DRAFT8457_E3.pdf
PDF 193 KB Posted
- Attached to
- Fort Leonard Wood MATOC IDIQ
- Solicitation number
- W911S7-23-R-0001
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C O
F F
E
S
T A
T I O
N
SCALE:
D E
S I G
N E
D
C H
E C
K E
D
S U
B M
I T
T E
D
A P
P R
O V
E D
D A
T E
R E
V I S
I O
N S
D I R
E C
T O
R A
F
P
U B
L I C
W
R
K S
F O
R
L
O
N A
R D
W
O
D
M
I S
S O
U R
I
D R
A W
N
DATE:
PROJECT NO:
DRAWING NO:
SHEET OF
D A
T E
M A
D E
A P
P R
O V
E D
J
B a l e s
C
E
D B
A
L O
P E
Z
A
L O
P E
Z
J
B
A L E
S
A
L O
P E
Z
P O
W E
R
L A
Y O
U
N
K I T
C H
E N
B L
G
R E
N O
V A
K
T
C H
N
A
B U
I L
D I N
G
AS SHOWN
07DEC22
M.0118951
FES 08369-1J
8457.12
E3 3
N
E3
1'-5"
PLAN NORTH
LAYOUT OF POWER AND FIRE ALARM SYSTEM IN THE KITCHEN, BLDG.580
NOT TO SCALE
G
G
G
G
GG
LEGEND
GG
G
20A /120 VOLT DUPLEX GFCI ABOVE
THE COUNTER
20A /120 VOLT DUPLEX RECEPTACLES
UNDER THE COUNTER
G
40 A/
240 VOLTS
G 40A
40A /240 VOLT DUPLEX RECEPTACLES
FOR THE COOKING RANGE
1.THE CONTRACTOR SHALL DEMO ALL THE APPLIANCES AS SHOWN IN THE DRAWING.
2.TEMPORARILY THE CONTRACTOR SHALL RELOCATE THESE APPLIANCES TO DESIGNATED AREA
AND CONNECT TO THE PROPERLY RATED BREAKERS TO TAKE SUPPLY FROM THE ELECTRICAL PANEL IN THE
ELECTRICAL ROOM.
3. THE CONTRACTOR SHALL REMOVE COMPLETELY THE CABLES FROM THE ELECTRICAL PANELS AS WELL AS FROM
APPLIANCES OUTLETS OF THE KITCHEN.THESE CABLES ARE TO BE BLACK TAPPED AND MARKED THE CIRCUIT NOS.
THE CONTRACTOR SHALL PROVIDE NEW WIRING FOR THE TEMPORARY KITCHEN.BEFORE FINISHING THE CIVIL WORK THE
CONTRACTOR SHALL DRAW THE CABLES FOR THE MARKED UP CIRCUITS TO THE APPLIANCES OUTLETS UTILIZING THE
EXISTING CONDUITS AS LAID OUT IN THE NOTE NO.6 .
4. BEFORE START OF THE PROJECT WORK THE CONTRACTOR SHALL FOLLOW LOCK OUT AND TAG OUT PROCEDURES
FOR THE SAFETY OF PERSONNEL AND PROPERTIES
5. THE CONTRACTOR SHALL PROVIDE HEAT DETECTOR AS SHOWN IN THE DRAWING AS PER NFPA 72B AND MAKE PROGRAM
TEST INCLUDING INSULATION RESISTANCE TEST IN FRONT THE FIRE DEPARTMENT PERSONNEL.THE CONTRACTOR SHALL
TEST OF FIRE ALARM DEVICES 10% OF THE EXISTING ONES.THE WIRES FOR THE HEAT DETECTOR SHALL BE MINIMUM NO.16
AWG THWN COPPER.THE EXISTING ANSUL SYSTEM SHALL REMAIN TO EXIST.THE CONTRACTOR SHALL TEST THE ANSUL
SYSTEM IN PRESENCE OF THE FIRE DEPARTMENT PERSONNEL.
6. THE CONTRACTOR CAN USE EXISTING CONDUITS IF THESE ARE IN GOOD CONDITION AND PROVIDE THE FRESH WIRING
INSIDE THE KITCHEN AREA.ALL SPLICING OF THE WIRING SHALL BE IN STAINLESS STEEL JUNCTION BOX .THE SIZE OF THE
WIRING SHALL BE SAME AS THE EXISTING ONES.
7. MC CABLES IN GENERAL ARE NOT ALLOWED.BUT FOR THE LIGHT FIXTURES FROM JOINT BOX TO THE TERMINATION
IS ALLOWED FOR MAXIMUM 6 FT LENGTH.
8. THE EXISTING CIRCUITS FOR THE REFRIGERATORS ARE CKT. NO.2, 4 AND 8 FROM THE ELECTRICAL PANEL EP-S
IN THE ELECTRICAL ROOM
9. THE EXISTING CIRCUITS FOR THE MICROWAVES ARE CKT . NO.3 AND 5 FROM THE ELECTRICAL PANEL- KP.THE EXISTING
CIRCUIT FOR THE OVEN IS CKT NO.8 FROM THE THE PANEL -KP.THE EXISTING CIRCUITS FOR THE RECEPTACLES ARE
CKT. NO. 1,2 AND 6. SHALL BE FOR COFFEE, PANTRY AND FREE STANDING ISLAND AREA RESPECTIVELY.
