DRAFT8457_a1-DEMOLITION PLAN.pdf

PDF 195 KB Posted

Attached to
Fort Leonard Wood MATOC IDIQ
Solicitation number
W911S7-23-R-0001
Issued by

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE:

D E

S I G

N E

D

C H

E C

K E

D

S U

B M

I T

T E

D

A P

P R

O V

E D

D A

T E

R E

V I S

I O

N S

D I R

E C

T O

R A

T E

O

F

P

U B

L I C

W

R

K S

F O

R

L

O

N A

R

W

O

D

M

I S

S O

U R

I

D R

A W

N

DATE:

PROJECT NO:

DRAWING NO:

SHEET OF

D A

T E

M A

D E

A P

P R

O V

E D

J

B a l e s

C

E

D B

A

L O

P E

Z

A

L O

P E

Z

J

B

A L E

S

A

L O

P E

Z

D E

M O

L I T

I O

N

P

L A

N

R E

N O

V A

K

I T

C H

N

A

B U

I L

D I N

G

AS SHOWN

07DEC22

M.0118951

FES 08369-1J

8457.12

A1 7

KITCHEN

N

DEMOLISH KITCHEN GYPSUM WALL BOARD, PORCELAIN FLOOR TILE AND BASE

DEMOLISH ALL WALL, BASE, AND TALL CABINETS

DEMOLISH COUNTERTOP AND BACKSPLASH

REMOVE COUNTERTOP, FINISHES AND GYPSUM BOARD ON HALF WALL.

REMOVE, REFURBISH, AND STORE TO REINSTALL RANGE - HOOD SHALL REMAIN

REMOVE, RELOCATE, CONNECT IN NEW LOCATION, AND REMOVE

TO CONNECT BACK IN KITCHEN AFTER REMODELING IS COMPLETED

REMOVE WALL COMPLETE EXCEPT AS INDICATED

DEMOLISH CHAIR RAIL

DEMOLISH WALL ABOVE COUNTERTOP AND LEAVE HALF WALL FRAME IN PLACE

REDUCED TO THE CABINET WIDTH

REMOVE SOFFIT ABOVE WALL CABINETS

DEMOLITION PLAN

A1

DEMOLITION KEYNOTES

DEMOLITION NOTES

DEMOLISH ACOUSTIC CEILING TILE SYSTEM AND FIXTURES WITHIN NEW

KITCHEN AREA ALL THE WAY TO WHERE FLOOR TILE CHANGES

REMOVE LIGHT FIXTURES UNDER WALL CABINETS

INDICATES HALF WALL FRAME TO REMAIN

LEGEND

INDICATES COMPLETE REMOVAL

INDICATES FIXTURES OR EQUIPMENT

TO BE REMOVED AND REINSTALLED

STAINLESS STEEL WALL FINISH TO REMAIN

REMOVE HOLLOW METAL FRAMES

REMOVE PAPER TOWEL DISPENSER AND SOAP DISPENSER AND RETURN TO

CUSTOMER

REMOVE AND REINSTALL KITCHEN FAUCET AT TEMPORARY KITCHEN

TWO MICROWAVES

THREE REFRIGERATORS

ONE DISHWASHER

1. PRIOR TO DEMOLITION, THE CONTRACTOR, AND HIS SUB-CONTRACTORS SHALL VISIT THE SITE AND FULLY

ACQUAINT THEMSELVES WITH EXISTING CONDITIONS FOR THE SITE. THE CONTRACTOR AND HIS

SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE REVIEW OF GENERAL NOTES, SPECIFICATIONS AND

ALL OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WHICH MAY NOT BE CALLED OUT IN THIS

PORTION OF THE CONSTRUCTION DOCUMENTS.

2. DIMENSIONS AND CONDITIONS OF EXISTING CONSTRUCTION SHOWN WERE OBTAINED FROM ORIGINAL

DRAWINGS AND FIELD OBSERVATIONS. THE CONTRACTOR SHALL PHYSICALLY MEASURE AND ASSESS ALL

EXISTING CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ITEMS

SHOWN ON THE DRAWINGS AND THOSE ACTUALLY EXISTING SHALL BE BROUGHT TO THE ATTENTION OF

THE CONTRACTING OFFICER. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BE AWARE THAT THESE

CONDITIONS MAY EXIST AND TO ALLOW FOR THEM IN THE CONSTRUCTION PROCESS.

