Drawing Solicitation 36C25021B0052.pdf

PDF 29 MB Posted

Attached to
36C25021B0052 - Project No. 515-20-101 - Renovate Common Areas, Various Buildings
Solicitation number
515-20-101
Issued by

About this file

This solicitation is for renovation work at various buildings at the VA Medical Center in Battle Creek, Michigan. The contractor will furnish all labor, materials, equipment, supervision, as-built documentation and related information to improve common areas in outpatient care buildings 2, 6, 8, 9, 10, 11, 12 by replacing worn ceilings, flooring, wall coverings and doors with more energy efficient and secure units. Signage and handrails will also be improved for accessibility. Entrance vestibules will be added to buildings 5, 6, 13, 14 and 82 to prevent ice from falling inside. The contractor will have 380 days to complete the work. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10.

View the file

Other files

File Type Posted
36C25021B0052 0003.docx DOCX document
515-20-101 34 AE321 - Exterior Wall Sections.pdf PDF
515-20-101 32 002-AD102 - Bldg 2 2nd Flr Demolition Plans.pdf PDF
515-20-101 32 006-AD101 - Bldg 6 Roof Demolition Plans.pdf PDF
515-20-101 32 009-AD101 - Bldg 9 1st Flr Demolition Plans.pdf PDF
515-20-101 32 002-AD100 - Bldg 2 Ground Floor Demolition Plans.pdf PDF
515-20-101 32 002-AD101 - Bldg 2 1st Flr Demolition Plans.pdf PDF
515-20-101 Addendum Answers.pdf PDF
515-20-101 32 013-AD101 - Bldg 13 Demolition Plans.pdf PDF
36C25021B0052 0002 Amendment.pdf PDF
RFI Answers for 2nd Group of Questions.pdf PDF
515-20-101 32 014-AD101 - Bldg 14 Demolition Plans.pdf PDF
515-20-101 34 AE600 - Door Sizes - Drawing.pdf PDF
515-20-101 34 082-AE101 - Plans and Elevation.pdf PDF
515-20-101 32 082-AD101 - Bldg 82 Demolition Plans.pdf PDF
515-20-101 32 008-AD101 - Bldg 8 2nd Flr Demolition Plans.pdf PDF
515-20-101 32 010-AD101 - Bldg 10 1st Flr Demolition Plans.pdf PDF
515-20-101 32 012-AD101 - Bldg 12 1st Flr Demolition Plans.pdf PDF
515-20-101 34 AE320 - Exterior Wall Sections.pdf PDF
515-20-101 32 011-AD101 - Bldg 11 1st Flr Demolition Plans.pdf PDF
515-20-101 32 005-AD101 - Bldg 5 Demolition Plans.pdf PDF
VA Signage Design Guide.pdf PDF
VA Signage Design Guide.pdf PDF
RFI Questions and Answers.pdf PDF
515-20-101 Pre-Bid Sign In Sheet.pdf PDF
36C25021B0052 0001 Amendment Update.pdf PDF
Specifications Project 515-20-101 Solicitation 36C25021B0052.pdf PDF
36C25021B0052.docx DOCX document
RFI Form-Solicitation 36C25021B0052-Project 515-20-101.docx DOCX document
515-20-101 Wage Determination.pdf PDF
EMR Certification Form 2021-Solicitation 36C25021B0052-Project 515-20-101.docx DOCX document
515-20-101 Justification for Brand Name Only Component - KABA Cores.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

U N I T

E D

STAT ES OF

A M

E R

IC

A

S

RI

A F F A

SN

AR

ETEVFO

TN

E

M T R A P

E

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 74

7GAE PROJECT NO.: 219122

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

FOR CONSTRUCTION

100% BID DOCUMENTS

35% SCHEMATIC DESIGN 2019.11.14

65% DESIGN DEVELOPMENT 2020.01.04

95% DESIGN DEVELOPMENT 2020.08.07

100% BID DOCUMENTS 2021.04.01

COVER SHEET VAMC BC RENOVATE

COMMON AREAS, VARIOUS

BUILDINGS

5500 ARMSTRONG ROAD

BATTLE CREEK, MI 49037

515-20-101

N/A

PROJECT DIRECTOR

04 - 01 - 2021 JB JS

100% BID

DOCUMENTS

GI001

NOT APPLICABLE

BATTLE CREEK, MICHIGAN

NORTH

LOCATION MAPPROJECT TEAM DRAWING SHEET INDEX

ARCHITECTURE & ENGINEERING:

OWNER: DESCRIPTIONSHEET ISSUE DATE NOTES

PHONE: 269.927.0144

ALLIANCE | 7GAE JV

KALAMAZOO, MI 49007

600 E. MICHIGAN AVENUE - SUITE B

WEB: WWW.7GENAE.COM

DEPARTMENT OF VETERANS

AFFAIRS MEDICAL CENTER

BATTLE CREEK, MI 49037

5500 ARMSTRONG ROAD

PROJECT NO: 515-20-101: RENOVATE COMMON AREAS, VARIOUS BUILDINGS

BATTLE CREEK, MICHIGAN

DEPARTMENT OF VETERANS AFFAIRS

GI001 COVER SHEET 04 - 01 - 2021 GENERAL INFORMATION 01

GI002 GENERAL INFORMATION & SYMBOL LEGEND 04 - 01 - 2021 GENERAL INFORMATION 02

GC101 COMPOSITE PHASING PLAN 04 - 01 - 2021 PHASING 03

S001 STRUCTURAL GENERAL NOTES & DETAILS 04 - 01 - 2021 DETAILS 04

S002 FOUNDATION & FRAMING DETAILS 04 - 01 - 2021 DETAILS 05

AS100 SITE PLAN 04 - 01 - 2021 SITE 06

002.AD100 GROUND FLOOR DEMOLITION PLAN 04 - 01 - 2021 BUILDING 2 07

002.AD101 FIRST FLOOR DEMOLITION PLAN 04 - 01 - 2021 BUILDING 2 08

002.AD102 SECOND FLOOR DEMOLITION PLAN 04 - 01 - 2021 BUILDING 2 09

005.AD101 DEMOLITION PLAN & ELEVATION 04 - 01 - 2021 BUILDING 5 10

006.AD101 DEMOLITION PLANS & ELEVATION 04 - 01 - 2021 BUILDING 6 11

008.AD101 DEMOLITION FLOOR PLANS 04 - 01 - 2021 BUILDING 8 12

009.AD101 DEMOLITION FLOOR PLANS 04 - 01 - 2021 BUILDING 9 (DEDUCT ALTERNATE #3 - FIRST FLOOR) 13

010.AD101 DEMOLITION FLOOR PLANS 04 - 01 - 2021 BUILDING 10 14

011.AD101 DEMOLITION FLOOR PLAN 04 - 01 - 2021 BUILDING 11 (DEDUCT ALTERNATE #1) 15

012.AD101 DEMOLITION FLOOR PLANS 04 - 01 - 2021 BUILDING 12 (DEDUCT ALTERNATE #2 - SECOND FLOOR) 16

013.AD101 DEMOLITION PLANS & ELEVATION 04 - 01 - 2021 BUILDING 13 17

014.AD101 DEMOLITION PLAN & ELEVATION 04 - 01 - 2021 BUILDING 14 18

082.AD101 DEMOLITION PLANS & ELEVATION 04 - 01 - 2021 BUILDING 82 19

002.AE100 GROUND FLOOR PLAN 04 - 01 - 2021 BUILDING 2 20

002.AE101 FIRST FLOOR PLAN 04 - 01 - 2021 BUILDING 2 21

002.AE102 SECOND FLOOR PLAN 04 - 01 - 2021 BUILDING 2 22

005.AE101 PLANS & ELEVATION 04 - 01 - 2021 BUILDING 5 23

006.AE101 PLANS & ELEVATION 04 - 01 - 2021 BUILDING 6 24

008.AE101 FLOOR PLANS 04 - 01 - 2021 BUILDING 8 25

009.AE101 FLOOR PLANS 04 - 01 - 2021 BUILDING 9 (DEDUCT ALTERNATE #3 - FIRST FLOOR) 26

010.AE101 FIRST FLOOR PLAN 04 - 01 - 2021 BUILDING 10 27

011.AE101 FIRST FLOOR PLAN 04 - 01 - 2021 BUILDING 11 (DEDUCT ALTERNATE #1) 28

012.AE101 FLOOR PLANS 04 - 01 - 2021 BUILDING 12 (DEDUCT ALTERNATE #2 - SECOND FLOOR) 29

013.AE101 PLANS & ELEVATION 04 - 01 - 2021 BUILDING 13 30

014.AE101 PLANS & ELEVATION 04 - 01 - 2021 BUILDING 14 31

082.AE101 PLANS & ELEVATION 04 - 01 - 2021 BUILDING 82 32

AE300 BUILDING SECTIONS 04 - 01 - 2021 SECTIONS 33

AE320 EXTERIOR WALL SECTIONS 04 - 01 - 2021 SECTIONS 34

AE321 EXTERIOR WALL SECTIONS 04 - 01 - 2021 SECTIONS 35

AE340 INTERIOR WALL SECTIONS 04 - 01 - 2021 SECTIONS 36

AE341 INTERIOR WALL SECTIONS 04 - 01 - 2021 SECTIONS 37

AE342 INTERIOR WALL SECTIONS 04 - 01 - 2021 SECTIONS 38

AE343 INTERIOR WALL SECTIONS 04 - 01 - 2021 39

AE360 CEILING DETAILS 04 - 01 - 2021 DETAILS 40

AE600 DOOR SCHEDULE 04 - 01 - 2021 SCHEDULE 41

AE601 DOOR AND FRAME TYPES 04 - 01 - 2021 DETAILS 42

002.AC100 GROUND FLOOR CEILING PLAN 04 - 01 - 2021 BUILDING 2 43

002.AC101 FIRST FLOOR CEILING PLAN 04 - 01 - 2021 BUILDING 2 44

002.AC102 SECOND FLOOR CEILING PLAN 04 - 01 - 2021 BUILDING 2 45

006.AC.101 REFLECTED CEILING PLANS 04 - 01 - 2021 BUILDING 6 46

008.AC101 REFLECTED CEILING PLANS 04 - 01 - 2021 BUILDING 8 47

009.AC101 REFLECTED CEILING PLANS 04 - 01 - 2021 BUILDING 9 (DEDUCT ALTERNATE #3 - FIRST FLOOR) 48

010.AC101 REFLECTED CEILING PLANS 04 - 01 - 2021 BUILDING 10 49

011.AC101 REFLECTED CEILING PLAN 04 - 01 - 2021 BUILDING 11 (DEDUCT ALTERNATE #1) 50

012.AC101 REFLECTED CEILING PLANS 04 - 01 - 2021 BUILDING 12 (DEDUCT ALTERNATE #2 - SECOND FLOOR) 51

AI420 INTERIOR ELEVATIONS 04 - 01 - 2021 INTERIOR ELEVATIONS 52

AI421 INTERIOR ELEVATIONS 04 - 01 - 2021 INTERIOR ELEVATIONS 53

AI422 INTERIOR ELEVATIONS 04 - 01 - 2021 INTERIOR ELEVATIONS 54

AI423 INTERIOR ELEVATIONS 04 - 01 - 2021 INTERIOR ELEVATIONS 55

AI424 INTERIOR ELEVATIONS 04 - 01 - 2021 INTERIOR ELEVATIONS 56

AI425 INTERIOR ELEVATIONS 04 - 01 - 2021 INTERIOR ELEVATIONS 57

AI426 INTERIOR ELEVATIONS 04 - 01 - 2021 INTERIOR ELEVATIONS 58

AF100 INTERIOR FINISH KEY AND SCHEDULE 04 - 01 - 2021 SCHEDULE & DETAILS 59

AF200 SIGNAGE SCHEDULE 04 - 01 - 2021 SCHEDULE 60

AF201 SIGNAGE SCHEDULE 04 - 01 - 2021 SCHEDULE 61

002.AF100 GROUND FLOOR FINISH PLAN 04 - 01 - 2021 BUILDING 2 62

002.AF101 FIRST FLOOR FINISH PLAN 04 - 01 - 2021 BUILDING 2 63

002.AF102 SECOND FLOOR FINISH PLAN 04 - 01 - 2021 BUILDING 2 64

006.AF101 FIRST FLOOR FINISH PLAN 04 - 01 - 2021 BUILDING 6 65

008.AF101 FINISH PLANS 04 - 01 - 2021 BUILDING 8 66

009.AF101 FINISH PLANS 04 - 01 - 2021 BUILDING 9 (DEDUCT ALTERNATE #3 - FIRST FLOOR) 67

010.AF101 FIRST FLOOR FINISH PLAN 04 - 01 - 2021 BUILDING 10 68

011.AF101 FIRST FLOOR FINISH PLAN 04 - 01 - 2021 BUILDING 11 (DEDUCT ALTERNATE #1) 69

012.AF101 FINISH PLANS 04 - 01 - 2021 BUILDING 12 (DEDUCT ALTERNATE #2 - SECOND FLOOR) 70

082.AF101 FINISH PLAN 04 - 01 - 2021 BUILDING 82 71

PHONE: 202.617.8485

ALEXANDRIA, VA 22314

2850 EISENHOWER AVE - SUITE 310

WEB: WWW.ALLIANCE.US.COM

5500 ARMSTRONG ROAD

DIRECTOR

ASSOCIATE DIRECTOR

PROJECT #515-20-101 SIGNATURE DATE

CHIEF OF STAFF

CHIEF, FMS

CHIEF, ENGINEERING SECTION

CHIEF, ENVIRONMENTAL MANAGEMENT SECTION

INFECTION CONTROL MANAGER

PATIENT SAFETY MANAGER

GEMS COORDINATOR

CHIEF, POLICE SERVICE

CHIEF, FIRE SERVICE

UNION SAFETY REPRESENTATIVE

CONTRACTING OFFICER

COR

SAFETY SPECIALIST

ASSOCIATE DIRECTOR FOR PATIENT CARE SERVICES

DRAWING SEQUENCE #

E001 ELECTRICAL GENERAL INFORMATION & SYMBOL LEGEND AUGUST 07, 2020 SCHEDULE 72

002.E201 FIRST FLOOR POWER PLAN AUGUST 07, 2020 BUILDING 2 73

002.E101 FIRST FLOOR LIGHTING PLAN AUGUST 07, 2020 BUILDING 2 74

002.E102 LIGHTING FLOOR PLAN, VARIOUS BUILDINGS AUGUST 07, 2020 LIGHTING PLAN 75

Revisions: Date:

A300

A320

A420

A500

ARCHITECTURAL SYMBOLS & PLAN INDICATORS

ABBREVIATIONS

BARRIER-FREE DESIGN INFORMATION

ROOMNAME

XXX

A

A

A

A

8'-0"

TOP OF STEEL

ELEV. 10'-0"

A200

TITLE

SCALE X" = 1'-0"

OBSTRUCTED APPROACH

UNOBSTRUCTED APPROACH

DRINKING FOUNTAIN REQUIREMENTS

SCALE: NONE

TYP. CODE REGULATED MOUNTING HEIGHTS

SCALE: NONE

TYP. EQUIPMENT MOUNTING HEIGHTS

SCALE: NONE

ELEVATION INDICATION

SHEET NO.

ELEVATION NUMBER

SECTION INDICATOR

ENLARGED PLAN OR

ELEVATION

PROPOSED SPOT

EXISTING SPOT

ELEVATION

100.57'

100.57'

STRUCTURAL SPAN

ROOF TRUSSES

FLOOR JOIST OR

RAMP

@ 16" O.C.

2 x 12

1" per 12"

SLOPE UP

REVISION TAG W/

REVISION NUMBER

KEYNOTE TAG

WINDOW TAG W/

WINDOW TYPE

INDICATOR

WALL SECTION CUT

COLUMN LINE

WALL TYPES

ELEVATION

BUILDING SECTION CUT

SHEET LOCATION

DETAIL NUMBER

TYPICAL

DIMENSIONING

SET-BACK LINE

PROPERTY LINE

EXISTING

CONTOUR

TOPOGRAPHY

CONTOUR

100'

100'

TOPOGRAPHY

PROPOSED

SECTIONS & DETAILS

TYPICAL TITLE FOR

DOOR NUMBER

DOOR TAG W/

ROOM NUMBER

ROOM NAME/

NORTH ARROW

60" DIAMETER CLEAR

WHEELCHAIR TURNING

SPACE - REFER TO PLAN

- REFER TO PLAN

AND GROUND SPACE

30" x 48" CLEAR FLOOR

CEILING HEIGHT TAG

GENERAL NOTES:

ACCESSIBLE CONTROLS, OPERATING

MECHANISMS & HARDWARE SHALL COMPLY

WITH SECTIONS 1109.13 OF THE IBC AND

SECTION 309 OF ICC/ANSI A117.1.

ACCESSIBLE SIGNAGE FURNISHED BY OWNER,

SHALL COMPLY WITH SECTIONS 1110 OF THE

IBC AND SECTION 703 OF ICC/ANSI A117.1.

PORTABLE FIRE EXTINGUISHERS TO BE

PROVIDED IN ACCORDANCE WITH THE 2015

ICC INTERNATIONAL FIRE CODE. IBC (906.1).

REFER TO FLOOR PLAN SHEETS FOR

LOCATIONS OF FIRE EXTINGUISHER CABINETS

(FEC)

ELECTRIC WATER

COOLER

FRONT SIDE

RECEPTACLE

LIGHT

SWITCH

HVAC

CONTROLS

FIRE

ALARM

FEC

LESS THAN 40#

FEC

GREATER THAN 40#

TEL

PP

RH/CH

GBX

SH1

CL

OT

SPH

CRK SND

PT

SD

HS

XR COM4 MR

CRBG

WP

TP SNR

4'-4"

TV

MOUNTING HEIGHT GENERAL NOTES:

1. SEE OTHER SHEETS IN THIS SET FOR EQUIPMENT

ABBREVIATIONS AND LOCATIONS.

2. REFER TO INTERIOR ELEVATIONS FOR

ADDITIONAL INFORMATION.

3. ITEMS ON THIS SHEET ARE NOT NECESSARILY

INCLUDED IN THIS PROJECT.

4. CONTRACTOR TO VERIFY ALL EQUIPMENT

MOUNTING HEIGHTS WITH OWNER.

5. REFER TO ELECTRICAL DRAWINGS FOR

DEVICE MOUNTING HEIGHTS.

XXXNORTH

M A

X

M

IN

" 4

" 5

M A

X

TO

O

R

IF

IC

E

M

IN

6" MIN 11" MIN

8" MIN

TO

O

R

IF

IC

E

SIDE FRONT

M

A X

M

A X

20" - 25"

M

A X

FRONT

M

A X

20" MAX

SIDE

SIDE FRONT

M

IN

M

A X

M

IN

M

A X

@ AT

A/C AIR CONDITIONIN/AIR CONDITIONER

ACOUS ACOUSTICAL

AD AREA DRAIN, AUTOMATIC DAMPER

ADJ ADJUST, ADJUSTABLE

ALUM ALUMINUM

AP ACCESS PANEL

ACT ACOUSTICAL CEILING

ALT ALTERNATE

B BASE

BAR BARRIER

BD BOARD

BF BARRIER FREE

BG BUMPER GUARD

BKT BRACKET

BLDG BUILDING

BLKG BLOCKING

BOTT BOTTOM

C TO C CENTER TO CENTER

CAB CABINET

CE COLUMN ENCLOSURE

CH COAT HOOK

CIR CIRCLE

CIR CIRCUIT

CL CENTER LINE, CLEARANCES

CLG CEILING

CJ CONTROL JOINT

CLKG CAULKING

CLO CLOSET

CMT CERAMIC MOSAIC TILE

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

CONC CONCRETE

CONT CONTINUOUS

COR CONTRACTING OFFICER REPRESENTATIVE

VA COR CONTRACTING OFFICER REPRESENTATIVE

CORR CORRIDOR

CPT CARPET

CR CARD READER

CSS CLINICAL SERVICE SINK

CT CERAMIC TILE

CTR CENTER

CUH CABINET UNIT HEATER

DEMO DEMOLITION, DEMOLISH

DEDUCT DEDUCTIVE

DEPT DEPARTMENT

DF DRINKING FOUNTAIN

DIA, D DIAMETER

DIM DIMENSION

DN DOWN

DR DRAIN

DS DOWNSPOUT

ELECT ELECTRICAL

ELEV ELEVATION

ENTR ENTRANCE

EP ELECTRICAL PANEL

EQ EQUAL

ETP EXISTING TO BE PAINTED

ETR EXISTING TO REMAIN

EW EACH WAY

EXH EXHAUST

EXP EXPOSED

EXIST EXISTING, EXSIST'G

EXT EXTERIOR

FA FIRE ALARM

FD FIRE DAMPER OR FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FIN FINISH

FL, FLR FLOOR FINISH

FLG, FLRG FLOORING, FLOOR'G

FOUO FOR OFFICIAL USE ONLY

FURN FURNITURE, FURNACE

FWC FABRIC WALL COVERING

FT FEET, FOOT

GALV GALVANIZE(D)

GL GLASS

GSB GYPSUM SHEATHING BOARD

GWB GYPSUM WALLBOARD

GYP. BD GYPSUM BOARD

ID INSIDE DIAMETER

INSUL INSULATION

IN INCH(ES)

JAN JANITOR'S CLOSET

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HANDRAIL

HS HAND SANITIZER DISPENSER, WATERLESS

HT HEIGHT

HW HEADWALL

LAM LAMINATED

LF LINEAL FEET

MAS MASONRY

MAT'L MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MANUF MANUFACTURED, MANUFACTURER

MIN MINIMUM

MLD'G MOLDING

MTL METAL

MR MOP RACK

N NORTH

NAT NATURAL

NIC NOT IN CONTRACT

NORM NORMAL

NTS NOT TO SCALE

O.C. ON CENTER

O.H. OPPOSITE HAND

OPN'G OPENING

O, O2 OXYGEN

PLAST PLASTIC

PNT PAINT

PREFAB PREFABRICATED

PLYWD PLYWOOD, PLYW'D

R RADIUS

RA RETURN AIR

REQ'D REQUIRED

RH ROBE HOOK

RM ROOM

S SINK, SOUTH, SHINGLE

SA SUPPLY AIR

SAN SANITARY

SD SOAP DISPENSER

SMKD SMOKE DAMPER

SECT SECTION

SF SQUARE FOOT (FLOOR AREA)

SQ FT SQUARE FOOT

SHWR SHOWER

SIM SIMILAR

SPEC SPECIFICATION

SQ SQUARE

SS SERVICE SINK, STAINLESS STEEL

STD STANDARD

STOR STORAGE

SUSP SUSPEND(ED)

SYM SYMBOL, SYMMETRICAL

TOIL TOILET

TP TOILET PAPER DISPENSER

TYP TYPICAL

UNFIN UNFINISHED

UTIL UTILITY

VAC VACUUM

VAV VARIABLE AIR VOLUME

VCT VINYL COMPOSITION TILE

VD VOLUME DAMPER

VERT VERTICAL

V.I.F. VERIFY IN FIELD

VT VINYL TILE

VWC VINYL WALL COVERING

W/ WITH

WC WATER CLOSET

WD WOOD

WNDW WINDOW

W. HTR WATER HEATER

W/O WITHOUT

WP WALL PROTECTION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 74

7GAE PROJECT NO.: 219122

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

FOR CONSTRUCTION

100% BID DOCUMENTS

35% SCHEMATIC DESIGN 2019.11.14

65% DESIGN DEVELOPMENT 2020.01.04

95% DESIGN DEVELOPMENT 2020.08.07

100% BID DOCUMENTS 2021.04.01

GENERAL INFORMATION &

SYMBOL LEGEND

VAMC BC RENOVATE

COMMON AREAS, VARIOUS

BUILDINGS

5500 ARMSTRONG ROAD

BATTLE CREEK, MI 49037

515-20-101

N/A

PROJECT DIRECTOR

04 - 01 - 2021 JB JS

100% BID

DOCUMENTS

GI002

NOT APPLICABLE

STOR. FEMALE

OFFICE OFFICE SERVICE

RECORDS

OFFICE

OFFICE OFFICE

HSK

OFFICE

EXAM

STAFF LOUNGE/

I.T. OFFICE

MALE

WAITING ROOM

TRIAGE TRIAGE OFFICE

OFFICE

INFORMATION

RECEPTION

OFFICE

EXAM

EQUIP.

EXAM EXAM

RECORDS

OFFICE

MED

EXAM

OFFICE

HVAC

ELEV.

PIPE

CASHIER FUNDS

ELEV.

ELEV.

HVAC

PROSTHETICS

TREATMENT

STOR. WAITING

TREATMENT

OFFICETELE

DRESSING

ROOM

SOILED UTILITY

RECOVERY

CARE

STAFF

LOUNGE

NURSES

STATION

ELEC

CLOSET

TOILET

TOILET

MEN'S

WOMEN'S

STAIR

STAIR

STAIR

TOILET

ELEC.

ELEV.

OFFICEOFFICE

LOCKER ROOM

FEMALE

MALE

OFFICEOFFICE

OFFICE

AGENT PATIENT

PATIENT

SECURITY

CUSTOMER

ROOM

IMMEDIATE

ADMISSIONS

W.C. STOR.

OFFICE

ELEC.

STAIR

STOR.

MACH.

STAIRHSK

CLOSET

STOR.

00640067

S3

0074 0074A

0007 0005

0076 0077

0111 0112 0113 0114

S4

C012

E3

C013

0108 0116

C011

0117 0118 0119

C01

0103A

0050E

E

0014E

0006E

0004 0003

S1

0016A 0016 0017

0018E

C010

C06

C08

C09

S2

0092A

0122A

S5

0078A

0048A

0017A

E1 E2

C03A

C014

INSERTION

POINT

OFFICE SUITE

7,135 SQ. FT.

1109B

1171 1170

1109C

1109D

1184 1185

1169 1168 1167

S5 1206 1207 1208 1209

1191E

1192E

1102 1101 1100A

1203 12051204

1197 1198

1157A

S4

1149A1149C

1149B

1149D

1149F

S1

1117 1118

1120A

1156E

1133 1134

S2

1109A

1100C

1119E

1118A

1114 1124

1300D

1148A

1148B

1100B

E3

E1 E2

S3

E

1107E

C16C14

C13

C13A

E

E

1149E

TELEPH

TREATMENT

OFFICE

EXAM

FEMALE

OFFICE

STAIR

ROOM

TLT

ELEC

ELEV. ROOM

STOR

ROOM

CLERK

OFFICE

EXAM EXAM

TLT

EXAM

EXAM

MALE

BEDROOM

P.O.D.

ELEV. ELEV.

ELEV.

OFFICE

HSK

EXAM

EXAMEXAM

EXAM EXAM

TLT

OFFICE

OFFICE

OFFICE

OFFICE OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

WAITING

OFFICE

OFFICE OFFICE OFFICE OFFICE OFFICE

OFFICE

HSK

HVAC

EXAM

OFFICE

OFFICE

OFFICE OFFICE OFFICE OFFICE

OFFICEOFFICEOFFICE

OFFICEOFFICE TREATMENT

OFFICE

OFFICE OFFICE

EXAM

GROUP

TLT

WORK

GROUP

MECH AO

SPECIALITY

EXAM

STAIR

STAIR

OFFICE

OFFICE

OFFICE

OFFICEOFFICE

EQUIP.

STAIR

STAIR

HSK

HSK

WAITING

SERVICES

IT

ROOF OF TWO STORY ADDITION ROOF OF TWO STORY ADDITION

HOT LAB

ELEV.

MEDICINE

STORAGE

OFFICE

STOR.

CONF/BREAK

LOCKERS

OFFICE

OFFICE

LAB

CORR.

OFFICE

LABORATORY

MEN

LAB

WOMEN

STAIR

TESTING

STORAGE

CT EXAM

CT CONTROL

HSK

ELEV.

ROOM

LOUNGE

EXAMEXAM

MEN

HSK

WOMEN

LABORATORY

PROSTHETIC

DENTAL

SUPPLY

MED.

WOMEN'S

OFFICE

OFFICE

OFFICE

WAITING AREA

PHYS. OFF

X-RAY

STOR.

ROOM

CORRIDOR

ROOM

RECEPTIONSTOR.

WAITING

WAITING

STRESS

NUCLEAR

ELEV.

TLT

BLOOD

DRAW

TLT

ROOM RECEP.

WORK RECEPTION

OFFICE

HOT LAB

TLT

HSK

STAIR

TLT

EXAM

TLT

STAIR STAIR

LOCKERS

TREATMENT

ROOM

TREATMENT

ROOM

2271A

S3

C22

2208 2203A

S5

2202B

2222A

2224A

2225A 2237A

22632264A

2263A 2258

E

C25

2249A

S2

C22A

E3

E1 E2

2203A

2271B

S1

E

BUILDING: 2

157BUILDING: 11

BUILDING: 12

BUILDING: 14

BUILDING: 82

BUILDING: 5

BUILDING: 6

144 168

BUILDING: 13

BUILDING: 9

BUILDING: 10

BUILDING: 8

SHAFTER CIRCLE WEST

PAUL LAMBERS TR

AIL

DUANE DEWEY LANE

S H

A

FTE

R C

IR

C

LE

N

O R

TH

GOLF PARKING

URBAN D

RIV

E

A

F

SHAFTER C

IRC

LE SO

UTH D

G

D W

IG

H

T J O

H N

S O

N D

R

IV

E

S H

A F

TE

R C

IR

C

LE

E

A

ST

WIALLIAMS LANE

STEPHEN CHANDLER CT

H A

M M

ER

BE

R G

L A

N E

L K

H

EN

RY

F

O X

LA

N

E

FU

R

LO

N G

LA

N

E

C

R

FLO

RA

L LA

N

E

E

H

J

M

N

Q

B

A R

M S

TR

O N

G R

O A

D

-PHASE 10

-PHASE 8

-PHASE 7

-PHASE 10

-PHASE 10

-PHASE 5 AND 10

-PHASE 6

-PHASE 9

-PHASE 4

-PHASE 10

PROPOSED LAY-DOWN AREA;

REFER TO SITE PLAN LEGEND

PHASING LEGEND

PHASE 1

PHASE 2

PHASE 3

PHASE 4

PHASE 6

PHASE 7

PHASE 8

PHASE 9

PHASE 5 PHASE 10

GENERAL SEQUENCING NOTES

1. PHASING SHALL BE DONE IN SEQUENCE. NO PHASING

OVERLAP SHALL BE ALLOWED. NO WORK OUT OF

SEQUENCE SHALL BE ALLOWED.

2. ALL INTERIOR WORK COMMON AREA RENOVATIONS WORK

(PHASE 1 THRU PHAS 9) TO BE COMPLETED AFTER HOURS;

5:00 PM THROUGH 7:00 AM.

3. ANY WORK TO BE COMPLETED ABOVE NOISE LEVELS

INDICATED IN SPECIFICATIONS SHALL BE DONE AFTER

HOURS AND COORDINATED WITH THE CONTRACTING

OFFICER'S REPRESENTATIVE (COR) AT NO PREMIUM COST

TO THE GOVERNMENT.

4. PHASE 10 EXTERIOR CANOPY/VESTIBULE WORK CAN BE

COMPLETED AT CONTRACTOR'S DISCRETION WITH

COORDINATION AND APPROVAL OF THE CONTRACTING

OFFICER'S REPRESENTATIVE (COR).

5. PHASES TO BE COORDINATED WITH DEDUCTIVE ALTERNATES

AND COR.

6. COMPOSITE PHASING PLAN TO BE PRINTED IN COLOR ONLY.

DEDUCTIVE ALTERNATES

1. DEDUCTIVE ALTERNATE #1: BUILDING 11 - FIRST FLOOR

2. DEDUCTIVE ALTERNATE #2: BUILDING 11 - FIRST FLOOR, AND BUILDING 12 - SECOND FLOOR

3. DEDUCTIVE ALTERNATE #3: BUILDING 11 - FIRST FLOOR, AND BUILDING 12 - SECOND FLOOR, AND BUILDING 9 - FIRST FLOOR

SCALE: 1" = 100'-0"GC101

VA PROJECT PHASING PLAN01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 74

7GAE PROJECT NO.: 219122

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

FOR CONSTRUCTION

100% BID DOCUMENTS

35% SCHEMATIC DESIGN 2019.11.14

65% DESIGN DEVELOPMENT 2020.01.04

95% DESIGN DEVELOPMENT 2020.08.07

100% BID DOCUMENTS 2021.04.01

COMPOSITE PHASING PLAN VAMC BC RENOVATE

COMMON AREAS, VARIOUS

BUILDINGS

5500 ARMSTRONG ROAD

BATTLE CREEK, MI 49037

515-20-101

SITE

PROJECT DIRECTOR

04 - 01 - 2021 JB GN

100% BID

DOCUMENTS

GC101

NOT APPLICABLE

SCALE: 1" = 50'-0"GC101

B2: GROUND FLOOR PLAN - PHASE 1G

SCALE: 1" = 50'-0"GC101

B2: FIRST FLOOR PLAN - PHASE 21

SCALE: 1" = 50'-0"GC101

B2: SECOND FLOOR PLAN - PHASE 32

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 74

7GAE PROJECT NO.: 219122

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

FOR CONSTRUCTION

100% BID DOCUMENTS

35% SCHEMATIC DESIGN 2019.11.14

65% DESIGN DEVELOPMENT 2020.01.04

95% DESIGN DEVELOPMENT 2020.08.07

100% BID DOCUMENTS 2021.04.01

STRUCTURAL GENERAL NOTES

& DETAILS

VAMC BC RENOVATE

COMMON AREAS, VARIOUS

BUILDINGS

5500 ARMSTRONG ROAD

BATTLE CREEK, MI 49037

515-20-101

SITE

PROJECT DIRECTOR

04 - 01 - 2021 -- --

100% BID

DOCUMENTS

S001 04Revisions: Date:

OTHER BARS TOP BARS

CONCRETE COMPRESSIVE STRENGTH @ 28 DAYS = 3000 psi

AT CORNERS AT INTERSECTIONSSINGLE MAT

AT INTERSECTIONSAT CORNERS

ALL REINFORCING EXCEPT COLUMN TIES AND BEAM STIRRUPS

BEAM STIRRUPS AND COLUMN TIES

BEAM OR COLUMN CROSSTIES

STIRRUP STIRRUP OR TIE

LAP SPLICE & DEVELOPMENT LENGTH SCHEDULE

STANDARD HOOKS, BEND, STIRRUPS AND TIES

TYPICAL CORNER REINF AT CONCRETE FOOTINGS

TYPICAL CORNER REINF AT CONCRETE WALLS

TYPICAL SLAB ON GRADE CONTROL JOINT

SAW CUT JOINT

STRUCTURAL GENERAL

NOTES & DETAILS

VA BC RENOVATE COMMON

AREAS

5500 ARMSTRONG ROAD

BATTLE CREEK, MI 49037

515-20-101

PROJECT DIRECTOR

JANUARY 29, 2019 -- --

65% DESIGN

DEVELOPMENT

S001

P:\2019 Projects\219122 VA BC Renovate Common Areas\00_Drawings\06_Structural\219122VABC-RenovateCommonAreas_mhawarny@7genae-Alliance-SevenGenerations_JVLogo-Final-Revit-B&W-1858992.png

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PRELIMINARY

NOT FOR CONSTRUCTION DWG. ___ OF 40

7GAE PROJECT NO.: 219122

Sprinkler:

600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 74

7GAE PROJECT NO.: 219122

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

FOR CONSTRUCTION

100% BID DOCUMENTS

35% SCHEMATIC DESIGN 2019.11.14

65% DESIGN DEVELOPMENT 2020.01.04

95% DESIGN DEVELOPMENT 2020.08.07

100% BID DOCUMENTS 2021.04.01

FOUNDATION & FRAMING

DETAILS

VAMC BC RENOVATE

COMMON AREAS, VARIOUS

BUILDINGS

5500 ARMSTRONG ROAD

BATTLE CREEK, MI 49037

515-20-101

SITE

PROJECT DIRECTOR

04 - 01 - 2021 -- --

100% BID

DOCUMENTS

S002 05Revisions: Date:

FOUNDATION & ROOF FRAMING PLANS - BLDG 082

FOUNDATION PLAN ROOF FRAMING PLAN

FOUNDATION & ROOF FRAMING PLANS KEYED NOTES:

FOUNDATION & ROOF FRAMING PLANS - BLDG 013

FOUNDATION & ROOF FRAMING PLANS KEYED NOTES:

FOUNDATION PLAN ROOF FRAMING PLAN

FOUNDATION & ROOF FRAMING PLANS KEYED NOTES:

FOUNDATION & ROOF FRAMING PLANS - BLDG 014

FOUNDATION PLAN ROOF FRAMING PLAN

FOUNDATION PLAN ROOF FRAMING PLAN

FOUNDATION & ROOF FRAMING PLANS KEYED NOTES:

FOUNDATION & ROOF FRAMING PLANS - BLDG 005 AND BLDG 006

FOOTING DETAIL AT BLDG- 082

LATERAL STAIR SECTION AT BLDG- 005 & 006

TRANSVERSE STAIR SECTION AT BLDG- 005 & 006

HSS COLUMN TO CONCRETE CONNECTION

ROOF DETAIL AT BLDG - 082

TY

P

E -A

TY

P E

-B

TY

P

E -C

ROOF DETAIL AT BLDG - 082

ROOF DETAIL AT BLDG - 013

ROOF DETAIL AT BLDG - 013

ROOF DETAIL AT BLDG - 013

ROOF DETAIL AT BLDG - 005, 006 & 014

PLATE

LINE

PLATE

LINE

TYPICAL SADDLE AT BEAM - HSS COLUMN

SECTION

END CONDITION

TYPICAL PILASTER REINFORCEMENT

PLAN VIEW

ANGLE

RAFTER ATTACHMENT TO CONCRETE

P:\2019 Projects\219122 VA BC Renovate Common Areas\00_Drawings\06_Structural\219122VABC-RenovateCommonAreas_mhawarny@7genae-Alliance-SevenGenerations_JVLogo-Final-Revit-B&W-1858992.png

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PRELIMINARY

NOT FOR CONSTRUCTION DWG. ___ OF 40

7GAE PROJECT NO.: 219122

Sprinkler:

600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com

Revisions: Date:

FOUNDATION &

FRAMING DETAILS

VA BC RENOVATE COMMON

AREAS

5500 ARMSTRONG ROAD

BATTLE CREEK, MI 49037

515-20-101

PROJECT DIRECTOR

JANUARY 29, 2019 -- --

65% DESIGN

DEVELOPMENT

S002

BUILDING: 2

157BUILDING: 11

BUILDING: 12

BUILDING: 14

BUILDING: 82

BUILDING: 5

BUILDING: 6

144 168 BUILDING: 13

BUILDING: 9

BUILDING: 10

BUILDING: 8

SHAFTER CIRCLE WEST

PAUL LAMBERS TR

AIL

DUANE DEWEY LANE

S H

A

FTE

R C

IR

C

LE

N

O R

TH

GOLF PARKING

URBAN D

RIV

E

A

F

SHAFTER C

IRC

LE SO

UTH D

G

D W

IG

H

T J O

H N

S O

N D

R

IV

E

S H

A F

TE

R C

IR

C

LE

E

A

ST

WIALLIAMS LANE

STEPHEN CHANDLER CT

H A

M M

ER

BE

R G

L A

N E

L K

H

EN

RY

F

O X

LA

N

E

FU

R

LO

N G

LA

N

E

C

R

FLO

RA

L LA

N

E

E

H

J

M

N

Q

B

A R

M S

TR

O N

G R

O A

D

PROPOSED LAY-DOWN AREA;

REFER TO SITE PLAN LEGEND

9, 10

11,12

SITE PLAN LEGEND

NEW CANOPY / VESTIBULE

BUILDINGS WITH COMMON AREA RENOVATIONS

PROPOSED LAY-DOWN AREA AND DUMPSTER

LOCATION; COORDINATE EXACT LOCATION WITH

COR. AT COMPLETITON OF PROJECT ALL EXISTING

SURFACES (SCOPE IS NOT LIMITED TO THIS

HATCHED AREA) I.E. TURF, ASPHALT/CONCRETE

PAVING, ETC. CONTRACTOR DAMAGED DURING

THE FULL DURATION OF THIS PROJECT NEED TO BE

BROUGHT BACK TO BE REPAIRED ORIGINAL

CONDITION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 74

7GAE PROJECT NO.: 219122

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

FOR CONSTRUCTION

100% BID DOCUMENTS

35% SCHEMATIC DESIGN 2019.11.14

65% DESIGN DEVELOPMENT 2020.01.04

95% DESIGN DEVELOPMENT 2020.08.07

100% BID DOCUMENTS 2021.04.01

SITE PLAN VAMC BC RENOVATE

COMMON AREAS, VARIOUS

BUILDINGS

5500 ARMSTRONG ROAD

BATTLE CREEK, MI 49037

515-20-101

SITE

PROJECT DIRECTOR

04 - 01 - 2021 JB JS

100% BID

DOCUMENTS

AS100

NOT APPLICABLE

NORTH

SCALE: 1" = 100'-0"

VA CAMPUS SITE PLAN

STOR. FEMALE

OFFICE OFFICE SERVICE

RECORDS

OFFICE

OFFICE OFFICE

HSK

OFFICE

EXAM

STAFF LOUNGE/

I.T. OFFICE

MALE

WAITING ROOM

TRIAGE TRIAGE OFFICE

OFFICE

INFORMATION

RECEPTION

OFFICE

EXAM

EQUIP.

EXAM EXAM

RECORDS

OFFICE

MED

EXAM

OFFICE

HVAC

ELEV.

PIPE

CASHIER FUNDS

ELEV.

ELEV.

HVAC

PROSTHETICS

TREATMENT

STOR. WAITING

TREATMENT

OFFICETELE

DRESSING

ROOM

SOILED UTILITY

RECOVERY

CARE

STAFF

LOUNGE

NURSES

STATION

ELEC

CLOSET

TOILET

TOILET

MEN'S

WOMEN'S

STAIR

STAIR

STAIR

TOILET

ELEC.

ELEV.

OFFICEOFFICE

LOCKER ROOM

FEMALE

MALE

OFFICEOFFICE

OFFICE

AGENT PATIENT

PATIENT

SECURITY

CUSTOMER

ROOM

IMMEDIATE

ADMISSIONS

W.C. STOR.

OFFICE

ELEC.

STAIR

STOR.

MACH.

STAIRHSK

CLOSET

STOR.

00640067

S3

0074 0074A

0007 0005

0076 0077

0111 0112 0113 0114

S4

C012

E3

C013

0108 0116

C011

0117 0118 0119

C01

0103A

0050E

E

0014E

0006E

0004 0003

S1

0016A 0016 0017

0018E

C010

C06

C08

C09

S2

0092A

0122A

S5

0078A

0048A

0017A

E1 E2

C03A

C014

INSERTION

POINT

4B 6B 7A5A

5A 6B 7B

6A 7B5A360 SF

CORRIDOR

328 SF

CORRIDOR

186 SF

SUB WAITING

1 11

9A

THIS DOOR TO BE

REMOVED AND INFILLED

UNDER A SEPARATE

CONTRACT PRIOR TO THE

START OF THIS PROJECT

4A

5C

5C

5C

5C

5C

9B

7A

4A

5A 7B

7A

4A

5A

7B

4A

4A

4A

4A

4A4A

7A

7A

4A

4A

GENERAL DEMOLITION NOTES

1. ALL DEMOLITION WORK REQUIRED IS NOT NECESSARILY LIMITED

TO WHAT IS SHOWN ON THE DEMOLITION PLANS. THE INTENT IS

TO REMOVE ALL MATERIALS AND ITEMS AS REQUIRED TO

FACILITATE NEW CONSTRUCTION.

2. CONSTRUCTION AREAS TO BE COMPLETELY SEPARATED FROM

OCCUPIED AREAS WITH A ONE-HOUR FIRE RATED ASSEMBLY,

AND WITH SUITABLE DUST BARRIER. TEMPORARILY SEAL OFF ALL

RETURN & SUPPLY AIR DIFFUSERS IN CONSTRUCTION AREA.

PROVIDE RECIRCULATING HEPA FILTER IN CONSTRUCTION

AREA. ALL DEMOLISHED MATERIAL IS TO BE REMOVED FROM

SITE IN A COVERED CONTAINER. NEGATIVE AIR PRESSURE TO BE

MAINTAINED WITHIN CONSTRUCTION ZONE.

3. CONTRACTORS ARE TO VERIFY FIELD CONDITIONS INCLUDING

ABOVE CEILINGS BEFORE BIDDING, IF CONDITIONS DO NOT

REFLECT WHAT IS NOTED IN THE CONTRACT DOCUMENTS, THE

CONTRACTOR IS TO SUBMIT AN RFI.

4. BEFORE ANY WORK ON FIRE ALARM SYSTEM IS TO BE DONE

CONTRACTOR MUST COORDINATE WITH VA COR AND VA FIRE

SERVICE. ALL SMOKE AND HEAT DETECTORS SHALL BE COVERED

AND SEALED AGAINST DUST ENTRY DURING WORK AND

UNCOVERED AFTER WORK IS CONCLUDED, EACH DAY.

5. THIS PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET

OF CONSTRUCTION DOCUMENTS. DO NOT REMOVE ANY ITEMS

WITHOUT VERIFYING AND COORDINATING WITH ALL

CONSTRUCTION DOCUMENTS AND SPECIFICATIONS. ANY

DISCREPANCIES TO BE BROUGHT TO ARCHITECTS ATTENTION

BEFORE WORK IS TO BE DONE.

6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING DUMPSTERS.

LOCATION OF DUMPSTERS TO BE DETERMINED BY COR WITH

CONTRACTORS INPUT.

7. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL

DEMOLISHED MATERIALS. DO NOT ALLOW MATERIALS AND

DEBRIS GENERATED BY DEMOLITION ACTIVITIES TO

ACCUMULATE ON THE JOBSITE. REMOVE DAILY AND DISPOSE

OF IN A LEGAL MANNER. NO ONSITE SALE OR BURNING OF

REMOVED ITEMS IS PERMITTED.

8. THE CONTRACTOR MUST TAKE ALL NECESSARY PRECAUTIONS

TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKMEN ON

THE SITE TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON

ON, ABOUT OR ADJACENT TO THE PREMISES. THE CONTRACTOR

SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES AND

REGULATIONS PERTAINING TO SAFETY AND THE PREVENTION OF

ACCIDENTS.

9. THE CONTRACTOR MUST MAINTAIN ADEQUATE SUPPORT,

INSULATION, WATERPROOFING, EMERGENCY LIGHTING,

SECURITY, ALARMS, ETC. FOR ALL OR PART OF ITEMS WHICH

ARE TO REMAIN.

10. DO NOT CUT AND/OR PATCH STRUCTURAL ELEMENTS IN A

MANNER THAT COULD CHANGE THEIR LOAD-CARRYING

CAPACITY OR LOAD-DEFLECTION RATIO.

11. PATCH/REPAIR OR REPLACE ALL AREAS DAMAGED BY

DEMOLITION, REWORK AS REQUIRED, PREPARE FOR NEW

CONSTRUCTION AS REQUIRED. BRICK OR BLOCK PATCHING

SHALL BE TOOTHED-IN TO MATCH EXISTING COURSING PATTERN

WHERE EXPOSED.

12. REFER TO ASBESTOS SURVEY, AND IF ADDITIONAL HAZARDOUS

MATERIALS ARE ENCOUNTERED DURING DEMOLITION,

CONTRACTOR SHALL CONTACT COR FOR ABATEMENT.

13. REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND

SURFACES CUT OR DAMAGED DURING DEMOLITION, BY

METHODS AND WITH MATERIALS SO AS NOT TO VOID EXISTING

WARRANTIES.

14. CLEAN AREAS AND SPACES WHERE CUTTING AND PATCHING

ARE PERFORMED.

15. INTERIOR WALLS TO BE REMOVED, SHALL BE REMOVED THE

ENTIRE HEIGHT OF THE WALL UNLESS REQUIRED OTHERWISE BY

NEW OPENINGS IN EXISTING WALLS TO REMAIN.

16. CONTRACTOR SHALL PATCH, REPAIR, AND INFILL ALL APPLIED

FIREPROOFING MATERIAL IN AREAS LEFT UNPROTECTED DUE TO

REMOVAL OF EXISTING ELEMENTS OR AREAS DAMAGED

DURING NEW WORK AND DEMOLITION. MATCH EXISTING

FIREPROOFING MATERIAL TYPE AND THICKNESS TO MAINTAIN

REQUIRED LEVEL OR PROTECTION.

DEMOLITION KEY NOTES

REMOVE EXISTING DOOR & HARDWARE. EXISTING

FRAME TO REMAIN. PREPARE FRAME AS REQUIRED

TO RECEIVE NEW DOOR & HARDWARE. EXISTING

DOOR HARDWARE LOCKSETS, CORES, AND

KEYWAYS SHALL BE SALVAGED AND TURNED OVER

TO THE VA COR.

REMOVE EXISTING HARDWARE (DOOR TO REMAIN).

EXISTING DOOR HARDWARE LOCKSETS, CORES,

AND KEYWAYS SHALL BE SALVAGED AND TURNED

OVER TO THE VA COR.

REMOVE EXISTING WALL CAP; PARTIAL WALL TO

REMAIN

REMOVE EXISTING WALL-MOUNTED HANDRAILS

COMPLETE. SALVAGE CONNECTORS, MOUNTING

BRACKETS, AND END TERMINATIONS FOR RE-USE.

TURN BALANCE OVER TO COR UNLESS DIRECTED

OTHERWISE.

REMOVE EXISTING LOW WALL-MOUNTED BUMPER

GUARD COMPLETE. PATCH AND REPAIR WALL

SURFACE TO REMAIN.

REMOVE EXISTING WALL PROTECTION, WALL BASE,

AND ALL ITEMS ATTACHED TO THE WALLS (STORE

AND PROTECT FOR RE-INSTALLATION). PATCH &

REPAIR EXPOSED SURFACES TO REMAIN AS

REQUIRED FOR NEW CONSTRUCTION AND/OR NEW

FINISHES.

REMOVE EXISTING WALL COVERING/WALL PAPER,

WALL BASE AND ALL ITEMS ATTACHED TO THE WALLS

(STORE AND PROTECT FOR RE-INSTALLATION).

PATCH & REPAIR EXPOSED SURFACES TO REMAIN AS

REQUIRED FOR NEW CONSTRUCTION AND/OR NEW

FINISHES. ALL EXISTING ITEMS ATTACHED TO WALL,

SHALL BE STORED, AND WHERE DIRECTED BY COR

REINSTALLED.

REMOVE EXISTING CORNER GUARDS.

REMOVE EXISTING WOOD VENEER PANEL AND

BACKUP GYP BOARD. REFER TO DEMOLITION

SECTION.

REMOVE EXISTING WOOD VENEER PANEL; EXISTING

BACKUP MATERIAL TO REMAIN.

REMOVE EXISTING WINDOW SILL AND ASSOCIATED

WOOD TRIM; PATCH AND REPAIR WALL SURFACE TO

REMAIN.

REMOVE EXISTING CARPET FLOORING INCLUDING

ADHESIVES, NAILING STRIPS, TRANSITION STRIPS,

AND SETTING MATERIALS DOWN TO EXISTING

SUBSTRATE. GRIND CONCRETE FLOORS AS

REQUIRED TO PROVIDE A SMOOTH AND UNIFORM

SURFACE FOR NEW FINISHES.

REMOVE EXISTING VINYL COMPOSITION TILE/

LUXURY VINYL TILE FLOORING INCLUDING

ADHESIVES, TRANSITION STRIPS, AND SETTING

MATERIALS DOWN TO EXISTING SUBSTRATE. GRIND

CONCRETE FLOORS AS REQUIRED TO PROVIDE A

SMOOTH AND UNIFORM SURFACE FOR NEW

FINISHES.

REMOVE EXISTING TILE FLOORING INCLUDING

TRANSITION STRIPS, AND TILE MORTAR BED DOWN

TO EXISTING SUBSTRATE. GRIND CONCRETE FLOOR

AS REQUIRED TO PROVIDE A SMOOTH AND

UNIFORM SURFACE FOR NEW FINISHES. PROVIDE

FLOOR LEVELER AS REQUIRED.

REMOVE EXISTING ACOUSTICAL CEILING TILE AND

GRID SYSTEM COMPLETE INCLUDING ASSOCIATED

HANGERS, METAL TEE GRID, AND EDGE ANGLES.

EXISTING CEILING MOUNTED LIGHT FIXTURES

(UNLESS NOTED IN CONJUNCTION W/ 7B),

SPEAKERS, CAMERAS, FIRE ALARMS, MECHANICAL

DEVICES, SMOKE DETECTORS, SENSORS, WIRELESS

ACCESS POINT, EXIT SIGNAGE, SAFETY MIRRORS,

ETC. TO BE TEMPORARILY SUPPORTED FOR

REINSTALLATION IN NEW CEILING FINISH; REFER TO

REFLECTED CEILING PLANS FOR EXISTING AND

REINSTALLED LOCATIONS. [NOTE: ITEMS SHALL NOT

BE TEMPORARILY OR PERMANENTLY SUSPENDED

FROM FIRE SUPPRESSION LINES]

REMOVE EXISTING LIGHT FIXTURES COMPLETE AND

RETURN TO COR. EXISTING CIRCUITING (EXTEND AS

REQUIRED)AND CONTROLS TO REMAIN FOR REUSE

WITH NEW LIGHTING. REFER TO NEW WORK

REFLECTED CEILING PLANS FOR EXISTING LIGHTS TO

BE REMOVED AND EXISTING LIGHTS TO REMAIN. ALL

REMAINING CEILING MOUNTED ITEMS TO BE

REINSTALLED AS CALLED OUT IN 7A.

REMOVE EXISTING DRYWALL CEILING AND SUPPORT

SYSTEM. PATCH & REPAIR EXPOSED SURFACES TO

REMAIN AS REQUIRED FOR NEW CONSTRUCTION

AND/OR NEW FINISHES.

REMOVE EXISTING CASEWORK UPPER AND LOWER.

SALVAGE EQUIPMENT & TURN OVER TO COR

UNLESS DIRECTED OTHERWISE. PATCH AND REPAIR

EXPOSED SURFACES TO REMAIN AS REQUIRED TO

RECEIVE NEW CONSTRUCTION AND FINISHES.

REMOVE EXISTING COUNTERTOP INCLUDING BACK/

SIDESPLASH AND ALL ASSOCIATED SUPPORT

BRACKETS AND FRAMING. SALVAGE EQUIPMENT &

TURN OVER TO COR UNLESS DIRECTED OTHERWISE.

PATCH AND REPAIR EXPOSED SURFACES TO REMAIN

AS REQUIRED TO RECEIVE NEW CONSTRUCTION

AND FINISHES.

REMOVE EXISTING PLUMBING FIXTURE COMPLETE.

EXISTING SANITARY, WATER, AND VENT PIPING TO

REMAIN; PATCH AND REPAIR WALL AS REQUIRED.

REMOVE EXISTING STAIRS SYSTEM (TREADS, RISERS,

HANDRAILS, SUPPORTS, GUARD RAILS, ETC.) REFER

TO STRUCTURAL DRAWINGS FOR INFILL OF FLOOR

OPENING.

REMOVE EXISTING STAIR GRIP TAPE INCLUDING ALL

ADHESIVES DOWN TO EXISTING SUBSTRATE. SAND

EXISTING WOOD TREADS AND LANDINGS AND

PROVIDE FLOOR LEVEL AS REQUIRED TO PROVIDE A

SMOOTH AND UNIFORM SURFACE FOR NEW

FINISHES. DEMO EXISTING WALL MOUNTED

HANDRAIL AND SUPPORT.

REMOVE EXISTING WOODEN ROOF SHEATHING

AND STEEL PLATE ICICLE PROTECTION; REMOVE ALL

EXISTING FRAMING EXCLUDING SUPPORT

COLUMNS.

REMOVE EXISTING ROOF & STRUCTURE INCLUDING

WALL MOUNT BRACKETS AND FLASHING. PATCH

AND REPAIR EXISTING BRICK AND MORTAR TO

REMAIN

REMOVE EXISTING SYSTEM FURNITURE AND DESK

STORE AND PROTECT FOR RE-INSTALLATION,

COORDINATE WITH COR.

REMOVE EXISTING TERRAZZO FLOORING AND

INTEGRAL WALL BASE. PATCH AND REPAIR FLOOR.

PROVIDE FLOOR LEVELER AS REQUIRED.

4A

5A

6A

7A

9A

4B

6B

5B

5C

5D

5F

EXISTING FULLY FINISHED SPACE THAT ALL WALL FINISHES,

CEILINGS, FLOORING, CASEWORK, PLUMBING FIXTURES,

CEILING MOUNTED LIGHT FIXTURES ARE TO BE REMOVED.

EXISTING WALL CONSTRUCTION AND COLUMNS ARE TO

REMAIN, UNLESS NOTED OTHERWISE. PREPARE ALL SURFACES

FOR NEW CONSTRUCTION. PROVIDE SKIM COAT ON ALL WALL

SURFACES TO A LEVEL 5 FINISH.

EXISTING INTERIOR SPACE NOT INCLUDED IN SCOPE

OF THIS PROJECT

9B

REMOVE EXISTING CONCRETE STEPS INCLUDING

FOUNDATIONS/FOOTINGS AND EXISTING HANDRAILS AND

BRACKETS; PATCH AND REPAIR EXISTING BRICK TO REMAIN,

REMOVE EXISTING WALL TILE AND BACKING; PATCH AND

REPAIR WALL IN PREPARATION FOR NEW FINISHES.

SAWCUT AND REMOVE EXISTING CONCRETE UP TO EXISTING

CONTROL JOINT IN PREPARATION FOR NEW WORK.

REMOVE EXISTING WALL PARTITION (INCLUDING GLASS

SIDELIGHTS) FULL HEIGHT; PATCH AND REPAIR ADJOINING

FLOOR, WALL AND CEILING SURFACES TO REMAIN.

REMOVE EXISTING EXTERIOR STOREFRONT SYSTEM INCLUDING

DOOR. PATCH AND REPAIR ADJACENT WALL CONSTRUCTION

TO REMAIN.

REMOVE EXISTING FLOOR EXPANSION JOINT; EXISTING WALL

EXPANSION TO REMAIN.

REMOVE EXISTING FIRE EXTINGUISHER AND BRACKET SALVAGE

AND TURN OVER TO THE VA COR.

REMOVE EXISTING KIOSKS AND STORE FOR REINSTALLATION.

TURN BALANCE OVER TO COR.

REMOVE EXISTING DOOR, DOOR FRAME & HARDWARE.

PREPARE OPENING AS REQUIRED TO RECEIVE NEW DOOR &

HARDWARE. EXISTING DOOR HARDWARE LOCKSETS, CORES,

AND KEYWAYS SHALL BE SALVAGED AND TURNED OVER TO THE

VA COR.

5E

7B

6C

HAZARDOUS DEMO KEY NOTES

H1 ABATE AND REMOVE EXISTING DOOR LEAF WITH

ASBESTOS. EXISTING FRAME TO REMAIN.PREPARE

FRAME AS REQUIRED TO RECEIVE NEW DOOR &

HARDWARE.

ABATE AND REMOVE EXISTING ASBESTOS FLOOR TILE

AND ASBESTOS MASTIC. REMOVE EXISTING

ASBESTOS ADHESIVES, TRANSITION STRIPS. GRIND

EXISTING FLOOR SUBSTRATE TO A SMOOTH AND

UNIFORM SURFACE FOR NEW FINISHES. PATCH AND

REPAIR AS REQUIRED.

ABATE AND REMOVE EXISTING ASBESTOS FLOOR TILE

AND ASBESTOS BEDDING COMPOUND. REMOVE

EXISTING TRANSITION STRIPS, AND GRIND EXISTING

CONCRETE SUBSTRATE TO A SMOOTH AND

UNIFORM SURFACE FOR NEW FINISHES.

ABATE AND REMOVE EXISTING WALL TILE AND

ASBESTOS BEDDING COMPOUND. PATCH AND

REPAIR EXISTING/ADJACENT WALL TO REMAIN IN

PREPERATION FOR NEW WORK.

H2

H3

H4

BUILDING 2 ADDITIONAL

DEMOLITION NOTES

17. INFECTION CONTROL PERMIT WILL BE REQUIRED.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 74

7GAE PROJECT NO.: 219122

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

FOR CONSTRUCTION

100% BID DOCUMENTS

35% SCHEMATIC DESIGN 2019.11.14

65% DESIGN DEVELOPMENT 2020.01.04

95% DESIGN DEVELOPMENT 2020.08.07

100% BID DOCUMENTS 2021.04.01

GROUND FLOOR

DEMOLITION PLAN

VAMC BC RENOVATE

COMMON AREAS, VARIOUS

BUILDINGS

5500 ARMSTRONG ROAD

BATTLE CREEK, MI 49037

515-20-101

PROJECT DIRECTOR

04 - 01 - 2021 JB JS

100% BID

DOCUMENTS

002.AD100

PARTIALLY

SPRINKLED

SCALE: 1/8" = 1'-0"002.AD100

BUILDING 2: GROUND FLOOR DEMOLITION PLAN01

PLAN NORTH

OFFICE SUITE

7,135 SQ. FT.

1109B

1171 1170

1109C

1109D

1184 1185

1169 1168 1167

S5 1206 1207 1208 1209

1191E

1192E

1102 1101 1100A

1203 12051204

1197 1198

1157A

S4

1149A1149C

1149B

1149D

1149F

S1

1117 1118

1120A

1156E

1133 1134

S2

1109A

1100C

1119E

1118A

1114 1124

1300D

1148A

1148B

1100B

E3

E1 E2

S3

E

1107E

C16C14

C13

C13A

E

E

1149E

TELEPH

TREATMENT

OFFICE

EXAM

FEMALE

OFFICE

STAIR

ROOM

TLT

ELEC

ELEV. ROOM

STOR

ROOM

CLERK

OFFICE

EXAM EXAM

TLT

EXAM

EXAM

MALE

BEDROOM

P.O.D.

ELEV. ELEV.

ELEV.

OFFICE

HSK

EXAM

EXAMEXAM

EXAM EXAM

TLT

OFFICE

OFFICE

OFFICE

OFFICE OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

WAITING

OFFICE

OFFICE OFFICE OFFICE OFFICE OFFICE

OFFICE

HSK

HVAC

EXAM

OFFICE

OFFICE

OFFICE OFFICE OFFICE OFFICE

OFFICEOFFICEOFFICE

OFFICEOFFICE TREATMENT

OFFICE

OFFICE OFFICE

EXAM

GROUP

TLT

WORK

GROUP

MECH AO

SPECIALITY

EXAM

STAIRSTAIR

OFFICE

OFFICE

OFFICE

OFFICEOFFICE

EQUIP.

STAIR

STAIR

HSK

HSK

WAITING

SERVICES

IT

SDSD

SDSD

6B 7A5A

9B

9B

6A 7A5A

4A 6B 7A5A

4A 6B 7A5A

4A 6B 7A5A 4A 6B 7A5A

4A 6B 7A5A

4A 6B 7A5A

9A 9A

4A 6B 7A5A

4A 6B 7A5A

EXISTING COLUMN

COVER TO REMAIN

4A 6B 7A5A

4A 6B

7A

5A

551 SF

CORRIDOR

611 SF

CORRIDOR

144 SF

CORRIDOR

210 SF

ELEV. LOBBY

100 SF

019B

CORRIDOR

96 SF

019A

CORRIDOR

1151 SF

WAITING

373 SF

CORRIDOR

479 SF

CORRIDOR

74 SF

018B

CORRIDOR

99 SF

018A

CORRIDOR

221 SF

RECEPTION

1 1

H1

H1

11111

10 18

H1

1 1 1 1 1 1 1

1 1 1

1 1

4A 6B 7A5A

4A 6B 7A5A

5C 5C5C

5C

5C

5C

5C

5C5C5C5C

4A

5C

5C 5C

5C 5C 5C 5C 5C

AE340

AE340

AE340

5D

5D

5D

5D

5D

5F

5F

5F 5F 5F

5F

5F

5F

9B

9B

7B

REFER TO RCP

FOR LOCATION

7B

REFER TO RCP

FOR LOCATION

7B

7B

7B

DEMO EXISTING

BULKHEAD

EXISTING BULKHEAD

TO REMAIN

7B

7B

7B

7B

7B

7B

7B

GENERAL DEMOLITION NOTES

1. ALL DEMOLITION WORK REQUIRED IS NOT NECESSARILY LIMITED

TO WHAT IS SHOWN ON THE DEMOLITION PLANS. THE INTENT IS

TO REMOVE ALL MATERIALS AND ITEMS AS REQUIRED TO

FACILITATE NEW CONSTRUCTION.

2. CONSTRUCTION AREAS TO BE COMPLETELY SEPARATED FROM

OCCUPIED AREAS WITH A ONE-HOUR FIRE RATED ASSEMBLY,

AND WITH SUITABLE DUST BARRIER. TEMPORARILY SEAL OFF ALL

RETURN & SUPPLY AIR DIFFUSERS IN CONSTRUCTION AREA.

PROVIDE RECIRCULATING HEPA FILTER IN CONSTRUCTION

AREA. ALL DEMOLISHED MATERIAL IS TO BE REMOVED FROM

SITE IN A COVERED CONTAINER. NEGATIVE AIR PRESSURE TO BE

MAINTAINED WITHIN CONSTRUCTION ZONE.

3. CONTRACTORS ARE TO VERIFY FIELD CONDITIONS INCLUDING

ABOVE CEILINGS BEFORE BIDDING, IF CONDITIONS DO NOT

REFLECT WHAT IS NOTED IN THE CONTRACT DOCUMENTS, THE

CONTRACTOR IS TO SUBMIT AN RFI.

4. BEFORE ANY WORK ON FIRE ALARM SYSTEM IS TO BE DONE

CONTRACTOR MUST COORDINATE WITH VA COR AND VA FIRE

SERVICE. ALL SMOKE AND HEAT DETECTORS SHALL BE COVERED

AND SEALED AGAINST DUST ENTRY DURING WORK AND

UNCOVERED AFTER WORK IS CONCLUDED, EACH DAY.

5. THIS PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET

OF CONSTRUCTION DOCUMENTS. DO NOT REMOVE ANY ITEMS

WITHOUT VERIFYING AND COORDINATING WITH ALL

CONSTRUCTION DOCUMENTS AND SPECIFICATIONS. ANY

DISCREPANCIES TO BE BROUGHT TO ARCHITECTS ATTENTION

BEFORE WORK IS TO BE DONE.

6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING DUMPSTERS.

LOCATION OF DUMPSTERS TO BE DETERMINED BY COR WITH

CONTRACTORS INPUT.

7. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL

DEMOLISHED MATERIALS. DO NOT ALLOW MATERIALS AND

DEBRIS GENERATED BY DEMOLITION ACTIVITIES TO

ACCUMULATE ON THE JOBSITE. REMOVE DAILY AND DISPOSE

OF IN A LEGAL MANNER. NO ONSITE SALE OR BURNING OF

REMOVED ITEMS IS PERMITTED.

8. THE CONTRACTOR MUST TAKE ALL NECESSARY PRECAUTIONS

TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKMEN ON

THE SITE TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON

ON, ABOUT OR ADJACENT TO THE PREMISES. THE CONTRACTOR

SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES AND

REGULATIONS PERTAINING TO SAFETY AND THE PREVENTION OF

ACCIDENTS.

9. THE CONTRACTOR MUST MAINTAIN ADEQUATE SUPPORT,

INSULATION, WATERPROOFING, EMERGENCY LIGHTING,

SECURITY, ALARMS, ETC. FOR ALL OR PART OF ITEMS WHICH

ARE TO REMAIN.

10. DO NOT CUT AND/OR PATCH STRUCTURAL ELEMENTS IN A

MANNER THAT COULD CHANGE THEIR LOAD-CARRYING

CAPACITY OR LOAD-DEFLECTION RATIO.

11. PATCH/REPAIR OR REPLACE ALL AREAS DAMAGED BY

DEMOLITION, REWORK AS REQUIRED, PREPARE FOR NEW

CONSTRUCTION AS REQUIRED. BRICK OR BLOCK PATCHING

SHALL BE TOOTHED-IN TO MATCH EXISTING COURSING PATTERN

WHERE EXPOSED.

12. REFER TO ASBESTOS SURVEY, AND IF ADDITIONAL HAZARDOUS

MATERIALS ARE ENCOUNTERED DURING DEMOLITION,

CONTRACTOR SHALL CONTACT COR FOR ABATEMENT.

13. REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND

SURFACES CUT OR DAMAGED DURING DEMOLITION, BY

METHODS AND WITH MATERIALS SO AS NOT TO VOID EXISTING

WARRANTIES.

14. CLEAN AREAS AND SPACES WHERE CUTTING AND PATCHING

ARE PERFORMED.

15. INTERIOR WALLS TO BE REMOVED, SHALL BE REMOVED THE

ENTIRE HEIGHT OF THE WALL UNLESS REQUIRED OTHERWISE BY

NEW OPENINGS IN EXISTING WALLS TO REMAIN.

16. CONTRACTOR SHALL PATCH, REPAIR, AND INFILL ALL APPLIED

FIREPROOFING MATERIAL IN AREAS LEFT UNPROTECTED DUE TO

REMOVAL OF EXISTING ELEMENTS OR AREAS DAMAGED

DURING NEW WORK AND DEMOLITION. MATCH EXISTING

FIREPROOFING MATERIAL TYPE AND THICKNESS TO MAINTAIN

REQUIRED LEVEL OR PROTECTION.

DEMOLITION KEY NOTES

REMOVE EXISTING DOOR & HARDWARE. EXISTING

FRAME TO REMAIN. PREPARE FRAME AS REQUIRED

TO RECEIVE NEW DOOR & HARDWARE. EXISTING

DOOR HARDWARE LOCKSETS, CORES, AND

KEYWAYS SHALL BE SALVAGED AND TURNED OVER

TO THE VA COR.

REMOVE EXISTING HARDWARE (DOOR TO REMAIN).

EXISTING DOOR HARDWARE LOCKSETS, CORES,

AND KEYWAYS SHALL BE SALVAGED AND TURNED

OVER TO THE VA COR.

REMOVE EXISTING WALL CAP; PARTIAL WALL TO

REMAIN

REMOVE EXISTING WALL-MOUNTED HANDRAILS

COMPLETE. SALVAGE CONNECTORS, MOUNTING

BRACKETS, AND END TERMINATIONS FOR RE-USE.

TURN BALANCE OVER TO COR UNLESS DIRECTED

OTHERWISE.

REMOVE EXISTING LOW WALL-MOUNTED BUMPER

GUARD COMPLETE. PATCH AND REPAIR WALL

SURFACE TO REMAIN.

REMOVE EXISTING WALL PROTECTION, WALL BASE,

AND ALL ITEMS ATTACHED TO THE WALLS (STORE

AND PROTECT FOR RE-INSTALLATION). PATCH &

REPAIR EXPOSED SURFACES TO REMAIN AS

REQUIRED FOR NEW CONSTRUCTION AND/OR NEW

FINISHES.

REMOVE EXISTING WALL COVERING/WALL PAPER,

WALL BASE AND ALL ITEMS ATTACHED TO THE WALLS

(STORE AND PROTECT FOR RE-INSTALLATION).

PATCH & REPAIR EXPOSED SURFACES TO REMAIN AS

REQUIRED FOR NEW CONSTRUCTION AND/OR NEW

FINISHES. ALL EXISTING ITEMS ATTACHED TO WALL,

SHALL BE STORED, AND WHERE DIRECTED BY COR

REINSTALLED.

REMOVE EXISTING CORNER GUARDS.

REMOVE EXISTING WOOD VENEER PANEL AND

BACKUP GYP BOARD. REFER TO DEMOLITION

SECTION.

REMOVE EXISTING WOOD VENEER PANEL; EXISTING

BACKUP MATERIAL TO REMAIN.

REMOVE EXISTING WINDOW SILL AND ASSOCIATED

WOOD TRIM; PATCH AND REPAIR WALL SURFACE TO

REMAIN.

REMOVE EXISTING CARPET FLOORING INCLUDING

ADHESIVES, NAILING STRIPS, TRANSITION STRIPS,

AND SETTING MATERIALS DOWN TO EXISTING

SUBSTRATE. GRIND CONCRETE FLOORS AS

REQUIRED TO PROVIDE A SMOOTH AND UNIFORM

SURFACE FOR NEW FINISHES.

REMOVE EXISTING VINYL COMPOSITION TILE/

LUXURY VINYL TILE FLOORING INCLUDING

ADHESIVES, TRANSITION STRIPS, AND SETTING

MATERIALS DOWN TO EXISTING SUBSTRATE. GRIND

CONCRETE FLOORS AS REQUIRED TO PROVIDE A

SMOOTH AND UNIFORM SURFACE FOR NEW

FINISHES.

REMOVE EXISTING TILE FLOORING INCLUDING

TRANSITION STRIPS, AND TILE MORTAR BED DOWN

TO EXISTING SUBSTRATE. GRIND CONCRETE FLOOR

AS REQUIRED TO PROVIDE A SMOOTH AND

UNIFORM SURFACE FOR NEW FINISHES. PROVIDE

FLOOR LEVELER AS REQUIRED.

REMOVE EXISTING ACOUSTICAL CEILING TILE AND

GRID SYSTEM COMPLETE INCLUDING ASSOCIATED

HANGERS, METAL TEE GRID, AND EDGE ANGLES.

EXISTING CEILING MOUNTED LIGHT FIXTURES

(UNLESS NOTED IN CONJUNCTION W/ 7B),

SPEAKERS, CAMERAS, FIRE ALARMS, MECHANICAL

DEVICES, SMOKE DETECTORS, SENSORS, WIRELESS

ACCESS POINT, EXIT SIGNAGE, SAFETY MIRRORS,

ETC. TO BE TEMPORARILY SUPPORTED FOR

REINSTALLATION IN NEW CEILING FINISH; REFER TO

REFLECTED CEILING PLANS FOR EXISTING AND

REINSTALLED LOCATIONS. [NOTE: ITEMS SHALL NOT

BE TEMPORARILY OR PERMANENTLY SUSPENDED

FROM FIRE SUPPRESSION LINES]

REMOVE EXISTING LIGHT FIXTURES COMPLETE AND

RETURN TO COR. EXISTING CIRCUITING (EXTEND AS

REQUIRED)AND CONTROLS TO REMAIN FOR REUSE

WITH NEW LIGHTING. REFER TO NEW WORK

REFLECTED CEILING PLANS FOR EXISTING LIGHTS TO

BE REMOVED AND EXISTING LIGHTS TO REMAIN. ALL

REMAINING CEILING MOUNTED ITEMS TO BE

REINSTALLED AS CALLED OUT IN 7A.

REMOVE EXISTING DRYWALL CEILING AND SUPPORT

SYSTEM. PATCH & REPAIR EXPOSED SURFACES TO

REMAIN AS REQUIRED FOR NEW CONSTRUCTION

AND/OR NEW FINISHES.

REMOVE EXISTING CASEWORK UPPER AND LOWER.

SALVAGE EQUIPMENT & TURN OVER TO COR

UNLESS DIRECTED OTHERWISE. PATCH AND REPAIR

EXPOSED SURFACES TO REMAIN AS REQUIRED TO

RECEIVE NEW CONSTRUCTION AND FINISHES.

REMOVE EXISTING COUNTERTOP INCLUDING BACK/

SIDESPLASH AND ALL ASSOCIATED SUPPORT

BRACKETS AND FRAMING. SALVAGE EQUIPMENT &

TURN OVER TO COR UNLESS DIRECTED OTHERWISE.

PATCH AND REPAIR EXPOSED SURFACES TO REMAIN

AS REQUIRED TO RECEIVE NEW CONSTRUCTION

AND FINISHES.

REMOVE EXISTING PLUMBING FIXTURE COMPLETE.

EXISTING SANITARY, WATER, AND VENT PIPING TO

REMAIN; PATCH AND REPAIR WALL AS REQUIRED.

REMOVE EXISTING STAIRS SYSTEM (TREADS, RISERS,

HANDRAILS, SUPPORTS, GUARD RAILS, ETC.) REFER

TO STRUCTURAL DRAWINGS FOR INFILL OF FLOOR

OPENING.

REMOVE EXISTING STAIR GRIP TAPE INCLUDING ALL

ADHESIVES DOWN TO EXISTING SUBSTRATE. SAND

EXISTING WOOD TREADS AND LANDINGS AND

PROVIDE FLOOR LEVEL AS REQUIRED TO PROVIDE A

SMOOTH AND UNIFORM SURFACE FOR NEW

FINISHES. DEMO EXISTING WALL MOUNTED

HANDRAIL AND SUPPORT.

REMOVE EXISTING WOODEN ROOF SHEATHING

AND STEEL PLATE ICICLE PROTECTION; REMOVE ALL

EXISTING FRAMING EXCLUDING SUPPORT

COLUMNS.

REMOVE EXISTING ROOF & STRUCTURE INCLUDING

WALL MOUNT BRACKETS AND FLASHING. PATCH

AND REPAIR EXISTING BRICK AND MORTAR TO

REMAIN

REMOVE EXISTING SYSTEM FURNITURE AND DESK

STORE AND PROTECT FOR RE-INSTALLATION,

COORDINATE WITH COR.

REMOVE EXISTING TERRAZZO FLOORING AND

INTEGRAL WALL BASE. PATCH AND REPAIR FLOOR.

PROVIDE FLOOR LEVELER AS REQUIRED.

4A

5A

6A

7A

9A

4B

6B

5B

5C

5D

5F

EXISTING FULLY FINISHED SPACE THAT ALL WALL FINISHES,

CEILINGS, FLOORING, CASEWORK, PLUMBING FIXTURES,

CEILING MOUNTED LIGHT FIXTURES ARE TO BE REMOVED.

EXISTING WALL CONSTRUCTION AND COLUMNS ARE TO

REMAIN, UNLESS NOTED OTHERWISE. PREPARE ALL SURFACES

FOR NEW CONSTRUCTION. PROVIDE SKIM COAT ON ALL WALL

SURFACES TO A LEVEL 5 FINISH.

EXISTING INTERIOR SPACE NOT INCLUDED IN SCOPE

OF THIS PROJECT

9B

REMOVE EXISTING CONCRETE STEPS INCLUDING

FOUNDATIONS/FOOTINGS AND EXISTING HANDRAILS AND

BRACKETS; PATCH AND REPAIR EXISTING BRICK TO REMAIN,

REMOVE EXISTING WALL TILE AND BACKING; PATCH AND

REPAIR WALL IN PREPARATION FOR NEW FINISHES.

SAWCUT AND REMOVE EXISTING CONCRETE UP TO EXISTING

CONTROL JOINT IN PREPARATION FOR NEW WORK.

REMOVE EXISTING WALL PARTITION (INCLUDING GLASS

SIDELIGHTS) FULL HEIGHT; PATCH AND REPAIR ADJOINING

FLOOR, WALL AND CEILING SURFACES TO REMAIN.

REMOVE EXISTING EXTERIOR STOREFRONT SYSTEM INCLUDING

DOOR. PATCH AND REPAIR ADJACENT WALL CONSTRUCTION

TO REMAIN.

REMOVE EXISTING FLOOR EXPANSION JOINT; EXISTING WALL

EXPANSION TO REMAIN.

REMOVE EXISTING FIRE EXTINGUISHER AND BRACKET SALVAGE

AND TURN OVER TO THE VA COR.

REMOVE EXISTING KIOSKS AND STORE FOR REINSTALLATION.

TURN BALANCE OVER TO COR.

REMOVE EXISTING DOOR, DOOR FRAME & HARDWARE.

PREPARE OPENING AS REQUIRED TO RECEIVE NEW DOOR &

HARDWARE. EXISTING DOOR HARDWARE LOCKSETS, CORES,

AND KEYWAYS SHALL BE SALVAGED AND TURNED OVER TO THE

VA COR.

5E

7B

6C

HAZARDOUS DEMO KEY NOTES

H1 ABATE AND REMOVE EXISTING DOOR LEAF WITH

ASBESTOS. EXISTING FRAME TO REMAIN.PREPARE

FRAME AS REQUIRED TO RECEIVE NEW DOOR &

HARDWARE.

ABATE AND REMOVE EXISTING ASBESTOS FLOOR TILE

AND ASBESTOS MASTIC. REMOVE EXISTING

ASBESTOS ADHESIVES, TRANSITION STRIPS. GRIND

EXISTING FLOOR SUBSTRATE TO A SMOOTH AND

UNIFORM SURFACE FOR NEW FINISHES. PATCH AND

REPAIR AS REQUIRED.

ABATE AND REMOVE EXISTING ASBESTOS FLOOR TILE

AND ASBESTOS BEDDING COMPOUND. REMOVE

EXISTING TRANSITION STRIPS, AND GRIND EXISTING

CONCRETE SUBSTRATE TO A SMOOTH AND

UNIFORM SURFACE FOR NEW FINISHES.

ABATE AND REMOVE EXISTING WALL TILE AND

ASBESTOS BEDDING COMPOUND. PATCH AND

REPAIR EXISTING/ADJACENT WALL TO REMAIN IN

PREPERATION FOR NEW WORK.

H2

H3

H4

BUILDING 2 ADDITIONAL

DEMOLITION NOTES

17. INFECTION CONTROL PERMIT WILL BE REQUIRED.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 74

7GAE PROJECT NO.: 219122

Sprinkler:

600 E. Michigan Avenue, Suite B

Kalamazoo, MI 49007

P: 269.927.0144 www.7GenAE.com

2850 Eisenhower Ave, Suite 310

Alexandria, VA 22314

P: 202.617.8485 www.alliance.us.com

FOR CONSTRUCTION

100% BID DOCUMENTS

35% SCHEMATIC DESIGN 2019.11.14

65% DESIGN DEVELOPMENT 2020.01.04

95% DESIGN DEVELOPMENT 2020.08.07

100% BID DOCUMENTS 2021.04.01

FIRST FLOOR DEMOLITION

PLAN

VAMC BC RENOVATE

COMMON AREAS, VARIOUS

BUILDINGS

5500 ARMSTRONG ROAD

BATTLE CREEK, MI 49037

515-20-101

PROJECT DIRECTOR

04 - 01 - 2021 JB JS

100% BID

DOCUMENTS

002.AD101

PARTIALLY

SPRINKLED

SCALE: 1/8" = 1'-0"002.AD101

BUILDING 2: FIRST FLOOR DEMOLITION PLAN01

ROOF OF TWO STORY ADDITION ROOF OF TWO STORY ADDITION

HOT LAB

ELEV.

MEDICINE

STORAGE

OFFICE

STOR.

CONF/BREAK

LOCKERS

OFFICE

OFFICE

LAB

CORR.

OFFICE

LABORATORY

MEN

LAB

WOMEN

STAIR

TESTING

STORAGE

CT EXAM

CT CONTROL

HSK

ELEV.

ROOM

LOUNGE

EXAMEXAMWAITING

MEN

HSK

WOMEN

LABORATORY

PROSTHETIC

DENTAL

SUPPLY

MED.

WOMEN'S

OFFICE

OFFICE

OFFICE

WAITING AREA

PHYS. OFF

X-RAY

STOR.

ROOM

CORRIDOR

ROOM

RECEPTIONSTOR.

WAITING

WAITING

STRESS

NUCLEAR

ELEV.

TLT

BLOOD

DRAW

TLT

ROOM RECEP.

WORK RECEPTION

OFFICE

HOT LAB

TLT

HSK

STAIR

TLT

EXAM

TLT

STAIR STAIR

LOCKERS

TREATMENT

ROOM

TREATMENT

ROOM

2271A

S3

C22

2208 2203A

S5

2202B

2222A

2224A

2225A 2237A

2264 2264A

2263A 2258

E

C25

2249A

S2

C22A

E3

E1 E2

2203A

2271B

S1

E

4A 6B 7A5A 6B

4A

6A 7A5A

4A 6B 7A5A

6B 7A5A

H1 1

H1

1 1 1

H1

352 SF

CORRIDOR

396 SF

WAITING ROOM

1013 SF

CORRIDOR

6A 7A5B

4A

AE340

AE340

5C

5C

5C

5C

5C 5C

EXISTING COILING

WINDOW TO BE REMOVED

AND RE-INSTALLED

AE341

4A 6B 7A5A9B5D5B

5F 5D

5D 9B

7B

7B 7B

REFER TO RCP

FOR LOCATION

REFER TO RCP

FOR LOCATION

REFER TO RCP

FOR LOCATION

7B

7B

7B

5C

181 SF

WAITING ROOM

DEMOLITION KEY NOTES

REMOVE EXISTING DOOR & HARDWARE. EXISTING

FRAME TO REMAIN. PREPARE FRAME AS REQUIRED

TO RECEIVE NEW DOOR & HARDWARE. EXISTING

DOOR HARDWARE LOCKSETS, CORES, AND

KEYWAYS SHALL BE…