511.21085.MAA_Addendum #1 ALL DOCUMENTS_Part2.pdf

PDF 4 MB Posted

Attached to
511/21085. MAA; Midland Armory Construction
Solicitation number
RFQ - 171 - 230000000626
Issued by
Lenawee County, Michigan

About this file

The document provided is an addendum related to a state and local contract opportunity for the Midland Armory Construction project located in Midland, Michigan. The project involves the addition and renovation of the Midland Armory, which is overseen by the Department of Military and Veteran's Affairs for the State of Michigan. The addendum includes detailed specifications for the exterior wall, roof, and interior finishes, as well as various construction details and drawings. The bid attachments must be uploaded to the SIGMA VSS system, and any questions or issues should be directed to the provided contacts. The response deadline is 2:00 p.m. on an unspecified date.

The contract pricing terms, set-asides, incumbent information, funding sources, and other salient details are not provided in the addendum document. The addendum focuses solely on providing technical information and construction specifications for the project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOWER FLOOR

100' - 0" (X' - X")

TOP MASONRY

117' - 4"

A 321

1A

A 321

1B

WOOD BLOCKING

ALUM EXTRUSION

4" (NOM) BRICK,

MATCH EXISTING

8" CMU

INSULATED ROOF

METAL DECK

3" INSULATION

13/4" AIR SPACE

LOWER FLOOR

100' - 0" (X' - X")

TOP MASONRY

117' - 4"

A 321

2B

A 321

2C

A 321

2A

WOOD BLOCKING

TO REMAIN

EXISTING METAL

FASCIA TO REMAIN

±4" SALVAGED

UTILITY BRICK

4" CMU

STORE FRONT

EXISTING ROOF

TO REMAIN

EXISTING

STRUCTURAL

TO REMAIN

3" INSULATION

± 2 1/4" AIR SPACE

EXISTING STEEL

JOIST

LOWER FLOOR

100' - 0" (X' - X")

TOP MASONRY

117' - 4"

A 321

2A

SIM

EXISTING WOOD

BLOCKING TO REMAIN

EXISTING METAL

FASCIA TO REMAIN

4" UTILITY BRICK,

MATCH EXISTING

4" CMU

EXISTING ROOF

TO REMAIN

EXISTING

STRUCTURAL TO

REMAIN

± 1 1/4" AIR SPACE

EXISTING STEEL

JOIST

NEW FLOST

SLAB, SEE

STRUCTURAL

LOWER FLOOR

100' - 0" (X' - X")

TOP MASONRY

117' - 4"

A 321

4B

A 321

4A

A 321

2A

SIM

EXISTING WOOD

BLOCKING TO REMAIN

EXISTING METAL

FASCIA TO

REMAINFASCIA

4" CMU

INSULATED

PANEL GARAGE

DOOR

EXISTING

STRUCTURAL TO

REMAIN

3" INSULATION

± 2 1/4" AIR SPACE

±4" SALVAGED

UTILITY BRICK

NEW FLOST

SLAB, SEE

STRUCTURAL

LOWER FLOOR

100' - 0" (X' - X")

TOP MASONRY

117' - 4"

A

A 321

5A

A 321

5B

E X

IS

T

IN

G B

R

IC

K /C

M U W

A

LL

T O

R E M

A

IN

/4

/4

±4" SALVAGED

BRICK

4" CMU

3" INSULATION

± 2 1/4" AIR SPACE

E X

IS

T

IN

G

B R

IC

K W

A

LL

T O

R E M

A

IN

E X

IS

T

B R

IC

K W

O

R E M

A

IN

A1

LOWER FLOOR

100' - 0" (X' - X")

TOP MASONRY

117' - 4"

UPPER FLOOR

104' - 0" (X' - X")

A 321

6A

A 321

6B

E X

IS

T

IN

G B

R

IC

K /C

M U W

A

LL

T O

R E M

A

IN

N E W

I N F

IL

L W

A

LL

± 4" SALVAGED

UTILITY BRICK

4" CMU

3" INSULATION

± 2 1/4" AIR

SPACE N

E W

I N F

IL

L W

A

LL

E X

IS

T

IN

G B

R

IC

K /C

M U

W

LL

T O

R E M

A

IN

TOP MASONRY

117' - 4"

UPPER FLOOR

104' - 0" (X' - X")

A 321

7A

A 321

7B

A 321

1A

SIM

/8

/8

WOOD BLOCKING

METAL FASCIA

4" BRICK, MATCH

EXISTING

8" CMU

INSULATED ROOF

METAL DECK

3" INSULATION

1 3/4" AIR SPACE

8" CMU

CEILING, SEE

REFLECTED CEILING

PLAN

CAST STONE SILL

NEW WINDOW

0"

A1

A1

TOP MASONRY

117' - 4"

UPPER FLOOR

104' - 0" (X' - X")

WOOD BLOCKING

METAL FASCIA

BRICK, MATCH

EXISTING

8" CMU

INSULATED ROOF

METAL DECK

3" INSULATION

1" AIR SPACE

GYPSUM BOARD

CEILING, SEE

REFLECTED CEILING

A 321

1A

SIM

A 321

8B

A1

A1

TOP MASONRY

117' - 4"

4" (NOM) BRICK,

MATCH EXISTING

3" RIGID

INSULATION, SEAL

3" INSULATION

1 3/4" AIR SPACE

1' - 1 5/8"

ALUM GRAVEL

STOP PROFILE

AND HEIGHT TO

MATCH EXISTING

1/2" COVER BOARD

5" RIGID INSULATION

METAL DECK, SEE

STRUCTURAL

STEEL JOIST, SEE

STRUCTURAL

EPDM ROOF MEMBRANE

(2) TRT 2X4

STACKED. 24"

O.C. WITH INSUL

BETWEEN

/1

M T A C H E

X

IS

T

/4

EPDM ROOF MEMBRANE

PREBUCK

PARAPET CAP

1' - 7"

/2

3/4" TRT 1X4

STRIPS, 24" O.C.

SEALANT

MESH GROUT STOP

BOND BEAM

A1

LOWER FLOOR

100' - 0" (X' - X")

8" CMU

3" INSULATION

1 3/4" AIR SPACE

10 5/8"

CONCRETE

FOUNDATION

WALL FOOTING,

SEE STRUCTURAL

FLOOR SLAB

1' - 4"

3" RIGID

INSULATION

2" RIGID

INSULATION

CAVITY DRAINAGE

MESH

GROUT SOLID

WEEPS AT 24" O.C.

CONCRETE

APRON, SEE

CIVIL

4" BRICK, MATCH

EXISTING

MEMBRANE

FLASHING

BOND BREAKER

MATERIALA1

4" UTILITY BRICK,

MATCH EXISTING

8" CMU

1" AIR SPACE

LINTEL - REFER

TO STRUCTURAL

SEALANT ON

BOTH FACES

ALUMINUM

DOOR FRAME

CAVITY DRAINAGE

MESH

FLASHING

MEMBRANE

LOWER FLOOR

100' - 0" (X' - X")

THERMALLY BROKEN

ALUMINUM

STOREFRONT DOOR

WITH INSULATED GLASS

DOOR

THRESHOLD

EXISTING

CONCRETE

FOOTING

EXISTING

CONCRETE

FLOOR SLAB

1 3/4" 2" 4"ALUM. SNAP TRIM

AND CLIP

4 3/4"

NEW FROST

SLAB, SEE

STRUCTURAL

OVERHEAD DOOR

OVERHEAD

DOOR TRACK

PAINTED STEEL

TUBE LINTEL AND

PLATE - REFER

TO STRUCTURAL

4" UTILITY BRICK,

MATCH EXISTING

AIR SPACE

8" CMU

WEEPS AT 24"

O.C.

CAVITY DRAINAGE

MESH

LOWER FLOOR

100' - 0" (X' - X")

NEW FLOST

SLAB, SEE

STRUCTURAL

GARAGE

DOOR

EIXSTING

STRUCTURE

BOND BREAKER

MATERIAL

3" RIGID

INSULATION

2" RIGID

INSULATION

A

M

IN

EXISTING UTILITY

VENEER OVER CMU

WALL

5/8" GYPSUM OVER

3 5/8" METAL

STUDS, 16" O.C.

GYPSUM BOARD

CELING, SEE

REFLECTED CEILING

PLAN

A

LI

G N

4" CMU

3" INSULATION

±2 1/4" AIR SPACE

5/8"3 5/8"3 5/8"3"

2 1/4"

3 5/8"

MORTAR JOINT,

MATCH EXISTING

±4" SALVAGED

BRICKA1

LOWER FLOOR

100' - 0" (X' - X")

A

5/8" GYPSUM OVER

METAL STUDS, 16"

O.C., SEE FLOOR

PLAN

EXISTING

FLOOR SLAB

SEALANT

EXISTING UTILITY

VENEER OVER CMU

WALL TO REMAIN

A

LI

G N

4" CMU

3" INSULATION

±2 1/4" AIR SPACE

5/8"3 5/8"3 5/8"3" 2 1/4"

3 5/8"

MORTAR JOINT,

MATCH EXISTING

±4" SALVAGED

BRICK

INFILLE BRICK

VENEER WHERE

SILL IS REMOVED,

MATCH EXISTING

UTILITY BRICK FILL VOID WITH 4"

CMU

FILL WITH MORTAR

EXISTING CMU

WALL(s) TO REMAIN

A1

4" BRICK, MATCH

EXISTING

3" INSULATION

1 3/4 AIR SPACE

8" CMU

TILE CEILING, SEE

REFLECTED

CEILING PLAN

ALUMINUM

WINDOW FRAME

SEALANT BOTH

FACES

MATCH EXIST.

± 8 1/2"

3 5/8"1 3/4" 3" 7 5/8"

1' - 4"

A1

UPPER FLOOR

104' - 0" (X' - X")

4" UTILITY BRICK,

MATCH EXISTING

3" INSULATION

1 3/4" AIR SPACE

8" CMU

ALUMINMUM

WINDOW FRAME

SOLID SURFACE

WINDOW SILL.

SEE FINISH PLAN

ALUMINUM SILL

FLASHING

MEMBRANE

FLASHING.

EXTEND UNDER

WINDOW SUBSILL

CAVITY DRAINAGE

MESH

WEEPS AT 24" O.C.

