 1 1/4" 3' - 9 1/4" 3' - 9 1/4" 3' - 9 1/4"
12 1212
/8
/8
5' - 0" CLR.
3' - 9 1/4" 3' - 9 1/4"
4"
1' - 8 1/2"
/4
/2
7' - 10"
19' - 4 1/8" 1' - 3 5/8"
12' - 1 3/4"
8' - 2"
/4
3 5/8" 3' - 1 1/4" 3' - 9 1/4" 3' - 9 1/4" 3' - 9 1/4" 3' - 9 1/4" 3' - 9 1/4"
1L
2G
2G
2G 1L
2G
/8
2H
5' - 0" 1' - 3 3/4"
E Q
E Q
/8
E Q
E Q
2H
18 LOCKERS
18' - 0"
15151515
1L
15151515
1L 1L1L
1L 1L
1L
± 1' - 9 1/2"WALL INFILL,
MATCH
EXISTING
11 11
1' - 4" 2' - 2"
C
LR
L
O C K E R S
/8
2' - 0"
LOCKER FILLER
PANEL BY LOCKER
MANUFACTURER
CORNER LOCKER FILLER
PANEL NAD SLOPE TOP
CORNER BY LOCKER
MANUFACTURER
BUILT-IN LOCKER
BENCH, SEE
DETAIL 5 / A421
METAL LOCKERS
77 7
C
LR
7 7
19 19
C
LR
19 19
19 19 19 19 19 19
17 17 17 17 17
17 17 17 17 17 17
L M
WOMENS
TOILET
/8
C
LR
6 5
A
LI
G N
/8
DUAL HEIGHT WATER
FOUNTAIN WITH
WATER COOLER
8' - 6 1/8"
1' - 3 5/8"
1G
A 631
2' - 1"
S E E S
P E C
IF
IC
A
TI
O N S
/2
1" 1' - 6" 1' - 3 1/2"
3/4" SOLID SURFACE
BENCH ON 3/4"
PLYWOOD - RADIUS
EDGE
6" CONCRETE
MASONRY UNIT
8" CONCRETE
MASONRY UNIT
2"x PRESSURE
TREATED WOOD
NAILER
2"x6" PRESSURE
TREATED WOOD
FRAMING @
16" O.C.
2"x4" PRESSURE
TREATED WOOD
NAILER
METAL
LOCKERS - REFER
TO PLAN
SPACER BY
METAL LOCKER
MANUFACTURER
4" 2' - 0" 8" 8" 2' - 0" 4"
SHOWER PLUMBING
WALL, SHARED
SHOWER BENCH
SHOWER BENCH
DOOR HINGE
FASTENED TO
SHOWER
PLUMBING WALL
OVERHEAD BRACES,
FASTERNED TO
SHOWER PARTITIONS
DOOR HINGE
FASTENED TO
SHOWER
PLUMBING WALL
SHOWER PARITION
DOORS AND
SUPPORTS
NOTE:
SIMILAR CONDITION
OCCURS IN BOTH
SHOWER ROOMS
SHOWER PARTITION
WITHOUT PLUMBING
SHOWER PARTITION
WITHOUT PLUMBING
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
E N
L A
R G
E D
P L A
N S
T
Y P
IC
A
L M
O U
N T
IN
G
H E
IG
H
T S
B
A R
R
IE
R -F
R E
E M
O U
N T
IN
G
H E
IG
H
T S
A N
D A
C C
E S
S O
R Y
M A
T R
IX
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
KEYED NOTES - ENLARGED PLAN
1 18" VERTICAL STAINLESS STEEL GRAB BAR
3 36" STAINLESS STEEL GRAB BAR
4 42" STAINLESS STEEL GRAB BAR
5 TOILET PAPER DISPENSER
6 SANITARY NAPKIN DISPOSAL
7 TOILET PARTITION
8 URINAL SCREEN - HEAVY DUTY CONTINUOUS BRACKET FULL SCREEN HEIGHT
9 SOAP DISPENSER
10 PAPER TOWEL (FOLDED) DISPENSER
11 HAND DRYER
12 STAINLESS STEEL FRAMED MIRROR (18"Wx34"H)
13 SANITARY NAPKIN DISPENSER
14 BABY CHANGING STATION
15 FLOOR MOUNTED SHOWER BENCH
16 STAINLESS STEEL FRAMED MIRROR (18"Wx64"H)
17 SHOWER ROD AND CURTAIN
19 DOUBLE ROBE HOOK
1/2" = 1'-0"
TYPICAL MOUNTING HEIGHTS
1/2" = 1'-0"
TYPICAL BARRIER-FREE MOUNTING HEIGHTS
ACCESSORY MATRIX
DESCRIPTION OP OI CP CI NIC
BABY CHANGING STATIONS X X
CODE REQUIRED INTERIOR SIGNAGE (ALL TOILET ROOMS, STAIRS, RAMPS,
ELEVATORS, ELEVATOR SPRINKLER SHUT-OFF VALVE, AREAS OF REFUGE, TWO-WAY
COMMUNICATION IN AREA OF REFUGE AND ASSEMBLY OCCUPANT LOADS )
X X
GRAB BARS X X
HAND DRYERS X X
MIRRORS X X
SANITARY NAPKIN DISPENSER X
SANITARY NAPKIN DISPOSAL X X
TOILET TISSUE DISPENSERS X X
PAPER TOWEL DISPENSERS X X
WASTE BASKETS X
APPLIANCES X
ARTWORK X
CLOCKS X
COAT HOOKS X X
COPY/PRINTER/FAX X
FURNITURE (AND ASSOCIATED FURNITURE COMPONENTS) X
LOOSE FURNITURE - SEATING, FILE CABINETS, TABLES, ETC. X
SIGNAGE (INTERIOR/EXTERIOR) UNLESS SPECIFIED OTHERWISE IN LEASE X
TIME CLOCK X
TV OR MONITOR BRACKETS FOR WALL OR CEILING MOUNTING X
TVS OR MONITORS (WALL OR CEILING HUNG) X
WINDOW TREATMENTS X X
BLOOD PRESSURE CUFF HOLDERS X
CHART RACKS, LITERATURE RACKS, MAGAZINE RACKS X
GLOVE BOX HOLDERS X
HAND SANITIZER DISPENSERS X
SOAP DISPENSER NO X X
1/4" = 1'-0"A 421
1 ENLARGED WOMEN'S SHOWER AND RESTROOM
1/4" = 1'-0"A 421
3 ENLARGED MEN'S RESTROOM
1/4" = 1'-0"A 421
2 ENLARGED MEN'S SHOWER AND RESTROOM
1/4" = 1'-0"A 421
4 ENLARGED WOMEN'S RESTROOM
1 1/2" = 1'-0"A 421
5 LOCKER WITH BARRIER-FREE SOLID SURFACE BENCH
1/2" = 1'-0"A 421
6 TYP. SHOWER PARTITION ELEVATION
NFGF
(M
A X)
S E E S
C H E D U
LE
SEE SCHED.