10.THE EXISTING CIRCUIT FOR THE DISHWASHER IS CKT. NO.28 FROM THE ELECTRICAL PANEL-RM.THE EXHAUST FAN FOR
THE KITCHEN IS FROM THE CIRCUIT NO.36 OF ELECTRICAL PANEL-RP.THE EXISTING LIGHTING CIRCUIT FOR THE KITCHEN
IS CKT . NO.3 FROM ELECTRICAL PANEL-EP.
11.THE CONTRACTOR SHALL FIELD VERIFY THE CIRCUITS FOR LIGHT FIXTURES AND POWER SO THAT WHEN THEY START THE WORK
FOR TEMPORARY KITCHEN , THEY SHALL UTILIZE THE SAME CIRCUITS BEFORE RELOCATE TO THE RENOVATED KITCHEN.
1. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH NFPA 70 AND NFPA 101.
2. ELECTRICIANS SHALL MAINTAIN CONTINUITY OF CIRCUITS IN CASES WHERE IT FEEDS OTHER AREAS TO REMAIN IS
3. PROTECT THE STRUCTURE, FURNISHINGS,FINISHED AND ADJACENT MATERIALS NOT INDICATED OR SCHEDULED
TO BE REMOVED
4.CONCEALED BRANCH CIRCUITS SHALL CONSIST OF NO. 12THWN COPPER CONDUCTORS IN 1/2" EMT,UNO,SURFACE
MOUNTED BRANCH CIRCUITS SHALL CONSIST OF NO.12 AWG THWN COPPER CONDUCTORS IN IVORY COLORED
SURFACE METAL RACEWAY UNO
5. A GREEN JACKETED #12 AWG THWN GROUNDING CONDUCTOR SHALL BE INCLUDED IN ALL CIRCUITS EXCEPT WHERE
USE OF LARGER AWG SIZE IS SPECIFIED.
6.ALL WALL AND CEILING PENETRATIONS SHALL BE SEALED WITH A MATERIAL(PRINTABLE FIRE CAULK) CAPABLE OF
PREVENTING THE PASSAGE OF FLAMES AND HOT GASES.THE SEALANT SHALL HAVE A T-RATING OF ONE HOUR.
7.ALL PIPING, RACEWAYS AND OUTLET BOXES SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE
MATERIAL.
8.SOME RECEPTACLES,LIGHTS,SWITCHES,TELEPHONE/COMMUNICATION RECEPTACLES,CONDUIT,BOXES , FIRE ALARM
DEVICES AND CONNECTED WIRING WHICH ARE EXISTING TO BE REMOVED OR TO REMAIN MAY NOT BE SHOWN ON
THESE DRAWINGS AND SHALL BE FIELD VERIFIED.
9.BRANCH CIRCUITS,LIGHTING CIRCUITS AND COMMUNICATIONS CIRCUITS SHALL BE CONCEALED INSIDE FINISHED WALL
AND ABOVE CEILING, WHERE PRACTICABLE.WIRING DEVICES SHALL BE FLUSH MOUNTED WHERE PRACTICABLE.NO
WIRING SPLICES BE INACCESSIBLE.SURFACE METAL RACEWAY AND SURFACE MOUNTED WIRING DEVICES SHALL BE
UTILIZED WHERE FLUSH MOUNTING IS NOT PRACTICABLE.ALL SURFACE METAL RACEWAY(EXCEPT INDICATED
EXPOSED COMMUNICATION EMT CONDUIT SYSTEM,ABOVE CEILING AND IN COMMUNICATION EQUIPMENT ROOM)
SHALL BE IVORY COLOR.
10.ALL BRANCH CIRCUITS SHALL HAVE A DEDICATED NEUTRAL CONDUCTOR PROVIDED FOR EACH PHASE CONDUCTOR
11.BRANCH CIRCUITS ARE NOT SHOWN ON PLAN DRAWINGS AND SHALL BE FIELD VERIFIED.CIRCUIT PANEL AND CIRCUIT
NUMBERS AND KEEP UPDATE THE CIRCUIT LIST INSIDE THE PANELS.
12.CONTRACTOR MAY USE THE EXISTING CONDUITS IF THESE ARE IN GOOD CONDITION.DAMAGED AND RUSTED CONDUITS
ARE TO BE REMOVED. ALL EXISTING WIRES ARE TO BE USED.
13. THE CONTRACTOR SHALL UTILIZE THE EXISTING CIRCUIT NO. 4 FROM THE ELECTRICAL PANEL-KP FOR THE NEW
GARBAGE DISPOSAL.
14.THE CONTRACTOR SHALL UTILIZE THE EXISTING RECEPTACLES AND THE GFCIS IN THIS RENOVATION OF THE
KITCHEN WORK.
GENERAL NOTES
NOTES
H
H
CEILING MOUNT HEAT DETECTOR
MICROWAVES
G
DISHWASHER
GARBAGE
DISPOSAL
REFRIGERATOR REFRIGERATOR
REFRIGERATOR
19'-0"
(APPROX)
13'-5"
(APPROX)
U
U
UNO UNLESS NOTICED OTHERWISE
A$
A$
EXISTING ANSUL SWITCH TO BE
RELOCATED FROM PREVIOUS
LOCATION
ST
ST
EXISTING FIRE ALARM STROBE
LIGHT DEVICE TO BE
RELOCATED FROM THE ITS
PREVIOUS LOCATION