drawing - CIVIL_QAC Historic Courthouse RFQ_2026.07.01.pdf
PDF 10 MB Posted
- Attached to
- Historic Courthouse Renovation
- Solicitation number
- BPM057809
- Issued by
- Queen Anne's County, Maryland
About this file
This document comprises civil engineering site and construction plans for the Historic Courthouse renovation project in Centreville, Maryland, prepared by Select Engineering on behalf of Queen Anne's County Department of Public Works and the Commissioners of Queen Anne's County. The project involves comprehensive renovation of the 233-year-old institutional building located at 100 Courthouse Square, with work anticipated to involve minimal changes to site layout and a net reduction in impervious area of 302 square feet. The renovation scope includes demolition of existing systems dating to the 1960s Civil Defense era modifications, installation of new HVAC systems with multiple VRF and mini-split units, complete replacement of plumbing and electrical systems, addition of a sprinkler system with new water service, installation of a backup power generator, new telecom and security systems, asbestos abatement, and architectural improvements to support courtroom, Register of Wills office, and basement 911 call center and support spaces. The existing building encompasses 16,006 square feet of floor area across basement, first, and second floors, with no change in building footprint proposed.
The construction drawings detail sediment and erosion control requirements, utility coordination including new fiber optic infrastructure installation by Skyline Technology Solutions, stormwater management waiver approval dated January 7, 2025, and a comprehensive construction sequence spanning multiple months. The contractor is required to notify Queen Anne's County Department of Public Works and the Town of Centreville two weeks prior to construction commencement to schedule a pre-construction meeting, verify and supplement utility markings, and install stabilized construction entrance and tree protection measures within four days. Base bid alternates include a deduct alternate to remove basement roof waterproofing and perimeter foundation drains, with excavated materials requiring disposal at approved offsite locations or optional stockpiling at the Vincit Street property. The property is designated Tax Map 44C, Grid 8, Parcel 935, zoned Central Business District with zero setbacks on front and side, located on public water and sewer systems, and outside floodplain and Chesapeake Bay critical area designations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TITLE SHEET
EXISTING CONDITIONS PLAN
DEMOLITION PLAN
DEMOLITION DETAILS
SITE AND DRAINAGE PLAN
SITE DETAILS
SEDIMENT & EROSION CONTROL PLAN
SEC DETAILS
UTILITY PLAN AND DETAILS
SKYLINE FIBER OPTIC DETAILS
PLAN
DEVELOPER
QUEEN ANNE'S COUNTY
DEPARTMENT OF PUBLIC WORKS
312 SAFETY DR
CENTREVILLE, MD 21617
PHONE: (410) 758-0925
OWNER
COMMISSIONERS OF
QUEEN ANNE'S COUNTY
107 N LIBERTY ST
CENTREVILLE, MD 21617
(410) 758-4098
PREMISE ADDRESS
100 COURTHOUSE SQUARE
CENTREVILLE, MD 21617
SITE NOTES
1. PROPERTY SHOWN HEREON IS DESIGNATED AS TAX MAP 44C,GRID 8, PARCEL 935.
2. DEED REFERENCE: BPW 132/643
3. THIS SITE IS ZONED CBD - CENTRAL BUSINESS DISTRICT
3.1. FRONT SETBACK = 0 FEET
3.2. SIDE SETBACK = 0 FEET
3.3. REAR SETBACK = 5 FEET (NOT APPLICABLE)
4. EXISTING USE: INSTITUTIONAL
5. PROPOSED USE: INSTITUTIONAL
6. PROPERTY LINES SHOWN HEREON ARE BASED ON FIELD SURVEYS AS PERFORMED BY
McCRONE ON DECEMBER4, 2023 AND JANUARY 2, 2024.
7. TOPOGRAPHY AND SPOT GRADES SHOWN HEREON WAS OBTAINED FROM THE
AFOREMENTIONED SURVEYS ARE ON NAD 1983 AND NAVD 1988.
8. THE PROPERTY IS SERVED BY THE PUBLIC WATER AND SEWER.
9. SOILS WITHIN THE LIMIT OF DISTURBANCE CONSIST ENTIRELY OF INGLESIDE SANDY LOAM
(IgA), HYDROLOGIC SOIL GROUP A, K FACTOR 0.15, AS PER THE USDA-NRCS WEB SOIL
SURVEY AS OF OCTOBER 2023.
10. THE PROPERTY IS NOT LOCATED WITHIN THE ONE PERCENT CHANCE FLOOD PLAIN
ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY'S F.I.R.M. MAP FOR
QUEEN ANNE'S COUNTY, PANEL NO. 24035C0212D, DATED: 11/05/2014.
11. THE PROPERTY IS NOT LOCATED WITHIN THE CHESAPEAKE BAY CRITICAL AREA.
12. THERE APPEAR TO BE NO NON-TIDAL WETLANDS ON THE PROPERTY.
13. THERE ARE NO STEEP SLOPES ON THE PROPERTY.
14. NO FOREST IS PROPOSED TO BE DISTURBED AS PART OF THE PROPOSED DEVELOPMENT.
15. THE PROPERTY IS NOT LOCATED WITHIN A SENSITIVE SPECIES PROJECT REVIEW AREA
ACCORDING TO THE QUEEN ANNE'S COUNTY PROPERTY VIEWER AS OF OCTOBER 2025.
16. THE PROJECT DOES NOT REQUIRE SITE PLAN APPROVAL BY THE TOWN OF CENTREVILLE
PLANNING COMMISSION BECAUSE THERE IS NO CHANGE IN BUILDING AREA. AS A RESULT,
THE PROJECT IS NOT CONSIDERED TO BE A "DEVELOPMENT".
1. THE EXISTING UTILITIES SHOWN IN THESE DRAWINGS IS BASED ON BEST AVAILABLE INFORMATION. NO
GUARANTEE TO THE ACCURACY OF THE LOCATION (HORIZONTAL OR VERTICAL) IS MADE BY THE
ENGINEER. CONTRACTOR TO FIELD VERIFY AND TEST PIT AS NEEDED TO VERIFY THE LOCATION OF THE
EXISTING UTILITIES. THIS SHALL BE DONE AS PART OF THE CONTRACT FOR THE WORK SHOWN IN THESE
DRAWINGS. ANY DAMAGE INCURRED TO SUCH UTILITIES SHALL BE REPAIRED IMMEDIATELY AT THE
CONTRACTOR'S EXPENSE.
2. THE CONTRACTOR SHALL NOTIFY THE FOLLOWING TWO (2) WEEKS PRIOR TO THE START OF
CONSTRUCTION TO SCHEDULE A PRE-CONSTRUCTION MEETING:
3. ALL CONSTRUCTION WITHIN PUBLIC AND PRIVATE ROADS SHALL BE MARKED FOR TRAFFIC AND
PEDESTRIAN SAFETY. ALL SIGNS SHALL BE PLACED IN ACCORDANCE WITH SECTION VI OF THE MANUAL
ON UNIFORM TRAFFIC CONTROL DEVICES.
4. ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE TOWN OF
CENTREVILLE DEPARTMENT OF PUBLIC WORKS.
5. THE CONTRACTOR ASSUMES ALL RESPONSIBILITIES FOR ANY DEVIATIONS FROM THESE PLANS, UNLESS
SAID DEVIATION IS APPROVED BY THE ENGINEER. THE CONTRACTOR SHALL RECEIVE WRITTEN
PERMISSION FROM THE ENGINEER IF A DEVIATION OF THE PLAN IS NECESSARY.
6. ALL DISTURBED AREAS SHALL BE SMOOTHLY GRADED TO PROVIDE POSITIVE DRAINAGE IN THE DIRECTION
OF FLOW ARROWS, SPOT GRADES, AND CONTOURS SHOWN HEREON AND STABILIZED WITH TOPSOIL, SEED, AND MULCH. IF SETTLEMENT OCCURS, TOPSOIL, SEEDING AND MULCHING SHALL BE REPEATED
UNTIL SETTLEMENT SUBSIDES (SEE EROSION AND SEDIMENT CONTROL SPECIFICATIONS).
7. ALL TRASH, TREES, DEMOLITION DEBRIS, AND UNDERBRUSH ARE TO BE CLEARED AND REMOVED OFF
SITE TO AN APPROVED DUMP SITE BY THE CONTRACTOR.
8. ANY EXCESS EXCAVATED MATERIAL PLACED OUTSIDE OF THOSE AREAS DESIGNATED ON THIS PLAN
SHALL MEET APPROVAL OF THE TOWN AND QUEEN ANNE'S COUNTY INSPECTORS AND ENGINEER.
9. ANY EXISTING SURVEY MONUMENTATION THAT IS DISTURBED DURING CONSTRUCTION SHALL BE
REPLACED BY A REGISTERED SURVEYOR AT THE CONTRACTOR'S EXPENSE.
10. ALL FILL AREAS WITHIN LIMITS OF PAVEMENT, BUILDING CONSTRUCTION, AND OTHER AREAS AS
DESIGNATED ON THESE PLANS SHALL BE COMPACTED TO 95% MODIFIED PROCTOR DENSITY AND LAID
AND COMPACTED IN 8" MAXIMUM LIFTS.
11. ALL FILL AREAS WITHIN LIMITS OF WALKS, PATIOS, ETC. SHALL BE COMPACTED TO 90% MODIFIED
PROCTOR DENSITY AND LAID AND COMPACTED IN 8" MAXIMUM LIFTS.
