PERPENDICULAR TO FURRING

PARALLEL WITH FURRING

RUNNER CHANNELS

AS SPECIFIED

CONT. DUST MEMBRANE

AS SPECIFIED. MINIMUM

WIDTH 5' SEAL LIPS

HAT-SHAPED FURRING

CHANNELS OR STUDS

WHERE SHOWN AND AS

SPECIFIED

GYP. BD. CLG.

MTL. CASING BEAD

DUST MEMBRANE

MTL. CASING BEAD

GYP. BD. CLG.

3/16" CONTRACTION JOINT

3/16" CONTRACTION JOINT

METAL STUD WALL

5/8" GYPSUM BOARD

# 8 HANGER WIRE

MAIN RUNNERS 1.12 LBS/FT

CROSS RUNNER 25 GA

SUSPENDED 5/8" GYPSUM

BOARD CEILING

GYPSUM BOARD BEAD

SEALANT - CONTROL JOINT

WALL ANGLE AT FLOATING

EDGE. 2" MIN. HORIZONTAL

LEG. TO RECEIVE HAT

CHANNELS. 3/4" CLEARANCE

8" MAX.

7/8" HAT FURRING CHANNELS

@ 24" O.C. MAX.

1 1/2" HOT ROLLING CHANNELS

NOTE:

ONE FLOATING END AND ONE FIXED END FOR EACH MAIN AND CROSS

RUNNERS. WALL ANGLE WITH #10 S.M.S. AT EACH STUD. #16 WIRE SADDLE

TIE TO MAIN RUNNER AT EACH CROSS RUNNER. 4-WAY 45° DIAGONAL #12

WIRE BRACING AT 12'-0" X 8'-0" WITH COMPRESSION STRUT.

@ INTERSECTIONS 4'-0" O.C.

@ 4'-0" O.C. MAX.

RUNNER CHANNELS

AS SPECIFIED

GYPSUM BOARD

HAT-SHAPED FURRING

CHANNELS WHERE

SHOWN AND AS SPECIFIED

SCREW AND TAPE AT

EXISTING SUSPENDED

ACOUSTICAL CEILING

METAL STUD WITH

BOTTOM TRACK

CROSS RUNNER FIXED

EXISTING CEILING TILES NEW GYPSUM BOARD CEILING

3-5/8" METAL STUD

BRACED TO

STRUCTURE ABOVE

TO STRUCTURE ABOVE

3-5/8" METAL STUD

AT NEW HARD CEILING

EDGE WHERE NO WALLS

TRANSITION MOLDING

WITH 3/8" SHADOW REVEAL

ENDS AND @ 12" O.C.

HANGER WIRE

AS SPECIFIED

SCALE:

D E

S I G

N E

D

C H

E C

K E

D

S U

B M

I T

T E

D

A P

P R

O V

E D

D A

T E

R E

V I S

I O

N S

D I R

E C

T O

R A

T E

O

F

P

U B

L I C

W

R

K S

F O

R

L

O

N A

R D

W

O

D

M

I S

S O

U R

I

D R

A W

N

DATE:

PROJECT NO:

DRAWING NO:

SHEET OF

D A

T E

M A

D E

A P

P R

O V

E D

J

B a l e s

C

E

D B

A

L O

P E

Z

A

L O

P E

Z

J

B

A L E

S

A

L O

P E

Z

R E

F L

E C

T E

D

C

E I L

I N

G

P

L A

N

A N

D

D

E T

A I L

S

R E

N O

V A

K

I T

C H

N

A

B U

I L

D I N

G

AS SHOWN

07DEC22

M.0118951

FES 08369-1J

8457.12

A3 7

KITCHEN

N

EXISTING FIRE SPRINKLERS TO REMAIN

A3

A.F.F.

ABOVE FINISHED FLOOR

O.C.

ON CENTER

REFLECTED CEILING PLAN

A3

INDICATES EXISTING SOUND RATED WALL

LEGEND

INDICATES NEW WALL

0 1' 2' 3'

SCALE: 3/4"=1'-0" (ANSI D)

NEW GYPSUM BOARD CEILING

EXISTING ACOUSTIC SUSPENDED CEILING TILE SYSTEM TO

REMAIN

NEW GYPSUM BOARD TO ACOUSTICAL CEILING TRANSITION

MOLDING

EXISTING GYPSUM BOARD TO ACOUSTICAL CEILING

TRANSITION MOLDING TO REMAIN

EXISTING GYPSUM BOARD CEILING TO REMAIN

NEW CONTRACTION JOINT BETWEEN EXISTING AND NEW

GYPSUM BOARD CEILING

CEILING KEYNOTES

PANTRY CLOSET

RECESSED LED FLUSH LIGHT

NEW LOCATION FOR EXISTING LIGHT FIXTURES

NEW FLUSH LED AREA KITCHEN LIGHT FIXTURES

UNDER-CABINET LED LIGHT

NEW LOCATION FOR EXISTING FIRE SPRINKLERS

EXISTING LIGHT FIXTURES TO BE RELOCATED

EXISTING 2' x 2' SUSPENDED ACOUSTIC CEILING TO

REMAIN

1. REFER TO ELECTRICAL AND MECHANICAL FOR ADDITIONAL

INFORMATION.

2. PROVIDE NEW GYPSUM BOARD CEILING AS INDICATED OVER

KITCHEN AREA TO MATCH EXISTING CEILING IN HEIGHT. PROVIDE

APPROPRIATE TRANSITION MOLDINGS TO ABUT NEW CEILING WITH

EXISTING. TAPE AND MUD OVER GYPSUM BOARD BEADS AND

MOLDINGS.

3. ALL EXISTING CEILING FIXTURES AND DEVICES SHALL REMAIN IN

SAME LOCATION UNLESS OTHERWISE INDICATED.

4. ALL CEILING FIXTURES OR DEVICES LOCATED ABOVE KITCHEN

AREA ON NEW HARD CEILING SHALL BE SHATTERPROOF,

ENCLOSED AND GASKETED, AND, ACCORDING TO REGULATORY

TERMS, NSF-RATED, SPLASH ZONE CERTIFIED, AND WET-LOCATION

RATED.

5. EXISTING LOCATION OF LIGHT FIXTURES, FIRE SPRINKLER HEADS,

FIRE ALARMS, MASS NOTIFICATION DEVICES, HVAC DIFFUSERS,

AND ANY OTHER DEVICE SHOWN ON DRAWINGS IS FOR REFERENCE

ONLY. ACTUAL LOCATION SHALL BE VERIFIED BY CONTRACTOR.

6. FIRE SPRINKLER HEAD RELOCATION SHALL BE PERFORMED IN

STRICT ACCORDANCE WITH THE LATEST VERSION OF NFPA 01,

NFPA 13, NFPA 101, IBC, AND UFC 3-600-01.

CEILING NOTES

EXISTING LIGHT FIXTURES TO BE REMOVED

PLAN NORTH

GYPSUM BOARD / HARD CEILING (GYP. BD. CLG.)

GYPSUM CEILING CONTRACTION JOINT DETAILS

NO TO SCALE

A3

GYPSUM CEILING DETAIL

NO TO SCALE

A3

CEILING TRANSITION

NO TO SCALE

A3

MAX.

MAXIMUM

MTL.

METAL

EXISTING FIRE SPRINKLERS TO BE RELOCATED

S.M.S.

SHEET METAL SCREW

MIN.

MINIMUM

A3

CEILING OPENING WHERE STOVE HOOD IS LOCATED

COFFEE STATION

DAY ROOM / DINING

2'X2' FLUSH MOUNTED ACCESS PANEL PAINT TO

MATCH CEILING SEE DETAIL 1/A4

AP

AP

Sheets and Views
REFLECTED CEILING PLAN