CAST STONE SILL,

MATCH EXISTING

PROFILE

3 5/8" 1 3/4" 3" 7 5/8"

1' - 4"

± 4" SALVAGED

BRICK

4" CMU

3" INSULATION

± 2 1/4" AIR SPACE

EXISTING

UTILITY BRICK

A

LI

G N

5/8" GYPSUM OVER

3 5/8" METAL

STUDS, 16" O.C.

GYPSUM CEILING

A1

UPPER FLOOR

104' - 0" (X' - X")

± 4" SALVAGED

UTILITY BRICK

4" CMU

3" INSULATION

± 2 1/4" AIR SPACE

EXISTING BRICK

VENEER BELOW

TO REMAIN

3 5/8" 2 1/4"

3" 3 5/8"

INFILLE BRICK

VENEER WHERE

SILL IS REMOVED,

MATCH EXISTING

UTILITY BRICK

FILL VOID

WITH 4" CMU

EXISTING

CONCRETE

SLAB

EXISTING

CMU WALL(s)

TO REMAIN

A

LI

G N

FILL WITH MORTAR

MORTAR JOINT,

MATCH EXISTING

TOP MASONRY

117' - 4"

4" BRICK, MATCH

EXISTING

8" CMU

1" AIR SPACE

EXISTING FASCIA

TO REMAIN

EXISTING WOOD

BLOCK(s) TO REMAIN

EXISTING ROOF

TO REMAIN

EXISTING STEEL

JOIST

EXITING BRICK

ANGLES, REMOVE

AND REINSTALL WITH

WALL CONSTRUCTION

EXISTING STEEL

ANGLE

BRICK TO REMAIN

A1

4" (NOM.) BRICK,

MATCH EXISTING

3" INSULATION

1" AIR SPACE

8" CMU

ALUMINUM

WINDOW

SEALANT ON

BOTH FACES

MORTAR JOINT

CAST STONE SILL, MATCH

DIMENSIONS TO EXISTING

M A T C

H E

X

IS

T

IN

G

/2

SILL FLASHING

UPPER FLOOR

104' - 0" (X' - X")

3" INSULATION

1 3/4" AIR SPACE

CAVITY DRAINAGE

MESH

GROUT SOLID

WEEPS AT 24" O.C.

4" UTILITY BRICK,

MATCH EXISTING

MEMBRANE

FLASHING

2" RIGID

INSULATION

CONCRETE

FOOTING, SEE

STRUCTURAL

BOND BREAKER

MATERIAL

3" RIGID

INSULATION

8" CMU

1 3/4" 3" 7 5/8"3 5/8"

1' - 4"

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

W A

L L

S E

C T

IO

N

S

-1

.0

A

J u n e

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.M

A A

/1

/2

/3

/2

1/2" = 1'-0"A 321

1 WALL SECTION

1/2" = 1'-0"A 321

2 WALL SECTION

1/2" = 1'-0"A 321

3 WALL SECTION

1/2" = 1'-0"A 321

4 WALL SECTION

1/2" = 1'-0"A 321

5 WALL SECTION

1/2" = 1'-0"A 321

6 WALL SECTION

1/2" = 1'-0"A 321

7 WALL SECTION

1/2" = 1'-0"A 321

8 WALL SECTION

1 1/2" = 1'-0"A 321

1A WALL DETAIL

1 1/2" = 1'-0"A 321

1B WALL DETAIL

1 1/2" = 1'-0"A 321

2B WALL DETAIL

1 1/2" = 1'-0"A 321

2C WALL DETAIL

1 1/2" = 1'-0"A 321

4A WALL DETAIL

1 1/2" = 1'-0"A 321

4B WALL DETAIL

1 1/2" = 1'-0"A 321

5A WALL DETAIL

1 1/2" = 1'-0"A 321

5B WALL DETAIL

1 1/2" = 1'-0"A 321

7A WALL DETAIL

1 1/2" = 1'-0"A 321

7B WALL DETAIL

1 1/2" = 1'-0"A 321

6A WALL DETAIL

1 1/2" = 1'-0"A 321

6B WALL DETAIL

1 1/2" = 1'-0"A 321

2A WALL DETAIL

1 1/2" = 1'-0"A 321

7C JAMB DETAIL

1 1/2" = 1'-0"A 321

8B WALL DETAIL

ISSUED FOR DATE

ADDENDUM 1 08-03-2023

LOWER FLOOR

100' - 0" (X' - X")

TOP MASONRY

117' - 4"

A 322

1A

A 321

1A

SIM

A 322

1B

WOOD BLOCKING

METAL FASCIA

4" BRICK, MATCH

EXISTING

4" CMU

INSULATED ROOF

METAL DECK

STOREFRONT

4' - 6 3/8"

3" INSULATION

1" AIR SPACE

3 5/8" METAK STUD,

ADD BRACING AS

NEEDED

3 1/2" INSULATION

NEW FLOST

SLAB, SEE

STRUCTURAL

A1

A1

LOWER FLOOR

100' - 0" (X' - X")

TOP MASONRY

117' - 4"

WOOD BLOCKING

METAL FASCIA

INSULATED ROOF

METAL DECK

DOOR

4' - 6 3/8"

A 322

1A

SIM

A 322

1B

SIM

A 321

1A

SIM

4" BRICK, MATCH

EXISTING

4" CMU

3" INSULATION

1" AIR SPACE

3 5/8" METAL STUD,

ADD BRACING AS

NEEDED

3 1/2" INSULATION

NEW FLOST

SLAB, SEE

STRUCTURAL

A1

A1

LOWER FLOOR

100' - 0" (X' - X")

TOP MASONRY

117' - 4"

A 322

3A

A 322

3B

A 321

1A

SIM

WOOD BLOCKING

METAL FASCIA

4" BRICK, MATCH

EXISTING

8" CMU

INSULATED ROOF

METAL DECK

3" INSULATION

1" AIR SPACE

FROST

CONCRETE

SLAB, SEE

STRUCTURAL

A1

A1

4" UTILITY BRICK,

MATCH EXISTING

8" CMU

3" INSULATION

1" AIR SPACE

STEEL LINTEL,

SEE STRUCTURAL

MEMBRANE

FLASHING

3 5/8" 8"

ALIGN

WEEPS AT

24" O.C.

CAVITY

DRAINAGE MESH

EIFS FINISH OVER

GYPSUM BOARD

SHEATHING (EXTERIOR),

SEE REFLECTED CEILING

PLAN

4" BRICK, MATCH

EXISTING

8" CMU

3" INSULATION

1" AIR SPACE

STEEL LINTEL,

SEE STRUCTURAL

MEMBRANE

FLASHING

CAVITY

DRAINAGE MESH

WEEPS AT 24"

O.C.

SEALANT JOINTS,

BOTH FACES

MATCH EXIST.

A1

LOWER FLOOR

100' - 0" (X' - X")

THERMALLY BROKEN

ALUMINUM

STOREFRONT DOOR

WITH INSULATED GLASS

DOOR

THRESHOLD

CONCRETE

FLOOR SLAB, SEE

STRUCTURAL

ALUM. SNAP TRIM

AND CLIP

CONCRETE

FOUNDATION WALL,

SEE STRUCTURAL

BOND BREAKER

MATERIAL

FROST SLAB,

SEE STRUCTURAL 3" RIGID

INSULATION

2" RIGID

INSULATION

2X WOOD

BLOCKING

1X WOOD

BLOCKING

ALUMINUM

STOREFRONT DOOR

AND FRAMES

SEALANT JOINTS,

BOTH FACES

EIFS FINISH OVER

GYPSUM BOARD

SHEATHING

(EXTERIOR), SEE

REFLECTED CEILING

PLAN

GYPSUM

SHEATHING

BATT

INSULATION,

R-19

GYPSUM BOARD

CEILING, SEE

REFLECTED

CEILING PLAN

LOWER FLOOR

100' - 0" (X' - X")

TOP MASONRY

117' - 4"

T

A 322

4A

P O

R T

IO

N S O

F T

H E W

A

LL

B E C O

M E S N

E W

C M

U T

O R

E P

LA

C E E

X

IS

T

IN

G W

WOOD BLOCKING

INSULATED ROOF

METAL DECK

12" CMU

REMAINING SECTIONS OF

EXISTING CMU WALLS

SHARE SIMILAR DETAIL

REFER TO FLOOR PLAN

A 322

4B

TOP MASONRY PARAPET

120' - 0"

A1

TOP MASONRY

117' - 4"

T

12" (NOM)

CMU INFILL

1 1/2" RGID

INSULATION

RIGID

INSULATION

EPDM MEMBRANE.

1/2" COVER

BOARD

FASCIA TO MATCH

EXISTING ALUM

EXTRUSION (VIF)

EXISTING METAL FASCIA

TO BE REMOVED

EXISTING ROOF

TO REMAIN

EXISTING WOOD

BLOCKS TO REMAIN

CANT STRIP

TOP MASONRY PARAPET

120' - 0"

STRIP-IN NEW ROOFING

MEMBRANE

10 5/8"

A1

MORTAR NET

BOND BEAM

LOWER FLOOR

100' - 0" (X' - X")

T

NEW FLOOR

SLAB

NEW CMU

WALL, ALIGN

WITH EXISTING

EXISTING

CONCRETE

FLOOR SLAB

EXISTING

FOUNDATION

3" RIGID

INSULATION

2" RIGID

INSULATION

NEW FND - SEE

STRUCTURAL

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

W A

L L

S E

C T

IO

N

S

-1

.0

A

J u n e

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.M

A A

/1

/2

/3

/2

1/2" = 1'-0"A 322

1 WALL SECTION

1/2" = 1'-0"A 322

2 WALL SECTION

1/2" = 1'-0"A 322

3 WALL SECTION

1 1/2" = 1'-0"A 322

1A WALL DETAIL 1 1/2" = 1'-0"A 322

3A WALL DETAIL

1 1/2" = 1'-0"A 322

3B WALL DETAIL

1 1/2" = 1'-0"A 322

1B WALL DETAIL

1/2" = 1'-0"A 322

4 WALL SECTION

1 1/2" = 1'-0"A 322

4A WALL DETAIL

1 1/2" = 1'-0"A 322

4B WALL DETAIL

NEW 3-

HOUR CMU

NEW BRICK

VENEER

3" RIGID INSULATION

BOARD. SEAL ALL JOINTS

WITH SPRAY FOAM

/8

/4

/8

NEW CMU WALL

TO ALIGN W/

EXISTING

CONTROL JOINT

AIR GAP

1 3/8"

2" EXPANSION

JOINT

A1

/8

/4

/8

7 5/8"

CMU

BRICK VENEER

3" RIGID INSULATION

BOARD. SEAL ALL JOINTS

WITH SPRAY FOAM

AIR GAP

/8

/4

/8

7 5/8"

NEW VENEER

BRICK

CONCRETE VAULT

WALLS

CMU WALL

3" INSULATION

CONTROL JOINT

1 3/4" AIR GAP

/8

/4

/8

VAULT TO BE

PARGE COATED

/8

/4

/8

7 5/8"

/8

CMU

UTILITY BRICK

VENEER

3" RIGID INSULATION

BOARD. SEAL ALL JOINTS

WITH SPRAY FOAM

AIR GAP

T

CMU

EXISTING

CMU/ BRICK

WALL

BRICK VENEER

/8

/4

/8

3" RIGID INSULATION

BOARD. SEAL ALL

JOINTS WITH SPRAY

FOAM

5/8" GYPSUM

BOARD ON 2 1/2"

METAL STUDS

SEAL JOINT

EXPANSION JOINT

AIR GAP

D

CMU

EXISTING

CMU/ BRICK

WALL UTILITY BRICK

VENEER

3' - 4"

/8

3 5/8" 1 1/4"

3 5/8"

/8

2' - 7 1/4"

/8

/4 "3

/8

A

LI

N

EXISTING PORTION OF

WALL-MOUNTED

HANDRAIL TO REMAIN

CUT EXISTING

HANDRAIL TO MEET

WALL

EXISTING BRICK

VENEER TO REMAIN

AIR GAP

D

3' - 4"

CMU

UTILITY BRICK

VENEER

/2

3 5/8"

1 1/4"

3 5/8"

/8

/4

/8

EXISTING

CMU/ BRICK

WALL

EXISTING BRICK

VENEER TO REMAIN

A

LI

AIR GAP

CONTINUOUS SEALANT

WITH 3/8"x3"

COMPRESSIBLE BACKER

ROD

FACE BRICK - REFER TO

ELEVATIONS

NOTE:

• SASH BLOCK UNITS REQUIRED FULL

HEIGHT, BOTH SIDES OF JOINT, USING

WHOLE AND HALF BLOCK SASH UNITS

FOR A RUNNING BOND COURSING

APPEARANCE - USING SASH UNITS AT

ALTERNATE COURSES IS NOT

ACCEPTABLE AND JOINTS CONSTRUCTED

THIS WAY WILL BE REMOVED AND

REPLACED AT CONTRACTOR'S EXPENSE

• TRUSS TYPE HORIZONTAL MASONRY

WALL JOINT REINFORCING AT INTERIOR

MASONRY WALLS ONLY - LADDER TYPE

HORIZONTAL MASONRY WALL JOINT

REINFORCING (AS SHOWN) AT EXTERIOR

WALLS

• REFER TO FLOOR PLAN FOR WALL

THICKNESS AND UNIT TYPE

HORIZONTAL WALL REINFORCING

AT 16" O.C. WITH PINTLE-EYE

VENEER ATTACHMENT - DO NOT

EXTEND REINFORCING THROUGH

CONTROL JOINT

3" INSULATION

SEALANT WITH BACKER ROD BOTH

SIDES OF BLOCK

MASONRY CONTROL INSERT WITH SASH

UNIT BOTH SIDES (REFER TO NOTE ABOVE)

/8

/4

/8

A T

B

LO

C K

A T

B

LO

C K

1 3/4" AIR GAP

FACE BRICK

S E E P

LA

N

CONTINUOUS SEALANT WITH

3/8"x3" COMPRESSIBLE

BACKER ROD

CMU

T

5.9

NEW DOUBLE EGRESS HM

FRAME (120 MIN)

NEW FIRE CAULK BOTH

SIDES

NEW 3-HOUR CMU WALL

NEW 2" EXPANSION

JOINT

NEW CMU INFILL AT OLD

OHD (INNER WYTHE)

NEW CMU INFILLI AT OLD

OHD (OUTER WYTHE)

A1

T

12.2

NEW DOUBLE EGRESS HM FRAME

(120 MIN)

NEW FIRE CAULK BOTH SIDES

NEW 3 HOUR CMU WALL

NEW 2" EXPANSION JOINT

EX. CMU

EX. BRICK

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

P L A

N D

E T

A

IL

S

-1

.0

A

J u n e

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.M

A A

/1

/2

/3

/2

1 1/2" = 1'-0"A 351

1 PLAN DETAIL

1 1/2" = 1'-0"A 351

2 PLAN DETAIL

1 1/2" = 1'-0"A 351

3 PLAN DETAIL

1 1/2" = 1'-0"A 351

4 PLAN DETAIL

1 1/2" = 1'-0"A 351

5 PLAN DETAIL

1 1/2" = 1'-0"A 351

6 PLAN DETAIL

1 1/2" = 1'-0"A 351

7 PLAN DETAIL

1 1/2" = 1'-0"A 351

8 CONTROL JOINT @ EXTERIOR WALL

1 1/2" = 1'-0"A 351

10 CONTROL JOINT DETAIL AT CMU

ISSUED FOR DATE

ADDENDUM 1 AUGUST 3

1 1/2" = 1'-0"A 351

11 DOUBLE EGRESS DOOR JAMB

1 1/2" = 1'-0"A 351

12 DOUBLE EGRESS DOOR JAMB

NEW 3-

HOUR CMU

NEW BRICK

VENEER

3" RIGID INSULATION

BOARD. SEAL ALL JOINTS

WITH SPRAY FOAM

/8

/4

/8

NEW CMU WALL

TO ALIGN W/

EXISTING

CONTROL JOINT

AIR GAP

1 3/8"

2" EXPANSION

JOINT

A1

/8

/4

/8

7 5/8"

CMU

BRICK VENEER

3" RIGID INSULATION

BOARD. SEAL ALL JOINTS

WITH SPRAY FOAM

AIR GAP

/8

/4

/8

7 5/8"

NEW VENEER

BRICK

CONCRETE VAULT

WALLS

CMU WALL

3" INSULATION

CONTROL JOINT

1 3/4" AIR GAP

/8

/4

/8

VAULT TO BE

PARGE COATED

/8

/4

/8

7 5/8"

/8

CMU

UTILITY BRICK

VENEER

3" RIGID INSULATION

BOARD. SEAL ALL JOINTS

WITH SPRAY FOAM

AIR GAP

T

CMU

EXISTING

CMU/ BRICK

WALL

BRICK VENEER

/8

/4

/8

3" RIGID INSULATION

BOARD. SEAL ALL

JOINTS WITH SPRAY

FOAM

5/8" GYPSUM

BOARD ON 2 1/2"

METAL STUDS

SEAL JOINT

EXPANSION JOINT

AIR GAP

D

CMU

EXISTING

CMU/ BRICK

WALL UTILITY BRICK

VENEER

3' - 4"

/8

3 5/8" 1 1/4"

3 5/8"

/8

2' - 7 1/4"

/8

/4 "3

/8

A

LI

EXISTING PORTION OF

WALL-MOUNTED

HANDRAIL TO REMAIN

CUT EXISTING

HANDRAIL TO MEET

WALL

EXISTING BRICK

VENEER TO REMAIN

AIR GAP

D

3' - 4"

CMU

UTILITY BRICK

VENEER

/2

3 5/8"

1 1/4"

3 5/8"

/8

/4

/8

EXISTING

CMU/ BRICK

WALL

EXISTING BRICK

VENEER TO REMAIN

A

LI

AIR GAP

CONTINUOUS SEALANT

WITH 3/8"x3"

COMPRESSIBLE BACKER

ROD

FACE BRICK - REFER TO

ELEVATIONS

NOTE:

• SASH BLOCK UNITS REQUIRED FULL

HEIGHT, BOTH SIDES OF JOINT, USING

WHOLE AND HALF BLOCK SASH UNITS

FOR A RUNNING BOND COURSING

APPEARANCE - USING SASH UNITS AT

ALTERNATE COURSES IS NOT

ACCEPTABLE AND JOINTS CONSTRUCTED

THIS WAY WILL BE REMOVED AND

REPLACED AT CONTRACTOR'S EXPENSE

• TRUSS TYPE HORIZONTAL MASONRY

WALL JOINT REINFORCING AT INTERIOR

MASONRY WALLS ONLY - LADDER TYPE

HORIZONTAL MASONRY WALL JOINT

REINFORCING (AS SHOWN) AT EXTERIOR

WALLS

• REFER TO FLOOR PLAN FOR WALL

THICKNESS AND UNIT TYPE

HORIZONTAL WALL REINFORCING

AT 16" O.C. WITH PINTLE-EYE

VENEER ATTACHMENT - DO NOT

EXTEND REINFORCING THROUGH

CONTROL JOINT

3" INSULATION

SEALANT WITH BACKER ROD BOTH

SIDES OF BLOCK

MASONRY CONTROL INSERT WITH SASH

UNIT BOTH SIDES (REFER TO NOTE ABOVE)

/8

/4

/8

A T

B

LO

C K

A T

B

LO

C K

1 3/4" AIR GAP

FACE BRICK

S E E P

LA

N

CONTINUOUS SEALANT WITH

3/8"x3" COMPRESSIBLE

BACKER ROD

CMU

T

5.9

NEW DOUBLE EGRESS HM

FRAME (120 MIN)

NEW FIRE CAULK BOTH

SIDES

NEW 3-HOUR CMU WALL

NEW 2" EXPANSION

JOINT

NEW CMU INFILL AT OLD

OHD (INNER WYTHE)

NEW CMU INFILLI AT OLD

OHD (OUTER WYTHE)

A1

T

12.2

NEW DOUBLE EGRESS HM FRAME

(120 MIN)

NEW FIRE CAULK BOTH SIDES

NEW 3 HOUR CMU WALL

NEW 2" EXPANSION JOINT

EX. CMU

EX. BRICK

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

P L A

N D

E T

A

IL

S

-1

.0

A

J u n e

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.M

A A

/1

/2

/3

/2

1 1/2" = 1'-0"A 351

1 PLAN DETAIL

1 1/2" = 1'-0"A 351

2 PLAN DETAIL

1 1/2" = 1'-0"A 351

3 PLAN DETAIL

1 1/2" = 1'-0"A 351

4 PLAN DETAIL

1 1/2" = 1'-0"A 351

5 PLAN DETAIL

1 1/2" = 1'-0"A 351

6 PLAN DETAIL

1 1/2" = 1'-0"A 351

7 PLAN DETAIL

1 1/2" = 1'-0"A 351

8 CONTROL JOINT @ EXTERIOR WALL

1 1/2" = 1'-0"A 351

10 CONTROL JOINT DETAIL AT CMU

ISSUED FOR DATE

ADDENDUM 1 08-03-2023

1 1/2" = 1'-0"A 351

11 DOUBLE EGRESS DOOR JAMB

1 1/2" = 1'-0"A 351

12 DOUBLE EGRESS DOOR JAMB

UP

DN

FINISH PLAN KEY

VCT CPT

WALL FINISH

FLOOR BASE

FLOOR FINISH

COUNTER FINISH

CABINET FINISH (BASE AND UPPER)

INDICATES EXTENT OF ATYPICAL FINISH

INDICATES FLOOR MATERIAL TRANSITION

NOTE - REFER TO MATERIAL SELECTION SCHEDULE

REMARKS FOR FLOOR TRANSITION TYPE

REFER TO MATERIAL SELECTION

SCHEDULE FOR FINISH INFORMATION

PL-#

PL-#

P-#

RB-#

CPT-#

P-#

INDICATES MULTIPLE MATERIAL TYPES ON A SURFACE.

REFER TO DETAIL OR ELEVATIONS.

INDICATES MATERIAL PATTERN. REFER TO DETAILS

MULTI

- P

GENERAL NOTES - INTERIORS

1. REFER TO ARCHITECTURAL FLOOR PLANS AND SPECIFICATION FOR ADDITIONAL

INFORMATION ON CONSTRUCTION MATERIALS.

2. REFER TO ARCHITECTURAL FLOOR PLANS FOR VISUAL DISPLAY BOARD LOCATIONS

AND QUANTITIES.

3. REFER TO ARCHITECTURAL FLOOR PLANS FOR LOCKER LOCATIONS, FINISHES AND

QUANTITIES.

4. REFER TO REFLECTED CEILING PLANS FOR CEILING FINISH AND HEIGHTS.

5. REFER TO ENLARGED STAIR PLANS AND SECTIONS FOR FINISH COLORS OF STRINGERS

AND GUARDRAILS.

6. REFER TO DOOR SCHEDULE FOR FINISH ON DOORS AND FRAMES.

7. REFER TO ENLARGED FINISH PLANS FOR TOILET ROOM FINISHES.

8. FINISH TAGS APPLY TO LIKE MATERIALS IN ENTIRE ROOM. I.E. CASEWORK TAG MAY

ONLY CALLOUT ONE RUN OF CASEWORK, BUT ALL CASEWORK IN ROOM RECEIVE THE

SAME FINISHES, UNLESS TAGGED DIFFERENTLY.

9. WALL MOUNTED DIFFUSERS, GRILLES, ACCESS PANELS, ELECTRICAL PANELS, ETC. ARE

TO BE PAINTED WITH AN OIL-BASED PAINT TO MATCH THE ADJACENT WALL FINISH.

10. CEILING ACCESS PANELS ARE TO BE PAINTED TO MATCH ADJACENT CEILING FINISH.

11. ALL EXPOSED COLUMNS TO BE PAINTED P-1.

12. ALL WALLS SHOULD BE PAINTED TO THE FLOOR IN ROOMS WHERE NO BASE IS

INDICATED

FLOORING DIRECTIONAL ARROW

CEMENT PARGING COAT ON CEILING AND EXPOSED

CONCRETE WALLS OF VAULT, PRIME AND PAINT

PRIME AND PAINT WALL SURFACE WHERE

INDICATED WITH DASHED LINES

A1

TRAINING

READINESS

ADMINISTRATION

SUPPLY

GENERAL

OFFICE

VESTIBULE

STORAGE

PLATOON

PLATOON

OFFICE

CORRIDOR

CONFERENCE

SUPPLY OFFICE

1 SARGENT

COMMANDER

CHAIR TABLE

STORAGE

WORKOUT

ROOM

NBC

TA 50 / OFFICE

PLATOON 1

PLATOON 2

PLATOON 3

COMM

CORRIDOR

TOILET

CLOSET

CLASSROOM

RECRUIT

SIPR

129MAIL

P-1

RB-1

SC-1

P-1

SC-1

SC-1

P-1

RB-1

CPTL-2

P-1

RB-1

CPTL-2

P-1

RB-2

LVT-2 P-1

RB-1

CPTL-2

P-1

RB-1

VCT-1

P-1

RB-2

LVT-2

SCULLERY

HOT FOOD

PREP

COLD FOOD

PREP

MESS OFFICE

BREAK ROOM

CLOSET

WOMENS

TOILET

P-1

RB-1

SC-1

P-1

RB-1

SC-1

P-1

RB-1

SC-1

P-1

RB-1

SC-1

P-1

RB-1

SC-1

P-1

RB-1

SC-1

P-1

RB-1

SC-1

P-1

RB-1

SC-1

P-1

RB-1

SF-1

P-1

RB-1

SC-1

P-1

RB-1

SC-1

P-1

RB-2

LVT-1

P-1

RB-1

SC-1

P-1

RB-1

CPTL-1

P-1

RB-1

SC-1

P-1

RB-1

ECPTL-1

P-1

RB-1

CPTL-2

P-1

RB-1

CPLT-3

VESTIBULE

REMOVE & REINSTALL

CARPET TILE AT NEW WALL

P-1

RB-2

LVT-1

P-1

RB-1

CPTL-1

P-1

RB-1

CPTL-1

P-1

RB-1

CPTL-2

P-1

RB-1

CPTL-2

P-1

RB-1

CPTL-2

P-1

RB-1

CPTL-2

P-1

RB-1

CPTL-2

P-1

RB-1

CPTL-2

P-1

RB-1

CPTL-2

P-1

RB-1

CPTL-2

P-1

RB-1

CPTL-2

P-1

RB-1

CPTL-2

MEN'S

RESTROOM

MENS TOILET

JAN

AV STORAGE

MEN'S

SHOWER

CLASSROOM

PLATOON 2

PLATOON 2

A 631

A 631

A 631

LAC

STORAGE

PES 200

UNIFORM

STORAGE

RECRUIT

VESTIBULE

E X

P T

PT EX EX PT

S C

V C

T

S C

C P T L

S C

C P T L

SSM-1

PL-1

SSM-1

PL-1

SSM-1

PL-1

A 631

SUPPLY OFFICE

FAMILY

LEARNING

LVT EX

C P T

LV

T

SC CPTL

SC ECPTL

SC ECPTL

WOMENS

TOILET

A 631

A 631

S C

C P T L

VESTIBULE

A 621

A 621

A 621

P-2

RBST-1

S C

R B S T

VCT EX

LV

T

S C

EX SF

EX SF

BOILER ROOM

SERVICE

OFFICE

SERVICE

PARTS / TOOLS

BUILDING

MAINTENANCE

PAINT SOFFIT & BULKHEAD WITH P - 1.

REFER TO A201

PAINT SOFFIT & BULKHEAD WITH P - 1.

REFER TO A201

PAINT SOFFIT & BULKHEAD WITH P - 1.

REFER TO A201

PAINT SOFFIT & BULKHEAD WITH P - 1.

REFER TO A201

P-1

RB-1

SC-1

A1

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F

IR

S T

F L

O O

R F

IN

IS

H P

L A

N

-1

.0

A

J u n e

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.M

A A

/1

/2

/3

/2

MIDLAND ARMORY

KEY PLAN

E

A A

C

DB

SCALE: NO SCALE

EXISTING

NEW

BCD

F G

H

I

1/8" = 1'-0"

UPPER AND LOWER FLOOR FINISH PLAN

D G K L M P

E F H J N R SCBA T

EXIST.5"

EXIST.8" ST EXIST.6" ST

EX

IS

T.

S T

EXIST.4" SANEXIST.5" SAN

EX

IS

T.

3"

S

AN

EXIST.6" ST

E X

IS

T .6

S T

E X

IS

T .4

S A N

E X

IS

T .4

S A N

E X

IS

T .4

S A N

E X

IS

T .6

S T

EXIST.10" ST EXIST.8" ST

E X

IS

T .6

S T

EXIST.6" ST

E X

IS

T .6

S T

EXIST.4" ST

EXIST.4" SAN

EXIST.4" SAN

E X

IS

T .4

S A N

EXIST.4" SAN

EXIS

T.4

" S

AN

A1

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig a n

-5

.3

.6

P H

O

E

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F O

U N

D A

T

IO

N P

L U

M B

IN

G

D E

M O

L

IT

IO

N

P L A

N

-1

.0

P D

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

KEYED NOTES - DEMOLITION

1 ABANDON SANITARY PIPING BELOW FLOOR.

2 DEMO BURIED SANITARY AS INDICATED. COORDINATE DEMOLITION

WITH NEW WORK THIS AREA.

3 DEMO DOMESTIC CW, HW, & HWR PIPING AS INDICATED. COORDINATE

WITH NEW WORK.

4 DEMO VENT PIPING AS INDICATED. COORDINATE WITH NEW WORK.

5 DEMO FLOOR DRAIN OR CLEAN OUT. CAP & ABANDON SANITARY

BELOW FLOOR.

6 DEMO WATER CLOSET, PREP EXIST UTILITIES FOR CONNECTION TO

NEW. COORDINATE WITH NEW WORK.

7 DEMO URINAL, PREP EXIST UTILITIES FOR CONNECTION TO NEW.

COORDINATE WITH NEW WORK.

8 DEMO LAV OR SINK, PREP EXIST UTILITIES FOR CONNECTION TO NEW.

COORDINATE WITH NEW WORK.

9 DEMO LAV OR SINK AND ALL ASSOCIATED UTILITIES BACK TO MAINS &

CAP.