8" 8"
S E E S
C H E D U
LE
SEE SCHED.
8"8"
S E E S
C H E D U
LE
SEE SCHED.
SEE SCHED. 2"
S E E S
C H E D U
LE
/8
1' - 9 1/2"
TYP. EXT. WINDOW
ILG-1
10' - 0"
0VERHEAD DOOR 'A'
4' - 0"
1' - 9" 1' - 9"
TYP.
2"
TY
P
BORROWED LITE @ ROOM 210
S-1
A 501
Sim
LG-1 LG-1
STOREFRONT @ VESTIBULE 212
5' - 0"
1' - 6"
2"
2" SEE SCHED.
METAL STUDS
AT 16" O.C.
5/8" GYPSUM
BOARD, BOTH
SIDES HOLLOW METAL
FRAME - REFER
TO SCHEDULE
SEALANT AT
PERIMETER,
BOTH SIDES
5/8" GYPSUM BOARD,
BOTH SIDES
METAL STUDS AT
16" O.C.
METAL STUD
DOUBLE HEADER
BULKHEAD/CEILING LINE -
REFER TO REFLECTED
CEILING PLANS
HOLLOW METAL FRAME -
REFER TO SCHEDULE
CONCRETE MASONRY
UNIT - REFER T0
PLANS
LINTEL - REFER TO
STRUCTURAL
HOLLOW METAL
FRAME - REFER TO
SCHEDULE
PAINT (TYPICAL)
SEALANT AT
PERIMETER,
BOTH SIDES
ROOM SIDE CORRIDOR SIDE
MASONRY SOAPS
BOTH SIDES
ALTERNATE WALL LOCATION -
REFER TO FLOOR PLANS
CONCRETE MASONRY
UNIT WALL - REFER TO
FLOOR PLANS
BULLNOSE (TYPICAL)
SEALANT AT PERIMETER, BOTH
SIDES
HOLLOW METAL FRAME - REFER
TO SCHEDULE - GROUT SOLID
WITH 3 TIES PER JAMB
ROOM SIDE
CORRIDOR SIDE
HOLLOW METAL
FRAME - REFER
TO SCHEDULE
SEALANT AT
PERIMETER,
BOTH SIDES
METAL STUDS
AT 16" O.C.
5/8" GYPSUM
BOARD, BOTH
SIDES
GLAZING KEY
LAMINATED GLASSLG-1
FIRE - PROTECTED GLASSFPG-1
FIRE - RESISTING GLASSFPG-2
INSULATED LAMINATED GLASSILG-1
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
D O
O R
S C
H E
D U
L E
S
A C
C E
S S
P A
N E
L
IN
F O
R M
A T
IO
N
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
DOOR SCHEDULE - FIRST FLOOR
NUMBER
ROOM NAME
FIRE RATING DOOR SIZE FRAME DETAILS
GLASS
ACCESS CONTROLS
HDWR.
SET
REMARKS
DOOR ROOM DOOR FRAME TYPE MAT FIN WIDTH HEIGHT ELEV MAT FIN HEAD JAMB SILL A-PHONE
BARRIER-
FREE
CARD
READER
ELEC. LOCK
HDWR. MAG HOLD
100A 100 STORAGE - - F AL PREFIN 3' - 0" 7' - 2" 1 AL PREFIN - - - - No No No No No - -
100B 100 STORAGE 10' - 0" 12' - 0"
100C 100 STORAGE 20 MIN. 20 MIN. F - PREFIN 6' - 0" 7' - 10" 1 HM P-2 - - - - No No No No No - -
100E 100 STORAGE 90 MIN. 90 MIN. N HM P-2 6' - 0" 7' - 2" 1 HM P-2 - - - FRG-2 No No No No No - -
111 111 WOMENS TOILET 20 MIN. 20 MIN. F HM P-2 3' - 0" 7' - 10" EX EX P-2 - - - - No No No No No - -
115 115 CLASSROOM 90 MIN. 90 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - FRG-2 No No No No No - -
116 116 JAN 45 MIN. 45 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - FPG-1 No No No No No - -
117 117 AV STORAGE - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
120 121 MENS TOILET - - F HM P-2 3' - 0" 7' - 10" - HM P-2 - - - - No No No No No - -
128 128 BREAK ROOM 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
129 129 SIPR 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
130 130 MAIL 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No Yes No No No - -
131 131 FAMILY - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
132 132 LAC - - F HM P-2 3' - 4" 7' - 2" - HM P-2 - - - - No No No No No - -
133A 133 WORKOUT ROOM - - EX EX EX 3' - 0" 7' - 10" - EX. HM EX - - - - No No No No No - INSTALL NEW HARDWARE ON EXISTING DOOR
133B 133 WORKOUT ROOM - - EX EX EX 3' - 0" 7' - 10" - EX. HM EX - - - - No No No No No - INSTALL NEW HARDWARE ON EXISTING DOOR
200A 200 VESTIBULE - - FG EX. AL PREFIN 3' - 0" 7' - 10" - EX. AL PREFIN - - - EX No No Yes Yes No - REINSTALL EXIST. ALUM. DOOR AND FRAME
200B 200 VESTIBULE - - FG EX. AL PREFIN 3' - 0" 7' - 10" - EX. AL PREFIN - - - EX No No No No No - REINSTALL EXIST. ALUM. DOOR AND FRAME
100D 201 CORRIDOR 90 MIN. 90 MIN. N HM PREFIN 7' - 0" 7' - 10" - HM P-2 - - - FRG-2 No No No No No - -
201A 201 CORRIDOR - - FG EX. AL PREFIN 3' - 0" 7' - 10" - EX. AL PREFIN - - - EX No No No No No - REINSTALL EXIST. ALUM. DOOR AND FRAME
201B 201 CORRIDOR - - FG EX. AL PREFIN 3' - 0" 7' - 10" - EX. AL PREFIN - - - EX No No No No No - REINSTALL EXIST. ALUM. DOOR AND FRAME
202A 202 PES 200 UNIFORM STORAGE - - F AL PREFIN 3' - 0" 7' - 2" 1 AL PREFIN - - - - No No No No No - -
202B 202 PES 200 UNIFORM STORAGE 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
204 204 VAULT 2 HR 2 HR EX EX PREFIN 4' - 0" 7' - 2" - EX P-2 - - - - No No No No No EX REINSTALL EXIST. ALUM. DOOR AND FRAME. 180 DEGREE SWING
205A 205 SUPPLY ROOM 20 MIN. 20 MIN. F HM P-2 6' - 0" 7' - 2" 1 HM P-2 - - - - No No No No No - -
210 210 SUPPLY OFFICE - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
212 212 VESTIBULE - - FG AL PREFIN 3' - 0" 7' - 10" - AL PREFIN - - - ILG-1 No No Yes Yes No - -
205B 213 CORRIDOR 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
213A 213 CORRIDOR - - FG AL PREFIN 3' - 0" 7' - 10" - AL PREFIN - - - LG-1 No No No No No - -
213B 213 CORRIDOR 90 MIN. 90 MIN. N HM P-2 3' - 4" 7' - 2" - EX. HM P-2 - - - FPG-1 No No No No No - -
220A 213 CORRIDOR 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No Yes Yes No - 180 DEGREE SWING
214 214 CONFERENCE 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
215 215 OFFICE 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
216 216 VESTIBULE 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
217 217 1 SARGENT - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
218 218 COMMANDER - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
219 219 LEARNING 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
100F 220 CORRIDOR 90 MIN. 90 MIN. N HM P-2 3' - 0" 7' - 10" - HM P-2 - - - FPG-1 No No No No No - -
221 221 PLATOON - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
222 222 PLATOON - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
223 223 VESTIBULE 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
224 224 STORAGE - - F HM P-? 3' - 0" 7' - 2" 1 HM P-? - - - - No No No No No - -
225 225 SUPPLY - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
226 226 ADMINISTRATION - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
227 227 GENERAL OFFICE 20 MIN. 20 MIN. N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
228 228 READINESS - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
229 229 TRAINING - - N HM P-2 3' - 0" 7' - 2" 1 HM P-2 - - - LG-1 No No No No No - -
1/4" = 1'-0"
DOOR PANEL ELEVATION LEGEND
1/4" = 1'-0"
FRAME ELEVATION LEGEND
FRAME ELEVATIONS
1 1/2" = 1'-0"A 501
J-1 JAMB DETAIL
1 1/2" = 1'-0"A 501
H-1 HEAD DETAIL
1 1/2" = 1'-0"A 501
H-2 HEAD DETAIL
1 1/2" = 1'-0"A 501
J-2 JAMB DETAIL
1 1/2" = 1'-0"A 501
S-1 STUD WALL SILL DETAIL
UP
DN
FINISH PLAN KEY
VCT CPT
WALL FINISH
FLOOR BASE
FLOOR FINISH
COUNTER FINISH
CABINET FINISH (BASE AND UPPER)
INDICATES EXTENT OF ATYPICAL FINISH
INDICATES FLOOR MATERIAL TRANSITION
NOTE - REFER TO MATERIAL SELECTION SCHEDULE
REMARKS FOR FLOOR TRANSITION TYPE
REFER TO MATERIAL SELECTION
SCHEDULE FOR FINISH INFORMATION
PL-#
PL-#
P-#
RB-#
CPT-#
P-#
INDICATES MULTIPLE MATERIAL TYPES ON A SURFACE.
REFER TO DETAIL OR ELEVATIONS.
INDICATES MATERIAL PATTERN. REFER TO DETAILS
MULTI
- P
GENERAL NOTES - INTERIORS
1. REFER TO ARCHITECTURAL FLOOR PLANS AND SPECIFICATION FOR ADDITIONAL
INFORMATION ON CONSTRUCTION MATERIALS.
2. REFER TO ARCHITECTURAL FLOOR PLANS FOR VISUAL DISPLAY BOARD LOCATIONS
AND QUANTITIES.
