drawing - WATERPROOFING_QAC Historic Courthouse RFQ_2026.07.01.pdf
PDF 3 MB Posted
- Attached to
- Historic Courthouse Renovation
- Solicitation number
- BPM057809
- Issued by
- Queen Anne's County, Maryland
About this file
This is a waterproofing drawing document for Queen Anne's County's Historic Courthouse Renovation project located at 100 Courthouse Square in Centreville, Maryland. The drawing serves as a technical specification and visual reference for the waterproofing scope of work as part of the overall General Contractor Request for Qualifications (RFQ) for the complete renovation of the 17,800-square-foot Historic Courthouse. The renovation project encompasses comprehensive building systems replacement including HVAC, electrical, plumbing, and sprinkler systems, along with architectural improvements and asbestos abatement. The waterproofing drawing provides detailed construction specifications necessary for contractors to understand the exterior envelope protection requirements and integrate waterproofing measures throughout the renovation scope.
The waterproofing drawing is a technical component of the broader Historic Courthouse Renovation RFQ and contains construction details and specifications that General Contractor candidates must review and incorporate into their qualifications submissions. This drawing addresses the critical protective measures required to safeguard the historic structure during and after renovation, particularly given the building's age and previous weather-related deterioration history. The specifications ensure that all waterproofing systems meet current building codes and preservation standards appropriate for the historic courthouse structure while supporting the integration of new building systems and interior finishes planned throughout the renovation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Torchio Architects, Inc.
COPYRIGHT C
Project Number:
Date:
Revisions:
Drawn By:
Sheet:
0 C
O
UR
TH
O
US
E S
Q
UA
RE
CE
NT
RE
VI
LL
E, M
AR
YL
AN
D
I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, License Number 14756, Expiration Date 10/23/2026 James I. Magnuson
BECS PROJECT NUMBER:
Building Envelope Consultants and Scientists, LLC.
BECS
Maryland Office 875 Hollins Street, #201 Baltimore, MD 21213 443-873-6203 www.becsmd.com
20230564
AKMH / JM
Design By:
NOVEMBER 01, 2025
A2112
Q
UE
EN
A
NN
E'S
C O
UN
TY
100% CONSTRUCTION
DOCUMENTS
JM
HI
ST
O
RIC
C O
UR
TH
O
US
E R
EN
O
VA
TIO
N
BE0.1
W
AT
ER
PR
O O
FIN
G
G
EN
ER
AL
N O
TE
S
WATERPROOFING GENERAL NOTES
1. WATERPROOFING WORK INDICATED CONSISTS OF A BASE SCOPE OF WORK, AND
ALTERNATE WORK - REFER TO THE DRAWINGS FOR DESCRIPTIONS. ALTERNATE WORK IS
SUBTRACTIVE FROM THE BASE SCOPE, AND IN LIEU OF BASE SCOPE.
2. COMPLETE WATERPROOFING IN SEQUENCE AFTER COMPLETION OF SELECTIVE
DEMOLITION AND WALL INFILLS AND REPAIRS INDICATED IN THE ARCHITECTURAL
DRAWINGS, AND AFTER INSTALLATION OF ALL EQUIPMENT, SERVICES, PIPING, AND
SIMILAR WORK PENETRATING THROUGH AREAS SCHEDULED TO RECEIVE
WATERPROOFING.
3. LIMIT EXCAVATION EXTENTS FOR WATERPROOFING TO THE EXTENT POSSIBLE TO ACCESS
THE WORK AREAS. AVOID DISTURBANCE OF ADJACENT EXISTING-TO-REMAIN SITE
FEATURES WHEREVER POSSIBLE.
4. AFTER EXCAVATION, INJECT RESIN WATERPROOFING INTO ALL EXPOSED CRACKS AND
CONSTRUCTION COLD JOINTS IN EXISTING CONCRETE SHELTER ROOF AND WALLS WITHIN
THE WATERPROOFING WORK AREA PER WATERPROOFING MANUFACTURER
RECOMMENDATIONS.
5. PREPARE EXISTING CONCRETE AND MASONRY SUBSTRATES PER RECOMMENDATION OF
WATERPROOFING MANUFACTURER AS NECESSARY FOR WATERPROOFING INSTALLATION.
AT AREAS OF ADHERED WATERPROOFING, FILL VOIDS AND REMOVE RIDGES TO ACHIEVE A
SMOOTH UNIFORM SUBSTRATE, AND REMOVE ALL BOND-INHIBITING SUBSTANCES.
6. ALL WATERPROOFING THAT PROTRUDES ABOVE FINISHED GRADE SHALL BE FULLY
CONCEALED AND PROTECTED WITH COUNTERFLASHING EXTENDING DOWN BELOW
FINISHED GRADE AS INDICATED IN DETAILS.
7. AFTER COMPLETION OF WATERPROOFING, BACKFILL AREAS EXCAVATED FOR
WATERPROOFING, APPLY TOPSOIL, RE-GRADE, AND RE-SOD / RESTORE EXISTING
LANDSCAPING AS INDICATED IN THE CIVIL AND ARCHITECTURAL DRAWINGS.
8. REFER TO THE CIVIL DRAWINGS FOR ADDITIONAL SITEWORK ADJACENT TO THE
WATERPROOFING AND ELSEWHERE ON THE SITE THAT IS NOT SHOWN IN THESE
WATERPROOFING DRAWINGS.
9. REFER TO THE CIVIL DRAWINGS FOR ADDITIONAL INFORMATION ON THE PERIMETER
DRAIN SYSTEM INDICATED IN THESE WATERPROOFING DRAWINGS, AND FOR PIPING AND
CONNECTION OF THE PERIMETER DRAIN SYSTEM TO THE EXISTING CATCHBASIN.
10. REFER TO THE CIVIL DRAWINGS FOR ADDITIONAL INFORMATION ON EXCAVATION,
BACKFILLING, TOPSOIL, ROUGH AND FINISHED GRADING, AND SOD / LANDSCAPING
REQUIREMENTS FOR AREAS EXCAVATED FOR WATERPROOFING.
11. REFER TO THE ARCHITECTURAL, STRUCTURAL, AND M/E/P DRAWINGS FOR ADDITIONAL
WORK TO THE EXISTING BUILDING, EQUIPMENT CORRAL, AND SITE THAT IS NOT SHOWN
ON THESE WATERPROOFING DRAWINGS.
EXISTING-TO-REMAIN CONSTRUCTION
DRAWING SYMBOLS
STONE OR MARBLE
EARTH
RIGID INSULATION
BATT INSULATION
EXPANSION JOINT MATERIAL
ROUGH WOOD BLOCKING DISCONTINUOUS
PLYWOOD or ORIENTED STRAND BOARD
FINISHED WOOD
ROUGH WOOD CONTINUOUS
STEEL
GRAVEL or CRUSHED STONE
CONCRETE
CONCRETE BLOCK
BRICK
MATERIAL LEGEND
ABBREVIATIONS
NEW CONSTRUCTION
DEMOLITION
NORTH ARROW
ROOM OR AREA NAME SYMBOL
REVISION CALLOUT
CONSTRUCTION KEYNOTE
DEMOLITION KEYNOTE
LEVEL CALLOUTT/O XXXX
XX.XX'
COLUMN GRIDLINE AND BUBBLE
ELEVATION CALLOUT
SECTION CALLOUT
ENLARGED DETAIL CALLOUT
DRAWING TITLE
XXXX
XXXX
WINDOW TAGX
X DOOR TAG
ENGINEERENG.
IN.
LC
OPPOSITE / OPPOSITE HAND
OVERHEAD
OUTSIDE DIAMETER
ON CENTER
NOT TO SCALE
NUMBER
NOT IN CONTRACT
MOUNTING
METAL THRESHOLD
MASONRY OPENING
MISCELLANEOUS
MINIMUM
METAL
MEMBRANE
MECHANICAL
MATERIAL
MAXIMUM
MASONRY
LOW POINT
LAMINATE
OPP.
OH.
O.D.
O.C.
N.T.S.
NO.
N.I.C.
MTG.
M.T.
M.O.
MISC.
MIN.
MET. or MTL.
MEMB.
MECH.
MAT'L
MAX.
MAS.
L.P.
LAM.
JOINT
JANITOR CLOSET
INVERT
INSULATION
INCH
INSIDE DIAMETER
HIGH POINT
HORIZONTAL
HOLLOW METAL
HARDWARE
HOLLOW CORE
HOSE BIB
HEIGHT
GYPSUM
GYPSUM WALL BOARD
GENERAL CONTRACTOR
GALVANIZED
GAUGE
FOOTING
FEET or FOOT
FLOOR
FIXTURE
FINISH
FLOOR DRAIN
EXTERIOR
EXPANSION
EXISTING
EXHAUST
EQUIPMENT
EQUAL
ELEVATOR
ELECTRIC(AL)
ELEVATION
EXPANSION JOINT
EACH
DRAWING(S)
DOWNSPOUT
JT.
JAN.
INV.
INSUL.
I.D.
H.P.
HORIZ.
HM.
HDWE.
H.C.
H.B.
H. or HT.
GYP.
G.W.B.
G.C.
GALV.
GA.
FTG.
FT.
FLR.
FIXT.
FIN.
F.D.
EXTR.
EXP.
EXIST.
EXH.
EQUIP.
EQ.
ELEV.
ELEC.
EL.
E.J.
E.I.F.S.
EA.
DWG(S)
D.S.
DOWN
DIMENSION
DIAMETER
DETAIL
DOUBLE
CONTINUOUS
CONSTRUCTION
CONSTRUCTION JOINT
CONCRETE
COLUMN
CLEAN OUT
CONCRETE MASONRY UNIT
CLEAR
CEILING
CENTERLINE
CONTROL JOINT
CAST IRON
COURSES
BUILT UP
BASEMENT
BOTH SIDES
BRICK
BEARING
BOTTOM
BLOCKING
BLOCK
BUILDING
BOARD
AT
ARCHITECTURAL or ARCHITECT
APPROXIMATELY
ANGLE
AND
ALUMINUM
ALTERNATE
ABOVE FINISHED FLOOR
AREA DRAIN
ACOUSTICAL
ANCHOR BOLT
DN.
DIM.
DIA. or Ø
DET.
DBL.
CONT.
CONSTR.
CONST. JT.
CONC.
COL.
C.O.
CMU
CLR.
CLG.
CL or C.J.
C.I.
C.
B.U.
BSMT.
B.S.
BRK.
BRG.
BOT.
BLKG.
BLK.
BLDG.
BD.
ARCH.
APPROX.
ALUM.
ALT.
A.F.F.
A.D.
ACOUS.
A.B.
SCHEDULE
SOLID CORE
SANITARY
SCH.
S.C.
SAN.
ROUGH OPENING
REQUIRED
ROOF DRAIN
RISER
PAINTED
PREFABRICATE
PAIR
PANEL
PLYWOOD
PLATE
R.O.
REQ'D.
REINF.
R.D.
R.
PTD.
PREFAB.
PR.
PNL.
PLYWD.
PL.
REINFORCE(MENT) OR REINFORCING
BACKER ROD AND SEALANTBR&S
MANUFACTURE(R)MFR.
FIRE RETARDANT TREATED WOODFRT.
EXTERIOR INSULATION & FINISH SYSTEM
YARD
WELDED WIRE MESH
WELDED WIRE FABRIC
WATERPROOF
WOOD
WITHOUT
WITH
WIDTH
VERIFY IN FIELD
VERTICAL
UNLESS NOTED OTHERWISE
TYPICAL
TOP OF SLAB
TOP OF STEEL
TOP OF
TREAD
THICK
TONGUE & GROOVE
TEMPORARY
SUSPENDED or SUSPENSION STRUCTURE or STRUCTURAL
STORAGE
STEEL
STANDARD
STAINLESS STEEL
SQUARE
SPECIFICATIONS
SHEET METAL
SIMILAR
SHEET
SECTION
SEALANT
YD.
W.W.M.
W.W.F.
W.P.
WD.
W/O W/ W.
V.I.F.
VERT.
U.N.O.
TYP.
T.O.SL.
T.O.S.
T.O.
TR. or T.
THK.
T&G
TEMP.
SUSP.
STRUCT.
STOR.
STL.
STD.
S.STEEL
SQ.
SPECS.
S.M.
SIM.
SHT.
SECT.
SEAL.
WEATHER RESISTIVE BORDERWRB.
CLG-X CEILING TYPE TAG
ROOF TYPE TAGR-X
X WALL TYPE TAG
XXXX
XX
XXXX
XX
XXXX
XX
XXXX
XX
A
NOT FOR BID
DIN
G
OR C
ONSTRUCTIO
N
TY
P.
LI
NE
O F R
OO
F C
AN
T
SL
OP
E
EX. SLOPE EX. SLOPE
SHELTER ROOF BELOW
SLOPE
WATERPROOFING PLANA
BE1.1
Torchio Architects, Inc.
COPYRIGHT C
Project Number:
Date:
Revisions:
Drawn By:
Sheet:
0 C
O
UR
TH
O
US
E S
Q
UA
RE
CE
NT
RE
VI
LL
E, M
AR
YL
AN
D
I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, License Number 14756, Expiration Date 10/23/2026 James I. Magnuson
BECS PROJECT NUMBER:
Building Envelope Consultants and Scientists, LLC.
BECS
Maryland Office 875 Hollins Street, #201 Baltimore, MD 21213 443-873-6203 www.becsmd.com
20230564
AKMH / JM
Design By:
NOVEMBER 01, 2025
A2112
Q
UE
EN
A
NN
E'S
C O
UN
TY
100% CONSTRUCTION
DOCUMENTS
JM
HI
ST
O
RIC
C O
UR
TH
O
US
E R
EN
O
VA
TIO
N
SCALE: 1/8"=1'-0"
PLAN NORTH
BE1.1
W
AT
ER
PR
O O
FIN
G
P
LA
N
- B
AS
E S
CO
PE
EX. CURB (TYP.)
EX. BRICK WALK ABOVE (TYP.)
NORTH LIBERTY STREET
LA
W
YE
RS
R
OW
BR
OA
DW
AY
(FOUNDATION WALLS BELOW
COURTHOUSE BASEMENT LEVEL - SEE
ARCH. & STRUCT. DWGS.)
D
BE2.1
C
BE2.1
TYP.
KEY NOTES (BASE SCOPE - BE1.1):
1. EXCAVATE AND APPLY WATERPROOFING TYPE WP-1 TO EXISTING CONCRETE SHELTER ROOF
- TYPICAL. REFER TO DETAILS.
2. APPLY WATERPROOFING TYPE WP-2 TO VERTICAL FACE OF EXISTING WALL - TYPICAL. REFER
TO DETAILS.
3. EXISTING BRICK SITE WALL AROUND EQUIPMENT CORRAL TO REMAIN.
4. EXCAVATE AND EXPOSE ENTIRE EXISTING SHELTER ROOF AND EXTEND APPROXIMATELY 4
FEET DOWN ALONG FACE OF FOUNDATION WALL. AFTER INSTALLATION OF
WATERPROOFING, BACKFILL, RE-GRADE AND RE-SOD ABOVE EXISTING ROOF AREA - SEE
CIVIL DWGS.
5. APPLY WATERPROOFING TYPE WP-2 TO TOP AND SIDES NEW BELOW GRADE UTILITY
TUNNEL - SEE ARCH DWGS FOR TUNNEL. REFER TO TYPICAL WATERPROOFING DETAILS.
6. APPLY WATERPROOFING TYPE WP-2 TO BELOW-GRADE OUTSIDE FACES OF NEW VERTICAL
CONC. UTILITY CHASE - SEE ARCH. DWGS.
7. EXTEND WP-1 MEMBRANE BENEATH EXISTING BRICK WALL OF UTILITY ENCLOSURE TO
REMAIN. TEMPORARILY SHORE, REMOVE, SALVAGE & REINSTALL BOTTOM PORTION OF
BRICK WALL FOR WATERPROOFING INSTALLATION. SEE DETAIL INDICATED.
8. EXTEND WATERPROOFING TYPE WP-2 UP OUTSIDE EXISTING STAIR ENCLOSURE WALL AND
WATERPROOF TO GUARD RAIL POSTS - SEE ARCH. DWGS FOR GUARD RAIL AND CIVIL DWGS
FOR NEW BRICK ROWLOCK. REFER TO WATERPROOFING DETAIL INDICATED.
9. INJECT SPECIFIED RESIN WATERPROOFING PER MFR. RECOMMENDATIONS INTO ALL CRACKS
AND COLD JOINTS IN EXISTING CONCRETE SUBSTRATE BEFORE INSTALLATION OF
WATERPROOFING.
10. DEMOLISH EXISTING CONC. CURB DOWN TO THE TOP OF THE HIGH ROOF OVER STAIRWAY
VESTIBULE. CHIP, GRIND, & PATCH EXISTING CONC. TO CREATE UNIFORMITY SMOOTH
SUBSTRATE.
11. APPLY WATERPROOFING TYPE WP-1 ON SLOPED REPAIR MORTAR TO TOP OF EXISTING
SHELTER ROOF / STAIRWAY VESTIBULE HIGH ROOF.
12. PERIMETER DRAIN AT 24” BELOW EDGE OF SHELTER ROOF - TYPICAL ALL SIDES. SEE CIVIL
DWGS FOR DETAIL. REFER TO WATERPROOFING DETAIL INDICATED.
13. EXISTING CATCH BASIN - SEE CIVIL DWGS.
14. CONNECT PERIMETER DRAIN TO EXISTING CATCH BASIN - SEE CIVIL DWGS.
15. EXTEND PERIMETER DRAIN UNDER EQUIPMENT CORRAL WALL - SEE CIVIL DWGS.
16. FLASH WATERPROOFING MEMBRANE TO EXISTING STL. TUBE POSTS PER TYPICAL DETAILS.
17. APPLY WATERPROOFING TYPE WP-2 TO BELOW-GRADE FACE OF NEW OR EXISTING
FOUNDATION WALLS WHEREVER INDICATED WITH HEAVY DASHED LINE, TYPICAL. EXTEND
WATERPROOFING ON ALL SURFACES EXPOSED TO EARTH DOWN TO BOTTOM OF FOOTING /
UNDERPINNING FOR EACH WALL (EXTENT OF WATERPROOFING ON FOOTINGS IS NOT
DEPICTED FOR CLARITY). REFER TO TYPICAL FOUNDATION WALL WATERPROOFING DETAIL.
REFER TO ARCH. AND STRUCT. DWGS FOR WALL AND FOOTING / UNDERPINNING DEPTHS
AND DETAILS.
18. EXISTING UNDERGROUND UTILITIES IN AREA OF WORK - SEE CIVIL DWGS.
19. EXISTING METAL FIRE ESCAPE STAIR UP. SHORE AND SUPPORT IN PLACE - SEE CIVIL DWGS.
20. APPLY WATERPROOFING SYSTEM TYPE WP-2 TO BELOW-GRADE PORTION OF EXISTING
COURTHOUSE WALL AND TIE TO SPECIFIED WATERPROOFING SYSTEM ON SHELTER ROOF.
REFER TO WATERPROOFING DETAILS.
21. WATERPROOF JOINT BETWEEN NEW CONC. UTILITY TUNNEL AND FACE OF EXISTING CONC.
FOUNDATION WALL . SEE DWG BE1.3 FOR ADDITIONAL INFORMATION.
BE1.3
A
D
BE2.1 SIM.
D
BE2.1
C
BE1.3
BE2.1
G
SIM.
17 17 17
NOT FOR BID
DIN
G
OR C
EXCAVATE, BACKFILL, GRADE AND
SOD
HEMMED 16 OZ COPPER COUNTERFLASHING . EXTEND 4 INCHES
BELOW GRADE.
WATERPROOFING TYPE WP-2 ON EXISTING BRICK FOUNDATION
WALL. PREPARE SUBSTRATE PER MFR. RECEOMMENDATIONS
UNDISTURBED
SUBGRADE
EXISTING SHELTER ROOF
EXISTING
CONCRETE WALL
WATERPROOFING TYPE WP-1 ON EXISTING CONC.
SHELTER ROOF. PREPARE SUBSTRATE PER MFR.
RECEOMMENDATIONS
EXTEND COUNTERFLASHING INTO SAWCUT REGLET IN EXSTG. BRICK
BED JOINT. SECURE WITH LEAD WEDGES. POINT W/ MORTAR
TERMINATION BAR, RECOMMENDED FASTENERS & SEALANT CAP
BEAD
2'0"
TYP.
4' -0
TY
P.
TY
P.
LI
NE
O F R
OO
F C
AN
T
EX. SLOPE EX. SLOPE
SHELTER ROOF BELOW
2' -0
TY
P.
2' -0
TY
P.
2'-0"
TYP.
2'-0"
TYP.
2' -0
TY
P.
WATERPROOFING PLAN - ALTERNATE NO. 1A
BE1.2
Torchio Architects, Inc.
COPYRIGHT C
Project Number:
Date:
Revisions:
Drawn By:
Sheet:
0 C
O
UR
TH
O
US
E S
Q
UA
RE
CE
NT
RE
VI
LL
E, M
AR
YL
AN
D
I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, License Number 14756, Expiration Date 10/23/2026 James I. Magnuson
BECS PROJECT NUMBER:
Building Envelope Consultants and Scientists, LLC.
BECS
Maryland Office 875 Hollins Street, #201 Baltimore, MD 21213 443-873-6203 www.becsmd.com
20230564
AKMH / JM
Design By:
NOVEMBER 01, 2025
A2112
Q
UE
EN
A
NN
E'S
C O
UN
TY
100% CONSTRUCTION
DOCUMENTS
JM
HI
ST
O
RIC
C O
UR
TH
O
US
E R
EN
O
VA
TIO
N
SCALE: 1/8"=1'-0"
PLAN NORTH
BE1.2
W
AT
ER
PR
O O
FIN
G
P
LA
N
- A
LT
ER
NA
TE
N O
. 1
EX. CURB (TYP.)
EX. BRICK WALK ABOVE (TYP.)
NORTH LIBERTY STREET
NO
RT
H
LIB
ER
TY
ST
RE
ET
BR
OA
DW
AY
FINISHED GRADE
6" 1'
-6
VARIES - SEE PLAN
WATERPROOFING AT SHELTER ROOF AND WALL INTERSECTION ALTERNATE NO. 1B
BE1.2 SCALE: 1 1/2"=1'-0"
BASEMENT LEVEL COURTHOUSE
WATERPROOFING - INCLUDED IN
BASE SCOPE OF WORK - SEE A/BE1.1
B
BE1.2
TYP.
4"
EX. CATCH BASIN - SEE CIVIL DRAWINGS
EXCAVATE 2'-0" BEYOND WATERPROOFING
KEY NOTES (ALTERNATE NO. 1 - BE1.2):
1. APPLY WATERPROOFING TYPE WP-1 TO PORTION OF EXISTING SHELTER ROOF AND
TYPE WP-2 TOP EXISTING FOUNDATION WALL - SEE B/BE1.2. EXCAVATE AS
NECESSARY, BACKFILL, & RE-GRADE.
2. DEMOLISH EXISTING CONC. CURB DOWN TO THE TOP OF THE HIGH ROOF OVER
STAIRWAY VESTIBULE. CHIP, GRIND, & PATCH EXISTING CONC. TO CREATE
UNIFORMITY SMOOTH SUBSTRATE. EXCAVATE AS NECESSARY, BACKFILL, &
RE-GRADE.
3. APPLY WATERPROOFING TYPE WP-1 ON LIMITED AREA OF SHELTER ROOF AFTER
DEMOLITION OF CONC. CURB - SEE A/BE1.2. ATTACH EDGES OF MEMBRANE TO
SUBSTRATE WITH TERMINATION BAR AND MFR. RECOMMENDED SEALANT.
EXCAVATE AS NECESSARY, BACKFILL, & RE-GRADE.
5. APPLY WATERPROOFING TYPE WP-1 TO TOP ONLY OF NEW BELOW GRADE UTILITY
TUNNEL - SEE A/BE1.2. FASTEN EDGES WITH TERMINATION BAR AND MFR
RECOMMENDED SEALANT CAP BEAD. SEE ARCH AND STRUCT DWGS FOR TUNNEL.
EXCAVATE AS NECESSARY, BACKFILL, & RE-GRADE.
6. APPLY WATERPROOFING TYPE WP-2 TO UNDERGROUND PORTION OF NEW
VERTICAL CONC. UTILITY CHASE - SEE B/BE1.2. TERMINATE EDGES OF MEMBRANE
WITH TERMINATION BAR AND MANUFACTURER RECOMMENDED SEALANT CAP
BEAD 4 INCHES BELOW FINISHED GRADE. EXCAVATE AS NECESSARY, BACKFILL, &
RE-GRADE.
7. EXTEND WATERPROOFING TYPE WP-2 UP THIS PORTION OF OUTSIDE EXISTING
STAIR ENCLOSURE WALL AND FLASH INTO MORTAR JOINT IN NEW BRICK COPING -
SEE ARCH DWGS FOR BRICK COPING. REFER TO WATERPROOFING DETAIL
INDICATED. EXCAVATE AS NECESSARY, BACKFILL, & RE-GRADE.
8. WATERPROOF JOINT BETWEEN NEW UTILITY TUNNEL AND FACE OF EXISTING
BELOW-GRADE CONC. STAIR WALL PER DETAIL J/BE2.1. EXCAVATE AS NECESSARY,
BACKFILL, & RE-GRADE.
9. EXTEND WP-1 MEMBRANE BENEATH EXISTING BRICK WALL OF UTILITY ENCLOSURE
TO REMAIN. TEMPORARILY SHORE, REMOVE, SALVAGE & REINSTALL BOTTOM
PORTION OF BRICK WALL FOR WATERPROOFING INSTALLATION. SEE DETAIL
INDICATED. EXCAVATE AS NECESSARY, BACKFILL, & RE-GRADE.
10. APPLY WATERPROOFING TYPE WP-1 TO LIMITED AREA OF SHELTER ROOF BENEATH
EXISTING EQUIPMENT CORRAL AS INDICATED. TERMINATE EDGES OF MEMBRANE
WITH TERMINATION BAR AND MANUFACTURER RECOMMENDED SEALANT CAP
BEAD. EXCAVATE AS NECESSARY, BACKFILL, & RE-GRADE.
11. INJECT SPECIFIED RESIN WATERPROOFING PER MFR. RECOMMENDATIONS INTO ALL
CRACKS AND COLD JOINTS IN EXISTING CONCRETE SUBSTRATE BEFORE
INSTALLATION OF WATERPROOFING.
12. FLASH WATERPROOFING MEMBRANE TO EXISTING STL. TUBE POSTS PER TYPICAL
DETAILS.
13. EXISTING METAL FIRE ESCAPE STAIR UP. SHORE AND SUPPORT IN PLACE - SEE CIVIL
DWGS.
14. APPROXIMATE LIMIT OF EXCAVATION AREA FOR WATERPROOFING INSTALLATION
INDICATED AS A DASHED LINE.
2 3
J
BE2.1
C
BE1.3
SIM.
10 11
BE2.1
G
1 12" MIN.
NOT FOR BID
DIN
G
OR C
Torchio Architects, Inc.
COPYRIGHT C
Project Number:
Date:
Revisions:
Drawn By:
Sheet:
0 C
O
UR
TH
O
US
E S
Q
UA
RE
CE
NT
RE
VI
LL
E, M
AR
YL
AN
D
I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, License Number 14756, Expiration Date 10/23/2026 James I. Magnuson
BECS PROJECT NUMBER:
Building Envelope Consultants and Scientists, LLC.
BECS
Maryland Office 875 Hollins Street, #201 Baltimore, MD 21213 443-873-6203 www.becsmd.com
20230564
AKMH / JM
Design By:
NOVEMBER 01, 2025
A2112
Q
UE
EN
A
NN
E'S
C O
UN
TY
100% CONSTRUCTION
DOCUMENTS
JM
HI
ST
O
RIC
C O
UR
TH
O
US
E R
EN
O
VA
TIO
N
SL
OP
E
SLOPE
PLAN NORTH
MORTAR HI POINT
+ 2 12" ABOVE EXSTG. CONC.
MORTAR LOW POINT
+ 12" ABOVE EXSTG. CONC.
MORTAR LOW POINT
+ 12" ABOVE EXSTG. CONC.
EX
ST
G.
ST
AI
R
DO
W
N
TO
B
AS
EM
EN
T
LV
L.
WATERPROOFING DETAIL PLANA
BE1.3 SCALE: 1/4"=1'-0"
BE1.3
C
BE1.3
B
BE2.1
D
EXSTG. COURTHOUSE
REMOVE & DISPOSE OF EXSTG/ CONC. CURB DOWN TO
TOP OF EXSTG. UNDERGROUND SHELTER
EDGE OF EXSTG. UNDERGROUND SHELTER
TYPICAL PERIMETER DRAIN
NEW BRICK COPING & GUARD RAIL ATOP EXSTG. CONC.
RETAINING WALL - SEE ARCH. AND CIVIL DWG.
WATERPROOFING TYPE WP-1 ON
SLOPED REPAIR MORTAR TO TOP
OF EXSTG. SHELTER ROOF. MAX.
THICKNESS 2 1/2 INCHES / MIN. 12
INCH
LIMIT OF REPAIR MORTAR
CHANGE IN REPAIR MORTAR SLOPE
WATERPROOFING TYPE WP-1 ON
EXSTG. SHELTER ROOF
WATERPROOFING TYPE WP-1 ON TOP AND WP-2 ON SIDE
OF NEW CONC. UTILITY TUNNEL. SEE ARCH AND STRUCT
DWGS FOR UTILITY TUNNEL
EXSTG. BRICK WALL OF UTILITY ENCLOSURE TO REMAIN.
DO NOT UNDERMINE OR DAMAGE DURING EXCAVATION
AND WATERPROOFING WORK.
EXTEND WATERPROOFING TYPE
WP-1 BENEATH EXISTING BRICK
WALL - SEE DETAIL INDICATED.
NEW VERTICAL CONC. UTILITY CHASE - SEE ARCH. DWGS.
TURN-UP WATERPROOFING TYPE WP-2 ON OUTSIDE OF
UTILITY CHASE. TERMINATE 4 INCHES BELOW FNISHED
GRADE W/ TERMINATION BAR AND SEALANT CAP BEAD
SL
OP
E
WATERPROOFING TYPE WP-1 ON SLOPED REPAIR MORTAR
TO TOP OF EXSTG. SHELTER ROOF. MAX. THICKNESS 2 1/2
INCHES / MIN. 12 INCH
WATERPROOFING SECTIONB
BE1.3 SCALE: 1/4"=1'-0"
BE2.1
C SIM.
OMIT INSULATIONBE2.1
E
BE2.1
D
SLOPED REPAIR MORTAR. REMOVE EXSTG.
WATERPROOFING AND MECHANICALLY PROFILE
EXSTG. CONC. PER MFR. RECOMMENDATIONS.
WHERE MORTAR EXCEEDS 1 INCH THICKNESS,
EXTEND MORTAR WITH 38" PEA GRAVEL AT A RATE
OF 30 LBS GRAVEL TO 50 LBS DRY MORTAR MIX.
WATERPROOFING TYPE WP-1
EXCAVATE, STOCKPILE, BACKFILL & RE-GRADE -
SEE CIVIL DWGS.
BRICK COPING & GUARD
ATOP EXSTG. CONC.
RETAINING WALL - SEE
ARCH. DWGS.
W
AT
ER
PR
O O
FIN
G
D
ET
AI
L P
LA
N
AN
D
SE
CT
IO
NS
WATERPROOFING SECTIONC
BE1.3 SCALE: 1/4"=1'-0"
BE2.1
C SIM.
SEQUENTIALLY SHORE, REMOVE, SALVAGE, &
REINSTALL BOTTOM COURSES OF EXSTG. BRICK IN
3 FOOT SECTIONS FOR INSTALLATION OF
WATERPROOFING. PROVIDE INTERMITTENT GAPS
IN BOTTOM OF WALL TO ALLOW DRAINAGE AS
INDICATED IN THE DETAIL.
EXSTG. BRICK SITE WALL AROUND EQPT. CORRAL
TO REMAIN
EXSTG. CONC. SHELTER ROOF & WALL
WATERPROOFING WP-1 SEE A/BE1.2
CONC. UTILITY TUNNEL - SEE ARCH. & STRUCT.
DWGS.
BE2.1
FBE2.1
C SIM.
BE2.1
J
BE2.1
C SIM.
PERIMETER DRAIN
BE1.3
OPP
GUARD RAIL POST PENETRATION - SEE ARCH. DWGS. FOR
GUARD. FLASH PER E/BE2.1.
SIM.
NOT FOR BID
DIN
G
OR C
FINISHED GRADE
WATERPROOFING AT COURTHOUSE WALLD
BE2.1 SCALE:1 12" = 1'-0"
WATERPROOFING TYPE WP-1A
BE2.1 SCALE:1 12" = 1'-0"
WATERPROOFING AND BRICK CURB @ STAIRE
BE2.1 SCALE:1 12" = 1'-0"
WATERPROOFING TYPE WP-2B
BE2.1 SCALE:1 12" = 1'-0"
WATERPROOFING AND PERIMETER DRAINC
BE2.1 SCALE:1 12" = 1'-0"
EXISTING
CONCRETE
SHELTER WALL
EXISTING SHELTER ROOF
UNDISTURBED
SUBGRADE
LIMIT EXCAVATION TO
EXTENT NECESSARY FOR
WATERPROOFING WORK -
TYP.
FILTER FABRIC & #57
DRAINAGE FILL. PROVIDE
MIN. 3 INCH COVER AROUND
PIPE
TERMINATION BAR.
WATERPROOFING TYPE
WP-2 - SEE B/BE2.1
CHAMFER CONCRETE 2"x2"
LAP AND WELD WP-1 AND
WP-2 MEMBRANES PER MFR.