10 DEMO EWC, PREP EXIST UTILITIES FOR CONNECTION TO NEW.

COORDINATE WITH NEW WORK.

11 DEMO DOWNSPOUT NOZZLE AND PORTION OF STORM OVERFLOW

PIPING. COORDINATE WITH NEW WORK.

12 EXIST. STORM PIPING TO BE REROUTED. DEMO AS INDICATED.

1/8" = 1'-0"

FOUNDATION PLUMBING DEMOLITION PLAN

MIDLAND ARMORY

KEY PLAN

SCALE: NO SCALE

EXISTING

NEW

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

ADDENDUM #1 08-02-2023

D G K L M P

E F H J N R SCBA T

3 3

MAIL

BREAK ROOM

RECRUIT

CLOSET

WMNS TOILET

VESTIBULE

MENS TOILET

CLASSROOM

CHAIR TABLE

STORAGE

WORKOUT ROOM

BOILER ROOM

BUILDING

MAINTENANCE

CLASSROOM

RECRUIT

CORRIDOR

FAMILY

LAC

E X

IS

T .6

S T

E X

IS

T .3

C

W E X

IS

T .2

H W

E X

IS

T .3

/4 H W

R

EXIST.6" ST (OF)

E X

IS

T .6

S T

E X

IS

T .2

V

A1

A1

A1

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig

-5

.3

.6

P H

O

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F

IR

S T

F L

O O

R P

L U

M B

IN

G

D E

M O

L

IT

IO

N

P L A

N

-1

.0

P D

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

KEYED NOTES - DEMOLITION

1 ABANDON SANITARY PIPING BELOW FLOOR.

2 DEMO BURIED SANITARY AS INDICATED. COORDINATE DEMOLITION

WITH NEW WORK THIS AREA.

3 DEMO DOMESTIC CW, HW, & HWR PIPING AS INDICATED. COORDINATE

WITH NEW WORK.

4 DEMO VENT PIPING AS INDICATED. COORDINATE WITH NEW WORK.

5 DEMO FLOOR DRAIN OR CLEAN OUT. CAP & ABANDON SANITARY

BELOW FLOOR.

6 DEMO WATER CLOSET, PREP EXIST UTILITIES FOR CONNECTION TO

NEW. COORDINATE WITH NEW WORK.

7 DEMO URINAL, PREP EXIST UTILITIES FOR CONNECTION TO NEW.

COORDINATE WITH NEW WORK.

8 DEMO LAV OR SINK, PREP EXIST UTILITIES FOR CONNECTION TO NEW.

COORDINATE WITH NEW WORK.

9 DEMO LAV OR SINK AND ALL ASSOCIATED UTILITIES BACK TO MAINS &

CAP.

10 DEMO EWC, PREP EXIST UTILITIES FOR CONNECTION TO NEW.

COORDINATE WITH NEW WORK.

11 DEMO DOWNSPOUT NOZZLE AND PORTION OF STORM OVERFLOW

PIPING. COORDINATE WITH NEW WORK.

12 EXIST. STORM PIPING TO BE REROUTED. DEMO AS INDICATED.

1/8" = 1'-0"

FIRST FLOOR PLUMBING DEMOLITION PLAN

MIDLAND ARMORY

KEY PLAN

SCALE: NO SCALE

EXISTING

NEW

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

D G K L M P

E F H J N R SCBA T

5 5

E X

IS

T .1

/2

H S

E X

IS

T .2

H S

E X

IS

T .2

H R

E X

IS

T .1

/2

H R

E X

IS

T .1

/2

H S

E X

IS

T .1

/2

H R

EXIST.2" HS

EXIST.2" HR

EXIST.1 1/4" HR

EXIST.1 1/4" HS

E X

IS

T .1

/4

H R

E X

IS

T .2

H S

EXIST.2" HS

EXIST.2" HS

EXIST.2" HR

EXIST.2" HR

EXIST.2" HS

EXIST.2" HR

EXIST.2" HR

EXIST.1 1/4" HS

EXIST.1 1/2" HR

EXIST.1 1/4" HS

EXIST.1 1/4" HR

EXIST.1 1/4" HS

EXIST.1 1/4" HR

EXIST.3/4" HR

EXIST.2" HS

EXIST.1 1/2" HR

EXIST.1 1/2" HS

E X

IS

T .1

/4

H R

E X

IS

T .2

H S

EXIST.1 1/2" HR

EXIST.1 1/2" HS

E X

IS

T .1

/2

H S

E X

IS

T .1

/2

H R

E X

IS

T .2

H S

E X

IS

T .1

H R

E X

IS

T .1

/2

H R

E X

IS

T .1

/2

H S

E X

IS

T

"x

S A

E X

IS

T

"x

S A

EXIST. 14"x10" SA

EXIST. 14"x10" SA

EXIST. 36"x36" RA

EXIST. 72"x18" RA

EXIST. 8"ø SA

EXIST. 10"ø RA

EXIST. 12"x10" EA

EXIST. 8"ø EA

EXIST. 72"x18" RA

EXIST. 8"ø SA

EXIST. 8"x10" SA

EXIST. 8"ø SA EXIST. 8"x10" SA

EXIST. 8"ø SA

EXIST. AHU

E X

IS

T

"x

O

A

EXIST. 30"x14" RA

A1

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig

-5

.3

.6

P H

O

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F

IR

S T

F L

O O

R M

E C

H A

N

IC

A L

D E

M O

L

IT

IO

N

P L A

N

-1

.0

M D

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

KEYED NOTES - DEMOLITION

1 DEMO AIR HANDLING UNIT & ASSOCIATED DUCTWORK, PIPING,

SUPPORTS, AND CONTROLS. DEMO HS & HR PIPING BACK TO MAINS

AND CAP. COORDINATE DEMO WITH NEW WORK.

2 DEMO EXHAUST FAN AND ASSOCIATED DUCTWORK AND CONTROLS.

3 DEMO FINNED TUBE AND ASSOCIATED PIPING AND CONTROLS. DEMO

HS & HR PIPING BACK TO MAINS AND CAP.

4 DEMO DUCTWORK AS SHOWN. COORDINATE DEMO WITH NEW WORK.

5 DEMO GRILLE OR DIFFUSER AND ASSOCIATED DUCTWORK AS SHOWN.

COORDINATE DEMO WITH NEW WORK.

6 REMOVE ROOFTOP UNIT IN ITS ENTIRETY INCLUDING ALL ASSOCIATED

PIPING, WIRING, CONTROLS, ETC. ROOF CURB TO REMAIN INTACT FOR

REUSE.

MIDLAND ARMORY

KEY PLAN

SCALE: NO SCALE

EXISTING

NEW

1/8" = 1'-0"

FIRST FLOOR MECHANICAL DEMOLITION PLAN THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

D G K L M P

E F H J N R SCBA TD G K L M PE F H J N R SCBA T

15.2

12.2

8.6

ROOF ACCESS

RTU-4

(E.T.R.)

RTU-1

(E.T.R.)

RTU-3

(E.T.R.)

EF-3

(E.T.R.)

EF-2

(E.T.R.)

EF-5

(E.T.R.)

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig

-5

.3

.6

P H

O

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

R O

O F

M E

C H

A N

IC

A

L D

E M

O L

IT

IO

N P

L A

N

-1

.0

M D

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

KEYED NOTES - DEMOLITION

1 DEMO AIR HANDLING UNIT & ASSOCIATED DUCTWORK, PIPING,

SUPPORTS, AND CONTROLS. DEMO HS & HR PIPING BACK TO MAINS

AND CAP. COORDINATE DEMO WITH NEW WORK.

2 DEMO EXHAUST FAN AND ASSOCIATED DUCTWORK AND CONTROLS.

3 DEMO FINNED TUBE AND ASSOCIATED PIPING AND CONTROLS. DEMO

HS & HR PIPING BACK TO MAINS AND CAP.

4 DEMO DUCTWORK AS SHOWN. COORDINATE DEMO WITH NEW WORK.

5 DEMO GRILLE OR DIFFUSER AND ASSOCIATED DUCTWORK AS SHOWN.

COORDINATE DEMO WITH NEW WORK.

6 REMOVE ROOFTOP UNIT IN ITS ENTIRETY INCLUDING ALL ASSOCIATED

PIPING, WIRING, CONTROLS, ETC. ROOF CURB TO REMAIN INTACT FOR

REUSE.

MIDLAND ARMORY

KEY PLAN

SCALE: NO SCALE

EXISTING

NEW

1/8" = 1'-0"

ROOF MECHANICAL PLAN

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

D G K L M P

E F H J N R SCBA T

EXIST.6" ST

EXIST.4" SAN

EXIST.6" ST

EXIST.5" SAN

EXIST.8" ST

EX

IS

T.

S T

EXIST.6" ST

E X

IS

T .3

V

EXIST.10" ST

EXIST.4" SAN

EXIST.4" SAN

EXIST.8" ST

E X

IS

T .6

S T

E X

IS

T .4

S A N

E X

IS

T .4

S A N

E X

IS

T .4

S A N

EXIST.4" SAN

EXIST.4" SAN

E X

IS

T .4

S A N

E X

IS

T .6

S T

EXIST.6" ST

E X

IS

T .6

S T

EXIST.4" ST

EXIST.4" SAN

EXIST.3" SAN

EXIST.4" SAN

3" SAN

9 8

S A N

6" ST

FROM ABOVE

3" SAN

5" SAN

E X

IS

T .6

S T

EXIST.5" SAN

3" SAN

3" SAN

3" SAN

A1

G R E A S E

A1

6" ST

6" ST. UP

(26" B.F.F.)

A1

CO

SH

V UP

SK

F.D.

SH

V UP

3" SAN

A1

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig

-5

.3

.6

P H

O

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F O

U N

D A

T

IO

N P

L U

M B

IN

G

P L A

N

-1

.0

P

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

KEYED NOTES - PLUMBING

1 CONNECT TO EXIST. SANITARY DRAIN.

2 6" ST, REFER TO CIVIL DRAWINGS FOR CONTINUATION.

3 CONNECT TO EXIST. ROOF OVERFLOW PIPING.

4 1 1/2" SAN UP TO LAV OR SINK.

5 3" ST & ST(OF) DN FROM ROOF DRAIN.

6 ST & ST(OF) PIPING DOWN, REFER TO P 000 FOR CONTINUATION OF

ST. PROVIDE CLEANOUT AT BASE OF ST STACK.

7 4" SAN UP TO CLEANOUT.

8 2" SAN UP TO MOP BASIN.

9 2" SAN UP TO SHOWER.

10 CONNECT TO EXIST. DOMESTIC WATER PIPING.

11 CONNECT FIXTURES TO EXIST. SAN. AND DOMESTIC WATER PIPING.

12 1 1/2" VENT UP.

13 1/2" HW & CW DOWN, 2" SAN UP, 1 1/2" WASTE UP.

14 ROUTE 1 1/2"V AND 1 1/2" PUMPED SAN AS INDICATED. REFER TO

SINK DRAIN PUMP DETAIL.

15 6" ST & ST(OF) DOWN FROM ROOF DRAIN.

16 CONNECT TO EXIST. ST. PIPING.

17 3" SAN UP TO FD.

18 PUMPED SAN ROUTED DOWN THROUGH BLOCK WALL. PROVIDE WALL

CLEANOUT AT BASE OF STACK. REFER TO FOUNDATION PLUMBING

PLAN FOR CONTINUATION.

19 3" SAN UP TO SLAB.

1/8" = 1'-0"

FOUNDATION PLUMBING PLAN

MIDLAND ARMORY

KEY PLAN

SCALE: NO SCALE

EXISTING

NEW

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

D G K L M P

E F H J N R SCBA T

S T O

F

S T

S T

E X

IS

T .3

C

W E X

IS

T .2

H W

E X

IS

T .3

/4 H W

R

EXIST.2 1/2" CW

EXIST.3/4" HW

EXIST.3/4" HWR

E X

IS

T .3

/4 H W

R E X

IS

T .2

H W

E X

IS

T .3

C

W

E X

IS

T .3

/4 H W

R E X

IS

T .2

H W

E X

IS

T .3

C

W

2" CW

1 1/4" HW

EXIST.6" ST (OF)

EWC-1

B.F.

LAV-1

B.F.

LAV-1

B.F.

WC-1

WC-1

WC-2

BF

SK-1

LAV-1

B.F.

3/4" CW

3/4" HW

1/2" HWR

5 6

3" ST

6" ST

6" ST (OF)

P 301

PES 200 UNIFORM

STORAGE

VAULT

SUPPLY OFFICE

CORRIDOR

VESTIBULE

VESTIBULE

READINESS

TRAINING

GENERAL OFFICE

ADMINISTRATION

SUPPLY

PLATOON

PLATOON

OFFICE

STORAGE

OFFICE

CONFERENCE

LEARNING

CMDR

1 SGT

OFFICE

TA 50 / OFFICE

PLATOON 1

PLATOON 2

PLATOON 3

COMM

NBC

SUPPLY ROOM

MAIL

130 SIPR

BREAK ROOM

RECRUIT

CLOSET

WMNS TOILET

VESTIBULE

MENS TOILET

MEN'S RESTROOM

MEN'S LOCKER

MEN'S SHOWER

JAN

AV STORAGE

CLASSROOM

CHAIR TABLE

STORAGE

WORKOUT ROOM

BOILER ROOM

WOMEN'S SHOWERS

BUILDING

MAINTENANCE

CLASSROOM

RECRUIT

CORRIDOR

FAMILY

LAC

CORRIDOR

CORRIDOR

3" FCO

P 301

1/2" HWR

6" ST (OF)

3" ST (OF)

6" ST

E X

IS

T .6

S T

(18" A.F.F.)

6" DS-1

S T O

F

S T O

F

(18" A.F.F.)

6" DS-1

CBV: 0.5 GPM

3" VTR

/2 S A N

6" ST (OF)

A1

A1

A1

A1

A1

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig

-5

.3

.6

P H

O

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F

IR

S T

F L

O O

R P

L U

M B

IN

G

P L A

N

-1

.0

P

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

KEYED NOTES - PLUMBING

1 CONNECT TO EXIST. SANITARY DRAIN.

2 6" ST, REFER TO CIVIL DRAWINGS FOR CONTINUATION.

3 CONNECT TO EXIST. ROOF OVERFLOW PIPING.

4 1 1/2" SAN UP TO LAV OR SINK.

5 3" ST & ST(OF) DN FROM ROOF DRAIN.

6 ST & ST(OF) PIPING DOWN, REFER TO P 000 FOR CONTINUATION OF

ST. PROVIDE CLEANOUT AT BASE OF ST STACK.

7 4" SAN UP TO CLEANOUT.

8 2" SAN UP TO MOP BASIN.

9 2" SAN UP TO SHOWER.

10 CONNECT TO EXIST. DOMESTIC WATER PIPING.

11 CONNECT FIXTURES TO EXIST. SAN. AND DOMESTIC WATER PIPING.

12 1 1/2" VENT UP.

13 1/2" HW & CW DOWN, 2" SAN UP, 1 1/2" WASTE UP.

14 ROUTE 1 1/2"V AND 1 1/2" PUMPED SAN AS INDICATED. REFER TO

SINK DRAIN PUMP DETAIL.

15 6" ST & ST(OF) DOWN FROM ROOF DRAIN.

16 CONNECT TO EXIST. ST. PIPING.

17 3" SAN UP TO FD.

18 PUMPED SAN ROUTED DOWN THROUGH BLOCK WALL. PROVIDE WALL

CLEANOUT AT BASE OF STACK. REFER TO FOUNDATION PLUMBING

PLAN FOR CONTINUATION.

19 3" SAN UP TO SLAB.

1/8" = 1'-0"

FIRST FLOOR PLUMBING PLAN

MIDLAND ARMORY

KEY PLAN

SCALE: NO SCALE

EXISTING

NEW

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

D G

E FCBA

MENS TOILET

MEN'S RESTROOM

MEN'S LOCKER

MEN'S SHOWER

JAN

AV STORAGE

SH-1

(TYP. OF 6)

WC-1

WC-1

UR-1

UR-1

UR-1

LAV-1

(TYP. OF 4)

UR-1

UR-1

WC-1

(TYP. OF 2)

MB-1

1/2" HWR

/4

H W

/4 C

W

1 1/4" HW

1 1/4" CW

3/4" HW

3/4" CW

1 1/4" CW

1 1/4" CW

1 1/4" HW

1 1/4" CW

LAV-1 (TYP. OF 3)

B.F.

1" CW

2" V

WC-1

B.F.

SH-1

(TYP. OF 6)

FD-1

FCO

2" V

V

2" V

1 1/2" V

CBV: 0.5 GPM

1 1/2" V

1 1/2" V

1 1/2" V

1 1/2" V

3/4" HW

3/4" CW

1 1/2" HW

2 1/2" CW

2" V

A1

1 1/2" V DN.

D

ECBA D ECBA

SH-1

SH-1

SH-1

SH-1

SH-1

SH-1

SH-1

1/2" HWR

1 1/4" HW

1 1/2" CW

/4

H W

/4

C

W

/4 C

W

LAV-1

B.F.

LAV-1

B.F.

WC-1 WC-1

V

/2 V

WOMEN'S SHOWERS

BUILDING

MAINTENANCE

E X

IS

T .6

S T

EXIST. VTR

2" V

E X

IS

T .2

V

A1

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig

-5

.3

.6

P H

O

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

E N

L A

R G

E D

P L

U M

B

IN

G P

L A

N S

-1

.0

P

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

1/4" = 1'-0"P 301

1 FIRST FLOOR PLUMBING PLAN - MENS SHOWERS

KEYED NOTES - ENLARGED PLUMBING

MIDLAND ARMORY

KEY PLAN

SCALE: NO SCALE

EXISTING

NEW

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

1 CONNECT TO EXIST.

2 MODIFY PIPING IN ORDER TO CONNECT TO EXIST. UTILITIES.

3 SUPPLY MANIFOLD WITH PEX PIPING TO INDIVIDUAL SHOWER

ASSEMBLIES.

4 3/4" HW & CW DOWN, 3" SAN DOWN, 1 1/2" VENT UP.

5 1" CW DOWN, 2" SAN UP, 1 1/2" VENT UP.

6 3/4" CW DOWN, 4" SAN DOWN, 2" VENT UP.

7 CONNECT TO EXIST 4" VTR.

8 NEW ST PIPING DOWN TIGHT TO WALL.

9 1/2" CW & HW DOWN, 2" SAN DOWN, 1 1/2" VENT UP.

1/4" = 1'-0"P 301

2 FIRST FLOOR PLUMBING PLAN - WOMENS SHOWERS

WASTE

VENT

FINISHED WALL

HWR PIPE WITH INSULATION

EXTENDING FROM LAST HW

CONNECTION (WHERE

APPLICABLE)

HW PIPE WITH INSULATION

ROUTED IN WALL OR CHASE

CW PIPE WITH

INSULATION ROUTED IN

WALL OR CHASE

SANITARY WYE FITTING

LAVATORY

½" CW & HW BRANCH PIPING

THRU WALL TO LAVATORY

ASSE 1070

MIXING VALVE

FIXTURE STOP

5"

MIN.

FINISHED FLOOR

OFFSET TRAP

ON B.F. UNITS

SEE ARCH DRAWINGS

FOR CASEWORK

DOMESTIC WATER

NATURAL GAS

COMPRESSED AIR

MEDICAL GASES

VACUUM

STEAM / CONDENSATE

BRANCH CONNECTION OFF TOP BRANCH CONNECTION OFF BOTTOM

APPLIES TO THE FOLLOWING SYSTEMS: APPLIES TO THE FOLLOWING SYSTEMS:

NOTE: BOTTOM AS INDICATED OR SIDE

CONNECTION IS ACCEPTABLE.

CONNECTION TO THE TOP OF THE MAINS

IS NOT ACCEPTABLE.

HEATING HOT WATER

CHILLED WATER

GEOTHERMAL

FINISHED WALL SURFACE

STANDARD WEIGHT STEEL

PIPE SLEEVE OF SIZE TO

PASS PIPE AND INSULATION

FINISHED ESCUTCHEON PLATE

FLUSH AGAINST WALL AND

OF SIZE TO COMPLETELY

COVER OPENING

CONCEALED PIPING

PIPE AND INSULATION TO BE

CENTERED IN SLEEVE - DO NOT

SUPPORT PIPE FROM SLEEVE

TERMINATE SLEEVE FLUSH WITH

FINISHED WALL SURFACES

SEAL AND CAULK ALL SLEEVES,

THRU FIRE WALL WITH FIRE

STOPPING SEALANTS

PIPING EXPOSED TO VIEW

SEAL BOTH SIDES WITH

ACOUSTICAL SEALANT

WALL

PIPE

INSULATION WHERE

SPECIFIED

1/2" MIN SPACE. PACK WITH

FIBROUS MATERIAL ALL AROUND GALVANIZED STEEL PIPE

SLEEVE FLUSH WITH WALL

IN

S U

LA

T E D

P

IP

E

NOTE

U N

IN

S U

LA

T E D

P

IP

E

1. WHERE PIPING IS EXPOSED TO VIEW PROVIDE WITH ESCUTCHEON.

2. FOR RATED WALLS REFER TO FIRE STOP SPECIFICATIONS.

FINISHED SLAB

NO-HUB COUPLING (TYP.)

FIRESTOP TO FLOOR RATING

ROUND STAINLESS

STEEL ACCESS

COVER PLATE (RE:

SPECIFICATIONS

FOR TYPE)

CLEANOUT PLUG (RE:

SPECIFICATIONS FOR

TYPE)

SANITARY DRAIN

(RE: PLAN FOR PIPE

SIZE & LOCATION)

FULL SIZE TEST TEE MAX

4" (RE: PLAN FOR PIPE

SIZE & LOCATION)

WALL (RE: ARCH. DWGS. FOR

SIZE AND TYPE)

CARPET CLIP

UNFINISHED OR

CARPETED FLOOR

FINISHED SLAB

NICKEL BRONZE TOP

SET SCREW

FINISHED FLOOR

FINISHED SLAB

CAST IRON CLEANOUT

BODY WITH PUSH-ON

GASKET

ADJUSTABLE TOP

HOUSING

GASKETED CONNECTION

PVC CLEANOUT PIPE

BRONZE CLEANOUT

PLUG WITH GASKETED

SEAL

Ti

HOT WATER

SUPPLY

HOT WATER

RETURN

BALANCING VALVECHECK VALVE

TEMPERATURE GAUGE

ISOLATION VALVE

FLOOR

VENT

WALL

FIXTURE OUTLET

CABINET

SINK

DRAIN PUMP BASED ON "LIBERTY" MODEL 406 SELF CONTAINED,

1-1/2" INLET, 1-1/2" DISCHARGE, 20 GPM AT 15 FT. W.G., 1/3 HP,

3450 RPM, 115V, 5.2A, 9 FT. POWER CORD ADN PLUG. INTEGRAL

CHECK VALVES ON INLET AND DISCHARGE.

SHUT OFF VALVE

UNION

P-TRAP

WASTE

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig

-5

.3

.6

P H

O

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

P L U

M B

IN

G

S C

H E

D U

L E

S A

N D

D E

T A

IL

S

-1

.0

P

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

SCALE: NONE

TYPICAL LAVATORY DETAIL

SCALE: NONE

BRANCH TAKE-OFF PIPING DETAIL

SCALE: NONE

PIPING SLEEVE DETAIL - INTERIOR WALL

SCALE: NONE

PENETRATION NOT RATED DETAIL

SCALE: NONE

WALL CLEANOUT DETAIL

SCALE: NONE

FLOOR CLEANOUT DETAIL

SCALE: NONE

BALANCING VALVE ASSEMBLY DETAIL

ISSUED FOR DATE

ADDENDUM #1 08-02-2023

SCALE: NONE

SINK DRAIN PUMP DETAIL

A1

D G K L M P

E F H J N R SCBA T

TRAINING

READINESS

ADMINISTRATION

SUPPLY

GENERAL

OFFICE

STORAGE

PLATOON

PLATOON

OFFICE

CONFERENCE

COMMANDER

LEARNING

1 SARGENT

CORRIDOR

TA 50 / OFFICE

SUPPLY OFFICE

PLATOON 1

PLATOON 2

PLATOON 3

COMM

SUPPLY ROOM

NBC

WORKOUT

ROOM

CHAIR TABLE

STORAGE

LAC

FAMILY

SIPR

MAIL

BREAK ROOM

RECRUIT

RECRUIT

WOMENS

TOILET

CORRIDOR

PES 200

UNIFORM

STORAGE

STORAGE

VESTIBULE

MENS TOILET

MEN'S LOCKER

MEN'S

RESTROOM

JAN

AV STORAGE

CLASSROOM

CLASSROOM

WOMEN'S

SHOWERS

WOMENS

TOILET

TOILET

SCULLERY

HOT FOOD

PREP

BOILER ROOM

SERVICE

OFFICE

COLD FOOD

PREP

MESS OFFICE

SERVICE

PARTS / TOOLS

SA-6

300 CFM

TYP. OF 4

RA-1

1200 CFM

RA-3

200 CFM

"ø

8"ø

SA-7

125 CFM

SA-7

125 CFM

SA-7

125 CFM

SA-7

125 CFM

SA-6

200 CFM

TYP. OF 2

SA-8

125 CFM

SA-7

150 CFM

8"ø

SA-7

125 CFM

SA-7

125 CFM

SA-6

200 CFM

TYP. OF 2

SA-6

300 CFM

TYP. OF 2

SS-210

RA-1

125 CFM

RA-1

150 CFM

RA-1

125 CFM

RA-1

125 CFM

SA-7

150 CFM

RA-1

150 CFM

RA-1

125 CFM

RA-1

125 CFM

RA-1

600 CFM

RA-1

125 CFM

SA-7

50 CFM

RA-1

400 CFM

EA-1

100 CFM

"ø

EA-1

400 CFM

SA-2

300 CFM

10"ø

SA-11 @45°

125 CFM

SA-10 @45°

500 CFM

TYP. OF 4

SA-6

275 CFM

SA-6

250 CFM

RA-1

275 CFM

14"ø

22"x20"

"x

10"ø10"ø

10"ø10"ø

RA-4

2000 CFM

14"ø

SA-10 @45°

500 CFM

TYP. OF 4

16"ø

8"x10"

1 2

1 2

10"ø

10"ø

"ø

6"x6"

SA-8

50 CFM

"x

16"x12"

14"ø

12"ø

SA-2

200 CFM

TYP. OF 2

"ø

8"ø

"ø

"ø

EA-1

500 CFM

TYP. OF 2

SA-3

100 CFM

EA-1

125 CFM

SA-2

125 CFM

SA-1

500 CFM

TYP. OF 2

SA-9

200 CFM

EA-2

75 CFM

RA-1

50 CFM

10"ø

RA-1

250 CFM

16"x12"

12"ø

"x

10"x10"

10"ø

"ø

"ø

"ø

"ø

10"ø

10"ø

8"ø

10"ø

"x

12"ø

14"x14"

8"ø

10"ø

10"ø

10"x8"

"x

"x

" 10"x6"

24"x24"

"x

12"x12"

EA-1

300 CFM

RA-5

1400 CFM

20"x12"

16"ø

SA-12 @45°

375 CFM

TYP. OF 4

"ø

"ø

"x

14"ø

32"x14"

14"x10"

24"x12"

18"x12"

14"x12"

6"x12"

RA-2

500 CFM

TYP. OF 4

"ø

SA-2

150 CFM

TYP. OF 4

RA-1

600 CFM

SA-7

270 CFM

SA-7

135 CFM

SA-7

80 CFM

SA-7

160 CFM

RA-1

270 CFM

RA-X

135 CFM

CH-2

18"x18"6"x6"

AHU (E.T.R.)

CH-1

16"x16"

10"ø

RHC-1

RHC-5

RHC-2

32"x24"

"ø

RHC-3

RHC-4

RHC-2E

24"x24"

20"x14"

24"x24"

24"x24"

RHC-6

A1

VAULT

A1

10"x8"

8"ø

10"ø

"ø

RA-1

400 CFM

A1

A1

12"x6"A1

A1

A1

A1

A1

A1

A1

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig

-5

.3

.6

P H

O

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F

IR

S T

F L

O O

R S

H E

E T

M E

T A

L P

L A

N

-1

.0

M

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

KEYED NOTES - MECHANICAL

1 SUPPLY AIR DOWN FROM ROOF, REFER TO SHEET M150 FOR

CONTINUATION.

2 RETURN AIR UP TO ROOF, REFER TO SHEET M150 FOR CONTINUATION.

3 EXHAUST AIR UP TO ROOF, REFER TO SHEET M150 FOR

CONTINUATION.

4 ROUTE DUCTWORK THROUGH JOIST WEBBING.

5 DROP DUCT DOWN INTO LOWER CEILING.

6 RAISE DUCT UP INTO HIGHER CEILING.

7 ROUTE DUCTWORK ABOVE CEILING AND UNDER JOISTS.

8 CONNECT TO EXIST. DUCTWORK.

1/8" = 1'-0"

FIRST FLOOR SHEET METAL PLAN

MIDLAND ARMORY

KEY PLAN

SCALE: NO SCALE

EXISTING

NEW

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

D G K L M P

E F H J N R SCBA T

ACCU-210

HRU-1

RTU-4

RTU-1

RTU-5

RTU-3

RTU-2E

RTU-2

RTU-4

(E.T.R.)

RTU-1

(E.T.R.)

RTU-3

(E.T.R.)

EF-3

(E.T.R.)

EF-2

(E.T.R.)

EF-5

(E.T.R.)

ROOF ACCESS

3" VTR

3" VTR

EXIST. VTR

A1

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig

-5

.3

.6

P H

O

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

R O

O F

M E

C H

A N

IC

A

L P

L A

N

-1

.0

M

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

KEYED NOTES - MECHANICAL

1 SUPPLY AIR DOWN FROM ROOF, REFER TO SHEET M150 FOR

CONTINUATION.

2 RETURN AIR UP TO ROOF, REFER TO SHEET M150 FOR CONTINUATION.

3 EXHAUST AIR UP TO ROOF, REFER TO SHEET M150 FOR

CONTINUATION.

4 ROUTE DUCTWORK THROUGH JOIST WEBBING.

5 DROP DUCT DOWN INTO LOWER CEILING.

6 RAISE DUCT UP INTO HIGHER CEILING.

7 ROUTE DUCTWORK ABOVE CEILING AND UNDER JOISTS.

8 CONNECT TO EXIST. DUCTWORK.

1/8" = 1'-0"

ROOF MECHANICAL PLAN

MIDLAND ARMORY

KEY PLAN

SCALE: NO SCALE

EXISTING

NEW

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

TS

TS

T S

TS

T S

T S

T S

T S

T S

T S

T S

TS

TS

D G K L PE F H J N R SCBA TD G K L M PE F H J N R SCBA T

U

15.2

12.2

8.6

5.9

FR-1

FR-3

FR-4

FR-5

FR-2

FR-6

E X

IS

T .1

/2

H S

E X

IS

T .1

/2

H R

1 1/4"

1 1/4"

1 1/2" HR

1 1/4" HS

1 1/4" HR

2 1/2" HS

2 1/2" HR

/4 H R

/4 H S P-1

21 GPM

P-2

14 GPM

P-3

8 GPM

P-6

8 GPM

P-4

PES 200 UNIFORM

STORAGE

VAULT

SUPPLY OFFICE

CORRIDOR

VESTIBULE

VESTIBULE

READINESS

TRAINING

229 GENERAL OFFICE

ADMINISTRATION

SUPPLY

PLATOON

PLATOON

OFFICE

STORAGE

OFFICE

CONFERENCE

LEARNING

CMDR

1 SGT

OFFICE

TA 50 / OFFICE

PLATOON 1

PLATOON 2

PLATOON 3

COMM

NBC

SUPPLY ROOM

MAIL

SIPR

BREAK ROOM

RECRUIT

CLOSET

WMNS TOILET

VESTIBULE

MENS TOILET

MEN'S RESTROOM

MEN'S LOCKER

MEN'S SHOWER

JAN

AV STORAGE

CLASSROOM

CHAIR TABLE

STORAGE

WORKOUT ROOM

BOILER ROOM

WOMEN'S SHOWERS

BUILDING

MAINTENANCE

CLASSROOM

RECRUIT

CORRIDOR

FAMILY

LAC

CORRIDOR

SS-210

3/4" HS

3/4" HR

1 1/4" HR

1" HR

/2 H S

/2 H R

CORRIDOR

CH-1

CH-2

P-5

8 GPM

1 1/4" HR

H S

1" HS

3/4" HR

1" HS

3/4" HS

3/4" HR

/4

H R

/4

H S

P-7

58 GPM

RTU-1

RTU-2

RTU-2E

RTU-3

RTU-4

HRU-1

RTU-5

RHC-1

21 GPM

RHC-5

8 GPM

RHC-2

RHC-3

8 GPM

RHC-4

8 GPM

EXIST.2" HR

EXIST.2" HS

RHC-2E

P-2E

11 GPM

1 1/2" HR

1 1/2" HS

H S

H R

/2 H S

1 1/4" HS

/2 H R

RHC-6

8 GPM

A1

A1

A1

A1

A1

A1

3/4" HR

A1

3/4" HS

3/4" HR

3/4" HS

3/4" HS

3/4" HR

A1

3/4" HS

A1

3/4" HS A1

1 1/4" HS

1 1/2" HS

1 1/4" HS

1 1/4" HR

A1

A1

A1EXIST.2" HR

EXIST.2" HR

EXIST.2" HS

EXIST.2" HR

EXIST.2" HS

A1

EXIST.1 1/4" HS

EXIST.1 1/4" HR

A1

E X

IS

T .2

H S

E X

IS

T .1

H R

EXIST.1 1/4" HR

EXIST.1 1/2" HS

E X

IS

T .1

/4

H R

E X

IS

T .2

H S

EXIST.1 1/2" HS

EXIST.1 1/2" HS

EXIST.1 1/2" HR

A1

A1

A1

EXIST.1 1/2" HS

EXIST.1 1/2" HR

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig

-5

.3

.6

P H

O

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F

IR

S T

F L

O O

R H

V A

C P

IP

IN

G P

L A

N

-1

.0

M

J U

N E

M

ID

L A

N D

A R

M O

R Y

A D

D

IT

IO

N

A N

D R

E N

O V

A T

IO

N

A

IR

P

O R

T R

O A

D

M

ID

L A

N D

M

I

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A N

D V

E T

E R

A N

'S A

F F

A

IR

S

/2

.C

A K

/1

/2

KEYED NOTES - HVAC PIPING

1 UNUSED

2 CONNECT TO EXIST. 1 1/2" HEATING WATER SUPPLY AND RETURN

PIPING.

3 CONNECT TO EXIST. 3" HEATING WATER SUPPLY AND RETURN PIPING.

4 REFRIGERANT PIPING UP THROUGH ROOF TO CONDENSING UNIT ON

ROOF.

5 LOCATE ALL NEW TEMPERATURE CONTROL PANEL(S) ON BACK WALL OF

STORAGE ROOM

1/8" = 1'-0"

FIRST FLOOR HVAC PIPING PLAN

MIDLAND ARMORY

KEY PLAN

SCALE: NO SCALE

EXISTING

NEW

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

ISSUED FOR DATE

OUTSIDE

AIR

SUPPLY RETURN

FILTER

COIL

CONTROLS AND

COMPRESSOR

ACCESS

5_

3_

4INSIDE BASE

RAIL

OUTSIDE BASE

RAIL

1_

501/2

ECONOMIZER

LIFTING LUG

(4 CORNERS)

3_

3_

SUPPLY

R E T U R N

5_

3_

C O

IL

F

IL

T E

R S

3_

EXHAUST

AIR

3_

7_

8 3

36 SUPPLY

R E T U R N

4 5

C O

IL

F

IL

T E

R S

7 3

EXHAUST

AIR

38781712

FILTER

COIL

LIFTING

LUG(4

CORNERS)

3_

4INSIDE BASE

RAIL

OUTSIDE BASE

RAIL

OUTSIDE

AIR

SUPPLY RETURN

CONTROLS AND

COMPRESSOR

ACCESS

1_

7_

3_

ECON

INSIDEBASE

RAILS

BLOWER

ACCESS

COIL

ACCESS

SUPPLY

BLOWER

SUPPLY COIL FILTER

FILTER

ACCESS

EXHAUST

AIR

OUTSIDE

AIR

AIR

FLOW

RETURN

40 5

82 1

O U T S

ID

E

A

IR

H O O D

SUPPLY

RETURN

C O

IL35

7 1

8 1

22388814

OUTSIDE

AIR

INSIDEBASE

RAILS

BLOWER

ACCESS

COMPRESSOR

ACCESS

COIL

ACCESS

FILTER

ACCESS

SUPPLY RETURN

BLOWER

SUPPLY COIL

FILTER

AIR

FLOW

ECON

EXHAUST

AIR

3_

5_

1_

SUPPLY

RETURN

C O

IL

O U T S

ID

E

A

IR

H O O D

1414 2412 3014 1312

SEE

DETAIL"B"

SEE

DETAIL"C"

SEE

DETAIL"A"

EXHAUST

AIR

SUPPLY

EXHAUST

AIR

O U T S

ID

E

A

IR

H O O D

RETURN

C O

IL

1234 2478 27 13

BLOWER

ACCESS HEATWHEEL

ACCESS

BLOWER

SUPPLY

COIL

COIL

ACCESS

FILTER ECON

HEATWHEEL

ACCESS

FILTER

ACCESS

OUTSIDE

AIR

AIR

FLOW

RETURNSUPPLY

HEATWHEEL

HEATWHEEL

FILTER

OUTSIDE

AIR

SUPPLY RETURN

FILTER

COIL

CONTROLS AND

COMPRESSOR

ACCESS

5_

3_

4INSIDE BASE

RAIL

OUTSIDE BASE

RAIL

1_

501/2

ECONOMIZER

LIFTING LUG

(4 CORNERS)

3_

3_

SUPPLY

R E T U R N

5_

3_

C O

IL

F

IL

T E

R S

3_

EXHAUST

AIR

3_

7_

OUTSIDE

AIR

SUPPLY RETURN

FILTER

COIL

CONTROLS AND

COMPRESSOR

ACCESS

5_

3_

4INSIDE BASE

RAIL

OUTSIDE BASE

RAIL

1_

501/2

ECONOMIZER

LIFTING LUG

(4 CORNERS)

3_

3_

SUPPLY

R E T U R N

5_

3_

C O

IL

F

IL

T E

R S

3_

EXHAUST

AIR

3_

7_

AREA SERVED: CLASSROOM

TYPE: PACKAGED OUTDOOR ROOFTOP UNIT, 1,400 CFM, HOT WATER HEATING, DX COOLING, DOWNWARD DISCHARGE

MANUFACTURER: BASED ON AAON "RN" SERIES

OUTSIDE AIR: 420 CFM OA

WEIGHT: 911 LB

LOCATION: ROOFTOP

UNIT MOUNTING: 14" ROOF CURB

UNIT DISCHARGE ACOUSTICS (Hz/db): 63/85, 125/83, 250/86, 500/82, 1000/75, 2000/72, 4000/70, 8000/64

ROOFTOP AIR HANDLING UNIT (RTU-4)

PLAN - TOP VIEW

ELEVATION - SIDE VIEW

FILTER SECTION: 2" PLEATED MERV-13 FILTERS

DX COOLING SECTION: 50.8 TMBH, 37.8 SMBH, 79°F EDB, 66°F EWB, 55°F LDB, 54°F LWB, R-410A

REFRIGERANT.

HEATING SECTION: (REFER TO DUCT-MOUNTED HEATING COIL SCHEDULE)

SUPPLY FAN: 1 FAN @ 2 HP, 1.01 BHP Ea., 1,400 CFM @ 1.25" ESP, 2.31" TSP, 1,821 RPM, 208/3/60, PREMIUM EFFICIENCY FOR USE WITH VFD, VFD PROVIDED BY TEMERPATURE CONTROLS CONTRACTOR.

RETURN/EXHAUST SECTION: 1 FAN @ 1 HP, 0.25 BHP, 1,400 CFM @ 0.25" ESP, 0.42" TSP, 1,330 RPM, 208-230/3/60, PREMIUM EFFICIENCY FOR USE WITH VFD, VFD PROVIDED BY TEMERPATURE CONTROLS

CONTRACTOR.

ELECTRICAL: SINGLE…