3. REFER TO ARCHITECTURAL FLOOR PLANS FOR LOCKER LOCATIONS, FINISHES AND
QUANTITIES.
4. REFER TO REFLECTED CEILING PLANS FOR CEILING FINISH AND HEIGHTS.
5. REFER TO ENLARGED STAIR PLANS AND SECTIONS FOR FINISH COLORS OF STRINGERS
AND GUARDRAILS.
6. REFER TO DOOR SCHEDULE FOR FINISH ON DOORS AND FRAMES.
7. REFER TO ENLARGED FINISH PLANS FOR TOILET ROOM FINISHES.
8. FINISH TAGS APPLY TO LIKE MATERIALS IN ENTIRE ROOM. I.E. CASEWORK TAG MAY
ONLY CALLOUT ONE RUN OF CASEWORK, BUT ALL CASEWORK IN ROOM RECEIVE THE
SAME FINISHES, UNLESS TAGGED DIFFERENTLY.
9. WALL MOUNTED DIFFUSERS, GRILLES, ACCESS PANELS, ELECTRICAL PANELS, ETC. ARE
TO BE PAINTED WITH AN OIL-BASED PAINT TO MATCH THE ADJACENT WALL FINISH.
10. CEILING ACCESS PANELS ARE TO BE PAINTED TO MATCH ADJACENT CEILING FINISH.
11. ALL EXPOSED COLUMNS TO BE PAINTED P-1.
12. ALL WALLS SHOULD BE PAINTED TO THE FLOOR IN ROOMS WHERE NO BASE IS
INDICATED
FLOORING DIRECTIONAL ARROW
CEMENT PARGING COAT ON CEILING AND EXPOSED
WALLS OF VAULT, PRIME AND PAINT
PRIME AND PAINT WALL SURFACE WHERE
INDICATED WITH DASHED LINES
TRAINING
READINESS
ADMINISTRATION
SUPPLY
GENERAL
OFFICE
VESTIBULE
STORAGE
PLATOON
PLATOON
OFFICE
CORRIDOR
CONFERENCE
VAULT
SUPPLY OFFICE
1 SARGENT
COMMANDER
CHAIR TABLE
STORAGE
WORKOUT
ROOM
NBC
TA 50 / OFFICE
PLATOON 1
PLATOON 2
PLATOON 3
COMM
CORRIDOR
SUPPLY ROOM
TOILET
CLOSET
ASSEMBLY
HALL
CLASSROOM
RECRUIT
SIPR
129MAIL
P-1
RB-1
SC-1
P-1
SC-1
SC-1
P-1
RB-1
CPTL-2
P-1
RB-1
CPTL-2
P-1
RB-2
LVT-2
P-1
RB-1
CPTL-2
P-1
RB-1
VCT-1
P-1
RB-2
LVT-2
SCULLERY
HOT FOOD
PREP
COLD FOOD
PREP
MESS OFFICE
BREAK ROOM
CLOSET
WOMENS
TOILET
P-1
RB-1
SC-1
P-1
RB-1
SC-1
P-1
RB-1
SC-1
P-1
RB-1
SC-1
P-1
RB-1
SC-1
P-1
RB-1
SC-1
P-1
RB-1
SC-1
P-1
RB-1
SC-1
P-1
RB-1
SF-1
P-1
RB-1
SC-1
P-1
RB-1
SC-1
P-1
RB-2
LVT-1
P-1
RB-1
SC-1
P-1
RB-1
CPTL-1
P-1
RB-1
SC-1
P-1
RB-1
ECPTL-1
P-1
RB-1
CPTL-2
P-1
RB-1
CPLT-3
VESTIBULE
REMOVE & REINSTALL
CARPET TILE AT NEW WALL
P-1
RB-2
LVT-1
P-1
RB-1
CPTL-1
P-1
RB-1
CPTL-1
P-1
RB-1
CPTL-2
P-1
RB-1
CPTL-2
P-1
RB-1
CPTL-2
P-1
RB-1
CPTL-2
P-1
RB-1
CPTL-2
P-1
RB-1
CPTL-2
P-1
RB-1
CPTL-2
P-1
RB-1
CPTL-2
P-1
RB-1
CPTL-2
P-1
RB-1
CPTL-2
CORRIDOR
MEN'S
RESTROOM
MENS TOILET
JAN
AV STORAGE
MEN'S
SHOWER
CLASSROOM
PLATOON 2
PLATOON 2
A 631
A 631
A 631
LAC
STORAGE
PES 200
UNIFORM
STORAGE
RECRUIT
VESTIBULE
E X
P T
PT EX EX PT
S C
V C
T
S C
C P T L
S C
C P T L
SSM-1
PL-1
SSM-1
PL-1
SSM-1
PL-1
A 631
SUPPLY OFFICE
FAMILY
LEARNING
LVT EX
C P T
LV
T
SC CPTL
SC ECPTL
SC ECPTL
WOMENS
TOILET
A 631
A 631
S C
C P T L
VESTIBULE
A 621
A 621
A 621
P-2
RBST-1
S C
R B S T
VCT EX
LV
T
S C
EX SF
EX SF
BOILER ROOM
SERVICE
OFFICE
SERVICE
PARTS / TOOLS
BUILDING
MAINTENANCE
PAINT SOFFIT & BULKHEAD WITH P - 1.
REFER TO A201
PAINT SOFFIT & BULKHEAD WITH P - 1.
REFER TO A201
PAINT SOFFIT & BULKHEAD WITH P - 1.
REFER TO A201
PAINT SOFFIT & BULKHEAD WITH P - 1.
REFER TO A201
P-1
RB-1
SC-1
NOT FOR CONSTRUCTION
PRELIM
IN
ARY
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
F
IR
S T
F L
O O
R F
IN
IS
H P
L A
N
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
MIDLAND ARMORY
KEY PLAN
E
A A
C
DB
SCALE: NO SCALE
EXISTING
NEW
BCD
F G
H
I
1/8" = 1'-0"
UPPER AND LOWER FLOOR FINISH PLAN
GENERAL NOTES:
- NO COMPARABLE PRODUCTS WILL BE REVIEWED FOR PRODUCTS DESIGNATED AS SINGLE SOURCE.
- COMPARABLE PRODUCTS WILL BE REVIEWED FOR ITEMS LISTED AS BASIS OF DESIGN. COMPARABLE PRODUCTS ARE REQUIRED TO MEET ANY MINIMUM PERFORMANCE REQUIREMENTS LISTED IN REMARKS AND DESIGN ATTRIBUTES OF SPECIFIED PRODUCT.
- REFER TO PRODUCT SPECIFICATION FOR TRIMS AND ACCESSORIES ASSOCIATED WITH SPECIFIED PRODUCTS ABOVE.
PORCELAIN TILE TO CARPET TILE
PORCELAIN TILE
THINSET OR MORTAR
SCHLUTER RENO-TK - FINISH (FINISH CODE)
LUXURY VINYL TILE TO CARPET TILE
LUXURY VINYL TILE
CARPET TILE
JOHNSONITE SLIMLINE TRANSITION, 63 BURNT UMBER
CARPET TILE TO SEALED CONCRETE
CARPET TILE
SEALED CONCRETE
JOHNSONITE REDUCERS TRANSITION, SSR
VCT TO CARPET TILE
VCT
CARPET TILE
JOHNSONITE SLIMLINE TRANSITION, SLT 63 A
LUXURY VINYL TILE TO SEALED CONCRETE
LVT
SEALED CONCRETE
JOHNSONITE REDUCERS TRANSITION, SSR
RUBBER SPORTS FLOOR TO SEALED CONCRETE
RUBBER SPORTS FLOOR
SEALED CONCRETE
JOHNSONITE REDUCERS TRANSITION, SSR
CARPET TILE TO RUBBER SPORTS FLOOR
CARPET TILE
SPORTS FLOOR
JOHNSONITE T-MOULDING TRANSITION
SCHLUTER QUADEC - GREY (G), GROUT FILL
VOID
WING WALL OR
OUTSIDE CORNER
THINSET OR MORTAR
PORCELAIN OR
CERAMIC TILE, TYP.
WALL TILE OUTSIDE CORNERPORCELAIN TILE WALL BASE AT TILED WALLS
CUT PORCELAIN TILE BASE
SCHLUTER DILEX-EKE
PORCELAIN FLOOR TILE -
REFER TO SPECIFICATIONS
SCHLUTER QUADEC - SATIN NICKEL ANODIZED (AT)
GROUT FILL VOID
CERAMIC OR PORCELAIN WALL TILE
PORCELAIN TILE WALL BASE AT GYPSUM
BOARD WALLS IN RESTROOMS
CUT PORCELAIN TILE BASE
SCHLUTER DILEX-EKE
PORCELAIN FLOOR TILE -
REFER TO SPECIFICATIONS
SCHLUTER QUADEC - SATIN NICKEL ANODIZED (AT)
GROUT FILL VOID
PAINTED GYPSUM BOARD WALL PER FINISH PLAN
SOLID SURFACE COUNTERTOP PER
SCHEDULE - MITERED AT APRON, TYP.
SINK, COORDINATE WITH
PLUMBING
PLASTIC LAMINATE FACED KNEEGUARD & END
PANELS
MIRRORS, REFER TO ELEVATION
REFER TO FINISH PLANS FOR WALL FINISH
INFORMATION
8"
M
A X.
24"
11"
M
IN
SOLID SURFACE AND TOP APRON
VANITY DETAIL
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
M A
T E
R
IA
L S
E L E
C T
IO
N
S C
H E
D U
L E
T
Y P
IC
A
L D
E T
A
IL
S
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
MATERIAL SELECTION SCHEDULE
ABBREV ITEM MANUFACTURER PATTERN COLOR PRODUCT NO. SIZE
SINGLE
SOURCE
BASIS OF
DESIGN
ADDITIONAL
MANUFACTURERS
REMARKS
ACP-1 ACOUSTIC CEILING PANEL ARMSTRONG LYRA PB VECTOR WHITE 8495PB 24" X 48" X USG, HUNTERDOUGLAS, ROCKFON --
CPTL-1 CARPET TILE SHAW CONTRACT HYPE TILE MAGNIFY 64530 5T065 24X24 X .099" THICK | 1/4 TURN INSTALLATION
CPTL-2 CARPET TILE SHAW CONTRACT CITY CENTRAL TILE METRO 72530 5T175 9X36 X ASHLAR INSTALLATION METHOD
CT-1 CERAMIC TILE CROSSVILLE COLOR BY NUMBERS SEVENTH INNING STRETCH CRVWT0748G 4"X8" X CERAMIC FIELD - GLOSSY | HALF BOND INSTALLATIO, GROUT: MAPEI AVALANCHEN
CTB-1 CERAMIC TILE BASE CROSSVILLE COLOR BY NUMBERS SEVENTH INNING STRETCH 4" X12" X BULLNOSE GLOSS | TO BE APPLIED ON PAINTED WALLS
ECPTL-1 ENTRYWAY CARPET TILE SHAW CONTRACT BON JOUR II TILE STERLING 31557 5T032 24" X 24" X 1/4 TURN INSTALLATION
EP-1 EXPOXY PAINT BEHR TO MATCH P-1 TO MATCH P-1 X SHERWIN WILLIAMS, BENJAMIN MOORE
LVT-1 LUXURY VINYL TILE INTERFACE STUDIO SET A00726 PEBBLE A007 25 cm X 1m X 4.5 MM THICK | ASHLAR INSTALLATION METHOD
LVT-2 LUXURY VINYL TILE INTERFACE STARGAZING SCORPIO A01713 PEBBLE A017 50cm x 50cm X ASHLAR INSTALLATION METHOD
P-1 PAINT BEHR -- WHITE 52 -- X SHERWIN WILLIAMS, BENJAMIN MOORE --
P-2 PAINT SHERWIN WILLIAMS -- CAVIAR SW 6990 X BENJAMIN MOORE, BEHR HOLLOW METAL DOOR FRAMES
PL-1 PLASTIC LAMINATE FORMICA -- PLATINUM 902-58 -- X MATTE FINISH PLATINE
PT-1 PORCELAIN TILE ANATOLIA ASPEN BEACHCOMBER ANAASBE636R 6"X36" X 1/3 BOND INSTALLATION, GROUT: MAPEI PEWTER
RB-1 RUBBER BASE TARKETT -- BLACK 40 4" X ROPPE, FLEXCO TYPICAL WALLBASE
RB-2 RUBBER BASE TARKETT -- MOON ROCK 29 4" X ROPPE, FLEXCO TYPICAL WALLBASE IN CLASSROOM AND BREAKROOM
RBST-1 RUBBER STAIR TREAD TARKETT ANGLE FIT RUBBER STAIR TREADS BLACK 40 X STYLE HAMMERED
SC-1 SEALED CONCRETE REFER TO CONCRETE SPECIFICATION
SF-1 SPORT FLOORING CAPRI COLLECTIONS FITNESS & REC ROCK BOTTOM RTL4035 4' ROLL WIDTH, 8MM THICKNESS X
SSM-1 SOLID SURFACE CORIAN -- GLACIER WHITE -- -- X
VCT-1 VINYL COMPOSITION TILE TARKETT TARKETT VCT II SANDSTONE 556 12" X 12" X
3" = 1'-0"A 611
2 FLOORING TRANSITIONS
3" = 1'-0"A 611
3 TYPICAL TILE DETAILS
1 1/2" = 1'-0"A 611
1 TYPICAL VANITY SECTION
301303 304OFFICE18 19
A 6212H
A 621
2C
2A
2B2D
A 621
2G
A 621
2E
EP-1
PT-1
PT-1
C T -1
C T -1
C T -1
C T -1
C T -1
C T -1
C T -1
C T -1
C T -1
C T -1
CT-1
SS-1
PL-1
EP-1
PT-1
PT-1
CT-1
PT-1
PT-1
EP-1
CTB-1
PT-1
SS-1
PL-1
MEN'S
SHOWER
MEN'S
RESTROOM
MEN'S LOCKER
MENS TOILET
C T -1
C T -1
C T -1
C T -1
C T -1
CT-1
36"
25"
2F
A 6213A 3B
CT-1
CT-1
PT-1
WOMENS
TOILET
A 6211D 1C
A 621
1B
EP-1
PT-1
PT-1
EP-1
PT-1
PT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
C T -1
CT-1
CT-1
CT-1
WOMENS
TOILET
1A
A 4216
WOMEN'S
SHOWERS
CT-1CT-1
SSM-1
PL-1
SSM-1
3 7/8"4 1/4" 36" 10 1/8" 35 1/8" 8 1/2" 36 3/4" 4 7/8"
TILE BEGINS ABOVE
SHOWER WALL 74" AFF,
TYPICAL
36" 9 1/4" 36" 9 1/4" 36" 9 1/4" 36" 4 5/8"
176 3/8"
TILE BEGINS ABOVE
SHOWER WALL 74" AFF,
TYPICAL
36"36"
FP
1"
6' - 1"
4 1/4" 36" 9 1/4" 36" 9 1/4" 36" 9 1/4" 36" 9 1/4" 36" 9 1/4" 36" 4 5/8"
266 7/8"
TILE BEGINS ABOVE
SHOWER WALL 74" AFF,
TYPICAL
OPEN
TILE BEGINS ABOVE
SHOWER WALL 74"
AFF, TYPICAL
36" 145 3/8" 36 5/8"
218"
4 5/8" 36" 9 1/4" 36" 9 1/4" 36" 9 1/4" 36" 9 1/4" 36" 9 1/4" 36"
266 7/8"
TILE BEGINS ABOVE
SHOWER WALL 74" AFF,
TYPICAL
TILE BEGINS ABOVE
SHOWER WALL 74" AFF,
TYPICAL
36"
45 1/8" 40 7/8" 36"60"
96"
11 1/2" 18"
11 1/2"
/2
216" 14" 18" 14" 18" 14"
132"
T O
C O
N T R O
LS
14 7/8"
T O
W O
R K S
U R F A C E
72"
18"
/2
T O
C O
N T R O
LS
T O
C O
N T R O
LS
M
A X
60"
CONTINUOUS
PTD LEDGER
SUPPORT
BRACKETS
72" 24"
/2
GENERAL NOTES - CASEWORK
STANDARD ABBREVIATIONS FOR CASEWORK
ADJ ADJUSTABLE
FP FILLER PANEL
RP REMOVABLE PANEL
1. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO FABRICATION.
2. FILLER PANELS SHALL BE NO LESS THAN 2" WIDE, UNLESS NOTED OTHERWISE.
3. REFER TO FLOOR FINISH PLANS FOR CASEWORK AND COUNTERTOP FINISHES BY
ROOM.
4. FINISH ANY EXPOSED END PANELS, UNDERSIDE OF CABINETS OR OPEN CABINETS,
WITH PLASTIC LAMINATE SPECIFIED FOR FRONTS IN THAT ROOM.
5. ALL VERTICAL AND HORIZONTAL EXPOSED AND SEMI-EXPOSED SURFACES
TO BE FINISHED WITH BODY PLASTIC LAMINATE.
6. SUPPORT BRACKETS ARE REQUIRED EVERY 36" O.C. AT AREAS WHERE COUNTERTOP
IS OPEN UNDERNEATH. THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING
BRACKETS APPROPRIATELY SIZED BASED ON DEPTH OF COUNTER.
7. PATTERN OR GRAIN DIRECTION TO BE VERTICAL ON DOORS AND HORIZONTAL ON
DRAWERS - PER AWI STANDARDS, UNLESS NOTED OTHERWISE.
8. GROMMET LOCATIONS SHALL BE VERIFIED IN THE FIELD WITH THE OWNER PRIOR TO
INSTALLATION - COORDINATE WITH POWER & DATA LOCATIONS FOR ANY ADDITIONAL
WIRE MANAGEMENT REQUIREMENTS
9. 'SLABSMITHING' WILL BE REQUIRED IN INSTANCES WHERE A PATTERNED QUARTZ,
NATURAL STONE, OR SOLID SURFACE IS SPECIFIED.
ENLARGED FINISH PLAN KEY
VCT CPT
WALL FINISH
FLOOR BASE
FLOOR FINISH
COUNTER FINISH
CABINET FINISH (BASE AND UPPER)
INDICATES EXTENT OF ATYPICAL FINISH
INDICATES FLOOR MATERIAL TRANSITION
NOTE - REFER TO MATERIAL SELECTION SCHEDULE
REMARKS FOR FLOOR TRANSITION TYPE
REFER TO MATERIAL SELECTION
SCHEDULE FOR FINISH INFORMATION
PL-#
PL-#
P-#
RB-#
CPT-#
P-#
INDICATES MULTIPLE MATERIAL TYPES ON A SURFACE.
REFER TO DETAIL OR ELEVATIONS.
INDICATES MATERIAL PATTERN. REFER TO DETAILS
MULTI
- P
GENERAL NOTES - ENLARGED FINISH PLANS
1. REFER TO ARCHITECTURAL FLOOR PLANS AND SPECIFICATION FOR ADDITIONAL
INFORMATION ON CONSTRUCTION MATERIALS.
2. REFER TO ARCHITECTURAL FLOOR PLANS FOR VISUAL DISPLAY BOARD LOCATIONS
AND QUANTITIES.
3. REFER TO ARCHITECTURAL FLOOR PLANS FOR LOCKER LOCATIONS, FINISHES AND
QUANTITIES.
4. REFER TO REFLECTED CEILING PLANS FOR CEILING FINISH AND HEIGHTS.
5. REFER TO DOOR SCHEDULE FOR FINISH ON DOORS AND FRAMES.
6. REFER TO MATERIAL SELECTION SCHEDULE FOR FINISH INFORMATION.
7. FINISH TAGS APPLY TO LIKE MATERIALS IN ENTIRE ROOM. I.E. CASEWORK TAG MAY
ONLY CALLOUT ONE RUN OF CASEWORK, BUT ALL CASEWORK IN ROOM RECEIVE THE
SAME FINISHES, UNLESS TAGGED DIFFERENTLY.
8. WALL MOUNTED DIFFUSERS, GRILLES, ACCESS PANELS, ELECTRICAL PANELS, ETC. ARE
TO BE PAINTED WITH AN OIL-BASED PAINT TO MATCH THE ADJACENT WALL FINISH.
9. CEILING ACCESS PANELS ARE TO BE PAINTED TO MATCH ADJACENT CEILING FINISH.
10. ALL EXPOSED COLUMNS TO BE PAINTED P-1.
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
E N
L A
R G
E D
T O
IL
E
T R
O O
M F
IN
IS
H P
L A
N S
A N
D E
L E
V A
T
IO
N S
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
1/4" = 1'-0"A 621
2 MENS ENLARGED TOILET ROOM FINISH PLAN
1/4" = 1'-0"A 621
3 WOMENS 123 ENLARGED TOILET ROOM FINISH PLAN
1/4" = 1'-0"A 621
WOMENS TOILET 111 AND WOMENS SHOWERS 112
ENLARGED TOILET ROOM FINISH PLAN
1/4" = 1'-0"A 621
1C WOMEN'S SHOWER 112 - EAST
1/4" = 1'-0"A 621
1D WOMEN'S SHOWER 112 - WEST
1/4" = 1'-0"A 621
1B WOMEN'S RESTROOM 111 - SOUTH
1/4" = 1'-0"A 621
2A MEN'S SHOWER 118 - NORTH
1/4" = 1'-0"A 621
2B MEN'S SHOWER 118 - EAST
1/4" = 1'-0"A 621
2C MEN'S SHOWER 118 - SOUTH
1/4" = 1'-0"A 621
2D MEN'S SHOWER 118 - WEST
1/4" = 1'-0"A 621
2G MEN'S RESTROOM 120 - NORTH
1/4" = 1'-0"A 621
2E MEN'S LOCKER 119 - SOUTH
1/4" = 1'-0"A 621
2H MEN'S TOILET 121 - WEST
1/4" = 1'-0"A 621
3B WOMEN'S TOILET - EAST
1/4" = 1'-0"A 621
3A WOMEN'S TOILET - WEST
1/4" = 1'-0"A 621
1A WOMEN'S TOILET 111 - NORTH
1/4" = 1'-0"A 621
2F MEN'S LOCKER 119 - EAST
33" 33" 33"
FP
101"
36" 36"
FP
EQ. EQ.
PLASTIC LAMINATE FINISH, PL-1
72 3/4"
48"
FP42"FP
MOUNTED ON
EXSISTING BRICK
WALL
/8
/8
/2 "7
61"
TV, N.I.C.
PROVIDE BLOCKING &
UTILITIES ONLY
61"
TV, N.I.C
PROVIDE BLOCKING &
UILITIES ONLY
GENERAL NOTES - CASEWORK
STANDARD ABBREVIATIONS FOR CASEWORK
ADJ ADJUSTABLE
FP FILLER PANEL
RP REMOVABLE PANEL
1. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO FABRICATION.
2. FILLER PANELS SHALL BE NO LESS THAN 2" WIDE, UNLESS NOTED OTHERWISE.
3. REFER TO FLOOR FINISH PLANS FOR CASEWORK AND COUNTERTOP FINISHES BY
ROOM.
4. FINISH ANY EXPOSED END PANELS, UNDERSIDE OF CABINETS OR OPEN CABINETS,
WITH PLASTIC LAMINATE SPECIFIED FOR FRONTS IN THAT ROOM.
5. ALL VERTICAL AND HORIZONTAL EXPOSED AND SEMI-EXPOSED SURFACES
TO BE FINISHED WITH BODY PLASTIC LAMINATE.
6. SUPPORT BRACKETS ARE REQUIRED EVERY 36" O.C. AT AREAS WHERE COUNTERTOP
IS OPEN UNDERNEATH. THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING
BRACKETS APPROPRIATELY SIZED BASED ON DEPTH OF COUNTER.
7. PATTERN OR GRAIN DIRECTION TO BE VERTICAL ON DOORS AND HORIZONTAL ON
DRAWERS - PER AWI STANDARDS, UNLESS NOTED OTHERWISE.
8. GROMMET LOCATIONS SHALL BE VERIFIED IN THE FIELD WITH THE OWNER PRIOR TO
INSTALLATION - COORDINATE WITH POWER & DATA LOCATIONS FOR ANY ADDITIONAL
WIRE MANAGEMENT REQUIREMENTS
9. 'SLABSMITHING' WILL BE REQUIRED IN INSTANCES WHERE A PATTERNED QUARTZ,
NATURAL STONE, OR SOLID SURFACE IS SPECIFIED.
F
IL
E N
U M
B E
R
S T
A T
E I
N D
E X
N U
M B
E R
S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T
A N
D B
U D
G E
T S
T A
T E
O F
M
IC
H
IG
A N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
IN
T
E R
IO
R
E L
E V
A T
IO
N
S A
N D
S E
C T
IO
N
S
-1
.0
A
J u n e
M
ID
L A
N D
A R
M O
R Y
A D
D
IT
IO
N
A N
D R
E N
O V
A T
IO
N
A
IR
P
O R
T R
O A
D
M
ID
L A
N D
M
I
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
'S A
F F
A
IR
S
/2
.M
A A
/1
/2
/3
/2
1/4" = 1'-0"A 631
1 BREAK ROOM - NORTH
1/4" = 1'-0"A 631
2 MAIL ROOM - NORTH 1/4" = 1'-0"A 631
3 LACTATION ROOM - SOUTH
1/4" = 1'-0"A 631
4 DRINKING AREA
1/4" = 1'-0"A 631
5 CLASSROOM - NORTH
1/4" = 1'-0"A 631
6 CONFERENCE ROOM - NORTH
BRITISH THERMAL UNIT PER HOUR
AUTOMATIC CONTROL DAMPER
BRITISH THERMAL UNIT PER HOUR
CALIBRATED BALANCING VALVE
CUBIC FEET PER MINUTE
ENTERING AIR TEMPERATURE
EXTERNAL STATIC PRESSURE
ELECTRIC WATER COOLER
ENTERING WATER TEMPERATURE
LEAVING AIR TEMPERATURE
LEAVING WATER TEMPERATURE
MIXED AIR TEMPERATURE
FIELD INSTALLEDF.I.
MBH
M.B.
(THOUSANDS)
MOP BASIN
L.A.T.
L.W.B L.W.T.
M.A.
M.A.T.
MAX.
LAV.
L.D.B.
LOUV.
G.P.M.
H.B.
HP
I.E.
F.M.
F.P.M.
F.R.
LAVATORY
LEAVING DRY BULB
LEAVING WET BULB
MIXED AIR
MAXIMUM
LOUVER
FLOOR MOUNTED
FEET PER MINUTE
FIN RADIATION
GALLONS PER MINUTE
HOSE BIBB
HORSE POWER
INVERT ELEVATION
CONTROL VALVEC.V.
F.D.
(FD)
E.W.B.
E.W.C.
E.W.T.
EXIST.
E.A.
E.A.T.
E.D.B.
E.F.
E.S.P.
D.F.
D.S.
DN.
ENTERING WET BULB
FLOOR DRAIN
FIRE DAMPER
EXISTING
DRINKING FOUNTAIN
DOWN SPOUT
EXHAUST AIR
ENTERING DRY BULB
EXHAUST FAN
DOWN
C.H.
C.I.
C.M.
C.O.
C.B.V.
C.F.H.
C.F.M.
B.D.D.
B.F.
BTUH
B.V.
B.D.
A.F.F.
A.G.
A.P.D.
CUBIC FEET PER HOUR
CABINET HEATER
CAST IRON
CEILING…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .