DRAFT8457_a1-DEMOLITION PLAN.pdf
PDF 195 KB Posted
- Attached to
- Fort Leonard Wood MATOC IDIQ
- Solicitation number
- W911S7-23-R-0001
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE:
D E
S I G
N E
D
C H
E C
K E
D
S U
B M
I T
T E
D
A P
P R
O V
E D
D A
T E
R E
V I S
I O
N S
D I R
E C
T O
R A
T E
O
F
P
U B
L I C
W
R
K S
F O
R
L
O
N A
R
W
O
D
M
I S
S O
U R
I
D R
A W
N
DATE:
PROJECT NO:
DRAWING NO:
SHEET OF
D A
T E
M A
D E
A P
P R
O V
E D
J
B a l e s
C
E
D B
A
L O
P E
Z
A
L O
P E
Z
J
B
A L E
S
A
L O
P E
Z
D E
M O
L I T
I O
N
P
L A
N
R E
N O
V A
K
I T
C H
N
A
B U
I L
D I N
G
AS SHOWN
07DEC22
M.0118951
FES 08369-1J
8457.12
A1 7
KITCHEN
N
DEMOLISH KITCHEN GYPSUM WALL BOARD, PORCELAIN FLOOR TILE AND BASE
DEMOLISH ALL WALL, BASE, AND TALL CABINETS
DEMOLISH COUNTERTOP AND BACKSPLASH
REMOVE COUNTERTOP, FINISHES AND GYPSUM BOARD ON HALF WALL.
REMOVE, REFURBISH, AND STORE TO REINSTALL RANGE - HOOD SHALL REMAIN
REMOVE, RELOCATE, CONNECT IN NEW LOCATION, AND REMOVE
TO CONNECT BACK IN KITCHEN AFTER REMODELING IS COMPLETED
REMOVE WALL COMPLETE EXCEPT AS INDICATED
DEMOLISH CHAIR RAIL
DEMOLISH WALL ABOVE COUNTERTOP AND LEAVE HALF WALL FRAME IN PLACE
REDUCED TO THE CABINET WIDTH
REMOVE SOFFIT ABOVE WALL CABINETS
DEMOLITION PLAN
A1
DEMOLITION KEYNOTES
DEMOLITION NOTES
DEMOLISH ACOUSTIC CEILING TILE SYSTEM AND FIXTURES WITHIN NEW
KITCHEN AREA ALL THE WAY TO WHERE FLOOR TILE CHANGES
REMOVE LIGHT FIXTURES UNDER WALL CABINETS
INDICATES HALF WALL FRAME TO REMAIN
LEGEND
INDICATES COMPLETE REMOVAL
INDICATES FIXTURES OR EQUIPMENT
TO BE REMOVED AND REINSTALLED
STAINLESS STEEL WALL FINISH TO REMAIN
REMOVE HOLLOW METAL FRAMES
REMOVE PAPER TOWEL DISPENSER AND SOAP DISPENSER AND RETURN TO
CUSTOMER
REMOVE AND REINSTALL KITCHEN FAUCET AT TEMPORARY KITCHEN
TWO MICROWAVES
THREE REFRIGERATORS
ONE DISHWASHER
1. PRIOR TO DEMOLITION, THE CONTRACTOR, AND HIS SUB-CONTRACTORS SHALL VISIT THE SITE AND FULLY
ACQUAINT THEMSELVES WITH EXISTING CONDITIONS FOR THE SITE. THE CONTRACTOR AND HIS
SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE REVIEW OF GENERAL NOTES, SPECIFICATIONS AND
ALL OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WHICH MAY NOT BE CALLED OUT IN THIS
PORTION OF THE CONSTRUCTION DOCUMENTS.
2. DIMENSIONS AND CONDITIONS OF EXISTING CONSTRUCTION SHOWN WERE OBTAINED FROM ORIGINAL
DRAWINGS AND FIELD OBSERVATIONS. THE CONTRACTOR SHALL PHYSICALLY MEASURE AND ASSESS ALL
EXISTING CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ITEMS
SHOWN ON THE DRAWINGS AND THOSE ACTUALLY EXISTING SHALL BE BROUGHT TO THE ATTENTION OF
THE CONTRACTING OFFICER. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BE AWARE THAT THESE
CONDITIONS MAY EXIST AND TO ALLOW FOR THEM IN THE CONSTRUCTION PROCESS.
3. THE CONTRACTOR SHALL PROTECT THE ACCESS PATH TO THE WORK AREA TO PREVENT DAMAGE OF THE
FACILITY - ANY DAMAGE TO ANY PART OF THE ADJACENT BUILDINGS OR SITE CAUSED BY THE
CONTRACTOR SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF AND AT NO COST TO THE
GOVERNMENT.
4. ALL MATERIALS RESULTING FROM DEMOLITION WORK SHALL BECOME THE PROPERTY OF THE
CONTRACTOR AND SHALL BE REMOVED FROM GOVERNMENT PROPERTY DAILY UNLESS OTHERWISE
DIRECTED SO AS TO NOT ALLOW ACCUMULATION INSIDE OR OUTSIDE THE BUILDING.
5. ALL NON-PAVED AREAS DISTURBED BY CONSTRUCTION SHALL BE RE-SEEDED BY THE CONTRACTOR.
LIMITS OF SEEDING ARE NOT SHOWN ON DRAWINGS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
REPAIR ALL AREAS DISTURBED BY CONSTRUCTION TO THE SATISFACTION OF THE GOVERNMENT.
6. THE CONSTRUCTION COVERED BY THESE PLANS SHALL CONFORM TO ALL APPLICABLE STANDARDS, CODES, AND ZONING ORDINANCES AS REQUIRED BY THE LOCAL GOVERNANCE, IN CURRENT USAGE. THE
SCOPE OF NEW CONSTRUCTION SHALL ALSO CONFORM TO THE ABA STANDARDS.
7. ANY ITEM WHICH IS TO REMAIN, WHICH MUST BE REMOVED IN ORDER TO INSTALL A NEW ITEM OR
REPLACEMENT ITEM, SHALL BE REINSTALLED UNLESS DAMAGED BY OR DURING THE REMOVAL
OPERATION. IF DAMAGED BY REMOVAL, A NEW ITEM OF THE SAME SIZE, SHAPE, AND QUALITY AS THE
EXISTING SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE
GOVERNMENT.
8. CONTRACTOR SHALL COORDINATE ALL DELIVERIES AND STORAGE OF MATERIALS WITH THE
GOVERNMENT.
9. DEMOLITION DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE INTENDED AS A GENERAL GUIDE TO THE
CONTRACTOR FOR DEMOLITION WORK. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE
THE EXACT DEMOLITION REQUIREMENTS WITH THE REQUIREMENTS OF THE NEW WORK AS SHOWN ON
THE DRAWINGS AND CONTAINED IN THE SPECIFICATIONS.
10.INSTALLATION OF NEW EQUIPMENT, MATERIALS OR FINISHES INDICATES CONTRACTOR'S ACCEPTANCE OF
SURFACES AND CONDITIONS WITHIN A PARTICULAR AREA. CONTRACTOR SHALL NOT BEGIN ANY WORK
UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.
11.PROTECT ADJACENT SURFACES FROM DAMAGE WHEN REMOVING PORTIONS OF EXISTING WORK NOTED
ON THESE DOCUMENTS.
12.PATCH ALL EXISTING WALLS AND FLOORS REMAINING SO AS TO PROVIDE A SMOOTH TRANSITION TO NEW
CONSTRUCTION.
13.PATCH ALL EXISTING WALLS AND FLOORS REMAINING WHERE EXISTING ITEMS OR ANCHORAGE DEVICES
ARE REMOVED TO MATCH SURROUNDING CONSTRUCTION AND FINISH.
14. ANY ALTERATION TO AN EXISTING RATED WALL SHOULD BE DONE TO ASSURE MAINTAINING ITS RATING AT
LEAST INDICATED OTHERWISE.
15.EXISTING FURNITURE DISASSEMBLY AND RELOCATION BEFORE WORK BEGINS, AND REASSEMBLY AND
REARRANGEMENT AFTER WORK IS COMPLETED SHALL BE BY OTHERS.
GENERAL NOTES
1. REFER TO CONSTRUCTION DRAWINGS FOR EXTENT OF DEMOLITION.
2. REFER TO ELECTRICAL AND MECHANICAL SHEETS FOR ADDITIONAL DEMOLITION.
3. DO NOT SCALE THESE DRAWINGS. FIELD VERIFY ALL DIMENSIONS, ELEVATIONS,
QUANTITIES, AND CONDITIONS.
4. REMOVE EXISTING GYPSUM BOARD FACING KITCHEN AREA WALLS UP TO 6" ABOVE
CEILING. WALLS WITH STAINLESS STEEL REMAIN THE SAME.
5. PATCH AND REPAIR EXISTING WALLS WHERE NEW WALLS INTERSECT TO PREPARE
FOR NEW PAINT AND CREATE SMOOTH TRANSITION BETWEEN NEW AND EXISTING
CONSTRUCTION.
6. REMOVE ALL KITCHEN CABINETS, SOFFIT ABOVE WALL CABINETS, COUNTERTOPS,
BACKSPLASH, ACOUSTIC CEILING TILES WITH GRID, FLOOR FINISH, COVE BASE, AND
WALLS AS INDICATED.
7. PATCH AND REPAIR EXISTING WALLS IN THE DINING ROOM ADJACENT TO THE KITCHEN
TO PREPARE FOR NEW PAINT.
8. REMOVE, REFURBISH, AND STORE RANGE TO BE REINSTALLED IN SAME LOCATION.
9. REMOVE, RELOCATE AND INSTALL EXISTING DISHWASHER, MICROWAVES, AND
REFRIGERATORS AT CUSTOMER INDICATED ROOM WITHIN THE BUILDING FOR A
TEMPORARY KITCHEN INSTALLATION.
10.REMOVE AND RELOCATE ALL ELECTRICAL, FIRE PROTECTION DEVICES, AND ANY
OTHER FIXTURE LOCATED ON WALLS TO BE DEMOLISHED.
11.DEMOLISH PLUMBING UNDER THE KITCHEN SINK INCLUDING GARBAGE DISPOSAL TO
BE REPLACED BY NEW - CAP OFF PLUMBING.
12.THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO INSURE AGAINST
DAMAGE TO EXISTING WORK TO REMAIN IN PLACE. ANY DAMAGE TO SUCH WORK
SHALL BE REPAIRED OR REPLACED AS APPROVED BY THE CONTRACTING OFFICER AT
NO ADDITIONAL COST TO THE GOVERNMENT.
13.CONSTRUCT DUST WALLS DURING DEMOLITION AND SANDING PROCEDURES AND ANY
OTHER OPERATIONS THAT GENERATE DUST TO AVOID CREATION OF A NUISANCE IN
THE SURROUNDING AREA. USE OF WATER WILL NOT BE PERMITTED.
14.THE CONTRACTOR SHALL ENSURE THAT STRUCTURAL ELEMENTS ARE NOT
OVERLOADED AND BE RESPONSIBLE FOR INCREASING STRUCTURAL SUPPORTS OR
ADDING NEW SUPPORTS AS REQUIRED AS A RESULT OF ANY CUTTING, REMOVAL, OR
DEMOLITION WORK PERFORMED.
REMOVE AND RELOCATE EQUIPMENT BOX INSIDE WALL CABINET
0 1' 2' 3'
SCALE: 3/4"=1'-0" (ANSI D)
EXISTING FLOOR TRANSITION TO REMAIN - LIMIT FOR FLOOR FINISH AND
ACOUSTIC CEILING TILE AND GRID REMOVAL
EXISTING FIRE EXTINGUISHER TO BE REMOVED AND REINSTALLED IN SAME
LOCATION
PLAN NORTH
INDICATES WALL FRAME TO REMAIN
DAY ROOM / DINING
ROOM
ROOM NAME AND NUMBER
| Sheets and Views |
| DEMOLITION PLAN |
| 2023-03-15T11:52:40-0500 | |
| BALES.JIMMIE.D.JR.1231309302 |
File details come from the government source that posted it. Updated .