12. IF POSSIBLE, EXCAVATIONS AND TRENCHES SHALL NOT REMAIN OPEN OVERNIGHT. IF IT IS NECESSARY
FOR TRENCHES TO REMAIN OPEN, STEEL PLATES, CAPABLE OF BEARING TRAFFIC, SHALL BE USED TO
COMPLETELY COVER THE TRENCH OR SAFETY FENCING SHALL BE INSTALLED TO COMPLETELY ENCLOSE
THE EXCAVATION OR TRENCH. THIS NOTE DOES NOT APPLY TO THE EXCAVATION TO UNCOVER THE
BASEMENT ROOF.
13. THE CONTRACTOR SHALL PROVIDE THE QUEEN ANNE'S COUNTY SWM INSPECTOR AND THE TOWN OF
CENTREVILLE WITH A SET OF RED-LINED AS-BUILTS OF THE PROPOSED STORMWATER FACILITIES. RED
LINES SHALL SHOW THE HORIZONTAL AND VERTICAL LOCATION OF ALL UNDERGROUND PIPING AND
STRUCTURES AS SURVEYED, BEFORE BEING BACKFILLED.
GENERAL NOTES
INDEX OF DRAWINGS
DESCRIPTIONSHEET #
C1.0
C1.1
C1.2
C1.3
C2.1
C2.2
C3.1
C3.2
C4.1
C4.2
VICINITY MAP
SCALE: 1" = 1000'
T
O
C
H
E
S
T
E
R
T
O
W
N
ARCHITECT
TORCHIO ARCHITECTS, INC
205 EAST WATER ST, SUITE A
CENTREVILLE, MD 21617
PHONE: (401) 758-1000
TOTAL SITE AREA =
EXISTING IMPERVIOUS AREA (46.7%) =
IMPERVIOUS AREA TO BE REMOVED =
IMPERVIOUS AREA TO BE ADDED =
RESULTING IMPERVIOUS AREA (45.9%) =
EXISTING BASEMENT FLOOR AREA = 8,058
EXISTING FIRST FLOOR AREA = 3,274
EXISTING SECOND FLOOR AREA = 3,274
TOTAL EXISTING FLOOR AREA = 16,006
FLOOR AREA TO BE REMOVED = 0
FLOOR AREA TO BE ADDED = 0
RESULTING FLOOR AREA = 16,006
SITE STATISTICS
MD DEPARTMENT OF THE ENVIRONMENT INSPECTOR 410-901-4020
TOWN OF CENTREVILLE DEPT. OF PUBLIC WORKS 410-758-1180
QUEEN ANNE'S COUNTY DEPT. OF PUBLIC WORKS 410-758-0925
DELMARVA POWER 410-758-0830
MISS UTILITY 800-441-8355
SELECT ENGINEERING 410-758-2237
QAC HISTORIC COURTHOUSE
SITE, SEC, AND UTILITY PLANS
SITE AND CONSTRUCTION PLANS
R
D
R
D
U
S
SITE
Renovation of the historic Queen County Courthouse is anticipated to involve little to no change in site layout, and we estimate a net reduction in impervious area of 302 sqft. Pursuant to section 14:4-9 B. (3) and 14:4-9 C. (3) of the Queen Anne's county code, the design team hereby requests a waiver from the requirement to provide stormwater quantity management and stormwater quality management. It is not feasible to provide stormwater practices onsite for the following reasons:
1. There is a lack of available pervious space on the property that is not encumbered by mature trees.
2. The only location onsite that has the potential for a stormwater outfall is along North Liberty Street. The building (including underground basement) and perimeter sidewalks occupy almost the entirety of the north portion of the lot, such that no stormwater practices can be placed in proximity to the outfall locations.
3. It is not advisable to provide onsite ESD practices that rely on infiltration because of the existence of the basement. The Maryland Stormwater Manual specifically indicates that practices that rely in infiltration should not be located close to buildings were basement seepage may occur.
4. The historic nature of the 233-year-old building and site makes it important to avoid removing trees or adding features that detract from the aesthetic value of the site.
Refer to waiver letter approved by Lee Edgar, P.E. dated January 7, 2025.
STORMWATER MANAGEMENT WAIVER
RENOVATION PROJECT
SURVEYOR
McCRONE
320 PENNSYLVANIA AVE
CENTREVILLE, MD 21617
PHONE: (410) 758-2237
ENGINEER
SELECT ENGINEERING
PO BOX 103
CENTREVILLE, MD 21617
PHONE: (301) 529-2368
31184
1/16/2027
P L O
T T
E D
J u l p m
A P
P R
O V
E
B
Y
D A
T E
S O
I L
N
S E
R V
A T
I O
N
S
E R
V I C
E Q
A
C o
A P
P R
O V
D A
T E
D E
P T
O
F
P
U B
L
W
R
K S
Q A o
D M y
D o c u m e n t s D u m b
H o m e P r o j e c t s
T o r c h i o
C o u r t h o u s e C
A D
C o u r t h o u s e E
N G
B a s e d w g T a b
T
I
PO Box 103
Centreville, MD 21617
301-529-2368 e c t
Engineering
D
R
A
F
T
MAP 44C
PARCEL
DEED
REFERENCE
USE
936 NOT LISTED
824 3 S ASSOCIATES L L C 1822/ 530
833 132/ 643
834 FARMERS NATIONAL BANK OF MD 117/ 24 VACANT
835 APG REAL PROPERTIES LLC 2273/ 329 COMMERCIAL
836 SMITH REBECCA S & RICHARD A J/T 1229/ 287 COMMERCIAL
TABLE OF ADJACENT PROPERTIES
STARTING WITH THE LIBERTY BUILDING, PROCEEDING CLOCKWISE
ALL LISTINGS ARE NOW OR FORMERLY (N/F)
OWNER NAME
COUNTY COMMISSIONERS OF
QUEEN ANNE'S CO
837 HIBERNIA ROAD LLC 774/ 6 COMMERCIAL
838 117/ 20 COMMERCIAL
773 01952/ 00424
768 ESLAWYER LLC 2152/ 106 COMMERCIAL
767 THOMPSON BUILDING LLC 1498/ 464 COMMERCIAL
767-TRACT 2 CLAIBORNE FARM INC 1033/ 430 COMMERCIAL
754 CALLAHANS APPLIANCES INC 2/ 454 COMMERCIAL
766 653/ 103
917 CENTREVILLE TOWN NOT LISTED
918 MONTE VISTA INVESTMENTS LLC 2461/ 439 COMMERCIAL
919 GRIFFIN DAVID R 2902/ 146 COMMERCIAL
920 WEST THOMAS GIFFORD 2214/ 390 COMMERCIAL
921 HARPER JOHN F III ROTH KAREN L 484/ 00524 COMMERCIAL
922 WESTON GROUP LLC 1050/ 545 COMMERCIAL
925 540/ 8916 COMMERCIAL
923 WESTON GROUP LLC 0.6 COMMERCIAL
916 SHORE UNITED BANK 4/ 379 MAIN BANK
DEPARTMENT OF EMERGENCY
SERVICES OFFICE OF THE FIRE
MARSHAL CERTIFICATE
THIS IS TO CERTIFY THAT THIS SITE PLAN WAS APPROVED BY THE QUEEN
ANNE'S COUNTY DEPARTMENT OF EMERGENCY SERVICES - OFFICE OF
THE FIRE MARSHAL ON THE DAY OF , 20 .
JEFFREY MORGAN, FIRE MARSHAL .
BID ALTERNATES
1. DEDUCT ALTERNATE TO REMOVE WATERPROOFING THE BASEMENT ROOF EXCEPT
AS INDICATED ON WATERPROOFING DWG BE1.2 AND REMOVING THE PERIMETER
FOUNDATION DRAINS FROM THE SCOPE OF WORK.
SHEET C1.2 EXISTING STONE MONUMENT AND BENCHES, AS WELL AS THE
MAJORITY OF BRICK WALK ALONG LIBERTY STREET CAN REMAIN UNDISTURBED.
SAWCUT BRICK WALK TO CONNECT ROOF DRAINS TO EXISTING DRAINAGE INLETS
AND REPAIR BRICK SIDEWALK IN KIND .
SHEET C3.1 REDUCE LIMIT OF EXCAVATION TO ONLY WHAT IS NECESSARY TO
INSTALL THE PROPOSED ROOF DRAINS AND INSTALL WATERPROOFING INDICATED
ON WATERPROOFING DWG BE1.2 . REFER TO SHEET C3.1 AND KEY NOTE 1 TO
STOCKPILE EXCAVATED SOILS ONSITE WITH THE ADDITION OF FILTER LOG
PERIMETER CONTROLS.
STATE OF MD TO THE BOARD OF
PUBLIC WORKS
BRANCH BANKING & TRUST
COMPANY
COUNTY COMMISSIONERS OF
QUEEN ANNE'S COUNTY THE
CALLAHAN MARGARET
CALLAHAN MARK
EXEMPT
COMMERCIAL
EXEMPT
COMMERCIAL
EXEMPT
COMMERCIAL
DRUMMOND CHRISTOPHER F
DRUMMOND CINDY LEE
906 TOWN COUNCIL OF CENTREVILLE 2584/ 260 COMMERCIAL
924 117 LAWYERS ROW L L C 1819/ 13 COMMERCIAL
COMMERCIAL
COMMERCIAL
EXEMPT
COMMERCIAL
EXISTING SITE PLAN
SCALE: 1"= 20'
ENLARGED VIEW OF EXISTING BUILDING
SCALE: 1"=10'
31184
1/16/2027
P L O
T T
E l p m
A P
P R
O V
D A
T E
S O
I L
C
O N
S E
R V
A T
I O
N
S
E R
V I C
E Q
A
C o
A P
P R
O V
D A
T E
D E
P T
O
F
P
U B
L
R
K S
D M y
D o c u m e n t s D u m b
H o m e P r o j e c t s
T o r c h i o
C o u r t h o u s e
C
A D
C o u r t h o u s e E
N G
B a s e d w g T a b
E
X
PO Box 103
Centreville, MD 21617
301-529-2368 e c t
Engineering
EX. WELL TO BE CAPPED BY OTHERS PRIOR TO CONSTRUCTION WITH SLURRY
PUMPED TO 3' BELOW EXISTING SLAB ELEVATION.