3. THE CONTRACTOR SHALL PROTECT THE ACCESS PATH TO THE WORK AREA TO PREVENT DAMAGE OF THE

FACILITY - ANY DAMAGE TO ANY PART OF THE ADJACENT BUILDINGS OR SITE CAUSED BY THE

CONTRACTOR SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF AND AT NO COST TO THE

GOVERNMENT.

4. ALL MATERIALS RESULTING FROM DEMOLITION WORK SHALL BECOME THE PROPERTY OF THE

CONTRACTOR AND SHALL BE REMOVED FROM GOVERNMENT PROPERTY DAILY UNLESS OTHERWISE

DIRECTED SO AS TO NOT ALLOW ACCUMULATION INSIDE OR OUTSIDE THE BUILDING.

5. ALL NON-PAVED AREAS DISTURBED BY CONSTRUCTION SHALL BE RE-SEEDED BY THE CONTRACTOR.

LIMITS OF SEEDING ARE NOT SHOWN ON DRAWINGS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO

REPAIR ALL AREAS DISTURBED BY CONSTRUCTION TO THE SATISFACTION OF THE GOVERNMENT.

6. THE CONSTRUCTION COVERED BY THESE PLANS SHALL CONFORM TO ALL APPLICABLE STANDARDS, CODES, AND ZONING ORDINANCES AS REQUIRED BY THE LOCAL GOVERNANCE, IN CURRENT USAGE. THE

SCOPE OF NEW CONSTRUCTION SHALL ALSO CONFORM TO THE ABA STANDARDS.

7. ANY ITEM WHICH IS TO REMAIN, WHICH MUST BE REMOVED IN ORDER TO INSTALL A NEW ITEM OR

REPLACEMENT ITEM, SHALL BE REINSTALLED UNLESS DAMAGED BY OR DURING THE REMOVAL

OPERATION. IF DAMAGED BY REMOVAL, A NEW ITEM OF THE SAME SIZE, SHAPE, AND QUALITY AS THE

EXISTING SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE

GOVERNMENT.

8. CONTRACTOR SHALL COORDINATE ALL DELIVERIES AND STORAGE OF MATERIALS WITH THE

GOVERNMENT.

9. DEMOLITION DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE INTENDED AS A GENERAL GUIDE TO THE

CONTRACTOR FOR DEMOLITION WORK. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE

THE EXACT DEMOLITION REQUIREMENTS WITH THE REQUIREMENTS OF THE NEW WORK AS SHOWN ON

THE DRAWINGS AND CONTAINED IN THE SPECIFICATIONS.

10.INSTALLATION OF NEW EQUIPMENT, MATERIALS OR FINISHES INDICATES CONTRACTOR'S ACCEPTANCE OF

SURFACES AND CONDITIONS WITHIN A PARTICULAR AREA. CONTRACTOR SHALL NOT BEGIN ANY WORK

UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.

11.PROTECT ADJACENT SURFACES FROM DAMAGE WHEN REMOVING PORTIONS OF EXISTING WORK NOTED

ON THESE DOCUMENTS.

12.PATCH ALL EXISTING WALLS AND FLOORS REMAINING SO AS TO PROVIDE A SMOOTH TRANSITION TO NEW

CONSTRUCTION.

13.PATCH ALL EXISTING WALLS AND FLOORS REMAINING WHERE EXISTING ITEMS OR ANCHORAGE DEVICES

ARE REMOVED TO MATCH SURROUNDING CONSTRUCTION AND FINISH.

14. ANY ALTERATION TO AN EXISTING RATED WALL SHOULD BE DONE TO ASSURE MAINTAINING ITS RATING AT

LEAST INDICATED OTHERWISE.

15.EXISTING FURNITURE DISASSEMBLY AND RELOCATION BEFORE WORK BEGINS, AND REASSEMBLY AND

REARRANGEMENT AFTER WORK IS COMPLETED SHALL BE BY OTHERS.

GENERAL NOTES

1. REFER TO CONSTRUCTION DRAWINGS FOR EXTENT OF DEMOLITION.

2. REFER TO ELECTRICAL AND MECHANICAL SHEETS FOR ADDITIONAL DEMOLITION.

3. DO NOT SCALE THESE DRAWINGS. FIELD VERIFY ALL DIMENSIONS, ELEVATIONS,

QUANTITIES, AND CONDITIONS.

4. REMOVE EXISTING GYPSUM BOARD FACING KITCHEN AREA WALLS UP TO 6" ABOVE

CEILING. WALLS WITH STAINLESS STEEL REMAIN THE SAME.

5. PATCH AND REPAIR EXISTING WALLS WHERE NEW WALLS INTERSECT TO PREPARE

FOR NEW PAINT AND CREATE SMOOTH TRANSITION BETWEEN NEW AND EXISTING

CONSTRUCTION.

6. REMOVE ALL KITCHEN CABINETS, SOFFIT ABOVE WALL CABINETS, COUNTERTOPS,

BACKSPLASH, ACOUSTIC CEILING TILES WITH GRID, FLOOR FINISH, COVE BASE, AND

WALLS AS INDICATED.

7. PATCH AND REPAIR EXISTING WALLS IN THE DINING ROOM ADJACENT TO THE KITCHEN

TO PREPARE FOR NEW PAINT.

8. REMOVE, REFURBISH, AND STORE RANGE TO BE REINSTALLED IN SAME LOCATION.

9. REMOVE, RELOCATE AND INSTALL EXISTING DISHWASHER, MICROWAVES, AND

REFRIGERATORS AT CUSTOMER INDICATED ROOM WITHIN THE BUILDING FOR A

TEMPORARY KITCHEN INSTALLATION.

10.REMOVE AND RELOCATE ALL ELECTRICAL, FIRE PROTECTION DEVICES, AND ANY

OTHER FIXTURE LOCATED ON WALLS TO BE DEMOLISHED.

11.DEMOLISH PLUMBING UNDER THE KITCHEN SINK INCLUDING GARBAGE DISPOSAL TO

BE REPLACED BY NEW - CAP OFF PLUMBING.

12.THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO INSURE AGAINST

DAMAGE TO EXISTING WORK TO REMAIN IN PLACE. ANY DAMAGE TO SUCH WORK

SHALL BE REPAIRED OR REPLACED AS APPROVED BY THE CONTRACTING OFFICER AT

NO ADDITIONAL COST TO THE GOVERNMENT.

13.CONSTRUCT DUST WALLS DURING DEMOLITION AND SANDING PROCEDURES AND ANY

OTHER OPERATIONS THAT GENERATE DUST TO AVOID CREATION OF A NUISANCE IN

THE SURROUNDING AREA. USE OF WATER WILL NOT BE PERMITTED.

14.THE CONTRACTOR SHALL ENSURE THAT STRUCTURAL ELEMENTS ARE NOT

OVERLOADED AND BE RESPONSIBLE FOR INCREASING STRUCTURAL SUPPORTS OR

ADDING NEW SUPPORTS AS REQUIRED AS A RESULT OF ANY CUTTING, REMOVAL, OR

DEMOLITION WORK PERFORMED.

REMOVE AND RELOCATE EQUIPMENT BOX INSIDE WALL CABINET

0 1' 2' 3'

SCALE: 3/4"=1'-0" (ANSI D)

EXISTING FLOOR TRANSITION TO REMAIN - LIMIT FOR FLOOR FINISH AND

ACOUSTIC CEILING TILE AND GRID REMOVAL

EXISTING FIRE EXTINGUISHER TO BE REMOVED AND REINSTALLED IN SAME

LOCATION

PLAN NORTH

INDICATES WALL FRAME TO REMAIN

DAY ROOM / DINING

ROOM

ROOM NAME AND NUMBER

Sheets and Views
DEMOLITION PLAN
2023-03-15T11:52:40-0500
BALES.JIMMIE.D.JR.1231309302