RECOMMENDATIONWATERPROOFING
TYPE WP-1 - SEE
A/BE2.1
1' -4
DE
PT
H
VA
RI
ES
BACKFILL, REGRADE AND RE-SOD - COORDINATE
EXCAVATION AND BACKFILL WITH CIVIL DRAWINGS
ADDITIONAL MEMBRANE -
REFER TO CIVIL DWGS.
EXISTING SHELTER ROOF
EXISTING BRICK
WALL
EXCAVATE, BACKFILL, GRADE AND
SOD
6" 1'
-6
4"
WATERPROOFING AT EXISTING EXTERIOR WALL WITHIN CORRALF
BE2.1 SCALE:1 12" = 1'-0"
DATUM: TOP OF
WALL/ UNDERSIDE
OF ROOF
BOTTOM OF
WATERPROOFING
FINISHED GRADE
3" 3"
EXISTING SOIL OVERBURDEN - EXCAVATE FOR WATERPROOFING THEN BACKFILL & RE-GRADE. REFER TO CIVIL
DWGS. FOR INFORMATION
R-10 MINIMUM RIGID FOAM INSULATION CONTINUOUS WITHOUT VOIDS OR GAPS. BUTT EDGES AND TIGHTLY
CUT AND COPE TO ADJACENT CONSTRUCTION AND PENETRATIONS.
DRAINAGE AND PROTECTION BOARD, CONTINUOUS.
DUAL PVC AND REACTIVE POLYMER FLEECE (RPF) SHEET WATERPROOFING. RPF LAYER SHOWN DASHED.
LOOSE-LAID.
INJECT SPECIFIED RESIN WATERPROOFING PER MFR. RECOMMENDATIONS INTO ALL CRACKS AND COLD JOINTS IN
EXSTG. CONCRETE SUBSTRATE BEFORE INSTALLATION OF WATERPROOFING
EXISTING CONCRETE SUBSTRATE. REMOVE SOIL,
ROCKS, LOOSE AND SPALLED CONCRETE, AND LOOSE
PORTIONS OF EXISTING ASPHALTIC WATERPROOFING
TO EXTENT RECOMMENDED BY WATERPROOFING
MEMBRANE MANUFACTURER. FULL REMOVAL OF
EXISTING WATERPROOFING IS NOT REQUIRED. MAKE
CONCRETE REPAIRS WHERE NECESSARY, AND
PREPARE SURFACE AS RECOMMENDED BY
WATERPROOFING MFR.
TYPICAL WATERPROOFING EDGE SEAM:
(1) CUT AND EXPOSE 3 INCHES OF RPF ALONG EDGE
OF "DOWNHILL" SHEET.
(2) REMOVE 3 INCHES OF RPF FROM EDGE OF
"UPHILL" SHEET.
(3) LAP UPHILL SHEET OVER DOWNHILL SHEET,
ACHIEVING OVERLAP DISTANCES INDICATED.
(4) HEAT WELD UPHILL SHEET TO DOWNHILL SHEET,
MINIMUM OF 12" WIDE WELD.
EXISTING SOIL OVERBURDEN - EXCAVATE FOR WATERPROOFING THEN BACKFILL & RE-GRADE. REFER
TO CIVIL DWGS. FOR INFORMATION
R-10 MINIMUM RIGID FOAM INSULATION CONTINUOUS WITHOUT VOIDS OR GAPS. BUTT EDGES AND
TIGHTLY CUT AND COPE TO ADJACENT CONSTRUCTION AND PENETRATIONS.
DRAINAGE AND PROTECTION BOARD, CONTINUOUS.
ADHERED REINFORCED THERMOPLASTIC FLASHING MEMBRANE.
INJECT SPECIFIED RESIN WATERPROOFING PER MFR. RECOMMENDATIONS INTO ALL CRACKS AND COLD
JOINTS IN EXSTG. CONCRETE SUBSTRATE BEFORE INSTALLATION OF WATERPROOFING
EXSTG. CONCRETE SUBSTRATE. CLEAN, INSPECT & REPAIR, AND PREPARE PER WATERPROOFING MFR.
RECOMMENDATIONS.
FLASHING AT TUBE POST WITH BASEPLATEG
BE2.1 SCALE:1 12" = 1'-0"
WATERPROOFING AT NEW FOUNDATION WALL & UNDERPINNINGH
BE2.1 SCALE:1 12" = 1'-0"
WATERPROOFING TYPE WP-2 (OMIT
INSULATION)
MANUF. APPLIED SEALANT ALONG
TOP EDGE.
TERMINATION BAR
MANUF. APPLIED SEALANT
CANT PER WATERPROOFING
MFR. RECOMMENDATIONS
INJECT SPECIFIED RESIN WATERPROOFING PER MFR. RECOMMENDATIONS INTO
ALL CRACKS AND COLD JOINTS IN EXSTG. CONCRETE SUBSTRATE BEFORE
INSTALLATION OF WATERPROOFING
EXISTING SHELTER ROOF
EXISTING
CONCRETE WALL
EXCAVATE, BACKFILL,
GRADE AND SOD
WATERPROOFING TYPE WP-1 SEE A/BE2.1
SEALANT CAP BEAD ALL AROUND
EXCAVATE, BACKFILL,
GRADE AND SOD
EXISTING SHELTER ROOF
4"
TERMINATION BAR
MANUF. APPLIED SEALANT CAP BEAD ALONG TOP EDGE
EXISTING METAL STAIR TUBE
HEMMED 16 OZ COPPER COUNTERFLASHING . EXTEND 4 INCHES
BELOW GRADE.
WATERPROOFING TYPE WP-2 ON EXISTING BRICK FOUNDATION
WALL. PREPARE SUBSTRATE PER MFR. RECEOMMENDATIONS
WATERPROOFING TYPE WP-1 ON EXISTING CONC.
SHELTER ROOF. PREPARE SUBSTRATE PER MFR.
RECEOMMENDATIONS
COUNTERFLASHING IN SAWCUT REGLET IN EXSTG. BRICK BED JOINT.
SECURE WITH LEAD WEDGES. POINT W/ MORTAR.
TERMINATION BAR, RECOMMENDED FASTENERS & SEALANT CAP
BEAD
EXCAVATE,
BACKFILL,
GRADE AND
SOD
EXISTING SHELTER ROOF
WP-1 MEMBRANE CONTINUOUS UNDER EXSTG. BRICK SITE WALL
LAMINATED STAINLESS STEEL FLASHING MEMBRANE AS SEPARATOR BETWEEN
BRICK AND WP-1 MEMBRANE
SEQUENTIALLY SHORE, REMOVE, SALVAGE, AND
REINSTALL BOTTOM COURSES OF EXSTG. BRICK IN
APPROX. 3 FOOT INTERMITTENT SECTIONS FOR
INSTALLATION OF WP-1 MEMBRANE. LAP AND HEAT
WELD ADJACENT WP-1 MEMBRANE SECTIONS
WATERTIGHT AS INDICATED IN DETAIL A/BE2.1.
WATERPROOFING TYPE WP-1 SEE A/BE1.2
EXSTG. BRICK SITE WALL AROUND EQPT. CORRAL TO
REMAIN
STOP DRAINAGE AND PROTECTION BOARD AND
INSULATION AT FACE OF WALL
WATERPROOFING TYPE WP-2 (OMIT INSULATION) SEE B/BE2.1
WATERPROOFING TYPE WP-1 SEE A/BE2.1
LAMINATED STAINLESS STEEL FLASHING EMBEDDED IN MORTAR BED
JOINT - FULL WIDTH OF WALL
TRANSITION TO HEMMED MILL STAINLESS STL. COUNTERFLASHING
AT EXTERIOR FACE OF WALL
PERFORATED PERIMETER
DRAIN - SEE CIVIL DWGS.
FIELD-FORMED PENETRATION FLASHING
BOOT - UNREINFORCED KEE DETAIL
MEMBRANE BY WATERPROOFING
MANUFACTURER. HEAT-WELD TO TOP OF
WP-1 MEMBRANE, AND ADHERE TO EXSTG.
STEEL TUBE.
" M
IN
CONCRETE UNDERPINNING
BY OTHERS. SEE STRUC.
DWG.
TERMINATION BAR
VA
RI
ES
SE
E
AR
CH
. A
ND
ST
RU
CT
. D
W
GS
VA
RI
ES
SE
E
AR
CH
. D W
GS
WATERPROOFING AT UTILITY TUNNEL / EXISTING STAIR WALLJ
BE2.1 SCALE:1 12" = 1'-0"
EXCAVATE, BACKFILL,
GRADE AND SOD
SEMI-CONDITIONED INTERIOR
SPACE BELOW EXISTING CONC.
STAIR
EXSTG. CONC. FOUNDATION
WALL & STAIR
STRIP-FLASH JOINT BETWEEN NEW &
EXSTG. CONC. W/ ADHERED
UNREINFORCED KEE DETAIL FLASHING
MEMBRANE. EXTEND 6 INCHES TO EITHER
SIDE OF JOINT.
NEW UTILITY OPNG. THRU EXSTG. WALL -
SEE MEP AND ARCH DWGS
TOP OF CONC. UTILITY TUNNEL - SEE
STRUCT. DWGS.
WATERPROOFING TYPE WP-1 SEE
A/BE2.1
LAP & HEAT-WELD WP-2 MEMBRANE
TO TOP OF WP-1 MEMBRANE PER MFR.
RECOMMENDATIONS
WATERPROOFING TYPE WP-2 SEE
B/BE2.1
TERMINATE TOP OF WP-2 SIMILAR TO DETAIL E/BE2.1 AT 4 INCHES BELOW FINISHED
GRADE
EXCAVATE & BACKFILL FOR
WATERPROOFING (SOILS NOT
SHOWN)
EXCAVATE & BACKFILL FOR
WATERPROOFING (SOILS NOT
SHOWN)
1 12"MIN.
NOTE: PROVIDE INTERMITTENT
OPENINGS THROUGH BOTTOM OF
BRICK WALL FOR WATER DRAINAGE - 8
INCHES WIDE x 2 BRICK COURSES HIGH, EVERY 24 INCHES.
FIELD-FORMED
PENETRATION FLASHING
BOOT - UNREINFORCED
KEE DETAIL MEMBRANE BY
WATERPROOFING
MANUFACTURER. ADHERE
TO POST AND TO TOP OF
LAMINATED S.STL.
FLASHING. SEAL
WATERTIGHT.
GUARD RAIL POSTS EMBEDDED IN EXSTG. WALL - SEE
ARCH. DWGS. FOR DESCRIPTION
SEALANT COVE BEAD
BRICK - SEE ARCH. DWGS.
Torchio Architects, Inc.
COPYRIGHT C
Project Number:
Date:
Revisions:
Drawn By:
Sheet:
0 C
O
UR
TH
O
US
E S
Q
UA
RE
CE
NT
RE
VI
LL
E, M
AR
YL
AN
D
I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, License Number 14756, Expiration Date 10/23/2026 James I. Magnuson
BECS PROJECT NUMBER:
Building Envelope Consultants and Scientists, LLC.
BECS
Maryland Office 875 Hollins Street, #201 Baltimore, MD 21213 443-873-6203 www.becsmd.com
20230564
AKMH / JM
Design By:
NOVEMBER 01, 2025
A2112
Q
UE
EN
A
NN
E'S
C O
UN
TY
100% CONSTRUCTION
DOCUMENTS
JM
HI
ST
O
RIC
C O
UR
TH
O
US
E R
EN
O
VA
TIO
N
BE2.1
W
AT
ER
PR
O O
FIN
G
D
ET
AI
LSNOT FOR BID
DIN
G
OR C
File details come from the government source that posted it. Updated .