KEY NOTE
31184
1/16/2027
P L O
T T
E l p m
A P
P R
O V
D A
T E
S O
N
S E
R V
A T
I O
N
S
E R
V I C
E Q
A
C o
A P
P R
O V
D A
T E
D E
P T
O
F
P
U B
L
R
K S
D M y
D o c u m e n t s D u m b
H o m e P r o j e c t s
T o r c h i o
C o u r t h o u s e C
A D
C o u r t h o u s e E
N G
B a s e d w g T a b
D e m o
PO Box 103
Centreville, MD 21617
301-529-2368 e c t
Engineering
D
R
A
F
T
BID ALTERNATES
1. DEDUCT ALTERNATE TO REMOVE WATERPROOFING THE BASEMENT ROOF EXCEPT
AS INDICATED ON WATERPROOFING DWG BE1.2 AND REMOVING THE PERIMETER
FOUNDATION DRAINS FROM THE SCOPE OF WORK.
SHEET C1.2 EXISTING STONE MONUMENT AND BENCHES, AS WELL AS THE
MAJORITY OF BRICK WALK ALONG LIBERTY STREET CAN REMAIN UNDISTURBED.
SAWCUT BRICK WALK TO CONNECT ROOF DRAINS TO EXISTING DRAINAGE INLETS
AND REPAIR BRICK SIDEWALK IN KIND .
SHEET C3.1 REDUCE LIMIT OF EXCAVATION TO ONLY WHAT IS NECESSARY TO
INSTALL THE PROPOSED ROOF DRAINS AND INSTALL WATERPROOFING INDICATED
ON WATERPROOFING DWG BE1.2 . REFER TO SHEET C3.1 AND KEY NOTE 1 TO
STOCKPILE EXCAVATED SOILS ONSITE WITH THE ADDITION OF FILTER LOG
PERIMETER CONTROLS.
EXISTING VENT PIPE TO BE REMOVED IF NOT PART OF NEW WORK.
THE EXISTING WELL TO BE ABANDONED AND SEALED IN PLACE BY OTHERS IN
ACCORDANCE WITH MARYLAND STATE REGS. IF PRESENT, EXISTING STEEL CASING
TO BE CUT DOWN BY CONTRACTOR TO LIMIT OF EXISTING SLURRY. EXISTING
STANDPIPE FOOTINGS CAN REMAIN ABANDONED IN PLACE, OR CONTACT ENGINEER
IF INTERFERENCE EXISTS.
RE-ROUTE EXISTING WIRING AND CONDUIT AS SHOWN ON SHEET C4.1 AND THE
ELECTRICAL PLANS.
NOTE THAT STAIRS SHALL REMAIN IN USE THROUGHOUT CONSTRUCTION.
CONTRACTOR SHALL NOT DAMAGE EXISTING STAIR FOOTING DURING REMOVAL OF
EXISTING CONCRETE WALK.
REMOVE EXISTING ROOF DRAIN ENTRY POINT AND ROUGHLY 10' OF UNDERGROUND
PVC PIPE WHILE ONLY DISTURBING TURF GRASS AND CAUSING NO IMPACT TO
UNDERGROUND UTILITIES, BRICK SIDEWALK, ETC. COORDINATE WITH
ENGINEER/ARCHITECT TO DISCUSS OPTIONS TO REMOVE ADDITIONAL PIPE OR TO
PROVIDE AN AS-BUILT PLAN FOR ABANDONED ROOF DRAIN PIPE TO REMAIN.
CONTRACTOR SHALL REMOVE 10 LF OF EXISTING 6" HIGH BRICK CURB ON
BASEMENT STAIR ROOF WITHOUT DAMAGING UNDERLYING CONCRETE STAIRWAY
ROOF DECK . (NOTE THAT LIMITS OF REMOVAL DO NOT INCLUDE THE "U" OF BRICK
UNDER THE EXISTING STAIRWELL HANDRAILS.) REFER TO SHEETS BE1.0 - 1.2
REGARDING SLOPE MODIFICATIONS AND WATERPROOFING DETAILS FOR THE ROOF
DECK. REFER TO SHEET C2.1 FOR GRADING INFORMATION SHOWING THE FINISHED
TURF GRASS GRADE RUNNING CONTINUOUSLY OVER TOP OF THE ROOF DECK
FROM THE COURTHOUSE WING TO THE BROADWAY CURB.
SAWCUT AT NEAREST CURB CONTROL JOINT AND BRICK WALK GROUT LINE AND
ENTRANCE. REPLACE CURB & GUTTER IN KIND.
CONTRACTOR SHALL BE AWARE OF DAILY SCHOOL BUS TRAFFIC SEASONALLY IN
THE MORNING AND AFTERNOON HOURS, AND SHALL ADJUST MAJOR DELIVERIES,
TRASH HAULING, ETC. ACCORDINGLY.
KEY NOTES
CONSTRUCTION FENCE LOCATION PLAN
SCALE: 1" = 20'
DEMOLITION NOTES
1. THE CONTRACTOR SHALL MINIMIZE TEMPORARY PARKING IN THE ON-STREET SPACES
SURROUNDING THE SUBJECT PROPERTY. CONTRACTOR PARKING AND VEHICLE/TRAILER
STORAGE IS AVAILABLE AT THE COUNTY COMMISSIONER'S PROPERTY LOCATED TO THE
NORTH OF THE "NIELSEN CENTER" BUILDING AT 205 N LIBERTY STREET. AN AREA OF
ROUGHLY 22'x136' IS AVAILABLE ON THE NORTH SIDE OF THE LOT (MAP 44C, PARCEL 882)
OUTSIDE OF THE TRAVEL LANE. SEE NEXT SHEET .
2. THE CONTRACTOR IS WELCOME TO COORDINATE WITH THE DEVELOPER FOR TEMPORARY
MATERIAL STOCKPILING AND STORAGE OF VARIOUS ITEMS AT THEIR PROPERTY AT VINCIT
STREET AND MD RTE 304 (MAP 44F, PARCEL 60, LOT 19) OR AT THE DPW YARD AT 312
SAFETY DRIVE. SUCH ITEMS MAY INCLUDE, BUT ARE NOT LIMITED TO: STONE BENCHES
AND MONUMENTS, METAL FIRES ESCAPE STAIRWAY, BUILDING SPOTLIGHT, ETC. PROVIDE
SILT FENCE AROUND ANY SOIL STOCKPILE AREAS PER DETAIL E-1 ON SHEET C3.2,
SEDIMENT & EROSION CONTROL DETAILS.
3. EXISTING UTILITY POLES, CONDUITS AND APPURTENANCES TO BE RELOCATED SHALL BE
COORDINATED WITH THE APPROPRIATE UTILITY COMPANIES.
4. THE BASE BID SHALL INCLUDE AN ITEM FOR THE CONTRACTOR TO HIRE A PRIVATE UTILITY
MARKING FIRM TO VERIFY AND SUPPLEMENT THE MARKINGS PROVIDED BY MISS UTILITY.
TREE PROTECTION
LUMBER WRAP (TYP. OF 9)
SEE DETAIL SHEET C1.3
SUGGESTED
ROLL-OFF
DUMPSTER
LOCATION
5. THE OWNER/ENGINEER HAS CONTRACTED DIRECTLY WITH SKYLINE TECHNOLOGY SOLUTIONS TO
UPGRADE THE FIBER OPTIC SERVICE THROUGH AND SERVING THE COURTHOUSE SITE. THE CONTRACTOR SHALL
INSTALL THE REQUIRED HAND HOLE BOXES AND CONDUIT WITH TRACER WIRE AND MULE TAPE AS SHOWN ON SHEETS
C4.1 AND C4.2. SKYLINE WILL INSTALL FIBER OPTIC CABLING UTILIZING THE CONTRACTOR-INSTALLED CONDUIT FROM
HANDHOLE TO THE DMARC, AND MAKE ALL REQUIRED SPLICES/TERMINATIONS. CONTRACTOR SHALL COORDINATE HIS
WORK WITH SKYLINE AND INITIATE THE SPECIFIED PRE-CONSTRUCTION MEETING. CONTRACTOR SHALL PROVIDE
WRITTEN NOTICE TO THE ENGINEER IN THE EVENT OF CONFLICT OR DISCREPANCY BETWEEN THE SKYLINE AND CIVIL
DRAWINGS.
NOTE: CONTRACTOR SHALL SUBMIT A SITE UTILIZATION PLAN
SHOWING LOCATION OF DUMPSTER(S), CONSTRUCTION TRAILER(S),
CONSTRUCTION FENCE, MATERIAL STAGING, ETC. TO THE ENGINEER
FOR REVIEW PRIOR TO START OF CONSTRUCTION.
SEE SHEET C2.2 FOR SEWER DETAILS
AND BRICK WALK REMOVAL DETAIL
P L O
T T
E l p m
A P
P R
O V
D A
T E
S O
N
S E
R V
A T
I O
N
S
E R
V I C
E Q
A
C o
A P
P R
O V
D A
T E
D E
P T
O
F
P
U B
L
R
K S
D M y
D o c u m e n t s D u m b
H o m e P r o j e c t s
T o r c h i o
C o u r t h o u s e C
A D
C o u r t h o u s e S i t e
P l a n d w g T a b e t
PO Box 103
Centreville, MD 21617
301-529-2368 e c t
Engineering
D
R
A
F
T
BID ALTERNATES
1. DEDUCT ALTERNATE TO REMOVE WATERPROOFING THE BASEMENT ROOF EXCEPT
AS INDICATED ON WATERPROOFING DWG BE1.2 AND REMOVING THE PERIMETER
FOUNDATION DRAINS FROM THE SCOPE OF WORK.
SHEET C1.2 EXISTING STONE MONUMENT AND BENCHES, AS WELL AS THE
MAJORITY OF BRICK WALK ALONG LIBERTY STREET CAN REMAIN UNDISTURBED.
SAWCUT BRICK WALK TO CONNECT ROOF DRAINS TO EXISTING DRAINAGE INLETS
AND REPAIR BRICK SIDEWALK IN KIND .
SHEET C3.1 REDUCE LIMIT OF EXCAVATION TO ONLY WHAT IS NECESSARY TO
INSTALL THE PROPOSED ROOF DRAINS AND INSTALL WATERPROOFING INDICATED
ON WATERPROOFING DWG BE1.2 . REFER TO SHEET C3.1 AND KEY NOTE 1 TO
STOCKPILE EXCAVATED SOILS ONSITE WITH THE ADDITION OF FILTER LOG
PERIMETER CONTROLS.
NOT TO SCALE
TREE PROTECTION LUMBER WRAP DETAIL
NOT TO SCALE
CONSTRUCTION DETAIL
2-3"
8'-0"
12"
2" DIA. GALV. TUBING (TYP.) WITH
CORNER REINFORCEMENT
NOTES:
1. PROVIDE CONCRETE BASE BLOCKS WITH 2 HOLES EACH TO ACCEPT
VERTICAL POSTS. WEIGHT BLOCKS TO PROVIDE ADEQUATE STABILITY
FOR 40 MPH WIND GUSTS.
2. PROVIDE CLIPS TO CONNECT ADJACENT FENCE SECTIONS.
3. GATES MAY CONSIST OF MOVABLE SECTIONS OF FENCE WITH CLIPS
REMOVED.
NOT TO SCALE
22' x 136' PARKING
AREA. STRIPED
BY OWNER
NOT TO SCALE
OFFSITE STORAGE AT VINCIT STREET
RUTHSBURG RD
(MD ROUTE 304)
QAC HIGH
SCHOOL
YMCA
PLAN
1. TEMPORARY USE OF THIS PROPERTY FOR ANY
PURPOSE IS ENTIRELY OPTIONAL. SHOULD
THE CONTRACTOR DECIDE TO DO SO, THEY
SHALL BE ENTIRELY RESPONSIBLE FOR THE
PLANNING AND PERMITTING (I.E. GRADING
PERMIT) REQUIRED TO USE THE PROPERTY
FOR THE DESIRED USE, AND AT THEIR
EXPENSE.
2. CONTRACTOR SHALL COORDINATE WITH THE
OWNER AT LEAST 2 WEEKS BEFORE UTILIZING
THIS PROPERTY FOR ANY PURPOSE TO
DISCUSS AND COORDINATE
MOWING/CLEARING, ACCESS LOCATION(S),
FENCING HOURS OF OPERATION, ETC.
3. CONTRACTOR IS RESPONSIBLE FOR PROVIDING
CONSTRUCTION FENCING FOR SECURITY
PURPOSES AND PUBLIC SAFETY AT THEIR
EXPENSE FOR THE ENTIRE TIME THE PARCEL IS
IN USE.
4. IF THIS PARCEL IS TO BE USED FOR ANY
PURPOSE, CONTRACTOR SHALL INSTALL A
STABILIZED CONSTRUCTION ENTRANCE AT
EVERY VEHICLE ENTRANCE LOCATION AT
THEIR EXPENSE.
5. IF ANY TOPSOIL, SOIL, OR AGGREGATE
MATERIAL, SUCH AS CR-6, IS TO BE STORED ON
THIS PARCEL, THE STOCKPILE AREA SHALL BE
SURROUNDED ON ALL SIDES WITH SILT FENCE
PER DETAIL E-1 ON SHEET C3.2 AT THEIR
EXPENSE. WASHED STONE THAT IS PEA
GRAVEL OR LARGER, IS EXEMPT FROM THIS
REQUIREMENT.
OPTIONAL USE NOTES
STORAGE LOT IS 2.0 MILES FROM THE
CONSTRUCTION SITE, ROUND TRIP.
FIRE SAFETY PLAN - 400' HYDRANT CIRCLES - SEE SHEET C4.1
SCALE: 1"=60'
NOTE, THE ENTIRETY OF THE
EXISTING BUILDING FALLS WITHIN
SIX (6) HYDRANT CIRCLES AND IS
WITHIN 500' OF THE FIRE
DEPARTMENT BUILDING
PLAN
FIRE HYDRANT #2
FIRE HYDRANT #3
FIRE HYDRANT #5
FIRE HYDRANT #4
FIRE HYDRANT #1
400' RADIUS FIRE
HYDRANT CIRCLE
PATH OF HOSE
DRAG FROM
HYDRANT #5
FIRE HYDRANT #6
GOODWILL VOLUNTEER
FIRE DEPARTMENT
BUILDING
OFFSITE PARKING NEAR NIELSEN BUILDING
PROVIDE ONE PUBLIC
PARKING SIGN PER
DETAIL THIS SHEET
W11-2 PEDESTRIAN SIGN DETAIL
NOT TO SCALE
1. SIGN SHALL BE LOCATED 2' TO 3' BEHIND EDGE
SIDEWALK, AND BESIDE THE EXISTING SIGN
READING "DEPARTMENT OF COMMUNITY SERVICES.
FINAL LOCATION TO BE APPROVED BY ENGINEER.
2. PROVIDE 24" x 24" BLUE SIGN WITH WHITE "P" AND
RIGHT-POINTING WHITE ARROW, 1.5" ROUNDED
CORNERS, AND STANDARD ENGINEER-GRADE
REFLECTIVE SURFACE
3. SIGN MATERIAL SHALL BE 80 MIL ALUMINUM
POST SECTION
MOUNTING
3 1/2"
1 1/4"
4 LB/FT "U"
CHANNEL
(GALVANIZED)
5/16" MACHINE
SCREW OR
BOLT
NUT AND
LOCK
WASHER
SIGN
F R
O N
T
D
E P
T H
F
G
R E
A T
E R
M
I N
M
I N
I M
U M
10"
P
C
D
E S
POST & MOUNTING
PER DETAILS AT LEFT
MOWING
EDGE
CONCRETE
FOOTING
POST
SIGN GRAPHIC
SITE PLAN
SCALE: 1"=10'
31184
1/16/2027
P L O
T T
E l p m
A P
P R
O V
D A
T E
S O
N
S E
R V
A T
I O
N
S
E R
V I C
E Q
A
C o
A P
P R
O V
D A
T E
D E
P T
O
F
P
U B
L
R
K S
D M y
D o c u m e n t s D u m b
H o m e P r o j e c t s
T o r c h i o
C o u r t h o u s e C
A D
C o u r t h o u s e S i t e
P l a n d w g T a b i t e
PO Box 103
Centreville, MD 21617
301-529-2368 e c t
Engineering
D
R
A
F
T
BID ALTERNATES
1. DEDUCT ALTERNATE TO REMOVE WATERPROOFING THE BASEMENT ROOF EXCEPT
AS INDICATED ON WATERPROOFING DWG BE1.2 AND REMOVING THE PERIMETER
FOUNDATION DRAINS FROM THE SCOPE OF WORK.
SHEET C1.2 EXISTING STONE MONUMENT AND BENCHES, AS WELL AS THE
MAJORITY OF BRICK WALK ALONG LIBERTY STREET CAN REMAIN UNDISTURBED.
SAWCUT BRICK WALK TO CONNECT ROOF DRAINS TO EXISTING DRAINAGE INLETS
AND REPAIR BRICK SIDEWALK IN KIND .
SHEET C3.1 REDUCE LIMIT OF EXCAVATION TO ONLY WHAT IS NECESSARY TO
INSTALL THE PROPOSED ROOF DRAINS AND INSTALL WATERPROOFING INDICATED
ON WATERPROOFING DWG BE1.2 . REFER TO SHEET C3.1 AND KEY NOTE 1 TO
STOCKPILE EXCAVATED SOILS ONSITE WITH THE ADDITION OF FILTER LOG
PERIMETER CONTROLS.
EX. CONCRETE STAIR FOUNDATION TO BE MODIFIED PER DETAIL ON SHEET C2.2 TO REMOVE A
PORTION OF EXISTING CONCRETE AND ADD A NEW GALVANIZED TREAD.
PROVIDE FOUR (4) ELECTRIC PEDESTALS AND WIRING/CONDUIT. REFER TO ELECTRICAL PLANS
FOR ADDITIONAL DETAILS. EXACT LOCATION OF FIXTURES AND CONDUIT TO BE DETERMINED.
BRICK SIDEWALK ALONG THE BROADWAY CURB LINE AT 2% MINIMUM AND 5% FOR 10' AWAY FROM
THE BUILIDING WHEREVER POSSIBLE. REFER TO SHEETS BE1.0 - 1.2 REGARDING SLOPE
MODIFICATIONS AND WATERPROOFING DETAILS FOR THE ROOF DECK.
PROVIDE DUPLEX 1 HP SUMP PUMPS PLUMBED TO A COMBINED 1
" FORCE MAIN DISCHARGING
INTO THE NEAREST NYLOPLAST CATCH BASIN. DO NOT CONNECT TO THE ROOF DRAIN PIPE.
PACKAGE SHALL INCLUDE NEW ELECTRICAL SERVICE IN CONDUIT, FLOAT SWITCHES, AND HIGH
WATER ALARM LIGHT WITH BUZZER. SEE ELECTRICALS.
CONNECT PROPOSED 6" PVC (SDR-35) ROOF DRAINS TO EXISTING 18" NYLOPLAST INLETS WITH
(SDR-35) PERIMETER FOUNDATION DRAINS TO EXISTING 18" NYLOPLAST INLETS WITH
COORDINATE WITH ELECTRIC UTILITY OWNER TO PROVIDE NEW UTILITY SERVICE FROM POLE AT
CORNER OF LIBERTY ST. AND BROADWAY TO LOCATION SHOWN ON ELECTRICAL DRAWINGS.
REMOVE AND RECYCLE/DISCARD EXISTING GUARDRAIL AND STAIRWAY HANDRAILS. REMOVE AND
RECYCLE/DISCARD EXISTING LIGHT POLE (SEE ELECTRICALS FOR REPLACEMENT). ENSURE TOP
OF BRICK "U" AROUND STAIRS, INCLUDING POST HOLES, ARE SEALED TO PREVENT WATER
INTRUSION INTO UNDERLYING STRUCTURE. CLEAN EXISTING TOP OF BRICK WITH ACID WASH
AND INSTALL AN ADDITIONAL COURSE OF ROWLOCK BRICK TO MATCH EXISTING. INSTALL
PROPOSED GUARDRAIL AND STAIRWAY HANDRAILS PER DETAIL ON SHEET C2.2.
TURN UP 4" ROOF DRAIN PIPES TO ACCEPT FLOW FROM DOWNSPOUT BOOTS (SEE
ARCHITECTURALS FOR DOWNSPOUT AND BOOT LOCATIONS). ROOF DRAIN PIPES SHALL BE A
MINIMUM DIAMETER OF 4" PVC (SDR-35) AT 2.0% MINIMUM SLOPE WHEREVER THEY CONNECT TO A
DOWNSPOUT BOOT. ROOF DRAIN COLLECTOR PIPES SHALL BE 6" PVC (SDR-35) AT 2.0% MIN.
COORDINATE WITH THE MEP PLANS TO PROVIDE AN "EL"-SHAPED 1" DIAMETER ELECTRICAL
CONDUIT UNDER THE LOCATION OF THE PROPOSED IRRIGATION CONTROLLER, INSIDE THE
EQUIPMENT ENCLOSURE. THE CONDUIT SHALL EXTEND UP A MINIMUM OF 12" ABOVE THE SLAB, AND SHALL EXIT THROUGH THE MASONRY WALL ROUGHLY 12" BELOW THE EXTERIOR GRADE.
PROVIDE A LONG-SWEEP BEND TO FACILITATE RUNNING IRRIGATION CONTROL WIRES SOUTH TO
THE EXISTING IRRIGATION BOX.
PROVIDE 16 LF OF 4" PVC (SCHED 40) PIPE TO ACT AS A SLEEVE FOR EASY CONNECTION OF
SPRINKLER MAINS BETWEEN THE SOUTH SIDE CONTROL-BOX AND THE NORTH-SIDE LAWN.
SLEVES SHALL BE 2" MINIMUM BELOW THE BRICK SIDEWALK PAVERS. PROVIDE TEMPORARY
TAPED CAPS TO KEEP SLEEVES CLEAN UNTIL NEEDED.
KEY NOTES
MATCHLINES
REFER TO SHEET C3.1 FOR EARTHWORK TRENCHING AND EXCAVATION RELATED TO
WATERPROOFING AND INSTALLATION OF ROOF DRAINS AND OPTIONAL FRENCH DRAINS.
REFER TO ARCHITECTURALS AND SHEETS BE1.0 - 1.2 FOR WATERPROOFING DETAILS.
COORDINATION NOTE:
NOT TO SCALE
EQUIPMENT ENCLOSURE DETAIL
SEE 4/E501 FOR GENERATOR
PAD DETAIL, WHICH SHALL BE
CONSTRUCTED BEFORE THE
SURROUNDING CONCRETE
SLAB. TOP ELEV = 62.10
PROPOSED UTILITY
TUNNEL. SEE
ARCHITECTURALS
ENSURE 1.5" MIN. GAP
BELOW GATES TO ALLOW
FOR WATER DRAINAGE
CONTROL JOINT
(TPYICAL)
NOTES:
1. SEE MEP SHEETS FOR RELEVANT DETAILS AND LOCATION OF GENERATOR PAD .
2. SEE 2/S2.2 FOR 6" THICK CONCRETE PAVING AND EQUIPMENT HOUSEKEEPING PAD
3. COORDINATE LOCATION INSIDE EQUIPMENT ENCLOSURE FOR IRRIGATION CONTROLLERS.
PROVIDE 1" MIN. DIA. ELECTRICAL CONDUIT WITH LONG-SWEEP ELBOW FOR CONTROL
WIRING (WIRING BY OTHERS). CONDUIT SHALL EXTEND 48" ABOVE CONC. SLAB AND 24"
MIN OUTSIDE MASONRY WALL. PROVIDE 2 TAPED CAPS AND TEMPORARY STAKE
MARKING BURIED CAP LOCATION.
4. PROVIDE EXPANSION JOINTS BETWEEN THE CONCRETE PAVING AND THE GENERATOR
PAD AS WELL AS ANY VERTICAL WALLS, EXISTING OR PROPOSED. JOINTS SHALL BE
WIDE WITH PREFORMED EXPANSION JOINT MATERIAL.
5. PROVIDE TOOLED OR SAWCUT CONTROL JOINTS TO SUIT THE LAYOUT SHOWN ON THE
EQUIPMENT ENCLOSURE DETAIL, THIS SHEET. REFER TO CONTROL JOINT DETAIL 12/S2.1.
6. PROVIDE A BROOM FINISH FOR CONCRETE PAVING AND SMOOTH HOUSEKEEPING PADS.
SEE NOTE 3
SEE NOTE 3
P L O
T T
E l p m
A P
P R
O V
D A
T E
S O
N
S E
R V
A T
I O
N
S
E R
V I C
E Q
A
C o
A P
P R
O V
D A
T E
D E
P T
O
F
P
U B
L
R
K S
D M y
D o c u m e n t s D u m b
H o m e P r o j e c t s
T o r c h i o
C o u r t h o u s e C
A D
C o u r t h o u s e S i t e
P l a n d w g T a b t
PO Box 103
Centreville, MD 21617
301-529-2368 e c t
Engineering
D
R
A
F
T
BID ALTERNATES
1. DEDUCT ALTERNATE TO REMOVE WATERPROOFING THE BASEMENT ROOF EXCEPT
AS INDICATED ON WATERPROOFING DWG BE1.2 AND REMOVING THE PERIMETER
FOUNDATION DRAINS FROM THE SCOPE OF WORK.
SHEET C1.2 EXISTING STONE MONUMENT AND BENCHES, AS WELL AS THE
MAJORITY OF BRICK WALK ALONG LIBERTY STREET CAN REMAIN UNDISTURBED.
SAWCUT BRICK WALK TO CONNECT ROOF DRAINS TO EXISTING DRAINAGE INLETS
AND REPAIR BRICK SIDEWALK IN KIND .
SHEET C3.1 REDUCE LIMIT OF EXCAVATION TO ONLY WHAT IS NECESSARY TO
INSTALL THE PROPOSED ROOF DRAINS AND INSTALL WATERPROOFING INDICATED
ON WATERPROOFING DWG BE1.2 . REFER TO SHEET C3.1 AND KEY NOTE 1 TO
STOCKPILE EXCAVATED SOILS ONSITE WITH THE ADDITION OF FILTER LOG
PERIMETER CONTROLS.
NOT TO SCALE
4" PERFORATED STORM DRAIN PIPE DETAIL
4" PERFORATED PERIMETER
FOUNDATION DRAIN DETAIL
NOT TO SCALE
2:00
4:008:00
DOWN (6:00)
UP (12:00)
T
Y
P
" DIA.
HOLES
EVERY 6"
(USE THIS DETAIL IF DRILLING PERFORATIONS MANUALLY)
STORMWATER CLEANOUT DETAIL
NOT TO SCALE
FLOW
6"x4" WYE FOR
ROOF DRAIN, 4"x4"
FOR PERFORATED
STORM DRAIN
FINISHED GRADE
OPTIONAL FOR ROOF
BELOW GRADE AND
PROVIDE 12" OF #4 REBAR
FOR MAGNETIC LOCATION
ROOF DRAIN AND
E X
I S
T I N
G
B A
S E
M E
N T
PROPOSED WATERPROOFING
& INSULATION (NOT SHOWN)
PER ARCHITECTURALS AND
SHEETS BE1.0 - 1.2
DRAINAGE AND
PROTECTION BOARD
FILTER FABRIC PER
NOTE 4 OVERLAPPED
MIN. 24" ON ROOF
8" - 12"
18" - 24"
V A
R I E
S
T
O
FILL #2 SELECT FILL
COMPACTED TO
ROOF DRAIN HAUNCH
FILL AREA #1
#57 DOUBLE-
WASHED STONE
FILL AREA #3
COMMON FILL
IMPERVIOUS
MEMBRANE PER
NOTE 3
NOTES:
1. REFER TO ARCHITECTURALS AND SHEETS BE1.0 - 1.2 FOR WATERPROOFING DETAIL S.
2. SEE PLAN VIEW FOR ORIENTATION AND PIPE LOCATIONS. NOTE THAT THE 4" PERFORATED STORM DRAIN
SHALL BE CONSTRUCTED FIRST, CONSIDERING IT IS LOWER IN THE GROUND.
3. ROOF DRAIN ENTERS THE EXISTING CATCH BASINS LOWER THAN THE PERFORATED STORM DRAIN TO
PREVENT BACKFLOW UP THE STORM DRAIN PIPE.
4. IMPERVIOUS MEMBRANE SHALL BE 40 mil EPDM OR EQUAL, COORDINATE WITH ROOFING CONTRACTOR.
5. FILTER FABRIC SHALL BE CLASS "C" GEOTEXTILE SUCH AS: AMOCO 4552, GEOLON N 70, WEBTEC N
07,CARTHAGE FX-80 S, OR MIRAFI 180-N.
6. CONTRACTOR SHALL PROVIDE ENGINEER AND OWNER WITH: ALL MATERIAL TICKETS, DIGITAL PICTURES
DOCUMENTING PIPES BEFORE BACKFILLING FOR EACH STEP OF PIPE INSTALLATION, AND REDLINE PLANS
SHOWING AS-BUILT DIMENSIONS.
7. PROVIDE 6" METALLIC DETECTION TAPE, 12" ABOVE ALL UNDERGROUND PIPES
ADHERED SHEET
MEMBRANE
SCHEDULE
40 PIPE
NOT TO SCALE
BRICK PAVER DETAIL
APPROVED
SUBGRADE
4" CONCRETE
BRICK TO MATCH EXISTING
AND PER ENGINEER/
ARCHITECT
SLOPE 1% MIN, 2% MAX
MORTARED JOINTS TO
MATCH EXISTING
" MIN. MIXTURE OF 4
PARTS SAND AND 1 PART
PORTLAND CEMENT
BETWEEN CONCRETE
FOUNDATION AND BRICK
NOTES:
1. CONCRETE SHALL BE SHA MIX No. 3.
2. BRICK MATERIAL AND PATTERN SHALL MATCH EXISTING RUNNING BOND WITH PERPENDICULAR
EDGING.
3. EXPANSION JOINTS AT INTERVALS NOT GREATER THAN 50'IN BOTH CONCRETE AND BRICK.
4. FILL UP TO SIDEWALK EDGE WITH COMMON FILL AND 4" TOPSOIL AND EITHER SOD FOR AREAS
ABOVE THE BASEMENT ROOF OR SEED AND MULCH IN OTHER AREAS.
5. GRASS AREAS ADJACENT TO THE SIDEWALK SHOULD SLOPE AT 1% MIN. TO THE ADJACENT STREET.
6. MAXIMUM LONGITUDINAL SLOPE IN THE DIRECTION OF TRAVEL SHALL BE 5%, EXCLUSIVE OF
HANDICAP RAMPS, WHICH SHALL BE SLOPED AT A MAXIMUM OF 1:12.
7. ALL BRICK SIDEWALKS AND RAMPS SHALL COMPLY WITH ADA REQUIREMENTS PER THE MOST
UP-TO-DATE STATE AND FEDERAL REGULATIONS.
MODIFICATION DETAIL
NOT TO SCALE
EXISTING STAIR FOOTING
NOTES:
1. PROPOSED DIAMOND-TREAD GALVANIZED STEEL
STAIR TREAD TO MIMIC EXISTING. TREAD SHALL HAVE
REAR "U" REINFORCING REMOVED TO SIT FLAT ON
EXISTING CONCRETE. TREAD SHALL FIT WITHIN THE
EXISTING STAIR STRINGERS WITH
" SIDE CLEARANCE.
TREAD SHALL SIT ON BLACK 60 MIL EPDM MEMBRANE
TRIMMED TO MATCH TREAD DIMENSIONS. FASTEN
TREAD IN PLACE WITH SIX 2.5" TAPCON FLAT-HEAD
MASONRY SCREWS THROUGH MEMBRANE AND
COUNTERSUNK FLUSH WITH STAIR TREAD.
PROPOSED CROSS SECTION
REMOVE 10" OF
PREVIOUSLY ADDED
CONCRETE
EX. CONC. FOOTING
EX. CONC. WALK
ELEV=59.83
EX. FOOTING
EX. STAIRS AND
HANDRAIL TO
REMAIN
" PARGE ON FACE
OF EX. CONCRETE
PROPOSED
BRICK WALK
ELEV=59.70
(7" RISER)
SEE NOTE 1
PROPOSED CROSS SECTION
4.2%
EXISTING CONDITIONS PHOTO
EXISTING PREVIOUSLY
ADDED CONCRETE TO BE
REMOVED AT EXISTING JOINT
4" PERFORATED
PVC (SDR-35)
PERIMETER
FOUNDATION DRAIN
AT 1.0% SLOPE MIN.
6" SOLID PVC
(SDR-35) ROOF
DRAIN AT 1.0%
SLOPE MIN.
D E
P T
H
V
A R
I E
S
S
L O
P E
(DETAIL DOES
NOT APPLY TO
ROOF DRAINS)
PERIMETER
FOUNDATION
DRAIN
ROOF DRAIN
SEE
NOTE 7
SEE NOTE 7
EXISTING BRICK WALK, BENCHES
AND MONUMENT DETAIL
NOT TO SCALE
SEE SHEET C1.2. EXISTING BRICK WALK, BENCHES AND MONUMENT TO BE RECONSTRUCTED
AT COMPLETION OF PROJECT. STONE AND METAL COMPONENTS TO BE STORED DURING
THE DEMOLITION PHASE AND PROTECTED FROM DAMAGE AT CONTRACTOR'S EXPENSE.
NOT TO SCALE
BRICK PAVER REMOVAL DETAIL
CROSS-HATCHED AREA
REPRESENTS THE BRICK
PAVER AREA OF 5,150
SQFT TO BE REMOVED IN
THE BASE BID
SEDIMENT & EROSION CONTROL PLAN
SCALE: 1"=10'
"FOLLOWING INITIAL SOIL DISTURBANCE OR
REDISTURBANCE, PERMANENT OR TEMPORARY
STABILIZATION SHALL BE COMPLETED WITHIN THREE
CALENDAR DAYS AS TO THE SURFACE OF ALL PERIMETER
CONTROLS, DIKES, SWALES, DITCHES, PERIMETER SLOPES,
AND ALL SLOPES GREATER THAN 3 HORIZONTAL TO 1
VERTICAL (3:1); AND SEVEN DAYS AS TO ALL OTHER
DISTURBED OR GRADED AREAS ON THE PROJECT SITE."
STANDARD STABILIZATION NOTE
NOTE:
EROSION AND SEDIMENT CONTROL
WILL BE STRICTLY ENFORCED.
TOTAL SITE AREA 36,650 SQ.FT.
LIMIT OF DISTURBANCE (ONSITE) 19,935 SQ.FT
PROPOSED IMPERVIOUS AREA 10,860 SQ.FT
VEGETATIVELY STABILIZED AREA 9,075 SQ.FT
SEDIMENT & EROSION CONTROL
SITE INFORMATION:
1. CONTACT THE QUEEN ANNE'S COUNTY DEPARTMENT OF PUBLIC WORKS AT 1-410-758-0925 AND THE
TOWN OF CENTREVILLE DPW AT 410-758-1180, A MINIMUM OF TWO (2) WEEKS PRIOR TO THE START
OF CONSTRUCTION TO SCHEDULE A PRE-CONSTRUCTION MEETING. (2 WEEKS)
2. CONTACT MISS UTILITY TO HAVE ALL ONSITE AND OFFSITE UTILITIES MARKED AND VERIFY ALL
MARKINGS WITH THE CONTRACTOR'S UTILITY LOCATION SERVICE. ( 2 WEEKS)
3. INSTALL STABILIZED CONSTRUCTION ENTRANCE, TREE PROTECTION LUMBER WRAP (SHEET C1.3), AND PERIMETER CONSTRUCTION FENCE (SHEET C1.3). (4 DAYS)
4. BEGIN BUILDING RENOVATIONS. NOTE THAT MANY OF THE FOLLOWING TASKS ARE ANTICIPATED
TO BE PERFORMED AT THE SAME TIME. TIME FRAMES LISTED ARE FOR THE TIME TO COMPLETE
EACH TASK AND DO NOT REPRESENT TIME SAVINGS BY OVERLAPPING TASKS. (MANY MONTHS)
5. SAWCUT EX. CONCRETE INSIDE EQUIPMENT CORRAL AND REMOVE SLAB AS INDICATED ON SHEET
C1.2. IF NECESSARY, CUT DOWN THE EXISTING WELL CASING BELOW GRADE. (1 WEEK)
6. WATERPROOF THE BASEMENT ROOF UNDER THE EXISTING EQUIPMENT CORRAL AS EXPLAINED IN
THE ARCHITECTURALS (3 WEEKS)
7. REMOVE EXISTING WATER METER AND EXTEND 6" PVC WATER SERVICE INTO THE BUILDING CRAWL
SPACE. INSTALL FIRE DEPARTMENT CONNECTION AND SIGN. (3 WEEKS)
8. CONTINUE WITH BUILDING RENOVATIONS. AS CONSTRUCTION COMPLETION IS NEARING, PERFORM
THE FOLLOWING TASKS IN ANY ORDER: (MANY MORE MONTHS)
9. INSTALL PERIMETER FILTER LOGS, AND EXCAVATE TO EXPOSE THE BASEMENT ROOF, REMOVING
SPOIL MATERIALS TO AN APPROVED OFFSITE DISPOSAL SITE. PERFORM WORK ASSOCIATED WITH
THAT JOB, SUCH AS INSTALLATION OF THE PERIMETER PERFORATED STORM DRAIN. (8 WEEKS)
10. INSTALL FILTER LOGS IF NOT ALREADY IN PLACE. INSTALL ROOF DRAINS, INLETS, ETC.
COORDINATE INLET LOCATIONS WITH DOWNSPOUT BOOTS LOCATIONS. (3 WEEKS)
11. RE-INSTALL SPOT LIGHT AND AND REHABILITATE PUMP CHAMBER PER PLAN, INCLUDING
ELECTRICAL WORK. (1 WEEK)
12. ONCE ITEMS 9 - 11 ARE COMPLETE, FILL THE WORK AREA ABOVE THE ROOF DRAINS AND BASEMENT
ROOF TO MIMIC EXISTING GRADES AND STABILIZE WITH 4" TOPSOIL AND SOD. SPREAD WEED/FEED
TIME-RELEASE SOIL AMENDMENTS AT RECOMMENDED INTERVALS THROUGHOUT CONSTRUCTION.
CONTRACTOR SHALL MINIMIZE WORK ACTIVITIES OVER THE SODDED AREA FOR THE REMAINDER
OF CONSTRUCTION. (2 WEEKS)
13. CONSTRUCT UTILITY TUNNEL BETWEEN THE BASEMENT AND EQUIPMENT CORRAL AND
WATERPROOF BASEMENT ROOF UNDER THE EXISTING 6' CORRAL WALLS. CONTINUE MECHANICAL
AND ELECTRICAL CONNECTIONS IN THIS AREA AND POUR NEW CONCRETE SLAB WITHIN THE
EQUIPMENT ENCLOSURE TO SUPPORT MECHANICAL EQUIPMENT. (4 WEEKS)
14. INSTALL A NEW UNDERGROUND ELECTRICAL SERVICE LINE, METER, AND TRANSFORMER.
(2 WEEKS)
15. CONSTRUCT AND/OR PATCH REMAINING BRICK WALKS. REPAIR AFFECTED WALKS AROUND ROOF
DRAINS, INLETS AND ELECTRICAL CONDUIT IN FRONT OF THE BUILDING. (2 WEEKS)
16. COMPLETE ANY REMAINING CONSTRUCTION TASKS (INTERIOR AND EXTERIOR), REMOVE TRASH
AND DEBRIS, AND STABILIZE ANY REMAINING OPEN AREAS WITH 4" TOPSOIL AND SOD. (1 MONTH)
17. UPON APPROVAL FROM THE SITE INSPECTOR, REMOVE ALL TEMPORARY SEDIMENT AND EROSION
CONTROL DEVICES. (3 DAYS)
31184
1/16/2027
P L O
T T
E l p m
A P
P R
O V
D A
T E
S O
N
S E
R V
A T
I O
N
S
E R
V I C
E Q
A
C o
A P
P R
O V
D A
T E
D E
P T
O
F
P
U B
L
R
K S
D M y
D o c u m e n t s D u m b
H o m e P r o j e c t s
T o r c h i o
C o u r t h o u s e C
A D
C o u r t h o u s e S i t e
P l a n d w g T a b
C
PO Box 103
Centreville, MD 21617
301-529-2368 e c t
Engineering
D
R
A
F
T
BID ALTERNATES
1. DEDUCT ALTERNATE TO REMOVE WATERPROOFING THE BASEMENT ROOF EXCEPT
AS INDICATED ON WATERPROOFING DWG BE1.2 AND REMOVING THE PERIMETER
FOUNDATION DRAINS FROM THE SCOPE OF WORK.
SHEET C1.2 EXISTING STONE MONUMENT AND BENCHES, AS WELL AS THE
MAJORITY OF BRICK WALK ALONG LIBERTY STREET CAN REMAIN UNDISTURBED.
SAWCUT BRICK WALK TO CONNECT ROOF DRAINS TO EXISTING DRAINAGE INLETS
AND REPAIR BRICK SIDEWALK IN KIND .
SHEET C3.1 REDUCE LIMIT OF EXCAVATION TO ONLY WHAT IS NECESSARY TO
INSTALL THE PROPOSED ROOF DRAINS AND INSTALL WATERPROOFING INDICATED
ON WATERPROOFING DWG BE1.2 . REFER TO SHEET C3.1 AND KEY NOTE 1 TO
STOCKPILE EXCAVATED SOILS ONSITE WITH THE ADDITION OF FILTER LOG
PERIMETER CONTROLS.
ALTERNATE 1: TEMPORARY SPOILS FROM ROOF DRAIN INSTALLATION MAY BE PLACED IN THE LAWN
AREA OUTSIDE OF THE SUBTERRANEAN BASEMENT IF ALTERNATE 1 IS IMPLEMENTED. IN THIS CASE, PROVIDE PERIMETER 6" FILTER LOGS INSIDE PERIMETER WALKS. TEMPORARY EXCAVATION WITHIN
STRUCTURALS PER KEY NOTE 2.
COORDINATE WITH THE OWNER TO VERIFY THE BASE BID INTENT TO DISPOSE OF ALL EXCAVATED
MATERIALS. OWNER MAY ALSO REQUEST AN ADD ALTERNATE TO STOCKPILE THE EXCAVATED
MATERIAL AT THE OFFSITE STORAGE LOCATION AT VINCIT STREET, AS SHOWN ON SHEET C1.3.
WITH STRUCTURALS REGARDING THE SIZE/WEIGHT OF EQUIPMENT THAT IS ALLOWED ON THE ROOF, MAXIMUM HEIGHT OF FILL SOILS, NEED FOR TRACKING MATS, ETC. WHILE WORKING ON THE ROOF.
COORDINATE WITH SHEETS BE1.1 - 1.2. REGARDING WATERPROOFING DETAILS FOR THE ROOF.
BACKFILL THE ROOF WITH SELECT FILL AS SPECIFIED BY A GEOTECHNICAL ENGINEER. EXISTING
GRADES ARE TO BE RESTORED AFTER PLACEMENT OF SELECT FILL AND 4" OF TOPSOIL. STABILIZE
WITH SOD.
DEWATERING IS THE RESPONSIBILITY OF THE CONTRACTOR AS MAY BE REQUIRED DURING THE
ENTIRETY OF CONSTRUCTION, EITHER DUE TO SITE CONDITIONS OR AS MAY BE REQUIRED BY THE
MDE INSPECTOR.
KEY NOTES
P L O
T T
E l p m
A P
P R
O V
D A
T E
S O
N
S E
R V
A T
I O
N
S
E R
V I C
E Q
A
C o
A P
P R
O V
D A
T E
D E
P T
O
F
P
U B
L
R
K S
D M y
D o c u m e n t s D u m b
H o m e P r o j e c t s
T o r c h i o
C o u r t h o u s e C
A D
C o u r t h o u s e S i t e
P l a n d w g T a b t
PO Box 103
Centreville, MD 21617
301-529-2368 e c t
Engineering
D
R
A
F
T
THE FOLLOWING ITEMS HAVE BEEN ADDRESSED TO MEET THE REQUIREMENTS OF THE GENERAL PERMIT FOR STORMWATER
ASSOCIATED WITH CONSTRUCTION ACTIVITY (NPDES NUMBER MDRC, STATE DISCHARGE PERMIT NUMBER 14GP).
1) UTILIZATION OF ENVIRONMENTAL SITE DESIGN
2) MAINTENANCE OF LIMITS OF DISTURBANCE TO PROTECT NATURAL AREAS
3) CONTROL OF CONSTRUCTION EQUIPMENT AND VEHICLES
4) EVALUATION AND APPROPRIATE LIMITATION OF SITE CLEARING
5) EVALUATION AND DESIGNATION OF SITE AREA FOR PHASING OR SEQUENCING
6) IDENTIFICATION OF SOILS AT HIGH RISK FOR EROSION AND ADVANCED STABILIZATION TECHNIQUES TO BE USED
7) IDENTIFICATION OF STEEP SLOPES AND DESIGNATION OF LIMITATIONS ON CLEARING THEM
8) EVALUATION AND DESIGNATION OF STABILIZATION REQUIREMENTS AND TIME LIMITS AND PROTECTION MEASURES FOR
DISCHARGES TO THE CHESAPEAKE BAY, IMPAIRED WATERS OR WATERS WITH AN ESTABLISHED TOTAL MAXIMUM DAILY
LOAD (TMDL).
GENERAL PERMIT REQUIREMENTS
SCD PLAN INFORMATION
COUNTY: QUEEN ANNE'S COUNTY
APPROVING AUTHORITY: QUEEN ANNE'S COUNTY SCD
OWNER'S NAME: COMMISSIONERS OF QUEEN ANNE'S COUNTY
OWNER'S ADDRESS: 107 N LIBERTY ST
CENTREVILLE, MD 21617
410-758-4098
DEVELOPER'S NAME: QAC DEPARTMENT OF PUBLIC WORKS
DEVELOPER'S ADDRESS: 312 SAFETY DR
CENTREVILLE, MD 21617
DEVELOPER'S PHONE: 410-758-0925
PLAN: SITE AND CONSTRUCTION QAC HISTORIC COURTHOUSE
RENOVATION PROJECT
FOR INFORMATION CONTACT: STEVE LAYDEN, P.E.
PHONE: 301-529-2368
CONTRACTOR'S NAME:
CONTRACTOR'S ADDRESS:
CONTRACTOR'S PHONE:
SITE NAME: HISTORIC COURTHOUSE RENOVATION
SITE ADDRESS: 100 COURTHOUSE SQ, CENTREVILLE, MD 21617
SCD APPROVAL NUMBER:
P L O
T T
E l p m
A P
P R
O V
D A
T E
S O
N
S E
R V
A T
I O
N
S
E R
V I C
E Q
A
C o
A P
P R
O V
D A
T E
D E
P T
O
F
P
U B
L
R
K S
D M y
D o c u m e n t s D u m b
H o m e P r o j e c t s
T o r c h i o
C o u r t h o u s e C
A D
C o u r t h o u s e S i t e
P l a n d w g T a b
U t i l
PO Box 103
Centreville, MD 21617
301-529-2368 e c t
Engineering
D
R
A
F
T
AT START OF CONSTRUCTION, CONTRACTOR SHALL CLOSE VALVE TO DETERMINE
THAT THIS GATE VALVE SHUTS OFF BUILDING WATER SERVICE. NOTIFY ENGINEERS IF
THIS IS NOT THE CASE.
PROVIDE FOUR (4) ELECTRIC PEDESTALS AND WIRING/CONDUIT. REFER TO
ELECTRICAL PLANS FOR ADDITIONAL DETAILS. EXACT LOCATION OF FIXTURES AND
CONDUIT SHALL BE PROVIDED BY THE DEVELOPER DURING CONSTRUCTION.
PEDESTALS SHALL BE A BEST MATCH TO EXISTING PEDS NEAR THE COMMERCE
STREET FLAG POLES.
SAWCUT EX BRICK WALK AT MOST RECENT CUT LINE TO REMOVE EX WATER METER.
EXTEND 6" WATER SERVICE AS SHOWN, AND RECONSTRUCT BRICK WALK TO MATCH
EXISTING. INSIDE THE BUILDING, FIRE LINE BACKFLOW PREVENTER AND DOMESTIC
WATER METER PER PLUMPING PLANS. PIPE BENDS SHALL BE ADEQUATELY
BUTTRESSED TO RESIST PIPE MOVEMENT IN ANY DIRECTION. COORDINATE WORK
WITH THE TOWN OF CENTREVILLE DEPARTMENT OF PUBLIC WORKS.
PROVIDE DUPLEX 1 HP SUMP PUMPS PLUMBED TO A COMBINED 1
" FORCEMAIN
DISCHARGING INTO THE NEAREST NYLOPLAST CATCH BASIN. DO NOT CONNECT TO
THE ROOF DRAIN PIPE. PACKAGE SHALL INCLUDE NEW ELECTRICAL SERVICE IN
CONDUIT, FLOAT SWITCHES, AND HIGH WATER ALARM BUZZER. SEE ELECTRICALS.
CONTRACTOR SHALL CONTACT THE CENTREVILLE DEPARTMENT OF PUBLIC WORKS
TO WITNESS THE CAPPING AND ABANDONMENT OF THE EXISTING SEWER SERVICE
FOR THEIR RECORDS.
CONTRACTOR SHALL HIRE AN UNDERGROUND LOCATION SERVICE TO SUPPLEMENT
MISS UTILITY MARKINGS WITHIN THE LIMIT OF DISTURBANCE. CONTRACTOR SHALL
ALSO TEST-PIT AS NECESSARY BETWEEN THE BASEMENT AND EQUIPMENT
ENCLOSURE TO GAIN A COMPLETE UNDERSTANDING OF THE EXISTING UTILITIES.
THESE SERVICES SHALL BE PERFORMED AT THE START OF CONSTRUCTION (AND
THEREAFTER IF NEEDED) AS PART OF THEIR BASE BID.
THE OWNER/ENGINEER HAS CONTRACTED DIRECTLY WITH SKYLINE TECHNOLOGY
SOLUTIONS TO UPGRADE THE FIBER OPTIC SERVICE THROUGH AND SERVING THE
COURTHOUSE SITE. THE CONTRACTOR SHALL INSTALL THE REQUIRED HAND HOLE
BOXES AND CONDUIT WITH TRACER WIRE AND MULE TAPE AS SHOWN ON SHEETS C4.1
AND C4.2. SKYLINE WILL INSTALL FIBER OPTIC CABLING UTILIZING THE
CONTRACTOR-INSTALLED CONDUIT FROM HANDHOLE TO THE DMARC, AND MAKE ALL
REQUIRED SPLICES/TERMINATIONS. CONTRACTOR SHALL COORDINATE HIS WORK
WITH SKYLINE AND INITIATE THE SPECIFIED PRE-CONSTRUCTION MEETING.
CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE ENGINEER IN THE EVENT OF
CONFLICT OR DISCREPANCY BETWEEN THE SKYLINE AND CIVIL DRAWINGS. SEE
SEQUENCE NOTE ON SHEET 4.2.
KEY NOTES
FIBER OPTIC UTILITY PLAN
SCALE: 1"=10'
CONTINUED ON SHEET C4.2
SEE SHEET C1.3 FOR
FIRE SAFETY PLAN
SEE SHEETS C1.1 & C1.2
FOR EXISTING
UNDERGROUND FIBER
OPTIC CONDUITS
ABANDONED IN PLACE
SEE SHEET C2.2 FOR
SEWER DETAILS
P L O
T T
E l p m
A P
P R
O V
D A
T E
S O
N
S E
R V
A T
I O
N
S
E R
V I C
E Q
A
C o
A P
P R
O V
D A
T E
D E
P T
O
F
P
U B
L
R
K S
D M y
D o c u m e n t s D u m b
H o m e P r o j e c t s
T o r c h i o
C o u r t h o u s e C
A D
C o u r t h o u s e S i t e
P l a n d w g T a b t
PO Box 103
Centreville, MD 21617
301-529-2368 e c t
Engineering
D
R
A
F
T
FIBER OPTIC UTILITY PLAN
CONTINUED FROM SHEET C4.1
SCALE: 1"=10'
DISCLAIMER REGARDING FIBER OPTIC DESIGN:
THE FIBER OPTIC COMPONENT OF THESE SITE PLANS WERE REPRODUCED FROM PLANS
DESIGNED, DRAWN, AND PREPARED BY SKYLINE TECHNOLOGY SOLUTIONS, WHO ARE
RESPONSIBLE FOR THE ACCURACY, QUALITY, AND FITNESS OF THE FIBER OPTIC
INFRASTRUCTURE DESIGN. SKYLINE TECHNOLOGY SOLUTIONS HEREBY CERTIFIES
THAT THEY HAVE REVIEWED THESE PLANS AND HAVE FOUND THE FIBER OPTIC
COMPONENTS ON THESE PLANS TO BE ACCURATE AND CORRECT IN ALL MATERIAL
RESPECTS. STEPHEN LAYDEN, OF SELECT ENGINEERING, A SUBSIDIARY OF DUMBHOME,
LLC, AFFIXES HIS SEAL HERETO FOR THE REMAINDER OF THE THESE CONTRACT
DRAWINGS BUT BEARS NO LEGAL RESPONSIBILITY FOR THE FIBER OPTIC DESIGN.
SIGNATURE ___________________________________________ DATE _____________
PRINT NAME ___________________________________________
NOTE THAT PROPOSED FIBER OPTIC SHOWN ON THESE PLANS IS INTENDED TO BE INSTALLED
PRIOR TO MOBILIZATION OF THE GENERAL CONTRACTOR.
SKYLINE TECHNOLOGY SOLUTIONS, OR THEIR CONTRACTOR, IS CONTRACTED TO INSTALL
HANDHOLES AND CONDUIT DESIGNATED AS "SKYLINE TO INSTALL...." WHILE THESE FEATURES
ARE SHOWN AS PROPOSED IMPROVEMENTS, THEY WILL, IN FACT, BE EXISTING AT THE TIME
CONSTRUCTION COMMENCES. THESE FEATURES INCLUDE:
1. INSTALLED HANDHOLE #1 NEAR BROADWAY, OUTSIDE LIMIT OF DISTURBANCE.
2. INSTALLED 4" CONDUIT FROM HANDHOLE #1 TO EXISTING HANDHOLE OUTSIDE OF
LIBERTY BUILDING
3. REPLACED DOIT HANDHOLE #2 ON EAST SIDE OF COMMERCE ST (128 N COMMERCE ST)
4. REPLACED MDBC HANDHOLE #3 IN THE SOUTHEAST CORNER OF THE BUILDING
FIBER OPTIC SEQUENCE NOTES: