drawing - FIRE ALARM_QAC Historic Courthouse RFQ_2026.07.01.pdf

PDF 2 MB Posted

Attached to
Historic Courthouse Renovation
Solicitation number
BPM057809
Issued by
Queen Anne's County, Maryland

About this file

This is a fire alarm system drawing for the Historic Courthouse renovation project in Queen Anne's County, Maryland. The drawing provides technical specifications and layout details for the fire alarm installation as part of the comprehensive renovation of the 17,800-square-foot Historic Courthouse located at 100 Courthouse Square in Centreville. The fire alarm system represents one component of the electrical and life safety systems being newly installed in the building, which will include a new electrical service, back-up power generator, lightning protection, and other integrated building systems. The drawing serves as a reference document for general contractors and subcontractors bidding on or executing the construction work to understand the fire alarm system design, placement, and integration requirements within the overall renovation scope.

The fire alarm drawing is a technical specification document that does not independently address pricing terms, contract set-asides, incumbent information, or funding details. This drawing functions as a supporting exhibit to the Request for Qualifications (RFQ) for General Contractor services and should be reviewed in conjunction with the primary RFQ documents, bid specifications, and project scope of work to obtain complete information regarding cost requirements, project timeline, and award criteria for the Historic Courthouse renovation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Torchio Architects, Inc.

COPYRIGHT C

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

A2112

Q

AC

H

IST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

06.05.26

PROGRESS SET

NOT FOR CONSTRUCTION

FA001

FIR

E A

LA

RM

C O

VE

R

SH

EE

T

REFERENCE

PRESENTATION

FIRE ALARM

FIRE ALARM CONVENTIONS

SPECIAL NOTE (APPLIES WHERE INDICATED ON THE DRAWING)1

FIRE ALARM EQUIPMENT DESIGNATED BY SOLID HEAVY

LINEWEIGHT INDICATES NEW WORK TO BE PROVIDED.

FIRE ALARM EQUIPMENT DESIGNATED BY SOLID LIGHT

LINEWEIGHT INDICATES EXISTING EQUIPMENT TO REMAIN,

UNLESS OTHERWISE INDICATED.

FIRE ALARM EQUIPMENT DESIGNATED BY DASHED HEAVY

LINEWEIGHT REPRESENTS EXISTING EQUIPMENT TO BE

REMOVED AND DISPOSED, UNLESS INDICATED TO BE

REMOUNTED, RELOCATED, OR TURNED OVER TO OWNER.

CANDELA RATING

DEVICE TYPE

15cd

NOTES: (APPLICABLE TO FIRE ALARM LEGEND ONLY)

1. THE MOUNTING HEIGHTS GIVEN ON THIS SHEET IN THE FIRE ALARM LEGEND ARE GENERAL AND SHALL BE

USED ONLY WHEN MOUNTING HEIGHTS CANNOT BE ESTABLISHED BY REFERENCE TO DETAILS,

ELEVATIONS, AND NOTES ON THE DRAWINGS.

2. ALL MOUNTING HEIGHTS, UNLESS OTHERWISE NOTED, SHALL BE MEASURED FROM THE FINISHED FLOOR

TO THE CENTERLINE OF THE OUTLET OR DEVICE.

3. HEIGHTS OF ALL ITEMS NOT COVERED BY THE FIRE ALARM LEGEND AND NOT SHOWN ON THE DRAWINGS

SHALL BE AS DIRECTED BY THE ARCHITECT OR ENGINEER.

4. WHERE PLACING ANY ITEM AT THE HEIGHTS LISTED OR NOTED WILL CAUSE INTERFERENCE WITH THE WORK OF OTHER TRADES, OR IS NOT PHYSICALLY POSSIBLE OR DESIRABLE FOR ONE REASON OR ANOTHER, THE ITEM SHALL BE INSTALLED AT A LOCATION APPROVED BY THE ARCHITECT OR ENGINEER.

FIRE ALARM SYSTEM - SMOKE DETECTOR - AREA, CEILING/WALL MOUNT

SUBSCRIPTS:

P: PHOTOELECTRIC TYPE (DEFAULT IF NO SUBSCRIPT INDICATED)

I: IONIZATION TYPE

E: ELEVATOR RECALL FUNCTION

SEE DETAIL

SS

FIRE ALARM ADDRESSABLE MODULE 78" TO TOPAM

SYMBOL DESCRIPTION MOUNTING

HEIGHT

FIRE ALARM LEGEND

SEE DETAIL

FIRE ALARM SYSTEM - HEAT DETECTOR, CEILING/WALL MOUNT

SUBSCRIPTS:

F: FIXED TEMPERATURE (DEFAULT IF NO SUBSCRIPT INDICATED)

FIRE ALARM SYSTEM - SPRINKLER FLOW DETECTION SWITCH - -FS

FIRE ALARM SYSTEM - MANUAL FIRE ALARM BOX 46"F

86"FIRE ALARM SYSTEM - BELL

- - / 86"

FIRE ALARM SYSTEM - STROBE, CEILING/WALL MOUNT

SUBSCRIPTS:

WP: WEATHERPROOF

WG: WIRE GUARD

- - / 86"

FIRE ALARM SYSTEM - LOUDSPREAKER , CEILING/WALL MOUNT

SUBSCRIPTS:

WP: WEATHERPROOF

WG: WIRE GUARD

EP: EXPLOSION PROOF

FIRE ALARM SYSTEM - FIRE ALARM CONTROL PANEL 78" TO TOPFACP

TWO-WAY EMERGENCY COMMUNICATIONS SYSTEM FOR RESCUE

ASSISTANCE – CALL STATION 46"AR

FIRE ALARM SYSTEM DOCUMENTATION CABINET --FADC

FIRE ALARM SYSTEM - VALVE WITH TAMPER DETECTION SWITCH - -TS

BVT

A AMPERE

ADA AMERICANS WITH DISIBILITIES ACT

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AGM ABSORBED GLASS MAT

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

AIM ADDRESSABLE INTERFACE MODULE

ANSI AMERICAN NATIONAL STANDARDSINSTITUTE

AWG AMERICAN WIRE GAUGE

BDA BI-DIRECTIONAL AMPLIFIER

BLDG BUILDING

BOD BASIS OF DESIGN

C CONDUIT

CB CIRCUIT BREAKER

CD CANDELA

CI CIRCUIT INTEGRITY

CLG CEILING

CMU CONCRETE MASONRY UNIT

CO CARBON MONOXIDE

COMM COMMUNICATIONS

CX CONNECT TO EXISTING

DACT DIGITAL ALARM

COMMUNICATORTRANSMITTER

DAS DISTRIBUTED ANTENNA SYSTEM

DB DECIBEL

DN DOWN

DOAS DEDICATED OUTDOOR AIR SYSTEM

DWG DRAWING

E EMERGENCY

ECS EMERGENCY COMMUNICATIONSSYSTEM

EMR ELEVATOR MACHINE ROOM

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EQUIP EQUIPMENT

ERCCS EMERGENCY

RESPONDERCOMMUNICATIONS

COVERAGESYSTEM

ERCES EMERGENCY RESPONDERCOMMUNICATIONS

ENHANCEMENTSYSTEM

ERRCS EMERGENCY RESPONDER RADIOCOVERAGE

SYSTEM

ETR EXISTING TO REMAIN

EVACS EMERGENCY

VOICE/ALARMCOMMUNICATIONS

SYSTEMEX EXISTING

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FACU FIRE ALARM CONTROL UNIT

FAID FIRE ALARM INITIATING DEVICE

FEO FIREFIGHTERS'

EMERGENCYOPERATION

FMC FLEXIBLE METAL CONDUIT

FSAE FIRE SERVICE ACCESS ELEVATOR

FT FEET

G GROUND

GND GROUND

GW GROUND WIRE

HLI HIGH LEVEL INTERFACE

HVAC HEATING VENTILATING

AIRCONDITIONING

HVI HEARING AND VISUALLY IMPAIRED

HZ HERTZ

IBC INTERNATIONAL BUILDING CODE

IDC INITIATING DEVICE CIRCUIT

FIRE ALARM ABBREVIATIONS

IEBC INTERNATIONAL EXISTING BUILDINGCODE

IFC INTERNATIONAL FIRE CODE

IN INCH

JB JUNCTION BOX

LCD LIQUID CRYSTAL DISPLAY

LED LIGHT EMITTING DIODE

MAX MAXIMUM

MI MINERAL INSULATED

MIN MINIMUM

MNS MASS NOTIFICATION SYSTEM

MTD MOUNTED

NAC NOTIFICATION APPLIANCE CIRCUIT

NC NORMALLY CLOSED

NCP NETWORK CONTROL PANEL

NEC NATIONAL ELECTRICAL CODE

NECA NATIONAL ELECTRICALCONTRACTORS'

ASSOCIATION

NEMA NATIONAL ELECTRICALMANUFACTURERS'

ASSOCIATION

NESC NATIONAL ELECTRICAL SAFETY CODE

NFPA NATIONAL FIRE

PROTECTIONASSOCIATION

NIC NOT IN CONTRACT

NICET NATIONAL INSTITUTE FORCERTIFICATION IN

ENGINEERINGTECHNOLOGIES

NO NUMBER, NORMALLY OPEN

NPLFA NON-POWER LIMITED FIRE ALARM

NTS NOT TO SCALE

OC ON CENTER

OEE OCCUPANT EVACUATION ELEVATOR

OSHA OCCUPATIONAL SAFETY AND

HEALTHADMINISTRATION

P POLE, PHASE

PA PUBLIC ADDRESS

PC PERSONAL COMPUTER

PH PHASE

PLC POWER LIMITED CIRCUIT

PLFA POWER-LIMITED FIRE ALARM

POE POWER OVER ETHERNET

PVC POLYVINYL CHLORIDE

PWR POWER

QTY QUANTITY

R RACEWAY

RA RETURN AIR

RM ROOM

RTU ROOF TOP UNIT

RX REMOVE EXISTING

SA SUPPLY AIR

SF SQUARE FEET

SLC SIGNALING LINE CIRCUIT

SPD SURGE PROTECTION DEVICE

TYP TYPICAL

UG UNDERGROUND

UL UNDERWRITER'S LABORATORY

UON UNLESS OTHERWISE NOTED

V VOLTS

VRLA VALVE REGULATED LEAD ACID

W WIRE, WATTS

W/ WITH

WP WEATHERPROOF

FIRE ALARM SYSTEM - FIRE ALARM SYSTEM ANNUNCIATOR PANEL 78" TO TOPFAAP

TWO-WAY EMERGENCY COMMUNICATIONS SYSTEM FOR RESCUE

ASSISTANCE – ANNUNCIATOR PANEL / MASTER STATION 78" TO TOPARAP

FIRE ALARM SYSTEM - MAGNETIC DOOR HOLDER COORDINATE

W/ DOOR

DH

GENERAL FIRE ALARM NOTES

1. VERIFY THAT EXISTING FIRE ALARM SYSTEM IS OPERATIONAL BEFORE MAKING CHANGES OR CONNECTIONS.

2. DO NOT INTERRUPT EXISTING FIRE ALARM SYSTEM WITHOUT [CONTRACTING OFFICER'S] [OWNER'S] [OWNER'S REPRESENTATIVE'S] [ENGINEER'S] [ARCHITECT'S] WRITTEN

PERMISSION.

3. DRAWINGS ARE CONCEPTUAL, INTENDED TO SHOW GENERAL SYSTEM CONFIGURATION AND PERFORMANCE. PREPARE SHOP DRAWINGS AND PROVIDE CONDUITS, WIRING, SYSTEM COMPONENTS AND EQUIPMENT FOR A COMPLETE AND OPERATIONAL SYSTEM IN COMPLIANCE WITH NFPA 70, NFPA 72, NFPA 90A, NFPA 101 IBC, THE

AUTHORITY HAVING JURISDICTION AND THE CONTRACT DOCUMENTS.

4. SCHEDULE PRELIMINARY REVIEW WITH FIRE MARSHAL. COORDINATE FIRE ALARM WORK WITH LOCAL FIRE MARSHAL, FIRE ALARM PLANS REVIEW, AND FIRE

DEPARTMENT INSPECTORS.

5. OBTAIN AND PAY FOR PERMITS REQUIRED FOR INSTALLATION OF FIRE ALARM SYSTEM. PROVIDE SHOP DRAWING SUBMITTAL DOCUMENTS TO AUTHORITY HAVING JURISDICTION TO OBTAIN PERMIT. SUBMITTAL SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING:

A. SCALED FLOOR PLANS WITH ROOM NAMES AND NUMBERS WHICH INDICATE USE OF ALL ROOMS.

B. FIRE ALARM DEVICE AND CABLE SYMBOL LEGEND.

C. FLOOR PLAN LAYOUT SHOWING LOCATIONS OF ALL DEVICES AND CONTROL EQUIPMENT, INCLUDING MOUNTING HEIGHTS OF ALARM INITIATING DEVICES AND

NOTIFICATION DEVICES.

D. FIRE ALARM CONTROL PANEL AND ANNUNCIATOR LOCATION.

E. POWER CONNECTION.

F. BATTERY CALCULATIONS.

G. VOLTAGE DROP CALCULATIONS FOR NOTIFICATION APPLIANCE CIRCUITS.

H. SIZE, TYPE, AND NUMBER OF CONDUCTORS.

I. MANUFACTURER'S TECHNICAL DATA SHEETS INCLUDING MODEL NUMBERS AND LISTING INFORMATION FOR EQUIPMENT, DEVICES, AND MATERIALS.

J. DETAILS OF CEILING HEIGHT AND CONSTRUCTION.

K. INTERFACE OF FIRE SAFETY CONTROL FUNCTIONS.

L. FIRE ALARM SYSTEM RISER.

M. SEQUENCE OF OPERATIONS INPUT/OUTPUT MATRIX.

N. DEVICE TO DEVICE WIRING.

O. LOUDNESS AND CANDELA SETTINGS FOR EVERY NOTIFICATION APPLIANCE.

6. FIRE ALARM BRANCH CIRCUIT IDENTIFICATION MUST COMPLY WITH NFPA 70 AND NFPA 72:

· PROVIDE APPROVED RED CIRCUIT BREAKER LOCKOUT DEVICE FOR EACH CIRCUIT BREAKER SERVING A FIRE ALARM CIRCUIT.

· IDENTIFY EACH FIRE ALARM CIRCUIT WITH A RED PHENOLIC NAMEPLATE WITH WHITE LETTERING. NAMEPLATE SHALL READ "FIRE ALARM CIRCUIT". FASTEN

NAMEPLATE IN PANELBOARD ADJACENT TO CIRCUIT BREAKER.

7. IDENTIFY POWER SOURCE AND LOCATION OF BRANCH CIRCUIT DISCONNECT SERVING FIRE ALARM EQUIPMENT. FASTEN PHENOLIC NAMEPLATE TO FIRE ALARM SYSTEM

PANEL(S) INDICATING LOCATION OF DEDICATED BRANCH CIRCUIT DISCONNECTING MEANS. NAMEPLATE SHALL READ "THIS PANEL FED FROM PANEL ____, CIRCUIT NO.

____, LOCATED IN _____."

8. IDENTIFY EACH FIRE ALARM DEVICE AND EQUIPMENT ENCLOSURE. DEVICE LABELS SHALL INDICATE ADDRESS AND ZONE.

9. IDENTIFY FIRE ALARM CIRCUITS AT TERMINAL AND JUNCTION LOCATIONS WITH PERMANENT LABELS. PAINT FIRE ALARM CIRCUIT JUNCTION BOX COVERS RED AND LABEL

COVER "FIRE ALARM". PAINT CONDUITS CARRYING FIRE ALARM SYSTEM CIRCUITS RED.

FIRE ALARM SYSTEM ROOM TEMPERATURE SWITCH - -FRZ

NOT FOR BID

DIN

G

OR C

ONSTRUCTIO

N

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

A2112

Q

AC

H

IST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

06.05.26

PROGRESS SET

NOT FOR CONSTRUCTION

FA002

FIR

E A

LA

RM

C O

VE

R

SH

EE

T

FA002

FIRE ALARM DEVICE MOUNTING DETAIL

NOT TO SCALE

SIDE WALL

SIDE WALLSIDE WALL

ANNUNCIATOR PANEL OR

LISTED CEILING MOUNTED

NOTIFICATION APPLIANCE

FINISHED FLOOR

CEILING

AUDIBLE/STROBE COMBINATION

1'-0" MAX.1'-0" MAX

6'-6" MAX

5'-0" MIN TO

OF DEVICE

OR

0'-6" BELOW

FINISHED CEILING,

WHICHEVER IS

LOWER

7'-6" TO TOP

FROM STROBE

LENS TO FLOOR

OR

WITHIN 0'-6" OF

FINISHED CEILING,

WHICHEVER IS

LOWER

6'-8" MIN TO 8'-0" MAX

OPERATING HANDLE TO FLOOR

3'-10"� FROM

5'-0" MAX

3'-0" MIN0'-4" MIN

0'-4" MIN.

0'-4" MIN.

EXIT

SMOKE OR HEAT

DETECTOR

DO NOT LOCATE

HEAT DETECTOR

WITHIN THIS AREA

HEAT DETECTOR MOUNTING

PLACEMENT REQUIREMENTS

HEAT DETECTOR

HEAT

DETECTOR

FROM EXIT OPENING

MOUNT FIRE ALARM DEVICES ON APPROVED BOXES.NOTE:

REMOTE LAMP

W/ TEST SWITCH

HEAT

DETECTOR

MOUNT DETECTOR

ON APPROVED BOX 6'-0" MAX LENGTH FLEXIBLE RACEWAY TO DEVICE

MOUNTED ON SUSPENDED CEILING

FLOOR-CEILING ASSEMBLY

CEILING

AUDIBLE

DEVICE

SMOKE

DETECTOR

FINISHED FLOOR

MANUAL

PULL STATION

STROBE

FIRE ALARM CONTROL

PANEL OR EMERGENCY

VOICE PANEL

TERMINAL CABINET

JUNCTION BOX

CONDUIT

AIR SUPPLY DIFFUSER OR

RETURN AIR OPENING

INSTALL PER NATIONAL

ELECTRICAL CODE

BVT

FA002

ELEVATOR FIRE ALARM AND SPRINKLER WORK SUMMARY

NOT TO SCALE

NOT FOR BID

DIN

G

OR C

ELEVATOR 1

STAIR 1

FIRE

DEPARTMENT

CONNECTION

FACP

STAIR 2

EXIT EXIT EXIT

ELEVATOR 1 ELEVATOR

MACHINE ROOM

STAIR 1

STAIR 2

ELEVATOR 1

STAIR 1

STAIR 3

EXIT

ATTIC ACCESS

ATTIC ACCESS

Torchio Architects, Inc.

COPYRIGHT C

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

A2112

Q

AC

H

IST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

06.05.26

PROGRESS SET

NOT FOR CONSTRUCTION

FA003

FIR

E A

LA

RM

G

RA

PH

IC

M

AP

LA

YO

UT

FA003

FIRE ALARM GRAPHIC MAP LAYOUT

1/16" = 1'-0"

BVT

0 8 32 48 FT16

1/16" = 1' - 0"

GROUND LEVEL

LOWER LEVEL

UPPER LEVEL

ATTIC

NOT FOR BID

DIN

G

OR C

ONSTRUCTIO

N

AutoCAD SHX Text + 6"6"

COURTROOM

OFFICE 10

OFFICE 9

OFFICE 8

OFFICE 11

OFFICE 13

OFFICE 12

LOBBY

VAULTELEV.

F

FAAP

F

F

S

CRAWL SPACE

CRAWL SPACE

CRAWL SPACE

BASEMENT

MECHANICAL

MECHANICAL

KITCHEN

CELL 1

CELL 2

OFFICE

LAV.

SECURITY/SURVEILLANCE

OFFICE

OFFICE

OFFICE

OFFICE

OLD LAW LIBRARY

SAFE

IT

BACK-UP 911 CENTER

OFFICE

OFFICE OFFICE

OFFICE

WOMEN

MEN

ELEV.

OFFICE

FA

IP

F

F

S

S

CRAWL SPACE

CRAWL SPACE

COURTROOM

JURY CONFERENCE

OFFICE

JUDGE'S CHAMBER

HOLDING CELL

ELEV.

F

S

F

Torchio Architects, Inc.

COPYRIGHT C

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

A2112

Q

AC

H

IST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

06.05.26

PROGRESS SET

NOT FOR CONSTRUCTION

FAD100

GROUND LEVEL - FIRE ALARM - DEMOLITION PLAN

1/8" = 1'-0"

0 4 16 24 FT8

1/8" = 1' - 0"N FAD100

FIR

E A

LA

RM

DE

M O

LIT

IO

N

FAD100

LOWER LEVEL - FIRE ALARM - DEMOLITION PLAN

1/8" = 1'-0" N

FAD100

UPPER LEVEL - FIRE ALARM - DEMOLITION PLAN

1/8" = 1'-0" N

SPECIAL NOTES: (APPLICABLE TO THIS SHEET ONLY)

--1

DRAWING NOTES: (APPLICABLE TO THIS SHEET ONLY)

1. UNLESS OTHERWISE NOTED, FIRE ALARM ITEMS SHOWN BY DASHED HEAVY

LINEWEIGHT ( ) INDICATE EXISTING ITEMS TO BE REMOVED. FIRE ALARM

ITEMS SHOWN BY SOLID LIGHT LINEWEIGHT ( ) INDICATE EXISTING ITEMS

TO REMAIN.

2. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING

CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR

GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING

CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE

FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO FABRICATION

OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE DISCOVERED

THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE CONTRACTOR

SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING AND AWAIT WRITTEN

DIRECTION BEFORE PROCEEDING WITH THE WORK.

ZAJ

NOT FOR BID

DIN

G

OR C

ONSTRUCTIO

N

AutoCAD SHX Text 30 x x 68

AutoCAD SHX Text 30 x x 68

AutoCAD SHX Text 30 x x 68

30 x x 68

S E

F F

WP

FADC FACP

F F

ARAP

FA

AP

DH

DH

FIRE DEPARTMENT

CONNECTION30

REGISTER OF WILLS

BREAK AREA

STAIRS

ELEV. LOBBY

LOBBY

ORPHAN'S COURTROOM

RECEPTION

109RECORDS

CORRIDOR

R.O.W. OFFICE

CHIEF DEPUTY

DEPUTY

ELEV

UNISEX

UNISEX

OFFICE OF THE

CLO.

109A

FSTS

AE TEAM TO COORDINATE

LOCATION OF FACP ON LOWER

LEVEL WITH DPWS

E

S E

AM

AM

60 15

F

30 30

AR

AMAMAM

F

MECHANICAL

MEN'S

WOMEN'S

J.C.

ELEV.

BSMT. / MECH.

ROOM

CORRIDOR

SECONDARY PSAP

I.T.

20A

MEETING ROOM

OPEN OFFICE AREA

ELECTRICAL

SPRINKLER

VAULT

22A

OPEN OFFICE AREA

OFFICE

OFFICE

BREAK

I.T.

UT

ILI

TY

TU

NN

EL

A

MECHANICAL/STORAGE

MACHINE

STAIRS

CRAWL SPACE

CLO.

LOWER LOBBY

CRAWL

CRAWL SPACE

SPACE

CRAWL SPACE

MECH. CL.

30A

F

TS

TS FS TS TS

TS

AM

TS

Torchio Architects, Inc.

COPYRIGHT C

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

A2112

Q

AC

H

IST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

06.05.26

PROGRESS SET

NOT FOR CONSTRUCTION

FA100

GROUND LEVEL - LIGHTING - NEW WORK

1/8" = 1'-0"

0 4 16 24 FT8

1/8" = 1' - 0"

N

FA100

FIR

E A

LA

RM

NE

W W

O

RK

FA100

LOWER LEVEL - FIRE ALARM - NEW WORK

1/8" = 1'-0" N

SPECIAL NOTES: (APPLICABLE TO THIS SHEET ONLY)

CONTROL RELAY MODULE FOR ELEVATOR CONTROLLER INTERFACE TO

INITIATE RECALL TO DESIGNATED LEVEL.

DRAWING NOTES: (APPLICABLE TO THIS SHEET ONLY)

1. UNLESS OTHERWISE NOTED, FIRE ALARM ITEMS SHOWN BY SOLID HEAVY

LINEWEIGHT ( ) INDICATE NEW WORK TO BE PROVIDED. FIRE ALARM ITEMS

SHOWN BY SOLID LIGHT LINEWEIGHT ( ) INDICATE EXISTING ITEMS TO

REMAIN.

2. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING CONDITIONS

HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR GENERAL FIELD

OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING CONDITIONS IN

DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING

THE ACTUAL EXISTING CONDITIONS PRIOR TO FABRICATION OR PERFORMANCE

OF ANY WORK. SHOULD CONDITIONS BE DISCOVERED THAT PREVENT

EXECUTION OF THE WORK AS INDICATED, THE CONTRACTOR SHALL

IMMEDIATELY NOTIFY THE ENGINEER IN WRITING AND AWAIT WRITTEN

DIRECTION BEFORE PROCEEDING WITH THE WORK.

CONTROL RELAY MODULE FOR ELEVATOR CONTROLLER INTERFACE TO

INITIATE RECALL TO ALTERNATE LEVEL.

CONTROL RELAY MODULE FOR ELEVATOR CONTROLLER INTERFACE TO

ACTIVATE CAR WARNING SIGNAL.

BVT

COORDINATE EXACT LOCATION OF FIRE ALARM DEVICES IN THIS ROOM WITH

ELEVATOR CONTRACTOR.

FOR MONITORING SHUNT TRIP CONTROL VOLTAGE.6

FOR ACTIVATING SHUNT TRIP.7

PROVIDE A HEAT DETECTOR ADJACENT TO EACH SPRINKLER. MAKE

CONNECTION THROUGH FIRE ALARM CONTROL PANEL TO ELEVATOR SHUNT

TRIP DEVICE.

FOR SPRINKLER FLOW NOTIFICATION. COORDINATE FINAL LOCATION WITH

AHJ.

NOT FOR BID

DIN

G

OR C

S E

F

AR

UPPER LOBBY

COURTROOM

CONFERENCE

200A

ELEV. LOBBY

206STAIRS

JUDGE'S CHAMBER

REST LOBBY

UNISEX

UNISEX

ELEV

TOILET

205A

CLOSET

205B

F

FRZ FRZ

FRZ FRZ

FRZ FRZ

FRZ

FRZ

FSTS

Torchio Architects, Inc.

COPYRIGHT C

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

A2112

Q

AC

H

IST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

06.05.26

PROGRESS SET

NOT FOR CONSTRUCTION

0 4 16 24 FT8

1/8" = 1' - 0"

FA101

FIR

E A

LA

RM

NE

W W

O

RK

SPECIAL NOTES: (APPLICABLE TO THIS SHEET ONLY)

--------------------------1

DRAWING NOTES: (APPLICABLE TO THIS SHEET ONLY)

1. UNLESS OTHERWISE NOTED, FIRE ALARM ITEMS SHOWN BY SOLID HEAVY

LINEWEIGHT ( ) INDICATE NEW WORK TO BE PROVIDED. FIRE ALARM ITEMS

SHOWN BY SOLID LIGHT LINEWEIGHT ( ) INDICATE EXISTING ITEMS TO

REMAIN.

2. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING CONDITIONS

HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR GENERAL FIELD

OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING CONDITIONS IN

DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING

THE ACTUAL EXISTING CONDITIONS PRIOR TO FABRICATION OR PERFORMANCE

OF ANY WORK. SHOULD CONDITIONS BE DISCOVERED THAT PREVENT

EXECUTION OF THE WORK AS INDICATED, THE CONTRACTOR SHALL

IMMEDIATELY NOTIFY THE ENGINEER IN WRITING AND AWAIT WRITTEN

DIRECTION BEFORE PROCEEDING WITH THE WORK.

BVT

FA101

ATTIC - FIRE ALARM - NEW WORK

1/8" = 1'-0" N

FA101

UPPER LEVEL - FIRE ALARM - NEW WORK

1/8" = 1'-0" N

NOT FOR BID

DIN

G

OR C

ONSTRUCTIO

N

+ 6"6"

Project Number:

Date:

Revisions:

Drawn By:

Sheet:

A2112

Q

AC

H

IST

O

RIC

C O

UR

TH

O

US

E R

EN

O

VA

TIO

N

0 C

O

UR

TH

O

US

E S

Q

UA

RE

CE

NT

RE

VI

LL

E, M

AR

YL

AN

D

06.05.26

PROGRESS SET

NOT FOR CONSTRUCTION

FA300

FIR

E A

LA

RM

M

AT

RIX

FIRE ALARM SYSTEM AC POWER FAILURE

FIRE ALARM SYSTEM LOW BATTERY

FIRE ALARM SYSTEM OPEN CIRCUIT

FIRE ALARM SYSTEM GROUND FAULT

FIRE ALARM SYSTEM NOTIFICATION

APPLIANCE SHORT CIRCUIT

HVAC DUCT SMOKE DETECTOR

SMOKE DETECTOR AT SMOKE DAMPER

SMOKE DETECTOR AT FIRE-SMOKE DAMPER

CLOSE ASSOCIATED SMOKE DAMPER

A B C D E F G H I K L M N O P Q R V W X Y Z AAS T U

SYSTEM INPUTS

SYSTEM OUTPUTS

SUPPLEMENTARY

BB

ILL

UMINATE PROPER LE

D AT GRAPHIC ANNUNCIATOR

POST INDICATOR VALVE TAMPER SWITCH

J

CC DD

RELEASE MAGNETICALLY

HELD SMOKE DOORS

RECALL

ELEVATOR TO ALTERNATE LE

VEL

RECALL

ELEVATOR TO DESIGNATED LE

VEL

ACTUATE ASSOCIATED FAN SHUT DOWN SIGNAL

EMERGENCY CONTROL FUNCTION

SHUT DOWN POWER TO ELEVATOR

SHUT DOWN RESPECTIVE AIR HANDLIN

G UNIT

ACTUATE WARNING TO ELEVATOR CAB

CLOSE ASSOCIATED FIRE/SMOKE DAMPER

ELEVATOR LOBBY SMOKE DETECTOR

DESIGNATED LEVEL ELEVATOR LOBBY

SMOKE DETECTOR

ELEVATOR MACHINE ROOM SMOKE

DETECTOR

ELEVATOR MACHINE ROOM HEAT

DETECTOR

ELEVATOR SHUNT TRIP CONTROL POWER

SUPERVISING RELAY

SPRINKLER SYSTEM WATER FLOW SWITCH IN

ELEVATOR PIT

ACTUATE COMMON SUPERVISORY SIGNAL IN

DICATOR

ACTUATE AUDIBLE SUPERVISORY SIGNAL

ACTUATE COMMON ALARM SIGNAL IN

DICATOR

ACTUATE COMMON TROUBLE SIGNAL IN

DICATOR

ACTUATE AUDIBLE ALARM SIGNAL

ACTUATE AUDIBLE COMMON TROUBLE SIGNAL

ACTUATE ASSOCIATED FLOOR ALARM INDICATOR

CONTROL UNIT ANNUNCIATION

GENERATOR STATUS RUNNING

RECORD INFORMATION ON CPU

DISPLAY DEVICE ADDRESS AT CONTROL U

NIT

ACTUATE DISTINCT VISIBLE ELEVATOR RECALL

ALARM

MANUAL FIRE ALARM BOX

AREA SMOKE OR HEAT DETECTOR

ACTUATE LO

CAL V

ISUAL A

ND TEMPORAL 4

AUDIBLE SIGNAL

TRANSMIT FIRE ALARM SIGNAL T

O SUPERVISING STATION

TRANSMIT SUPERVISORY SIGNAL T

O SUPERVISING STATION

TRANSMIT TROUBLE SIGNAL T

O SUPERVISING STATION

NOTIFICATION

ACTUATE EXTERIOR AUDIBLE/VISUAL S

IGNAL

ACTUATE AUDIBLE AND VISUAL E

VACUATION SIGNALS

CARBON MONOXIDE DETECTOR

SPRINKLER WATER FLOW SWITCH

SPRINKLER OR STANDPIPE VALVE TAMPER

A B C D E F G H I K L M N O P Q R V W X Y Z AAS T U BBJ CC DD

ROOM TEMPERATURE SENSORS AT OR

BELOW 40 DEGREES F

FA-201

FIRE ALARM MATRIX

NTS

FA-201

ELEVATOR FIRE ALARM MATRIX

NTS

BVT

NOT FOR BID

DIN

G

OR C