drawing - WATERPROOFING_QAC Historic Courthouse RFQ_2026.07.01.pdf

PDF 3 MB Posted

Attached to
Historic Courthouse Renovation
Solicitation number
BPM057809
Issued by
Queen Anne's County, Maryland

About this file

This is a waterproofing drawing document for Queen Anne's County's Historic Courthouse Renovation project located at 100 Courthouse Square in Centreville, Maryland. The drawing serves as a technical specification and visual reference for the waterproofing scope of work as part of the overall General Contractor Request for Qualifications (RFQ) for the complete renovation of the 17,800-square-foot Historic Courthouse. The renovation project encompasses comprehensive building systems replacement including HVAC, electrical, plumbing, and sprinkler systems, along with architectural improvements and asbestos abatement. The waterproofing drawing provides detailed construction specifications necessary for contractors to understand the exterior envelope protection requirements and integrate waterproofing measures throughout the renovation scope.

The waterproofing drawing is a technical component of the broader Historic Courthouse Renovation RFQ and contains construction details and specifications that General Contractor candidates must review and incorporate into their qualifications submissions. This drawing addresses the critical protective measures required to safeguard the historic structure during and after renovation, particularly given the building's age and previous weather-related deterioration history. The specifications ensure that all waterproofing systems meet current building codes and preservation standards appropriate for the historic courthouse structure while supporting the integration of new building systems and interior finishes planned throughout the renovation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Torchio Architects, Inc.

COPYRIGHT C

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, License Number 14756, Expiration Date 10/23/2026 James I. Magnuson

BECS PROJECT NUMBER:

Building Envelope Consultants and Scientists, LLC.

BECS

Maryland Office 875 Hollins Street, #201 Baltimore, MD 21213 443-873-6203 www.becsmd.com

20230564

AKMH / JM

Design By:

NOVEMBER 01, 2025

A2112

Q

UE

EN

A

NN

E'S

C O

UN

TY

100% CONSTRUCTION

DOCUMENTS

JM

HI

ST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

BE0.1

W

AT

ER

PR

O O

FIN

G

G

EN

ER

AL

N O

TE

S

WATERPROOFING GENERAL NOTES

1. WATERPROOFING WORK INDICATED CONSISTS OF A BASE SCOPE OF WORK, AND

ALTERNATE WORK - REFER TO THE DRAWINGS FOR DESCRIPTIONS. ALTERNATE WORK IS

SUBTRACTIVE FROM THE BASE SCOPE, AND IN LIEU OF BASE SCOPE.

2. COMPLETE WATERPROOFING IN SEQUENCE AFTER COMPLETION OF SELECTIVE

DEMOLITION AND WALL INFILLS AND REPAIRS INDICATED IN THE ARCHITECTURAL

DRAWINGS, AND AFTER INSTALLATION OF ALL EQUIPMENT, SERVICES, PIPING, AND

SIMILAR WORK PENETRATING THROUGH AREAS SCHEDULED TO RECEIVE

WATERPROOFING.

3. LIMIT EXCAVATION EXTENTS FOR WATERPROOFING TO THE EXTENT POSSIBLE TO ACCESS

THE WORK AREAS. AVOID DISTURBANCE OF ADJACENT EXISTING-TO-REMAIN SITE

FEATURES WHEREVER POSSIBLE.

4. AFTER EXCAVATION, INJECT RESIN WATERPROOFING INTO ALL EXPOSED CRACKS AND

CONSTRUCTION COLD JOINTS IN EXISTING CONCRETE SHELTER ROOF AND WALLS WITHIN

THE WATERPROOFING WORK AREA PER WATERPROOFING MANUFACTURER

RECOMMENDATIONS.

5. PREPARE EXISTING CONCRETE AND MASONRY SUBSTRATES PER RECOMMENDATION OF

WATERPROOFING MANUFACTURER AS NECESSARY FOR WATERPROOFING INSTALLATION.

AT AREAS OF ADHERED WATERPROOFING, FILL VOIDS AND REMOVE RIDGES TO ACHIEVE A

SMOOTH UNIFORM SUBSTRATE, AND REMOVE ALL BOND-INHIBITING SUBSTANCES.

6. ALL WATERPROOFING THAT PROTRUDES ABOVE FINISHED GRADE SHALL BE FULLY

CONCEALED AND PROTECTED WITH COUNTERFLASHING EXTENDING DOWN BELOW

FINISHED GRADE AS INDICATED IN DETAILS.

7. AFTER COMPLETION OF WATERPROOFING, BACKFILL AREAS EXCAVATED FOR

WATERPROOFING, APPLY TOPSOIL, RE-GRADE, AND RE-SOD / RESTORE EXISTING

LANDSCAPING AS INDICATED IN THE CIVIL AND ARCHITECTURAL DRAWINGS.

8. REFER TO THE CIVIL DRAWINGS FOR ADDITIONAL SITEWORK ADJACENT TO THE

WATERPROOFING AND ELSEWHERE ON THE SITE THAT IS NOT SHOWN IN THESE

WATERPROOFING DRAWINGS.

9. REFER TO THE CIVIL DRAWINGS FOR ADDITIONAL INFORMATION ON THE PERIMETER

DRAIN SYSTEM INDICATED IN THESE WATERPROOFING DRAWINGS, AND FOR PIPING AND

CONNECTION OF THE PERIMETER DRAIN SYSTEM TO THE EXISTING CATCHBASIN.

10. REFER TO THE CIVIL DRAWINGS FOR ADDITIONAL INFORMATION ON EXCAVATION,

BACKFILLING, TOPSOIL, ROUGH AND FINISHED GRADING, AND SOD / LANDSCAPING

REQUIREMENTS FOR AREAS EXCAVATED FOR WATERPROOFING.

11. REFER TO THE ARCHITECTURAL, STRUCTURAL, AND M/E/P DRAWINGS FOR ADDITIONAL

WORK TO THE EXISTING BUILDING, EQUIPMENT CORRAL, AND SITE THAT IS NOT SHOWN

ON THESE WATERPROOFING DRAWINGS.

EXISTING-TO-REMAIN CONSTRUCTION

DRAWING SYMBOLS

STONE OR MARBLE

EARTH

RIGID INSULATION

BATT INSULATION

EXPANSION JOINT MATERIAL

ROUGH WOOD BLOCKING DISCONTINUOUS

PLYWOOD or ORIENTED STRAND BOARD

FINISHED WOOD

ROUGH WOOD CONTINUOUS

STEEL

GRAVEL or CRUSHED STONE

CONCRETE

CONCRETE BLOCK

BRICK

MATERIAL LEGEND

ABBREVIATIONS

NEW CONSTRUCTION

DEMOLITION

NORTH ARROW

ROOM OR AREA NAME SYMBOL

REVISION CALLOUT

CONSTRUCTION KEYNOTE

DEMOLITION KEYNOTE

LEVEL CALLOUTT/O XXXX

XX.XX'

COLUMN GRIDLINE AND BUBBLE

ELEVATION CALLOUT

SECTION CALLOUT

ENLARGED DETAIL CALLOUT

DRAWING TITLE

XXXX

XXXX

WINDOW TAGX

X DOOR TAG

ENGINEERENG.

IN.

LC

OPPOSITE / OPPOSITE HAND

OVERHEAD

OUTSIDE DIAMETER

ON CENTER

NOT TO SCALE

NUMBER

NOT IN CONTRACT

MOUNTING

METAL THRESHOLD

MASONRY OPENING

MISCELLANEOUS

MINIMUM

METAL

MEMBRANE

MECHANICAL

MATERIAL

MAXIMUM

MASONRY

LOW POINT

LAMINATE

OPP.

OH.

O.D.

O.C.

N.T.S.

NO.

N.I.C.

MTG.

M.T.

M.O.

MISC.

MIN.

MET. or MTL.

MEMB.

MECH.

MAT'L

MAX.

MAS.

L.P.

LAM.

JOINT

JANITOR CLOSET

INVERT

INSULATION

INCH

INSIDE DIAMETER

HIGH POINT

HORIZONTAL

HOLLOW METAL

HARDWARE

HOLLOW CORE

HOSE BIB

HEIGHT

GYPSUM

GYPSUM WALL BOARD

GENERAL CONTRACTOR

GALVANIZED

GAUGE

FOOTING

FEET or FOOT

FLOOR

FIXTURE

FINISH

FLOOR DRAIN

EXTERIOR

EXPANSION

EXISTING

EXHAUST

EQUIPMENT

EQUAL

ELEVATOR

ELECTRIC(AL)

ELEVATION

EXPANSION JOINT

EACH

DRAWING(S)

DOWNSPOUT

JT.

JAN.

INV.

INSUL.

I.D.

H.P.

HORIZ.

HM.

HDWE.

H.C.

H.B.

H. or HT.

GYP.

G.W.B.

G.C.

GALV.

GA.

FTG.

FT.

FLR.

FIXT.

FIN.

F.D.

EXTR.

EXP.

EXIST.

EXH.

EQUIP.

EQ.

ELEV.

ELEC.

EL.

E.J.

E.I.F.S.

EA.

DWG(S)

D.S.

DOWN

DIMENSION

DIAMETER

DETAIL

DOUBLE

CONTINUOUS

CONSTRUCTION

CONSTRUCTION JOINT

CONCRETE

COLUMN

CLEAN OUT

CONCRETE MASONRY UNIT

CLEAR

CEILING

CENTERLINE

CONTROL JOINT

CAST IRON

COURSES

BUILT UP

BASEMENT

BOTH SIDES

BRICK

BEARING

BOTTOM

BLOCKING

BLOCK

BUILDING

BOARD

AT

ARCHITECTURAL or ARCHITECT

APPROXIMATELY

ANGLE

AND

ALUMINUM

ALTERNATE

ABOVE FINISHED FLOOR

AREA DRAIN

ACOUSTICAL

ANCHOR BOLT

DN.

DIM.

DIA. or Ø

DET.

DBL.

CONT.

CONSTR.

CONST. JT.

CONC.

COL.

C.O.

CMU

CLR.

CLG.

CL or C.J.

C.I.

C.

B.U.

BSMT.

B.S.

BRK.

BRG.

BOT.

BLKG.

BLK.

BLDG.

BD.

ARCH.

APPROX.

ALUM.

ALT.

A.F.F.

A.D.

ACOUS.

A.B.

SCHEDULE

SOLID CORE

SANITARY

SCH.

S.C.

SAN.

ROUGH OPENING

REQUIRED

ROOF DRAIN

RISER

PAINTED

PREFABRICATE

PAIR

PANEL

PLYWOOD

PLATE

R.O.

REQ'D.

REINF.

R.D.

R.

PTD.

PREFAB.

PR.

PNL.

PLYWD.

PL.

REINFORCE(MENT) OR REINFORCING

BACKER ROD AND SEALANTBR&S

MANUFACTURE(R)MFR.

FIRE RETARDANT TREATED WOODFRT.

EXTERIOR INSULATION & FINISH SYSTEM

YARD

WELDED WIRE MESH

WELDED WIRE FABRIC

WATERPROOF

WOOD

WITHOUT

WITH

WIDTH

VERIFY IN FIELD

VERTICAL

UNLESS NOTED OTHERWISE

TYPICAL

TOP OF SLAB

TOP OF STEEL

TOP OF

TREAD

THICK

TONGUE & GROOVE

TEMPORARY

SUSPENDED or SUSPENSION STRUCTURE or STRUCTURAL

STORAGE

STEEL

STANDARD

STAINLESS STEEL

SQUARE

SPECIFICATIONS

SHEET METAL

SIMILAR

SHEET

SECTION

SEALANT

YD.

W.W.M.

W.W.F.

W.P.

WD.

W/O W/ W.

V.I.F.

VERT.

U.N.O.

TYP.

T.O.SL.

T.O.S.

T.O.

TR. or T.

THK.

T&G

TEMP.

SUSP.

STRUCT.

STOR.

STL.

STD.

S.STEEL

SQ.

SPECS.

S.M.

SIM.

SHT.

SECT.

SEAL.

WEATHER RESISTIVE BORDERWRB.

CLG-X CEILING TYPE TAG

ROOF TYPE TAGR-X

X WALL TYPE TAG

XXXX

XX

XXXX

XX

XXXX

XX

XXXX

XX

A

NOT FOR BID

DIN

G

OR C

ONSTRUCTIO

N

TY

P.

LI

NE

O F R

OO

F C

AN

T

SL

OP

E

EX. SLOPE EX. SLOPE

SHELTER ROOF BELOW

SLOPE

WATERPROOFING PLANA

BE1.1

Torchio Architects, Inc.

COPYRIGHT C

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, License Number 14756, Expiration Date 10/23/2026 James I. Magnuson

BECS PROJECT NUMBER:

Building Envelope Consultants and Scientists, LLC.

BECS

Maryland Office 875 Hollins Street, #201 Baltimore, MD 21213 443-873-6203 www.becsmd.com

20230564

AKMH / JM

Design By:

NOVEMBER 01, 2025

A2112

Q

UE

EN

A

NN

E'S

C O

UN

TY

100% CONSTRUCTION

DOCUMENTS

JM

HI

ST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

SCALE: 1/8"=1'-0"

PLAN NORTH

BE1.1

W

AT

ER

PR

O O

FIN

G

P

LA

N

- B

AS

E S

CO

PE

EX. CURB (TYP.)

EX. BRICK WALK ABOVE (TYP.)

NORTH LIBERTY STREET

LA

W

YE

RS

R

OW

BR

OA

DW

AY

(FOUNDATION WALLS BELOW

COURTHOUSE BASEMENT LEVEL - SEE

ARCH. & STRUCT. DWGS.)

D

BE2.1

C

BE2.1

TYP.

KEY NOTES (BASE SCOPE - BE1.1):

1. EXCAVATE AND APPLY WATERPROOFING TYPE WP-1 TO EXISTING CONCRETE SHELTER ROOF

- TYPICAL. REFER TO DETAILS.

2. APPLY WATERPROOFING TYPE WP-2 TO VERTICAL FACE OF EXISTING WALL - TYPICAL. REFER

TO DETAILS.

3. EXISTING BRICK SITE WALL AROUND EQUIPMENT CORRAL TO REMAIN.

4. EXCAVATE AND EXPOSE ENTIRE EXISTING SHELTER ROOF AND EXTEND APPROXIMATELY 4

FEET DOWN ALONG FACE OF FOUNDATION WALL. AFTER INSTALLATION OF

WATERPROOFING, BACKFILL, RE-GRADE AND RE-SOD ABOVE EXISTING ROOF AREA - SEE

CIVIL DWGS.

5. APPLY WATERPROOFING TYPE WP-2 TO TOP AND SIDES NEW BELOW GRADE UTILITY

TUNNEL - SEE ARCH DWGS FOR TUNNEL. REFER TO TYPICAL WATERPROOFING DETAILS.

6. APPLY WATERPROOFING TYPE WP-2 TO BELOW-GRADE OUTSIDE FACES OF NEW VERTICAL

CONC. UTILITY CHASE - SEE ARCH. DWGS.

7. EXTEND WP-1 MEMBRANE BENEATH EXISTING BRICK WALL OF UTILITY ENCLOSURE TO

REMAIN. TEMPORARILY SHORE, REMOVE, SALVAGE & REINSTALL BOTTOM PORTION OF

BRICK WALL FOR WATERPROOFING INSTALLATION. SEE DETAIL INDICATED.

8. EXTEND WATERPROOFING TYPE WP-2 UP OUTSIDE EXISTING STAIR ENCLOSURE WALL AND

WATERPROOF TO GUARD RAIL POSTS - SEE ARCH. DWGS FOR GUARD RAIL AND CIVIL DWGS

FOR NEW BRICK ROWLOCK. REFER TO WATERPROOFING DETAIL INDICATED.

9. INJECT SPECIFIED RESIN WATERPROOFING PER MFR. RECOMMENDATIONS INTO ALL CRACKS

AND COLD JOINTS IN EXISTING CONCRETE SUBSTRATE BEFORE INSTALLATION OF

WATERPROOFING.

10. DEMOLISH EXISTING CONC. CURB DOWN TO THE TOP OF THE HIGH ROOF OVER STAIRWAY

VESTIBULE. CHIP, GRIND, & PATCH EXISTING CONC. TO CREATE UNIFORMITY SMOOTH

SUBSTRATE.

11. APPLY WATERPROOFING TYPE WP-1 ON SLOPED REPAIR MORTAR TO TOP OF EXISTING

SHELTER ROOF / STAIRWAY VESTIBULE HIGH ROOF.

12. PERIMETER DRAIN AT 24” BELOW EDGE OF SHELTER ROOF - TYPICAL ALL SIDES. SEE CIVIL

DWGS FOR DETAIL. REFER TO WATERPROOFING DETAIL INDICATED.

13. EXISTING CATCH BASIN - SEE CIVIL DWGS.

14. CONNECT PERIMETER DRAIN TO EXISTING CATCH BASIN - SEE CIVIL DWGS.

15. EXTEND PERIMETER DRAIN UNDER EQUIPMENT CORRAL WALL - SEE CIVIL DWGS.

16. FLASH WATERPROOFING MEMBRANE TO EXISTING STL. TUBE POSTS PER TYPICAL DETAILS.

17. APPLY WATERPROOFING TYPE WP-2 TO BELOW-GRADE FACE OF NEW OR EXISTING

FOUNDATION WALLS WHEREVER INDICATED WITH HEAVY DASHED LINE, TYPICAL. EXTEND

WATERPROOFING ON ALL SURFACES EXPOSED TO EARTH DOWN TO BOTTOM OF FOOTING /

UNDERPINNING FOR EACH WALL (EXTENT OF WATERPROOFING ON FOOTINGS IS NOT

DEPICTED FOR CLARITY). REFER TO TYPICAL FOUNDATION WALL WATERPROOFING DETAIL.

REFER TO ARCH. AND STRUCT. DWGS FOR WALL AND FOOTING / UNDERPINNING DEPTHS

AND DETAILS.

18. EXISTING UNDERGROUND UTILITIES IN AREA OF WORK - SEE CIVIL DWGS.

19. EXISTING METAL FIRE ESCAPE STAIR UP. SHORE AND SUPPORT IN PLACE - SEE CIVIL DWGS.

20. APPLY WATERPROOFING SYSTEM TYPE WP-2 TO BELOW-GRADE PORTION OF EXISTING

COURTHOUSE WALL AND TIE TO SPECIFIED WATERPROOFING SYSTEM ON SHELTER ROOF.

REFER TO WATERPROOFING DETAILS.

21. WATERPROOF JOINT BETWEEN NEW CONC. UTILITY TUNNEL AND FACE OF EXISTING CONC.

FOUNDATION WALL . SEE DWG BE1.3 FOR ADDITIONAL INFORMATION.

BE1.3

A

D

BE2.1 SIM.

D

BE2.1

C

BE1.3

BE2.1

G

SIM.

17 17 17

NOT FOR BID

DIN

G

OR C

EXCAVATE, BACKFILL, GRADE AND

SOD

HEMMED 16 OZ COPPER COUNTERFLASHING . EXTEND 4 INCHES

BELOW GRADE.

WATERPROOFING TYPE WP-2 ON EXISTING BRICK FOUNDATION

WALL. PREPARE SUBSTRATE PER MFR. RECEOMMENDATIONS

UNDISTURBED

SUBGRADE

EXISTING SHELTER ROOF

EXISTING

CONCRETE WALL

WATERPROOFING TYPE WP-1 ON EXISTING CONC.

SHELTER ROOF. PREPARE SUBSTRATE PER MFR.

RECEOMMENDATIONS

EXTEND COUNTERFLASHING INTO SAWCUT REGLET IN EXSTG. BRICK

BED JOINT. SECURE WITH LEAD WEDGES. POINT W/ MORTAR

TERMINATION BAR, RECOMMENDED FASTENERS & SEALANT CAP

BEAD

2'0"

TYP.

4' -0

TY

P.

TY

P.

LI

NE

O F R

OO

F C

AN

T

EX. SLOPE EX. SLOPE

SHELTER ROOF BELOW

2' -0

TY

P.

2' -0

TY

P.

2'-0"

TYP.

2'-0"

TYP.

2' -0

TY

P.

WATERPROOFING PLAN - ALTERNATE NO. 1A

BE1.2

Torchio Architects, Inc.

COPYRIGHT C

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, License Number 14756, Expiration Date 10/23/2026 James I. Magnuson

BECS PROJECT NUMBER:

Building Envelope Consultants and Scientists, LLC.

BECS

Maryland Office 875 Hollins Street, #201 Baltimore, MD 21213 443-873-6203 www.becsmd.com

20230564

AKMH / JM

Design By:

NOVEMBER 01, 2025

A2112

Q

UE

EN

A

NN

E'S

C O

UN

TY

100% CONSTRUCTION

DOCUMENTS

JM

HI

ST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

SCALE: 1/8"=1'-0"

PLAN NORTH

BE1.2

W

AT

ER

PR

O O

FIN

G

P

LA

N

- A

LT

ER

NA

TE

N O

. 1

EX. CURB (TYP.)

EX. BRICK WALK ABOVE (TYP.)

NORTH LIBERTY STREET

NO

RT

H

LIB

ER

TY

ST

RE

ET

BR

OA

DW

AY

FINISHED GRADE

6" 1'

-6

VARIES - SEE PLAN

WATERPROOFING AT SHELTER ROOF AND WALL INTERSECTION ALTERNATE NO. 1B

BE1.2 SCALE: 1 1/2"=1'-0"

BASEMENT LEVEL COURTHOUSE

WATERPROOFING - INCLUDED IN

BASE SCOPE OF WORK - SEE A/BE1.1

B

BE1.2

TYP.

4"

EX. CATCH BASIN - SEE CIVIL DRAWINGS

EXCAVATE 2'-0" BEYOND WATERPROOFING

KEY NOTES (ALTERNATE NO. 1 - BE1.2):

1. APPLY WATERPROOFING TYPE WP-1 TO PORTION OF EXISTING SHELTER ROOF AND

TYPE WP-2 TOP EXISTING FOUNDATION WALL - SEE B/BE1.2. EXCAVATE AS

NECESSARY, BACKFILL, & RE-GRADE.

2. DEMOLISH EXISTING CONC. CURB DOWN TO THE TOP OF THE HIGH ROOF OVER

STAIRWAY VESTIBULE. CHIP, GRIND, & PATCH EXISTING CONC. TO CREATE

UNIFORMITY SMOOTH SUBSTRATE. EXCAVATE AS NECESSARY, BACKFILL, &

RE-GRADE.

3. APPLY WATERPROOFING TYPE WP-1 ON LIMITED AREA OF SHELTER ROOF AFTER

DEMOLITION OF CONC. CURB - SEE A/BE1.2. ATTACH EDGES OF MEMBRANE TO

SUBSTRATE WITH TERMINATION BAR AND MFR. RECOMMENDED SEALANT.

EXCAVATE AS NECESSARY, BACKFILL, & RE-GRADE.

5. APPLY WATERPROOFING TYPE WP-1 TO TOP ONLY OF NEW BELOW GRADE UTILITY

TUNNEL - SEE A/BE1.2. FASTEN EDGES WITH TERMINATION BAR AND MFR

RECOMMENDED SEALANT CAP BEAD. SEE ARCH AND STRUCT DWGS FOR TUNNEL.

EXCAVATE AS NECESSARY, BACKFILL, & RE-GRADE.

6. APPLY WATERPROOFING TYPE WP-2 TO UNDERGROUND PORTION OF NEW

VERTICAL CONC. UTILITY CHASE - SEE B/BE1.2. TERMINATE EDGES OF MEMBRANE

WITH TERMINATION BAR AND MANUFACTURER RECOMMENDED SEALANT CAP

BEAD 4 INCHES BELOW FINISHED GRADE. EXCAVATE AS NECESSARY, BACKFILL, &

RE-GRADE.

7. EXTEND WATERPROOFING TYPE WP-2 UP THIS PORTION OF OUTSIDE EXISTING

STAIR ENCLOSURE WALL AND FLASH INTO MORTAR JOINT IN NEW BRICK COPING -

SEE ARCH DWGS FOR BRICK COPING. REFER TO WATERPROOFING DETAIL

INDICATED. EXCAVATE AS NECESSARY, BACKFILL, & RE-GRADE.

8. WATERPROOF JOINT BETWEEN NEW UTILITY TUNNEL AND FACE OF EXISTING

BELOW-GRADE CONC. STAIR WALL PER DETAIL J/BE2.1. EXCAVATE AS NECESSARY,

BACKFILL, & RE-GRADE.

9. EXTEND WP-1 MEMBRANE BENEATH EXISTING BRICK WALL OF UTILITY ENCLOSURE

TO REMAIN. TEMPORARILY SHORE, REMOVE, SALVAGE & REINSTALL BOTTOM

PORTION OF BRICK WALL FOR WATERPROOFING INSTALLATION. SEE DETAIL

INDICATED. EXCAVATE AS NECESSARY, BACKFILL, & RE-GRADE.

10. APPLY WATERPROOFING TYPE WP-1 TO LIMITED AREA OF SHELTER ROOF BENEATH

EXISTING EQUIPMENT CORRAL AS INDICATED. TERMINATE EDGES OF MEMBRANE

WITH TERMINATION BAR AND MANUFACTURER RECOMMENDED SEALANT CAP

BEAD. EXCAVATE AS NECESSARY, BACKFILL, & RE-GRADE.

11. INJECT SPECIFIED RESIN WATERPROOFING PER MFR. RECOMMENDATIONS INTO ALL

CRACKS AND COLD JOINTS IN EXISTING CONCRETE SUBSTRATE BEFORE

INSTALLATION OF WATERPROOFING.

12. FLASH WATERPROOFING MEMBRANE TO EXISTING STL. TUBE POSTS PER TYPICAL

DETAILS.

13. EXISTING METAL FIRE ESCAPE STAIR UP. SHORE AND SUPPORT IN PLACE - SEE CIVIL

DWGS.

14. APPROXIMATE LIMIT OF EXCAVATION AREA FOR WATERPROOFING INSTALLATION

INDICATED AS A DASHED LINE.

2 3

J

BE2.1

C

BE1.3

SIM.

10 11

BE2.1

G

1 12" MIN.

NOT FOR BID

DIN

G

OR C

Torchio Architects, Inc.

COPYRIGHT C

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, License Number 14756, Expiration Date 10/23/2026 James I. Magnuson

BECS PROJECT NUMBER:

Building Envelope Consultants and Scientists, LLC.

BECS

Maryland Office 875 Hollins Street, #201 Baltimore, MD 21213 443-873-6203 www.becsmd.com

20230564

AKMH / JM

Design By:

NOVEMBER 01, 2025

A2112

Q

UE

EN

A

NN

E'S

C O

UN

TY

100% CONSTRUCTION

DOCUMENTS

JM

HI

ST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

SL

OP

E

SLOPE

PLAN NORTH

MORTAR HI POINT

+ 2 12" ABOVE EXSTG. CONC.

MORTAR LOW POINT

+ 12" ABOVE EXSTG. CONC.

MORTAR LOW POINT

+ 12" ABOVE EXSTG. CONC.

EX

ST

G.

ST

AI

R

DO

W

N

TO

B

AS

EM

EN

T

LV

L.

WATERPROOFING DETAIL PLANA

BE1.3 SCALE: 1/4"=1'-0"

BE1.3

C

BE1.3

B

BE2.1

D

EXSTG. COURTHOUSE

REMOVE & DISPOSE OF EXSTG/ CONC. CURB DOWN TO

TOP OF EXSTG. UNDERGROUND SHELTER

EDGE OF EXSTG. UNDERGROUND SHELTER

TYPICAL PERIMETER DRAIN

NEW BRICK COPING & GUARD RAIL ATOP EXSTG. CONC.

RETAINING WALL - SEE ARCH. AND CIVIL DWG.

WATERPROOFING TYPE WP-1 ON

SLOPED REPAIR MORTAR TO TOP

OF EXSTG. SHELTER ROOF. MAX.

THICKNESS 2 1/2 INCHES / MIN. 12

INCH

LIMIT OF REPAIR MORTAR

CHANGE IN REPAIR MORTAR SLOPE

WATERPROOFING TYPE WP-1 ON

EXSTG. SHELTER ROOF

WATERPROOFING TYPE WP-1 ON TOP AND WP-2 ON SIDE

OF NEW CONC. UTILITY TUNNEL. SEE ARCH AND STRUCT

DWGS FOR UTILITY TUNNEL

EXSTG. BRICK WALL OF UTILITY ENCLOSURE TO REMAIN.

DO NOT UNDERMINE OR DAMAGE DURING EXCAVATION

AND WATERPROOFING WORK.

EXTEND WATERPROOFING TYPE

WP-1 BENEATH EXISTING BRICK

WALL - SEE DETAIL INDICATED.

NEW VERTICAL CONC. UTILITY CHASE - SEE ARCH. DWGS.

TURN-UP WATERPROOFING TYPE WP-2 ON OUTSIDE OF

UTILITY CHASE. TERMINATE 4 INCHES BELOW FNISHED

GRADE W/ TERMINATION BAR AND SEALANT CAP BEAD

SL

OP

E

WATERPROOFING TYPE WP-1 ON SLOPED REPAIR MORTAR

TO TOP OF EXSTG. SHELTER ROOF. MAX. THICKNESS 2 1/2

INCHES / MIN. 12 INCH

WATERPROOFING SECTIONB

BE1.3 SCALE: 1/4"=1'-0"

BE2.1

C SIM.

OMIT INSULATIONBE2.1

E

BE2.1

D

SLOPED REPAIR MORTAR. REMOVE EXSTG.

WATERPROOFING AND MECHANICALLY PROFILE

EXSTG. CONC. PER MFR. RECOMMENDATIONS.

WHERE MORTAR EXCEEDS 1 INCH THICKNESS,

EXTEND MORTAR WITH 38" PEA GRAVEL AT A RATE

OF 30 LBS GRAVEL TO 50 LBS DRY MORTAR MIX.

WATERPROOFING TYPE WP-1

EXCAVATE, STOCKPILE, BACKFILL & RE-GRADE -

SEE CIVIL DWGS.

BRICK COPING & GUARD

ATOP EXSTG. CONC.

RETAINING WALL - SEE

ARCH. DWGS.

W

AT

ER

PR

O O

FIN

G

D

ET

AI

L P

LA

N

AN

D

SE

CT

IO

NS

WATERPROOFING SECTIONC

BE1.3 SCALE: 1/4"=1'-0"

BE2.1

C SIM.

SEQUENTIALLY SHORE, REMOVE, SALVAGE, &

REINSTALL BOTTOM COURSES OF EXSTG. BRICK IN

3 FOOT SECTIONS FOR INSTALLATION OF

WATERPROOFING. PROVIDE INTERMITTENT GAPS

IN BOTTOM OF WALL TO ALLOW DRAINAGE AS

INDICATED IN THE DETAIL.

EXSTG. BRICK SITE WALL AROUND EQPT. CORRAL

TO REMAIN

EXSTG. CONC. SHELTER ROOF & WALL

WATERPROOFING WP-1 SEE A/BE1.2

CONC. UTILITY TUNNEL - SEE ARCH. & STRUCT.

DWGS.

BE2.1

FBE2.1

C SIM.

BE2.1

J

BE2.1

C SIM.

PERIMETER DRAIN

BE1.3

OPP

GUARD RAIL POST PENETRATION - SEE ARCH. DWGS. FOR

GUARD. FLASH PER E/BE2.1.

SIM.

NOT FOR BID

DIN

G

OR C

FINISHED GRADE

WATERPROOFING AT COURTHOUSE WALLD

BE2.1 SCALE:1 12" = 1'-0"

WATERPROOFING TYPE WP-1A

BE2.1 SCALE:1 12" = 1'-0"

WATERPROOFING AND BRICK CURB @ STAIRE

BE2.1 SCALE:1 12" = 1'-0"

WATERPROOFING TYPE WP-2B

BE2.1 SCALE:1 12" = 1'-0"

WATERPROOFING AND PERIMETER DRAINC

BE2.1 SCALE:1 12" = 1'-0"

EXISTING

CONCRETE

SHELTER WALL

EXISTING SHELTER ROOF

UNDISTURBED

SUBGRADE

LIMIT EXCAVATION TO

EXTENT NECESSARY FOR

WATERPROOFING WORK -

TYP.

FILTER FABRIC & #57

DRAINAGE FILL. PROVIDE

MIN. 3 INCH COVER AROUND

PIPE

TERMINATION BAR.

WATERPROOFING TYPE

WP-2 - SEE B/BE2.1

CHAMFER CONCRETE 2"x2"

LAP AND WELD WP-1 AND

WP-2 MEMBRANES PER MFR.

RECOMMENDATIONWATERPROOFING

TYPE WP-1 - SEE

A/BE2.1

1' -4

DE

PT

H

VA

RI

ES

BACKFILL, REGRADE AND RE-SOD - COORDINATE

EXCAVATION AND BACKFILL WITH CIVIL DRAWINGS

ADDITIONAL MEMBRANE -

REFER TO CIVIL DWGS.

EXISTING SHELTER ROOF

EXISTING BRICK

WALL

EXCAVATE, BACKFILL, GRADE AND

SOD

6" 1'

-6

4"

WATERPROOFING AT EXISTING EXTERIOR WALL WITHIN CORRALF

BE2.1 SCALE:1 12" = 1'-0"

DATUM: TOP OF

WALL/ UNDERSIDE

OF ROOF

BOTTOM OF

WATERPROOFING

FINISHED GRADE

3" 3"

EXISTING SOIL OVERBURDEN - EXCAVATE FOR WATERPROOFING THEN BACKFILL & RE-GRADE. REFER TO CIVIL

DWGS. FOR INFORMATION

R-10 MINIMUM RIGID FOAM INSULATION CONTINUOUS WITHOUT VOIDS OR GAPS. BUTT EDGES AND TIGHTLY

CUT AND COPE TO ADJACENT CONSTRUCTION AND PENETRATIONS.

DRAINAGE AND PROTECTION BOARD, CONTINUOUS.

DUAL PVC AND REACTIVE POLYMER FLEECE (RPF) SHEET WATERPROOFING. RPF LAYER SHOWN DASHED.

LOOSE-LAID.

INJECT SPECIFIED RESIN WATERPROOFING PER MFR. RECOMMENDATIONS INTO ALL CRACKS AND COLD JOINTS IN

EXSTG. CONCRETE SUBSTRATE BEFORE INSTALLATION OF WATERPROOFING

EXISTING CONCRETE SUBSTRATE. REMOVE SOIL,

ROCKS, LOOSE AND SPALLED CONCRETE, AND LOOSE

PORTIONS OF EXISTING ASPHALTIC WATERPROOFING

TO EXTENT RECOMMENDED BY WATERPROOFING

MEMBRANE MANUFACTURER. FULL REMOVAL OF

EXISTING WATERPROOFING IS NOT REQUIRED. MAKE

CONCRETE REPAIRS WHERE NECESSARY, AND

PREPARE SURFACE AS RECOMMENDED BY

WATERPROOFING MFR.

TYPICAL WATERPROOFING EDGE SEAM:

(1) CUT AND EXPOSE 3 INCHES OF RPF ALONG EDGE

OF "DOWNHILL" SHEET.

(2) REMOVE 3 INCHES OF RPF FROM EDGE OF

"UPHILL" SHEET.

(3) LAP UPHILL SHEET OVER DOWNHILL SHEET,

ACHIEVING OVERLAP DISTANCES INDICATED.

(4) HEAT WELD UPHILL SHEET TO DOWNHILL SHEET,

MINIMUM OF 12" WIDE WELD.

EXISTING SOIL OVERBURDEN - EXCAVATE FOR WATERPROOFING THEN BACKFILL & RE-GRADE. REFER

TO CIVIL DWGS. FOR INFORMATION

R-10 MINIMUM RIGID FOAM INSULATION CONTINUOUS WITHOUT VOIDS OR GAPS. BUTT EDGES AND

TIGHTLY CUT AND COPE TO ADJACENT CONSTRUCTION AND PENETRATIONS.

DRAINAGE AND PROTECTION BOARD, CONTINUOUS.

ADHERED REINFORCED THERMOPLASTIC FLASHING MEMBRANE.

INJECT SPECIFIED RESIN WATERPROOFING PER MFR. RECOMMENDATIONS INTO ALL CRACKS AND COLD

JOINTS IN EXSTG. CONCRETE SUBSTRATE BEFORE INSTALLATION OF WATERPROOFING

EXSTG. CONCRETE SUBSTRATE. CLEAN, INSPECT & REPAIR, AND PREPARE PER WATERPROOFING MFR.

RECOMMENDATIONS.

FLASHING AT TUBE POST WITH BASEPLATEG

BE2.1 SCALE:1 12" = 1'-0"

WATERPROOFING AT NEW FOUNDATION WALL & UNDERPINNINGH

BE2.1 SCALE:1 12" = 1'-0"

WATERPROOFING TYPE WP-2 (OMIT

INSULATION)

MANUF. APPLIED SEALANT ALONG

TOP EDGE.

TERMINATION BAR

MANUF. APPLIED SEALANT

CANT PER WATERPROOFING

MFR. RECOMMENDATIONS

INJECT SPECIFIED RESIN WATERPROOFING PER MFR. RECOMMENDATIONS INTO

ALL CRACKS AND COLD JOINTS IN EXSTG. CONCRETE SUBSTRATE BEFORE

INSTALLATION OF WATERPROOFING

EXISTING SHELTER ROOF

EXISTING

CONCRETE WALL

EXCAVATE, BACKFILL,

GRADE AND SOD

WATERPROOFING TYPE WP-1 SEE A/BE2.1

SEALANT CAP BEAD ALL AROUND

EXCAVATE, BACKFILL,

GRADE AND SOD

EXISTING SHELTER ROOF

4"

TERMINATION BAR

MANUF. APPLIED SEALANT CAP BEAD ALONG TOP EDGE

EXISTING METAL STAIR TUBE

HEMMED 16 OZ COPPER COUNTERFLASHING . EXTEND 4 INCHES

BELOW GRADE.

WATERPROOFING TYPE WP-2 ON EXISTING BRICK FOUNDATION

WALL. PREPARE SUBSTRATE PER MFR. RECEOMMENDATIONS

WATERPROOFING TYPE WP-1 ON EXISTING CONC.

SHELTER ROOF. PREPARE SUBSTRATE PER MFR.

RECEOMMENDATIONS

COUNTERFLASHING IN SAWCUT REGLET IN EXSTG. BRICK BED JOINT.

SECURE WITH LEAD WEDGES. POINT W/ MORTAR.

TERMINATION BAR, RECOMMENDED FASTENERS & SEALANT CAP

BEAD

EXCAVATE,

BACKFILL,

GRADE AND

SOD

EXISTING SHELTER ROOF

WP-1 MEMBRANE CONTINUOUS UNDER EXSTG. BRICK SITE WALL

LAMINATED STAINLESS STEEL FLASHING MEMBRANE AS SEPARATOR BETWEEN

BRICK AND WP-1 MEMBRANE

SEQUENTIALLY SHORE, REMOVE, SALVAGE, AND

REINSTALL BOTTOM COURSES OF EXSTG. BRICK IN

APPROX. 3 FOOT INTERMITTENT SECTIONS FOR

INSTALLATION OF WP-1 MEMBRANE. LAP AND HEAT

WELD ADJACENT WP-1 MEMBRANE SECTIONS

WATERTIGHT AS INDICATED IN DETAIL A/BE2.1.

WATERPROOFING TYPE WP-1 SEE A/BE1.2

EXSTG. BRICK SITE WALL AROUND EQPT. CORRAL TO

REMAIN

STOP DRAINAGE AND PROTECTION BOARD AND

INSULATION AT FACE OF WALL

WATERPROOFING TYPE WP-2 (OMIT INSULATION) SEE B/BE2.1

WATERPROOFING TYPE WP-1 SEE A/BE2.1

LAMINATED STAINLESS STEEL FLASHING EMBEDDED IN MORTAR BED

JOINT - FULL WIDTH OF WALL

TRANSITION TO HEMMED MILL STAINLESS STL. COUNTERFLASHING

AT EXTERIOR FACE OF WALL

PERFORATED PERIMETER

DRAIN - SEE CIVIL DWGS.

FIELD-FORMED PENETRATION FLASHING

BOOT - UNREINFORCED KEE DETAIL

MEMBRANE BY WATERPROOFING

MANUFACTURER. HEAT-WELD TO TOP OF

WP-1 MEMBRANE, AND ADHERE TO EXSTG.

STEEL TUBE.

" M

IN

CONCRETE UNDERPINNING

BY OTHERS. SEE STRUC.

DWG.

TERMINATION BAR

VA

RI

ES

SE

E

AR

CH

. A

ND

ST

RU

CT

. D

W

GS

VA

RI

ES

SE

E

AR

CH

. D W

GS

WATERPROOFING AT UTILITY TUNNEL / EXISTING STAIR WALLJ

BE2.1 SCALE:1 12" = 1'-0"

EXCAVATE, BACKFILL,

GRADE AND SOD

SEMI-CONDITIONED INTERIOR

SPACE BELOW EXISTING CONC.

STAIR

EXSTG. CONC. FOUNDATION

WALL & STAIR

STRIP-FLASH JOINT BETWEEN NEW &

EXSTG. CONC. W/ ADHERED

UNREINFORCED KEE DETAIL FLASHING

MEMBRANE. EXTEND 6 INCHES TO EITHER

SIDE OF JOINT.

NEW UTILITY OPNG. THRU EXSTG. WALL -

SEE MEP AND ARCH DWGS

TOP OF CONC. UTILITY TUNNEL - SEE

STRUCT. DWGS.

WATERPROOFING TYPE WP-1 SEE

A/BE2.1

LAP & HEAT-WELD WP-2 MEMBRANE

TO TOP OF WP-1 MEMBRANE PER MFR.

RECOMMENDATIONS

WATERPROOFING TYPE WP-2 SEE

B/BE2.1

TERMINATE TOP OF WP-2 SIMILAR TO DETAIL E/BE2.1 AT 4 INCHES BELOW FINISHED

GRADE

EXCAVATE & BACKFILL FOR

WATERPROOFING (SOILS NOT

SHOWN)

EXCAVATE & BACKFILL FOR

WATERPROOFING (SOILS NOT

SHOWN)

1 12"MIN.

NOTE: PROVIDE INTERMITTENT

OPENINGS THROUGH BOTTOM OF

BRICK WALL FOR WATER DRAINAGE - 8

INCHES WIDE x 2 BRICK COURSES HIGH, EVERY 24 INCHES.

FIELD-FORMED

PENETRATION FLASHING

BOOT - UNREINFORCED

KEE DETAIL MEMBRANE BY

WATERPROOFING

MANUFACTURER. ADHERE

TO POST AND TO TOP OF

LAMINATED S.STL.

FLASHING. SEAL

WATERTIGHT.

GUARD RAIL POSTS EMBEDDED IN EXSTG. WALL - SEE

ARCH. DWGS. FOR DESCRIPTION

SEALANT COVE BEAD

BRICK - SEE ARCH. DWGS.

Torchio Architects, Inc.

COPYRIGHT C

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, License Number 14756, Expiration Date 10/23/2026 James I. Magnuson

BECS PROJECT NUMBER:

Building Envelope Consultants and Scientists, LLC.

BECS

Maryland Office 875 Hollins Street, #201 Baltimore, MD 21213 443-873-6203 www.becsmd.com

20230564

AKMH / JM

Design By:

NOVEMBER 01, 2025

A2112

Q

UE

EN

A

NN

E'S

C O

UN

TY

100% CONSTRUCTION

DOCUMENTS

JM

HI

ST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

BE2.1

W

AT

ER

PR

O O

FIN

G

D

ET

AI

LSNOT FOR BID

DIN

G

OR C

File details come from the government source that posted it. Updated .